Alderlea T5 Operating instructions

Add to my manuals
24 Pages

advertisement

Alderlea T5 Operating instructions | Manualzz
IMPORTANT:
KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
Alderlea T5 Insert,
T5 Classic Insert
INSTALLATION AND OPERATING
INSTRUCTIONS
SAFETY NOTICE
If this stove is not properly installed, a house fire may result. For your safety,
follow the installation instructions. Contact local building or fire officials about
restrictions and installation inspection requirements in your area.
MODEL: ALT5 INSERT
SERIES - D
150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD. - 2014
ALT5.ASCINSB
5055.203-BAS
Contents
Maintenance Checks.......................................................................... 3
Maintenance ...................................................................................... 4
Baffle Removal ........................................................................... 4
Creosote ............................................................................................ 5
Formation and Need for Removal .............................................. 5
Chimney Fires ............................................................................ 5
In Case of a Chimney Fire ......................................................... 5
Avoiding a Chimney Fire ............................................................ 5
Operation ........................................................................................... 6
Wood Selection .......................................................................... 6
How to Test Your Wood .............................................................. 6
Lighting the Fire ......................................................................... 6
Normal Operation ...................................................................... 6
Restarting After Extended or Overnight Burns ........................... 7
More Wood, More Heat .............................................................. 7
Proper Draft ................................................................................ 7
Ash Removal .............................................................................. 7
Disposal of Ashes ...................................................................... 7
Blower ................................................................................................ 7
Blower Operation ....................................................................... 7
Electrical Supply ........................................................................ 7
Safety ................................................................................................. 8
Clearances ......................................................................................... 8
Masonry or Factory Built Fireplace ............................................ 8
Dimensions ........................................................................................ 10
Installation .......................................................................................... 11
Fireplace Specifications ............................................................. 11
Into a Masonry Fireplace ........................................................... 11
Full Flue Liner (Fig #2) ............................................................... 12
Combustion Air........................................................................... 12
Fan Speed Controller Relocation ............................................... 14
Fan Removal/Installation ............................................................ 16
Surround Assembly and Installation ........................................... 18
Replacement Parts, Alderlea T5 ........................................................ 19
Replacement Parts, Alderlea T5 Classic ............................................ 20
Troubleshooting .......................................................................... 21
Firebrick Installation ........................................................................... 22
Label .......................................................................................... 23
2
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
Maintenance Checks
Check the following parts for damage such as cracks, excessive corrosion, burned out sections and
excessive warping: (See website for descriptions and more detail)
Weekly:
- Firebrick - Visual, for cracking.
- Door Gasket - sagging, placement, damage.
Monthly
- Brick rail tabs and brick rails.
- Air riser tube in the back of the firebox.
- Back side of airwash chamber.
- Baffle locking pin.
- Boost tube cover.
When Cleaning the
Chimney System:
- Top baffle board/blanket.
- Baffle.
- Top heat shield and mounting bolt.
- Baffle Gasket.
- Brick Rails.
- Manifold.
**- Some warping of the baffle is normal(up to .65cm).
- Replace if the baffle has permanent warping greater than this or has cracking or breakage.
- Please contact your Dealer if you experience any of the damage listed above. Continuing to operate
your stove with broken parts may accelerate damage to other parts and may void your warranty
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
3
WARNING:
carefully.
Maintenance
1. Burn wood only, dry and well seasoned. The denser or heavier
the wood when dry, the greater its heat value. This is why
hardwoods are generally preferred. Green or wet wood will
cause a rapid buildup of creosote. If you feel it is necessary
to burn wet or unseasoned wood, do so only with the air inlet
set open enough to maintain a good strong fire and fairly high
chimney temperatures. Do not attempt to burn overnight using
green or wet wood. Wet wood can cause up to 25% drop in
heater output, as well as contributing significantly to creosote
buildup.
WARNING: Never use chemicals or any other volatile liquid
to start a fire. Do not burn garbage, or flammable fluids such
a gasoline, naptha, or engine oil. We strongly recommend
that smoke detectors be installed.
2. Remove ashes frequently. Embers can roll out the door and
create a fire hazard. Maintain a 25mm minimum ash base.
3. If glass becomes darkened through slow burning or poor
wood, it can readily be cleaned with any fireplace glass cleaner
when stove is cold. Never scrape with an object that might
scratch the glass. The type and amount of deposit on the
glass is a good indication of flue pipe and chimney buildup.
A light brown, dusty deposit that is easily wiped off usually
indicates good combustion and dry, well-seasoned wood and,
therefore, relatively clean pipes and chimney. On the other
hand, a black, greasy deposit that is difficult to remove is a
result of wet and green wood and too slow a burning rate.
This heavy deposit is building up at least as quickly in the
chimney.
Do not overtighten, tighten screws very
- Do not clean glass when hot
- Do not use abrasive cleaners on glass
6. The area where boost combustion air enters the firebox must
be kept clear of excessive ash buildup which will block air
flow. This area is at the front of the firebox.
7. Do not store wood within heater installation clearances, or
within the space required for fuel loading and ash removal.
