HRPG-150-spec.pdf

HRPG-150-spec.pdf
HRPG-150
150W Single Output with PFC Function
s e r ie s
■  
‧     
‧    
‧    
‧      
‧          
‧    
‧    
‧   
‧   
‧  
‧   
‧    
‧  
SPECIFICATION
MODEL
OUTPUT
HRPG-150-3.3 HRPG-150-5
HRPG-150-7.5 HRPG-150-12 HRPG-150-15 HRPG-150-24 HRPG-150-36 HRPG-150-48
DC VOLTAGE
RATED CURRENT
3.3V
30A
5V
26A
7.5V
20A
12V
13A
15V
10A
24V
6.5A
36V
4.3A
48V
3.3A
CURRENT RANGE
0 ~ 30A
0 ~ 26A
0 ~ 20A
0 ~ 13A
0 ~ 10A
0 ~ 6.5A
0 ~ 4.3A
0 ~ 3.3A
RATED POWER
99W
RIPPLE & NOISE (max.) Note.2 80mVp-p
130W
80mVp-p
150W
100mVp-p
156W
120mVp-p
150W
150mVp-p
156W
150mVp-p
154.8W
200mVp-p
158.4W
240mVp-p
VOLTAGE ADJ. RANGE
4.3 ~ 5.8V
6.8 ~ 9V
10.2 ~ 13.8V
13.5 ~ 18V
21.6 ~ 28.8V
28.8 ~ 39.6V
40.8 ~ 55.2V
±2.5%
±0.5%
±2.5%
±0.5%
±1.5%
±0.3%
±1.5%
±0.3%
±1.5%
±0.2%
±1.5%
±0.2%
±1.5%
±0.2%
±1.0%
±0.5%
±0.5%
3000ms, 50ms /115VAC a t full load
±0.5%
±0.5%
±0.5%
87%
88%
88%
2.8 ~ 3.8V
VOLTAGE TOLERANCE Note.3 ±2.5%
LINE REGULATION
±0.5%
LOAD REGULATION
SETUP, RISE TIME
±1.0%
±1.0%
300 0ms, 50m s/230VAC
HOLD UP TIME (Typ.)
16m s/230VAC
16m s/115VAC at full loa d
Note.5 85 ~ 264VAC
VOLTAGE RANGE
FREQUENCY RANGE
47 ~ 63Hz
INPU T
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
78.5%
2 .3A/115VAC
35A/115VAC
LE AKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
FUNCTION
120 ~ 370VDC
5V STANDBY
REMOTE CONTROL
WORKING TEMP.
WORKING HUMIDITY
PF>0.99/115VAC at full load
84%
86%
1.3A/230VAC
70A/230VAC
87%
87%
105 ~ 135 % rated output power
Protection type : Co nstant cur rent limitin g, recovers automatically after fault condition is removed
3.96 ~ 4.62V
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
41.4 ~ 48.6V
57.6 ~ 67.2V
Protection type : Sh ut down o/p voltage, re-power on to recov er
95℃ (3.3V ~ 7.5V) , 85℃ (12V ~ 48V) (TSW1 : detect on heatsink Q1 of power transistor)
105℃(3.3V ~ 7.5V), 100℃(12V ~ 48V) (TSW2 : detect on heatsink HS4 of power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5VSB : 5V@0.3A ; tolerance ± 5%, ripple : 50mVp-p(max.)
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-co ndensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TE MP. COEFFICIENT
±0.04%/℃ (0 ~ 50℃)
VIBRATION
SAFETY STA NDARDS
SAFE TY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
NOTE
10 ~ 500H z, 5G 10min./1cycle , 60min. e ach along X, Y, Z axe s
UL60950- 1, TUV EN 60950-1 approved
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P -FG:100M Ohms / 5 00VDC / 25℃/ 70% R H
Complian ce to EN55 022 (CISPR22) Class B, EN61000-3-2,- 3
EMC IMMUNITY
Complian ce to EN61 000-4-2,3,4,5,6,8,11, EN5502 4, EN61000-6-2, heavy industry level, c riteria A
MTBF
213.4K hr s min.
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.63Kg; 24pcs/16Kg/0.76CUFT
MIL-HDBK-217F (25℃ )




             ℃   
                      
          
                        
                   
   
                
               
File Name:HRPG-150-SPEC 2013-06-18
HRPG-150
150W Single Output with PFC Function
Mechanical Specification
Case No.901I
s e r ie s
Unit:mm
152.5
1
2
3
4
5
6
7
Termina l Pin No . Assignment
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
CN100
SVR1
Pin No.
Assignment
4,5
DC OUTP UT -V
6,7
DC OUTP UT +V
4.5
24
Pin No. A ssignment
1
-S
2
+S
3
A UXG
4
AUX
5
RC6
RC+
Mating Housing
78
159
Connec tor Pin No. Ass ignmen t (CN100) :
HRS DF11-6DP-2DSA or equiv alent
6.5
150
Terminal
HRS DF11-6DS
or equivalent
10 max.
HRS DF11-**SC
or equivalent
6-M3(Both Sides) L=6
22
117
Block Diagram
ACTIVE
INRUSH
CURR ENT
LIMIT ING
EMI
FILTE R
I/P
AUX
POWER
RECTIFIERS
&
FILTER
RECTIFIERS
&
PFC
P OWER
SWITCHING
RECTIFIERS
&
FILTER
O.T.P.
O.L.P.
fosc :100KHz(3.3~7 .5V)
70 KHz(12 ~48V)
AUX
AUXG
+S
+V
-V
-S
DETECTION
CIRCUIT
O.T.P.
FG
PFC
CONTROL
PWM
CONTROL
Derating Curve
O.V.P.
RC+
REMOTE
CONTRO L
RC-
Output Derating VS Input Voltage
100
100
Without Cover
90
80
80
70
60
With Cover
60
40
50
20
-40
40
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
70
(HORIZONTAL)
85
100
125
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:HRPG-150-SPEC 2013-06-18
HRPG-150
150W Single Output with PFC Function
s e r ie s
Function Description of CN100
Pin No. Function Description
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
1
-S
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
2
3
4
5
6
+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
Auxiliary voltage output, 4.75~5.25V, referenced to pin 3(AUXG). The maximum load current is 0.3A. This output is not controlled by the
AUX "remote ON/OFF control".
RCRC+
Remote control ground.
Turns the output on and off by electrical or dry contact between pin 5 (RC-). Short: Power OFF, Open: Power ON.
Function Manual
1.Remote Control
The PSU c an be tu rned O N/OFF b y using the "Re mote
ON/OFF" f unction
Between RC-(pi n5) and RC+(pin6)
Output Statu s
SW ON (Short)
OFF
SW OFF (Open)
ON
CN100
6
RC+
AUX
5
RC- AUXG
6
RC+
5
RC- AUXG
+S
2
-S
1
+S
2
-S
1
SW
-V
-V +V
+V
CN100
642
531
LOA D
-
+
Fig 1.1
2.Remote Sense
The remote sen sing co mpensates volt age drop on the
load wiring up t o 0.5V.
-V
-V +V
+V
CN100
642
531
-S
(Pin 1)
LOAD
-
+
+S
(Pin2)
Sens e l ines s hould
be t wis ted in pairs
CN100
AUX
Fig 2.1
File Name:HRPG-150-SPEC 2013-06-18