Advertisement
Advertisement
Operating Instructions Digital Video Recorder Models: DTR-2009/250CD, DTR-2016/250CD, DTR-2009/500CD, DTR-2016/500CD, DTR-2009/750CD DTR-2016/750CD Safety instructions EMC class ► This digital video recorder (DVR) is a class A device in accordance with EN 55022. ► This device may cause interference to other equipment in domestic use. In such cases the persons operating the DVR are required to provide appropriate countermeasures, for which they themselves bear the cost. Importance of these Operating Instructions ► Please read the safety instructions and the other information contained in the Operating Instructions before connecting up and operating the DVR. ► The Operating Instructions should be kept in a safe place for later reference. Ambient conditions ► The DVR should be protected against excessive heat, dust, moisture and vibration. ► The DVR may only be operated at temperatures between +5°C and +40°C, and up to a maximum air humidity of 90%. ► The DVR may only be operated indoors, and must be protected against ingress of water and moisture. Care of the DVR ► Never switch on the DVR when moisture has penetrated it. In such cases, have the DVR checked by a qualified service engineer. ► Do not place any heavy objects on the DVR. ► Never cover over the DVR‘s vents. ► Never insert metal objects or any other items into the vents. This may permanently damage the DVR. ► The housing may only be opened by authorised persons. Repairs may only be carried out by qualified service personnel. ► The DVR must be disconnected from the power supply before its housing is opened. Getting started with the DVR ► When laying the connecting cables, make sure no weight is placed on them, that they are not kinked or damaged, and that no moisture can penetrate them.. Cleaning ► The housing of the DVR may only be cleaned with a moisture (not wet) cloth. ► Use only a mild detergent. Do not use solvent-containing detergents or petrol. This could permanently damage the surface finish. Spare parts ► Use only original spare parts from Videor Technical GmbH.. DTR-20XX Table of contents Overview Package contents Basis functions Features Requirements for operation Control options Connections on the rear Front panel controls Key to controls Function buttons PTZ camera functions Playback functions Remote control functions Playback functions Menu overview Accessing the menus Accessing the Display menu Accessing the PTZ menu Accessing the Setup menu Accessing the Search menu Getting started Checklist for DVR operation Connecting the remote control and DVR Switching on the DVR Switching off the DVR Administration Saving your system setup Loading your system setup Deleting recordings Downloading software updates Hiding from specific users Restoring factory defaults Determining the memory requirement of a recording Searching for recordings Using calendar search Using event log search Using text-in search Using motion search Copying recordings DTR-20XX 7 7 7 7 7 7 8 9 10 10 10 10 11 11 12 14 14 14 15 15 16 16 16 17 17 18 18 18 18 19 19 19 20 21 22 23 24 25 26 Table of contents Menu descriptions – Setup menu 27 System – Information 28 System – Date/Time 29 System – Storage30 System – User32 System – Shutdown33 System – Log out user1...33 Network – Network33 Network – Notification 36 Devices – Camera37 Devices – Audio38 Devices – Alarm-Out39 Devices – Display 40 Devices – Remote Control 41 Record – Record 42 Record – Schedule 43 Record – Pre-Event 44 Record – Archive 45 Event – Alarm-In 46 Event – Motion Detection 48 Event – Video Loss 50 Event – Text-In 52 Event – System Event 54 Event – Event Status 56 Specifications DTR-2009 57 Specifications DTR-2016 59 Accessories 61 Supported PTZ cameras 62 Index 63 Notes on disposal 66 DTR-20XX Overview Package contents ● ● ● ● ● ● ● ● ● Digital video recorder (DVR) Mains power cord Operating instructions RAS (Remote Administration System) software on CD Operating instructions for RAS software on paper and CD Mounting kit for rack installation Screws for attaching SCSI Connector Mounting screws and guide for installation of hard disk drives Infrared remote control Basis functions ● ● ● ● Recording of video images from multiple cameras Event-triggered start of recording Video playback Search for specific video sequences Features ● ● ● ● ● ● ● ● ● ● ● ● MPEG-4 compression / duplex mode 9 or 16 loop-through inputs / VGA, S-VHS/FBAS outputs Audio and alarm inputs / outputs Max. recording speed: 100 field images per sec (PAL) Memory capacity 250 GB / 500 GB / 750 GB Maximum video resolution 720 x 576 pixels SCSI port for archiving / memory expansion Various recording criteria possible Archiving/image transfer via USB and CD-RW ATM/POS text display / 2x to 4x digital zoom Telemetry control functions via RS-485 port Network port (Ethernet) / IR remote control Requirements for operation ● ● ● ● Digital video recorder DTR connected At least 1 camera connected At least 1 monitor connected Mouse connected, if DVR is to be controlled by mouse Control options ● ● ● ● Front panel Remote control Mouse RAS program DTR-20XX Connections on the rear Note: Connections optionally for NTSC or PAL operation. 1 2 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 VIDEO OUT SPOT 1 SPOT 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SVHS OUT SPOT 3 SPOT 4 VIDEO IN LOOP AUDIO IN 1 AUDIO IN 2 AUDIO IN 3 AUDIO IN 4 AUDIO OIT AI1 AI2 AI3 AI4 GND AI5 AI6 AI7 AI8 GND AI9 AI10 AI11 AI12 GND AI13 AI14 AI15 AI16 GND AO1 AO2 AO3 AO4 GND AO5 AO6 AO7 AO8 GND AO9 AO10 AO11 AO12 GND AO13 AO14 AO15 AO16 GND ARI GND RS-485 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN 18 17 USB 16 15 14 1 RS-232C 12 VGA 11 SCSI 10 9 NETWORK 8 No. Designation Functions/connections Example devices 1 VIDEO IN 1-16 Max. 16 video channels Cameras 2 LOOP 1-16 Max. 16 loop-through video channels Cameras 3 SVHS OUT S-VHS output Monitors 4 VIDEO OUT Video output Monitors 5 SPOT1 - SPOT4 Max. 4 video outputs Spot monitors 6 RS-485 External interface Keyboard, PTZ camera 7 NETWORK Network Network cable 8 ARI/GND Reset alarm with external signal Switch 9 SCSI External storage media Hard disk 10 AO1 - AO16 Alarm outputs for external devices Siren, flashing light 11 VGA PC monitor PC monitor 12 RS-232C External interface Modem 13 USB External interface Drive, mouse 14 Reset switch Reset to factory defaults - 15 AI1 - AI16 Alarm inputs for external devices Sensors 16 AUDIO OUT Audio output Amplifier, speakers 17 AUDIO IN 1 AUDIO IN 4 Max. 4 Audio inputs Microphone 18 Power supply Mains power connection - 7 DTR-20XX Front panel controls The following diagram and table shows the controls on the front panel of the DVR: 1 2 1 4 2 3 4 5 5 6 7 6 8 PANIC JOG CAMERA 9 10 11 12 DISPLAY SEQUENCE FREEZE SPOT MENU ALARM ZOOM PTZ 13 14 15 SEARCH PLAY/PAUSE RW FF BACKWARD FORWARD 16 HDD NETWORK 14 No. Designation 1 12 POWER 11 10 9 8 7 Function 1 USB ports 2 Eject built-in CD-RW writer 3 1 to 16 ● Select cameras ● Enter passwords 4 Menu navigation Navigation and selection within the menu 5 PANIC Start/end panic recording 6 Shuttle ring Infinitely adjust playback speed 7 Jog dial ● Change size of frame in picture-in-picture mode ● Change numerical values in Setup menu ● Frame-by-frame playback in Play mode Playback functions (primary assignment) 8 PTZ camera functions (secondary assignment) 9 POWER Power-on indicator when DVR is in operation 10 NETWORK Indicates Ethernet or modem connection 11 HDD Indicates hard disk operation 12 