Keep the area around the heater clean and free of all
combustibles, furniture, newspapers, etc.
8. If a plated door requires cleaning, use mild soap and water
only. Use of abrasive cleaners will void warranty.
9. Establish a routine for the fuel, wood burning and firing
technique. Check daily for creosote buildup until experience
shows how often you need to clean to be safe.
10. Be aware that the hotter the fire, the less creosote is deposited.
Weekly cleaning may be necessary in mild weather, even
though monthly cleaning is usually enough in the coldest
months when burning rates are higher.
11. Instruct all members of your family on the safe operation of
the heater. Ensure they have enough knowledge of the entire
system if they are expected to operate it. Stress the section
on chimney fires and the importance of following the steps
outlined in “In Case of Chimney Fire”.
Baffle Removal
The baffle should be removed from the fireplace to clean and
inspect the chimney liner.
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR INSULATION
REMOVED.
Baffle Assembly Removal
WARNING: Only use materials supplied by the manufacturer
when doing maintenance or replacements.
4. DOOR GASKET - The gasket used by Pacific Energy requires
only light pressure to seal. This will prolong seal life. It is
important that the door seal be maintained in good condition.
Periodically inspect seals and replace if necessary.
5. DOOR GLASS - Do not slam loading door or otherwise impact
glass. When closing door, make sure that no logs protrude
to contact the glass. If the glass gets cracked or broken,
it must be replaced before using the stove. Replacement
glass can be obtained from your Dealer. The size required
is 289mm x 438mm x 5 mm. Ceramic glass must be used.
Do not substitute with any other type.
To remove broken glass, undo the four retaining screws and
remove the clamps, noting position for re-assembly. Remove all
particles of glass. Be careful, as they are very sharp. Install new
glass complete with gasket. Replace clamps and screws.
4
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Remove retaining pin at the back top of the firebox, just under
the baffle. Lift baffle up and pull forward to disconnect from the
supply tube. Tilt baffle sideways to drop down and remove from
firebox.
Inspect gasket between baffle and supply tube. If necessary,
replace with gasket # 139.5 available from your nearest Pacific
Energy Dealer.
Re-install baffle assembly and insulation by reversing order.
It is recommended to inspect the liner and connector monthly
and to have the liner cleaned annually or more frequently
if required.
Cover the opening in the top of the rear upflow tube when
cleaning the chimney liner. If debris gets into the tube it can
cause the tube to prematurely burn out.
ALT5.ASCINSB 150714-24
Creosote
Formation and Need for Removal
When wood is burned slowly, it produces tar and other organic
vapours, which combine with expelled moisture to form creosote.
The creosote vapours condense in the relatively cool chimney flue
of a slow burning fire. As a result, creosote residue accumulates
on the flue lining. When ignited, this creosote makes an extremely
hot fire. The chimney connector and chimney should be inspected
at least once every two months during the heating season
to determine if a creosote buildup has occurred. If creosote
has accumulated, it should be removed to reduce the risk of a
chimney fire.
1. Highest smoke densities occur when a large amount of wood
is added to a bed of hot coals and the air inlet is closed. The
heated wood generates smoke, but without ample air, the
smoke cannot burn. Smoke-free, clean burning requires small
fuel loads, two or three logs at a time or 1/4 to 1/2 of a fuel
load and leaving the air inlet relatively wide open, especially
during the first 10 to 30 minutes after each loading, when most
of the smoke generating reactions are occurring. After 30
minutes or so, the air inlet can be turned down substantially
without excessive smoke generation. Wood coals create very
little creosote-producing smoke.
2. The cooler the surface over which wood smoke is passing,
the more creosote will be condensed. Wet or green wood
contributes significantly to creosote formation as the excess
moisture that is boiled off cools the fire, making it difficult for
the tars and gasses to ignite, thus creating dense smoke
and poor combustion. This moisture-laden smoke cools the
chimney, compounding the problem by offering the smoke
the ideal place to condense.
In Case of a Chimney Fire
1. Prepare to evacuate to ensure everyone’s safety. Have a
well understood plan of action for evacuation. Have a place
outside where everyone is to meet.
2. Close down the damper on stove.
3. Call local fire department. Have a fire extinguisher handy.
Contact your local fire authority for further information on how
to handle a chimney fire. It is most important that you have
a clearly understood plan on how to handle a chimney fire.
4. After the chimney fire is out, the chimney must be cleaned
and checked for stress and cracking before starting another
fire. Also check combustibles around chimney and the roof.
This should be done by a certified inspector/chimney sweep.
Avoiding a Chimney Fire
There are two ways to avoid chimney fires:
1. Do not let creosote build up to a point where a chimney fire
is possible.
2. Do not have fires in the heater that may ignite chimney fires.
These are hot fires, such as when burning household trash,
cardboard, Christmas tree limbs, or even ordinary fuel wood;
(eg. with a full load on a hot bed of coals and with the air inlet
wide open).
In summary, a certain amount of creosote is inevitable and must
be lived with. Regular inspection and cleaning is the solution.
The use of dry, seasoned wood and ample combustion air will
help to minimize the buildup.
