Marco Ecoboiler UC4L Service manual

Add to My manuals
24 Pages

advertisement

Marco Ecoboiler UC4L Service manual | Manualzz

UNDERCOUNTER

SERVICE MANUAL

Ecoboiler UC4L 2.4kW

1000740

Ecoboiler UC10L 2.8kW

1000741

Ecoboiler UC10L 5.6kW

1000742

Ecosmart UC4L 2.4kW

1000750

Ecosmart UC10L 2.8kW

1000751

Ecosmart UC10L 5.6kW

1000752

Marco Beverage Systems Ltd.

63d Heather Road,

Sandyford Industrial Estate,

Dublin 18,

Republic of Ireland

Ireland Tel:

(01) 295 2674

Ireland Fax:

(01) 295 3715

UK Tel:

(0207) 274 4577

UK Fax:

(0207) 978 8141

1. INTRODUCTION:

The information provided in this manual is intended to assist in the installation and maintenance of the Marco Ecoboiler Water boiler. Please read the instructions carefully to prevent accidents and ensure an efficient installation.

This manual is not a substitute for any safety instructions or technical data affixed to the machine or its packaging. All information in this manual is current at the time of publication and is subject to change without notice.

Only technicians or service providers authorised by Marco should carry out installation and maintenance of these machines.

Marco accepts no responsibility for any damage or injury caused by incorrect or unreasonable installation and operation.

2. SAFETY INSTRUCTIONS:

Read all instructions.

To protect against electric shock do not immerse mains cord in water or other liquid.

To prevent chafing of the cable, do not let the mains cord hang over the edge of a table or counter ; or touch hot surfaces.

Do not operate any appliance with a damaged cord, plugs, or after the appliance malfunctions or has been damaged in any manner.

Switch off at the mains (unplug or disconnect from outlet) and turn off the water supply when not in use and before cleaning. Allow to cool before removing components.

The use of spares and accessories not recommended by Marco may cause damage and/or injuries.

Do not use outdoors. Do not place on or near a hot gas or electric burner.

Do not use the appliance for anything other than its intended use.

Save these instructions.

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 2 of 24

3. BASIC INSTRUCTIONS:

3.1. INST ALL ATION DE T AILS:

Electrical installation:

Ecoboiler UC4L 2.4kW, Ecosmart UC4L 2.4kW - A moulded 13A plug is factory fitted.

Ecoboiler UC10L 2.8kW, Ecosmart UC10L 2.8kW - A moulded 13A plug is factory fitted.

Ecoboiler UC10L 5.6kW, Ecosmart UC10L 5.6kW - This unit must be connected to a suitable single phase power supply. This should be done by a qualified electrician.

Plumbing insta llation proce dure:

Note: Marco cannot be held responsible for any flood damages.

Mains water pressure required (limits): 5-50psi (35-345kPa)

Fit a stop Valve on a cold water line and attach a 3/4" BSP male fitting,

(e.g. 3/4" x 1/2" 311 or washing machine type stop valve).

Connect straight tailpiece of the inlet hose to the stop valve fitting. Make sure that the preattached sealing washer is fitted.

Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow several gallons through.

Connect right-angled tailpiece of the hose to the inlet valve of the boiler (again 3/4" BSP).

Make sure the sealing washer is fitted here also.

Turn on water and check for leaks.

3.2. OPER ATION:

Check that all installation procedures have been carried out.

Ensure water valve is on.

Plug boiler into 13A socket and press power button on the front of the machine marked

‘Power’.

Ecoboiler UC4L/ Ecoboiler UC10L

 The “power on” light will glow green and the machine will fill to a safe level, above the elements, before heating.

 The “Ready/Status” light will cycle two red flashes while the machine is filling to the safe level.

After this amount of water has heated to about 96ºC the boiler will draw more water in until the temperature drops by 1 or 2 degrees. The boiler will then heat again. This heat fill cycle continues until the boiler is full.

On a 10L machine, whilst the machine i s above the safe level and filling, the “Ready/Status” light will remain blank.

 The “Ready/Status” light will glow green when the machine is both full and up to normal operating temperature.

The boiler is now ready for use.

Ecosmart UC4L /Ecosmart UC10L

T he “power on” light will glow green and the machine will fill to a safe level, above the elements, before heating. The display will show the current water temperature and the status “

Filling…”

 The “Ready/Status” light will cycle two red flashes while the machine is filling to the safe level.