DISPLAY, SEQUENCE, FREEZE, SPOT, ZOOM, PTZ Function buttons 13 ALARM ● Reset alarm ● View event list 14 MENU Open/quit menu structure DTR-20XX Key to controls Function buttons Element Function ● Change display mode ● Switch video input by pressing and holding down button Sequence On/Off Freeze On/Off PTZ camera functions On/Off Zoom On/Off Spot monitor assignments PTZ camera functions Element Function Zoom in Zoom out Close-up Wide-angle Save preset Load preset Playback functions Element Function ● Select Search/Play function ● Stop playback Frame-by-frame rewind Fast rewind Start/pause playback Fast forward Frame-by-frame forward 10 DTR-20XX Remote control functions The following diagram and table shows the functions on the remote control: Select System ID ID SPOT 1 2 DISPLAY SEQUENCE 12 11 3 4 FREEZE ALARM CAMERA 1 2 3 5 6 7 8 9 10 11 12 15 16 13 14 TRIPLEX AUDIO 4 FOCUS 2 BOOK MARK CLIP COPY 4 SET 10 1 PRESET ZOOM VIEW MENU 9 PTZ 5 ZOOM PANIC 6 8 DIGITAL VIDEO RECORDER Remote Controller 7 No. Designation Function 1 SPOT 1 - 4 Spot monitor assignments 2 ALARM ● Reset alarm ● View event list 3 1 to 16 ● Select cameras ● Enter passwords 4 PTZ camera functions 5 PTZ PTZ camera functions On/Off 6 ZOOM Zoom On/Off 7 Playback functions 8 PANIC Start/end panic recording 9 Menu navigation Navigation and selection within the menu 10 MENU Open/quit menu structure 11 12 No function DISPLAY, SEQUENCE, FREEZE Function buttons Playback functions Element Function ● Select Search/Play function ● Stop playback Pause playback Start playback Fast rewind Fast forward Frame-by-frame rewind Frame-by-frame forward DTR-20XX 11 Menu overview The following illustration shows the structure of the complete menu tree that is accessible using the mouse control: Display Camera 1. CAM1 2. CAM2 3. CAM3 PIP Left-Top Left-Bottom Right-Top Right-Bottom Size 1/16 Size 1/9 Size 1/4 2x2 3x3 4x4 Previous Group Next Group Edit Group Sequence Freeze Zoom... PTZ... Spot Monitor... Toggle VGA ... 12 Camera Spot Monitor... Toggle VGA ... Exit Group Edit Speed Auto Pan Tour Pattern Device Menu Light Pump Wiper Power Aux. Move to Origin Spot Monitor Toggle VGA ... Exit PTZ Select Spot Monitor Spot Monitor 1 Spot Monitor 2 Spot Monitor 3 Spot Monitor 4 DTR-20XX Menu overview, continued The following illustration shows the structure of the complete menu tree that is accessible using the mouse control: Setup menu... Search System Information Date/Time Storage User Shutdown... Log out user1... Network Network Notification Devices Camera Audio Alarm-Out Display Remote Control Record Record Schedule Pre-Event Archive Event Alarm-In Motion Detection Video Loss Text-In System Event Event Status Go to the First Go to the Last Go to the Date/Time... Calendar Search... Event Log Search... Text-In Search…. Motion Search... Clip-Copy... Print... Zoom... Slow Play Data Source Exit Search DTR-20XX x1 x1/2 x1/3 x1/4 x1/6 x1/8 Record Archive 13 Accessing the menus Accessing the Display menu Requirement: ● The current camera image is shown in full image or quad image. Step Action Access using Key sequence/menu path Device 1 Open Display menu... Remote control Mouse Display Access to submenu via Device/Remote Control Submenu Camera image Key sequence Change Display modes (PIP, 2x2, 3x3, 4x4) Without frame Previous/Next Group Without frame Edit Group With frames Change position of image-in-image Without frame Change size of image-in-image Without frame Jog dial Action Access using Key sequence/menu path Open PTZ menu... Device Result: Menu of the configured PTZ camera is shown. Remote control PTZ Mouse PTZ... .... > Accessing the PTZ menu Requirement: ● A PTZ camera is connected and configured. ● Current camera image is shown as a full image. Step 1 14 > > MENU DTR-20XX Accessing the menus, continued Accessing the Setup menu Requirement: ● The current camera image is shown in full image or quad image. Step 1 2 Action Access using Open Setup menu... Device Key sequence/menu path Result: Prompt for user name and password. Remote control MENU Mouse Setup menu... Log in as user. User name: admin Password: (blank) Note: Use default access data only for first-time access. Accessing the Search menu Requirement: ● The current camera image is shown in full image or quad image. Step 1 DTR-20XX Action Access using Key sequence/menu path Open Search menu... Device > Result: Search for recorded images is activated. Remote control > Mouse MENU Search 15 Getting started Checklist for DVR operation Step Action Menu path 1 Connect peripheral devices as per planned setup. 2 Specify menu language.. Setup menu... > System > Information 3 Adjust date and time.. Setup menu... > System > Date/Time 4 Set up user. Setup menu... > System > User 5 Set up network and desired notification channels (optional). Setup menu... > Network > ... 6 Register peripherals with DVR. Setup menu... > Devices > ... 7 Set up event types and associated responses. Setup menu... > Event > ... 8 Set up recording parameters and schedule. Setup menu... > Record > ... Connecting the remote control and DVR The remote control and DVR can be assigned an ID, because the ID of each DVR in the network must be unique. The DVR will then only respond to the remote control with the matching ID. ● If the system ID in the DVR is 0, it will respond to the remote control regardless of the remote’s ID. ● If the system ID in the DVR is not 0, you must set the ID of the remote control identically. Step Action Menu path 1 Set DVR system ID. Setup menu... > System > Information 2 Match remote control to system ID by pressing ID button on remote control. 3 Select relevant number on remote control. 16 DTR-20XX Getting started, continued Switching on the DVR Requirement: ● The start-up preparations are complete. Step Action 1 Plug in DVR mains plug. 2 Switch on monitor. Result: System starts up automatically and is ready to use. Switching off the DVR Requirement: ● You have accessed the Setup menu. Step 1 2 DTR-20XX Action Shut down system. Result: System shuts down automatically. Menu path Setup menu > System > Shutdown ... After shutdown, disconnect the mains plug. 17 Administration Saving your system setup You can save your DVR’s setup data, including its network configuration. Requirement: ● USB memory stick Step Action 1 Insert a USB memory stick into one of the USB ports 2 Export your setup. 3 Specify a file name. 4 Export your setup. Menu path Setup menu... > System > Information > Setup Export... Export Loading your system setup You can load your stored DVR system setup with or without its network configuration. Requirement: ● USB memory stick with stored setup Step Action Menu path 1 Insert a USB memory stick into one of the USB ports. 2 Import your setup. 3 Select the file name and, where appropriate, the network configuration. 4 Import your setup. Setup menu... > System > Information > Setup Import... Import Deleting recordings You can only delete all your recordings together. It is not possible to delete recordings from a specific time period. Step 1 18 Action Menu path Delete all recordings. Setup menu > System > Information > Clear All Data... or Setup menu > System > Storage > Information tab > Using > Clear DTR-20XX Administration, continued Downloading software updates You can download software updates for your DVR from a USB memory stick. Requirement: ● USB memory stick with latest software release Step Action 1 Insert a USB memory stick into one of the USB ports. 2 Start update. 