Bulletin No. MLPS-I
Drawing No. LP0231
Released 4/03
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839 www.redlion-controls.com
MODEL MLPS - MICRO-LINE POWER SUPPLY
!
PROVIDES +12 VDC POWER TO BACKLIGHT VERSIONS OF
THE MICRO-LINE SERIES
!
115/230 VAC SWITCH SELECTABLE
!
12 VDC OUTPUT @ 80 mA
!
EASILY ATTACHED TO BACKLIGHT VERSIONS
UL Recognized Component,
File # E143054
DESCRIPTION
The Model MLPS is a +12 VDC power supply designed to attach to the rear of backlight versions of the Micro-Line Series. The MLPS can be powered from either a 115 VAC or 230 VAC source and is switch selectable.
Caution: The maximum output current of the MLPS is 80 mA. Check the specifications of the specific counter(s)/indicators(s) and sensors(s) being used to ensure that total current requirements do not exceed 80 mA.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
CAUTION: Read complete instructions prior to installation and operation of the unit.
CAUTION:
Risk of electric shock.
SPECIFICATIONS
1. POWER REQUIREMENTS: Switch selectable 115/230 VAC (±10%),
50/60 Hz, 3 VA. The unit is shipped from factory in the 230 VAC position.
2. POWER OUTPUT: +12 VDC (+5/-25%) @ 80 mA max.
The MLPS is listed in the UL Recognized Component Directory Category
QQFU2 as having an Output category (OC) of NEC Class 2.
3. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 60°C
Storage Temperature: -30 to 75°C
Operating and Storage Humidity: 85% max. (non-condensing) from 0°C to 50°C.
Altitude: Up to 2000 meters
4. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Recognized Component, File # E143054, UL1012, CSA 22.2 No. 107.1
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories Inc.
ORDERING INFORMATION
MODEL NO.
MLPS
DESCRIPTION
Micro Line/Sensor Power Supply
PART NUMBER
MLPS0000
DIMENSIONS In inches (mm)
SPECIFICATIONS (Cont’d)
4. CERTIFICATIONS AND COMPLIANCES: (Cont’d)
IECEE CB Scheme Test Certificate # US/5685/UL
CB Scheme Test Report # 01ME22279-01302002
Issued by Underwriters Laboratories, Inc.
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1.
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
RF conducted interference
EN 61000-4-2 Level 2; 4 Kv contact
Level 3; 8 Kv air
EN 61000-4-3 Level 3; 10 V/m
80 MHz - 1 GHz
EN 61000-4-4 Level 4; 2 Kv I/O
Level 3; 2 Kv power
EN 61000-4-6 Level 3; 10 V/rms
150 KHz - 80 MHz
EN 61000-4-8 Level 4; 30 A/m Power frequency magnetic fields
Emissions to EN 50081-1
RF interference EN 55011 Enclosure class B
Power mains class B
5. CONSTRUCTION: High impact black plastic. Two hex stand-offs and two washers included. Installation Category II, Pollution Degree 2.
6. CONNECTION: Two position terminal block which accepts one 14 AWG wire (torque terminal screws to 5 inch-lbs. [-6Nm]).
7. WEIGHT: 4 oz (113 g)
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate company numbers listed.
INSTALLATION ENVIRONMENT
The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing the unit near devices that generate excessive heat should be avoided.
Installation Procedure
The MLPS is shipped with all the necessary hardware to mount to the rear of an installed backlight version Micro-
Line unit. The user must remove the common and V+ screw terminals on the rear of the Micro-Line unit (Save these screw terminals for later use). Install the
1/4" hex drive stand-offs into the common and V+ terminals. The MLPS is then mounted to the stand-offs using the screw terminals from the compatible
Micro-Line unit with the supplied square washers. AC power can then be connected to the terminal block of the
MLPS.
Note: Make sure the A.C.
selector switch is set to the appropriate position before applying power to the unit.
Red Lion Controls
20 Willow Springs Circle
York PA 17402
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls BV
Basicweg 11b
NL - 3821 BR Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
Red Lion Controls Asia
31, Kaki Bukit Road 3 #06-04/05 TechLink
Singapore 417818
Tel +65 6744-6613
Fax +65 6743-3360