ADC’s FPX series provides industry-leading fiber cable protection and management in a modular footprint. The panel utilizes an internal splicing system that creates a compact, feature-rich, high-density solution. FPX achieves densities of 24-fiber terminations/splices in 1 RU (1.75") and

144-terminations/splices in 5 RU (8.75") using SC connectors. These densities are attained while utilizing ADC’s angled adapters to ease cable access, protect bend radius and provide individual fiber access. Field-installable vertical cable guides on either side of the panel allow for managed routing and protection of the fiber entering and exiting the panel. The FPX’s wide range of features and options are designed for your networks’ growing needs.

Panels are equipped with adjustable mounting brackets to provide either 19- or 23-inch rack mounting with either four- or five-inch recess mounting. The panel is available preterminated with pigtails or adapters to simplify ordering and reduce installation time. Using LC small-form-factor connectors doubles the capacity of each panel.

Features:

• FPX panels combine the unique features of vertical cable guides and angle-left/angle-right adapters, offering bend radius protection, intuitive routing and easy connector access

• Rear access makes field termination or splicing fast and efficient. 1 RU and 2 RU versions feature convenient sliding access to terminations and splicing. 5 RU version features a hinged swing door on the back - provides technicians unrestricted access for splicing and reconfiguring cable

• Sold separately for maximum flexibility with minimum lead time, FPX adapter packs can also be pre-configured at the factory for more efficient service turn-up

• Provides an MPO cassette interface which eliminates the need for on-site fiber terminations or splicing, which decreases overall deployment time

• Panels are equipped with adjustable mounting brackets to provide either 19- or 23-inch rack or cabinet mounting (EIA or WECO) as well as 4- or 5-inch recess mounting

• FPX panels are available in a variety of sizes and configurations and utilize a single footprint w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1

FPX Series Fiber Panels

Next Generation FPL

Product Overview

Recommended Applications

Description

Number of fibers, future growth potential

Flexibility/ability to grow

Interconnect

Cross-connect

Accommodates on-frame splicing

Accommodates off-frame splicing

Rear access

All front access

Customer premises application

19" mounting

23" mounting

Mix equipment with fiber product?

Use as dedicated fiber frame

VAM capabilities

Optimum jumper storage location

Vertical Cable guide

Compliance

High-density termination/splice panel solution.

Often used in small wire closets or frames.

Ideal for small to medium fiber counts.

FPX Rack Mount Panel available in 1 RU, 2 RU or

5 RU chassis height configurations and include adapter only, termination/splice, or MPO cassette options.

12 to 288

Yes

Ideal

Yes

Yes. Built-in

Yes, with the purchase of separate IFC cable.

Multifiber clamp included.

Required

No

Ideal

Yes

Yes

Ideal

Not recommended (See ODF catalog #103743AE)

No

IMP or seperate storage panel required

Includes VCG on both sides

Meets UL 1863 and NEBS certification requirements w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 2

FPX Series Fiber Panels

Next Generation FPL

Density by Connector Type and Application

1

Size in Rack Units

2

Maximum Density

Termination Only Applications

LC connector:

SC connector:

Maximum Density

Termination/Splice Applications

LC connector

SC connector

Adapter Pack Configuration:

Features at a Glance:

48

24

96

48

5

288

144

48

24

96

48

288

144

2 modular adapter packs:

1 angle right/

1 angle left

4 modular adapter packs:

2 angle right/

2 angle left

12 modular adapter packs:

6 angle right/

6 angle left

Angled left/right adapters, highest density with maximum cable management features.

Specifications

Storage/operating temperature:

Approximate weight (empty panel)

Panel 1 RU = 9.5 lbs

Panel 2 RU = 12.75 lbs

Panel 5 RU = 19.75 lbs

40 to 85° C (-40 to 185° F)

Panel Configurations

FPX series chassis utilize modular adapter packs which are unique to either the right or left position of the chassis. The left / right position must be specified to ensure proper adapter orientation and color order in the backplane. Below illustrates the various configurations for the three available FPX chassis.