3 Install new release Menu path Setup menu... > System > Information > Upgrade... Hiding from specific users You can hide video images and camera data according to the preset user rights. Step Action Menu path 1 Set camera Covert mode. Setup menu... > Devices > Camera > Settings 2 Cancel ‘Covert Camera View‘ access for specific users (groups). Setup menu... > System > User Restoring factory defaults Before restoring the factory defaults, you should export your current system settings in case you need to reimport them later. (see Saving your system setup and Loading your system setup) Step Action 1 Shut down the system. 2 Disconnect the mains plug. 3 Push a paper clip into the Reset button (on the rear of the DVR) and hold it there. 4 Plug in the mains plug. 5 Wait for all the LEDs to flash 5 times (about 30 seconds). 6 Withdraw the paper clip. DTR-20XX 19 Administration, continued Determining the memory requirement of a recording The amount of memory recorded video sequences will take up depends on the following factors: ● picture quality ● number of images per second ● duration The memory requirement is calculated by this formula: Memory requirement = picture size x duration of recording x images per second Example calculation of CIF resolution (PAL): Approx. memory space Picture quality Picture size Duration of recording 5 images/s 10 images/s 25 images/s Basic 2.4 KB 24 hours 1.04 GB 2.07 GB 5.18 GB Standard 4.8 KB 24 hours 2.07 GB 4.15 GB 10.37 GB High 9.6 KB 24 hours 4.15 GB 8.29 GB 20.74 GB Very high 14.4 KB 24 hours 6.22 GB 12.44 GB 31.10 GB Example calculation of 2CIF resolution (PAL): Approx. memory space Picture quality Picture size Duration of recording 5 images/s 10 images/s Basic 4.8 KB 24 hours 2.07 GB 4.15 GB 10.37 GB Standard 9.6 KB 24 hours 4.15 GB 8.29 GB 20.74 GB High 19.2 KB 24 hours 8.29 GB 16.59 GB 41.47 GB Very high 28.8 KB 24 hours 12.44 GB 24.88 GB 62.20 GB 20 25 images/s DTR-20XX Searching for recordings Find first stored recording Search Go to the First Find last stored recording Search Go to the Last Find recording by date and time Search Go to the Date/Time... Calendar search For each camera the calendar search indicates: ● the days from which there are recordings ● the time ranges of recordings on those days Search Calendar Search... Event log search The event log search enables you to search for events based on specific criteria, such as: ● movements recorded by a specific camera ● alarm from a specific alarm input ● System events Search Event Log Search... Text-in search The text-in search enables you to search for recordings based on specific text inputs. Search Text-In Search… Motion search The motion search function can detect movements in recordings within defined zones for one camera. 2 types of motion search are possible: ● Motion search: Search for movement in a defined zone. ● Museum search: Search for movement of a defined object. Search Motion Search... Copying recordings Recordings can be written to a CD or copied to a USB memory stick. Search DTR-20XX Clip-Copy... 21 Using calendar search Performing a calendar search Step 1 Action Menu path Open calendar search. Result: Calendar and time line are displayed. 2 Select day and time 3 Confirm input. Search Term Search > Calendar Search... Go Calendar Search... Symbol Meaning Date display ● Grey: No recording available ● White: Recording available Hours display ● White: Recording available Select a Segment 22 If the date and time on the DVR have been changed (such as when switching to Summer time) there may be multiple recordings for one time from the same camera. They are stored in separate segments. DTR-20XX Using event log search Performing an event log search Step 1 2 3 4 Action Menu path Open event log search. Result: The result of the last search is displayed. Define criteria. Search > Event Log Search... Option... Confirm input. Result: List of search results is displayed. Search Select desired entry from list. Search Term Event Log Search... Symbol Option... Meaning From First Start date To Last End date Check Time Overlap Activates a system prompt if there are multiple recordings for the same time range Alarm-In Alarm inputs in response to which a search for events is to start Motion Cameras on which to search for motion detection Video Loss Cameras on which to search for video loss Text-In Text input devices on which to search for events Record Channels Cameras on which to search for events Search for system events: Setup menu > Event > System Event > Actions DTR-20XX 23 Using text-in search Performing a text-in search Step 1 2 3 4 Action Menu path Open text-in search. Result: The result of the last search is displayed. Define text inputs. Search > Text-In Search... Option... Confirm input. Result: List of search results is displayed. Search Select desired entry from list. Search Term Text-In Search… Symbol Option... Meaning From First Start date To Last End date Channels Text input devices on which to search for events Type of text input: Any Text-In Product Generic Text Epson No. Numbers of text elements to search for Keyword Text element Case Sensitive Makes search case-sensitive 24 DTR-20XX Using motion search Performing a motion search Step Action Menu path 1 Display desired camera in single frame. Display > Camera > ... 2 Open motion search. Search > Motion Search... 3 Enter settings for motion search. Option... 4 5 Search Term Confirm input. Search Result: List of search results is generated. Select desired entry from list. Motion Search... Symbol Option... Meaning From First Start date To Last End date Type of search: Type Zone Motion Search Search for movement in a defined zone Museum Search Search for movement of a defined object Definition of motion-sensitive zones for motion search or museum search: See “Zone” on page 46. Sensitivity of motion detection of: 1 (Dull) Sensitivity 2 3 4 5 (Sensitive) Min. Blocks DTR-20XX Motion search only (not museum search): Specify in how many motion-sensitive blocks motion must be detected as a minimum to trigger an alarm 25 Copying recordings Copying recordings to CD or USB memory stick Step 1 2 3 Search Term Data Source Action Menu path Find desired recordings. Note: Make a note of the data of the recordings you want to copy. Search > ... Define settings. Search > Clip-Copy... Start copying. Result: The recordings are copied. Start Clip-Copy... Symbol Meaning Record From First Start date To Last End date Channels Assignment of cameras from which recordings are to be copied Password Use password, if desired Destination medium: Internal CD-RW Dest. USB CD-RW 1. USB Storage 2. USB Storage 3. USB Storage File name Name of file on destination medium Verify After Burning Activates verification after burning Progress Copy status 26 DTR-20XX Menu descriptions – Setup menu The Setup menu has the following sub-menus: System menu On the “System” menu ● the basic settings are made ● users are administered ● the system is shut down Network menu On the “Network” menu the network settings are made. Network access provides access to all the functions of the DVR via ● RAS (Remote Administration System), independent of Internet Explorer The DVR can be configured so that alarms trigger a notification by e-mail or notify an RAS. Devices menu On the “Devices” menu the connected peripheral devices are configured. Possible peripherals are: ● Cameras ● Microphones and speakers (through amplifier) ● Sirens and signal lamps ● Monitors ● Remote control for PTZ Record menu On the “Record” menu