My Home My Home - Daikin interface interface

My Home My Home - Daikin interface interface
Open Web Net My Home – Daikin Interface
My Home - Daikin interface
www.myopen
www.myopen-legrandgroup.com
1
Open Web Net My Home – Daikin Interface
Document History
Version
1.0.0
Date
11/02/2013
Author
My Open Staff-JR
Index
Introduction .......................................................................................................................... 3
What we are going to do ...................................................................................................... 4
Building the set up ............................................................................................................... 6
Configuration ....................................................................................................................... 7
MH200N....................................................................................................................... 7
346001 ....................................................................................................................... 11
C9451 ........................................................................................................................ 11
L4684 ......................................................................................................................... 11
3456 ........................................................................................................................... 18
CoolMaster ................................................................................................................ 22
DS1206 ...................................................................................................................... 26
Test .................................................................................................................................... 31
Licenses............................................................................................................................. 34
Disclaimer .......................................................................................................................... 34
www.myopen-legrandgroup.com
2
Open Web Net My Home – Daikin Interface
Introduction
This tutorial pretend to connect My Home system to a Daikin CoolMaster interface. This
way we are going to be able to control Daikin systems using the Touch Screen of a My
Home system.
***This is a small tutorial full of pictures you can read it in a few minutes.
www.myopen-legrandgroup.com
3
Open Web Net My Home – Daikin Interface
What we are going to do
We are going to build a basic system using several My Home devices to connect and
control a CoolMaster Daikin interface unit. The CoolMaster is a really useful interface that
can control to a Daikin HVAC system using a RS232 protocol.
Steeps
1. – Building the setup
2. - Configuration all the devices in the set up
3. – Run some tests
WHAT YOU WILL NEED
1. – Any My Home Gateway like MH200N or F454 this tutorial uses the MH200N
2. – Any Power Source like E49 for SCS Bus, or 346020 for MH200N this tutorial use the
346020
3. - Bticino TouchScreen H4890
4. - IRSplit Interface 3456 one for each internal unit we are controlling, in this case we are
using 3 off them.
5. - CoolMaster 1000D Daikin VRV Supply by Cool Automation
6. - DS1206 supply by Tibbo Technology, this device need also a power source supplied
by third party
7. - USB to RS232 converter, you need this only in case your PC don’t have one of them,
this device is used to simulate some internal units in the CoolMaster if you have the actual
units connected to the CoolMaster you probably won’t need this device.
8. - Several hardware, Serial cable, Network cable, power supply etc.
Abstract
Basically we need to translate Open Web Net messages into RS232 messages for
CoolMaster in a reliable way to control the Daikin system. As you know Open Web Net is
based on IP protocol, so we need to translate from IP to RS232.
www.myopen-legrandgroup.com
4
Open Web Net My Home – Daikin Interface
Description of each component
MH200N or any other gateway is used to maintain a TCP/IP connection in a public open
language like Open Web Net, this way we can hear any message from the internal BTicino
Bus and translate into TCP/IP language in this case Open Web Net.
346020 this is the power supply of the MH200N and also is needed to be the bus supply of
My Home system. Also any power supply will be fine.
C9451 This is a Ethernet Switch in this case provided by BTicino no need any
configuration.
H4890 is the small My Home Touch Screen, the human interface of My Home System, is
used to control the VRV System from the standard pages provided to manage generic IR
Air Condition Splits. It’s also possible to use the big My Home Touch Screen item H4690.
3456 This device translate the commands from the Touch Screen into the IRSplit protocol,
The IR signal is not going to be used, but it's used to simulate the command received from
the TS. These commands are send to the CoolMaster interface thanks the My Home
Gateway. This tutorial uses 3 of these interfaces, but at least we need one for each
internal unit that has to be controlled.
CoolMaster 1000D Daikin VRV takes the RS232 protocol and translate that into the
Daikin protocol, this interface is reliable to do this job is may be the easiest way to control
Daikin systems, also you can control many others brands using different CoolMaster part
number, in this case we are working with Daikin. This tutorial use the model 1000D which
works with Daiking but if you need to control other brand you just change the model 1000D
to the one you need, 2000S for Sanyo, 3000T for Toshiba, 4000M for Mitsubishi and so
on. All the steeps are the same even the IRSpliter configuration.
DS1206 this device takes the communication from the MH200N and translate that IP
protocol into RS232, also have in his core a piece of software that allows translating only
few specific strings from IP protocol (Home Web Net) into the RS232 that can be ear by
the CoolMaster. This device doesn’t have a AC-DC adapter so is necessary to buy one
12VDC positive center will do the job.
