Sharp | CD-C401E | Basic Serial Command Specification

Basic Serial Command Specification
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
LV-7555 (for MR3P series)
Basic Serial Command Specification
Page
1/26
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
-CONTENT1. Overview
2. Serial Interface Specification
2.1 Communication Specification
2.2 Connection
3. Notes for Communications
4. Functional Execution Command Table
4.1 Statue Read Command Table
5. Functional Execution Command
5.1 Format
5.2 When the command pipelining is needed
5.3 Transfer Example
5.4 Necessary Condition for Operation
5.5 POWER ON Command
5.6 POWER OFF Command (Quick Power OFF)
5.7 POWER OFF Command
5.8 INPUT 1 Command
5.9 INPUT2 Command
5.10 INPU3 Command
5.11 Network Viewer Command
5.12 VOLUME + Command
5.13 VOLUME – Command
5.14 AUDIO MUTE ON Command
5.15 AUDIO MUTE OFF Command
5.16 VIDEO MUTE ON Command
5.17 VIDEO MUTE OFF Command
5.18 REGURLAR VIDEO IMAGE Command
5.19 WIDE VIDEO IMAGE Command
5.20 MENU ON Command
5.21 MENU OFF Command
5.22 DISPLAY CLEAR Command
5.23 BRIGHTNESS + Command
5.24 BRIGHTNESS – Command
5.25 INPUT 2 VIDEO Command
5.26 INPUT 2 Y, Pb/Cb, Pr/Cr Command
5.27 INPUT 2 RGB Command
5.28 IMAGE Command
Page
1/26
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
5.29 ON START SETTING Command
5.30 ON START CONCELATION Command
5.31 POWER MANAGEMENT SETTING Command
5.32 POWER MANAGEMENT CANCELATION Command
5.33 D.ZOOM + Command
5.34 D.ZOOM – Command
5.35 INPUT 3 VIDEO Command
5.36 INPUT 3 S-VIDEO Command
5.37 INPUT 3 Y, Pb/Cb, Pr/Cr Command
5.38 POINTER RIGHT Command
5.39 POINTER LEFT Command
5.40 POINTER UP Command
5.41 POINTER DOWN Command
5.42 MOUSE RIGHT CLICK Command
5.43 ENTER Command
5.44 FREEZE ON Command
5.45 FREEZE OFF Command
5.46 ZOOM + Command
5.47 ZOOM – Command
5.48 FOCUS + Command
5.49 FOCUS- Command
5.50 COLOR. MANAGEMENT Command
5.51 INPUT 1 Analog RGB Command
5.52 INPUT 1 SCART Command
5.53 INPUT 1 DVI (PC Digital) Command
5.54 INPUT1 DVI (AV HDCP) Command
5.55 INPUT 1 Monitor OUT command
5.56 LENES SHIFT + Command
5.57 LENS SHIFT – Command
5.58 AUTO PC ADJ. Command
5.59 PRESENTATION TIME Command
5.60 KEYSTONE UP Command
5.61 KEYSTONE Down Command
5.62 KEYSTONE RIGHT Command
5.63 KEYSTONE LEFT Command
6. State Read Command
6.1 Format
6.2 Transfer Example
Page
1/26
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
6.3 Status Read Command
6.4 Input Mode Read Command
6.5 Lam Time Read command
6.6 Setting Read Command
6.7 Temp Read Command
Page
1/26
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
1. Overview
1.1 This Specification defines projector control commands for MR3P series (1.3 “XGA
V-4LV-7555).
1.2 The projector control commands are for controlling projector through RS232C from a
computer.
2. Serial Interface Specification
2.1 Communication Specification
Specification
Synchro system
Asynchronou
Transmission
9600 / 19200
Speed
Date Length
8 bit
Parity
None
Stop Bit
1
Flow Control
None
1. Transfer rate: initial setting value is 19200.
2. Transfer rate can be changed by service mode
2.2 Connection
Dedicated serial cable that comes with the projector must be used for a connection
to a computer and a projector.