the following settings are made: ● Recording quality ● Timer control ● Duration of pre-event recording ● Schedule and method of archiving Event menu On the “Event” menu the following settings are made: ● Assignment of alarm inputs to alarms ● Configuration of motion-sensitive zones individually for each camera ● Definition of text input device and assignment to alarms ● Response to undesirable events The event status is additionally displayed. DTR-20XX 27 Setup menu System – Information On the “Information” menu ● basic information is entered and displayed ● software updates are installed ● recorded data are deleted as required Setup menu... Term System Symbol Information Meaning Site Location of DVR System ID Identifier for remote control ● The remote control and DVR must be set to the same ID. ● If the system ID in the DVR is 0, it will respond to the remote control regardless of the remote’s ID. Language Menu language Version Version of DVR software Upgrade... Starts installing latest version of software via USB port Import... Import setup Export... Export setup Show System Log... Show log of all actions and events Recorded data From Date of oldest recording To Date of newest recording Clear All Data... Deletes all stored data 28 DTR-20XX Setup menu, continued System – Date/Time On the “Date/Time” menu ● time and date settings are made ● dates of public holidays are entered ● time synchronisation is configured. Setup menu... Term System Symbol Date/Time Date/Time Meaning Date Date Format Date display format Time Time Format Time display format Time Zone Local time zone Use Daylight Saving Time Activates use of summertime Daylight Saving Time Setup menu... Term System Symbol Date/Time Holiday Meaning No. Number of entered public holiday Date Date of each desired public holiday Setup menu... Term System Symbol Date/Time Time Sync Meaning Automatic Sync Activates synchronisation with time server Time Server IP address or domain name of time server Interval Synchronisation interval Last Sync-Time Time of last synchronisation Run as Server Activates use of the DVR as the time server DTR-20XX 29 Setup menu, continued System – Storage On the “Storage” menu the status and usage of the available storage media is displayed. Setup menu... Term System Symbol Storage Information Meaning Type Type of storage medium Capacity Size of storage medium Format Storage medium usage >> Information Time range of recorded data >> Format Term Symbol Meaning Use of storage medium: Record Use as Archive Not using Activating permits: Partition CD/DVD burn Format Reserves a data buffer as a separate partition. This is essential for burning CDs, and must be activated for a storage medium with „Record“ usage.. Formatting deletes the recordings from the hard disk Information Term Symbol Meaning Recorded data From Start date of recorded data To End date of recorded data Clear Delete all recordings 30 DTR-20XX Setup menu, continued Setup menu... Term System Symbol Storage Meaning Type Memory type Disk Bad Data carrier status Temperature Temperature status S.M.A.R.T. Result of S.M.A.R.T. check DTR-20XX Status 31 Setup menu, continued System – User On the “User” menu the user groups and individual users are set up. Setup menu... Term System Symbol User Meaning Group & User Group field Assignment of group access privileges Table of possible group access privileges >> Group & User User field Set password + Group... Add a new group + User... Add a new user Set password Auto Login User to be logged in automatically Auto Logout Time after which logged-in user is automatically logged out Table of possible group access privileges Group access privilege Meaning Shutdown May shut down the DVR Upgrade May install a new firmware version System Time Change May change the time setting Data Clear May delete recording data Setup May make changes anywhere on the Setup menu Color Control May change the picture settings PTZ Control May control PTZ cameras Alarm-Out Control May reset alarms Covert Camera View May view video images from covert cameras System Check May interrogate system status Record Setup May make changes to the Record menu Search May use Search mode Clip-Copy May copy video images 32 DTR-20XX Setup menu, continued System – Shutdown Setup menu... System Shutdown... System – Log out user1... Setup menu... System Log out user1... Network – Network On the “Network” menu all settings required to ensure network access are made. Setup menu... Term Network Symbol Network Network Meaning Transmission bandwidth: Transfer Speed (bps) bits per second (ips) images per second Quality of picture transmission via network (PAL): Quality DTR-20XX Very High 14.4 KB/picture High 9.6 KB/picture Standard 4.8 KB/picture Basic 2.4 KB/picture 33 Setup menu, continued Setup menu... Term Network Symbol Network LAN Meaning Type of connection to DVR: Type Manual Manual connection required input of: ● IP address ● Gateway ● Subnet Mask DHCP Automatic assignment of IP address of DNS server ADSL (with PPPoE) Requires following input as specified by provider: ● ID ● Password Note: Use of modem must not be activated. DNS Server Address of DNS server Port Number Setup... Definition of port numbers needed to access the DVR via the RAS software Setup menu... Term Enable Network Symbol Network Meaning Enables modem use Note: LAN type ADSL must not be enabled. Baud Rate Baud rate Data Number of data bits Stop Bit Number of stop bits Parity Parity 34 Modem DTR-20XX Setup menu, continued Setup menu... Term Network Network Symbol DVRNS Meaning Use DVR Name Service Enables the DVR name service DVRNS Server IP address or domain name of DVRNS server DVRNS = Digital Video Recorder Name Service Port Port for DVRNS Use NAT Enables NAT (Network Address Translation) use DVR Name Name by which the DVR is to be registered with the DVRNS server Check Check DVR name for usability after entering Help Desk Information from help desk if DVRNS setting correct DTR-20XX 35 Setup menu, continued Network – Notification On the “Notify” menu the method of notification is defined. Setup menu... Term Network Symbol Notification Mail Meaning Enable Enables notification by e-mail SMTP Server IP address or domain name of SMTP server Port Port for SMTP server Default is port 25. Authentication Login to SMTP server Sender E-mail address of sender Recipient E-mail address of recipient Setup menu... Term Network Symbol Notification Callback Meaning LAN Enables notification of an RAS via LAN No. Number of IP address IP Address IP addresses of RAS PCs Retry Number of notification attempts by the DVR in the event of an error Modem Enables notification of an RAS via modem Remote Server Phone Number Telephone number of the modem on the notified RAS PC Outside Line Call Outside line code for external calls, if DVR’s modem is connected to a PABX system Callback Phone Number Telephone number of DVR’s modem The RAS PC contacts the DVR on this number. 