Chimney Fires
The result of excessive creosote buildup is a chimney fire.
Chimney fires are dangerous. Chimney inside temperatures can
exceed 2000 degrees F. This causes much higher than normal
temperatures in the chimney and on its exterior surfaces thus
ignition of nearby or touching combustible material is more likely
during a chimney fire. Proper clearances are critical if such a
fire should occur.
Chimney fires are easy to detect; they usually involve one or
more of the following:
- Flames and sparks shooting out of the top of the chimney
- A roaring sound
- Vibration of the chimney
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
5
Operation
Wood Selection
This heater is designed to burn natural wood only. Higher efficiency
and lower emissions generally result when burning air-dried
seasoned hardwoods, as compared to softwoods or too green
or freshly cut hardwoods.
Wood should be properly air dried (seasoned) for six months or
more. Wet or undried wood will cause the fire to smoulder and
produce large amounts of creosote. Wet wood also produces
very little heat and tends to go out often.
DO NOT BURN:
-*Salt water wood
-Treated wood
-Wet or green wood
-Coal/charcoal
-*Garbage/Plastics
-Solvents
* These materials contain chlorides which will rapidly destroy
metal surfaces and void warranty.
Do not burn anything but wood. Other fuel, e.g. charcoal, can
produce large amounts of carbon monoxide, a tasteless, odourless
gas that can kill. Under no circumstances should you attempt to
barbecue in this heater.
How to Test Your Wood
Add a large piece of wood to the stove when it has a good, large
bed of coals. It is dry if it is burning on more than one side within
one minute. It is damp if it turns black and lights within three
minutes. If it sizzles, hisses and blackens without igniting in five
minutes it is soaked and should not be burnt.
WARNING: Do not use grates or andirons to elevate the fuel.
Burn directly on the firebricks. Replace broken or missing
bricks. Failure to do so may create a hazardous condition.
Your Pacific Energy heater is designed for maximum overall
efficiency at a moderate firing rate. Overfiring is hazardous and
a waste of fuel. Too slow a burn contributes to creosote buildup
and lowers combustion efficiency.
Lighting the Fire
WARNING: Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter fluid, or similar liquids to start
or ‘freshen up’ a fire in this heater. Keep all such liquids well
away from the heater while in use.
Normal Operation
1) Set air control to desired setting. If smoke pours down across
the glass (waterfall effect), this indicates you have shut the
control down too soon or you are using too low a setting. As
every home’s heating needs vary (i.e. insulation, windows,
climate, etc.), the proper setting can only be found by trial
and error and should be noted for future burns.
2) To refuel, adjust air control to "H" (high) position (pushed
to the far left) and give the fire time to brighten. Open door
slowly, this will prevent backpuffing.
3) Use wood of different shape, diameter and length (up to 19").
Load your wood endwise and try to place the logs so that air
can flow between them. Always use dry wood.
4) Do not load fuel to a height or in such a manner that would
be hazardous when opening the door.
5) For extended or overnight burns, unsplit logs are preferred.
Remember to char the wood completely on "H" (high) setting
before adjusting air control for overnight burn.
WARNING: Always keep loading door closed when burning.
If the door is left partly open, gas and flames may be drawn
out of the fireplace stove opening creating risks from fire and/
or smoke. This heater is not designed for open door burning,
unless a manufacturer supplied screen is used.
WARNING: This method is not a substitute for regular chimney
inspections and cleaning.
5) To achieve maximum firing rate, set control to “H” (high)
position (pushed to the far left). Do not use this setting other
than for starting or preheating fresh fuel loads.
DO NOT OVERFIRE THIS HEATER: Attempts to achieve heat
output rates that exceed heater design specifications can
result in permanent damage to the heater and chimney.
WARNING: No alteration or modification of the combustion
air control assembly is permitted. Any tampering will void
warranty and could be very hazardous.
Fig. # 31
Do not store/place wood or other combustibles within the
required clearances surrounding the unit.
Air Control
set to low.
6
1) Adjust air control to "H" (high) position (pushed to the far left)
and open door.
2) Place crumpled newspaper in the centre of the heater and
criss-cross with several pieces of dry kindling. Add a few
small pieces of dry wood on top.
3) Ignite the paper and close the door.
4) After the fire has established itself, open the door and add a
few small logs. Close door.
5) Begin normal operation after a good coal base exists and
wood has charred.
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
Restarting After Extended or Overnight Burns
1) Open door and rake hot embers towards the front of the heater.
Add a couple of dry, split logs on top of embers, close door.
2) Adjust air control to “H” (high) position (pushed to the far left)
and in just a few minutes, logs should begin burning.
3) After wood has charred, reset air control to desired setting.
4) When burning at a slow rate for extended periods, occasionally
maintain a strong fire under supervision for a couple of hours
to relieve firebox and chimney deposits as well as any of the
deposits on the glass.