1 RU Chassis

APL / MPL APR / MPR

5 RU Chassis

APL / MPL APR / MPR

APL / MPL APR / MPR

2 RU Chassis

APL / MPL

APL / MPL

APR / MPR

APR / MPR

APL / MPL

APL / MPL

APL / MPL

APR / MPR

APR / MPR

APR / MPR

APL = angle left adapter pack

APR = angle right adapter pack

MPL = left MPO cassette

MPR = right MPO cassette

APL / MPL APR / MPR w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 3

4.0

5.0

FPX Series Fiber Panels

Next Generation FPL

Chassis Dimensions

1 RU Model

5"

17"

21.86" 1.72"

15.47"

2 RU Model

5"

15.47"

17"

21.86" 3.42"

5 RU Model

15.75” 16.4”

8.73” w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 4

FPX Series Fiber Panels

Next Generation FPL

MPO Cassette Optical Specifications and Polarity

FPX cassettes are wired straight through as per the recommendations made in TIA standard TIA-568-C

Connectivity Method A.

Key up mated connector to transceiver

A

Rx

Tx

B

A-to-B Patch Cord

A-to-A Patch Cord

Key up mated connector to transceiver

A

Rx

Tx

B

Key up to Key up mated connector

B

1

2

1

2

A

3

4

3

4

5

6

5

6

7

8

9

10

11

12

9

10

11

12

7

8

Key up to Key up mated connector

B

1

2

1

2

A

3

4

3

4

7

8

5

6

7

8

5

6

9

10

11

12

9

10

11

12

Type-A Array

Connector Cable

Cassette

Key up to Key down mated connector

Position 1 Position 1

A

Position 12 Position 12

Pinned

MPO Connector

Non-Pinned

MPO Connector

Cassette

Key up to Key down mated connector

Position 1 Position 1

A

Position 12 Position 12

Example Optical Path

Figure 1: Connectivity Method A for Duplex Signals

Low-loss MPO Connector

Singlemode

Insertion Loss at 1310/1550 nm Any Two Randomly Mixed Pairs

140

120

100

80

GR-1435

60

40

20

0

0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70

Insertion Loss (dB)

2500

2000

500

1000

500

Multimode

Insertion Loss at 850/1300 nm Any Two Randomly Mixed Pairs

GR-1435

TIA-568

0

0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75

Insertion Loss (dB) w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 5

FPX Series Fiber Panels

Next Generation FPL

24 Fiber LC - MPO Cassette Wiring

Key

Position 1 Position 12

MPO connector endface (reference)

MPO A

MPO B

MPO B

Key

Position 1 Position 12

MPO A

MPO connector endface (reference)

14

13

2

1

Top

12

11

24

23

Top row connects to

MPO adapter A

Bottom row connects to

MPO adapter B

12 Fiber SC - MPO Cassette

Cassette ports

Key

Position 1 Position 12

Top row connects to

MPO adapter A

Bottom row connects to

MPO adapter B

MPO A MPO A

MPO connector endface (reference)

13

14

1

2

Top

Key

Position 1 Position 12

MPO connector endface (reference)

11

12

23

24

Top Top

1

7

6

12

24 Fiber LC - MPO Cassette Wiring

Polarity/Wire Chart

Cassette Port No.

MPO-A MPO-B

Port 1 Port 13

MPO

Fiber Pos.

1

Port 2

Port 3

Port 14

Port 15

2

3

Fiber

Color

Blue

Orange

Green

Port 4

Port 5

Port 6

Port 7

Port 16

Port 17

Port 18

Port 19

4

5

6

7

Brown

Slate

White

Red

Port 8

Port 9

Port 10

Port 11

Port 12

Port 20

Port 21

Port 22

Port 23

Port 24

8

9

10

11

12

Black

Yellow

Violet

Rose

Aqua

Cassette ports

1

7

6

12

12 Fiber SC - MPO Cassette Wiring

Polarity/Wire Chart

Cassette Port No.

MPO-A

Port 1

MPO

Fiber Pos.

1

Fiber

Color

Blue

Port 2

Port 3

2

3

Orange

Green

Port 4

Port 5

Port 6

Port 7

4

5

6

7

Brown

Slate

White

Red

Port 8

Port 9

Port 10

Port 11

Port 12

10

11

8

9

12

Black

Yellow

Violet

Rose

Aqua w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 6

FPX Series Fiber Panels

FPX Series Rack Mount Fiber Panels: Standard Configurations

FPX Series Empty Chassis

The FPX series chassis can be purchased without adapter packs. In this form, the end-user can mix and match any combinations of modular FPX adapter packs or simply utilize a “grow as you go” approach to their network.