36 DTR-20XX Setup menu, continued Devices – Camera On the “Camera” menu the cameras are configured. Setup menu... Term Devices Symbol Camera Settings Meaning No. Activates the cameras Title Name of camera Visibility of recordings and camera data depending on user access privileges: Use Setup menu... Term Normal All users see all camera data and all recordings Covert 1 Users without relevant access see camera title, status symbol, but no recordings Covert 2 Users without relevant access see only camera title, but no recordings Devices Symbol Camera PTZ Meaning No. Number of camera Product PTZ camera type as per specified list ID Unique ID of PTZ camera Port Interface type of PTZ cameras Settings as specified by PTZ camera manufacturer: Baud Rate Setup… Data Bit Stop Bit Parity DTR-20XX 37 Setup menu, continued Devices – Audio On the “Audio” menu the audio outputs are assigned to the cameras. Setup menu... Term Devices Symbol Audio Meaning No. Number of audio output Associated Camera Assignment of camera Enable Audio-Out Enables all audio outputs 38 DTR-20XX Setup menu, continued Devices – Alarm-Out On the “Alarm-Out” menu the alarm outputs are configured. ● “Settings” tab: The alarm outputs are configured. ● “Schedule” tab: Time slots are defined in which the alarm outputs respond in specific ways. Setup menu... Term Devices Symbol Alarm-Out Settings Meaning No. Number of alarm output Title Name of alarm output Contact method of alarm output: Type Dwell time Setup menu... Term NO Normally Open NC Normally Closed Duration of alarm signal Devices Symbol Alarm-Out Schedule Meaning No. Number of schedule entry Day Day of the week Range Time range at 15-minute intervals Response in defined period: Mode Channels DTR-20XX On Continuous alarm Event Alarm in response to event Off No alarm Enable ● alarm outputs ● internal beep by DVR 39 Setup menu, continued Devices – Display On the “Display” menu the mode of on-screen display is configured. ● “OSD” tab: Specify what additional information is displayed on-screen. ● “Main Monitor” tab: Specify how the camera images are displayed on the main monitor. ● “Spot Monitor” tab: Specify which cameras are displayed on the spot monitors. Setup menu... Term Devices Symbol Display Displayed symbol OSD Meaning Status Remote Control Visible when remote control enabled Zoom Visible when Zoom mode enabled Network Visible when DVR operating in a network Freeze & Sequence ● Visible when freeze frame enabled ● Visible when Sequence mode enabled Screen Group 1/4 Free Space Displays number of groups, and their ID numbers ● Visible when Recycle mode enabled ● Remaining hard disk capacity, if Recycle mode not selected Archive Visible when archiving in progress Date - Date display Time - Time display User Name - Display of user name No. - Display of camera number Title - Display of camera title Camera Record Display of Record symbols PTZ Visible when PTZ camera is displayed Text-In - Display of character string Transparency - Transparency of menu screens - Distance of displayed symbols from screen margin OSD Margin... 40 DTR-20XX Setup menu, continued Setup menu... Term Devices Symbol Display Main Monitor Meaning Modes of sequences in multiple playback: Mode Full Sequence All cameras are switched through sequentially. Cameo Sequence Only the image at the bottom right is switched through; cameras in „Covert“ mode are not displayed to users without „Covert“ access. Interval Time interval between picture refresh Event Monitoring On Displays image of relevant camera in full-screen mode when an event occurs Setup menu... Term Devices Symbol Display Spot Monitor Meaning No. Number of spot monitor output Channels ● Cameras ● Display time of recordings from cameras on spot monitor Devices – Remote Control On the “Remote Control” menu the remote control function is configured. Setup menu... Term Port Devices Symbol Remote Control Meaning Interface type of remote control Setup as specified by manufacturer: Baud Rate Setup… Data Bit Stop Bit Parity Remote Control Product DTR-20XX Remote control type as per specified list 41 Setup menu, continued Record – Record On the “Record” menu the basic settings for recordings and their quality are made. Setup menu... Term Recycle Record Symbol Record Meaning Enables automatic overwriting of the oldest recordings when the hard disk is full Note: If not enabled, recording ends when the hard disk is full. Quality of recorded images Resolution Standard CIF High 2CIF Event Record Dwell Duration of recording when an event occurs Auto Deletion Specify time after which automatically deleted Use Panic Recording Enables the panic recording function Duration of panic recording Panic Recording Duration No Limit End panic recording by pressing PANIC button xx min. Panic recording ends after preset time or by pressing PANIC button ips Number of recorded images per second in panic recording Quality Picture quality of the recorded images in panic recording 42 DTR-20XX Setup menu, continued Record – Schedule On the “Schedule” menu the schedule for recording is defined. Setup menu... Record Term Symbol Schedule On Schedule Meaning Enables schedule entries Note: A recording is made only if schedule entries are enabled. Otherwise only panic recording is possible. No. Number of schedule entry Day Day of the week Range Time range at 15-minute intervals Response: Mode Channels No Record - Time Always record in the defined time slot in the quality set for “Time” mode Event Record only in case of event in the defined time slot in the quality set fpr „Event“ mode Time & Event Always record in the defined time slot in the quality set for “Time” mode, also in case of event in the defined time slot in the quality set for “Event” mode Assignment of cameras to schedule Picture data settings in Time and Event modes: Settings ips Number of recorded images per second Quality Picture quality of recorded images Picture data defaults in Time and Event modes: Default. DTR-20XX ips Number of recorded images per second Quality Picture quality of recorded images 43 Setup menu, continued Record – Pre-Event On the “Pre-Event” menu the settings for recording prior to the event are made. Setup menu... Term Record Symbol Pre-Event Meaning No. Activates the cameras ips Number of recorded images per second prior to the event Quality Picture quality of the recorded images prior to the event Recording time prior to the event Dwell 44 Note: The pre-event recording memory capacity is limited. Consequently, the maximum recording time prior to the event, the number of recorded images and picture quality are interdependent. DTR-20XX Setup menu, continued Record – Archive On the “Archive” menu the schedules and settings for archiving are entered. Setup menu... Record Term Symbol Archive On Archive Meaning Enables the archiving settings Schedule Day Day of week from which to archive recordings Range Time range Archive Data Range Start of archiving, from: From Last Archived Time of last archiving xx/yy/200x Defined date and time End of archiving, up to: To Continue No end xx/yy/200x Defined date and time Enables automatic overwriting of the oldest recordings when the archive medium is full. Recycle Note: If not enabled, archiving ends when the archive medium is full. Summary Archive Enables the Summary Archive function Quality of archived images in summary archive Recording at xx images/s Number of images per second Picture quality of archived images 1 to 15 1 Reduced 16 to 29 1 to 2 Normal 30 2 Normal DTR-20XX 45 Setup menu, continued Event – Alarm-In On the “Alarm-In” menu the alarm inputs and responses to events are configured. Setup menu... Term Event Symbol Alarm-In Settings Meaning No. Enables the alarm inputs Title Name of alarm input Contact method of alarm input: Type Term Normally Open NC Normally Closed Select alarm input for which the function of panic recording should be activated Panic Record Setup menu... NO Event Symbol Alarm-In Actions 1 Meaning No. Number of alarm input Record Assignment of cameras to record in event of alarm These