More Wood, More Heat
Seasoned wood has approximately 7500 BTU’s per pound. If
you put 10 pounds of wood in your stove for an eight hour burn
the wood will be producing 9375 BTU’s per hour. (7500 BTU x
10 lbs / 8 hrs. = 9375 BTU’s per hr.). If you put 20 lbs of wood in
your stove for an eight hour burn you will get 18,750 BTU’s per
hr. (7500 BTU x 20 lbs / 8 hrs. = 18,750 BTU’s per hr.). This is
only an example and is based on 100% efficiency. In reality, your
stove should perform in the 70% efficiency range.
Experience will give you the right settings for proper combustion
and efficient burning. Remember, the air inlet setting is affected
by variables such as type of wood, outside temperature, chimney
size and weather conditions. With practice, you will become
proficient in operating your heater and will obtain the performance
for which it was designed.
Proper Draft
1) Draft is the force which moves air from the appliance up
through the chimney. The amount of draft in your chimney
depends on the length of the chimney, local geography, nearby
obstructions and other factors.
2) Too much draft may cause excessive temperatures in the
appliance. An uncontrollable burn or a glowing red stove part
or chimney indicates excessive draft.
3) Inadequate draft may cause backpuffing into the room and
plugging of the chimney. Smoke leaking into the room through
appliance and chimney connector joints indicates inadequate
draft.
Blower
The Alderlea Insert comes equipped with twin variable speed
circulating air blowers. The blower system is thermostatically
controlled for automatic operation, as as well manually with a
convenient bypass switch.
Blower Operation
Automatic: To operate the blowers automatically, push the rocker
switch to the “OFF” position and set the fan speed control to a
desired setting.
This will allow the blowers to turn on automatically once the Insert
has come up to operating temperature. It will also shut the blower
off after the fire has gone out and the appliance has cooled to
below a useful heat output range.
Manual: To manually operate the blowers, push the rocker switch
to the “ON” position and set the fan speed control to a desired
setting. This will bypass the temperature switch and allow full
control of the blower.
Suggested settings:
- Combustion air control setting of “L” (low) position (pushed
to the far right), operate blower speed control on “Low”.
- Combustion air control set at anything above “L” (low),
operate blower speed control at desired setting.
Electrical Supply
Circulating air blower electrical rating; 115V, 60 Hz, 1.1 A. For
your protection against shock hazard, use only a properly
grounded outlet that will accept a three-pronged plug. Do not cut
or remove the grounding prong. Do not route power cord under
unit. Power cord must be routed to avoid contact with any hot or
sharp surfaces.
All electrical connections to and within an appliance shall be in
accordance with the requirments od AS/NZS 3000, AS/NZS 3100
or ER 93 and the regulatory auhtority as appropriate.
Ash Removal
Fig. # 32
Whenever ashes get 3 to 4 inches deep in your firebox, and when
fire has burned down and cooled, remove excess ashes. Leave
an ash bed approximately 1 inch deep on the firebox bottom to
help maintain a hot charcoal bed.
Control
Box
Electrical Rating : 115 V, 60 Hz, 1.1A
Blowers
Disposal of Ashes
Ashes should be placed in a metal container with a tight fitting
lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible
materials, pending final disposal. If the ashes are disposed of
by burial in soil or otherwise locally dispersed, they should be
retained in the closed container until all cinders have thoroughly
cooled. Other waste should not be placed in this container!
ALT5.ASCINSB 150714-24
Thermo
Switch
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
7
Safety
Clearances
Please read this entire manual before installation Masonry or Factory Built Fireplace
and use of this wood burning insert. Failure to follow
The minimum required clearances to surrounding combustible
these instructions could result in property damage, materials when installed into a masonry or factory built fireplace
bodily injury or even death.
are listed below and in figure #1.
We strongly recommend that smoke detectors be installed. If
smoke detectors have been previously installed, you may notice
that they are operating more frequently. This may be due to curing
of stove paint or fumes caused by accidentally leaving the fire
door open. Do not disconnect the detectors. If necessary, relocate
them to reduce their sensitivity.
SAFETY NOTICE: If this stove is not properly installed, a
house fire may result. For your safety, follow the installation
directions. Consult local building or fire officials about
restrictions and installation inspection requirements in
your area.
Minimum Clearances to Combustibles
(Measured From Insert Door and Decorative Top)
Adjacent Sidewall ....................300mm.
Mantel ......................................600mm.
Top Facing ...............................600mm.
Side Facing ............................. 300mm.
CAUTION: Unit hot while in operation. Parts of the appliance,
especially the external surfaces, will be hot to touch when
in operation. Keep children, clothing and furniture away.
Contact may cause skins burns.
Fig. # 1
Mantel or Top Facing
Side Facing
600mm
300mm
300mm
nt
ace
ll
Wa
j
Ad
Fireplace
Hearth
51mm
8
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
*
Fireplace hearth requirements: (Measured without the insert)
The non-combustible fireplace hearth must be raised 50mm above an adjacent combustible floor and extend 400mm in front
and 200mm beyond each side of the existing fireplace opening. A non-combustible hearth that extends a minimum 600mm in
front of the fireplace opening may be flush to an adjacent combustible floor.