O r d e r i n g I n f o r m a t i o n

Description

Termination only rack or cabinet mount panel, putty white

1 RU empty panel, putty white; accommodates

1 angle LEFT and 1 angle RIGHT adapter packs;

T-handle latch close

2 RU empty panel, putty white; accommodates

2 angle LEFT and 2 angle RIGHT adapter packs;

T-handle latch close

5 RU empty panel, putty white: accommodates

6 angle LEFT and 6 angle RIGHT adapter packs;

T-handle latch close

Accessories

Heat Shrink Fusion Splice Tray

Blank plates

Height

1.75"

3.50"

8.75"

Catalog Number

FPX-1TR000-000

FPX-2TR000-000

FPX-5TR000-000

FST-HS-48

FPX-00AP00

FPX Series Standard Adapter Packs

The FPX series offers a variety of standard modular adapter packs to accommodate most applications.

The modular design is user-friendly and offers maximum flexibility to the end-user. ADC’s standard adapter pack offerings are SC and LC in both multimode and singlemode options. The same adapter packs are used throughout the FPX platform and oriented in the same direction in each chassis to optimize craft friendliness.

The FPX modular adapter packs can only be used with the FPX series panels. Each adapter pack contains labels that make it able to be loaded correctly in only one side of the panel. These craft friendly labels help insure correct installation. The FPX adapter packs are not interchangeable with ADC Fiber panels

(FL2000, FMT, or FL1000).

See ordering information on next page.

w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 7

FPX Series Fiber Panels

FPX Series Rack Mount Fiber Panels: Standard Configurations

Adapter only packs

O r d e r i n g I n f o r m a t i o n

Description

Multimode adapter only packs

SC adapters, beige color

12 adapters or 12 fiber ports per adapter pack

Angle LEFT adapter only pack

Angle RIGHT adapter only pack

SC adapters, aqua color 1

12 adapters or 12 fiber ports per adapter pack

Angle LEFT adapter pack

Angle RIGHT adapter pack

LC adapters, beige color

12 adapters 2 or 24 fiber ports per adapter pack

Angle LEFT adapter pack

Angle RIGHT adapter pack

LC adapters, aqua color 1

12 adapters 2 or 24 fiber ports per adapter pack

Angle LEFT adapter pack

Angle RIGHT adapter pack

Singlemode adapter only packs

SC ultra polish (UPC) adapters, blue color

12 adapters or 12 fiber ports per adapter pack

Catalog Number

FPX-12APL09

FPX-12APR09

FPX-12APLA9

FPX-12APRA9

FPX-24APL06

FPX-24APR06

FPX-24APLA6

FPX-24APRA6

Angle LEFT adapter pack

Angle RIGHT adapter pack

LC ultra polish (UPC) adapters, blue color

12 adapters 2 or 24 fiber ports per adapter pack

Angle LEFT adapter pack

Angle RIGHT adapter pack

SC angle polish (APC) adapters, green color

12 adapters or 12 fiber ports per adapter pack

FPX-12APL07

FPX-12APR07

FPX-24APL08

FPX-24APR08

Angle LEFT adapter pack

Angle RIGHT adapter pack

LC angle polish (APC) adapters, green color

12 adapters 2 or 24 fiber ports per adapter pack

FPX-12APL0J

FPX-12APR0J

Angle LEFT adapter pack

Angle RIGHT adapter pack

FPX-24APL0Z

FPX-24APR0Z

1 ADC recommends the use of aqua colored adapters with laser-optimized multimode fiber for 10 Gigabit (OM3) applications for circuit identification.

2 Each LC adapter accepts 2 fibers each w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 8

FPX Series Fiber Panels

FPX Series Rack Mount Fiber Panels

Adapter packs with pigtails

ADC’s FPX modular adapter packs are available to be shipped from the factory with preterminated 3 meter pigtails. These configurations can simplify the ordering process and reduce installation time and costs for the end-user.