cameras must be in “Event” or “Time and Event” mode within the time slot: Setup menu > Record > Schedule Alarm-Out Assign and enable ● alarm outputs ● internal beep by DVR These alarm outputs and the internal beep must be enabled within the time slot: Setup menu > Devices > Alarm-Out > Schedule Assign and enable notifications: Mail Modem Notify LAN 1 to LAN 5 Alert Window The selected function must be enabled: Setup menu > Network > Notification 46 DTR-20XX Setup menu, continued Setup menu... Term Event Symbol Alarm-In Actions 2 Meaning No. Number of alarm input PTZ Select PTZ cameras to record in event of alarm and select the desired settings Spot Monitor Select spot monitor on which camera image is displayed in event of alarm DTR-20XX 47 Setup menu, continued Event – Motion Detection On the “Motion Detection” menu the motion-sensitive zones are defined and responses to events configured. Setup menu... Term No. Event Symbol Motion Detection Settings Meaning Enables motion detection for the camera Sensitivity of motion detection: Sensitivity Daytime Nighttime Select the motion-sensitive blocks within the time slot Left mouse button functions: ● Click to select/deselect ● Click - hold down - drag to define a zone for selection/deletion/back Right mouse button functions or menu in time slot to select blocks: Zone Min. Blocks Select Select complete row of blocks Clear Clear selection of a row Reverse Reverse selection of a row Select All Select all blocks Clear All Clear selection of all blocks Reverse All Reverse selection of all blocks Specify in how many motion-sensitive blocks motion must be detected as a minimum to trigger an alarm: Daytime Nighttime Zone View Mark the motion-sensitive zones (red in event of motion) Motion Ignoring Interval Time interval between 2 events logged as separate events: Daytime Setup Definition of “Daytime” time range 48 Never Each motion detection is logged as a separate event. DTR-20XX Setup menu, continued Setup menu... Term Event Symbol Motion Detection Actions 1 Meaning No. Number of alarm input Record Assignment of cameras to record in event of alarm These cameras must be in “Event” or “Time and Event” mode within the time slot: Setup menu > Record > Schedule Assign and enable ● alarm outputs ● internal beep by DVR Alarm-Out These alarm outputs and the internal beep must be enabled within the time slot: Setup menu > Devices > Alarm-Out > Schedule Assign and enable notifications: Mail Modem Notify LAN 1 to LAN 5 Alert Window The selected function must be enabled: Setup menu > Network > Notification Setup menu... Term Event Symbol Motion Detection Actions 2 Meaning No. Number of alarm input PTZ Select PTZ cameras to record in event of alarm and select the desired settings Spot Monitor Select spot monitor on which camera image is displayed in event of alarm DTR-20XX 49 Setup menu, continued Event – Video Loss On the “Video Loss” menu checking for covert cameras and the responses to events are configured. Setup menu... Term Event Symbol Video Loss Settings Meaning Sensitivity of check as to whether camera is covert: Check Obscuration Setup menu... Term Event Symbol Never not checked 255 very sensitive Video Loss Actions 1 Meaning No. Number of covert camera Record Assignment of cameras to record in event of alarm These cameras must be in “Event” or “Time and Event” mode within the time slot: Setup menu > Record > Schedule Alarm-Out Assign and enable ● alarm outputs ● internal beep by DVR These alarm outputs and the internal beep must be enabled within the time slot: Setup menu > Devices > Alarm-Out > Schedule Assign and enable notifications Mail Modem Notify LAN 1 to LAN 5 Alert Window The selected function must be enabled: Setup menu > Network > Notification 50 DTR-20XX Setup menu, continued Setup menu... Term Event Symbol Video Loss Actions 2 Meaning No. Number of covert camera PTZ Select PTZ cameras to record in event of alarm and select the desired settings Spot Monitor Select spot monitor on which camera image is displayed in event of alarm DTR-20XX 51 Setup menu, continued Event – Text-In On the “Text-In” menu the text input device is defined and the responses to text input are configured. Setup menu... Term Event Symbol Text-In Settings Meaning No. Number of text input device Setup Configuration of text input >> Title Name of text input Setup Term Port Symbol Meaning Interface Setting as specified by manufacturer of text input device (ATM, cash-till etc.): Setup… Baud Rate Data Bit Stop Bit Parity Type of text input: Text-In Product Generic Text Epson Transaction Start Character string with which text input must start for the DVR to respond Any Character DVR responds to any character Transaction End Character string with which text input must end for the DVR to respond 0 more line(s) Enables recording of n more lines Line Delimiter Line delimiter as specified by the text input device manufacturer: ^J for LF or ^M for CR Ignore String Character string in the text input which the DVR is to ignore All transmittable character strings are specified by the text input device manufacturer. Case Sensitive Case sensitivity according to text input device manufacturer’s specification 52 DTR-20XX Setup menu, continued Setup menu... Term Event Symbol Text-In Actions 1 Meaning No. Number of alarm input Record Assignment of cameras to record in event of alarm These cameras must be in “Event” or “Time and Event” mode within the time slot: Setup menu > Record > Schedule Assign and enable ● alarm outputs ● internal beep by DVR Alarm-Out These alarm outputs and the internal beep must be enabled within the time slot: Setup menu > Devices > Alarm-Out > Schedule Assign and enable notifications: Mail Modem Notify LAN 1 to LAN 5 Alert Window The selected function must be enabled: Setup menu > Network > Notification Setup menu... Term Event Symbol Text-In Actions 2 Meaning No. Number of alarm input PTZ Select PTZ cameras to record in event of alarm and select the desired settings Spot Monitor Select spot monitor on which camera image is displayed in event of alarm DTR-20XX 53 Setup menu, continued Event – System Event On the “System Event” menu the self-diagnostics and corresponding messages are configured. Setup menu... Term Event Symbol System Event Health Check Meaning System System self-diagnostics interval Check Recording Setup... . Configuration of schedule >> Check Alarm-In Interval and status for checking alarm inputs Setup Term Symbol Meaning Schedule On Enables schedule entries No. Number of schedule entry Day Day of the week Range Time range at 15-minute intervals Interval Checking interval Setup menu... Term Event Symbol System Event Storage Meaning Disk Bad Notify Percentage of bad sectors on hard disk as from which an alarm is triggered Disk Almost Full Notify Percentage hard disk space available as from which “Disk Almost Full” alarm is triggered Setup… Configuration of data media S.M.A.R.T. check Opens a window in which the frequency rate and time and a temperature limit (in Celsius or Fahrenheit) for the S.M.A.R.T. check can be specified. If the temperature limit is exceeded an alarm is triggered. For details of your hard disk’s temperature limit refer to the manufacturer’s manual. 