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 3 of 24

After this amount of water has heated to about 96ºC the boiler will draw more water in until the temperature drops by 1 or 2 degrees. The boiler will then heat again. This heat fill cycle continues until the boiler is full.

 While filling, the “Ready/Status” light will remain blank.

 The “Ready/Status” light will glow green when the machine is both full and up to normal operating temperature. For 10L machines allow approx 30 minutes.

The boiler is now ready for use

– the display will show the Water Temperature and the status “

READY”.

The Boiler may now be used to dispense Hot Water to the preset factory settings. o 94’C o Push and Hold operation o Continuous flow – no pulsing o Auto heat Fill Mode.

Power

Button

Ready/Status

Indicator

Ecomode

Button

Ecoboiler UC4L/ Ecoboiler UC10L Ecosmart UC4L /Ecosmart UC10L

NOTE:

Because the boiler is electronically controlled no priming is necessary.

The element cannot switch on until a safe level of water is reached.

3.3. TEMPER ATURE CALIBR ATION

Ecoboiler UC4L/ Ecoboiler UC10L

The Ecoboiler control PCB (1600345) has the ability to have the desired set-point temperature at whatever setting is required. During manufacture of the PCB it is set to the default temperature of around 95°C.

If the temperature setting needs to be modified on-site please follow the steps below:

1. To Enter Calibration mode: a. Turn the machine off at the mains power supply. b. Then, whilst depressing the tactile switch on the PCB, turn the mains power back on. c.

All available LED’s on the front panel will now blink continuously. d. The machine is now in Calibration mode.

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 4 of 24

2. In Calibration Mode the machine will heat continuously until the tactile switch on the PCB is pressed for a second time (NB: The tactile switch should be pressed for at least 1 second)

3. Using a thermometer to measure the temperature at the thermistor pocket, the machine should be allowed to reach the desired set-temperature. (NB: It may be necessary to let the unit cool down if the desired set point is lower than the units current temperature)

4. Following a correct calibration procedure the tank temperature should be maintained within

3°C of the desired set-point temperature.

In the event of an incorrect calibration process the steps below should be followed:

5. If the tactile switch is pressed too early and the temperature is set lower than desired, the tester should simply repeat calibration.

6. If the tactile switch is pressed too late and the set temperature is too high, the tester will need to wait for the temperature in the tank to cool, or add cool water, and then repeat calibration.

Ecosmart UC4L /Ecosmart UC10L

PLEASE REFER TO INSTRUCTION BOOKLET FOR TEMPERATURE CALIBRATION.

3.4. TIME/VOLUME DISPENSE C ALIBR AT ION

Ecoboiler UC4L/ Ecoboiler UC10L

1. Open the service panel.

2. Make sure that the machine is powered, filled and heated (ready lamp green).

3. Press calibration tactile button on the PCB for a second until status lamp starts blinking red-green.

4. Set new dispense time by pressing dispense button to obtain the required output volume of water.

Button may be pressed several times – all times / volumes will be added together.

5. To confirm and save new value press calibration button on the PCB for a second until the status lamp stops blinking.

6. S etting dispense time / volume to zero (omit step 4) will make the machine work as “push & hold”

(water dispensed as long as the button is pressed).

3.5. TROUBLESHOOTING

The Ready/Status light signals various errors or problems.

A cycle of red flashes indicates an error. The number of flashes in a cycle corresponds to the symptom in the table below:

Status/Diagnostic light guide:

No of flashes

Symptom Action required

2

Water level below elements. Normal when machine first fills.

Check water pressure , if this is OK then call service agent.

3

4

5

Temperature sensor failure (s/c)

Water not heating

Temperature sensor failure (o/c)

Call service agent

Call service agent

Call service agent

6 Machine not filling Check water pressure.

Note: Some of the erro r se quen ces will be displa yed if there is lo w wate r p ressu re.

Please check that there is wate r p ressure and that the wa ter stop -va lve is op en before callin g you r service a gent.

For a more detaile d description of error ind icato rs and corre ctive actions see s ection

4.7 of this manual.

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 5 of 24

3.6. M AINTEN ANCE:

Marco machines have been designed to give many years of trouble free service. Marco Beverage

Systems manufacture and test to ISO9002:2000 standard. The only regular maintenance required is occasional de-scaling.

Descaling Procedure:

Isolate machine from power supply.

Isolate machine from water supply.