PC
COM No.1
Projector
Control Port
CD
1
1
RXD
TXD
DTR
2
2
3
3
4
4
SG
5
5
DSR
RTS
6
6
7
7
CTS
RING
8
8
9
(D-Sub 9 Pin)
(Mini 8 Pin)
Page
5 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
3. Notes for Communications
3.1 The projector command is defined one command/one line that starts “C” and
ends carriage return (0x0D).
3.2 When a projector receives carriage return (0x0D), it starts decoding.
3.3 There are two type commands, functional execution commands and state read
commands. Functional execution commands works as a remote control and key on
the projector, and State read command works to know the projector status.
Example of Functional Execution Command :”C05” [CR]
Example of State Read Command :”CR0” [CR]
3.4 When it takes more than one second to receive on command, it clears information of
buffer.
(until the projector receives the carriage return since the projector has received the
first data.)
3.5 When control command pipelining, after the response, wait interval of time as below.
3.5.1
“VOLUME
+/-“
”ZOOM
UP/DOW””FOCUS
UP/DOWN”
”LENS-SHIF
UP/DOWN/LEFT/RIGHT” Commands → 100ms
3.5.2 Other Commands → 500 ms
3.6 Wait at least 500ms after the response, when status read command pipelining.
3.7 Do not issue command before the Response in the situation as below, except no
response after 5 seconds.
3.8 It takes about 7 seconds for internal initialization after plugging in AC. During this
time, it cannot process command. Do not issue any commands.
3.9 7 seconds after Stand By or Power ON, Even when a projector receives a command, a
computer receives acceptable response, but it does not execute for internal
initialization and lamp lighting process.
However, Status Read Commands are
executed after 500ms when they receive acceptable response.
3.10 About performance during processing count down or cooling down.
When a projector receives After Stand By or Power ON, Even when a projector
receives a command, a computer receives response to accept the command, but it
does not execute for internal initialization and lamp lighting process.
However,
Status Read Commands are executed after 500ms when a computer receives
acceptable response.
3.11 When a projector receives a command while processing count down after Power ON
or cooling down after Power Off, a computer receives response to accept the
command but the command is not executed.
However, Status Read Commands are executed.
Page
6 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
3.12 About performance when changing INPUT
After receiving INPUT switching command, when receiving commands between 5
seconds from starting the switching to completing the switching, a computer receives
acceptable command, but it is not executed.
However, status read commands are executed after a computer receives response to
accept the command, after 500ms. Response command characters for status read
success are different.
See “7, State Read Command” for the details.
3.13 Command are shown in a capital letter (A ∼ Z). Lower case letters are not
available.
4.
Functional Execution Command Table
Command
C00
C01
C02
C05
C06
C07
C08
C09
C0A
C0B
C0C
C0D
C0E
C0F
C10
C1C
C1D
C1E
C20
C21
C23
C24
C25
C27
C28
C29
C2A
C2B
C30
C31
Item
Command
POWER ON
C33
POWER OFF (Quick Power OFF)
C34
POWER OFF
C35
INPUT 1
C3A
INPUT 2
C3B
INPUT 3
C3C
NETWORK
C3D
VOLUME +
C3E
VOLUME C3F
AUDIO MUTE ON
C43
AUDIO MUTE OFF
C44
VIDEO MUTE ON
C46
VIDEO MUTE OFF
C47
REGULAR VIDEO IMAGE(4:3)
C4A
WIDE VIDEO IMAGE(16:9)
C4B
MENU ON
C4E
MENU OFF
C50
DISPLAY CLEAR
C51
BRIGHTNESS +
C52
BRIGHTNESS C53
INPUT 2 VIDEO
C54
INPUT 2 Y,Pb/Cb,Pr/Cr
C5D
INPUT 2 RGB
C5E
IMAGE
C89
ON START Enable
C8A
ON START Disable
C8E
POWER MANAGEMENT Enable
C8F
POWER MANAGEMENT Disable
C90
D.ZOOM +
C91
D.ZOOM -
Item
INPUT 3 VIDEO
INPUT 3 S-VIDEO
INPUT 3 Y,Pb/Cb,Pr/Cr
POINTER RIGHT
POINTER LEFT
POINITER UP
POINITER DOWN
MOUSE RIGHT CLICK
ENTER
FREEZE ON
FREEZE OFF
ZOOM ZOOM +
FOUCS FOUCS +
COLOR MANAGEMENT
INPUT 1 Analog RGB
INPUT 1 SCART
INPUT 1 DVI (PC Digital)
INPUT 1 DVI (AV HDCP)
INPUT 1 Monitor OUT
LENS SHIFT +
LENS SHIFT AUTO PC ADJ.
PRESENTATION TIMER
KEYSTONE ↑
KEYSTONE ↓
KEYSTONE →
KEYSTONE ←
Page
7 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
3 1. State Read Command Table
Command
CR0
CR1
CR3
CR4
CR6
FUNCTION
Status Read
Input Mode Read
Lamp Time Read
Setting Read
Temp Read
RENARKS
4 Functional Execution Command
4.1
Format
1. PC issues a command as below format.
“C” Command [CR]
Command:2 characters(See Functional Execution Command Table)
2. A projector changes received data to decode and send a return result after
being ready to receive next command.
[ACK][CR]
:
(0x06、0x0D)When a projector receives a functional execution
command.
“?”[CR]:When cannot read receiving data
4.2
When the command pipelining is needed
When some functions need command pipelining, the performance is the same as
the remote control’s performance.
1. System: issue command every 100ms
2. When receiving any relevant command, the function is executed continuously
for 120ms.
3. When receiving the same command continuously with 120ms, the function is
executed for 120ms from that moment.
4. After 120ms, the next command is not issued, the execution is stopped.
5. If the projector receives other incoming commands within 120ms, the
execution is stopped.
4.3
Transfer Example
Change to Video mode with Basic Command
Command
PC → Projector
Projector → PC
“C”
“0” “7”
CR
ACK CR
Command processing
(A few ms ∼ 1s)
Page
8 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.4
Necessary Condition for Operation
When the projector ‘s status in this below, functional execution commands and
state read commands are limited.
Also, state read commands are available in the below the status.
Projector Status
Standby Mode
Processing Countdown
Processing Cooling Down
Processing Cooling Down due to
abnormal temperature
Abnormal Temperature Status
Processing Mode Change
Processing Power Save・Cooling Down
Processing Power Save
Processing cooling down after
turning off automatically due to a
lamp failure
AVAILABLE FUNCTIONAL EXECUTION
COMMANDS
C00:POWER ON
C00:POWER ON
(Terminate Processing Countdown)
C01: POWER OFF
C02: POWER OFF
(Terminate Processing Countdown)
C46: ZOOMC47: ZOOM+
C4A: FOCUSC4B: FOCUS+
C5D: LENS SHIFT +
C5E: LENS SHIFTNote) When executing ZOOM+/-, FOCUS+/-.
LENS SHIFT +/- during Countdown,
C3C/C3D that are Pointer UP/DOWN will
be available. C3C/C3D commands can
control ZOOM/FOCUS/LENS SHIFT.
NONE
NONE
NONE
NONE
NONE
C00:POWER ON
C01:POWER OFF
Other commands: POWER ON
NONE (Even if the projector receives
commands, it does not execute it)
Notice)When the status is above, even if the projector receives other command in the above
status, the projector returns [ACK][CR].
4.5
POWER ON Command
Command
Detail
Response
“C00” [CR]
Power ON
When already Power ON, no need to do.