54 DTR-20XX Setup menu, continued Setup menu... Term Event Symbol System Event Actions Meaning Events (based on checks): Event Alarm-Out System System check failed Panic Record Panic recording in progress Check Recording Recording check failed Check Alarm-In Check of alarm inputs failed Disk Almost Full Preset limit value for hard disk capacity reached Disk Full Hard disk full Disk Bad Preset limit value for number of bad sectors reached Disk Temperature Preset temperature limit reached Disk S.M.A.R.T. S.M.A.R.T. check failed Assign and enable ● alarm outputs ● internal beep by DVR Note: Not possible for system event and panic recording Assign and enable notifications: Mail Notify Modem (not in case of system event) LAN 1 to LAN 5 (not in case of system event) Alert Window (not in case of system event) The selected function must be enabled: Setup menu > Network > Notification DTR-20XX 55 Setup menu, continued Event – Event Status The “Event Status” menu indicates the status of all possible events: ● Grey text: Event detection not enabled ● White text: Event detection enabled ● Flashing border: Message – acute event for 5 sec ● Yellow field: Pending event Setup menu... Event Event Status Event Status Term Event Alarm-In At alarm input 1 to 16 Check Alarm-In Error detected at one of alarm inputs 1 to 16 Motion Motion detected on camera 1 to 16 Video Loss Video loss on camera 1 to 16 Text-In Text input on text input device 1 to 16 Panic Record Panic recording Check Recording On checking the recording Disk Almost Full On checking the data medium (only if DVR is not operating in Overwrite mode) Disk Full On checking the data medium (only if DVR is not operating in Overwrite mode) Setup menu... Event Event Status Term Meaning Type Memory type Disk Bad Data carrier status Temperature Data carrier status S.M.A.R.T. Result of S.M.A.R.T. check 56 Storage DTR-20XX Specifications DTR-2009 Model DTR-2009/250CD DTR-2009/500CD DTR-2009/750CD EDP no. 71943 71944 71945 Video standard PAL/NTSC (auto detection) Remark Recommended LCD monitors: see Accessories Event logs Unlimited number of entries for alarm/event/text messages, loss of signal Security against unauthorised use Key locking, 64 user groups with programmable access (up to 256 users) Transmission rate 100 images per sec (PAL) Alarm triggering E-mail, pager, remote SW (RAS) Alarm activation Automatic multi-screen display of alarm images programmable Remote control Wireless IR remote control (included) Text display interface ATM/POS, 10 channels max. Monitor display Real-time playback: 25 field images per sec (PAL), 30 field images per sec (NTSC) per camera Covert camera mode Programmable Time synchronisation Network time protocol, network time server System change log Up to 5000 entries for login/logout, configuration changes, remote access, change of signal connection, disk read/write errors Zoom function 2x~4x Playback Frame image, 4-/9-channel split, PIP Post-alarm recording Up to 15 minutes VGA VGA playback recommended only on monitors with Multisync function Control interface RS-485 port for PTZ control (verified protocols: eneo-Fastrax, Pelco P/D) or keyboard connection for remote control Activity detection Programmable 16 x 16 (256) grid, 5 sensitivity settings Simplex/Duplex/Triplex/Pentaplex mode Duplex Video inputs 9x 1 Vp-p, (F)BAS, 75 Ohm, BNC, loop-through Monitor outputs 4x spot outputs 1 Vp-p, (F)BAS, 75 Ohm, BNC Video output 1x 1 Vp-p, (F)BAS, 75 Ohm, BNC; 1x S-VHS, S= 1 Vp-p, C= 0.3 Vp-p, 75 Ohm Audio input 4x amplifier input, cinch Audio output 1x amplifier output, cinch Resolution 720 x 576 pixels (display) Compression method MPEG-4, higher compression rates with same picture quality enable maximum recording times Recording speed 100 field images per sec at CIF resolution (336 x 272 pixels/PAL), 50 field images per sec at 2CIF resolution (672 x 272 pixels/PAL) DTR-20XX 57 Specifications DTR-2009, continued Model DTR-2009/250CD Picture size Basic: 2/2.4 KB; Standard: 4/4.8 KB; High: 8/9.6 KB; Very high: 12/14.4 KB (NTSC/PAL). 2 times larger in High Resolution mode DTR-2009/500CD Hard disk capacity 250 GB ATA hard disk, expandable to as many as 3 internal hard disks Playback speed 100 field images per sec at CIF resolution (336 x 272 pixels/PAL) and Duplex Export of picture data via USB 2.0, SCSI port, CD writer. Network data export: Clip Player, AVI, JPG, BMP Alarm inputs 9x TTL, programmable as NC/NO (terminal strip) Alarm outputs 9x TTL, open collector (terminal strip) Alarm reset 1x TTL (terminal strip) Alarm messages System error, hard disk error 500 GB ATA hard disk, expandable to as many as 3 internal hard disks DTR-2009/750CD 750 GB ATA hard disks Pre-alarm recording Up to 30 minutes Recording medium ATA-2 (EIDE) hard disks, built-in CD-RW writer Archiving With EIDE, SCSI and USB hard disks. Real-time mirroring Menu languages German, English, Italian, French, Spanish, Polish, Russian, Czech, Hungarian Ethernet port 10Base-T, 100Base-TX, RJ-45 Remote software For remote administration and image search function (RAS plus included) Ports 3x USB, 1x RS-485, 1x RS-232 (remote control/configuration or modem), 1x SCSI for memory expansion Power Supply 100 VAC~230VAC, 50/60Hz Power consumption approx. 150 W Temperature range 5°C to 40°C Housing Metal with plastic front panel Colour Pantone 427C Dimensions (H x W x D) 88 x 430 x 405 mm Weight approx. 10.2 kg 58 DTR-20XX Specifications DTR-2016 Model DTR-2016/250CD DTR-2016/500CD DTR-2016/750CD EDP No. 71946 71947 71948 Video standard PAL/NTSC (auto detection) Remark Recommended LCD monitors: see Accessories Event logs Unlimited number of entries for alarm/event/text messages, loss of signal Security against unauthorised use Key locking, 64 user groups with programmable access (up to 256 users) Transmission rate 100 images per sec (PAL) Alarm triggering E-mail, pager, remote SW (RAS) Alarm activation Automatic multi-screen display of alarm images programmable Remote control Wireless IR remote control (included) Text display interface ATM/POS, 10 channels max. Monitor display Real-time playback: 25 field images per sec (PAL), 30 field images per sec (NTSC) per camera Covert camera mode Programmable Time synchronisation Network time protocol, network time server System change log Up to 5000 entries for login/logout, configuration changes, remote access, change of signal connection, disk read/write errors Zoom function 2x~4x Playback Frame image, 4-/9-/16-channel split, PIP Post-alarm recording Up to 15 minutes VGA VGA playback recommended only on monitors with Multisync function Control interface RS-485 port for PTZ control (verified protocols: eneo-Fastrax, Pelco P/D) or keyboard connection for remote control Activity detection Programmable 16 x 16 (256) grid, 5 sensitivity settings Simplex/Duplex/Triplex/Pentaplex mode Duplex Video inputs 16x 1 Vp-p, (F)BAS, 75 Ohm, BNC, loop-through Monitor outputs 4x spot outputs 1 Vp-p, (F)BAS, 75 Ohm, BNC Video output 1x 1 Vp-p, (F)BAS, 75 Ohm, BNC; 1x S-VHS, S= 1 Vp-p, C= 0.3 Vp-p, 75 Ohm Audio input 4x amplifier input, cinch Audio output 1x amplifier output, cinch Resolution 720 x 576 pixels (display) Compression method MPEG-4, higher compression rates with same picture quality enable maximum recording times Recording speed 100 field image per sec at CIF resolution (336 x 272 pixels/PAL), 50 field image per sec at 2CIF resolution (672 x 272 pixels/PAL) DTR-20XX 59 Specifications DTR-2016, continued Model DTR-2016/250CD Picture size Basic: 2/2.4 KB; Standard: 4/4.8 KB; High: 8/9.6 KB; Very high: 12/14.4 KB (NTSC/PAL). 