USB to RS232 Converter we are going to use this device only to put the CoolMaster in
simulation mode, and check the project. You need this only in case your PC don’t have
one of them, this device is used to simulate some internal units in the CoolMaster if you
have the actual units connected to the CoolMaster you probably won’t need this device.
www.myopen-legrandgroup.com
5
Open Web Net My Home – Daikin Interface
Building the set up
www.myopen
www.myopen-legrandgroup.com
6
Open Web Net My Home – Daikin Interface
Configuration
After building the Setup is time to configure all the devices. In this case configure the
devices with no particular order.
In the next sub sections there will be a reviewing of the configuration of each device.
MH200N
In this case we need the software TiMH200N, once is open do the next configuration:
Go to Ethernet, under Network Connection. We need to give a fixed IP to ensure the
connection with the TS1206.
IP Address: 192.168.1.40
Subnet Mask: 255.255.255.0
IP Router, Primary DNS, Secondary DNS: 192.168.1.1
www.myopen-legrandgroup.com
7
Open Web Net My Home – Daikin Interface
At this point we need to know the IP Address that the Ethernet Switch is giving to our PC.
First we need to open the shell command in our computer, and after that ask the computer
the ip address using the ipconfig instruction.
In this case we can see that the IP Address is 192.168.1.110
Remember that this address can change if you recycle the power of the switch.
www.myopen-legrandgroup.com
8
Open Web Net My Home – Daikin Interface
After that go to, IP Address enabling,
enabling, under Security and configured as show.
show In this step
we are going to open an IP Address for third
t
party software in this case the software of the
DS1206 Tibbo device.
IP address range 1: 192-192.168
192.168-168.1-1.248-250
IP address range 2: 192-192.168
192.168-168.1-1.108-111
Now the TS1206
S1206 must be inside this range, we are going to use 192.168.1.249 for the
TS1206.
In the case of the IP Address range 2, we are using 108-111
108 111 because our Switch is in the
192.168.1.110 address.
Now we can use the OpenClient to check all the traffic in the network.
www.myopen
www.myopen-legrandgroup.com
9
Open Web Net My Home – Daikin Interface
Ones you finish the set up we need to send that information to the MH200N, to do that you
need to connect the device using the network cable and transfer the info, just click the
Download icon under the Tools Menu, to be sure the next screen is going to ask the
current time and date, this mean you are transferring the info from the PC to the device.
And not the other way around.
www.myopen-legrandgroup.com
10
Open Web Net My Home – Daikin Interface
346020
The power supply 346020 no need any kind of configuration, only connect the power
outlet, the DC Power supply and the SCS BUS to the MH200N.
C9451
This is a Ethernet Switch in this case provided by BTicino no need any configuration.
L4684
This Touch Screen is going to be the human interface and need to have the three IRSplit
devices loaded in the configuration. Let’s review the configuration of this device.
Open the software TiTouchScreen V2.0 then click on New Project then click next
(Navigate Next).
www.myopen-legrandgroup.com
11
Open Web Net My Home – Daikin Interface
In the next screen add the temperature icon and click on next (Inner
(In er Next)
sc
Click Inner next until you see this screen
www.myopen
www.myopen-legrandgroup.com
12
Open Web Net My Home – Daikin Interface
Drag and drop the Air Conditioning icon to the screen and delete the External probes, then
click inner next.
Inside the Air conditioning screen, add three AC UNIT as show in the screen.
www.myopen-legrandgroup.com
13
Open Web Net My Home – Daikin Interface
Configure Unit 1 and Unit 2 as show below, only change the names Unidad 2 & Unidad 6
the rest of the parameters are the same. Unidad 2 will have the address ZA 0, ZB 2 & N 1.
Unidad 6 wil have the address ZA 0, ZB 6 & N 1.
www.myopen-legrandgroup.com
14
Open Web Net My Home – Daikin Interface
Configure Unit 3 as show below, the names is General and is going to command all the
units, General will have the address ZA 9, ZB 9 & N 1.
www.myopen-legrandgroup.com
15
Open Web Net My Home – Daikin Interface
After configuring all this only need to transfer to the touch screen, go to the last page by
clicking in the navigate next and send the configuration by clicking in the send
configuration under the tool menú.
www.myopen-legrandgroup.com
16
Open Web Net My Home – Daikin Interface
3456
This device take the commands from the Touch Screen to and send it to the Split unit in a
form of an IR stream, we are not going to control a Split unit but we need this device to
simulate that we have the Split unit, this way we get the proper SCS command in the bus
and the proper Open Web Net on the MH200N.
We need to open the IRSplit 1.0 using the command prompt this way we can open it as
administrator. Go to the folder C:\Programs Files\BTicino\IRSplit_0100 and run the
command IRSplit.exe /NOCHECK
In the folders choose Public, then Brands, Daikin and press the DB.
www.myopen-legrandgroup.com
17
Open Web Net My Home – Daikin Interface
Change the configuration as show below.