When sending this command during processing Count Down, Count Down is
terminated.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
9 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
POWER OFF Command(Quick Power OFF)
4.6
Command
Detail
Response
“C01” [CR]
Power OFF (Stand By)
When Power OFF with ON-OFF button of the projector or the remote control,
“Power OFF” will be displayed. However, as soon as this command is sent,
Quick Power OFF is executed.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
POWER OFF Command
4.7
Command
Detail
Response
“C02” [CR]
Power OFF (Stand By)
When Power OFF with ON-OFF button of the projector or the remote control,
“Power OFF” will be displayed. However, as soon as this command is sent,
Power OFF is executed.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 1 Command
4.8
Command
Detail
Response
“C05” [CR]
Select Input 1
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 2 Command
4.9
Command
Detail
Response
4.10
Command
Detail
Response
“C06” [CR]
Select Input 2
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 3 Command
“C07” [CR]
Select Input 3
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
10 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.11
Command
Detail
Response
4.12
Command
Detail
Response
4.13
Command
Detail
Response
4.14
Command
Detail
Response
4.15
Command
Detail
Response
Network Viewer Command
“C08” [CR]
Select Input Network
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
VOLUME + Command
“C09” [CR]
Volume Up
This Command works same as “VOLUME +” of the projector and the remote
control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
VOLUME - Command
“C0A” [CR]
Volume Down
This Command works same as “VOLUME +” of the projector and the remote
control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
AUDIO MUTE ON Command
“C0B” [CR]
Sound Mute ON
This command works same as “MUTE” of the projector and the remote control,
but this command does not work for MUTE OFF.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
AUDIO MUTE OFF Command
“C0C” [CR]
Sound Mute OFF
This command works the same as “MUTE” of the Remote Control button for
MUTE OFF, but does not work for “MUTE ON”
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
11 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.16
Command
Detail
Response
4.17
Command
Detail
Response
4.18
Command
Detail
Response
4.19
Command
Detail
Response
4.20
Command
Detail
Response
4.21
Command
Detail
Response
VIDEO MUTE ON Command
“C0D” [CR]
VIDEO MTUE ON
This command works same as “NO SHOW” of the remote control, but does not
work for “NO SHOW OFF”.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
VIDEO MUTE OFF Command
“C0E” [CR]
VIDEO MUTE OFF
This command works the same as “NO SHOW” of remote control button for
VIDEO MUT OFF, but does not work for No Show ON”.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
REGULAR VIDEO IMAGE Command
“C0F” [CR]
Set video screen size to Regular(4:3).
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
WIDE VIDEO IMAGE Command
“C10” [CR]
Set video screen size to Wide(16:9).
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
MENU ON Command
“C1C” [CR]
Display Menu of On Screen Display
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
MENU OFF Command
“C1D” [CR]
Off Menu of On Screen Display
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
12 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.22
Command
Detail
Response
4.23
Command
Detail
Response
4.24
Command
Detail
Response
4.25
Command
Detail
Response
4.26
Command
Detail
Response
4.27
Command
Detail
Response
DISPLAY CLEAR Command
“C1E” [CR]
Clear the On Screen Display.
Clear the On Screen Display unconditionally
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
BRIGHTNESS + Command
“C20” [CR]
Brightness of user control +1
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
BRIGHTNESS - Command
“C21” [CR]
Brightness of user control -1
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 2 VIDEO Command
“C23” [CR]
Select Video Input for Input 2.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 2 Y,Pb/Cb,Pr/Cr Command
“C24” [CR]
Select Y, Pb/Cb, Pr/Cr Input for Input2
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 2 RGB Command
“C25” [CR]
Select RGB Input for Input 2.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
13 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.28
Command
Detail
Response
4.29
Command
Detail
Response
4.30
Command
Detail
Response
4.31
Command
Detail
Response
4.32
Command
Detail
Response
IMAGE Command
“C27” [CR]
Change IMAGE setting status.
Works same as the remote control’s “image button”.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
ON START SETTING Command
“C28” [CR]
Set to Power ON Start setting status
This setting status is stored in EEPROM, even if the power is ON/OFF.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
ON START CANCELATION Command
“C29” [CR]
Cancel Power ON Start
This status is stored in EEPROM even when power is ON or OFF.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
POWER MANAGEMENT SETTING Command
“C2A” [CR]
Set Power Management.