ALLOW TO COOL COMPLETELY!

Drain water from machine.

Remove all lids.

Remove as much scale as possible by hand, paying particular attention to level probes (White plastic with steel tab). Be very careful not to damage any attachments.

Use ScaleKleen, Marco part No. 8000270 or similar. Follow instructions carefully.

Thoroughly clean and flush the machine before re-use.

Follow installation and first time operation instructions

3.7. CLE ANING:

The exterior of these machines may be cleaned with a damp cloth and a light detergent. Do not use abrasive cloths or creams, as this will spoil the finish of the machine. Do not use a water jet or spray.

Beware of accidentally operating the draw off tap or push button when cleaning the front of the machine.

3.8. LIMESC ALE:

In common with all water boiler manufacturers, service calls resulting from limescale are not covered by warranty. Fitting a scale reducer is recommended, especially in hard water areas. This can reduce the build-up of scale but may not stop it altogether. The frequency that descaling is required depends on the local water supply; hard water areas need more attention. A scale reducer can reduce the build up of scaling, but may not stop it altogether. Descaling of the machine should ideally be carried out by qualified service personnel.

3.9. C AUTIONS AND SAFETY TIPS:

This appliance must be earthed. If the moulded plug supplied is not used then ensure that the green/yellow cable is connected to a suitable earth.

Risk of flooding. The hose supplied with this unit is non-toxic food quality tested to 190psi.

However, a hose is not a permanent connection. It is, therefore, advisable to switch off boiler and close the stopcock valve when boiler is not in use, e.g. overnight, weekends etc.

Risk of scalding. Beware of accidentally operating the water drawoff tap especially when cleaning the front of the boiler.

The utmost care has been taken in the manufacture and testing of this unit. Failure to install, maintain and / or operate this boiler according to the manufacturer’s instructions may result in conditions that can cause injury or damage to property. If in any doubt about the serviceability of the boiler always contact the manufacturer or your own supplier for advice.

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 6 of 24

4. Technical Data:

4.1. GENER AL DESCRIPTION:

Height (mm)

Width (mm)

Depth (mm)

Ecoboiler

UC4L

2.4kW

394

135

585

Ecoboiler

UC10L

2.8kW

394

226

585

Ecoboiler

UC10L

5.6kW

394

226

585

Ecosmart

UC4L

2.4kW

394

135

585

Ecosmart

UC10L

2.8kW

394

226

585

Ecosmart

UC10L

5.6kW

394

226

585

I mmediate

Draw-Off

(litres)

Max. Hourly

Output (L/hr)

4L

24L

10L

28L

10L

56L

Connection 2.4kW,

230V, c/w

1.5m flex and moulded

Fittings

Pressure

2.8kW

230V, c/w

1.5m flex and moulded

5.6kW. must be connecte d to single plug - fused

(BS1363). plug - fused

(BS1363)

. supply

0.75” BSP

Food grade inlet hose supplied

5-50 psi (35-345 kPa) phase power

4L

24L

10L

28

10L

56L

2.4kW,

230V, c/w

1.5m flex and moulded plug - fused

(BS1363)

.

2.8kW

230V, c/w

1.5m flex and moulded plug - fused

(BS1363).

5.6kW. must be connected to single phase power supply

4.2. EXTERN AL ARR ANGEMENT boiler UC4L/ E

Hose adapter to font

Wiring Connector to font

Vent

Hose adapter to font

Wiring Connector to font

Controls

Controls

Service Panel

Service Panel

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 7 of 24

4.3. ACCESS TO INTERN AL COM PONENTS:

To access the tank:

Allow to cool. Remove the outer lid. To remove outer lid, undo 4 pozi headed screws.

Ensure that the tank is cool, before removing insulation and inner lid. To remove inner lid, undo 4 butterfly nuts.

Ecoboiler UC10L / Ecosmart UC10L(SHOWN)

Ecoboiler UC4L / Ecosmart UC4L(SHOWN)

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 8 of 24

To access the internal components:

Disconnect the machine from the electrical supply.

Allow to cool sufficiently.

On the 10L machine insert a flat headed screwdriver at the four locations indicated on the picture above and rotate. Note:- There is no need to ‘lever’ the screwdriver – a small rotation is all that is required.

In the case of the 4L machine remove the 4 screws on the service panel located on the right hand side.

Place the panel to the side of the machine. This allows access to most of the internal

components and the machine does not need to be drained for most maintenance or service operations.

The Tank can be drained by removing the plug from the end of the drain hose, and draining into an external drain or a large enough container.

Ecoboiler UC10L / Ecosmart UC10L (SHOWN)

Ecoboiler UC4L / Ecosmart UC4L (SHOWN)

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 9 of 24

4.4. INTERN AL ARR AN GEMENT:

Thermal Switch

90deg, M4 Stud

Mount (1502088) and

Thermal Switch

Mount Brass

(1502089)

PCB Display

Ecoboiler 10L

(1600349)

Or

PCB Ecosmart

Display

(1600357)

PCB Bracket

PCB Ecoboiler

Control (1600345) or

P.C.B Eco Slave

(1600354)

Pump Muller 24V DC

(1501542)

Font connection assembly ( see: UCEC-001A)

Connector Mini Fit 4 Way Socket 1400611

High Level Probe Assembly (2300463)

Low Level Probe Assembly (2300463)

Thermal Switch

130Deg (1502087)

Element 2.4kW 230V

Ring Shape

(1500950)

P.C.B 24V DC Pump

Supply

(1600366)

Valve inlet

Solenoid 2L

(1502191)

Drain Hose

Ecoboiler UC4L/ Ecosmart UC4L

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 10 of 24

Font connection assembly

( see: UCEC-001A)

Connector Mini Fit 4 Way Socket 1400611

High Level Probe Assembly

(2300463)

P.C.B 24V DC Pump Supply

(1600366)

Thermal Switch

90deg, M4 Stud

Mount (1502088) and

Thermal Switch

Mount Brass

(1502089)

PCB Ecoboiler

Control (1600345) or

P.C.B Eco Slave

(1600354)

Mid Level Probe Assembly

(2300463)

NOT SHOWN

Low Level Probe Assembly

(2300463)

Pump Muller 24V DC

(1501542)

Element 2.8kW 230V

(Butterfly)

(1500985)

Contactor B&J 240V AC

(1500840)

Ecoboiler UC10L/Ecosmart UC10L

4.5. PCBs:

4.5.1. PCB La yout:

Ecoboiler UC4L/Ecoboiler UC10L

PCB Ecoboiler Control (1600345):

Controls the heater switching

Controls the water inlet switching

Controls tank temperature/temperature adjustment

PCB Ecoboiler Display 10L (1600349) consists of:

 Power On/Off button

Power On LED

 Status/Ready LED

ECO Mode On/Off Button

 ECO Mode On LED

Ecosmart UC4L/Ecosmart UC10L

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11

Thermal Switch

130Deg (1502087)

Valve inlet

Solenoid 2L

(1502191)

Drain Hose

Page 11 of 24

PCB Eco Slave (1600354):

Controls the heater switching

Controls the water inlet switching

Controls tank temperature/temperature adjustment

PCB Ecosmart display (1600367) consists of:

LCD screen

Power On/Off button

 Power On LED

Status/Ready LED

 ECO Mode On/Off Button

 ECO Mode On LED

4.5.2. PCB Ec oboiler Control:

PCB Ecoboiler Control (1600345) / PCB Eco Slave (1600354):

8

9

7

10

11

6 6

12

5

13

4

3

14

15

19

16

2

1

19

17

18

1. Dispense Solenoid Tab

2. Inlet Solenoid Tab

3. Neutral Tabs

4. Transformer

5. Mains Live In Tab

6. Relays - Heater. Switch the element

7. Heater Tab

8. On/Off 2-way Connector. Short circuited on this Ecoboiler machines – power switch controlled through the display PCB

9. LED 5-way Connector

10. Earth Tab

11. Daughter PCB Connector (low voltage). Connects to Daughter PCBs

– allows switching of more than one element

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 12 of 24

12. External Connector

13. Thermistor Connector

14. Dip Switch

– 3 way. Allows selection of software for specific machine

15. Tactile Switch. For use during calibration procedure (refer to Calibration in Sec 3.3)

16. Water Level – 5-way connector (low voltage). Connects to Low level and High level probes. Also connects push button on PB variants.