Then, press on NEW PROJECT and choose Advanced Project
www.myopen-legrandgroup.com
18
Open Web Net My Home – Daikin Interface
Fill the Description field and save the project with any name.
Now is time to send this new configuration to the 3456, connect the device and then click
on the icon “Find Port”, finally click on “Project Download”.
www.myopen-legrandgroup.com
19
Open Web Net My Home – Daikin Interface
After you finish upload the information to the three devices you most put the proper
configuration. As we show in the previous section, you can use physical or virtual
configuration.
Note:
In this example we use 3 devices 3456 one for each unit and also one extra for the
General Configuration. The 3 devices 3456 need the same software configuration. Also
you need to configure the 3456 with the same address we use in the touch Screen
configuration,
ation, this is important because the Touch Screen is going to speak with an 3456
specific. So the configuration is really important.
Is important to note that to check if this is working you put back this device in the set up
and move the temperature in the
the TouchScreen, if the 3456 is working you will see the a
LED blinking in the 3456.
www.myopen
www.myopen-legrandgroup.com
20
Open Web Net My Home – Daikin Interface
CoolMaster 1000D Daikin VRV
In this case in the CoolMaster we are going to simulate 2 units that way we can test our
system, This tutorial use some commands to do the simulation, but if you need further
information use the manual.
You can download the manual from the page http://www.coolautomation.com/ the manual
useful for this matter is CoolMaster Programmers Reference Manual (PRM) and use it to
simulate the 2 units and learn more about the features of this device.
Using any communication program as HyperTerminal or Putty connect to the CoolMaster
using a USB-RS232 cable, with the next settings:
Baud Rate: 9600
Data Bits: 8
Parity Control: None
Stop Bits: 1
Flow Control: None
www.myopen-legrandgroup.com
21
Open Web Net My Home – Daikin Interface
After you have communication, you can send this command to simulate the 10 units:
simul 10
The CoolMaster will respond with OK
We want to simulate 10 units because we have configured the units 6 and 2, as you can
remember from the configuration of the TouchScreen and the 3456
www.myopen-legrandgroup.com
22
Open Web Net My Home – Daikin Interface
Now we can check the status of the system with the “stat” instruction. After do the
checking let’s turn
urn off all the units, that way we can check later if the TouchScreen is
turning
urning the unit 2 and 6 back on, to do that send the instruction “alloff” the CoolMaster is
going to take a moment to accomplish the task.
www.myopen
www.myopen-legrandgroup.com
23
Open Web Net My Home – Daikin Interface
Check the status again. All the units are OFF
To finish the simulation you can type simul 0, or recycle power to the device.
Now the CoolMaster is in simulation mode, in this point you need to unplug the CoolMaster
from the USB-RS232 cable but not unplug from the power supply, and put back the device
in the original set up of our system.
www.myopen
www.myopen-legrandgroup.com
24
Open Web Net My Home – Daikin Interface
DS1206
Once we are at this point we only need to do one more configuration. In this steep we are
going to program the Tibbo DS1206, basically this device is going to sniff the IP network
looking for the Open Web Net command, generated by the 3456 device and when the
Tibbo see this command is going to translate this into the CoolMaster input command.
The driver inside the Tibbo is already develop you only need to load this piece of software
into the device, for doing this we need to download the software Tibbo IDE from the web
site http://tibbo.com/basic/product/tide.html and install it.
Once is installed you need to go to the software call Device Explorer.
www.myopen-legrandgroup.com
25
Open Web Net My Home – Daikin Interface
Click on the device, you can use the Buzz button to be sure is the device you want to
program, then click in Upload and Load Application through the Network. Here also put the
IP Address to the Tibbo, in the tutorial 192.168.1.249 is used.
After that, load the firmware MyHome, you can found this firmware in the Open Community
web page or attached to this PDF in the same ZIP folder, once you finish also you can put
the TS1206 back in the original setup.
www.myopen-legrandgroup.com
26
Open Web Net My Home – Daikin Interface
Now you need to go to the IP Address of the Tibbo, in this case 192.168.1.249.
192.168.1.249 You don’t
need any password to gett inside the configuration page leave that field empty and click on
Login
Just in
n the case that your Tibbo has the red led blinking in a heartbeat pace, you need to
initialize the device. But iff the Tibbo has the green led blinking you can go to the next step.
www.myopen
www.myopen-legrandgroup.com
27
Open Web Net My Home – Daikin Interface
After you initialize the device you need to change some setting to make the Tibbo work
fine.