This status is stored in EEPROM even when power is ON or OFF.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
POWER MANAGEMENT CANCELATION Command
“C2B” [CR]
Cancel Power Management Setting.
This status is stored in EEPROM even when power is ON or OFF.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
14 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.33
Command
Detail
Response
4.34
Command
Detail
Response
4.35
Command
Detail
Response
4.36
Command
Detail
Response
4.37
Command
Detail
Response
4.38
Command
Detail
Response
D.ZOOM + Command
“C30” [CR]
Digital Zoom Mode: Zoom in
This command works same as the remote control “D.ZOOM UP” button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
D.ZOOM _ Command
“C31” [CR]
Digital Zoom Mode: Zoon out
This command works same as the remote control “D.ZOOM DOWN” button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 3 VIDEO Command
“C33” [CR]
Select Video Input for Input 3
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 3 S-VIDEO Command
“C34” [CR]
Select S-Video Input for Input 3.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 3 Y,Pb/Cb,Pr/Cr Command
“C35” [CR]
Select Y, Pb/Cb, Pr/Cr Input for Input 3.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
POINTER RIGHT Command
“C3A” [CR]
Move the pointer on Menu of ON Screen Display to the right.
This command is different from point buttons “>” of the projector.
Volume +/- function.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
There is no
15 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.39
Command
Detail
Response
4.40
Command
Detail
Response
4.41
Command
Detail
Response
4.42
Command
Detail
Response
4.43
Command
Detail
Response
4.44
Command
Detail
Response
POINTER LEFT Command
“C3B” [CR]
Move the pointer on Menu of On Screen Display to the left.
This command is different from point buttons “<” of the projector.
Volume +/- function.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
There is no
POINTER UP Command
“C3C” [CR]
Move up the pointer on Menu of On Screen Display.
This command works the same as point buttons “UP ” of the projector.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
POINTER DOWN Command
“C3D” [CR]
Move down the pointer on Menu of On Screen Display.
This command works the same as point buttons “DOWN ” of the projector.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
MOUSE RIGHT CLICK Command
“C3E” [CR]
Works same as “Mouse right click” of the remote control.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
ENTER Command
“C3F” [CR]
This command works the same as “Select” button of the projector.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
FREEZE ON Command
“C43” [CR]
Make the screen Freeze.
This command works the same as the remote control’s FREEZE” button not for
Freeze OFF but for Freeze ON.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
16 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.45
Command
Detail
Response
4.46
Command
Detail
Response
4.47
Command
Detail
Response
4.48
Command
Detail
Response
4.49
Command
Detail
Response
FREEZE OFF Command
“C44” [CR]
Return to Freeze OFF screen.
This command works the same as the remote control’s “FREEZE” button for
Freeze off.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
ZOOM+ Command
“C47” [CR]
Make the screen bigger.
This command works the same as the remote control’s “ZOOM UP” button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
ZOOM- Command
“C46” [CR]
Make the screen smaller.
This command works the same as the remote control’s “ZOOM DOWN” button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
FOCUS+ Command
“C4B” [CR]
Focus on the screen image (sharp and clear) with a long- focal- length (∽)
(the lens direction is backward)
This command works the same as the remote control’s “FOCUS UP” button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
FOCUS- Command
“C4A” [CR]
Focus on the screen image (sharp and clear) with a short- focal- length (the
lens direction is forward)
This command works the same as the remote control’s “FOCUS DOWN”
button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
17 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.50
Command
Detail
Response
4.51
Command
Detail
Response
4.52
Command
Detail
Response
4.53
Command
Detail
Response
4.54
Command
Detail
Response
4.55
Command
Detail
Response
COLOR. MANAGEMENT Command
“C4E” [CR]
Set Color management to ON.
This command works the same as the remote control’s “COLOR.M” button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 1 Analog RGB Command
“C50” [CR]
Select Analog RGB Input for Input 1
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 1 SCART Command
“C51” [CR]
Select Scart Input for Input1
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 1 DVI(PC Digital)Command
“C52” [CR]
Select DVI (PC Digital) Input for Input 1.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 1 DVI(AV HDCP)Command
“C53” [CR]
Select DVI (AV HDCP) Input for Input 1.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
INPUT 1 Monitor OUT Command
“C54” [CR]
Set Input 1 to Monitor OUT.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
18 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
4.56
Command
Detail
Response
4.57
Command
Detail
Response
4.58
Command
Detail
Response
4.59
Command
Detail
Response
4.60
Command
Detail
Response
4.61
Command
Detail
Response
LENS SHIFT+ Command
“C5D” [CR]
Move up the screen.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
LENS SHIFT- Command
“C5E” [CR]
Move down the screen.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
AUTO PC ADJ. Command
“C89” [CR]
Execute Auto PC Adj.
This command works the same as the remote control’s “AUTO PC ADJ” of the
remote control’s button.
While Auto PC Adj is working and a computer issue another command, Auto PC
Adj. Stops.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
PRESENTATION TIMER Command
“C8A” [CR]
Set a presentation timer to active
This command works the same as the remote control “P-TIMER” button.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
KEYSTONE ↑ Command
“C8E” [CR]
Adjust keystone.
Make the screen image length at the top edge shorter.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
KEYSTONE ↓ Command
“C8F” [CR]
Adjust keystone.
Make the screen image length at the bottom edge shorter.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
Page
19 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
KEYSTONE → Command
4.62
Command
Detail
Response
“C90” [CR]
Adjust keystone.
Make the screen image length at the right edge shorter.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
KEYSTONE ← Command
4.63
Command
Detail
Response
“C91” [CR]
Adjust keystone.
Make the screen image length at the left edge shorter.
Acceptable
[ACK] [CR]
Unacceptable
“?” [CR]
5 State Read Command
5.6
Format
5.6.1 A PC issues Command as below format
“CR” Command [CR]
Command:1character(See Status Read Command Table)
5.6.2 When projector receives the appropriate command, it returns a
character line as the required data.
Required Data [CR]
Required Data:a character line
5.6.3 When receiving data cannot be decode, the projector returns”?”[CR].
5.7
Transfer Example
Get input mode for the projector by basic commands.
Command
PC → Projector
“C”
(current input mode command issue)
“R” “1”
CR
Projector → PC
“1”
CR
←---→
Response
(A few ms ∼ 1s)
(shows Computer 1 is selected now.)
Page
20 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
Status Read Command
5.8
Command
Detail
“CR0” [CR]
Get the projector status
Acceptable
Response
%1
Unacceptable
“%1” [CR]
“00” = POWER ON
“80” = STANDBY
“40” = Processing Count Dow
“20” = Processing Cooling Down
“10” = Power Failure
“28” = Processing cooling down due to abnormal temperature
“08” = Abnormal Temperature
“88” = normal after recovering abnormal temperature
“24” = Processing Power Save・Cooling Down
“04” = Power Save
“21” = Processing cooling down after turning off automatically
due to a lamp failure
“81”= Standby after cooling down due to a lamp failure
“?” [CR]
【Details for Response】
5.8.1 “00” [CR]
POWER ON
Normal screen is displayed.
5.8.2
“80” [CR]
STAND BY
When the status is STAND BY, Status Read Commands are always
acceptable, but Functional Execution Commands are not acceptable except
Power ON Command.
5.8.3 “40” [CR]
Processing Count Down
When “Display” in Setting Menu is ON and Power ON is executed, it starts
processing Count Down. Also, when “Display” OFF in the setting menu is
set, processing Count Down is skipped and the status moves to Power ON
quickly.
5.8.4 “20” [CR]
Status: Cooling
When status is Power ON, and Power OFF Command is executed, it moves
to cooling status. This cooling status automatically moves on to Standby
after the lamp turns off and the fan spin for about 90seconds.
The time defers from models. This Cooling Down Works for lamps and other
optical accessories. Control commands are not available for this status.
Page
21 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
5.8.5 “10” [CR]
Abnormal power supply voltage
When the power supply voltage inside the projector reaches abnormal power
supply voltage, the power will be automatically turned off. The projector
returns “10”[CR] and cooling fan is also stopped at the time.
5.8.6
“28” [CR]
Processing Cooling Down because of exceeding critical temperature. When
the temperature inside a projector is out of the operating temperature, it
automatically starts cooling down. Response is “28 (CR) at the time. Even if
when the temperature is processing low, the cooling down is executed.
5.8.7 “08” [CR]
Abnormal Temperature
When the temperature does not go down after cooling down due to the
abnormal temperature, this is the Response. The projector keeps the Stan
By status.
5.8.8 “88” [CR]
Normal status after recovering abnormal temperature.
When the temperature goes down after cooling down and moving to Stand
By status, this is the response.
This status keeps until the next operation. In short, when Power On is
executed, the temperature information is canceled, and works normal.
5.8.9 “24” [CR]
Processing Power Save・Cooling Down
Processing Power Save・Cooling down by the power management function
in the e setting menu.
The control command is invalid.
This Power Save・Cooling Down moves to Power Save after the cooling
down time.
STATUS: No Signal
POWER SAVE・COOLING DOWN
Response:
“24”
”00”
No Signal
POWER SAVE
“04”
COOLING
Page
22 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
5.8.10 “04” [CR]
Status of Power Save
The status is Power Save by the Power management function in setting
menu.
Control commands as below are available in this status.
5.8.11 “21” [CR]
Automatically turning off due to a lamp failure (During cooling down).
When a lamp failure occurs, projector will start cooling down automatically.
The return command is “21” [CR].
During processing cooling down, the
command, “21” [CR] stays.
5.8.12 “81” [CR]
Stanby status after recovering lamp failure.
This is the return command after cooling down and moving on to
standby status.
The Stanby status stays until next command is issued.
In short, when executes Power On, the lamp information is cancelled
and projector performs as usual.
Input Mode Read Command
5.9
Command
Detail
“CR1” [CR]
Get selected Input No.
Acceptable
Response
%1
Unacceptable
5.10
Command
Detail
“1” = Input1is selected
“2” = Input2is selected
“3” = Input3is selected
“4” = Input4(Network Viewer)is selected
“?” [CR]
Lamp Time Read Command
“CR3” [CR]
Get total lamp running hours
Acceptable
Response
“%1” [CR]
%1
Unacceptable
“%1” [CR]
Show as 4 digits
Ex.: “0410”[CR] ・・・・410 hours
“?” [CR]
Page
23 / 24
MR3P Series
Basic Serial Command Function Specification
Soft Engineer Division
5.11
Command
Detail
Setting Read Command
“CR4” [CR]
Get setting status for screen such as Ceiling/Rear.
Acceptable
Response
%1
Unacceptable
5.12
Command
Detail
“11” [CR] = Normal Screen Setting
“10” [CR] = Rotation around the horizontal setting (Rear&
Ceiling ON)
“01” [CR] = Rotation around the horizontal setting Rear ON)
“00” [CR] = Vertical and right-and left (four directions)
reversal setting (status: Ceiling ON)
“?” [CR]
Temp Read Command
“CR6” [CR]
Get the temperature inside a projector.
When some temperature sensors are installed in the projector, it is possible to
know the temperature all at once.
Acceptable
Response
“%1” [CR]
%1
%2
%3
Unacceptable
“%1_%2_%3” [CR]
%1=Temperature, sensor 1
%2=Temperature, sensor 2
%3=Temperature, sensor 3
Temperature data form shows as 00.0.
When the temperature sinks to -, the first character is “-” like
“-05.5” [CR].
When cannot return the temperature data due to hardware
problems, the first character is “E” like”E00.0” [CR].
When some temperature sensors are installed, the projector
sends command continuously.
“_31.5__35.2__33.4” [CR]
There is the first sensor’s information, and after one space,
there is the second sensor’s information.
“?” [CR]
Page
24 / 24
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project