Catalog Number

FPX - __ __ A P __ __ __ __ __ 3

Number of Fiber Ports per Bulkhead

12 12 Fibers

24 24 Fibers 1

Pack Orientation

L Left adapter pack

R Right adapter pack

Adapter Style

Multimode

06 LCMM

09 SCMM

A6 LCMM aqua 2

A9 SCMM aqua 2

Singlemode

08 LC/UPC

07 SC/UPC

0J SC/APC

0Z LC/APC

1

2

Pigtail Type

P

R

LC only

Stranded pigtails

Ribbon pigtails

Fiber Type

B 62.5/125 Multimode (OM1)

C 50/125 Multimode (OM2)

D 50/125 Laser optimized multimode to 300 meters (OM3)

S Singlemode

ADC recommends the use of aqua adapters to identify 10 Gigabit (OM3) circuits.

w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 9

FPX Series Fiber Panels

FPX Series Rack Mount Fiber Panels

FPX Pre-configured Termination/

Splice Fiber Panels

ADC’s FPX series fiber panels are available to be shipped with factory installed adapter packs and/or preterminated pigtail assemblies which simplifies the ordering process and reduces installation time and cost.

Catalog Number

FPX - __ __ R __ __ __ - __ __

Chassis Size (Color: Putty White)

Max Capacity

Description

1T 1 RU chassis

SC

24

LC

48

2T 2 RU chassis 48

5T 5 RU chassis 144

96

288

Panel Height

1.75"

3.5"

8.75"

Adapters/Pigtails

A Adapter only

P

Stranded pigtails

Singlemode

R

Multimode (62.5/125) OM1

Ribbon pigtails

Singlemode

Stranded pigtails

B

G

Multimode (50/125) OM2

Stranded pigtails

Multimode (50/125) OM3

Laser optimized to 300M

Adapter/Connector Style

Multimode

06 LCMM

09 SCMM

A6 LCMM aqua 1

A9 SCMM aqua 1

Singlemode

08 LC/UPC

07 SC/UPC

0J SC/APC

0Z LC/APC

Splice Type

1 Bare Fusion

2

3

Heat Shrink Fusion

Mechanical

Ports Loaded

12 12

24

48

24

48

72

96

72

96

144 144

288 288 2

1 ADC recommends the use of aqua adapters to identify

10 Gigabit (OM3) circuits.

2 LC only w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 10

FPX Series Fiber Panels

FPX Series Rack Mount Fiber Panels

FPX MPO Cassettes

ADC’s FPX series MPO cassettes utilize the same user interface as the modular adapter packs, but offer the end-user the flexibility of a plugand-play MPO architecture. Each cassette has a front bulkhead identical to the adapter pack with an internal cable assembly converting to an

MPO male connector. This assembly is housed in an enclosed cassette with a rear MPO adapter allowing the user to utilize an MPO trunk to turn up service.

O r d e r i n g I n f o r m a t i o n

Description

Multimode cassettes

12 fiber cassettes;

12 SC (aqua) multimode adapters; 50/125 fiber laser optimized to 300 meters (OM3)

Angle LEFT cassette

Angle RIGHT cassette

24 fiber cassettes;

12 LC (aqua) multimode adapters 1 ; 50/125 fiber laser optimized to 300 meters (OM3)

Angle LEFT cassette

Angle RIGHT cassette

Singlemode cassettes

12 fiber cassettes; 12 SC/UPC singlemode adapters; singlemode fiber

Angle LEFT cassette

Angle RIGHT cassette

24 fiber cassettes; 12 LC/UPC singlemode adapters 1 ; singlemode fiber

Angle LEFT cassette

Angle RIGHT cassette

12 fiber cassettes; 12 SC/APC singlemode adapters; singlemode fiber

Angle LEFT cassette

Angle RIGHT cassette

1 Each LC adapter accepts 2 fibers each

Catalog Number

FPX-12MPLDA9

FPX-12MPRDA9

FPX-24MPLDA6

FPX-24MPRDA6

FPX-12MPLS07

FPX-12MPRS07

FPX-24MPLS08

FPX-24MPRS08

FPX-12MPLS0J

FPX-12MPRS0J w w w . t e . c o m / a d c • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 11

Tyco Electronics Corporation

8000 Purfoy Road

Fuquay Varina, NC 27526-9349

Tel: 919-557-8900

Fax: 919-557-8498 www.tycoelectronics.com

www.us.telecomosp.com

Tyco Electronics Corporation. All rights reserved.

109156AE 1/11 Revision © 2011, 2010

ADC, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors.

While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this document, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult

Tyco Electronics for the latest dimensions and design specifications.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement