American Dynamics ADTTE is a highly intuitive, easy-to-use keyboard controller designed to give you complete control over your CCTV surveillance system. With its user-friendly interface, you can quickly and easily access all of your cameras, presets, patterns, and more. Whether you're a security professional or a homeowner, ADTTE gives you the power to keep an eye on what matters most.
Advertisement
Advertisement
Using MegaPower
®
48 Matrix Switcher with
ADTTE Keyboard Controller
Operation and Programming Reference Guide
Figure 1: MegaPower 48 (MP48) Typical Configuration
Digital
Video Recorder
Programmable
Dome
Camera
MegaPower 48
Matrix Switcher/
Controller System
Recorder Control
Devices
Alarm
Input
Pager
Monitor
ADTTE
Touch Tracker
Keyboard
Figure 2: ADTTE Keyboard Controller
AD2088
Keyboard
PTZ xt
5 n
© 2004 Sensormatic Electronics Corp.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
1 of 43
8200-0170-05, REV. A
Contents
About this Guide.................................................... 2
About the MegaPower 48 Matrix
Switcher/Controller System................................... 3
About the ADTTE Keyboard Controller ................. 3
Identifying the ADTTE Operating Mode ................ 6
General User Tasks .............................................. 7
Working in Keyboard Lock Mode .......................... 7
Working in Program Mode................................... 14
Changing ADTTE Keyboard Settings.................. 20
Working in Menu Mode ....................................... 22
Changing System Settings.................................. 23
Changing Monitor Settings.................................. 27
Changing Camera Settings ................................. 28
Configuring User or Keyboard Settings............... 30
Configuring Switching Settings ........................... 33
System Partitioning ............................................. 37
Configuring Alarms.............................................. 39
Declarations ........................................................ 43
About this Guide
This operation and reference guide explains tasks you can perform using the ADTTE keyboard with the MegaPower 48 (MP48) Matrix Switcher. It supplements material found in the following documents:
• ADTTE Enhanced Touch Tracker Operator’s
Manual, 8000-2675-02
• MegaPower 48 (MP48) Matrix Switcher/
Controller Programming & Operation Manual,
8000-1804-51
If you need assistance...
Contact your Sales Representative.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
2 of 43
8200-0170-05, REV. A
About the MegaPower 48
Matrix Switcher/Controller
System
The MegaPower 48 (MP48) Matrix Switcher/
Controller System is an integrated matrix switching and control system for CCTV surveillance systems. It provides multiple video inputs, outputs, and control stations.
The MP48 system can also respond to alarms and perform auxiliary switching for the control of gates, doors, lights, and other output devices.
Depending on the control requirements of a given application, various AD keyboards and accessory devices can be used with the system.
The MP48 provides the following features:
• Matrix size of 48 video inputs by 16 video outputs
> Eight video outputs with text overlay
> Eight public view video outputs
• Modular wall mount with rack mount option
• Embedded menus for system setup programming
• Flash memory module on system for data backup
• Video recorder control using AD2088 keyboard
• Macro programming and control using
AD2088 keyboard
• Fixed and variable speed pan/tilt and dome control using SensorNet, RS-422, or AD
Manchester protocols
• Alarm responses include camera, presets, patterns, salvos, text paging, recorder and auxiliary control
• Text paging on alarm with up to 250 different messages
• System partitioning for inputs, outputs, and keyboards
• System priority levels and user password
• Monitor tours
• On-screen text includes displaying video input number, monitor status, time/date information, and titles for cameras/presets/alarms
• 64 universal tours
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
3 of 43
• 64 system salvos
• 35 event timers
• Alarm tables for system, dome, communications (RS-232), and video loss alarms
• Automatic call up of alarm inputs
• 4096 preset titles
• On-board system diagnostics
External communications to system devices can be achieved through a variety of protocols, including Manchester Control Code, RS-232,
RS-422, and SensorNet.
About the ADTTE Keyboard
Controller
The ADTTE keyboard is a video control station that is compatible with the MP48 matrix switcher/ controller systems. The keyboard provides the following operating modes: Keyboard Lock
(Operate), Program, and Menu modes. All operators may use the Keyboard Lock mode.
Operators with password privileges may use
Program and Menu modes.
Keyboard Lock mode does not require password privileges and provides the following functions:
• Monitor and camera selection
• Camera and dome control
• Preset, pattern, salvo and system tour recall
• Auxiliary control
• Alarm acknowledgment
Program mode provides the following functions:
• Preset (target), pattern, and scratch-pad tour programming
• Alarm monitor arming and disarming
Menu mode enables operators to set up the parameters of the connected switching system.
Note: The ADTTE keyboard does not support the following MP48 features:
• Macro programming and recall
• VCR control
Figure 3 illustrates the features of the ADTTE
keyboard.
8200-0170-05, REV. A
Figure 3: ADTTE keyboard features
4. Zoom Buttons
(In / Out) xt
5 n
2. Keypad
3. Focus Buttons
(Near/Far)
5. Tracker Ball
LCD displays status information, the selected monitor and camera numbers, and keyboard operating status. It also displays system prompts and messages. The following illustrates the fields that normally appear on the LCD.
STS MON CAM 1234 a. The Site (STS) field shows the status of the connected switching system. b. The Monitor (MON) field shows the monitor number currently under keyboard control. c. The Camera (CAM) field shows the camera number currently under keyboard control. d. The Entry field shows the numbers being entered on the keypad. e. The Status field shows the current operating state of the system. During normal operation (Program mode), “P” appears in this field. During system menu programming, “M” appears in this field.
During keyboard lock mode, “L” appears in this field.
keypad enables you to call up video from individual cameras and control their preprogrammed movement. It also provides for camera iris control, auxiliary control, monitor
focus buttons enable you to control a camera's focus setting.
zoom buttons enable you to control a camera's zoom setting.
Tracker Ball provides variable speed control of a camera's pan and tilt.
Figure 4 illustrates the locations of the buttons on
the ADTTE keypad.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
4 of 43
8200-0170-05, REV. A
Figure 4: Keypad button locations
Y
X
A
B
C
W
S
R
V
U
T
F
1
F
2
Prog
User
Site
Last
On
Off
Run
Hold
Salvo
Mon Arm
1
4
7
2
5
8
3
6
9
0
Next Clear
On
PG-LEFT
Auxiliary
Off
PG-RIGHT
Shot
Enter
Pattern
Exit
Menu
+
-
Close
PG-UP
Iris
Open
PG-DN
Lock
Pswd
Config
Ack
D
I
H
E
F
G
Q
P O N
A. Numeric Keypad: Keys ranging from 0 to 9 that enable the user to enter numbers assigned to specific cameras, monitors, salvos, tours, presets, patterns, auxiliaries, sites, and macros.
B. +: Multi-function key that is used with the
Config button to increase selected ADTTE settings. When used with the Shot function, enables preset programming.
C. –: Multi-function key that is used with the
Config button to decrease selected ADTTE settings. When used with the Shot function, enables preset recall.
D. Lock: Multi-function key used to toggles the lock state of the keyboard when the password is entered. When used in conjunction with camera selection, toggles the camera control lock.
E. Auxiliary OFF (Page Left): Multi-function key that is used to deactivate an auxiliary device in
Monitor Operate mode. Displays page to left in
Menu mode.
Auxiliary ON (Page Right): Multi-function key that is used activate an auxiliary device in
Monitor Operate mode. Displays page to right in
Menu mode.
F. Pswd: Sets or changes the keyboard lock password. There are two types of passwords:
Permanent and User Defined.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
5 of 43
M L K
J
G. Shot (Enter): Multi-function key used to recall shots (presets) in Operate mode. Used to program shots in Program mode. Used to store data in Menu mode.
Pattern (Exit): Multi-function key used to run or repeat patterns in Operate mode. Used to program patterns in Program mode. Used to exit menu programming in Menu mode.
H. Config: Used to adjust ADTTE keyboard settings, such as backlighting and key click volume.
Used to display the MP48 main menu of the attached switching system. It also enables the use of the menu programming buttons. This key is under keyboard lock protection.
J. ACK: Used to acknowledge alarms, run tours, set and repeat patterns in Operate mode.
K. Iris OPEN (Page Down): Multi-function key used to open the selected camera’s iris in
Monitor Operate mode. Displays next menu page down in Menu mode.
L. Iris CLOSE (Page Up): Multi-function key used to close the selected camera’s iris in Operate mode. Displays prior menu page up in Menu mode.
8200-0170-05, REV. A
M. (Camera): Calls the camera number entered using the numeric keypad.
N. (Monitor): Calls the monitor number entered using the numeric keypad.
O. CLEAR: Removes numbers entered on the numeric keypad.
P. NEXT (→): Multi-function key used to display the next camera in sequence during a monitor tour or an alarm tour that is on hold. Also serves as the Cursor Right function during menu programming.
Q. LAST (←): Multi-function key used to display the previous camera in sequence during a monitor tour or an alarm tour that is on hold.
Also serves as the Cursor Left function during menu programming.
R. SALVO: Used to display a pre-defined group
(salvo) of camera inputs on a group of contiguous of monitors, beginning with the currently selected monitor.
S. Site: Used to control satellite systems. This feature is not supported on the MP48 system.
T. Run (↑): Multi-function key used to start a monitor tour, universal (system) tour, or alarm tour. Also serves as the Cursor Up function during menu programming.
Hold (↓): Multi-function key used to pause a monitor tour, universal (system) tour, or alarm tour. Also serves as the Cursor Down function during menu programming.
U. User: Used to authorized users to log on to the system.
V. Mon Arm On: Used to enable system alarms to appear on monitors. This feature is under keyboard lock protection.
Mon Arm Off: Used to disable system alarms from appearing on monitors. This feature is under keyboard lock protection.
W. Prog: Used to program monitor tours and other system programming features. This button is under keyboard lock protection.
X. F2: Function key whose use varies depending upon the feature being accessed.
Y. F1: Function key whose use varies depending upon the feature being accessed.
The F1 button is also used to set the baud rate and display the firmware version information for the ADTTE.
Identifying the ADTTE
Operating Mode
The current operating mode of the ADTTE keyboard can be determined by looking at the lower-right corner of the LCD.
Table 1: ADTTE modes
Display Reading Mode
STS MON CAM 1234
005 168 -L
L: Keyboard Lock mode.
Only basic functions available.
STS MON CAM 1234
005 168 +P
+P: Programming mode.
When + is displayed,
Presets can be programmed.
STS MON CAM 1234
005 168 -P
-P: Program Recall mode.
When – is displayed, Presets cannot be programmed, only recalled.
STS MON CAM 1234
005 168 -M
M: Menu mode.
Multi-function keys provide secondary functions.
See the following sections:
General User Tasks ...................................... 7
Working in Keyboard Lock Mode ................ 7
Working in Program Mode ......................... 14
Working in Menu Mode............................... 22
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
6 of 43
8200-0170-05, REV. A
General User Tasks
The following tasks can be performed regardless of the keyboard lock setting.
• Log On
• Log Off
Logging On
If UC appears in the Camera display of your keyboard, User Codes and Passcodes have been implemented at your facility. You must log on before attempting to use the system.
Note: MP48 provides a default passcode for user
1. The default passcode is 914365. To prevent unauthorized use of the system, this passcode
should be changed. See Changing User
1. UC (User Code) appears on the LCD.
2. Enter the User Code (1-64). Press User.
3. PSC (Passcode) appears on the LCD.
4. Enter the passcode (up to 6 digits). Press
User.
Once logged on, you can begin performing other tasks.
Logging Off
When the MP48 system is not in use, you should log off the system. This will ensure that unauthorized users cannot control your system.
1. Enter 99.
2. Press F1 (located to the left of the LCD display.
Enter 99 then press F1 to log off.
F
2
F
1
STS MON CAM 99
005 168
3. UC (User Code) appears on the LCD to indicate successful log off.
-L
Working in Keyboard Lock
Mode
STS MON CAM 1234
005 168 -L
When the keyboard is in the Lock mode, the following MP48 tasks can be performed.
Table 2: Operate Mode Tasks
Task Page
Controlling Cameras and Domes 9
Controlling Auxiliary Devices 12
Note: These tasks may also be performed using programming mode. However, users without programming privileges are limited to performing only these tasks.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
7 of 43
8200-0170-05, REV. A
Selecting Monitors
Monitors display the video from the cameras and domes installed in local and/or satellite facilities.
Each monitor has an identification number used for video call up. Up to 16 monitors can be installed.
1. Enter the monitor identification number.
2. Press (Monitor). The monitor identification number appears in the MON field of the LCD.
The selected monitor is under keyboard control.
Camera video can now be viewed on the called monitor.
On-Screen Information
When monitors 1-8 are selected, a text overlay appears on the selected video. There are two
display formats available. See Figure 5 and
Figure 5: Monitor Display Format #1
C
A
B
0001
HOLD
LOBBY
ENTRANCE
14: 25: 33
03- 15- 03
D
E
Figure 6: Monitor Display Format #2
D
14: 25: 33 03- 15- 03 E
B
A
0001 HOLD LOBBY ENTRANCE
C
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
The following information is displayed:
A. Camera Number: Number assigned to the camera whose video is displayed. Either the real number based on the input connection or a pseudo number (1-9999) may be displayed.
B. Status Line: This shows current information about system operation. Information displayed may include day of week, monitor arming codes, dwell times, and messages related to tours, salvos and alarms. Appendix B of the
“MegaPower 48 Programming and Operation
Manual” includes a complete list of the status messages.
C. Camera Title: Up to 16 characters may be used for the camera title. Depending on the format selected, the title may appear on one or two lines.
D. Time: This is the current time in 24-hour format set using the menus.
This is the current date set using the menu function.
Selecting Cameras and Domes
Once a monitor is selected, you may call camera or dome video to the monitor. Each system camera has a unique identification number documented by the system administrator.
1. Enter the camera identification number.
2. Press (Camera). The camera identification number appears in the CAM field of the LCD.
The selected video input now appears on the selected monitor screen. Depending upon the camera type, you may be able to control the pan, tilt, zoom, focus, and iris settings.
Locking Cameras and Domes
Cameras can be “locked” to prevent other keyboard operators from controlling their movements. If a camera is locked, other operators with the same or lower priority will be able to view the camera, but will not be able to control its pan, tilt, zoom, focus, iris, preset, and auxiliary functions. When an operator calls a camera that has been locked out, the word
“LOCK” appears on the monitor’s status line.
An operator with a higher priority level than the operator who locked the camera can gain control of the camera.
Lock is used to lock or unlock the selected camera.
8200-0170-05, REV. A
8 of 43
Note: You may also use the F1 function key to lock and unlock the selected camera.
Command Function
2- F1 Lock the camera
1- F1 Unlock the camera
Controlling Cameras and Domes
With the ADTTE keyboard, you can control the pan, tilt, zoom, focus and iris settings for appropriately equipped cameras.
Using the Tracker Ball
The Tracker Ball controls the panning and tilting of cameras connected to the switching system. To control pan/tilt direction:
• Move the Tracker Ball left or right for pan control.
• Move the Tracker Ball towards (down) or away from (up) for tilt control.
Figure 7: ADTTE Tracker Ball control pan/tilt movement
Tilt Up
Tracker Ball
Pan
Left
Pan
Right
Tilt Down
When the Tracker Ball is moved diagonally, the camera pans and tilts in the direction the Tracker
Ball moves.
Figure 8: ADTTE Tracker Ball control diagonal movement
Move up to left
Move up to right
Move down to left
Move down to right
Note: For cameras with variable speed pan/tilt capability, camera movement speed is proportional to the positioning of the Tracker Ball. The further from the stationary center position the Tracker Ball travels, the faster the camera moves. Eight independent speed levels are available for the up, down, left, and right directions.
When the camera has been positioned appropriately, release the Tracker Ball to the center position.
Controlling Zoom and Focus
The zoom and focus controls are located to the left and right of the Tracker Ball.
Command Function
Zoom In Increase magnification
Zoom Out
Focus Far
Decrease magnification
Adjust clarity for distant objects
Focus Near Adjust clarity for nearby objects
Figure 9: ADTTE zoom and focus controls
Zoom In
(tele)
Focus Far
Zoom Out
(wide)
Focus Near
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
9 of 43
8200-0170-05, REV. A
Adjusting Iris Settings
Normally, the brightness of a picture is controlled by the camera's auto gain and the auto/manual iris functions. The Iris Control keys allow you to manually adjust the brightness or darkness of an image. These keys are located to the right of the numeric keypad, next to the camera key.
Figure 10: Iris control keys
Camera
Close
PG-UP
Iris
Open
PG-DN
Command Function
Iris Open Brightens image
Iris Close Darkens image
Note: SpeedDome Ultra dome units are designed with Auto Focus and Auto Iris capability. After performing manual focus or iris adjustments, the auto control mode may be resumed by pressing the
Iris Open and Close keys simultaneously.
Flipping Domes
The “flip” command allows you to instantaneously rotate the dome 180° from its current pointing position.
Command Function
19-F1 Flip dome
IMPORTANT!
On suitably equipped domes with the auto-flip function enabled, the dome flips automatically when the Tracker Ball is held in the tilt down position and the dome reaches its lower tilt limit.
Calling Presets
A preset is a memorized location or scene that a pan/tilt camera or dome can display on demand.
Presets are also referred to as shots or targets.
The Shot (Preset) key is located to the right of the numeric keypad.
Figure 11: Shot (Preset) and Pattern keys
Shot
Enter
Pattern
Exit
To call a preset:
1. Press – (to the right of the LCD). This ensures that the Touch Tracker is in recall mode.
2. Call the camera or dome that will display the preset.
3. Enter the preset identification number.
4. Press Shot.
The selected scene now appears on the monitor with appropriate pan, tilt, zoom, and focus adjustments.
Running Patterns
A pattern is a sequential series of pan, tilt, zoom, and focus commands defined for SpeedDome series domes, and are programmed in real time.
The Pattern key is to the right of the numeric keypad
Running Patterns One Time
– (to the right of the LCD). This ensures that the Touch Tracker is in recall mode.
2. Call the dome that will run the pattern.
3. Enter the pattern number (1-3).
Pattern. Depending upon the pattern number entered, P-1, P-2, or P-3 appears on the LCD. keypad). The camera runs through the pattern movements once.
Note: If the selected pattern has not been programmed, the default “Apple Peel” pattern runs.
Repeating Patterns
– (to the right of the LCD). This ensures that the Touch Tracker is in recall mode.
2. Call the dome that will run the pattern.
3. Enter the pattern number (1-3).
Pattern. Depending upon the pattern number entered, P-1, P-2, or P-3 appears on the LCD.
Ack (located in the lower right corner of the keypad).
The pattern runs repeatedly until a camera command (pan, tilt, zoom, focus or iris) is issued.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
10 of 43
8200-0170-05, REV. A
Holding Patterns
– (to the right of the LCD). This ensures that the Touch Tracker is in recall mode.
2. Call the dome that will run the pattern.
3. Enter the pattern number (1-3).
Pattern. Depending upon the pattern number entered, P-1, P-2, or P-3 appears on the LCD.
Hold (located to the left of the numeric keypad). The camera moves to the start of the selected pattern and holds. Then follow the instructions for running or repeating a pattern when ready to do so.
Patterns and Older SpeedDome
Camera Domes
If you cannot get patterns to work with older series
SpeedDome camera domes, try using the function keys to access the patterns.
Note: Verify that the keyboard is in normal operating mode—Lock (-L) or Program Recall (-P)—
before performing this task. See Unlock/Lock the
Table 3 lists the pattern function key commands.
Table 3: Pattern Function Keys
Command Function
21-F1 Run Pattern 1
22-F1 Run Pattern 2
23-F1 Run Pattern 3
41-F1 Repeat Pattern 1
42-F1 Repeat Pattern 2
43-F1 Repeat Pattern 3
31-F1 Go to (hold) Pattern 1
32-F1 Go to (hold) Pattern 2
33-F1 Go to (hold) Pattern 3
Controlling Tours
A tour is a dynamic sequence of camera views or patterns, each of which appears on a selected monitor screen for a specified dwell time. In addition, each preset or pattern can have a preprogrammed preset status, auxiliary status, and connect next designation. The Run and Hold keys are located to the left of the numeric keypad. The
Next and Last keys are located in the lower left corner of the keypad. Relative positions of the Tour
control keys are shown in Figure 12.
Figure 12: Tour control keys
Run
Starts Tour
Displays previous scene
Last Next
Hold
Displays subsequent scene
Pauses
Tour
Additionally, there are monitor or "scratch-pad" tours, which are temporary tours programmed for the currently selected monitor.
Running System Tours
1. Select the monitor where the tour will run.
2. Enter the system tour number to be associated with the monitor under control.
3. Press Run, and then press Ack within three seconds to run the designated system tour.
Note: Tour direction can be changed while a tour is in progress. To change the direction of a running tour, press Next or Last, depending on which is appropriate in a given situation.
Holding Tours
A tour can be stopped and held on a single camera entry by pressing Hold. While a tour is on hold, all keyboard control actions (pan, tilt, lens adjustment, and auxiliary on/off functions) can be performed on the held camera. You may also step forward and backward through the cameras in the tour by pressing Next or Last.
Re-Starting Tours
• To re-start a held tour in the forward direction,
Press Run.
• To re-start a tour in the reverse direction, press
Last, followed by Run.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
11 of 43
8200-0170-05, REV. A
Controlling Auxiliary Devices
An auxiliary is a relay that controls devices such as lights, door locks, and audible alarms. Auxiliary devices are also called output devices. Use the
Auxiliary On and Off keys (located to the right of the numeric keypad) to control the devices.
Figure 13: Auxiliary Control keys
On
PG-LEFT
Auxiliary
Off
PG-RIGHT
Auxiliary devices may be momentary or latched. A
momentary auxiliary remains active as long as its control key is pressed. An example of momentary auxiliary action is a door that remains unlocked as long Auxiliary On is pressed. When released, the door returns to its locked state.
A latched auxiliary remains active until it is deactivated using the appropriate off switch. An example of a latched auxiliary is a light. When
Auxiliary On is pressed (and released), the light is turned on. When Auxiliary Off is pressed (and released), the light is turned off.
IMPORTANT!
The number of available auxiliaries depends on the dome type. Outdoor SpeedDomes have only one auxiliary connection. Indoor
SpeedDomes have four auxiliary connections. If you are unsure about the number of available outputs on the device, refer to your operator’s manual.
To control an auxiliary:
1. Call the camera associated with the appropriate relay.
2. Enter the auxiliary number (1-4).
3. Press Auxiliary On to activate the auxiliary.
Note: When Auxiliary On is released, a latched auxiliary remains activated. A momentary auxiliary is deactivated.
4. To de-activate a latched auxiliary, press
Auxiliary Off.
Acknowledging Alarms
System cameras may be associated with alarm contacts connected to key security points. If an alarm is activated, the camera scene associated with the alarm appears on a system monitor or monitors that are armed for alarm display. When the alarm camera scene appears on the monitor screen, the word “ALARM” appears on the monitor’s onscreen status line. If an alarm title has been programmed, the alarm title also appears in the alarm title area.
Some system monitors are armed for automatic or delayed automatic clearance. Monitors armed for manual clearance (acknowledgment) can be cleared from a keyboard controller pressing Ack (located in the lower right corner of the keypad).
Figure 14: Alarm Acknowledge key
Ack
Acknowledging Single Alarms
1. Call the monitor that is displaying the alarm video.
2. Press Ack.
Acknowledging an Alarm Salvo
1. Call the first (lowest numbered) monitor in the alarm group (salvo).
2. Press Ack.
Acknowledging Sequencing Alarms
If a monitor is cycling through a sequence of multiple alarm scenes, do the following:
1. Hold or step to (press Next or Last) the first alarm to be cleared.
2. Press Ack.
3. Repeat steps 1 and 2 for each alarm in the sequence until all alarms are cleared.
Acknowledging a Wired Set
A wired set is a set of alarm contacts such that when any one member of the set is activated, all of the members are activated.
To acknowledge the wired set:
1. Call the monitor associated with the alarm contact.
2. Press Ack.
All alarms in the wired set are cleared when this alarm is cleared.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
12 of 43
8200-0170-05, REV. A
Running Salvos
A salvo is a group of camera scenes that can be called for simultaneous display on a contiguous group of monitors. Up to 64 salvos may be programmed. The Salvo key is located to left of the numeric keypad beneath the Run and Hold keys.
Figure 15: Salvo key
Run
Hold
Salvo
To call a salvo:
1. Enter the number of the first (lowest numbered) monitor in the salvo group.
2. Press (Monitor).
3. Enter the salvo number (1-64).
4. Press Salvo. The salvo will appear on the appropriate monitor group.
The first monitor of the salvo group displays “HOLD” on the status line. The remaining monitors in the salvo group display “SALVO”.
Note: If a salvo is called in response to a system alarm, the first monitor of the salvo group displays
“ALARM” on the status line. The remaining monitors in the alarm salvo group display “SALVO”.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
13 of 43
8200-0170-05, REV. A
Working in Program Mode
Unlocking the Keyboard
STS MON CAM 1234
005 168 +P
STS MON CAM 1234
005 168 -P
1. Enter the keyboard lock password.
2. Press Lock (located on the on the right side of the keypad).
The lower right corner of the LCD displays P, indicating that programming mode is active.
Note: The keyboard lock must be disabled to use this feature. To disable the keyboard lock, see
When the ADTTE keyboard is in Program mode, the following MP48 programming tasks can be performed.
Locking the Keyboard
When programming tasks are finished, lock the keyboard.
1. Enter the keyboard lock password.
2. Press Lock.
Table 4: Program Mode Tasks
The lower right corner of the LCD displays L, indicating that that the keyboard lock is active.
Task Page
Pattern Programming
Three patterns may be programmed for each
SpeedDome programmable dome. Pattern length and complexity are limited by two variables:
• The number of available camera commands
• Time
In addition, the following system settings can be configured via the keyboard.
Each time you move the camera in any direction
(with zoom, focus, or iris adjustments), you issue a command to the camera. The three patterns for a dome can collectively consist of up to 98 camera Table 5: Program Mode System Setup Tasks commands.
There is also a pattern time limit. A single pattern
Adjusting Text Display Position
cannot have a duration longer than 400 seconds.
Regardless of the number of commands issued, a pattern stops recording once the time limit has elapsed.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To program a pattern:
1. Press + located to the right of the LCD.
Unlock/Lock the Keyboard
Before any programming tasks can be performed, you must first unlock the keyboard by entering the keyboard lock password. When the ADTTE keyboard is first installed, the default password
1953 is active. For security purposes, the default
password should be changed. See Changing the
Keyboard Lock Password on page 20.
2. Select the camera where the pattern will be saved.
3. Enter the pattern number (1-3), and press Pattern.
IMPORTANT!
With SpeedDome Ultra series domes, a progress bar displays showing the remaining number of programming steps available. The progress bar decreases as the pattern commands are used. In addition, the dome moves very slowly during patterns and cannot be adjusted.
4. Press Prog. Using the Tracker Ball and lens control keys, maneuver the called camera to define the pattern.
5. When finished programming the pattern, press
Ack to save.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
14 of 43
8200-0170-05, REV. A
Pattern Programming for Older
SpeedDome Series Domes
If you have older SpeedDome series domes installed at your facility, use the following procedure.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
1. Select the camera that will be used for programming the pattern.
2. Enter a pattern programming command:
Command Function
121-F2 Program Pattern 1
122-F2 Program Pattern 2
123-F2 Program Pattern 3
3. Using the Tracker Ball and lens control keys, maneuver the called camera to define the pattern.
4. Enter 120, and press F2 to end the pattern definition.
5. Enter 130, and press F2 to save the pattern.
Programming Preset Scenes
Certain cameras with pan/tilt and motorized lens capability can be programmed to immediately move to specific pan, tilt, zoom, and focus positions when called by a keyboard.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To program a preset scene:
2. Select the camera where the preset will be saved.
3. Adjust the camera to the desired scene using the Tracker Ball and lens control keys.
4. Enter the preset number (1-96), and press
Shot.
Programming Monitor Tours
A monitor (“scratch pad") tour is a temporary sequence of camera views programmed for the selected monitor. A monitor tour can contain up to
64 camera scenes sequenced in any order. Each scene is shown for a specified duration called the dwell time.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
15 of 43
To program a monitor tour:
1. Select the monitor where the tour will run.
2. Enter 62, and press Prog (located above the keyswitch). This clears any previously programmed monitor tour.
3. Enter the first camera number to include in the tour, and press (Camera).
4. Enter the dwell time (1-60), and press Prog.
5. Repeat steps 4 and 5 until all the cameras in the tour have been programmed. When finished, continue with step 6.
6. Press Hold or Run to exit the monitor tour programming mode.
Command Function
Run Starts the tour from the beginning.
Hold Leaves the tour on hold at the most recently displayed camera.
Monitor Tour Programming Options
When a tour is running, press Hold to stop the tour and hold the currently displayed camera. While the tour is on hold, it can be re-programmed to add a camera, remove a camera, or change the dwell time.
Note: Verify that the keyboard is in programming mode before performing these tasks. See
Unlock/Lock the Keyboard on page 14.
Adding a Camera to a Tour
1. Press Next until the desired camera scene is displayed, and then press Hold.
2. Call the camera to be inserted in the tour.
3. Enter the desired dwell time (1-60), and press
Prog to set.
4. Press Hold or Run to exit tour programming mode.
Removing a Camera from a Tour
1. Press Next until the desired camera scene is displayed, and then press Hold.
2. Enter 0, and press Prog to erase the currently displayed tour entry.
3. Press Hold or Run to exit tour programming mode.
8200-0170-05, REV. A
Changing the Dwell Time for a Tour Entry
1. Press Next until the desired camera scene is displayed, and then press Hold.
2. Enter 0 to erase the current dwell time.
3. Enter the new dwell time (1-60), and press Prog to set the new dwell time.
4. Press Hold or Run to exit tour programming mode.
Clearing a Monitor Tour
Enter 62 and press Prog to clear the previously programmed monitor tour.
Monitor Arming
Armed monitors are system monitors that are configured to display alarm signals as they occur.
By arming a monitor, you define how it will display, queue, and clear incoming alarms. Before arming a monitor, you must understand the alarm display, queue, and clearance methods.
Alarm Display Methods
Three alarm display methods are available: Single,
Dual, and Block Display.
Single Display: Incoming alarms are displayed on a single monitor. Multiple alarms received at a single monitor will be displayed in sequence based on the monitor’s queuing method.
Dual Display: Incoming alarms are displayed on a pair of monitors. The hold monitor receives the first of a series of alarms. The sequence monitor receives subsequent and queues the incoming alarms. After an alarm is cleared on the hold monitor, the first alarm in queue on the sequence monitor is moved to the hold monitor for viewing and clearance.
Block Display: Incoming alarms are displayed on a group (block) of monitors. The first incoming alarm is displayed on the first (lowest numbered) monitor of the block. The second alarm is displayed on the next lowest numbered monitor of the block, and so on. When all monitors in a given block are displaying alarm video signals, all subsequent alarms are held in queue until displayed alarms are cleared.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
Alarm Queuing Methods
Two alarm queuing methods are available:
Sequence and Hold Queuing.
Sequence Queuing: Incoming alarms are displayed in sequence on an armed monitor and cycle continuously until each alarm is cleared. Each alarm is displayed for a pre-designated dwell time.
Hold Queuing: An incoming alarm is displayed and held on an armed monitor until it is cleared. All subsequent alarms are queued in order until the current held alarm is cleared.
Alarm Clearance Methods
Three alarm clearance methods are available:
Manual, Instant, and Auto Clear.
Manual Clear: Pressing Ack clears an alarm.
Instant Clear: An alarm is reset immediately at its source (if the alarm has not already been manually acknowledged). For example, a door opens and activates an alarm. Closing the door clears the alarm instantly.
Auto Clear: An alarm is reset at its source after a
20 second delay (if the alarm has not already been manually acknowledged). For example, a door opens and activates an alarm. The door is immediately closed, but the alarm will not clear unless the door remains closed for a 20 second interval.
Monitor Arming Codes
Arming codes are derived from the different combinations of display, queuing, and clearance methods. Based on the combinations, there are 16 codes, each with its own number and a three or four letter acronym ID. The default arming code for all monitors is disarmed.
Table 6: Monitor Arming Codes
Display / Queuing /
Clearance
Code Command
Single / Sequence / Instant SSI
Single / Sequence / Auto SSA
1-Mon Arm On
2-Mon Arm On
Single / Sequence / Manual SSM 3-Mon Arm On
Single / Hold / Instant
Single / Hold / Auto
Single / Hold / Manual
SHI 4-Mon Arm On
SHA 5-Mon Arm On
SHM 6-Mon Arm On
Block / Sequence / Instant BSI
Block / Sequence / Auto BSA
7-Mon Arm On
8-Mon Arm On
Block / Sequence / Manual BSM 9-Mon Arm On
Block / Hold / Instant BHI 10-Mon Arm On
8200-0170-05, REV. A
16 of 43
Display / Queuing /
Clearance
Block / Hold / Auto
Block / Hold / Manual
Dual / Hold / Instant
Dual / Sequence / Instant
Dual / Hold / Auto
Dual / Sequence / Auto
Dual / Hold / Manual
Dual / Sequence / Manual
Disarm Monitor
Enable Manual Override
Disable Manual Override
Display Arming Status
Code Command
--
--
--
BHA 11-Mon Arm On
BHM 12-Mon Arm On
13-Mon Arm On DHI
DSI
DHA
DSA
14-Mon Arm On
15-Mon Arm On DHM
DSM
-- 16-Mon Arm On or Mon Arm Off
17-Mon Arm On
18-Mon Arm On
0-Mon Arm On
IMPORTANT!
If a dual display code [13-15] is selected, the second (sequence) monitor is automatically selected after the first (hold) monitor is armed. The sequence monitor number will always equal the hold monitor number + 1.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To arm a monitor:
1. Call the monitor to be armed.
Note: To display the current arming status, enter
0, and press Mon Arm On.
2. Select the desired arming code from Table 6.
3. Enter the command number (1-18), and press
Mon Arm On. The code letters will be displayed for five seconds in the on-screen status line.
Note: Selecting a monitor (1-16), and pressing Mon
Arm On. This activates the arming method
designated by using the Monitor menu (page 27).
Option for Manual Override
Any monitor assigned for instant or auto clearance can be additionally enabled for manual override.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To enable or disable manual override:
1. Call the desired armed monitor.
2. Do one of the following:
Command Function
17-Mon Arm On Enable manual override
18- Mon Arm On Disable manual override
Any monitor armed for manual clearance will display a four-letter code acronym with “A” (acknowledge) as its fourth or right-most code letter.
Disarming a Monitor
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
1. Clear all currently active alarms.
2. Select the monitor you want to disarm (1-16).
3. Press Mon Arm Off.
Note: You can also disarm a monitor using the arming code. Select the monitor you want to disarm, enter 16 and press Mon Arm On.
Resetting the System
!
WARNING: Resetting the MP48 clears all programmed information about the system. Before performing this task, backup your settings using the S3 software.
To clear all previously programmed information, and reset the system to its original default settings, perform a system reset.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
1. Enter 55 and press F2.
2. Enter 99 and press F2.
Note: Step 2 must be performed within 3 seconds of performing step 1 or the reset will not occur.
Setting the Date Format
Note: This procedure may also be performed
through the menus. See Changing Time and Date
There are three options for the on-screen date format:
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
8200-0170-05, REV. A
17 of 43
To set the date format from the keyboard:
Enter a date format commands.
Command Function
21 - F2
22 - F2
Sets MM-DD-YY format
Sets DD-MM-YY format
23 - F2
24 - F2
Sets YY-MM-DD format
Toggle through date formats
Note: The default date display format is MM-DD-YY.
Adjusting Text Display Position
IMPORTANT!
This procedure applies to monitors with on-screen text displayed using Format 1
(Figure 5). On-screen text cannot be adjusted on monitors using Format 2 (Figure 6).
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To adjust the text home positioning:
1. Select the monitor requiring text display adjustment.
2. Enter 50 and press F2. This enables the Tracker
Ball for text positioning to the "home" position.
3. Move the Tracker Ball to adjust the positioning of the text overlay
4. Enter 51 and press F2 when finished.
Detecting Camera Video Loss
The MP48 system has built-in video loss detection.
Video loss is determined by the absence of a video sync signal at any of the 48 video inputs on the patch panel. Loss of the sync signal would occur if a camera is malfunctioning, disconnected, or if the camera cable is cut.
IMPORTANT!
If video loss detection is enabled for any video input, video output 16 cannot be used for switching. Video output 16 is used to sample video when video loss detection is enabled.
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To set the video loss detection mode:
1. Select or hold the desired camera whose video loss detection you want to change.
2. Enter video loss detection command.
Table 7: Video Loss Detection Commands
Command Function
100 - F2 Disables video loss detection for the camera.
101 - F2 Enables sync loss detection (SYNC
ONLY) for the camera.
105 - F2 Enables automatic video loss detection for the camera.
106 - F2 Enables automatic video loss detection for all system cameras.
108 - F2 Clears video loss settings for all cameras.
111 - F2 Prints the current video loss detection mode of the selected camera.
112 - F2 Prints the current video loss detection mode of all system cameras.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
18 of 43
8200-0170-05, REV. A
Audio Alarm Programming
The ADTTE keyboard can be programmed to provide an audio tone when an alarm is received at an armed monitor under keyboard control. The system default setting is audio enabled (ON) for all system keyboards. Audio alarm signals can be enabled or disabled through a keyboard, a keyboard port, or system wide.
Enabling/Disabling Keyboard Port Audio
Alarms
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To enable/disable an audio alarm for a single keyboard port (up to four individual keyboards), enter an audio alarm command.
Table 8: Audio Alarm Commands (single keyboard port)
Command Function
48 - F2
47 - F2
Enables audio alarms for the keyboard port
Disables audio alarms for the keyboard port
System Wide Audio Alarm Programming
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
To enable/disable audio alarm for all keyboard ports, enter an audio alarm command.
Table 9: Audio Alarm Commands (all keyboard ports)
Command Function
46 - F2 Enables audio alarms for all keyboard ports
45 - F2 Disables audio alarms for all keyboard ports
Transferring System Data
System data can be transferred from the MP48 system to a flash memory module in the patch panel section of the assembly. Data can also be transferred back to the system from the memory module.
IMPORTANT!
In order for a system data transfer to be performed, System Reset privileges must be enabled when defining the priority level for a user or keyboard. For details on priority programming, see
Configuring Priority Settings on page 32.
Transferring System Data to the Memory
Module
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
1. Enter 55, and press F2.
IMPORTANT! Step 2 must be performed within
3 seconds.
2. Enter 140, and press F2.
If step 3 is not performed within the 3-second interval, the data transfer will not take place.
Transferring System Data from the
Memory Module
Note: Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
1. Enter 55 and press F2.
IMPORTANT! Step 2 must be performed within
3 seconds.
2. Enter 141 and press F2.
If step 3 is not performed within the 3-second interval, the data transfer will not take place.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
19 of 43
8200-0170-05, REV. A
Changing ADTTE Keyboard
Settings
Use the following procedures to change settings specific to the ADTTE keyboard.
Table 10: ADTTE Keyboard settings tasks
Task Page
Turning Keyboard Repeat Off 20
Changing the Keyboard Lock Password
Adjusting the Key Click Volume
Turning Key Click Sound On/Off
Changing the Language Setting 21
Displaying the Touch Tracker Baud Setting 21
Displaying the Firmware Version
Turning Keyboard Repeat Off
The ADTTE keyboard must have keyboard repeat turned off to work with the MP48 system. To turn off keyboard repeat, enter 200 and press F1.
IMPORTANT! The default setting of the ADTTE keyboard is keyboard repeat on.
Note: Older versions of the ADTTE keyboard do not allow for changing the repeat mode. Verify that the firmware version for the keyboard is F01F-2840-0106
and 0701-2839-0102 or newer. See Displaying the
Firmware Version on page 21 for procedure.
Changing the Keyboard Lock
Password
Passwords allow you to limit access to advanced system features, such as arming or disarming monitors and the dual function menu programming keys (such as, PG-DN, PG-UP). Passwords can be
1 to 4 digits in length with the valid values being 0-
9998. The default password is set to 1953.
IMPORTANT!
If you do not change the default password, anyone who knows the default password will be able to gain access to the advanced features of the ADTTE keyboard.
To set or change the password:
1. Press Pswd. Enter Old PSWD appears on the
LCD.
2. Enter the current password and press Pswd.
Enter New PSWD appears on the LCD.
3. Enter the new password and press Pswd.
ReEnter PSWD appears on the LCD.
4. Enter the new password again. Press Pswd when finished. If the password successfully changed, Successful PSWD appears on the
LCD.
Note: The keyboard beeps if the password change was unsuccessful. The LCD refreshes and displays the status fields. If this happens, return to step 1 and repeat the process.
5. Press Clear to refresh the LCD.
Adjusting the LCD Brightness
1. Press number 1, and then press Config.
2. Use the + and – buttons (located near the right side of the LCD) to adjust the brightness setting.
• Press + to make the LCD backlighting brighter.
• Press – to make the LCD backlighting dimmer.
3. When the backlighting is at the preferred level, press Clear to refresh the LCD.
Turning Key Click Sound On/Off
1. Press number 3, and then press Config to change the setting.
2. The display shows the current setting for the key click.
• Key Click On appears on the LCD when the key click is enabled.
• Key Click Off appears on the LCD when the key click is disabled.
Each time 3 and Config is pressed the setting changes.
3. Press Clear to refresh the LCD.
4. Repeat steps 2 and 3 until the preferred setting appears on the LCD.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
20 of 43
8200-0170-05, REV. A
Adjusting the Key Click Volume
1. Press number 2, and then press Config.
2. Use the + and – buttons (located near the right side of the LCD) to adjust the volume.
• Press + to make the key click volume louder.
• Press – to make the key click volume softer.
3. When the volume is at the preferred level, press
Clear to refresh the LCD.
Changing the Language Setting
The LCD information on your keyboard can be displayed in a number of languages, including:
• English
• German
• French
• Spanish
• Portuguese
• Italian
To change the language appearing on the LCD:
1. Enter 35, and then press Config.
2. Press Next to scroll through the language choices.
3. Press Ack when the correct language choice appears on the LCD.
After the keyboard resets, messages on the LCD appear in the selected language.
Displaying the Touch Tracker
Baud Setting
Enter 3 and press F1 to display the current baud setting for the ADTTE Touch Tracker.
Changing the Baud Rate
The ADTTE keyboard supports four baud rates:
1200, 2400, 4800, and 9600 baud. The default setting for the baud rate is 1200.
IMPORTANT!
If the baud rate is set incorrectly, the keyboard will not operate. Be sure that the baud rate is set to the correct value.
To set or change the baud rate:
1. Enter the baud rate (1200, 2400, 4800 or 9600).
2. Press F1 (located to left of the LCD).
No prompts appear on the screen to inform you that the baud rate has been changed.
Displaying the Firmware Version
If you should experience problems with your
ADTTE, you may need to provide information about the firmware version.
To display the firmware version:
1. Enter 100, and then press F1. Firmware information appears on the LCD.
• F represents the Flash version.
• E represents the EEPROM version.
2. Press Clear to refresh the LCD.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
21 of 43
8200-0170-05, REV. A
Working in Menu Mode
STS MON CAM 1234
005 168 -M
Note: The keyboard lock must be disabled to use this feature. To disable the keyboard lock, see
Unlock/Lock the Keyboard on page 14.
The Menu button allows you to view the main menu of the attached switching system. When the main menu for the switching system has been displayed, the functions associated with the multi-function keys are enabled. Table 10 lists the multi-function keys.
When you complete using the main menu, press
Menu. The multi-function buttons return to their normal operating mode.
To view the menus:
1. Select a text display monitor (1-8) for viewing the menus, and place the monitor on Hold.
IMPORTANT! Do not select a monitor that is running a tour or salvo, or a monitor that is in an alarm condition.
2. Press Menu.
3. If User IDs are enabled, enter the passcode for the current user to access the menus.
Once the menu is displayed, the appropriate functions on the multi-function keys are used for operating the menus.
Note: The menu functions are printed beneath the primary key function names on the ADTTE keypad appliqué.
Table 11: Multi-Function keys description
Menu
Function
Page Left
Page Right Auxiliary
Off
Page Up
Page Down
Left Arrow
←
Right Arrow
→
Key label
Auxiliary
On
Iris
Close
Iris
Open
Last Moves cursor left one character.
Next
Description
Displays the menu page to the left.
Displays the menu page to the right.
Displays prior menu page up.
Displays next menu page down.
Moves cursor right one character.
Up Arrow
↑
Run Moves cursor up one row.
Down Arrow
↓
Enter
Exit
Hold Moves cursor down one row.
Shot Displays options for a setting, and stores data entered via the menu.
Pattern Exits the current screen and returns to the previously displayed screen.
Note: The Tracker Ball may also be used to change the cursor position.
IMPORTANT! To store data in Menu mode, you may press Enter (Shot) or Ack to end the sequence.
Exiting from the Menu System
The user can exit from any menu, or exit from the menu system at any time.
Task Command
Return to a prior menu. Press Exit (Pattern)
Exit from the menu system. Press Menu
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
22 of 43
8200-0170-05, REV. A
Using the Main Selection Menu
The Main Selection menu provides access to the
MP48 features that may be configured using Menu mode.
MAI N SELECTI ON
1 SYSTEM
2 MONI TOR
3 CAMERA
4 USERS/ KEYBOARDS
6 PARTI TI ONI NG
7 ALARMS
LANGUAGE - ENGLI SH
A flashing cursor appears on-screen to indicate the current selection.
The following selections are available:
• System changes settings associated with system options, date/time, port settings, monitor status, and paging profiles.
• Monitors changes settings associated with arming type and display format for the text display monitors (monitors 1-8).
• Cameras changes settings associated with pseudo-numbering, camera titles, and preset titles.
• User/Keyboards changes settings associated with user or keyboard priorities and user passcodes.
Note: The User/Keyboard option changes based on the User IDs setting on the System
Options menu.
• Switching changes settings associated with system tours, system salvos, and event timers.
• Partitioning changes settings associated with user access to system cameras, monitors, and keyboards.
• Alarms configure alarm titles, alarm contacts, and enables alarm association with system monitors.
In addition, you can configure the language setting for displaying menus. The supported languages are:
English, French, German, Italian, Portuguese, and
Spanish.
To select a menu items:
• Enter the number associated with the menu item and press Enter (Shot).
Up (Run) or Down (Hold) to move the highlight. Press Enter (Shot) to make a selection.
• Use the Tracker Ball to move the highlight and press Enter (Shot) to make a selection.
Changing the Language Setting
The MP48 menus can be displayed in English,
French, German, Italian, Spanish, and Portuguese.
To change the language setting:
1. Move the cursor to the Language field.
2. Enter the following key combinations to select the operating language:
Language Command
English 1 - Enter (Shot)
French
German
2 - Enter (Shot)
3 - Enter (Shot)
Spanish 4 - Enter (Shot)
Portuguese 5 - Enter (Shot)
Italian 6 - Enter (Shot)
Following language selection, all menus appear in the selected language.
Changing System Settings
The System menu provides the means to configure system options, time and date, ports, monitor status, and paging profiles.
SYSTEM
1 SYSTEM OPTI ONS
2 TI ME AND DATE
3 PORTS
4 MONI TOR STATUS
5 PAGI NG PROFI LE
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
23 of 43
8200-0170-05, REV. A
Changing System Options
Use System Options to configure settings associated with user IDs, peripheral interface, and logging system and alarm status.
SYSTEM OPTI ONS
USER I DS - DI SABLED
PERI PHERAL I NTERFACE - DI SABLED
LOG STATUS - ON
LOG ALARMS - ON
The following settings can be changed:
Setting Options
User IDs Enabled: User IDs must be entered to use the keyboard
Disabled: User IDs are not required
Peripheral
Interface
Log
Status
Log
Alarms
Port 1 - 8: Video recorder control supported on specific port listed
Disabled: Video recorder control not supported
On: System status is logged
Off: System status is not logged
On: System alarms are logged
Off: System alarms are not logged
To change the settings:
1. Move the cursor to the setting you want to change.
2. Press Enter (Shot) to change the setting.
3. Press Exit (Pattern) to return to the previous menu when finished making changes.
Changing Time and Date
Settings
Use Time and Date to configure settings associated with year and date format, current date, and time.
TI ME AND DATE
YEAR FORMAT - YY/ YYYY
DATE FORMAT - MM/DD/ YY- YYYY
MONTH - 01
DAY - 01
YEAR - 2003
TI ME - 13: 16: 45
The following settings can be changed:
Setting Options
Year
Format
YY: Display 2-digit year
YYYY: Display 4-digit year
Date
Format
MM/DD/YY: Month/Day/Year
DD/MM/YY (YYYY): Day/Month/Year
Month
Day
YY (YYYY)/MM/DD: Year/Month/Day
01-12: 2-digit month identifier
Year
Time
01-31: 2-digit day identifier
00-99: 4-digit year display; only last 2 digits may be changed
Current time in hours, minutes, and seconds in 24-hour format
00-24: Hour
00-59: Minute
00-59: Seconds
To change the settings:
1. Move the cursor to the setting you want to change.
2. Do one of the following:
• Press Enter (Shot) to change the Year
Format and Date Format settings.
• Enter the number and press Enter to change the Month, Day, Year, and Time settings.
3. Press Exit (Pattern) to return to the previous menu when finished making changes.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
24 of 43
8200-0170-05, REV. A
Changing Port Settings
Use Ports to configure the baud rate, data bits, parity, stop bits, and port use for the selected port.
PORT - O1
BAUD - 9600
DATA BI TS - 8
PARI TY - NONE
STOP BI TS - 1
PORT USE - KEYBOARD
The following settings can be changed:
Setting Options
Baud 300, 1200, 2400, 4800, 9600, 19200, or 38400.
Data Bits 7 or 8
Parity None, Odd, or Even
Stop Bits 1 or 2
Port Use Alarm, Keyboard, Terminal, Printer,
Aux, Modem, Peripheral Interface
Port
See Port Usage Notes for details
about these settings.
To change the settings:
1. Move the cursor to the PORT line.
2. Enter the port number (1-8), and press Enter
(Shot). The selected port’s settings are displayed.
3. Move the cursor to the setting you want to change.
4. Press Enter (Shot) to display the available options.
5. Repeat steps 3 and 4 for each setting you want to change.
6. When finished making changes, press Exit
(Pattern) to return to the previous menu.
IMPORTANT!
Once the selections for a port have been made, do not change the settings unless the connected devices are changed as well.
Port Usage Notes
Setting Description
Alarm Use this setting when connecting the
AD2096A Alarm Interface Unit.
Keyboard Use this setting when connecting the
AD2088 keyboard or ADTTE controller. For keyboard use, set
Data Bits to “8”, Parity to “none”, and Stop Bits to “1”.
Note: When a Port Expander is used, the port Baud Rate must be set to 4800, and the keyboards’ baud rate set to 1200.
Terminal Use this setting when a personal computer is connected for uploading/downloading system setup information via the S3 software.
Printer
Aux
Modem
Port 8 only
Use this setting when an RS-232 serial printer is connected.
Use this setting when control of auxiliary devices through RS-232 communications is required.
Use this setting when paging communications with an external (AT command set) modem is required.
Peripheral
Interface
Port (PIP)
Use this setting when communication with a video recorder network is required.
Note: The Peripheral Interface Port must be enabled through the System
Options menu before port parameters can be programmed for
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
25 of 43
8200-0170-05, REV. A
Viewing Monitor Status
Use Monitor Status to determine the current camera, tour, status, and sync mode for each monitor.
MONI TOR STATUS
04
05
06
07
08
MON CAM STS TOUR SYNC
01 0024 R 02 Y
02
03
0001 H
0048 A
64
- -
N
N
0012 S
0007 S
0040 S
0005 S
0036 S
- -
- -
- -
- -
- -
Y
N
Y
N
N
No changes can be made from this screen. Two pages of information are available. Use the Page
Up (Iris Close) and Page Down (Iris Open) to view the pages.
The following information is displayed:
Setting Description
Mon Monitor Number. Page 1 displays monitors 1-8; page 2 displays monitors 9-16.
Cam
Sts
Camera number. The number displayed may be the real number or pseudo number.
Status information. The following codes appear:
• R (Run)
• H (Hold)
• A (Alarm)
• S (Salvo)
Tour
Sync
Tour number currently running or on hold.
Camera sync display code.
• Y indicates that a sync (video) signal is present.
• N indicates loss of sync.
Configuring Paging Profiles
Use Paging Profile to create special profiles for sending messages to paging devices.
EDI T PAGI NG PROFI LE - 01
1 2 3 4 5 6 7 8 9 * 0 #
PHONE NUMBER
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PERSONAL I D NUMBER
- - - - - - - - - - - - - - - -
The following settings may be configured:
Setting Options
Phone
Number
Up to 32 characters (1-9, *, #) for automatic dialing of the paging service.
Personal
ID number
Up to 16 characters used to provide an identifier to the paging service.
Prerequisites for Implementing Paging
The following prerequisites are necessary when implementing paging with the MP48.
analog telephone line must be used for dialup. MP48 paging will not work with a digital telephone line.
• An external (AT Command Set) modem
• Subscription to a telecommunications service provider. The service provider must support the
Telocator Alphanumeric Protocol (TAP). The external modem wired to the MP48 must communicate directly with the service provider’s computer.
• Personal Identification Numbers (PINs) assigned by the service provider to the remote paging devices that will receive transmissions.
Character selection
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
26 of 43
8200-0170-05, REV. A
Editing a Paging Profile
1. Position the cursor on the Edit Paging Profile field.
2. Enter a profile number (1 to 64) and press Enter
(Shot). The cursor moves to the Character
Selection line and the Phone Number field.
3. Press Next or Last to move the cursor around the Character Selection line. Press Enter (Shot) to select the highlighted character.
Note: The joystick may be used to move the cursor on the Character Selection line to highlight the character you want to use. Press
Enter (Shot) to select. Repeat until all required characters are entered.
4. Press Next to move to the next field or subsequent Paging Profile. When finished making changes, press Exit (Pattern).
Refer to Appendix G in the MP48 Programming
and Operation Manual for more information about implementing paging.
Changing Monitor Settings
The Monitor menu is used to view and/or modify each monitor’s setup programming, and to arm monitors for response to alarms.
MONI TOR - 01
ARM TYPE- DI S BLK- 1- 16 ACK- Y/ N
TOUR - 02
TOUR STATUS - HOLD
DATE TI ME - ON/ OFF
TI TLE DI SPLAY - ON/ OFF
SCREEN TEMPLATE- FORMAT 1 / 2
The following settings are available:
Setting Options
Arm Type Monitor arming type. Choose from single,
dual, block, or disable. See Monitor
Arming Codes on page 16 for more
information.
Blk Monitor Block number (1-16). The block number associates monitors together to form a monitor block for alarm call up.
Setting Options acknowledgement for instant and auto clear arming codes.
N (no): Disables manual acknowledgement for instant and auto clear arming codes.
Note: This feature must be programmed after the monitor is armed with an instant or auto clear alarm type.
Tour Indicates the system tour (1-64) currently associated with the monitor. An entry of “-
--“ indicates that a scratch pad tour or no tour is associated with the monitor.
Tour Status Run: The tour is currently running on the selected monitor.
Date Time
Hold: The tour is currently on hold for the selected number.
On: The date and time display is enabled.
Title
Display
Screen
Template
Off: The date and time display is disabled.
On: The title display is enabled.
Off: The title display is disabled.
Format 1: Style associated with display
template. See Figure 5 on page 8.
Format 2: Style associated with display
template. See Figure 6 on page 8.
To change the settings:
1. Move the cursor to the Monitor line at the top of the menu.
2. Enter the monitor number (1-16), and press
Enter (Shot). The selected monitor’s settings are displayed.
3. Move the cursor to the setting you want to change.
4. Do one of the following:
• Press Enter (Shot) to change the Arm Type,
Ack, Date Time, Title Display, and Screen
Template settings.
• Enter the number and press Enter (Shot) to change the Blk and Tour settings.
Note: Tour Status cannot be changed. This is provided for information only.
5. When finished making changes, press Exit
(Pattern) to return to the previous menu.
Note: Video output 16 (monitor 16) is used by the system to sample video. If video loss detection is enabled for any system video input, video output 16 is not available for video switching, regardless of parameters programmed through the Monitor screen.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
27 of 43
8200-0170-05, REV. A
Changing Camera Settings
The Camera menu is used to assign pseudonumbering to cameras, to program camera titles and preset titles, and to set up camera video loss detection.
CAMERA
1 PSEUDO
2 TI TLE
3 PRESET TI TLES
4 PRESET/ PRESET TI TLE NUMBERS
Assigning Pseudo-Numbering to
Cameras
Use Pseudo to assign “substitute” numbers to use when selecting cameras.
ASSI GN PSEUDO CAMERAS
REAL #
0001
0002
0003
0004
0005
0006
0007
CAMERA
PSEUDO #
0007
0002
1003
1004
0005
0006
0001
The “real” camera numbers are based on video input connection points. The pseudo numbers permits assignment of any numerical value from 1 to
9999 for any camera input. The Pseudo Number menu has multiple pages, with 12 camera numbers appearing on each page. Use Page Down (Iris
Open) and Page Up (Iris Close) to scroll through the list of cameras.
IMPORTANT!
On a system reset, all pseudo numbers are reset to the real (default) camera numbers.
To assign or change a Pseudo Camera Number:
1. Enter the Real # and press Page Up (Iris Close) or Page Down (Iris Open).
2. Enter the Pseudo number (1-9999), and press
Enter (Shot).
3. Repeat steps 1 and 2 for each pseudo camera number you want to assign.
4. Press Exit (Pattern) to return to the previous menu when finished making changes.
Note: If a pseudo number is the same as a real camera number, the system switches the two camera numbers. For example, assigning pseudo number 0025 to real camera number 0001 automatically assigns pseudo number 0001 to real camera number 0025.
Changing Camera Titles and
Video Loss Settings
Use Title to configure video loss settings and assign a title to the selected camera.
CAMERA - 0001
VI DEO LOSS - ON/ OFF
TI TLE -
- - - - - - - -
- - - - - - - -
ABCDEFGHI JKLMN cdef ghi j kl mnop qr st uvwxyz 012
3456789 <>: - . / ;
The following settings are available:
Setting Options
Video Loss ON: Loss of a video sync signal will result in an alarm.
OFF: Loss of video sync signal will not be detected.
Title 16-character name (8 characters per line) assigned to the selected camera.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
28 of 43
8200-0170-05, REV. A
To change settings:
1. Move the cursor to the CAMERA number line.
Enter the camera number (real or pseudo), and press Enter (Shot).
2. Press Enter (Shot) to toggle the Video Loss setting. When the correct setting is displayed, continue with step 3.
3. Change the camera title. a. Press Next to move to the Title field. Two cursors display: the Title Cursor and the
Selection Cursor. b. Press Next to move the Title Cursor until the correct character/position in the title is highlighted.
Note: You must start from the first character in the title and move through the text until the desired character position is selected. You cannot backspace through the title. c. Use the joystick to position the Selection
Cursor over the letter, number, or symbol to include in the title. Press Enter (Shot) to add the selected character to the title. d. Repeat steps 3b and 3c until the title is complete.
4. When finished making changes, press Exit
(Pattern) to return to the previous menu.
Changing Preset Titles
Use Preset Titles to program a 2-line, 16-character title that appears whenever a preset is displayed.
PRESET TI TLE- ????
TI TLE -
- - - - - - - -
- - - - - - - -
ABCDEFGHI JKLMN cdef ghi j kl mnop qr st uvwxyz 012
3456789 <>: - . / ;
MP48 supports up to 4096 preset titles (96 presets
X 48 cameras). See Assigning Preset Titles to
Cameras/Presets for information about assigning
the title.
To program preset titles:
1. Enter a preset title number (1-4096), and press
Enter (Shot).
2. Change the preset title: a. Move the cursor to the Title lines. Two cursors display: the Title Cursor and the
Selection Cursor.
Next to move the Title Cursor until the correct character/position in the title is highlighted.
Note: You must start from the first character in the title and move through the text until the desired character position is selected. You cannot backspace through the title. c. Use the joystick to position the Selection
Cursor over the letter, number, or symbol to include in the title. Press Enter (Shot) to add the selected character to the title. d. Repeat steps 3b and 3c until the title is complete.
3. When finished making changes, press Exit
(Pattern) to return to the previous menu.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
29 of 43
8200-0170-05, REV. A
Assigning Preset Titles to
Cameras/Presets
Each programmed preset title number must be associated with a corresponding four-digit camera
(real or pseudo) number (1-9999) and a two-digit preset number (1-96). The same preset title (and preset title number) can be used multiple times for different cameras. Use Preset/Preset Title
Numbers to assign the titles to a specific preset for a selected camera.
PRESET/ PRESET TI TLE NUMBER
03
04
05
06
07
CAMERA - 0001
PRESET PRESET TI TLE
01
02
0001 FRONT
4096 MAI N
LOBBY
ENTRANCE
???? ???????? ????????
???? ???????? ????????
???? ???????? ????????
???? ???????? ????????
???? ???????? ????????
To assign the preset title to a specific camera preset:
1. Enter a camera number (1-9999) and press
Enter (Shot).
2. Enter the preset title number (1-4096) and press
Enter (Shot).
The preset title previously programmed appears to the right of the preset title number. The title cannot be edited in this menu. The cursor automatically moves to the next preset number.
Note: Entering a preset title number greater than
4096 (such as “9999”) removes the preset title association.
3. Repeat steps 1 and 2 for each preset number associated with the designated camera number.
When finished making changes, press Exit
(Pattern) to return to the previous menu.
Configuring User or
Keyboard Settings
The Users/Keyboards menu is used to set priority levels for keyboards or users, to set user numbers and passcodes, and to configure each of the eight priority levels.
USERS/ KEYBOARDS
1 KEYBOARD ( USER)
2 PRI ORI TY
User IDs are disabled in the System Options menu, the first entry in the menu reads
Keyboard.
User IDs are enabled in the System Options menu, the first entry in the menu reads User.
Changing User Settings
If User IDs are enabled, select User to set the priority and passcodes for the 64 available users.
USER
USER # - O1
PRI ORI TY LEVEL: 8
PASSCODE:
XXXXXX
The following settings are available.
Setting Description
User # User code number being configured.
Up to 64 users may be configured.
Priority
Level
Level of user privileges. Eight levels are available.
Passcode Number that authorizes use of the system. Six digits may be used.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
30 of 43
8200-0170-05, REV. A
To change user settings:
1. Move the cursor to the User line. Enter the user number (1-64) and press Enter (Shot).
2. Enter the Priority Level (1-8) and press Enter
(Shot).
Note: Priority levels are individually configurable.
“8” represents the highest priority level; “1” represents the lowest priority. Users with higher priority levels can capture control of cameras from users with lower priority levels.
3. Set or change the Passcode for the selected user: a. Enter a passcode (6 digits maximum) and press Enter (Shot).
The system displays “VERIFY PASSCODE” on the monitor. b. Re-enter the same passcode. Press Enter
(Shot).
Note: If the code entered in step 3b does not match the code entered in step 3a, the following message is displayed: **ERROR -
REENTER PASSCODE**. Repeat steps 3a and 3b.
4. When finished making changes, press Exit
(Pattern) to return to the previous menu.
Note: The default passcode for User 1 is 914365.
This passcode should be changed to prevent unauthorized access to the system.
Changing Keyboard/Priority
Settings
If User IDs are disabled, select Keyboard to assign priority levels to the selected keyboard. All keyboards default to level “8” priority.
KEYBOARD
KEYBOARD - 01
PRI ORI TY LEVEL: 8
Keyboard Numbering
Eight RS-232 ports are provided on the rear of the system CPU module. It is possible to expand the eight ports using AD1981 Port Expanders to a maximum of 32 keyboard ports, For appropriate keyboard numbering, verify if a port expander is used with each port.
The following table shows the appropriate keyboard designations with and without port expanders.
Table 12: Keyboard Numbers
Port #
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
Port 7
Port 8
With
Expander
1-4
5-8
9-12
13-16
17-20
21-24
25-28
29-32
Without
Expander
1
5
9
13
17
21
25
29
Keep this keyboard numbering information in mind when changing keyboard priority settings.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
31 of 43
8200-0170-05, REV. A
Changing Keyboard Priority Levels
1. Enter the keyboard number (1-32), and press
Enter (Shot).
2. Enter the Priority Level (1-8), and press Enter
(Shot) to save.
Note: Priority levels are individually configurable.
In general, “8” should represent the highest priority level; “1” should represent the lowest priority level. Keyboards with higher priority levels can capture control of cameras from keyboards with lower priority levels.
3. When finished making changes, press Exit
(Pattern) to return to the previous menu.
Configuring Priority Settings
Use Priority to configure settings relating to system functions that a user or keyboard may perform.
PRI ORI TY
LEVEL 1
ADD USER Y/ N
SYSTEM RESET Y/ N
LOCK CAM ABI LI TY Y/ N
OVERRI DE N/ Y
MENU ACCESS Y/ N
CHANGE PARAMETERS Y/ N
The following settings are available:
Setting Description/Options
Level Currently selected priority level that is being configured.
Add User Y (Yes): New users can be added.
System
Reset
N (No): New users cannot be added.
Y (Yes): System reset allowed via keyboard commands.
N (No): System reset not allowed via keyboard commands.
Lock Cam
Ability
Y (Yes): Lock camera control allowed.
N (No): Lock camera control not allowed.
Setting Description/Options
Override Y (Yes): Override of keyboard/camera view and control partitioning restrictions allowed.
N (No): Override of keyboard/camera view and control partitioning restrictions not allowed.
Menu
Access
Change
Parameters
Y (Yes): Access to programming menus allowed.
N (No): Access to programming menus not allowed.
Note: Menu Access must be enabled to access the Change
Parameters setting.
Y (Yes): Changing system parameters allowed through the menus.
N (No): Changing system parameters not allowed through the menus. Menus can only be viewed.
To configure a priority level:
1. Move the cursor to the Level menu item.
2. Enter the priority level number (1-8), and press
Enter (Shot).
3. Move the cursor to the menu item you want to change. Press Enter (Shot) to change the setting.
4. Repeat step 3 for each setting you want to change.
5. When finished making changes, press Exit
(Pattern) to return to the previous menu.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
32 of 43
8200-0170-05, REV. A
Configuring Switching
Settings
Use the Switching menu to program system tours, salvos, and event timers.
1 SYSTEM TOURS
2 SYSTEM SALVOS
3 EVENT TI MERS
Programming System Tours
A system tour is a programmable sequence of camera views that can be called for display on a single monitor. Use System Tours to configure the cameras, dwell times, functions, auxiliary, and connect next settings for the 64 system tours.
SYSTEM TOURS
TOUR - O1
ENT CAM DW
01 0001 05 - - - 0-
02 0002 05 - - - 0-
03 0003 05 - - - 0-
04 0004 05 - - - 0-
N
N
N
N
05 0005 05 - - - 0-
06 0006 05 - - - 0-
07 0007 05 - - - 0-
08 0008 05 - - - 0-
N
N
N
N
The following settings are available:
Setting Description/Options
Ent Entry (1-64): Relates to the order in which items are displayed in the tour.
Cam Camera: Generally relates to a camera number, but may also represent a tour or salvo number. The CN field is used to identify if a camera, tour or salvo is called.
Setting Description/Options
Dwl Dwell time (1-61): The length of time that a camera view is displayed on the monitor(s) before switching to the next tour entry. A dwell time can range from
1 to 60 seconds. An entry of 61 will hold the current camera view displayed.
Funct
Aux
Cn
Function (PR or PT): Represents a preset (PR) or pattern (PT) that is called when a camera is selected.
Auxiliary: Activates the relay associated with the selected camera for auxiliary control. If no auxiliary action is required for the tour entry, enter a zero in this field. Relays 1-4 can be set to
“On”. Relays 1-3 can be set to “Off”.
Connect Next: Four connect next options are available.
N (no): The connect next function is not enabled. The next tour entry displays after the specified dwell time elapses. A typical system tour that shows a sequence of different camera views uses this setting.
Y (yes): Connect next calls the next tour entry to the next contiguous monitor to emulate a salvo. A dwell time is selected for the first entry.
Subsequent entries for the emulated salvo must have a zero (blank) dwell time.
S (salvo): A pre-programmed system salvo is called for the specified dwell time. The pre-programmed salvo number is specified in the CAM field.
T (tour): A different pre-programmed system tour is called. This selection links two tours together to form a larger camera sequence. A connect next selection of tour can be made only for
the last entry in a system tour.
Note: A tour cannot call itself. In addition, when a tour calls another tour, the sequence does not automatically return to the original tour unless specified by a CN entry of the tour being called.
Note: Programming examples for configuring different tour entries are found in the MP48
Programming and Operation Manual. Refer to these examples for specific details.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
33 of 43
8200-0170-05, REV. A
To program a system tour:
1. Select a tour to program. a. Move the cursor to the tour number line of the menu. b. Enter the tour number (1-64) and press Enter
(Shot).
2. Enter a camera, salvo or tour number. a. Move the cursor to the cross point of the CAM column and the appropriate entry row. b. Enter the camera, salvo, or tour number and press Enter (Shot).
3. Set a dwell time for the entry. a. Move the cursor to the cross point of the DWL column and the appropriate entry row. b. Enter the dwell time (00-61) and press Enter
(Shot).
• Use 1-60 to display the entry for the specified number of seconds
• Use 61 to hold the entry when displayed.
• Use 00 to skip an entry or when the previous Connect Next (CN) field is set to
Y.
4. Set the function to call a preset or pattern. a. Move the cursor to the cross point of the
FUNCT column and the appropriate entry row. b. Press Enter (Shot) to toggle between PR
(preset) and PT (pattern). When the appropriate function is displayed, press
NEXT. c. Enter the preset (1-96) or pattern (1-3) number for the entry. A zero entry indicates no preset or pattern.
Note: If the Connect Next field is set to S
(salvo) or T (tour), a zero value must be entered for a preset or pattern. d. Press Enter (Shot).
5. Set an auxiliary action. a. Move the cursor to the cross point of the AUX column and the appropriate entry row. b. Press Enter (Shot) to display the auxiliary options:
1 = 1 ON
2 = 2 ON
3 = 3 ON
4 = 4 ON
5 = 1 OFF
6 = 2 OFF
7 = 3 OFF
8 = 0 – (no action)
Note: If the Connect Next field is set to S
(salvo) or T (tour), do not enter an auxiliary action. c. Press Next when the correct setting is displayed.
6. Set the connect next selection. a. Move the cursor to the cross point of the CN column and the appropriate row entry. b. Press Enter (Shot) to display the connect next options or enter the number for the appropriate selection and press Enter (Shot).
1=N No link or last member of a CN salvo
2=Y Connect to next entry in a CN salvo
3=S Call a pre-programmed system salvo
4=T Call a pre-programmed system tour
7. Repeat steps 2 through 6 to program additional tour entries. When finished making changes, press Exit (Pattern) to return to the previous menu.
Programming System Salvos
MP48 supports 64 salvos that are programmed to include 16 cameras on a contiguous group of monitors. Use System Salvos to configure the specific details for the salvos.
SYSTEM SALVO
SALVO - O1
ENT CAM FUNCT AUX CN
01 0001 - - - 0N
02 0002 - - - -
03 0003 - - - -
04 0004 - - - -
05 0005 - - - -
0-
0-
0-
0-
N
N
N
N
06 0006 - - - -
07 0007 - - - -
08 0008 - - - -
0-
0-
0-
N
N
N
The following fields are displayed:
Field Description/Options
Ent Entry: Refers to the order of the cameras displayed on the contiguous monitors.
Cam
Funct
Camera: Identifies the camera or salvo number associated with each entry
Function: Represents a preset (PR) or pattern (PT) that is run for the entry if a camera is selected.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
34 of 43
8200-0170-05, REV. A
Field Description/Options
Aux Auxiliary: Activates the relay associated with the selected camera for auxiliary control. If no auxiliary action is required for the tour entry, enter a zero in this field. Relays 1-4 can be set to “On”. Relays 1-3 can be set to “Off”.
CN Connect Next: Three options are available.
N (no): The connect next function is not enabled. The salvo stops at the current position.
Y (yes): The connect next function is enabled The next camera is called to the next contiguous monitor.
S (salvo): If salvo is selected for the last entry, another pre-programmed system salvo is called, and the salvo being programmed stops at the appropriate position.
Note: Programming examples for configuring different salvo entries are found in the MP48
Programming and Operation Manual. Refer to these examples for specific details.
To program a system salvo:
1. Select a salvo to program. a. Move the cursor to the salvo number line of the menu. b. Enter the salvo number (1-64) and press
Enter (Shot).
2. Enter a camera or salvo number. a. Move the cursor to the cross point of the CAM column and the appropriate entry row. b. Enter the camera or salvo number and press
Enter (Shot).
Note: Press Enter (Shot) without entering a camera/salvo number to remove the camera entry.
3. Set the function to call a preset or pattern. a. Move the cursor to the cross point of the
FUNCT column and the appropriate entry row. b. Press Enter (Shot) to toggle between PR
(preset) and PT (pattern). When the appropriate function is displayed, press
NEXT. c. Enter the preset (1-96) or pattern (1-3) number for the entry. A zero entry indicates no preset or pattern.
Note: If the Connect Next field is set to S
(salvo), a zero value must be entered for a preset or pattern. d. Press Enter (Shot).
4. Set an auxiliary action. a. Move the cursor to the cross point of the AUX column and the appropriate entry row. b. Press Enter (Shot) to display the AUX options:
1 = 1 ON
2 = 2 ON
3 = 3 ON
4 = 4 ON
5 = 1 OFF
6 = 2 OFF
7 = 3 OFF
8 = 0 – (no action)
Note: If the Connect Next field is set to S
(salvo), do not enter an auxiliary action. c. Press Next when the correct setting is displayed.
5. Set the connect next selection. a. Move the cursor to the cross point of the CN column and the appropriate row entry. b. Press Enter (Shot) to display the connect next options or enter the number for the appropriate selection and press Enter (Shot).
1=N No link or last member of a CN salvo
2=Y Connect to next entry in a CN salvo
3=S Call a pre-programmed system salvo
6. Repeat steps 2 through 5 to program additional salvo entries. When finished making changes, press Exit (Pattern) to return to the previous menu.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
35 of 43
8200-0170-05, REV. A
Configuring Event Timers
Event timers enable the automatic call up of system tours and alarm monitor/contact groups at scheduled times and days. A maximum of 35 events can be programmed. Use Event Timers to configure the schedule associated with the event timers.
HH: MM
EDI T TI MER
EVENT TI MER
NEXT TI MER
CLEAR TI MER
ENABLE/ DI SABLE TI MER
CHANGE TI MER TO HH: MM
Setting Description
HH:MM Scheduled time for the event in 24hour format. If the event timer has not been configured, NEW appears next to the time setting.
Edit Timer Displays the schedule for running tours or alarm monitor/contact groups.
Next Timer Scrolls through the list of programmed timers and displays the enabled/disabled state.
Clear Timer Deletes the currently displayed event timer.
Enable/
Disable
Timer
Change
Timer To
HH:MM
Toggles the state of the currently displayed event timer. Either Enable
Timer or Disable Timer appears on this line.
Changes the time for the currently displayed event timer.
To create an event timer:
1. Move the cursor to the time line.
2. Enter the appropriate two-digit hour (00-24) and press Enter (Shot).
3. Enter the minutes (00 – 59) and press Enter
(Shot).
4. Edit the event timer. a. Move the cursor to the Edit Timer line and press Enter (Shot) to display the Event
Timers screen.
TI ME - 12: 00
MON S M T W T F S
001 00 00 00 00 00 00 00
002 00 00 00 00 00 00 00
003 00 00 00 00 00 00 00
004 00 00 00 00 00 00 00
005 00 00 00 00 00 00 00
006 00 00 00 00 00 00 00
007 00 00 00 00 00 00 00
008 00 00 00 00 00 00 00
TBL 00 00 00 00 00 00 00 b. Move the cursor to the cross point of the appropriate day of week and the appropriate monitor position row. Use Page Up (Iris
Close) and Page Down (Iris Open) to find the monitor if not currently displayed. c. Enter the system tour number (1-64) and press Enter (Shot). This will call the tour to the specified monitor on the scheduled day and event time.
Note: Entering 00 indicates that no tour is scheduled for the day and monitor. Enter 65 to hold the current camera on the specified monitor.
5. Define Monitor/Contact table to use with the event timer: a. Move the cursor to the cross point of the appropriate day of the week on the TBL line. b. Enter the monitor/contact table number (1-10) that you want to use, and press Enter (Shot).
Note: If - - appears in the field, the default alarm contact table is used.
6. When all changes have been made to the Event
Timer, press Exit (Pattern) to return to the previous menu.
7. To configure other Event Timers, move the cursor to Next Timer, and press Enter (Shot).
Repeat steps 1-6. Press Exit (Pattern) to return to the previous menu.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
36 of 43
8200-0170-05, REV. A
System Partitioning
Use the Partitioning menus to restrict operator keyboard access to monitors and cameras.
PARTI TI ONI NG
1 KEYBOARD / MONI TOR
2 KEYBOARD / CAMERA VI EW
3 KEYBOARD / CAMERA CONTROL
4 MONI TOR / CAMERA
Keyboard Numbering in the
Partitioning Menus
Eight RS232 ports are provided on the MP48 patch panel. The total ports can be expanded to 32 by using AD Port Expanders. In order for partitioning to work properly, you must know if Port Expanders are in use.
The following table shows the appropriate keyboard designations with and without port expanders.
Table 13: Keyboard Numbers
Port #
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
Port 7
Port 8
With
Expander
1-4
5-8
9-12
13-16
17-20
21-24
25-28
29-32
Without
Expander
1
5
9
13
17
21
25
29
Keep this keyboard numbering information in mind when changing system partitioning settings.
Partitioning Keyboards and
Monitors
Use Keyboard/Monitor to specify which keyboards have access to which monitors.
MON 01
0001 Y
0002 Y
0003 Y
0004 Y
0005 Y
0006 Y
0007 Y
0008 Y
0009 Y
0010 Y
0011 Y
0012 Y
0013 Y
0014 Y
0015 Y
0016 Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
02
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
04
Y
Y
Y
Y
Y
KEYBOARD / MONI TOR
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
03
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
05
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
06
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
07 08
Y Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
The left hand column represents monitor numbers; the top row represents keyboard numbers. Use
Page Left (Auxiliary On) and Page Right (Auxiliary
Off) to display additional keyboard numbers.
To change the partitioning setting for a keyboard and monitor:
1. Move the cursor to the cross point of the keyboard and the monitor that you want to partition.
2. Press Enter (Shot) to change the setting.
• Y (yes) indicates that a keyboard has access to a specific monitor.
• N (no) indicates that a keyboard cannot access a specific monitor.
• By default, all keyboards have access to all monitors.
3. Repeat steps 1 and 2 for each keyboard/monitor you want to change. Press Exit (Pattern) to return to the previous menu.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
37 of 43
8200-0170-05, REV. A
Partitioning Keyboards and
Camera Views
Use Keyboard/Camera View to specify which keyboards have access to which cameras.
CAM 01
0001 Y
0002 Y
0003 Y
0004 Y
0005 Y
0006 Y
0007 Y
0008 Y
0009 Y
0010 Y
0011 Y
0012 Y
0013 Y
0014 Y
0015 Y
0016 Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
02
Y
Y
Y
Y
Y
KEYBOARD / CAMERA VI EW
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
03
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
05
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
04
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
06
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
07 08
Y Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
The left hand column represents camera numbers; the top row represents keyboard numbers. Use
Page Up (Iris Close), Page Down (Iris Open), Page
Left (Auxiliary On) and Page Right (Auxiliary Off) to display additional cameras and keyboards.
To change the partitioning setting for a keyboard and camera:
1. Move the cursor to the crosspoint of the keyboard column and camera row that you want to partition.
2. Press Enter (Shot) to change the setting.
• Y (yes) indicates that a keyboard has access to a specific camera.
• N (no) indicates that a keyboard cannot access a specific camera.
• By default, all keyboards have access to all cameras.
3. Repeat steps 1 and 2 for each keyboard/camera you want to change. Press Exit (Pattern) to return to the previous menu.
Partitioning Keyboards and
Camera Control
Use Keyboard/Camera Control to specify which keyboards have control over specific cameras.
CAM 01
0001 Y
0002 Y
0003 Y
0004 Y
0005 Y
0006 Y
0007 Y
0008 Y
0009 Y
0010 Y
0011 Y
0012 Y
0013 Y
0014 Y
0015 Y
0016 Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
02
Y
Y
Y
Y
Y
KEYBOARD / CAMERA CONTROL
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
03
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
05
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
04
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
06
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
07 08
Y Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
The left hand column represents camera numbers; the top row represents keyboard numbers. Use
Page Up (Iris Close), Page Down (Iris Open), Page
Left (Auxiliary On) and Page Right (Auxiliary Off) to display additional cameras and keyboards.
To change the partitioning setting for a keyboard and camera control:
1. Move the cursor to the crosspoint of the keyboard column and camera row that you want to partition.
2. Press Enter (Shot) to change the setting.
• Y (yes) indicates that a keyboard can control a specific camera.
• N (no) indicates that a keyboard cannot control a specific camera. This setting allows for viewing only.
• By default, all keyboards can control all cameras.
3. Repeat steps 1 and 2 for each keyboard/camera you want to change. Press Exit (Pattern) to return to the previous menu.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
38 of 43
8200-0170-05, REV. A
Partitioning Monitors and
Cameras
Use Monitors/Cameras to specify which monitors can view specific cameras.
CAM 01
0001 Y
0002 Y
0003 Y
0004 Y
0005 Y
0006 Y
0007 Y
0008 Y
0009 Y
0010 Y
0011 Y
0012 Y
0013 Y
0014 Y
0015 Y
0016 Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
02
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
04
Y
Y
Y
MONI TOR / CAMERA
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
03
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
05
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
06
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
07 08
Y Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
The left hand column represents camera numbers; the top row represents monitor numbers. Use Page Up
(Iris Close), Page Down (Iris Open), Page Left
(Auxiliary On) and Page Right (Auxiliary Off) to display additional monitor and camera numbers.
To change the partitioning setting for a monitor and camera:
1. Move the cursor to the crosspoint of the monitor column and camera row that you want to configure.
2. Press Enter (Shot) to change the setting.
• Y (yes) indicates that a monitor can view a specific camera.
• N (no) indicates that a monitor cannot view a specific camera.
• By default, all monitors can view all cameras.
3. Repeat steps 1 and 2 for each monitor/camera you want to change. Press Exit (Pattern) to return to the previous menu.
Configuring Alarms
Use the Alarms menus to configure alarm messages; configure RS-232, dome, and video loss alarms; and associate alarms to monitors.
ALARMS
1 ALARM MESSAGES
2 ALARM SETUP
3 ASSOCI ATE ALARMS TO MONI TORS
Configuring Alarm Messages
Use Alarm Messages to create messages to display whenever alarms are active.
ALARM MESSAGE
MESSAGE NUMBER - 1 - 250
ABCDEFGHI JKLMN cdef ghi j kl mnop qr st uvwxyz 012
3456789 <>: - . / ;
MESSAGE -
- - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - -
A maximum of 250 alarm messages can be entered through this menu. Each message may contain two lines of 24 characters (48 total characters). By associating the message with alarm contacts by using the four alarm setup menus, the message displays whenever the alarm contact is activated or sent to a paging device. The alarm message remains on screen until the alarm is cleared.
To program alarm messages:
1. Move the cursor to the message number line.
2. Enter the message number (1-250) and press
Enter (Shot).
3. Enter the alarm message: a. Press Next to move the cursor to the correct position in the message. b. Use the joystick to select the appropriate character from the display of letters, numbers and symbols. Press Enter (Shot) to select the correct character. c. Repeat steps 3a and 3b until the message is complete.
4. Press Exit (Pattern) to return to the previous menu.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
39 of 43
8200-0170-05, REV. A
Setting Up Alarms
Use Alarm Setup to configure specific alarm types.
ALARM SETUP
1 PATCH PANEL ALARM SETUP
2 RS- 232 ALARM SETUP
3 DOME ALARM SETUP
4 VI DEO LOSS ALARM SETUP
MP48 supports four alarm types:
• Patch Panel Alarms: Alarm contacts wired directly to the Alarms section of the patch panel.
16 patch panel alarm inputs are available.
• RS-232 Alarms: Alarm contacts routed to an
RS-232 port on the patch panel via an AD2096A
Alarm Interface Unit. 512 RS-232 alarm inputs are available.
• Dome Alarms: Alarm contacts routed from AD domes to the RS-422 or SensorNet connectors on the MegaPower 48 patch panel. Up to 192 dome alarm inputs (48 domes x 4 contacts) are available.
• Video Loss Alarms: Alarms triggered by the loss of the sync signal for any video input connected to the MegaPower 48 patch panel.
48 video loss alarm inputs are available.
Note: If video loss detection is enabled for any video input, video output 16 will not be available for video switching.
Once the specific alarm type is selected, individual alarm contacts can be associated with alarm messages, video inputs, alarm monitors, and paging numbers for text message transmission. Each monitor can be armed for unique alarm display and clearance methods. The following illustrates the
Patch Panel Setup menu; however, RS-232, Dome, and Video Loss setup menus include the same settings.
ALARM
VI DEO SELECT
PATTERN NUM
PRESET NUM
AUXI LI ARY
NUMBER
STATE
ALARM MSG
PAGI NG
SEND TO
MESSAGE
SYSTEM OUTPUT
NUMBER
LI NK
0
–
—
–
–
PATCH PANEL SETUP
0001 0002 0003 0004
0048 0034 0035 0031
02 02 02 02
–
00
–
00
–
00
–
00
0
–
—
–
–
0
–
—
–
–
0
–
—
–
–
0
N
0
N
0
N
0
N
The following settings are available:
Setting Description/Options
Alarm Alarm contact being configured.
Use Page Left (Auxiliary On) and
Page Right (Auxiliary Off) to display the contact numbers.
Video Select Video displayed when the alarm contact is activated. The number may represent a real camera number, pseudo camera number, or salvo.
Dwell (Sec) Time in seconds (1-61) the alarm will be displayed on screen during sequence queuing mode.
Pattern Num The pattern (1-3) displayed in response to the alarm contact. If this field is left blank, no pattern is displayed.
Note: If a pattern is used, the preset number must be left blank.
Preset Num The preset (1-96) displayed in response to the alarm contact. If this field is left blank, no preset is displayed.
Note: If a preset is used, the pattern number must be left blank.
Auxiliary
Number
One of the dome outputs that is activated or deactivated in response to the alarm contact.
Note: Leave this setting blank if you do not want an auxiliary action.
Auxiliary
State
The On or Off state of the selected auxiliary.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
40 of 43
8200-0170-05, REV. A
Setting Description/Options
Alarm Msg The alarm message that displays on a monitor in response to the alarm contact.
Note: Only monitors 1-8 can display alarm messages.
Paging
Send To
Paging
Message
System
Output
Number
The paging profile (1-64) that will be notified in response to an alarm.
The alarm message that is sent to the paging device.
Link
Two direct wired relays that can be either normally open or normally closed. Either of these system outputs can be energized for an alarm contact.
The link field provides the user with the option of linking the video associated with consecutive alarm contacts to form link salvos. Five types of links are available.
N (No): The next consecutive alarm contact entry is either not linked to the previous entry, or is the last entry in a link salvo.
Y (Yes): The next consecutive alarm contact entry is part of a link salvo.
S (Salvo): The alarm contact entry calls a system salvo. The system salvo number is specified in the video select field. Salvo may also be the last entry of a link salvo.
W (Wired): The alarm contact entry is a member of a wired set.
This means that if any member of the set is activated, all members of the set become activated. By programming a wired set, the user is eliminating the need to physically wire a group of alarm contacts together. Each alarm contact entry in a wired set is handled as a separate, active alarm armed to a monitor. The last entry of a wired set can be “N” or
“S”.
Wired Group Acknowledge (N*,
Y*, S*, W*): The alarm contact entry is a member of a wired set.
When the alarm is manually acknowledged, all members of the wired set will be cleared.
To setup alarms:
1. Select the alarm type (patch panel, RS-232, dome, or video loss) from the Alarm Setup menu.
2. Locate the alarm contact (top row) that you want to configure.
3. Enter the Video Selection. a. Position the cursor at the cross point of the
Alarm column and the Video Select row. b. Enter the camera or salvo number and press
Enter (Shot).
4. Enter the Dwell Time. a. Position the cursor at the cross point of the
Alarm column and the Dwell row. b. Enter dwell time between 1 and 61 (“61” = a
“hold” state) and press Enter (Shot).
Note concerning steps 5 and 6: The Pattern and
Preset settings cannot be used together. Choose either a pattern or preset, or leave the fields blank for no preset or pattern.
5. If a Pattern will be used, do the following: a. Position the cursor at the cross point of the
Alarm column and the Pattern row. b. Enter the pattern number (1-3) and press
Enter (Shot).
6. If a Preset will be used, do the following: a. Position the cursor at the cross point of the
Alarm column and the Preset row. b. Enter the preset number (1-96) and press
Enter (Shot).
7. Configure the Auxiliary setting. a. Position the cursor at the cross point of the
Alarm column and Auxiliary number row. b. Press Enter (Shot) to cycle through the auxiliary states: 1-4 On, 1-3 Off, and
0 (disabled). c. Press Next when the correct auxiliary state is displayed.
8. Enter the Alarm Message number. a. Position the cursor at the cross point of the
Alarm column and Alarm Msg row. b. Enter the alarm message number (1-250), and press Enter (Shot).
9. Enter the Paging information. a. Position the cursor at the cross point of the
Alarm column and Send To row. b. Enter a paging profile number (1 to 64), and press Enter (Shot).
The cursor moves to the Message field. c. Enter the alarm message number (1 to 250), and press Enter (Shot).
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
41 of 43
8200-0170-05, REV. A
10. Configure the System Output. a. Position the cursor at the cross point of the
Alarm column and System Output Number row. b. Press Enter (Shot) to cycle through the possible selections: 1 (energized), 2
(energized), or 0 (no relay selected). c. When the correct system output state is displayed, press Next to advance to the next field.
11. Configure the Link setting. a. Position the cursor at the cross point of the
Alarm column and Link row. b. Press Enter (Shot) to cycle through the choices:
Setting Description
N No. Does not link to the next consecutive alarm contact.
Y
S
Yes. Links to the next consecutive alarm contact.
Salvo. Displays the system salvo indicated in the Video Selection field in response to an alarm contact.
W
N *
Y *
S *
W *
Wired Set. Set of alarm contacts configured such that if any member of the set is activated, all members of the set will be activated.
Wired Group Acknowledge.
Indicates the alarm contact entry is a member of a wired set. When the alarm is manually acknowledged, all members of the wired set will be cleared. c. When the appropriate choice is displayed, press Next to advance to the next field.
12. When finished making changes, press Exit
(Pattern) to return to the previous menu.
Associating Alarms to Monitors
Use Associate Alarms to Monitors to configure specific alarm types to display on specific monitors.
ASSOCI ATE ALARMS TO MONI TORS
1 ASSOCI ATE PATCH PANEL ALARMS
2 ASSOCI ATE RS- 232 ALARMS
3 ASSOCI ATE DOME ALARMS
4 ASSOCI ATE VI DEO LOSS ALARMS
Each of the four alarm types (patch panel, RS-232, dome, and video loss) can have up to 10 monitor/alarm tables that can be programmed for different associations appropriate for different times of day. These tables are linked to times through the
Switching/Event Timers menu.
Once an alarm type is selected for configuration, a screen similar to the following is displayed.
ASSOCI ATE PATCH PANEL
ALARM 01
0001 N
0002 N
0003
0004
0005
0006
0007
0008
0009
0010
0011
0012
0013
0014
0015
0016
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
02
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
03
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
04
N
N
TABLE —
MONI TOR
Use Page Up, Page Down, Page Right and Page
Left to display the monitors and alarm contact numbers.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
42 of 43
8200-0170-05, REV. A
To configure an alarm contact table:
1. Move the cursor to the Table position. Enter the alarm contact table number (1-10) if the table will be used with event timers.
Note: If the default table is to be used, do not enter table number.
2. Associate alarms to monitors. a. Position the cursor at the cross point of the
Monitor column and Alarm row. b. Press Enter (Shot) to toggle the setting.
N No association between the alarm contact and monitor.
Y Alarm association between the alarm contact and monitor. c. When the correct auxiliary state is displayed in the number and state rows, press Next. d. Repeat steps 2a-2c for each association you want to make.
3. When finished making changes, press Exit
(Pattern) to return to the previous menu.
Declarations
Thank you for using American Dynamics products. We support our products through an extensive and worldwide network of dealers. The dealer, through whom you originally purchased this product, is your point of contact if you have a need for service or support. Our dealers are fully empowered to provide the very best in customer service and support. Dealers should contact American Dynamics at (800) 507-6268 or
(561) 912-6259 or on the web at www.americandynamics.net.
WARRANTY DISCLAIMER: Sensormatic Electronics
Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose.
NOTICE: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change without notice.
LIMITED RIGHTS NOTICE: For units of the Department of
Defense, all documentation and manuals were developed at private expense and no part of it was developed using
Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: American Dynamics and
Sensormatic are trademarks or registered trademarks of
Sensormatic Electronics Corporation. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies.
COPYRIGHT: Under copyright laws, the contents of this manual may not be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of
Sensormatic Electronics.
BSL 07/2004
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
43 of 43
8200-0170-05, REV. A
Download
Advertisement
Key features
- Compatible with MegaPower 48 matrix switcher/controller systems
- Provides Keyboard Lock, Program, and Menu modes
- Intuitive LCD display for easy operation
- Tracker ball for precise camera control
- Zoom and focus buttons for detailed viewing
- Auxiliary control for gates, doors, lights, and other devices
- Alarm acknowledgment for quick response to security events
Frequently asked questions
The ADTTE keyboard has three operating modes: Keyboard Lock, Program, and Menu.
The tracker ball is used for precise camera control, allowing you to pan, tilt, and zoom in on specific areas of interest.
Yes, the ADTTE keyboard provides auxiliary control for gates, doors, lights, and other devices.