MINIMUM FIREPLACE
OPENING AND HEARTH
DIMENSIONS
400mm
622mm
533mm
607mm
457mm
Non-combustible fireplace
hearth
464mm
200mm
200mm
*
50mm
50mm
**
Ember protection:
Combustible floor in front of the fireplace insert must be protected from hot embers by non-combustible material extending
400mm to the firing side from the door and 200mm to other sides of the unit.
MINIMUM EMBER
PROTECTION
DIMENSIONS
572mm
Non-combustible fireplace
hearth
**
400mm
Non-combustible floor
covering
51mm
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
9
Dimensions
ALT5 INSERT &
ALT5 CLASSIC INSERT
WITH REGULAR SURROUND
WITH OVERSIZED SURROUND
867mm
772mm
746mm
841mm
1.08m
1.08m
448mm
241mm
530mm
546mm
448mm
270mm
606mm
854mm
10
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
721mm
ALT5.ASCINSB 150714-24
Installation
Warning:
Under no circumstances is this heater to be installed in a makeshift
or “temporary” manner. It may be fired only after the stove is installed
properly.
DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR
DISTRIBUTION DUCT.
Fireplace Specifications
Your fireplace is required to have the following minimum sizes:
WIDTH (at front)
622mm
WIDTH (at rear)
610 mm
HEIGHT
533 mm
DEPTH
464 mm
Chimney height 4.5m (minimum)
Into a Masonry Fireplace
Outside combustion air or fresh air into the room may be required in
your area, consult local building codes (see Combustion Air section).
WARNING: THE APPLIANCE AND FLUE-SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIRMENTS OF THE RELEVANT BUILDING
CODE OR CODES
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS
OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY
AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE
BY A COMPLIANCE PLATE WITH THE MARKING ‘TESTED TO
AS/NZS 4013’.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR
COMPLIANCE WITH AS/NZS 4013.
Inspect your fireplace for cracks, loose mortar or other physical
defects. If repairs are required, they should be completed before
installing your insert.
The fireplace chimney must be suitable for wood burning use.
Check for creosote build up or other obstructions, especially if it
has not been in use for some time - have chimney swept.
The existing fireplace damper is to be locked open or removed
completely.
The services of a competent or certified installer are strongly
recommended to install or commission this installation.
WARNING: Do not remove bricks or mortar from your
existing fireplace.
Exception: Masonry or steel, including the damper plate, may
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE
DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT
IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN
THE FIRST INSTANCE.
CAUTION: CRACKED OR BROKEN COMPONENTS, e.g. GLASS
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSAFE.
WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS
NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.
CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH
A CRACKED GLASS.
CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND
OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.
CAUTION:THE USE OF SOME TYPES OF PRESEVATIVE-TREATED
WOOD AS A FUEL CAN BE HAZARDOUS.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVICING ANOTHER APPLIANCE.
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
11
be removed from the smoke shelf and adjacent damper frame if
necessary to accommodate a chimney liner, provided that their
removal will not weaken the structure of the fireplace and chimney,
and will not reduce protection for combustible materials to less
than that required by the National Building Code.
The Insert must be installed in accordance with local and or
national building codes. The two methods of flue connection
that are acceptable in most areas are:
Fig. # 2
Full Flue Liner
Rain Cap
Full Flue Liner: (Fig.2) where a stainless steel rigid or flexible
liner extends from the Insert flue collar to the top of the chimney.
For difficult installations, this insert is approved for use with
a SPND.3OFFSETA - 3” flue offset box. Only this offset box
is approved for use with this insert. The use of any other
offset box may cause a hazard and/ or void any warranty.
Stainless Steel
Rigid or Flex Liner
Full Flue Liner (Fig #2)
This fireplace insert must be installed with a continuous liner of
150mm diameter extending from the fireplace insert to the top
of the chimney.
Mantel or
Top Facing
Consult your local Dealer about relining your fireplace chimney.
1) Measure the chimney height from the top of the existing flue
to the floor of the hearth. This will allow extra length of liner
for flashing and rain cap.
2) Feed the stainless steel liner from the top of the chimney,
through the damper area and into the fireplace cavity.
3) Attach a stove connector to the bottom of the liner, as per the
instructions provided with the chimney liner.
4) To mount optional rear leveling leg bolts, prop unit up to access
threaded inserts under rear of unit. Thread supplied bolts into
inserts, set depth to correspond to depth of fireplace drop.
5) Push the Insert into position inside the fireplace and attach
the connector to the stove collar and secure with screws.
Use the rear adjusting legs to level the Insert.
Note: To access the holes for securing connector to the stove
collar, remove the top front casing.To remove, undo the screws
located on both sides of the top front(Fig #3) then pull casing
toward you and up. Reverse these steps to install casing top.
If it is necessary to get access to the connector pipe through
the flue outlet of the Insert, the baffle can be removed (see
Baffle Removal section).
6) Measure, trim and shape a top flashing to fit the existing
chimney flue. Plan for a 25mm to 38mm overlap on each
side. Place flashing over top of the liner and seat firmly
against the tile.
7) Screw flashing collar to liner. Caulk gap around flashing with
RTV silicone.
8) Attach a rain cap to the end of the liner. A storm collar should
be used. (Follow vent manufacturers instructions.)
