INSTALLATION INSTRUCTIONS
Angled Bath Shower Mixer
(Excluding handles, unions and bases) -
T9
DECK-MOUNTING
* The package in this product has no handles,
deck mounting unions or bases supplied.
The handles & unions shown in the diagram are for reference only.
Option 1:
Burlington has 4 different style handle for your selection.
WALL-MOUNTING
* The package in this product has no handles,
wall mounting unions or bases supplied.
The handles & unions shown in the diagram are for reference only.
Option 2:
Burlington also have a base (27mm height) for your selection.
Claremont Anglesey Birkenhead Kensington
NOT INCLUDED IN THE ANGLED BATH SHOWER MIXER BOX
Important
● We recommend that this product is installed by a qualified professional contractor. Such as a plumber who is certified by NVQ
(National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3
● Please check this product immediately to ensure that it has not been damaged and is complete. Before installation, please make
sure this product is the correct model and you have all the parts required for installation and using.
● All the taps in Burlington Range should be supplied with hot and cold water at balanced pressure. If not, then the mixing function
will not work correctly. It is necessary to fit non-return valves on both hot and cold feeds pipe. These are not supplied.
● Please flush the water system to ensure that no metal swarf, solder, and other impurities can enter the taps.
● Turn off water supply before commencing work, this should be done at the isolating valves of inlet feeds if fitted or main stopcock.
● Please read these instructions carefully and keep it for future reference.
Working pressure
The tap is suitable for both high and low pressure installation. To ensure that the tap works well under low water pressure, the cold water storage tank must be at least 2 meters above the installed position. The maximum water pressure is 6 bar. Where the water pressure above 6 bar, then a pressure reducing valve must be fitted.
1 - 4 D
Dimension
236
180
R
SHO
WE
BAT
H
130
Burlington
London
Diameter:Ø16
Extent:1500mm
DECK-MOUNTING
Installation
HOT
CONTROL
HANDLE
JOINT NUT
DECK
MOUNTING
UNION
“O” RING
55
SHOWER
OUTLET
G3/4
60 ~ 300
G3/4 130
157
SPOUT/SHOWER
DIVERTER HANDLE
COLD
CONTROL
HANDLE
HANDLE
FLAT WASHER
SPRING WASHER
SCREW
DECORATIVE
CAP
WASHER
SPOUT
DECK MOUNTING
UNION
NOT INCLUDED IN THE MIXER BOX
Note: To ensure the Kensington lever tap head faces in the
correct forward position once installed, you may need
to tighten the cartridge into the tap body a notch with
a monkey spanner and then re-attach the tap head.
Bath
Worksurface
RUBBER
WASHER
FIXING
NUT
NOT INCLUDED IN THE MIXER BOX
If identify to install the Angled Bath Shower Mixer on the Bath, you need install the T18 (Deck mounting unions) on the bath first.
A) Remove the washers and fixing nuts from the tails of Deck mounting unions.
B) Insert the tails in two tap holes on bath.
C) Tighten the rubber washer & the fixing nut from the under-side of the bath, and make sure the two unions at 180mm centers.
D) Tighten the Bath Shower Mixer on joint nut and connect to the Deck mounting unions.
2 - 4 D
Dimension
236
180
ER
SHOW
BAT
H
130
Burlington
London
Diameter: Ø16
Extent:1500mm
WALL-MOUNTING
48
180
157
130 124.5
Installation
HANDLE
FLAT WASHER
SPRING WASHER
SCREW
DECORATIVE
CAP
NOT INCLUDED IN THE MIXER BOX
Note: To ensure the Kensington lever tap head faces in the
correct forward position once installed, you may need
to tighten the cartridge into the tap body a notch with
a monkey spanner and then re-attach the tap head.
JOINT NUT
NOT INCLUDED IN THE MIXER BOX
SHOWER
OUTLET
SPOUT/SHOWER
DIVERTER HANDLE
HOT
CONTROL
HANDLE
COLD
CONTROL
HANDLE
WASHER
SPOUT
180mm
Wall
WALL MOUNTING
UNION
Ø28mm
Hole
“O” RING
WALL MOUNTING
UNION
If identify to install the Angled Bath Shower Mixer on the wall, you need install the T17-2 (Wall mounting unions) on the wall first.
A) On the wall Drill at 2 X 28mm diameter holes at 180mm centers.
B) Unscrew the tails from the unions elbow part.
C) Smear or wind a suitable sealing material round the tail and then insert the tails into the holes on the wall. The fibre washer (not supplied)
may be inserted between the tail and the wall or tile surface to protect it.
D) Connect the water supplier pipes to both tails. From a front view, hot water on the left and cold water on the right.
E) Tighten the elbow part back with tails again. And make sure the outlets are upward and at 180mm centers.
F) It is possible to use a G3/4 fixing nut(not supplied) to secure the wall mounting unions if they reach through a wall and the supply can then
terminate in a swivel or flexible coupling.
G) Tighten the Bath Shower Mixer on joint nut and connect to the Wall mounting unions.
3 - 4 D
Shower Handset
Holder - Option 1
CRADLE
Shower Handset
Holder - Option 2
CRADLE
Install the shower handset holder
A) Insert a washer into the end nut of
handset holder, and tight the holder
on the Angled Bath Shower Mixer Body.
B) If you don’t need the “S adjustor”,
please take off it by using the Allen
key to unscrew two grub screws
on the holder.
GRUB
SCREW
B)
“ S ”
ADJUSTOR
GRUB
SCREW
HANDSET
HOLDER
A)
Shower Handset Connections
SHOWER HANDSET
WASHER
HOSE
Install the shower handset and hose
A) Insert a PCW water regulator into the nut end of
hose and tight it to the mixer outlet.
B) Insert a washer into the cone end of hose
and tight it with shower handset.
C) Please remove the PCW water regulator and
replace with supplied washer if you feel the
water flow from handset is too low.
HOSE
The water flow hits the black O-ring first.
O ring
PCW WATER
REGULATOR
GRUB
SCREW
HANDSET
HOLDER
Straightener and aerator (alternative options)
The tap comes with a factory-fitted flow straightener for low pressure water systems.
If the water flow is high, replace the factory-fitted flow straightener with the high pressure aerator supplied.
Use NEOPERL Key to unscrew the straightener in the Nozzle. Replace with the aerator provided, and screw back in nozzle tightly. (If you misplace the Neoperl key you can use the top of the aerator/straightener as a key)
FLOW STRAIGHTENER AERATOR
Cleaning
Before use: Unscrew the filter and allow the water to run freely for
5 minutes. Then screw the filter back in place.
NOZZLE
Periodically: Using the key provided unscrew the nozzle and remove.
Rinse it with cleaning running water until any loose debris is cleared.
Then replace the nozzle and tighten with key provided.
KEY
Maintenance
We do NOT recommend you use any household cleaners to clean the product. Because these cleaners change substance or formula too frequently. The product should be always cleaned only with soapy water and rinsed with clean water and dried with a soft cloth.
4 - 4 D
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project