17. Button Connector

– 4-way

18. Data I/O Connector – 4-way

19. Relays – Inlet Solenoid

4.5.3. PCB ECOSM ART Displa y (1600357 )

1. Power On LED’s. Shows that machine is switched on

2. Power On/Off switch

3. Status LED’s. Displays Error signals via a flashing RED LED

4. Eco Mode On LED’s

5. Eco Mode On/Of Switch

6. 2 way connector – to Font connector

7. 16 way connector – to PCB Ecoboiler 1600354

1

2

3 7

6

4 5

( For assembly order of 1600357 see :ECOS-020A PCB ECOSMART DISPLAY ASSEMBLY)

4.5.4. PCB Displa y Ecoboiler 10L (1600349 )

1. Power On LED’s.Shows that machine is switched on

2. Power On/Off switch

3.

Status LED’s. Displays Error signals via a flashing RED LED

4. Eco Mode On LED’s

5. Eco Mode On/Of Switch

6. 5 way connector

– to PCB Ecoboiler LED connector

7. 4 way connector

– to PCB Ecoboiler BUTTONS connector

2

3

5

7 6

1

4

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 13 of 24

4.6. TROUBLESHOOTING – DIAGNOSTIC GUIDE:

NOTE FOR THE ECOSMART RANGE IN ADDITION TO THE STATUS LED FLASHING TO

INDICATE AN ERROR

– THE DISPLAY WILL ALSO PROVIDE INFORMATION

2 FLASH CYCLE – BELOW LOW LEVEL

Display pattern:

2 flashes then a short pause - repeated.

Electronic check and action:

This indicates that the low level circuit is open i.e. the probe is not in contact with the water.

The element is switched OFF at this stage and the inlet is left ON.

(note that if this is a low probe wiring fault, the water will stop at the high level probe regardless of the status of the low level).

This is a recoverable error i.e. the machine does not need to be reset when the problem is solved. (e.g. if a closed mains water stop valve is the problem, opening the valve will allow water into the machine and normal function will resume when the low level probe is reached)

Probable causes:

The water level is below the low level probe, which is normal when the machine fills for the first time. (Can be flashing for up to 2 min at start up)

The low level probe wire is disconnected, or there is another wiring fault

(eg. a bad earth (return) connection between the PCB and the Tank)

Check that the water pressure is OK and ensure that the stop valve is Action required: open.

Check that the inlet solenoid is working.

If the water level is above the level of the low probe, check the probe circuit wiring

3 FLASH CYCLE

– THERMISTOR OPEN CIRCUIT

Display pattern:

3 flashes then a short pause - repeated.

Electronic check and action:

This indicates that the Thermistor is measuring such a large resistance that it assumes the thermistor circuit is open.

The element and inlet valve are turned OFF when this error is detected

This is a recoverable error. When the correct range of resistance is measured, normal operation resumes

Probable causes:

The thermistor probe is unplugged from the 4way connector on the PCB or the thermistor has failed open circuit.

Action required:

Check that the thermistor is plugged in to the PCB correctly. If it is, replace the thermistor.

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 14 of 24

4 FLASH CYCLE – NOT HEATING

Display pattern:

4 flashes then a short pause - repeated.

Electronic check and action:

This checks that the temperature is increasing when the heater is on.

Measures the rate that the temperature increases in a specified time.

This error is only displayed after 20 mins of the heater being on continuously. When the error is detected, the element and inlet valve are turned off.

This is a non recoverable error. The machine needs to be reset when this problem is solved.

Probable causes:

The elements have failed

Wiring fault

Action required:

Check that the resistance on the elements. If there is a reasonable resistance (1525Ω)on the element it probably has not failed, so the wiring might be at fault.

5 FLASH CYCLE

– THERMISTOR SHORT CIRCUIT

Display pattern:

5 flashes then a short pause - repeated.

Electronic check and action:

This indicates that the Thermistor is measuring zero resistance. It assumes the thermistor has failed sort circuit.

The element and inlet valve are turned OFF when this error is detected

This is a recoverable error. When the correct range of resistance is measured, normal operation resumes.

Probable causes:

The thermistor has failed.

Action required:

Replace the thermistor.

6 FLASH CYCLE – NOT FILLING

Display pattern:

6 flashes then a short pause - repeated.

Electronic check and action:

This checks that the water in the tank cools when the inlet solenoid valve is switched on.

This is a non-recoverable error. This checks that the water in the tank is cooled by when the inlet solenoid valve is opened. If the water pressure is within the specifications (5-50psi), the inlet solenoid should not be on for more than a few seconds. If this water temperature has not decreased by the required amount

(1 degree per minute), the inlet solenoid is switched off and the 6 flash cycle is displayed.

Probable causes: 

Mains water pressure problem or the mains water stop valve is closed.

Inlet solenoid valve failure.

Action required:

Check the mains water supply. (Note: Temporary loss of water pressure can occur in certain sites

– particularly when various machines are plumbed to the same mains water supply.) If the water supply is ok, reset the machine (switch the machine Off and On again). This will reset

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 15 of 24

the error and if the water supply is ok, the machine will return to normal operation.

NOTE: If the water supply is the problem, ensure that this is rectified or this error will re-occur.

If there is no problem with the mains water supply, check that the inlet solenoid valve is working.

4.7. Tank Components

The tank internals are detailed below. Care should be taken when cleaning inside the tank.

The level probes provide much of the control inputs into the PCB and are critical to the operation of the machine. The wiring to these should be checked regularly and the probes themselves should be cleaned whenever the machine is serviced.

There are 3 level probes on the 10L Ecoboiler versions and 2 level probes on the 4L versions.

Ecoboiler UC10L/Ecosmart UC10L Ecoboiler UC4L/ Ecosmart UC4L

Tank Gasket

Probe Assembly (2300463) – High position

Probe Assembly (2300463) – Mid position

ON 10L ONLY

Probe Assembly (2300463) – low position

Thermistor Pocket – ensure that this is not touching the element.

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 16 of 24

4.8. Descaling Procedure

To descale the machine thouroughly:

Unplug the machine.

Disconnect from the water supply.

Drain as much water from the tank as possible.

Remove the lids and allow the machine to cool completely.

Drain all the water from the machine.

Attempt to remove as much scale as possible by hand.

Reconnect machine and start up once again.

Add a descale solution (follow instructions as given). Flush the machine thouroughly before use

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 17 of 24

4.9. Wiring diagram: Ecoboiler UC4L 2.4kW 1000740

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 18 of 24

4.10. Wiring Diagrams: Ecoboiler UC10L 1000741

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 19 of 24

4.11.

Wiring Diagram : Ecoboile r UC10L 5.6kW 1000742

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 20 of 24

4.12. Wiring Diagram: Ecosmart UC4L 1000750

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 21 of 24

4.12. Wiring Diagram: Ecosmart UC10L 1000751

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 22 of 24

4.12. Wiring Diagram: Ecosmart UC10L 5.6kW 1000752

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 23 of 24

4.13. Spare Parts List

Part

Number

Description

1500950 Element 2.4kW 230V

Ring Shape

1500985 Element 2.8kW 230V

1501430 Moulded Plug and cord

1501542 Pump Muller 24V DC

1502087 Thermal Switch 130Deg

1502088 Thermal Switch 90deg,

M4 Stud Mount

1502089 Thermal Switch Mount

Brass

1502191

Valve Inlet Solenoid 240V

- 2L/min

1600345 PCB Ecoboiler Control

1600349 PCB Ecoboiler Display

10L

1600354 P.C.B Eco Slave

1600357K P.C.B 357 Spares Kit

1600366 P.C.B 24V DC Pump

Supply

1600691 Thermistor Assembly

1800306 Gasket Inner Ecoboiler

1800314 Gasket inner UC4

1801810 Service Panel 1000741

1000742

1801811 Service Panel 1000751

1000752

1900673 Label UC Ecosmart 4-10L

1900674 Label UC Ecoboiler 4-10L

2300384 Lid Inner Ecoboiler

2300388 Lid 1000741 1000742

1000751 1000752

2300389 LID Inner 1000740

1000750

2300393 LID OUTER 1000740

1000750

2300394 Service Panel 1000740

1000750

2301463 Level Probe Assembly

8800121 Descale Box – 6 Packs

Ecoboiler

UC4L

2.4kW

1000740

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

Ecoboiler

UC10L

2.8kW

1000741

Model Variant

Ecoboiler

UC10L

5.6kW

1000742

Ecosmart

UC4L

2.4kW

1000750

X

Ecosmart

UC10L

2.8kW

1000751

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

MARCO is an

ISO9001:2000

Registered

Company.

X

X

X

X

X

X

Ecosmart

UC10L

5.6kW

1000752

X

X

X

X

X

X

X

X

X

X

Service manual 1000740 1000741 1000742 1000750 1000751 1000752 06-12-11 Page 24 of 24

advertisement

Related manuals

Download PDF

advertisement