Fig. # 3
SCREWS
Combustion Air
Consult local building codes regarding combustion air supply.
Intake or combustion air can be supplied to the Insert in one of
12
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
Chimney and Connector
WARNING: INSTALL CHIMNEY AND ALL COMPONENTS OF CHIMNEY SYSTEM
ACCORDING TO CHIMNEY MANUFACTURER’S INSTRUCTIONS.
Connect to a listed chimney complying with the requirements of AS/NZS2918/2001 and a
chimney suitable for use with solid fuel that is lined and in good condition and meets local
building codes. The chimney flue size should be the same as the stove outlet for optimal
performance. Reducing or increasing the flue size may adversely affect stove performance.
Chimney flue exit is to be minimum 1000mm above roof and 600mm above highest projection within 3000mm. The installation must meet all local codes. Do not connect this unit to
a chimney flue serving another appliance. Minimum system height is 4600mm (measured
from base of appliance).
Fig. # 4
Installation Procedure
1.
Install all components to the chimney manufacturer's installation requirements. (Outside
combustion air may be required, consult local building codes. See Combustion Air
section on page 12.)
2. Installed with the crimped or male ends pointing down. This will carry any liquid creosote
or condensation back into the stove.
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
13
Fig. # 6
two ways:
1) Outside air (O/A) supply: Remove cover from ash clean
out in existing fireplace. Place a rodent screen in place of
the cover. Install the Insert as described in the installation
section, making sure not to cover the opening of the air inlet.
When installation is complete, seal surround to fireplace and
anywhere else air may enter. This will ensure combustion air
is drawn from outside the house and into the 229mm x 51mm
intake at the lower rear of the appliance.
2) Room air supply: Install the Insert as described in the
installation section. When the installation is complete, do not
seal surround to fireplace. This will allow enough combustion
air to enter the fireplace cavity and the Insert. The knockouts
in the casing sides and the O/A cover can be removed to
supplement air supply (Fig.6 & 7). Once removed, combustion
air is drawn from the room into the lower front of the Insert.
O/A Cover
Removal: The O/A cover should be removed prior to installation.
For better access, tip the Insert onto its back.
1. Using a 5/16” wrench, remove the screw securing the O/A
cover to the firebox (Fig. #5 & 6).
This unit is not designed to be operated with the firing door open. In
addition to the obvious hazard of sparks landing on combustibles,
an open fire door will cause the heater to draw air from the living
space and possibly cause suffocation.
The living space around the heater must be well ventilated with
good air circulation. Anything that may cause a negative pressure
can cause gases or fumes to be pulled into the living area.
Fan Speed Controller Relocation
The fan speed controller is factory installed under the ash lip
on the right hand side. If required, it can be relocated to the left
Fig. # 5
Fig. # 7
O/A Cover Screw
Remove Knockout
14
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
2) Remove Top(A) and Shields(B). (Fig. #8)
Fig. # 10
3) Remove Surround Top and Sides from Packaging.
F
4) Remove the surround brackets from the stove(Fig. #9) and
attach to the Surround sides as shown in Fig. #10. Use the
bolts and washers in the mounting hardware kit found with
the Surround Top. (Fig #10)
5) Lay Surround sides flat on floor and align with Surround
Top(H). Square the surround by aligning edges(I) on each
side. Fasten bolts (J) to attach bracket.(Fig. #11)
F
F
NOTE: If mounting an Oversized Surround (not shown), use
mounting holes (K) to attach.(Fig. #11)
6) Attach surround to firebox by aligning with bracket studs (L)
then fasten with washers and nuts (M) on each side.
(Fig. #12)
7) Install fan shield as shown in Fig. #13. Be sure to place the
F
Fig. # 8
Fig. # 11
H
A
K
B
I
J
K
J
I
air inlet opening against the surround side.
8) Install the cast decorative top by tilting it at a slight angle,
Fig. # 12
Fig. # 9
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
15
sliding it under the surround top, and settling it over the fan
shields. (Fig #14).
9) Be sure to engage fan shield tops in the slots on the underside
of the cast decorative top. (Fig. #15)
Fig. # 15
SLOT
Fan Removal/Installation
1) Remove Decorative Top and both Fan shields as specified in
“Fan Speed Control Relocation” section on page 11.
Fig. # 13
AIR INLET
SURROUND
SIDE
2) Disconnect fan wires as shown in Fig #16 from appropriate
fan that is being replaced. Remove Thermal switch if needed.
(Fig #17)
3) Remove the two screws securing the fan bracket to the stove
using a 7/16” socket or wrench. Reverse steps 1&2 to install
new fan.(Fig #17)
Fig. # 14
Fig. # 16
Fig. # 17
SCREWS
THERMAL
SWITCH
16
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
side by following the instructions below. To make this as easy
as possible, it is suggested that this be done prior to fitting the
surround and installation into the fireplace:
1) Remove the decorative top by tilting up slighty and lifting
away from the unit. (Fig #18)
Fig. # 22
Fig. # 18
5) Loosen the screws on the wire support tabs and turn to remove
the wires (Fig #23).
BOLTS
2) Lift up on each fan shield and remove. Set aside to prevent
damage. (Fig #19)
Fig. # 23
SCREWS
Fig. # 19
FAN SHIELD
Lift Up
3) Disconnect the wires from the fans, Left & Right Side(Fig #20).
Unscrew thermal snap switch leaving the wires connected(Fig
#21). Take note of where the wires are routed and secured.
They must be positioned correctly to avoid damage.
Fig. # 20
Fig. # 24
Fig. # 21
`
4) Loosen the two bolts that secure the ash lip to the firebox
(Fig #22), carefully lift up the ash lip and remove from the
firebox.
ALT5.ASCINSB 150714-24
6) Remove the two screws securing the speed controls assembly
to the ash lip (Fig #24).Remove cover plate on opposite
side.
7) Remove the control assembly from the ashlip bracket on the
right hand side. Flip it over and reattach on the left hand side
of the ashlip (Fig #25).SCREWS
Use the upper screw holes for best
alignment.
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
17
is important to prevent damage to wires.
Surround Assembly and Installation
1) Remove crate and all plastic packaging.
Fig. # 25
SPEED CONTROL
ASHLIP BRACKET
Fig. # 28
8) Route cable from speed control to fan and reattach wire support
tabs on the underside of the ash lip. Note wire positions.
(Fig.26 & Fig.27)
9) Reconnect the wires to the fans (Fig.28) and re-attach thermal
snap switch (Fig.29). Refit ash lip, sides and top. Ensure that
the power cable is correctly routed through the surround and
it is not touching the firebox side (Fig #30). Wire placement
Fig. # 26
WIRE SUPPORT TABS
Fig. # 29
THERMAL
SWITCH
Fig. # 27
18
Fig. # 30
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
Replacement
Parts, Alderlea T5
(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)
ITEM DESCRIPTION
PART NO.
1............Regular Surround ............................. ALT5.SMBKA
..............Surround, Black Enamel...................... ALT5.PBKA
..............Surround, Majolica Brown Enamel ...... ALT5.PBNA
..............Oversized Surround .................... ALT5.SMBKOSA
..............O/S Surround, Black Enamel ......... ALT5.PBKOSA
..............O/S Surround, Majolica Brown Enamel ..................
ALT5.PBNOSA
2............Fan Shield, Left ....................................5037.47221
..............Fan Shield, Left Black Enamel ........5037.47221BK
..............Fan Shield, Left Majolica Brown Enamel ...............
..............5037.47221BN
3............Cast Decorative Top ...............................5037.4725
..............Decorative Top, Black Enamel ...........5037.4725BK
..............Decorative Top, Majolica Brown Enamel ................
..............5037.4725BN
4............Casing Top .......................................... SPND.4545
5............Fan Shield, Right ..................................5037.47222
..............Fan Shield, Right Black Enamel ......5037.47222BK
..............Fan Shield, Right Majolica Brown Enamel .............
..............5037.47222BN
6............Ash Lip Assembly ......................... ALT5.50374723
..............Ashlip Assy, Black Enamel .....ALT5.P50274723BK
..............Ashlip Assy, Majolica Brown Enamel ......................
..............ALT5.P50374723BN
7............Door Catch .................................................... 4740
ITEM DESCRIPTION
PART NO.
*8 ..........Glass Clamp Set (4 pc.) ........................... 4720.01
*9 ..........Replacement Glass (c/w Tape) .......... 5034.20806
10 ..........Door Casting, Black....................... ALT5.50374722
..............Door Assy, Black Enamel ........ ALT5.P472201BKA
..............Door Assy, Majolica Brown Enamel ........................
..............ALT5.P472201MBA
11 ..........Door Handle Assembly ................. ALDR.50380GR
*12 ........Flame Shield ........................................WINS.4513
*13 ........Replacement Baffle Kit ................... SSER.DBAKIT
*14 ........Brick Rail, Set............................... SSER.RAILSET
15 ..........Firebrick Set ..................................... BRIC.SSERA
*16 ........Boost Manifold ............................................... 4105
*17 ........O/A Cover......................................................... 514
*18 ........Air Shutter Assembly ............................WIND.4531
19 ..........Blower (RHS) ............................................ 5024.54
..............Blower (LHS) ............................................. 5024.53
20..........Blower Mounting Bracket ............................... 4541
21..........Control Box Assembly ......................... SPND.4583
Parts may be ordered from your nearest Pacific Energy
dealer. Contact Pacific Energy for the location of the dealer
nearest you.
*NOT SHOWN
1
Fig. # 33
4
1
3
2
20
7
1
19
5
20
15
6
19
21
11
10
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
19
Replacement
Parts, Alderlea T5 Classic
(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)
ITEM DESCRIPTION
PART NO.
1............Surround, Black Enamel....................ALT5.SPBKA
..............Surround, Majolica Brown Enamel ....ALT5.SPBNA
..............O/S Surround, Black Enamel .......ALT5.SPBKOSA
..............O/S Surround, Majolica Brown Enamel ..................
ALT5.SPBNOSA
2............Fan Shield, Left Black Enamel .... ALT5.P4728BKA
..............Fan Shield, Left Majolica Brown Enamel ...............