In general settings you will have:
Login password: <empty>
Owner name: <empty>
Device name: <empty>
DHCP: Disable
IP-Address: 192.168.1.249 (IP Address of the TS1206)
Gateway IP-Address: 192.168.1.254 (IP Address of the switch)
Subnet Mask: 255.255.255.0
Serial Port Configuration-B: Option 0
Power on Pin9: Off
After change the configuration click on save button.
www.myopen-legrandgroup.com
28
Open Web Net My Home – Daikin Interface
In Gateway Settings you need to have:
Status: Disable
Connection Timeout: 5
Gateway IP-address: 192.168.1.248
Gateway Port: 20000
Serial Interface: Half-Duplex
RTS/CTS Flow Control: Disabled OR remote
DTR Mode: Idle OR remote
Power-up DTR State: LOW
Baudrate: 9600bps
Parity: None
Data Bits (0-7 bits, 1-8 bits): 1
Max. Intercharacter Delay (x 10ms): 1
Protocol timeout (x 1 sec): 5
After change the configuration click on save button.
Initialize button will do a full reset of the Tibbo and reset all the settings, Reboot do a soft
reset of the Tibbo keeping the setting as they are.
www.myopen-legrandgroup.com
29
Open Web Net My Home – Daikin Interface
Test
Let’s do some tests, the first is to test all the project together if this fails we are going to do
some part to part test.
1.- Check the temperature in the unit 2, after that change this temperature in the touch
screen and check it again, sometimes take half minute to change.
change
As you can see the temperature
ture goes from 22 to 19, it’s good, if you get this result the
system is working fine. In the pictures you can see the CoolMaster 1000D with a Vantage
sticker this is because in Europe the CoolMaster is distributed by Vantage but is the same
device you can buy any were in the world.
If we get this results we are just fine, and is not difficult to make a real system work
because the CoolMaster we handle most of the job. But if we don’t get this lets do some
basic troubleshooting.
www.myopen
www.myopen-legrandgroup.com
30
Open Web Net My Home – Daikin Interface
The first thing to check is the communication between the TouchScreen and
an the IrSplit, to
do this, change some parameter
eter in the TouchScreen like
l
the temperature and check if the
yellow LED is blinking, if not, check the TouchScreen and the IrSplit configuration.
Also you can check the OpenClient if there is any traffic when you change something in
the TouchScreen. If there is traffic that’s mean the Bticino part of the system is working
fine.
www.myopen
www.myopen-legrandgroup.com
31
Open Web Net My Home – Daikin Interface
Open the telnet client and using your USB-Serial
USB
interface connect
ct the RS232 to the
TS1206, in here when you change something in the TouchScreen you should see some
traffic information on the RS232 channel. In this case we are sending the instruction
General 21 degrees in the Touch Screen and we see this in the
t e output of
o the Tibbo.
Unit 6 at 23 degrees.. We see this. If you get to this point everything will be working fine.
www.myopen
www.myopen-legrandgroup.com
32
Open Web Net My Home – Daikin Interface
License
By using and/or copying this document, you (the licensee) agree that you have read, understood,
and will comply with the following terms and conditions:
Permission to copy, and distribute the contents of this document, in any medium for any purpose
and without fee or royalty is hereby granted, provided that you include the following on ALL copies
of the document, or portions thereof, that you use:
A link or URL to the www.myopen-legrandgroup.com.
The copyright notice of the original author, or if it doesn't exist, a notice (hypertext is preferred,
but a textual representation is permitted) of the form: "Copyright © [date-of-document]
www.myopen-legrandgroup.com. All Rights Reserved".
When space permits, inclusion of the full text of this NOTICE should be provided. We request that
authorship attribution be provided in any software, documents, or other items or products that you
create pursuant to the implementation of the contents of this document, or any portion thereof.
Any contributions to the document (i.e. translation, modifications, improvements, etc) has to be
submitted to and accepted by the My Open staff (using the forum of the community or sending an
email via the www.myopen-legrandgroup.com dedicated section) . Once the improvement has been
accepted the new release will be published in the My Open Community web site.
.
Disclaimers
THIS DOCUMENT IS PROVIDED "AS IS," AND COPYRIGHT HOLDERS MAKE NO
REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, NON-INFRINGEMENT, OR TITLE; THAT THE CONTENTS OF THE
DOCUMENT ARE SUITABLE FOR ANY PURPOSE; NOR THAT THE IMPLEMENTATION
OF SUCH CONTENTS WILL NOT INFRINGE ANY THIRD PARTY PATENTS,
COPYRIGHTS, TRADEMARKS OR OTHER RIGHTS.
COPYRIGHT HOLDERS WILL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL
OR CONSEQUENTIAL DAMAGES ARISING OUT OF ANY USE OF THE DOCUMENT OR
THE PERFORMANCE OR IMPLEMENTATION OF THE CONTENTS THEREOF.
The name and trademarks of copyright holders may NOT be used in advertising or publicity
pertaining to this document or its contents without specific, written prior permission. Title to
copyright in this document will at all times remain with copyright holders.
www.myopen-legrandgroup.com
33