2 times larger in High Resolution mode DTR-2016/500CD Hard disk capacity 250 GB ATA hard disk, expandable to as many as 3 internal hard disks Playback speed 100 field image per sec at CIF resolution (336 x 272 pixels/PAL) and Duplex Export of picture data via USB 2.0, SCSI port, CD writer. Network data export: Clip Player, AVI, JPG, BMP Alarm inputs 16x TTL, programmable as NC/NO (terminal strip) Alarm outputs 16x TTL, open collector (terminal strip) Alarm reset 2~4 TTL (terminal strip) Alarm messages System error, hard disk error 500 GB ATA hard disk, expandable to as many as 3 internal hard disks DTR-2016/750CD 750 GB ATA hard disks Pre-alarm recording Up to 30 minutes Recording medium ATA-2 (EIDE) hard disks, built-in CD-RW writer Archiving With EIDE, SCSI and USB hard disks. Real-time mirroring Menu languages German, English, Italian, French, Spanish, Polish, Russian, Czech, Hungarian Ethernet port 10Base-T, 100Base-TX, RJ-45 Remote software For remote administration and image search function (RAS plus included) Ports 3x USB, 1x RS-485, 1x RS-232 (remote control/configuration or modem), 1x SCSI for memory expansion Power Supply 100 VAC~230VAC, 50/60Hz Power consumption approx. 150 W Temperature range 5°C to 40°C Housing Metal with plastic front panel Colour Pantone 427C Dimensions (H x W x D) 88 x 430 x 405 mm Weight approx. 10.2 kg 60 DTR-20XX Accessories EDP No. Short description 71857 250GB hard disk for DLR/DXR/DTR and DCR 71919 500GB hard disk for DLR/DXR/DTR and DCR 74088 System keyboard with 3-axis joystick 74092 System keyboard with joystick, 5” monitor 71902 USB mouse for DVR series DXR, DLR3 90392 15” LCD industrial colour monitor, 1024x768 90393 17” LCD industrial colour monitor, 1280x1024 90430 19” LCD industrial colour monitor, 1280x1024 90443 17” LCD colour monitor, 1280x1024 pixels 90467 32” prof. 16:9 TFT colour monitor, 4x FBAS 90476 23” prof. 16:9 LCD colour monitor, 4x FBAS DTR-20XX 61 Supported PTZ cameras Manufacturer Designation Manufacturer Designation Costar CDC 2500 Ademco Video Orbiter Microsphere Dyna Color CDC2400 SysMania ORX_1000 Chilsung CRD-J6416 Linlin PIH-717 Fine CRR-1660s ELMO PTC-200C/CVAS Pelco D-protocol ELMO PTC-250C Dennard Dennard2060 Pacom Pacom 2036 Tokina DMP-1223 Dongyang Power Controller Dongyang Unitech DRX-500 Sungjin Receiver/MPU Dongyang DY-255RXC Costar SIC722V Sensormatic Delta Dome II/Ultra IV Samsung Techwin SPD 1600 Eneo Fastrax Samsung Samsung Dome Philips G3 Basic AutoDome Pelco Spectra Dome LG Honeywell) GRU604A Samsung Techwin SRX-100B JVC TK-S576 Hitron Speed Dome Sensormatic Ultra VI Canon VC-C4 Canon VC-C50i Inter-M VRX-2201 Vicon Vicon Hitron 22x AF Zoom 360Vision VisionDome Panasonic WJ-SX550A Panasonic WV-CS850/854 CBC ZC-SD622J Samsung Zoom Camera Honeywell HDC-655 LG Honeywell HSD-25X Honeywell HSDN-251 Idis IRX-100 Ultrak KD6 Ultrak KD6 Z-series Kalatel KTD-312 LG LPT-A100L Novus-C Samsung 62 MRX-1000 DTR-20XX Index A Accessories 61 Alarm Configuring inputs 46 Configuring outputs 39 Connecting inputs 8 Connecting outputs 8 Motion detection 49 Resetting 9 Setting schedule for outputs 39 Setting signal duration 39 Ambient conditions 3, 58 Archiving Configuring 45 Memory requirement 20, 45 Setting schedule 45 Assigning cameras Alarm-In 46 Motion detection 48, 49 Text-In 53 Video loss 50 Assigning PTZ cameras Alarm-In 47 Motion detection 48, 49 Text-In 53 Video loss 51 B Basic functions 7 C Calendar search 22 Cameo 41 Cleaning 3 Clip-Copy 26 Configuring a pre-event 44 Configuring audio outputs 38 Configuring cameras 37 Configuring event responses 46 Configuring motion detection 48 Configuring notification 36 Configuring panic recording 42 Configuring PTZ cameras 37 Configuring remote control 41 Configuring text input as event 52 Configuring video loss as event 50 Connecting cameras 8 Connections 8 DTR-20XX Control options 7 Control protocols 62 Controls Front panel controls 9 Remote control 11 Copying recordings 26 Covert camera setup 19, 37 Covert mode 19, 37 D Date setting 29 Defining motion-sensitive zones 48 Display Configuring 40 Hiding 19, 37 Displaying event status 56 Display menu Access 14 Disposal 66 DVRNS Network configuratio 35 Dwell time 39 E E-mail notification 36 EMC class 3 Enabling notification Alarm-In 46 Motion detection 49 System event 55 Text-In 53 Video loss 50 Event Configuring a pre-event 44 Configuring responses 46 Defining motion-sensitive zones 48 Displaying status 56 Setting recording time 42 System events 54 Text input 52 Video loss 50 Event log 23 F Front panel controls 9 Controls 9, 10 63 Index, continued G R Getting started Video recorder 3, 16 Recordings Copying 26 Deleting 18 Memory requirement 20 Searching 21 Setting schedule 43 Recycling the device 66 Remote control Controls 11 Setting system ID 16, 28 Reset 8, 19 Restoring factory defaults 19 H Health check 54 I IP address 34, 35 L LAN Network configuration 34 M Memory requirement Archiving 20, 45 Recordings 20 Memory type 30 Menu descriptions Search menu 21 Setup menu 27 Menu structure 12 Modem Network configuration 34 Monitor Configuring display 40 Configuring display sequence 41 Connecting 8 Motion search 25 N Network configuration 33 Network settings DVRNS 35 LAN 34 Modem 34 P Package contents 7 PANIC 9, 42 PTZ-menu Access 14 PTZ cameras Connecting 8 Supported cameras 62 64 S Safety instructions 3 Schedule Setting for alarm 39 Setting for archiving 45 Setting for recording 43 Search Calendar search 22 Event log 23 Motion search 25 Text-In 24 Search-menu Access 15 Setting a password 32 Setting automatic overwrite 42 Setting group access privileges 32 Setting menu language 28 Setting recording quality 42 Setting recording time when events occur 42 Setting system ID for remote control 28 Setting up user groups 32 Setting up users 32 Setup menu Access 15 Menu descriptions 27 Shutdown 17 Software updates 19 Software version 28 Specifications 57 Specifying public holidays 29 Spot monitor Assigning camera 41 Connecting 8 DTR-20XX Index, continued Storage media Displaying status 30 Displaying usage 30 Setting automatic overwrite 42 Switching off 17 Switching on 17 System Exporting configuration 28 Importing configuration 28 Log out USER 33 Shutdown 33 System events Configuring 54 Health check 54 T Text-in search 24 Time Setting 29 Synchronising 29 DTR-20XX 65 Notes on disposal Correct disposal of this DVR WEEE (Waste Electrical & Electronic Equipment) Applicable in the member states of the European Union and other European countries with a separate collection system The marking on the DVR and on the documentation stipulates that it must not be thrown away in normal domestic waste at the end of its useful life. General rules ► Avoid uncontrolled waste disposal: Please dispose of this DVR separately from other waste, so as to avoid posing a hazard to the environment and to human health. ► Recycle the DVR in order to aid the sustainable reuse of material resources. Private users ► Contact the retailer from whom you purchased the DVR or your competent local authority to find out how you can recycle the DVR in an environmentally friendly way. Commercial users ► This DVR must not be thrown away with trade waste. To clarify the conditions of disposal, check your purchase contract or contact your supplier. 66 DTR-20XX eneo® is a registered trademark of Videor Technical E. Hartig GmbH Exclusive distribution through specialised trade channels only. VIDEOR TECHNICAL E. Hartig GmbH Carl-Zeiss-Str. 8 · 63322 Rödermark, Germany Tel. +49 (0) 6074 / 888-0 · Fax +49 (0) 6074 / 888-100 www.videortechnical.com Operating Instructions version 08/2007 (V1.6) Subject to technical change without notice. © Copyright by VIDEOR TECHNICAL 2007 ">
Advertisement