..............ALT5.P4728BN
3............Decorative Top, Black Enamel ..... ALT5.P4725BKA
..............Decorative Top, Majolica Brown Enamel ................
..............ALT5.P4725BN
4............Casing Top .......................................... SPND.4545
5............Fan Shield, Right Black Enamel .. ALT5.P4729BKA
..............Fan Shield, Right Majolica Brown Enamel .............
..............ALT5.P4729BN
6............Ashlip Assy, Black Enamel .....ALT5.P50274723BK
..............Ashlip Assy, Majolica Brown Enamel ......................
..............ALT5.P50374723BN
7............Door Catch .................................................... 4740
ITEM DESCRIPTION
PART NO.
*8 ..........Glass Clamp Set (4 pc.) ........................... 4720.01
*9 ..........Replacement Glass (c/w Tape) .......... 5034.20806
10 ..........Door Assy, Black Enamel ........ ALT5.P472201BKA
..............Door Assy, Majolica Brown Enamel ........................
..............ALT5.P472201BN
..............Clearview Door.......................................................
..............Black Enamel .......................... ALT5.P472202BKA
..............Majolica Brown, Enamel .......... ALT5.P472202BNA
11 ..........Door Handle Assembly ................. ALDR.50380GR
*12 ........Flame Shield ........................................WINS.4513
*13 ........Replacement Baffle Kit ................... SSER.DBAKIT
*14 ........Brick Rail, Set............................... SSER.RAILSET
15 ..........Firebrick Set ..................................... BRIC.SSERA
*16 ........Boost Manifold ............................................... 4105
*17 ........O/A Cover......................................................... 514
*18 ........Air Shutter Assembly ............................WIND.4531
19 ..........Blower (RHS) ............................................ 5024.54
..............Blower (LHS) ............................................. 5024.53
20..........Blower Mounting Bracket ............................... 4541
21..........Control Box Assembly ......................... SPND.4583
22..........Crown Assembly, Black ..........ALT5.P50374724BK
..............Crown Assembly, Brown .........ALT5.P50374724BN
*NOT SHOWN
1
Fig. # 34
4
1
3
2
20
7
1
19
5
22
20
15
6
19
21
11
10
20
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
ALT5.ASCINSB 150714-24
Troubleshooting
Problem
Cause
Cure
Excessive Creosote
Buildup
1) Wood is too wet
- Use dry wood
2) Turning down air control
too soon
- Do not turn down until:
a) there is a good bed of coals
b) the wood is charred
3) Draft too low
- Improper chimney height and/or diameter
- Chimney plugged or restricted, check flue
- Provide outside air for combustion
Glass is Dirty
Low Heat Output
1) See 1, 2, and 3 above
2) Door Gasket leakage
- Replace gasket
- Check latch
1) Wood is wet
- Use dry wood
2) Fire too small
- Build a larger fire
3) Area too large
4) Poor insulation or open concrete
Won't Burn Overnight
Stove Won't Burn
21
ALT5.ASCINSB 150714-24
1) Air control set too high
- Set control lower
2) Not enough wood
- Unsplit wood is preferred for overnight burns
3) Possible air leak
- Door gasket needs changing
1) Combustion air supply
is blocked
- Check outside air supply for obstructions
(see Combustion Air section)
2) Draft too low
- Chimney plugged or restricted
Inspect and clean
- Chimney oversized or otherwise unsuitable
Consult Dealer
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
21
Firebrick Installation
Alderlea T5 Insert
This package contains 18 full-size firebricks, as well as 1 cut-size brick.
With the heater in the upright position, install firebricks as follows:
- Place firebricks on the bottom of the heater first. Total of 7 full-size and 1cut
brick.
- Next, install the side firebricks, 4 full-size each side.
- Lastly, install 3 full-size firebricks against the rear wall.
ITEM
A
B
22
SIZE
230 mm x 115 mm x 32 mm
184 mm x 115 mm x 32 mm
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
PART NUMBER
N. America
5096.99
245.0
ALT5.ASCINSB 150714-24
Label
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
Model: ALDERLEA T5
Series: D
Type: FIREPLACE INSERT
Tested by: HRL TECHNOLOGY PTY LTD
TRAMWAY ROAD, MORWELL, VICTORIA
Tested to: AS/NZS 4013:1999
Test report no: HCMG/13/048
1/OCT/2013
MAXIMUM AVERAGE HEAT OUTPUT BURNING
HARDWOOD - 10.0 kW
OVERALL AVERAGE EFFICIENCY BURNING
HARDWOOD - 67%
WHEN TESTED IN ACCORDANCE WITH
AS/NZS 4012
Distributed by: PIVOT STOVE & HEATING CO
234-238 MOORABOOL STREET, GEELONG VIC 3220
pivotstoves.com.au
050914
MADE IN CANADA
5050.44AS
The certfication label is located on the left side casing of the insert.
CERTIFICATION
LABEL
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
23
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
www.pacificenergy.net
Technical Support: 1-250-748-1184
2975 Allenby Rd., Duncan, B.C. V9L 6V8
Printed in Canada
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement