Below you will find brief information for Upconverter UT-4500-A UT-4505-A, Upconverter UT-4500-A UT-4505/E-A, Upconverter UT-4500-A UT-4505/F-A, Upconverter UT-4500-A UT-4505/G-A, Upconverter UT-4500-A UT-4505/H-A, Upconverter UT-4500-A UT-4505/J-A. This manual provides instructions on how to install and operate the Comtech EF Data UT-4500-A Series Upconverters, including information on physical configuration, RF signal conversion, and monitor and control.
Advertisement
Advertisement
UT-4500-A Series
Upconverters
Installation and Operation Manual
IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifications are subject to change without prior notice.
Part Number MN-UT4500A Revision 0
Subject:!
Original!Manual!Part!
Number/Rev:!
Errata A
Comtech EF Data Documentation Update
Add! TPE! and! TPS! Utility! Commands! to! Appendix! A.! REMOTE! CONTROL,!
Sect.!A.7.1!Utility!Commands:!
!
MN"UT4500A!Rev!0!
Errata!Number/!
PLM!Document!ID:!
PLM!CO!Number:!
!
!
!
!
!
!
!
!
Comments:!
!
ER"UT4500A"EA0!
C"0027476!
The!updated!information!will!be!incorporated!into!the!next!formal!revision!
of!the!manual:!!
!
Add! TPE! and! TPS! Utility! Commands! to! Appendix! A.! REMOTE! CONTROL,!
Sect.!A.7.1!Utility!Commands:!
ER-UT4500-EA0 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! PLM CO C-0027476 Page 1 of 2
Errata!A!for!MN"UT4500A!Rev!0!
Add!TPE!and!TPS!Utility!Commands!to!Appendix!A!
!
(Note:!Sects.!A.7.1.3!through!A.7.1.22!will!be!renumbered!to!A.7.1.5!through!A.7.1.24!in!MN"UT4500A!
Revision!1.)!
ER-UT4500-EA0 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! PLM CO C-0027476 Page 2 of 2
UT-4500-A Series
Upconverters
Installation and Operation Manual
Part Number MN-UT4500A
Revision 0
February 2, 2011
Copyright © Comtech EF Data, 2011. All rights reserved. Printed in the USA.
Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161
This page is intentionally blank.
TABLE OF CONTENTS
PREFACE ...................................................................................................................... XI
!
About this Manual ....................................................................................................................... xi
!
Disclaimer .................................................................................................................................. xi
!
Reporting Comments or Suggestions Concerning this Manual ................................................. xi !
Conventions and References ...................................................................................................... xii
!
Cautions and Warnings ............................................................................................................. xii
!
Recommended Standard Designations ..................................................................................... xii !
Trademarks ............................................................................................................................... xii
!
Metric Conversion .................................................................................................................... xii
!
Electromagnetic Compatibility (EMC) Compliance ............................................................... xii
!
EN55022 –1998 Compliance ................................................................................................... xiii
!
EN55082-1 – 1997 Compliance ............................................................................................... xiii
!
Federal Communications Commission (FCC) ......................................................................... xiii
!
Safety Compliance ..................................................................................................................... xiii !
EN 60950 ................................................................................................................................. xiii
!
European Low Voltage Directive (LVD) ................................................................................ xiii
!
Warranty Policy ......................................................................................................................... xiv
!
Limitations of Warranty ........................................................................................................... xiv
!
Exclusive Remedies .................................................................................................................. xv
!
Customer Support ...................................................................................................................... xvi
!
Online Customer Support ........................................................................................................ xvi
!
CHAPTER 1.
!
INTRODUCTION ................................................................................ 1–1
!
1.1
!
Overview ........................................................................................................................ 1–1
!
1.2
!
Features .......................................................................................................................... 1–2 !
1.2.1
!
Physical Configuration................................................................................................ 1–2
!
iii
UT-4500-A Series Upconverters
Table of Contents
Revision 0
MN-UT4500A
1.2.2
!
Dimensional Envelope ................................................................................................ 1–3
!
1.2.3
!
Front Panel .................................................................................................................. 1–4
!
1.2.4
!
Rear Panel ................................................................................................................... 1–4 !
1.3
!
Theory of Operation ..................................................................................................... 1–5 !
1.3.1
!
Applications ................................................................................................................ 1–5
!
1.3.2
!
RF Signal Conversion ................................................................................................. 1–6
!
1.3.3
!
Monitor & Control ...................................................................................................... 1–7 !
1.3.4
!
Installation, Operation and Maintenance .................................................................... 1–7
!
1.4
!
Summary of Specifications ........................................................................................... 1–8
!
1.4.1
!
UT-4505-A C-Band Upconverter ............................................................................... 1–8 !
1.4.2
!
UT-4505/E-A, /F-A /G-A, /H-A, /J-A Upconverters ................................................ 1–10
!
1.4.3
!
UT-4505/I-A, /M-A Upconverters ............................................................................ 1–12
!
1.4.4
!
UT-4514-A, /C-A, /D-A, /E-A, /F-A Upconverters .................................................. 1–14 !
1.4.5
!
UT-4518-A, /E-A Upconverters ............................................................................... 1–16
!
CHAPTER 2.
!
INSTALLATION ................................................................................. 2–1
!
2.1
!
Unpacking and Inspection ............................................................................................ 2–1
!
2.2
!
Installation ..................................................................................................................... 2–2 !
2.2.1
!
Standard Rack Mount Installation .............................................................................. 2–2
!
2.2.2
!
Installation using Optional Rear-Mounting Support Brackets .................................... 2–3
!
2.2.3
!
Installation Using Optional Bearingless Rack Slide Sets ........................................... 2–4 !
2.3
!
Connect Prime Power Connection .............................................................................. 2–5 !
2.4
!
Connect External Cables .............................................................................................. 2–5
!
CHAPTER 3.
!
REAR PANEL CONNECTORS ......................................................... 3–1
!
3.1
!
Rear Panel Overview .................................................................................................... 3–1 !
3.2
!
UT-4500-A External Connectors ................................................................................. 3–2
!
3.2.1
!
Chassis-mounted Connectors ...................................................................................... 3–2
!
3.2.1.1
!
IEC Line Input (AC Power) Connector .............................................................. 3–2
!
3.2.1.2
!
DC Power Connector (Optional) ........................................................................ 3–3
!
3.2.1.3
!
J2A | REF IN, External Reference Input Connector (BNC-F) ........................... 3–3
!
3.2.1.4
!
J2B | REF OUT, External Reference Output Connector (BNC-F) ..................... 3–3 !
3.2.1.5
!
100BASE-TX Ethernet M&C Port (RJ-45) ........................................................ 3–4
!
3.2.1.6
!
P1 RELAY, Summary Fault Output Connector (DB-9F) ................................... 3–4
!
3.2.1.7
!
J1 COM1 EIA-485/232 Interface Connector (DB-9F) ....................................... 3–5 !
3.2.1.8
!
Chassis Ground Connector ................................................................................. 3–5
!
3.2.2
!
Module-mounted Connectors ...................................................................................... 3–6
!
3.2.2.1
!
J3 HSB (High Speed Bus) Connector (DB-25F) ................................................ 3–7 !
3.2.2.2
!
Switch Module IF, RF, and Loop Connectors .................................................... 3–8
!
iv
UT-4500-A Series Upconverters
Table of Contents
Revision 0
MN-UT4500A
3.3
!
Cable Connections ........................................................................................................ 3–9 !
3.3.1
!
Cable Connections – Standalone (Non-Redundant) Operation ................................ 3–10
!
3.3.2
!
Cable Connections – Redundant System Operation ................................................. 3–10 !
CHAPTER 4.
!
FLASH UPGRADING ........................................................................ 4–1
!
4.1
!
Introduction ................................................................................................................... 4–1
!
4.2
!
About Firmware Files, Naming, Versions and Formats ........................................... 4–2
!
4.3
!
Ethernet FTP Upload Procedure ................................................................................. 4–3 !
CHAPTER 5.
!
FRONT PANEL OPERATION ........................................................... 5–1
!
5.1
!
Introduction ................................................................................................................... 5–1
!
5.1.1
!
Switch Power On (Rear Panel) ................................................................................... 5–2 !
5.1.2
!
LED Indicators ............................................................................................................ 5–2
!
5.1.3
!
Keypad ........................................................................................................................ 5–3
!
5.1.4
!
Vacuum Fluorescent Display (VFD) .......................................................................... 5–3 !
5.2
!
Opening Screen ............................................................................................................. 5–4 !
5.3
!
Main Menu .................................................................................................................... 5–4
!
5.3.1
!
CONFIG (Configuration)............................................................................................ 5–5
!
5.3.1.1
!
CONFIG: OUTPUT ............................................................................................ 5–5 !
5.3.1.2
!
CONFIG: REMOTE (Remote Control) .............................................................. 5–6
!
5.3.1.3
!
CONFIG: REDUNDANCY................................................................................ 5–9
!
5.3.1.4
!
CONFIG: FAULTRECOVERY ....................................................................... 5–11 !
5.3.1.5
!
CONFIG: COLDSTART .................................................................................. 5–11
!
5.3.2
!
MONITOR ................................................................................................................ 5–12
!
5.3.3
!
FAULTS ................................................................................................................... 5–12 !
5.3.3.1
!
FAULTS: CURRENT ....................................................................................... 5–12
!
5.3.3.2
!
FAULTS: STORED (Stored Faults Log) ......................................................... 5–13
!
5.3.4
!
PRE-SELECTS ......................................................................................................... 5–13
!
5.3.4.1
!
PRE-SELECTS: LOAD .................................................................................... 5–14
!
5.3.4.2
!
PRE-SELECTS: PROGRAM ........................................................................... 5–14
!
5.3.4.3
!
PRE-SELECTS: CLEAR .................................................................................. 5–14
!
5.3.5
!
UTILITY ................................................................................................................... 5–15 !
5.3.5.1
!
UTILITY: TIME (Real-Time Clock) ................................................................ 5–15
!
5.3.5.2
!
UTILITY : DISP (VFD Display) ...................................................................... 5–16
!
5.3.5.3
!
UTILITY: AID (Application Identification String) .......................................... 5–16 !
5.3.5.4
!
UTILITY: REFOSC (Reference Oscillator Adjustment) ................................. 5–16
!
5.3.5.5
!
UTILITY: SLOPE ............................................................................................ 5–16
!
5.3.5.6
!
UTILITY: LAMP-TEST ................................................................................... 5–17 !
5.3.5.7
!
UTILITY: FIRMWARE ................................................................................... 5–17
!
v
UT-4500-A Series Upconverters
Table of Contents
Revision 0
MN-UT4500A
CHAPTER 6.
!
ETHERNET MANAGEMENT ............................................................. 6–1
!
6.1
!
Overview ........................................................................................................................ 6–1
!
6.2
!
Ethernet Management Interface Protocols ................................................................ 6–1
!
6.3
!
SNMP Interface ............................................................................................................. 6–1 !
6.3.1
!
Management Information Base (MIB) Files ............................................................... 6–2
!
6.3.2
!
SNMP Community Strings ......................................................................................... 6–2
!
6.3.3
!
SNMP Traps................................................................................................................ 6–3 !
6.4
!
Telnet Interface ............................................................................................................. 6–4
!
6.4.1
!
HyperTerminal as Telnet Client .................................................................................. 6–4
!
APPENDIX A.
!
REMOTE CONTROL ....................................................................... A–1 !
A.1
!
Introduction .................................................................................................................. A–1 !
A.2
!
Communication Interfaces .......................................................................................... A–1
!
A.2.1
!
TIA/EIA-485 (RS-485) .......................................................................................... A–1 !
A.2.2
!
TIA/EIA-232 (RS-232) .......................................................................................... A–2
!
A.2.3
!
Ethernet (100BASE-TX) ....................................................................................... A–2
!
A.3
!
Access Methods ............................................................................................................ A–2
!
A.3.1
!
Direct Access ......................................................................................................... A–2 !
A.3.2
!
Indirect Access ....................................................................................................... A–3
!
A.4
!
Addresses ...................................................................................................................... A–3
!
A.4.1
!
Physical Address .................................................................................................... A–3 !
A.4.2
!
Virtual Address ...................................................................................................... A–3
!
A.4.3
!
IP Address .............................................................................................................. A–4
!
A.5
!
Basic Protocol ............................................................................................................... A–4
!
A.5.1
!
Transmission Mode ................................................................................................ A–4
!
A.5.2
!
Baud Rate ............................................................................................................... A–4
!
A.5.3
!
Asynchronous Character Format ........................................................................... A–4
!
A.5.4
!
Character Set .......................................................................................................... A–4
!
A.5.5
!
Response Timeout .................................................................................................. A–4
!
A.5.6
!
Bus Inactivity Requirement ................................................................................... A–5
!
A.6
!
Message Structure ........................................................................................................ A–5 !
A.6.1
!
Start Character ....................................................................................................... A–5
!
A.6.2
!
Device Address ...................................................................................................... A–5
!
A.6.3
!
Command ............................................................................................................... A–5 !
A.6.4
!
Confirmation Response .......................................................................................... A–6
!
A.6.5
!
Error Response ....................................................................................................... A–6
!
A.6.6
!
End of Message ...................................................................................................... A–6 !
vi
UT-4500-A Series Upconverters
Table of Contents
Revision 0
MN-UT4500A
A.6.6.1
!
Command Ending .............................................................................................. A–6
!
A.6.6.2
!
Response Ending ................................................................................................ A–6
!
A.7
!
Command / Response Pairs......................................................................................... A–7
!
A.7.1
!
Utility Commands .................................................................................................. A–7
!
A.7.1.1
!
Time ................................................................................................................... A–7
!
A.7.1.2
!
Date .................................................................................................................... A–7
!
A.7.1.3
!
Local / Remote Status ........................................................................................ A–7 !
A.7.1.4
!
Media Access Control (MAC) Address ............................................................. A–8
!
A.7.1.5
!
IP Address .......................................................................................................... A–8
!
A.7.1.6
!
IP Gateway ......................................................................................................... A–8 !
A.7.1.7
!
Physical Address ................................................................................................ A–9
!
A.7.1.8
!
Baud Rate ........................................................................................................... A–9
!
A.7.1.9
!
LCD Contrast ..................................................................................................... A–9 !
A.7.1.10
!
LCD Brightness ............................................................................................. A–9
!
A.7.1.11
!
Screen Saver Mode ...................................................................................... A–10
!
A.7.1.12
!
Screen Saver Timeout .................................................................................. A–10
!
A.7.1.13
!
VFD Brightness ........................................................................................... A–10 !
A.7.1.14
!
Reference Oscillator Tuning ........................................................................ A–10
!
A.7.1.15
!
Converter Slope Adjustment ........................................................................ A–11
!
A.7.1.16
!
Equipment Type ........................................................................................... A–11 !
A.7.1.17
!
Part Number ................................................................................................. A–11
!
A.7.1.18
!
Legacy Firmware Information ..................................................................... A–11
!
A.7.1.19
!
Firmware Information .................................................................................. A–12 !
A.7.1.20
!
Firmware Image ........................................................................................... A–12
!
A.7.1.21
!
Application Identification ............................................................................ A–12
!
A.7.1.22
!
Force Reboot ................................................................................................ A–13
!
A.7.2
!
Configuration Commands .................................................................................... A–13
!
A.7.2.1
!
Frequency ......................................................................................................... A–13
!
A.7.2.2
!
Attenuator ........................................................................................................ A–13
!
A.7.2.3
!
Cold Start ......................................................................................................... A–14 !
A.7.2.4
!
Mute ................................................................................................................. A–14
!
A.7.2.5
!
Carrier Mute Mode .......................................................................................... A–14
!
A.7.2.6
!
Redundant Mute Mode .................................................................................... A–14 !
A.7.2.7
!
Auto Fault Recovery ........................................................................................ A–15
!
A.7.2.8
!
Program Preset ................................................................................................. A–15
!
A.7.2.9
!
Display All Presets ........................................................................................... A–15 !
A.7.2.10
!
Clear Preset Configuration ........................................................................... A–16
!
A.7.2.11
!
Select Preset Configuration.......................................................................... A–16
!
A.7.3
!
Modes ................................................................................................................... A–16
!
A.7.3.1
!
Redundant Mode .............................................................................................. A–16 !
A.7.3.2
!
Automatic/Manual Mode ................................................................................. A–17
!
A.7.3.3
!
Backup Mode ................................................................................................... A–17
!
A.7.4
!
Status Commands................................................................................................. A–18 !
A.7.4.1
!
Configuration Status ........................................................................................ A–18
!
A.7.4.2
!
Maintenance Status .......................................................................................... A–18
!
A.7.4.3
!
Utility Status .................................................................................................... A–19 !
vii
UT-4500-A Series Upconverters
Table of Contents
Revision 0
MN-UT4500A
A.7.4.4
!
Alarm Status..................................................................................................... A–19
!
A.7.4.5
!
Summary Alarm Status .................................................................................... A–19
!
A.7.4.6
!
Terminal Status Change ................................................................................... A–19 !
A.7.4.7
!
Packed Configuration Status ............................................................................ A–20
!
A.7.4.8
!
Packed Maintenance Status .............................................................................. A–20
!
A.7.4.9
!
Packed Utility Status ........................................................................................ A–21
!
A.7.4.10
!
Packed Alarm Status .................................................................................... A–21 !
A.7.5
!
Stored Alarms ...................................................................................................... A–22
!
A.7.5.1
!
Total Stored Alarms ......................................................................................... A–22
!
A.7.5.2
!
Clear All Stored Alarms ................................................................................... A–22 !
A.7.5.3
!
List All Alarms ................................................................................................ A–22
!
A.7.6
!
Error Processing ................................................................................................... A–23
!
A.7.6.1
!
General Errors .................................................................................................. A–23 !
A.7.6.2
!
Configuration Errors ........................................................................................ A–23
!
A.7.6.3
!
Mode Errors ..................................................................................................... A–23
!
A.7.6.4
!
Time-Outs ........................................................................................................ A–23
!
A.7.7
!
Command Summaries .......................................................................................... A–24 !
A.7.8
!
User Remote Command Summary ...................................................................... A–24
!
APPENDIX B.
!
REDUNDANT SYSTEM OPERATION ............................................ B–1
!
B.1
!
Introduction to Redundancy Operation ..................................................................... B–1 !
B.2
!
Backup Upconverter ..................................................................................................... B–1 !
B.2.1
!
High Speed Bus (HSB) ........................................................................................... B–1
!
B.2.2
!
Detachable Modules ................................................................................................ B–2 !
B.2.2.1
!
Upconverter Switching ....................................................................................... B–2
!
B.3
!
Redundant Configurations ........................................................................................... B–2
!
B.4
!
Redundant System Configuration ............................................................................... B–8
!
B.4.1
!
Initial Configuration ................................................................................................ B–8
!
B.4.2
!
Automatic Configuration Verification .................................................................... B–9
!
B.4.3
!
Manual Configuration and Verification ................................................................ B–11
!
B.4.4
!
Offset Adjustment ................................................................................................. B–13 !
B.4.5
!
Redundancy Systems – Upconverter Removal and Replacement ........................ B–13
!
APPENDIX C.
!
MAINTENANCE AND TROUBLESHOOTING ................................. C–1
!
C.1
!
Overview ....................................................................................................................... C–1 !
C.2
!
Maintenance Testing .................................................................................................... C–2 !
C.2.1
!
Test Point Samples .................................................................................................. C–2
!
C.2.2
!
Troubleshooting ...................................................................................................... C–2 !
C.2.3
!
Upconverter Faults .................................................................................................. C–2
!
C.2.3.1
!
Prime Power ........................................................................................................ C–2
!
C.2.3.2
!
DC Power Supply Module .................................................................................. C–2
!
viii
UT-4500-A Series Upconverters
Table of Contents
Revision 0
MN-UT4500A
C.2.3.3
!
RF Converter Module ......................................................................................... C–3
!
C.2.3.4
!
Synthesizer Sum Loop Module ........................................................................... C–3
!
C.2.3.5
!
Synthesizer Fine Step Module ............................................................................ C–3 !
C.2.3.6
!
Reference Oscillator Module .............................................................................. C–3
!
C.2.3.7
!
Temperature Fault ............................................................................................... C–3
!
C.2.4
!
Converter I/O Modules ........................................................................................... C–4
!
C.3
!
Spares ............................................................................................................................ C–4 !
TABLES
Table 3-1. UT-4500-A Rear Panel External Connections ......................................................... 3–2
!
Table 3-2. Ethernet M&C Interface Connector Pinout ............................................................... 3–4 !
Table 3-3. P1 – Summary Fault Connector Pinout .................................................................... 3–4
!
Table 3-4. J1 – 2-Wire EIA-485 Pinout ...................................................................................... 3–5
!
Table 3-5. J1 – 4-Wire EIA-485 Pinout ...................................................................................... 3–5
!
Table 3-6. J1 – EIA-232C Pinout ............................................................................................... 3–5 !
Table 3-7. J3 HSB Interface Connector Pinout .......................................................................... 3–7
!
Table 3-8. DT-4500-A and UT-4500-A Available Switch Module Assemblies ........................ 3–8
!
ix
UT-4500-A Series Upconverters
Table of Contents
Revision 0
MN-UT4500A
FIGURES
Figure 1-1. UT-4500-A Series Upconverters (UT-4505-A shown) ............................................ 1–1
Figure 1-2. UT-4500-A Series Upconverter Physical Configuration ......................................... 1–2
Figure 1-3. UT-4500-A Series Upconverter Dimensional Envelope .......................................... 1–3
Figure 1-4. UT-4500-A Series Upconverter Front Panel ............................................................ 1–4
Figure 1-5. UT-4500-A Series Upconverter Rear Panel ............................................................. 1–4
Figure 1-6. Typical Functional Block Diagram (UT-4512-A shown) ........................................ 1–6
Figure 2-1. Standard Rack Cabinet Installation .......................................................................... 2–2
Figure 2-2. Optional Rear-Mounting Support Brackets Installation .......................................... 2–3
Figure 2-3. Optional Bearingless Rack Slide Installation (FP/SL000X) .................................... 2–4
Figure 3-1. UT-4500-A Rear Panel ............................................................................................ 3–1
Figure 3-2. IOM, RSM, and TSM Switch Modules ................................................................... 3–6
Figure 3-3. UT-4500-A Rear Panel (UT-4505-A with Receive Switch Module [RSM-XX]
Shown) ................................................................................................................................ 3–9
Figure 3-4. Standalone (Non-Redundant) Upconverter Configuration .................................... 3–10
Figure 3-5. Standalone (Non-Redundant) Upconverter Configuration with Transmit Switch
Module (TSM-XX) Installed ............................................................................................ 3–11
Figure 4-1. Flash Upgrade via Internet ....................................................................................... 4–1
Figure 5-1. UT-4500-A Front and Rear Panel Views ................................................................. 5–1
Figure B-1. 1:1 Redundant Configuration –Single Source IF Input with IOM-XX and TSM-XX
Installed ............................................................................................................................... B–3
Figure B-2. 1:1 Redundant Configuration Diagram – Single Source RF Input with IOM-XX and
TSM-XX Installed .............................................................................................................. B–3
Figure B-3. 1:1 Redundant Configuration Diagram – Single Source RF Input with IOM-XX and
TSEQM-XX Installed ........................................................................................................ B–4
Figure B-4. TSEQM Connection Locations ............................................................................... B–4
Figure B-5. 1:1 Redundant Configuration - Dual Source IF Input ............................................. B–5
Figure B-6. 1:1 Redundant Configuration Diagram – Dual Source IF Input with IOM-XX and
TSM-XX Installed .............................................................................................................. B–5
Figure B-7. 1:N Redundant Configuration with IOM-XX and TSM-XX Installed ................... B–6
Figure B-8. 1:N Redundant Configuration Diagram with IOM-XX and TSM-XX Installed .... B–7
Figure B-9. Front Panel Displays................................................................................................ B–8
Figure B-10. System in Auto Redundant Mode .......................................................................... B–9
Figure B-11. Backup of Converter #1....................................................................................... B–10
Figure B-12. Converter #1 in MANUAL, Others in AUTO ..................................................... B–11
Figure B-13. Forced Backup of Converter #1 .......................................................................... B–12
Figure C-1. Upconverter Signal and Interconnecting Cable Diagram (with Transmit Switch
Module [TSM]) ................................................................................................................... C–1 x
PREFACE
About this Manual
This manual provides installation and operation information for the Comtech EF Data’s
UT-4500-A Series Upconverters. This is a technical document intended for earth station engineers, technicians, and operators responsible for the operation and maintenance of the
UT-4500-A family of products.
Disclaimer
Comtech EF Data has reviewed this manual thoroughly to provide an easy-to-use guide to your equipment. All statements, technical information, and recommendations in this manual and in any guides or related documents are believed reliable, but the accuracy and completeness thereof are not guaranteed or warranted, and they are not intended to be, nor should they be understood to be, representations or warranties concerning the products described. Further, Comtech EF Data reserves the right to make changes in the specifications of the products described in this manual at any time without notice and without obligation to notify any person of such changes.
If you have any questions regarding the equipment or the information in this manual, please contact the Comtech EF Data Customer Support Department.
Reporting Comments or Suggestions Concerning this Manual
Comments and suggestions regarding the content and design of this manual are appreciated. To submit comments, please contact the Comtech EF Data Technical Publications department:
UT-4500-A Series Upconverters
Preface
Conventions and References
Cautions and Warnings
Revision 0
MN-UT4500A
IMPORTANT
IMPORTANT or NOTE indicates a statement that is associated with either
information critical for proper equipment function or the task being performed.
CAUTION indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. CAUTION may also be used to indicate other unsafe
practices or risks of property damage.
WARNING indicates a potentially hazardous situation that, if not avoided, could
result in death or serious injury.
Recommended Standard Designations
The Recommended Standard (RS) designation has been superseded by the new designation of the
Electronic Industries Association (EIA). References to the old designation may be shown only when depicting actual text displayed on the screen of the unit (RS-232, RS-485, etc.). All other references in the manual will be shown with the EIA designation.
Trademarks
Windows is a trademark of the Microsoft Corporation. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Metric Conversion
Metric conversion information is located on the inside back cover of this manual. This information is provided to assist the operator in cross-referencing non-Metric to Metric conversions.
The User should carefully review the information that follows.
IMPORTANT
Electromagnetic Compatibility (EMC) Compliance
This is a Class A product. In a domestic environment, it may cause radio interference that requires the user to take adequate protection measures. xii
UT-4500-A Series Upconverters
Preface
Revision 0
MN-UT4500A
EN55022 –1998 Compliance
This equipment meets the radio disturbance characteristic specifications for information technology equipment as defined per EN55022 1998.
EN55082-1 – 1997 Compliance
This equipment meets the EMC/generic immunity standard as defined per EN55082-1 1997.
Federal Communications Commission (FCC)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference; in which case, users are required to correct the interference at their own expense.
To ensure compliance, properly shielded cables for DATA I/O must be used.
More specifically, these cables must be shielded from end to end, ensuring a continuous shield.
Safety Compliance
EN 60950
The UT-4500-A Series Upconverters have been shown to comply with safety standard EN 60950
Safety of Information Technology Equipment including Electrical Business Machines.
Applicable testing is routinely performed as a condition of manufacturing on all units to ensure compliance with safety requirements of EN 60950.
European Low Voltage Directive (LVD)
The following information is applicable for the European Low Voltage Directive (2006/95/EC):
Symbol Description
<HAR> Type of power cord required for use in the European Community.
!
CAUTION: Double-pole/Neutral Fusing
ACHTUNG: Zweipolige bzw. Neutralleiter-Sicherung xiii
UT-4500-A Series Upconverters
Preface
Revision 0
MN-UT4500A
Symbol
International Symbols
Definition Symbol Definition
Alternating Current Protective Earth
Fuse Chassis Ground
IMPORTANT
For additional symbols, refer to Cautions and Warnings listed earlier in this
Preface.
Warranty Policy
Comtech EF Data products are warranted against defects in material and workmanship for a specific period from the date of shipment, and this period varies by product. In most cases, the warranty period is two years. During the warranty period, Comtech EF Data will, at its option, repair or replace products that prove to be defective. Repairs are warranted for the remainder of the original warranty or a 90 day extended warranty, whichever is longer.
Contact Comtech EF Data for the warranty period specific to the product purchased.
For equipment under warranty, the owner is responsible for freight to Comtech EF Data and all related customs, taxes, tariffs, insurance, etc. Comtech EF Data is responsible for the freight charges only for return of the equipment from the factory to the owner. Comtech
EF Data will return the equipment by the same method (i.e., Air, Express, Surface) as the equipment was sent to Comtech EF Data.
All equipment returned for warranty repair must have a valid RMA number issued prior to return and be marked clearly on the return packaging. Comtech EF Data strongly recommends all equipment be returned in its original packaging.
Comtech EF Data Corporation’s obligations under this warranty are limited to repair or replacement of failed parts, and the return shipment to the buyer of the repaired or replaced parts.
Limitations of Warranty
The warranty does not apply to any part of a product that has been installed, altered, repaired, or misused in any way that, in the opinion of Comtech EF Data Corporation, would affect the reliability or detracts from the performance of any part of the product, or is damaged as the result of use in a way or with equipment that had not been previously approved by Comtech EF Data Corporation.
The warranty does not apply to any product or parts thereof where the serial number or the serial number of any of its parts has been altered, defaced, or removed. xiv
UT-4500-A Series Upconverters
Preface
Revision 0
MN-UT4500A
The warranty does not cover damage or loss incurred in transportation of the product.
The warranty does not cover replacement or repair necessitated by loss or damage from any cause beyond the control of Comtech EF Data Corporation, such as lightning or other natural and weather related events or wartime environments.
The warranty does not cover any labor involved in the removal and or reinstallation of warranted equipment or parts on site, or any labor required to diagnose the necessity for repair or replacement.
The warranty excludes any responsibility by Comtech EF Data Corporation for incidental or consequential damages arising from the use of the equipment or products, or for any inability to use them either separate from or in combination with any other equipment or products.
A fixed charge established for each product will be imposed for all equipment returned for warranty repair where Comtech EF Data Corporation cannot identify the cause of the reported failure.
Exclusive Remedies
Comtech EF Data Corporation’s warranty, as stated is in lieu of all other warranties, expressed, implied, or statutory, including those of merchantability and fitness for a particular purpose. The buyer shall pass on to any purchaser, lessee, or other user of
Comtech EF Data Corporation’s products, the aforementioned warranty, and shall indemnify and hold harmless Comtech EF Data Corporation from any claims or liability of such purchaser, lessee, or user based upon allegations that the buyer, its agents, or employees have made additional warranties or representations as to product preference or use.
The remedies provided herein are the buyer’s sole and exclusive remedies. Comtech EF
Data shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. xv
UT-4500-A Series Upconverters
Preface
Customer Support
Revision 0
MN-UT4500A
Refer to p. xiv in this Preface for information regarding this product’s Warranty Policy.
Contact the Comtech EF Data Customer Support Department for:
! Product support or training
! Reporting comments or suggestions concerning manuals
! Information on upgrading or returning a product
A Customer Support representative may be reached during normal business hours at:
Comtech EF Data
Attention: Customer Support Department
2114 West 7th Street
Tempe, Arizona 85281 USA
480.333.2200 (Main Comtech EF Data number)
480.333.4357 (Customer Support Desk)
480.333.2161 FAX
To return a Comtech EF Data product (in-warranty and out-of-warranty) for repair or replacement:
! Contact the Comtech EF Data Customer Support Department during normal business hours. Be prepared to supply the Customer Support representative with the model number, serial number, and a description of the problem.
!
!
!
Request a Return Material Authorization (RMA) number from the Comtech EF Data
Customer Support representative.
Pack the product in its original shipping carton/packaging to ensure that the product is not damaged during shipping.
Ship the product back to Comtech EF Data. (Shipping charges should be prepaid.)
Online Customer Support
An RMA number can be requested electronically by accessing Comtech EF Data’s online
Support page (www.comtechefdata.com/support.asp). From this page:
! Click the Service hyperlink, then read the Return Material Authorization section for detailed instructions on Comtech EF Data’s return procedures.
! Click [Send RMA Request] on the Support page or the RMA Request hyperlink provided in the Service | Return Material Authorization section; fill out the Billing Information,
Return Information, and Unit to be Returned sections completely, then click [Send email]
!
– or –
Send an e-mail providing this same detailed information to the Customer Support
Department at [email protected]. xvi
Chapter 1. INTRODUCTION
1.1 Overview
Figure 1-1. UT-4500-A Series Upconverters (UT-4505-A shown)
Comtech EF Data’s UT-4500-A Series Upconverters (Figure 1-1) are designed for the
transmission of SCPC, DAMA and TDMA signals in communication systems or satellite uplink data systems. The Upconverters can also be used in communications system applications with full transponder HDTV and analog TV.
The UT-4500-A Series Upconverter family of products comprises:
! UT-4505-A ! UT-4514-A ! UT-4518-A
! UT-4505/E-A
! UT-4505/F-A
! UT-4514/C-A
! UT-4514/D-A
! UT-4518/E-A
! UT-4505/G-A
! UT-4505/H-A
! UT-4514/E-A
! UT-4514/F-A
! UT-4505/I-A
! UT-4505/J-A
! UT-4505/M-A
Individual specifications for each model are included in this chapter.
1–1
UT-4500A Series Upconverters
Introduction
1.2 Features
Revision 0
MN-UT4500A
1.2.1 Physical Configuration
The UT-4500-A Series Upconverter’s 1RU-high (1.75”) 19-inch wide chassis is designed for rack mounting into a standard 19-inch (48.26 cm) equipment rack. Handles installed on the front panel facilitate ease of installation into and removal from the equipment rack. The unit may also be mounted into the rack using the provided slide mechanisms to allow service without removal from the rack.
Figure 1-2 depicts the isometric layout of the UT-4500-A with its top cover removed. Major
chassis components are shown here. The major module assemblies are:
! Signal Path Module
! Step Loop Module
! Monitor & Control Assembly
! Transmit Switch Module (not shown – installs into rear chassis slot)
! Reference Oscillator Assembly
! Sum Loop Module
! Power Supply Assembly
Figure 1-2. UT-4500-A Series Upconverter Physical Configuration
1–2
UT-4500A Series Upconverters
Introduction
1.2.2 Dimensional Envelope
Dimensions are shown in both inches and centimeters.
17.00
(432)
Revision 0
MN-UT4500A
22.00
(55.9)
1.75”
(4.45)
SAMPLE
RF IF
POWER ON
TRANSMIT
REMOTE
STATUS
ON LINE
FAULT
STORED FAULT
ENT
CLR
18.25
(46.35)
19.0
(48.3)
Figure 1-3. UT-4500-A Series Upconverter Dimensional Envelope
1–3
UT-4500A Series Upconverters
Introduction
1.2.3 Front Panel
Revision 0
MN-UT4500A
Figure 1-4. UT-4500-A Series Upconverter Front Panel
Figure 1-4 shows the typical front panel of the UT-4500-A Series Upconverters. This example
depicts a UT-4505-A Upconverter. All operator controls, indicators and displays for local and remote operation are located on the front panel of the UT-4500-A. The front panel features (from left):
! Two Test Point Sample Ports – The test point connections are used for monitoring the
RF input and the IF output. An SMA connector is provided for the RF output, and a
BNC connector is provided for the IF input. There is also an optional RF LO monitor available.
! Six Light-Emitting Diode (LED) Indicators – The LEDs indicate, in a summary fashion, the status of the unit.
! Vacuum Fluorescent Display (VFD) – The VFD is an active display showing two lines of 24 characters each. Each configuration function, or operating mode, is shown on the display when the operator enters a command using the keypad.
! Six-button Keypad – The keypad comprises six individual keyswitches. They have a positive ‘click’ action, which provides tactile feedback.
1.2.4 Rear Panel
Figure 1-5. UT-4500-A Series Upconverter Rear Panel
Figure 1-5 shows the typical rear panel of the UT-4500-A Series Upconverters. This example
depicts a UT-4505-A Upconverter with Transmit Switch Module (TSM) installled. The rear panel features (from left):
! Prime Power Switch – The on/off prime power switch is located on the rear of the chassis adjacent to the prime power input connector. The power switch contains a filter and dual fuse. The dual fuse is rated for 2 Amps.
The UT-4500-A is provided with a six-foot AC power cord.
! Exhaust Fan – The internally mounted exhaust fan vents through the rear panel for chassis cooling.
1–4
UT-4500A Series Upconverters
Introduction
Revision 0
MN-UT4500A
! External Interface Connectors – Connectors are provided for operational communications, connection of external reference, redundant operation, and remote monitor and control of the UT-4500-A.
1.3 Theory of Operation
1.3.1 Applications
The upconverter operates over the RF frequency range with a typical gain of 35 dB. The RF output level is +10 dBm at 1 dB compression allowing the capability for longer cable runs to compensate for splitting networks without adding options such as external line amplifiers.
The phase noise performance exceeds the Intelsat phase noise mask for IBS and IDR services by more than 9 dB. This allows high capacity earth stations to add more demodulators and still meet transmission standards. The close-in phase noise is also very low. This makes the upconverter ideal for low bit rate digital circuits such as used in DAMA hub earth stations.
A selectable EIA-232C or EIA-485 remote control serial communications connector interface is provided on the rear panel of the upconverter. All configuration control, status retrieval and adjustments are available as ASCII commands through the serial interface, or as local operator input command to the upconverter.
A detachable Input/Output Module (IOM) can be mounted in the rear of the upconverter chassis for switching the RF output for single thread operations, or for testing the output of the unit. The connectors for the IOM are located on the rear panel.
In applications where converters are "Daisy Chained" together to provide distributed online protection switching to a backUpconverter, the IOM is replaced with a detachable Transmit
Switch Module (TSM). The TSM contains RF and IF transfer switches. Type N connectors are provided for the RF loop, and 50 or 75 ohms BNC connectors are provided for the IF loop.
The "Daisy Chain" configuration is designed to chain the IF input and RF output of up to twelve
(12) online converters together through TSM's terminating in a backUpconverter. When a fault occurs in an online upconverter, the TSM in the upconverter with the fault is commanded to switch to the backUpconverter.
The backUpconverter performs the fault detection, self-reconfiguration and the logical switching functions. If the backUpconverter has a fault, it will not attempt to perform the protectionswitching task. If the backUpconverter does not have a fault, it will assume the frequency and attenuation of the faulted online upconverter, and compensate for the chain losses.
The backUpconverter in the "Daisy Chain" communicates with the online converters through a high speed (data interface) bus (HSB). When faults are detected, the backUpconverter reconfigures itself to replace the online upconverter with the fault. The backUpconverter also uses the HSB to monitor configuration changes made to the online converters by either remote control or front panel command inputs.
1–5
UT-4500A Series Upconverters
Introduction
Revision 0
MN-UT4500A
Changes in frequency, attenuation or polarity are entered into the backup table as they are made, as well as information from new online units. The HSB does not interfere with the remote control communications link for access to any of the converters in the "Daisy Chain".
1.3.2 RF Signal Conversion
As a typical example of the RF signal processing, in the Model UT-4514-A Upconverter, the 70
MHz IF input is mixed in the first mixer with a 1150 MHz IFLO signal. The IFLO is locked to a
5/10 MHz reference oscillator. The first mixer is located in the Signal Path Assembly.
The intermediate IF is 1220 MHz which is mixed in the second stage mixer with 12780 to 13280
MHz synthesizer signal to provide an RF output frequency of 14000 to 1451X MHz in 125 KHz fine tuning steps. The synthesizer is also locked to the 5/10 MHz reference oscillator. The second mixer is located in the upconverter Signal Path Module, and the synthesizer consists of the
Coarse/Fine Step Module and Sum Loop Module.
Figure 1-6 depicts the operational schematic for a typical UT-4500-A Series Upconverter in
single thread (standalone) applications. For more information about the UT-4500-A’s use in redundant applications, refer to Appendix B. REDUNDANT SYSTEM OPERATION.
Figure 1-6. Typical Functional Block Diagram (UT-4512-A shown)
1–6
UT-4500A Series Upconverters
Introduction
Revision 0
MN-UT4500A
1.3.3 Monitor & Control
The Monitor & Control Assembly is designed to monitor the functions of the upconverter, and provide the control for remote and local command inputs to the upconverter.
Remote control inputs are provided through the EIA-232C or EIA-485 communications port on the rear of the panel, or by local operator inputs through the keypad on the front panel.
Local operator input commands and the status of the upconverter are displayed on the front panel
Vacuum Fluorescent Display (VFD) on the front panel.
A upconverter fault is indicated by the LED indicator on the front panel. Specific fault conditions are displayed on the VFD through local keypad input commands.
1.3.4 Installation, Operation and Maintenance
Refer to Chapter 2. INSTALLATION for rack installation and mounting instructions.
Refer to Chapter 5. FRONT PANEL OPERATION for local operating instructions and procedures.
Refer to Appendix A. REMOTE CONTROL for remote control operating instructions and procedures.
Refer to Appendix B. REDUNDANT SYSTEM OPERATION for redundant system operating instructions and procedures.
Refer to Appendix C. MAINTENANCE AND TROUBLESHOOTING for maintenance and troubleshooting procedures.
1–7
UT-4500A Series Upconverters
Introduction
1.4 Summary of Specifications
*Note: Contact Comtech EF Data with specific requirements.
1.4.1 UT-4505-A C-Band Upconverter
Characteristic Specification
Frequency Range UT-4505-A
Conversion
Step Size
IF Input
RF Output
5845-6425 MHz
Dual, No Inversion
125 kHz standard, 1kHz optional
Preset Channels 32 Frequencies and Gains
Stability over Time ± 1 x 10 -9 /Day
Stability over Step ± 1 x 10 -8 0-50°C (32-122°F)
Noise Figure 12 dB Maximum at 0 dB Attenuation
Level
Range
-35 dBm Typical
+20 dBm at 1 dB Compression
Impedance
Return Loss
Output Level
Intermodulation
Carrier Mute
50 " or 75"
23 dB min. with IO Module or Switch Module
+17 dBm at 1 dB Compression
-50 dBc @ 0 dBm Output SCL
-70 dBc
Non-carrier Spurious -80 dBm
Carrier Spurious -65 dBc @ 0 dBm Output
Transfer
External Reference
Group Delay
Phase Noise
AM to PM
Return Loss
Impedance
Gain
Gain Adjust
Gain Stability
Ripple
Slope
IF Bandwidth
0.1
o . / dB at –5 dBm Out
20 dB Minimum with IO Module
18 dB Minimum with Switch Module
50 "
35 dB ± 2 dB
0-25 in 0.25 dB Steps
0.1 dB Steps Optional
± 0.25 dB/Day
70MHz IFCF: ±0.25 dB (±18 MHz), optional ±20 MHz (see *Note)
140 MHz IFCF: 0.75 dB (±36 MHz), optional ±40 MHz (see *Note)
0.05 dB/MHz
36 or 72 MHz, (optional 40 or 80 MHz – see *Note)
Input 5 or 10 MHz @ +3 dBm
Optional 10 MHz Rear Panel Reference Output
Linear Group Delay 0.03 ns/MHz
Parabolic Delay 0.01 ns/MHz 2
Group Delay Ripple 1.0 ns Peak-to-Peak
Parameter Limit (dBc/Hz)
100 Hz
1 kHz
10 kHz
-80
-89
-95
Typical (dBc/Hz)
-83
-92
-97
100 kHz
1 MHz
Remote Control (Rear Panel)
-105
-120
Comm Port EIA-485 or EIA-232
-109
-124
Revision 0
MN-UT4500A
1–8
UT-4500A Series Upconverters
Introduction
Characteristic Specification
LED Indicators
(Front Panel)
Test Points
(Front Panel)
Power
Environmental
Physical
MTBF
Summary Alarm Relay Closure
Power On
Transmit
Remote
On Line
Fault
Stored Fault
RF Sample
IF Sample
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
Type ‘SMA’ Connector, -20 dBc Nominal
Type ‘BNC’ Connector, -20 dBc Nominal
Optional L.O. Sample
Voltage 90-250 VAC Autoranging
Frequency 47-63 Hz
Dissipation
Power Option
Temperature
60 Watts
-48 VDC
0-50°C (32-122° F)
Altitude
Humidity
Width
10,000 Feet MSL
0-95% Relative
19 Inches (48.26 cm)
Height 1RU 1.75 Inches (4.44 cm)
Depth
Weight
22 Inches (55.88 cm)
15 Pounds (7.00 kg)
49,740 hrs. (calculated)
>100,000 hrs. (field experience)
Form C
Revision 0
MN-UT4500A
1–9
UT-4500A Series Upconverters
Introduction
Revision 0
MN-UT4500A
1.4.2 UT-4505/E-A, /F-A /G-A, /H-A, /J-A Upconverters
Characteristic
RF Output
Specification
Frequency Range UT-4505-A
UT-4505/E-A
UT-4505/F-A
UT-4505/G-A
UT-4505/H-A
UT-4505/J-A
Conversion
Step Size
IF Input
See Sect. 1.4.1
6725-7025 MHz
6425-6725 MHz
5925-6725 MHz
5850-6650 MHz
7025-7075 MHz
Dual, No Inversion
125 kHz standard, 1kHz optional
Preset Channels 32 Frequencies and Gains
Stability over Time ± 1 x 10 -9 /Day
Stability over Temp ± 1 x 10 -8 0-50°C (32-122°F)
Noise Figure 11 dB Maximum at 0 dB Attenuation
Level
Range
Impedance
-45 dBm Typical
52 to 88 or 104 to 176 MHz (optional 50-80 MHz or 100-180 MHz – see *Note)
50 " or 75"
Return Loss
Output Level
Intermodulation
Carrier Mute
23 dB min. with IO Module of Switch Module
+17 dBm at 1 dB Compression
-60 dBc @ 0 dBm Output SCL
-70 dBc
Non-carrier Spurious -80 dBm
Carrier Spurious -65 dBc @ 0 dBm Output
AM to PM
Return Loss
Impedance
0.1
o . / dB at –5 dBm Out
20 dB Minimum with IO Module
18 dB Minimum with Switch Module
50 "
Transfer
Slope
External Reference
Group Delay
Phase Noise
Gain
Gain Adjust
Gain Stability
Ripple
Slope
IF Bandwidth
35 dB ± 2 dB
0-25 in 0.25 dB Steps
0.1 dB Steps Optional
± 0.25 dB/Day
70MHz IFCF: ±0.25 dB (±18 MHz), optional ±20 MHz (see *Note)
140 MHz IFCF: 0.75 dB (±36 MHz), optional ±40 MHz (see *Note)
0.05 dB/MHz
36 or 72 MHz, optional 40 or 80 MHz (see *Note)
0.05 dB/MHz
Input, either 5 or 10 MHz Option @ +3 dBm
Optional 10 MHz Rear Panel Reference Output
Linear Group Delay 0.03 ns/MHz
Parabolic Delay 0.01 ns/MHz 2
Group Delay Ripple 1.0 ns Peak-to-Peak
Parameter Limit (dBc/Hz)
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
-69
-79
-89
-99
-109
Typical (dBc/Hz)
-72
-82
-92
-102
-112
1–10
UT-4500A Series Upconverters
Introduction
Characteristic
Remote Control (Rear Panel)
LED Indicators
(Front Panel)
Power On
Transmit
Remote
On Line
Test Points
(Front Panel)
Power
Specification
Comm Port EIA-485 or EIA-232
Green LED
Yellow LED
Yellow LED
Yellow LED
Fault
Stored Fault
RF Sample
IF Sample
Red LED
Red LED
Type ‘SMA’ Connector, -20 dBc Nominal
Type ‘BNC’ Connector, -20 dBc Nominal
Optional L.O. Sample
Voltage 90-250 VAC, Autoranging
Frequency 47-63 Hz
Dissipation
Environmental
Power Option
Temperature
60 Watts
-48 VDC
0-50°C (32-122° F)
Altitude
Physical
Humidity
Width
10,000 Feet MSL
0-95% Relative
19 Inches (48.26 cm)
Height 1RU 1.75 Inches (4.44 cm)
Depth
MTBF
Summary Alarm Relay Closure
Weight
22 Inches (55.88 cm)
15 Pounds (7.00 kg)
49,740 hrs. (calculated)
>100,000 hrs. (field experience)
Form C
Revision 0
MN-UT4500A
1–11
UT-4500A Series Upconverters
Introduction
1.4.3 UT-4505/I-A, /M-A Upconverters
Characteristic
Frequency Range UT-4505/I-A
UT-4505/M-A
Conversion
Specification
5845-6725 MHz
5725-6725 MHz
Dual, No Inversion
Step Size
Preset Channels
125 kHz standard, 1kHz optional
32 Frequencies and Gains
Stability over Time ± 1 x 10 -9 /Day
Stability over Temp ± 1 x 10 -8 0-50°C (32-122°F)
IF Input
RF Output
Noise Figure
Level
Range
Impedance
Return Loss
Output Level
Intermodulation
12 dB Maximum at 0 dB Attenuation
-35 dBm Typical
52-88 or 104-176 MHz
50 " or 75"
23 dB min. with IO Module or Switch Module
+17 dBm at 1 dB Compression
-50 dBc @ 0 dBm Output SCL
Carrier Mute -70 dBc
Non-carrier Spurious -80 dBm
Carrier Spurious
AM to PM
-65 dBc @ 0 dBm Output SCL
0.1
o . / dB for Output up to –5 dBm
Transfer
External Reference
Group Delay
Phase Noise
Return Loss
Impedance
20 dB Minimum with IO Module
50 "
Gain
Ripple
Slope
35 dB ± 2 dB
Attenuation Adjust 0-25 in 0.25 dB Steps
0.1 dB Steps Optional
Gain Stability ± 0.25 dB/Day
70MHz IFCF: ±0.25 dB (±18 MHz)
140 MHz IFCF: 0.75 dB (±36 MHz)
0.05 dB/MHz
Input either 5 or 10 MHz
Option @ +3 dBm
Optional 10 MHz Rear Panel Reference Output
Linear Group Delay 0.03 ns/MHz
Parabolic Delay 0.01 ns/MHz 2
Group Delay Ripple 1.0 ns Peak-to-Peak
Parameter Limit (dBc/Hz)
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
-69
-79
-89
-99
-109
Typical (dBc/Hz)
-72
-82
-92
-102
-112
1–12
Revision 0
MN-UT4500A
UT-4500A Series Upconverters
Introduction
Characteristic
Remote Control (Rear Panel)
LED Indicators
(Front Panel)
Power On
TRANSMIT
Remote
On Line
Fault
Stored Fault
Specification
Comm Port EIA-485 or EIA-232
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
Test Points
(Front Panel)
Power
Environmental
Physical
MTBF
Summary Alarm Relay Closure
RF Sample
IF Sample
Type ‘SMA’ Connector, -20 dBc Nominal
Type ‘BNC’ Connector, -20 dBc Nominal
Optional L.O. Sample
Voltage 90-250 VAC Autoranging
Frequency 47-63 Hz
Dissipation
Power Option
Temperature
60 Watts
-48 VDC
0-50°C (32-122° F)
Altitude
Humidity
Width
10,000 Feet MSL
0-95% Relative
19 Inches (48.26 cm)
Height 1RU 1.75 Inches (4.44 cm)
Depth
Weight
22 Inches (55.88 cm)
15 Pounds (7.00 kg)
49,740 hrs. (calculated)
>100,000 hrs. (field experience)
Form C
Revision 0
MN-UT4500A
1–13
UT-4500A Series Upconverters
Introduction
Revision 0
MN-UT4500A
1.4.4 UT-4514-A, /C-A, /D-A, /E-A, /F-A Upconverters
Characteristic Specification
Frequency Range UT-4514-A
UT-4514/C-A
UT-4514/D-A
UT-4514/E-A
UT-4514/F-A
Conversion
Step Size
Preset Channels
RF Output
14.00-14.50 GHz
12.75-13.25 GHz
13.75-14.50 GHz
14.70-15.00 GHz
12.75-14.50 GHz
Dual, No Inversion
125 kHz
32 Frequencies and Gains
Stability over Time ± 1 x 10 -9 /Day
Stability over Temp ± 1 x 10 -8 0-50°C (32-122°F)
Output Level +20 dBm at 1 dB Compression
Intermodulation
Carrier Mute
-60 dBc @ 0 dBm Output SCL
-70 dBc
Non-carrier Spurious -80 dBm
Carrier Spurious
AM to PM
Return Loss
IF Input
Transfer
Impedance
Noise Figure
Level
Range
Impedance
Return Loss
Gain
-65 dBc @ 0 dBm Output
0.1
o . / dB at –5 dBm Out
20 dB Minimum with RF/IF Connector Module
18 dB Minimum with Switch Module
50 "
13 dB Maximum at 0 dB Attenuation
-35 dBm Typical
52-88 or 104-176 MHz (optional 50-80 MHz or 100-180 MHz – see *Note)
50 " or 75"
23 dB Minimum with RF/IF Connector Module or Switch Module
35 dB ± 2 dB
External Reference
Group Delay
Phase Noise
Gain Adjust
Gain Stability
Ripple
Slope
Image Rejection
0-25 in 0.25 dB Steps
± 0.25 dB/Day
±0.25 dB
0.05 dB/MHz
-80 dB Inband
5 or 10 MHz, +3 dBm Nominal
Linear Group Delay 0.03 ns/MHz
Parabolic Delay 0.01 ns/MHz 2
Group Delay Ripple 1.0 ns Peak-to-Peak
Parameter Limit (dBc/Hz)
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
-72
-79
-89
-98
-110
Typical (dBc/Hz)
-79
-82
-92
-101
-114
1–14
UT-4500A Series Upconverters
Introduction
Characteristic
Remote Control (Rear Panel)
LED Indicators
(Front Panel)
Power On
Transmit
Remote
On Line
Fault
Stored Fault
Test Points
(Front Panel)
Power
Environmental
RF Sample
IF Sample
Voltage
Frequency
Dissipation
Temperature
Altitude
Humidity
Width Physical
Height
Depth
Weight
-1 Options
-2
Summary Alarm Relay Closure
Specification
Comm Port EIA-485 or EIA-232
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
Type ‘SMA’ Connector, -20 dBc Nominal
Type ‘BNC’ Connector, -20 dBc Nominal
90-250 VAC Autoranging
47-63 Hz
60 Watts
0-50°C (32-122° F)
10,000 Feet MSL
0-95% Relative
19 Inches (48.26 cm)
1RU 1.75 Inches (4.44 cm)
22 Inches (55.88 cm)
15 Pounds (7.00 kg)
RF/IF Connector Module
Transmit Switch Module
Form C
Revision 0
MN-UT4500A
1–15
UT-4500A Series Upconverters
Introduction
1.4.5 UT-4518-A, /E-A Upconverters
Characteristic
External Reference
Specification
Frequency Range UT-4518-A
UT-4518E-A
Conversion
Step Size
RF Output
17.30-18.10 GHz
17.30-18.40 GHz
Dual, No Inversion
125 kHz
Preset Channels 32 Frequencies and Gains
Stability over Time ± 1 x 10 -9 /Day
Stability over Temp ± 1 x 10 -8 0-50°C (32-122°F)
Output Level +10 dBm at 1 dB Compression
Intermodulation
Carrier Mute
-38 dBc @ 0 dBm Output SCL
-70 dBc
Non-carrier Spurious -80 dBm
Carrier Spurious -65 dBc @ 0 dBm Output
AM to PM
Return Loss
0.1
o . / dB for Output up to –5 dBm
20 dB Minimum with IO Module
18 dB Minimum with Switch Module
Impedance
IF Input
Transfer
Noise Figure
Level
Range
Impedance
Return Loss
Gain
Gain Adjust
Gain Stability
Ripple
50 "
13 dB Maximum at 0 dB Attenuation
35 dBm Typical
52-88 or 104-176 MHz
50 " or 75"
23 dB Minimum with IO Module or Switch Module
35 dB ± 2 dB
0-25 in 0.25 dB Steps
± 0.25 dB/Day
±0.25 dB/MHz
Slope 0.05 dB/MHz
5 or 10 MHz @ +3 dBm Nominal
Group Delay Linear Group Delay
Parabolic Delay
0.03 ns/MHz
0.01 ns/MHz 2
Group Delay Ripple 1.0 ns Peak-to-Peak
Phase Noise Parameter
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
Remote Control (Rear Panel)
LED Indicators
(Front Panel)
Power On
Transmit
Remote
On Line
Fault
Stored Fault
Limit (dBc/Hz)
-66
-76
-86
-96
-106
Comm Port EIA-485 or EIA-232
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
Typical (dBc/Hz)
-69
-79
-89
-99
-109
1–16
Revision 0
MN-UT4500A
UT-4500A Series Upconverters
Introduction
Characteristic
Test Points
(Front Panel)
Power
Environmental
Physical
Options
RF Sample
IF Sample
Voltage
Frequency
Dissipation
Temperature
Altitude
Humidity
Width
Height
Depth
Weight
-1
-2
Summary Alarm Relay Closure
Specification
Type ‘SMA’ Connector, -20 dBc Nominal
Type ‘BNC’ Connector, -20 dBc Nominal
90-250 VAC Autoranging
47-63 Hz
60 Watts
0-50°C (32-122° F)
10,000 Feet MSL
0-95% Relative
19 Inches (48.26 cm)
1RU 1.75 Inches (4.44 cm)
22 Inches (55.88 cm)
15 Pounds (7.00 kg)
IO Module
RF/IF Switch
Form C
Revision 0
MN-UT4500A
1–17
UT-4500A Series Upconverters
Introduction
Notes:
1–18
Revision 0
MN-UT4500A
Chapter 2. INSTALLATION
2.1 Unpacking and Inspection
The UT-4500-A Series Upconverter and its Installation and Operation Manual are packaged and shipped in a pre-formed, reusable cardboard carton containing foam spacing for maximum shipping protection.
Inspect shipping containers for damage. If shipping containers are damaged, keep them until the contents of the shipment have been carefully inspected and checked for normal operation.
CAUTION
Do not use any cutting tool that will extend more than 1” into the container
and cause damage to the converter.
Unpack and inspect the UT-4500-A Series Upconverter as follows:
Step Procedure
1 Cut the tape at the top of the carton indicated by OPEN THIS END.
2
3
4
5
6
Remove the cardboard/foam space covering the converter.
Remove the upconverter, manual, and power cord from the carton.
Save the packing material for storage or reshipment purposes.
Inspect the equipment for any possible damage incurred during shipment.
Check the equipment against the packing list to ensure the shipment is correct.
7 Refer to the next section (Section 2.2) for installation instructions.
CAUTION
The equipment contains parts and assemblies sensitive to damage by Electrostatic
Discharge (ESD). Use ESD precautionary procedures when touching, removing, or
inserting the up/downconverter modules.
2–1
UT-4500-A Series Upconverters
Installation
2.2 Installation
Revision 0
MN-UT4500A
2.2.1 Standard Rack Mount Installation
The UT-4500-A Series Upconverter is designed for installation in a standard 19-inch (48.26 cm)
rack cabinet or enclosure. Figure 2-1 provides a “cut-away” side view of a typical converter rack
installation.
The converter chassis requires 1RU (1-3/4 inches) of panel height space. Adequate air ventilation should be provided on both sides of the rack-mounted equipment. In rack systems where there is high heat dissipation, forced air cooling must be provided by top or bottom mounted fans or blowers. Under no circumstance should the highest internal rack temperature be allowed to exceed
50°C (122°F).
Figure 2-1. Standard Rack Cabinet Installation
2–2
UT-4500-A Series Upconverters
Installation
Revision 0
MN-UT4500A
2.2.2 Installation using Optional Rear-Mounting Support Brackets
Install optional rear-mounting support brackets using kits KT/6228-2 or KT/6228-3:
Quantity
KT/6228-2 KT/6228-3
2
–
2
4
2
4
2
–
2
2
4
2
4
2
Part Number
HW/10-32SHLDR
HW/10-32FLT
HW/10-32SPLIT
HW/10-32HEXNUT
HW/10-32x1/2RK
FP/6138-2
FP/6138-3
Description
Screw, #10 Shoulder
Washer, #10 Flat
Washer, #10 Split
Nut, #10 Hex
Bolt, #10 Rack Bracket
Bracket, Rear Support – 4”
Bracket, Rear Support – 10”
The tools required for this installation are a medium Phillips # screwdriver, a 5/32-inch SAE
Allen # Wrench, and an adjustable Crescent ® wrench.
The kit is installed as illustrated in Figure 2-2 via the following procedure:
Step
1
2
3
Procedure
Secure the #10 shoulder screws to the unit chassis through the rear right and left side mounting slots, using the #10 flat washers, #10 split washers, and #10 hex nuts as shown.
Install the rear support brackets onto the equipment rack threaded rear mounting rails, using the #10 rack bracket bolts.
Mount the unit into the equipment rack, ensuring that the #10 shoulder screws properly engage into the slots of the rear support brackets.
Figure 2-2. Optional Rear-Mounting Support Brackets Installation
2–3
UT-4500-A Series Upconverters
Installation
Revision 0
MN-UT4500A
2.2.3 Installation Using Optional Bearingless Rack Slide Sets
If the converter is to be mounted on slides, install an optional bearingless rack slide set into the rack cabinet, and onto the sides of the UT-4500-A using the hardware provided with the slide set determined to be appropriate for installation:
CEFD Part Number
FP/SL0006
FP/SL0008
Description
Bearingless Rack Slide Set – 26”
Bearingless Rack Slide Set – 24”
Per Figure 2-3, install any of these optional bearingless rack slide sets as follows:
Step
1
2
3
4
5
Procedure
Using the provided mounting hardware, install one slide onto each side of the UT-
4500-A chassis.
Using the provided mounting hardware, install the slide rail components into each side of the rack cabinet.
Mount the unit into the equipment rack, ensuring that the slides properly engage the cabinet-mounted slide rails.
Slide the converter into the rack cabinet until the front panel’s back surfaces abut the rack cabinet’s front mounting rails.
Secure the converter to the rack cabinet front mounting rails using four userprovided screws installed through the front panel mounting slots.
Figure 2-3. Optional Bearingless Rack Slide Installation (FP/SL000X)
2–4
UT-4500-A Series Upconverters
Installation
Revision 0
MN-UT4500A
2.3 Connect Prime Power Connection
The detachable power cord mates with the AC Prime power receptacle on the rear of the converter chassis. A power cord for connection to 90-125 VAC or 205-240 VAC power sources is provided with the converter.
2.4 Connect External Cables
Proceed to connect all external cables to the connectors outlined in the next chapter (Chapter 3.
REAR PANEL CONNECTIONS). Should difficulties occur, call Comtech EF Data Customer
Support for assistance.
2–5
UT-4500-A Series Upconverters
Installation
Notes:
2–6
Revision 0
MN-UT4500A
Chapter 3. REAR PANEL
CONNECTORS
3.1 Rear Panel Overview
Figure 3-1 shows the UT-4500-A Series Upconverter rear panel and its accessible connectors.
This example depicts a UT-4505-A Upconverter with a Transmit Switch Module, or TSM, installed.
Table 3-1 summarizes these connectors, which provide all necessary external connections
between the upconverter and other equipment. Detailed information about each connector follows.
Figure 3-1. UT-4500-A Rear Panel
3–1
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.2 UT-4500-A External Connectors
Location
(Chapter
Sect.)
Ref Des /
Connector Name
MAIN
CHASSIS
(3.2.1)
MODULE
(3.2.2)
Table 3-1. UT-4500-A Rear Panel External Connections
Prime Power
J2A REF IN
J2B REF OUT
Ethernet
P1 RELAY
J1 COM1
J3 HSB
J4 | IF
J6 | LP IN
J8 | LP OUT
J5 | RF
Chapter
Subsect. Description
3.2.1.1 AC Prime Power Input (AC POWER)
3.2.1.2 Optional –48 VDC Prime Power Input (DC POWER)
3.2.1.3 External Reference Oscillator Input
3.2.1.4 Optional External Reference Oscillator Output
3.2.1.5 100BASE-TX Ethernet Management & Control port (Telnet, SNMP)
3.2.1.6 Summary Fault Output
3.2.1.7 Serial Communications Interface for EIA-485/232 COMM links
3.2.2.1 High Speed Bus
3.2.2.2
Converter IF Input
IF TSM Switching Loop Input
IF TSM Switching Loop Output
Converter RF Output
3.2.1 Chassis-mounted Connectors
3.2.1.1 IEC Line Input (AC Power) Connector
The IEC line input connector contains the ON/OFF switch for the unit. It is also fitted with two fuses, one each for line and neutral connections
(or L1, L2, where appropriate). These are provided within the body of the connector, behind a small plastic flap.
A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies the Alternating
Current (AC) power to the UT-4500-A.
Observe the following:
Input Power
Input Voltage
Connector Type
Fuse Protection
IMPORTANT
AC Power Specifications
75W maximum, less than 65W typical
90-260VAC
IEC-320
Use T2.0A (slow-blow) 20mm fuses.
For continued operator safety, always replace the fuses with the correct type and rating.
3–2
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.2.1.2 DC Power Connector (Optional)
A standard 2-circuit terminal block with switch and fuse holder supplies the optional Direct Current (DC) power to the UT-4500-A.
Observe the following:
Input Power
Input Voltage
Connector Type
Fuse Protection
IMPORTANT
DC Power Specifications
75W maximum, less than 65W typical
36 to 72 VDC
Terminal Block
Use 3.15A (slow-blow) 20mm fuses.
For continued operator safety, always replace the fuses with the correct type and rating.
3.2.1.3 J2A | REF IN, External Reference Input Connector (BNC-F)
The J2A REF IN (External Reference Input) connector is a ‘BNC’ female connector used to supply a master reference to the entire chassis. The input signal supplied here by the user is used for phase-locking the internal 10MHz reference oscillator to a customer-provided 5 or 10 MHz station clock. The impedance is matched for 50/75 ", and requires an input level of 0 ±5 dBm.
3.2.1.4 J2B | REF OUT, External Reference Output Connector (BNC-F)
The optional J2B REF OUT (External Reference Output) connector is a ‘BNC’ female connector that provides a 10 MHz reference for customer use. The impedance is matched for 50/75 ", and provides an output level of 5 ±3 dBm.
3–3
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.2.1.5 100BASE-TX Ethernet M&C Port (RJ-45)
This is a standard RJ-45 female connector used for management via Telnet, SNMP, and HTTP (future). It is also used for upgrading UT-4500-A firmware. This receptacle uses a UTP cable to connect to an Ethernet hub, router, switch, PC, etc.
The pinout specifications are provided in Table 3-2.
Table 3-2. Ethernet M&C Interface Connector Pinout
Pin #
1
2
3
4
5
6
Description
Tx+
TX-
Rx+
N/A
N/A
Rx-
Direction
Out
Out
In
In
3.2.1.6 P1 RELAY, Summary Fault Output Connector (DB-9F)
The summary fault output connector, P1, is 9-pin Type "D" (DB-9F) connector. The mating connector is a DB-9M connector. The pinout
specifications are provided in Table 3-3.
6
7
4
5
8
9
Pin #
1
2
3
Table 3-3. P1 – Summary Fault Connector Pinout
Description Notes
Summ ary Fault NC 1. Pin 1 to Pin 6: Fault
Summary Fault NO
2. Pin 2 to Pin 6: OK (No Fault)
3. Pin 7 to Pin 5: Forced Fault (typically used with external group delay equalizers)
Ground
Summary Fault COM
EXT_FLT_IN#
3–4
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.2.1.7 J1 COM1 EIA-485/232 Interface Connector (DB-9F)
The J1 COM1 EIA-485/EIA-232 Interface connector is a 9-pin Type "D" female (DB-9F) connector. The mating connector is a DB-9M connector.
The pinout specification for EIA-485 is provided in Table 3-4 (2-wire) and
Table 3-5 (4-wire); the specification for EIA-232 is provided in Table 3-6.
Table 3-4. J1 – 2-Wire EIA-485 Pinout
Pin #
1
2
3
4
5
6
Description
GND; Ground
+RX/TX; Signal
-RX/TX; Signal Complement
7
8 +RX/TX; Signal
9 -RX/TX; Signal Complement
Note: Pins 8 and 9 are the loop to the next upconverter
Table 3-5. J1 – 4-Wire EIA-485 Pinout
7
8
9
4
5
6
Pin #
1
2
3
Description
GND; Ground
+TX; Signal
-TX; Signal Complement
+RX; Signal
-RX; Signal Complement
Table 3-6. J1 – EIA-232C Pinout
Pin # Description
1
2 TD; Transmit Data
3 RD; Receive Data
4
5 GND; Ground
6
7
8
9
3.2.1.8 Chassis Ground Connector
A #10-32 stud is used for connecting a common chassis ground among equipment.
Note: The AC power connector provides the safety ground.
3–5
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.2.2 Module-mounted Connectors
The information that follows pertains to the connectors provided on the available switch modules
(e.g., I/O Module (IOM), Receive Switch Module (RSM), and Transmit Switch Module (TSM)).
Quick reference tables listing all available modules are provided in Section 3.2.2.2.
Figure 3-2. IOM, RSM, and TSM Switch Modules
3–6
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.2.2.1 J3 HSB (High Speed Bus) Connector (DB-25F)
The J3 HSB connector is a Type “D” 25-pin female (DB-25F) connector is provided on all switch modules. The mating connector is a DB-25M connector. The pinout specifications are
Note: This connection does not employ a “straight-through” cable assembly. Contact Comtech
EF Data for detailed wiring drawings when cabling between converters.
Table 3-7. J3 HSB Interface Connector Pinout
22
23
24
19
20
21
25
16
17
18
13
14
15
10
11
12
7
8
9
Pin #
1
2
3
4
5
6
GND
Cntl_11
Cntl_9
Cntl_7
Cntl_5
Cntl_3
Cntl_1
+14V Out
+14V In
GND
Aux_2
GND
+Rx/Tx
Description
Cntl_12
Cntl_10
Cntl_8
Cntl_6
Cntl_4
Cntl_2
Cntl_In
+14V Out
+14V In
Aux_3
Aux_1
-Rx/Tx
3–7
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.2.2.2 Switch Module IF, RF, and Loop Connectors
The IF and RF input and output connectors, and the Loop input and output connector types vary depend on the band and impedence of the purchase unit. Modules are available for both nonredundant (also referred to as single thread or standalone) and redundanct configurations (see
Appendix B. REDUNDANT SYSTEM OPERATION for the specific use of these various switch module).
The tables that follow provide a quick reference to the available switch modules and their switching type, operating band, connector type, etc. for the UT-4500-A Series of Upconverters as well as the DT-4500-A Series of Down Converters. Contact Comtech EF Data for details and specifications for the specific system module(s).
Table 3-8. DT-4500-A and UT-4500-A Available Switch Module Assemblies
CEFD P/N
AS/0101-1
AS/0101-2
AS/0101-9
AS/0101-15
AS/0101-19
AS/0101-21
AS/0101-23
AS/0101-29
AS/0101-39
AS/0101-40
50
75
50
50
75
IOM Assemblies
Impedance
75
75
50
50
75
Comments
I/O, Type ‘SMA’
Non-switching, C-Band
Non-switching, C-Band
I/O, Type ‘SMA’
UT-4518-A w/isolator, Type ‘SMA’
UT-4518-A w/isolator
UT-4514F-A w/isolator, Type ‘SMA’
UT-4514F-A w/isolator, Type ‘SMA’ w/isolator, Type ‘SMA’ w/isolator
CEFD P/N
AS/0101-4
AS/0101-6
AS/0101-7
AS/0101-16
AS/0101-20
AS/0101-26
AS/0101-37
AS/0101-38
50
75
50
50
75
RSM Assemblies
Impedance
75
75
50
Comments
Switching, Ku-Band, down
Switching, C-Band, Type ‘N’
Switching, C-Band, Type ‘N’
I/O, Type ‘SMA’
Receive Switch, C-Band, RSM2
RSM2, Type ‘N’ w/isolator, Type ‘SMA’ w/isolator
CEFD P/N
AS/0101-3
AS/0101-5
AS/0101-8
AS/0101-17
AS/0101-18
AS/0101-22
AS/0101-27
AS/0101-28
AS/0101-42
AS/0101-43
75
75
50
50
75
50
TSM Assemblies
Impedance
75
75
50
50
Comments
Switching, Ku-Band, up
Switching, C-Band, up, Type ‘N’
Switching, C-Band, up
Switching, IF & RF, Type ‘SMA’
Switching IF & RF w/isolator
UT-4514F-A w/isolator, Type ‘SMA’
UT-4514F-A w/isolator, Type ‘SMA’
UT-4518-A w/isolator, Type ‘SMA’
DT-4513-A w/isolator, Type ‘SMA’
UT-4514F-A w/isolator
3–8
UT-4500-A Series Upconverters
Rear Panel Connectors
CEFD P/N
AS/0101-10
AS/0101-11
AS/0101-24
AS/0101-30
AS/0101-35
AS/0101-36
CEFD P/N
AS/0101-13
AS/0101-25
AS/0101-31
AS/0101-32
AS/0101-33
AS/0101-34
AS/0101-41
PSM Assemblies
Impedance
75
75
50
50
50
75
50
75
50
50
EQM Assemblies
Impedance
75
50
75
Revision 0
MN-UT4500A
Comments
Switching, Type ‘N’
Switching, Type ‘SMA’
RF Switching, Type ‘N’
Type ‘SMA’
Type ‘SMA’ w/isolator
Type ‘SMA’ w/isolator
Comments
EQM for 1:1, C- and Ku-Bands
1:N IF & RF Switch, Type ‘SMA’
UT-4514F-A w/isolator
UT-4514F-A w/isolator
UT-4518F-A w/isolator
UT-4518F-A w/isolator
1:1 Switching
3.3 Cable Connections
functions are listed in Table 3-1; see Section 3.2 for detailed information about each connector.
Figure 3-3. UT-4500-A Rear Panel (UT-4505-A with Receive Switch Module [RSM-XX] Shown)
3–9
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
3.3.1 Cable Connections – Standalone (Non-Redundant) Operation
In non-redundant (also referred to as standalone or single thread) upconverter configurations the upconverter has an Input/Output Module (IOM-XX) for the RF Input and the IF Output. An upconverter with a Transmit Switch Module (TSM-XX) may be operated in a non-redundant configuration if an IOM is unavailable.
Figure 3-4 shows a non-redundant configuration using with an IOM installed; Figure 3-5 shows
cabling accomplished with a TSM installed.
3.3.2 Cable Connections – Redundant System Operation
In subsystems where a redundant upconverter configuration is used, the backup upconverter has an Input/Output Module (IOM-XX) and the online converters have Transmit Switch Modules
(TSM-XX), which switch to the backup upconverter when a fault is detected. See Appendix B.
REDUNDANT SYSTEM OPERATION for a discussion of the upconverter’s use in redundant applications.
Figure 3-4. Standalone (Non-Redundant) Upconverter Configuration
3–10
UT-4500-A Series Upconverters
Rear Panel Connectors
Revision 0
MN-UT4500A
Figure 3-5. Standalone (Non-Redundant) Upconverter Configuration with Transmit Switch
Module (TSM-XX) Installed
3–11
UT-4500-A Series Upconverters
Rear Panel Connectors
Notes:
3–12
Revision 0
MN-UT4500A
Chapter 4. FLASH UPGRADING
4.1 Introduction
The UT-4500-A Series Upconverters use ‘Flash memory’ technology internally. This makes
software upgrading very simple, and updates can now be sent over satellite, via the Internet (Figure
The complete upgrading process is as follows:
! New firmware can be downloaded via the Internet to an external PC.
! The upgrade can be performed without opening the UT-4500-A by simply connecting the unit to the Ethernet or serial port of the external PC.
! The firmware update is transferred, via File Transfer Protocol (FTP), from the external
PC to the UT-4500-A.
Figure 4-1. Flash Upgrade via Internet
4–1
UT-4500-A Series Upconverters
Flash Upgrading
Revision 0
MN-UT4500A
4.2 About Firmware Files, Naming, Versions and Formats
All CEFD products are shipped configured with the current version firmware release. Firmware upgrades may be obtained from Comtech EF Data via download from the Internet to an external
PC, via e-mail, or on CD.
Comtech EF Data’s Web site catalogues its firmware upgrade files by product type (e.g., modem, converter, etc.) and specific model/optional configuration. For the purpose of example, the F0000202x_V### firmware download is specified in the procedural that follows, where ‘x’ denotes the revision letter, and V### represents the firmware version.
The firmware download files are available from Comtech EF Data in two file formats: *.exe (self extracting) and *.zip (compressed). Some firewalls will not allow the downloading of *.exe files; in this case, download the *.zip file instead. If applicable, one version prior to the current release is also available for download.
4–2
UT-4500-A Series Upconverters
Flash Upgrading
Revision 0
MN-UT4500A
4.3 Ethernet FTP Upload Procedure
Step Procedure
1
2
Identify the reflashable product, firmware number, and version for download.
The current unit M&C version can be viewed at the top-level menu of the front panel display
(press the [CLR] key several times to view). The firmware information can also be found within the UTILITY ! FIRMWARE! INFO ! IMAGE#1 or IMAGE#2 menu branches.
Using serial remote control, the firmware revision levels may be obtained with the <1/FRM? query. For more information, refer to Appendix A. REMOTE CONTROL.
Create a temporary folder (directory) on an external PC:
! For Windows Explorer: Select File > New > Folder to create a new folder, then rename it from “New Folder” to "temp" or another convenient, unused name. Assuming
"temp" works, a "c:\temp" folder should now be created.
Note: The drive letter c: is used in this example. Any valid writable drive letter can be used.
! For Windows Command-line: Click [Start] on the Windows taskbar, then click the
“Run...” icon (or, depending on Windows OS versions prior to Windows 95, click the
“MS-DOS Prompt” icon from the Main Menu). Then, to open a Command-line window… o For Windows 95 or Windows 98 – Type “command”. o For any Windows OS versions later than Windows 98 – Type “cmd” or
“command”. o Alternately, from [Start], select All Programs > Accessories > Command
Prompt.
At the Command-line prompt (c:\>), type “mkdir temp” or “md temp” (without quotes – mkdir and md stand for make directory). This is the same as creating a new folder from Windows
Explorer. There should now be a "c:\temp" subdirectory created (where c: is the drive letter used in this example).
4–3
UT-4500-A Series Upconverters
Flash Upgrading
Revision 0
MN-UT4500A
Step Procedure
3
4
5
6
Download the correct firmware file to this temporary folder. As shown in Figure 4-1: a) Go online to: www.comtechefdata.com; b) Click on: Support tab; c) Click on: Software Downloads drop-down or hyperlink from Support page; d) Click on: Download Flash and Software Update Files icon; e) Click on: (Select a Product Line) Converters hyperlink; f) Click on: The UT-4500-A Series product hyperlink; g) Select the appropriate UT-4500-A Series Product firmware hyperlink.
About Firmware Numbers, File Versions, and Formats: The flashable files on the download server are organized by product prefix; firmware number (verify that the correct firmware number is known – see Step 1) and, where applicable, revision letter and release version.
The UT-4500-A firmware archive file hyperlink is F0000202x_V### (where ‘x’ denotes the revision letter, and V### denotes the firmware version number).
The downloadable files are stored in two formats: *.exe (self-extracting) and *.zip
(compressed). Some firewalls will not allow the downloading of *.exe files. In this case, download the *.zip file instead.
For additional help with "zipped" file types, refer to PKZIP for Windows, WinZip, or ZipCentral help files. PKZIP for DOS is not supported due to file naming conventions.
Extract the files to the temporary folder on the PC. A minimum of two files should be extracted: a) FW-0000202x.bin – the bulk firmware file; b) ReleaseNotes_DT4500A_V###.pdf, or a similarly-titled file, where ‘V###’ denotes the firmware version number.
Confirm that the files have been extracted to the specified temporary folder on the PC. In
Command-line, use “cd c:\temp” to change to the temporary directory created in Step 2, then use the “dir” command to list the files extracted from the downloaded archive file.
Connect the client PC to the UT-4500-A’s 10/100 Ethernet M&C via a hub or a switch, or directly to the PC with a crossover cable.
7 Send a “ping” command to the unit to verify the connection and communication:
First, determine the IP address of the unit remotely or by using the UT-4500-A Front Panel:
! Via Remote Control – Use the <1/IPA? command
! Via Front Panel – Use the CONFIG ! REMOTE ! ETHERNET ! ADDRESS !
IP Address/ Range menu.
Then, using Command-line to PING: At the Command-line prompt, type “ping
xxx.xxx.xxx.xxx” (where ‘xxx.xxx.xxx.xxx’ is the Management IP address of the unit).
The results should confirm whether or not the unit is connected and communicating.
4–4
UT-4500-A Series Upconverters
Flash Upgrading
Revision 0
MN-UT4500A
Step Procedure
8
9
Initiate an FTP session with the unit (this example uses Command-line): a) From the PC, type "ftp xxx.xxx.xxx.xxx" where ‘xxx.xxx.xxx.xxx’ is the IP address of the UT-4500-A. b) Enter the Admin User Name (there will be no prompt for a password) to complete login. c) Verify the FTP transfer is binary by typing "bin". d) Type "prompt", then type "hash" to facilitate the file transfers.
Transfer the files from the temporary folder on the PC:
Type "put FW-0000202x.bin bulk:” to begin the file transfers. The destination “bulk:” must be all lower-case. Approximately one minute is required to transfer the file.
10 Verify the file transfer: a) The PC should report that the file transfer has occurred, and the display on the unit will start reporting “Programming App Flash … Please wait”. After a few minutes, the unit will display “Programming main FPGA … Please wait”. b) Terminate the FTP session by typing "bye" and close the Command-line window. c) Confirm that the new file was loaded by using the procedure in Step 1.
11 Change the desired image to boot.
From the UT-4500-A front panel menu: UTILITY ! FIRMWARE! SELECT.
Use the ! " arrow keys to change to the other image, then cycle power to reboot the unit.
12 Verify the new firmware version has booted by observing the firmware version displayed on the UT-4500-A front panel, for example:
DT_4500- 2
SW VER #.## SN#########
Note: To load the second image, repeat Steps 8 through 11.
The Flash Upgrade Procedure is now complete.
4–5
UT-4500-A Series Upconverters
Flash Upgrading
Notes:
4–6
Revision 0
MN-UT4500A
Chapter 5. FRONT PANEL
OPERATION
5.1 Introduction
Figure 5-1. UT-4500-A Front and Rear Panel Views
Figure 5-1 identifies the key operational features of the front and rear panels of the UT-4500-A
Series Upconverter. This example depicts a UT-4505-A equipped with a Transmit Switch
Module, or TSM.
The front panel features (from left): Two Test Point Sample Ports, Six Light-Emitting Diode
(LED) Indicators, a Vacuum Fluorescent Display (VFD); and a six-button keypad.
The Prime Power Switch, located on the rear panel, is an integral component of the IEC Line
Input (AC Power) Connector.
The function and behavior of the LED indicators, keypad, and VFD is described in detail in this chapter. The keypad comprises six individual keyswitches. The user can use the keypad and display to fully control and monitor the operation of the UT-4500-A from the front panel. The user enters data via the keypad, and messages are displayed on the VFD. Nested menus display
5–1
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A all available options and prompt the user to carry out a required action. The LEDs indicate, in a summary fashion, the status of the unit.
5.1.1 Switch Power On (Rear Panel)
UT-4500-A AC Power Switch UT-4500-A DC Power Switch
(Standard) (Optional)
Prior to turning on power to the unit, check to ensure that installation is complete, and verify that the UT-4500-A is connected to the proper prime power source, RF Input, and IF Output.
For more information, refer to Chapter 2. INSTALLATION and Chapter 3. REAR PANEL
CONNECTORS.
Switch on the unit and verify the cooling fan is operational, the LED indicators illuminate as expected, and the Vacuum Fluorescent Display is readable.
5.1.2 LED Indicators
The following table defines the operational condition, when lit, of the six front panel LED indicators:
LED
POWER ON
Color Operational Condition (When Lit)
Green Prime power is applied when the light is on.
OUTPUT ENABLE Yellow Transmit function operating when the light is on.
REMOTE Yellow In Remote Control Mode when the light is on.
ON LINE
FAULT
Yellow Operating on-line to transmit data when the light is on.
Red Fault condition exists when the light is on.
STORED FAULT Red Faults stored and logged when the light is on.
5–2
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.1.3 Keypad
The keypad comprises six individual keyswitches. They have a positive ‘click’ action, which provides tactile feedback. The function of the front panel keypad is as follows:
The ENTER key is used to select a displayed function or to execute a modem configuration change.
The CLEAR key is used to back out of a selection or to cancel a configuration change which has not been executed since ENTER was last pressed. Pressing
CLEAR generally returns the display to the previous selection.
(Up, Down)
(Left, Right)
IMPORTANT
These arrows are used to move to the next selection or to move the cursor position. Most of the menus (space permitting) include arrow key hints to guide the user.
These arrows are used primarily to change configuration data (numbers), at the current cursor position. Occasionally, they may be used to scroll through a number of choices at the current cursor position. Most of the menus (space permitting) include arrow key hints to guide the user.
The keypad has an auto-repeat feature. If a key is held down for more than 1 second, the key action will repeat, automatically, at the rate of 15 keystrokes per second. This is particularly useful when editing numeric fields, with many digits, such as frequency or data rate.
5.1.4 Vacuum Fluorescent Display (VFD)
The UT-4500-A features a Vacuum Fluorescent
Display (VFD). The VFD is an active display showing two lines of 24 characters each. It produces a blue light, the brightness of which can be controlled by the user. Compared to a Liquid Crystal
Display (LCD), it has greatly superior viewing characteristics and does not suffer problems of viewing angle or contrast.
On most menu screens, the user will observe a flashing solid block cursor, which blinks at a onceper-second rate. This indicates the currently selected item, digit, or field. Where this solid block cursor would obscure the item being edited (e.g., a numeric field) the cursor will automatically change to an underline cursor.
If the user were to display the same screen for weeks at a time, the display could become ‘burnt’ with this image. To prevent this, the unit has a ‘screen saver’ feature, which will activate after 1 hour. The top line of the display will display the circuit ID, and the bottom line will display
‘Press any key...’ The message moves from right to left across the screen, then wraps around. Pressing any key will restore the previous screen.
5–3
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.2 Opening Screen
UT_45XX –X
SW VER X.X.X SNXXXXXXXXX
This screen is displayed whenever power is first applied to the unit. When the prime power is turned on, this VFD ‘splash’ display indicates the upconverter model number – e.g., ‘UT_4505 -
2’ – along with the version number of the firmware installed, and the serial number assigned for the unit in use.
The opening screen may be accessed from any location within the UT-4500-A menu structure by pressing the CLEAR key repeatedly. Otherwise, press any key to access the main menu.
5.3 Main Menu
CONFIG MONITOR FAULTS
PRE-SELECTS UTILITY
The upconverter command menus are provided in a structured tree format designed for logical access and execution of all control functions, and to prevent the execution of an invalid entry by the operator.
The following table identifies each menu branch available from the main menu, its content section in this chapter, and the functional description of each branch:
Menu Branch Sect Description
CONFIG
MONITOR
FAULTS
5.3.1 (Configuration) Allows full configuration of the UT-4500-A.
5.3.2
Allows the real-time monitoring of system voltages, unit temperature, IFLO tuning, and Synth tuning,
5.3.3
The upconverter displays a total of one hundred (100) faults, which are date and time stamped and stored in memory as they occur. The stored faults remain in memory until a clear command is entered. When the number of faults reaches
100, the 100 th fault will display ER.
5.3.4 Allows configuration and recall of up to 32 pre-set operating selections. PRE-SELECTS
UTILITY 5.3.5
Allows configuration of such system functions as the Real-Time Clock, VFD brightness, unit ID, and firmware loading preferences.
Use the ! " arrow keys to select CONFIG, MONITOR, FAULTS, PRE-SELECTS, or
UTILITY, and then press ENTER.
5–4
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.3.1 CONFIG (Configuration)
OUTPUT REMOTE REDUNDANCY
FAULTRECOVERY COLDSTART
Use the ! " arrow keys to select from the submenu choices shown, and then press ENTER. Note the following:
Submenu Sect Functional Description
OUTPUT
REMOTE
REDUNDANCY
5.3.1.1
5.3.1.2
5.2.1.3
Allows user to define output frequency, attenuation, and set Rx operations as on or off.
(Remote Control) Allows definition of whether the unit is being controlled locally or remotely, and identifies the unit address, interface type, and rate and format of the baud parameters.
(Redundancy) Permits the user to identify the redundancy state and mode
(refer to Appendix B. UT-4500-A REDUNDANCY OPERATION for further information).
FAULTRECOVER
Y
5.3.1.4 Allows configuration of Fault Recovery in Auto or Manual mode.
COLDSTART 5.3.1.5
Allows user to mute the upconverter output signal for a pre-determined time after power is applied to the upconverter to ensure that the reference oscillator is stable.
5.3.1.1 CONFIG: OUTPUT
Frq=14500.000 MHz
Atten=00.00 dB Tx = Off
Typical for each parameter, use the ! " arrow keys to first navigate to a parameter to edit, and then use the # $ arrow keys to edit the value of that digit or setting.
Freq (Frequency): Displays the current upconverter frequency in MHz, and allows the selection of a new frequency channel between RF
Low
to RF
High
MHz in 125 KHz steps.
Atten (Attenuation): Displays the upconverter attenuation setting, and allows the selection of a new setting from 0.00 to 25.00 dB in 0.25 dB steps. The default setting is 10.00 dB.
Tx: Use the # $ arrow keys to set upconverter operation as On or Off. The default mode is Off.
Press ENTER when done.
5–5
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.3.1.2 CONFIG: REMOTE (Remote Control)
Remote Control: Local
SERIAL ETHERNET
Use the ! " arrow keys to select Local, SERIAL, or ETHERNET, and then press ENTER.
CONFIG: Remote Control ! Local
When Remote Control: Local is selected, then remote control will be disabled. Remote monitoring is still possible.
CONFIG: Remote Control ! SERIAL
Serial Mode = RS-232
Addr=001 Baud=9600 8-N-1
On the top line: To set the Serial Mode, use the # $ arrow keys to select RS-232 or
RS-485, and then press ENTER.
On the bottom line: To edit the Serial address, first use the ! " arrow keys to navigate to the digit to edit, and then use the # $ arrow keys to edit the value of that digit. The valid range of addresses is from 001 (default) to 255.
To edit the Baud Rate, first use the ! " arrow keys to navigate to the parameter, and then use the # $ arrow keys to select a different baud rate. Available choices are 1200, 2400,
4800, 9600 (default), 19K2, and 38K4.
To edit the asynchronous character format, first use the ! " arrow keys to navigate to the parameter, and then use the # $ arrow keys to select a different format. Available choices
(i.e., number of data bits; odd, even, or no parity; number of stop bits) are 8-N-1, 7-E-2, or
7-O-2.
Press ENTER when done.
CONFIG: Remote Control ! ETHERNET
ADDRESS GATEWAY SNMP
MAC = 00-06-B0-00-00-0F
On the bottom line: The unit MAC address is displayed here. This read-only menu shows the. Once the MAC address has been noted, exit this menu by pressing ENTER or CLEAR.
On the top line: Use the ! " arrow keys to select the parameter to configure – ADDRESS,
GATEWAY, or SNMP – and then press ENTER to continue.
5–6
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
CONFIG: Remote Control ! ETHERNET ! ADDRESS
IP Address/Range:
192.168.001.002/24
To edit the IP Address and Range for the Ethernet M&C port for this unit: First, use the
! " arrow keys to select the digit to edit, and then use the # $ arrow keys to edit the value of that digit. Press ENTER when done.
CONFIG: Remote Control ! ETHERNET ! GATEWAY
Ethernet IP Gateway:
192.168.001.002
To edit the IP Gateway Address for the Ethernet M&C port for this unit: First, use the !
" arrow keys to select the digit to edit, and then use the # $ arrow keys to edit the value of that digit. Press ENTER when done.
CONFIG: Remote Control ! ETHERNET ! SNMP
COMMUNITIES TRAPS
Use the ! " arrow keys to select the parameter to configure: COMMUNITIES or
TRAPS.
CONFIG: Remote Control ! ETHERNET ! SNMP ! COMMUNITIES
SNMP Communities:
READ WRITE TRAP
Use the ! "arrow keys to select READ, WRITE, or TRAP, and then press
ENTER.
CONFIG: Remote Control ! ETHERNET ! SNMP !
COMMUNITIES !READ
Read Community:
public
The user may view or edit the SNMP Read Community string. To edit, first use the
! "arrows keys to select the character to edit, and then use the # $ arrows keys to edit that character. Press ENTER when done.
CONFIG: Remote Control ! ETHERNET ! SNMP !
COMMUNITIES !WRITE
Write Community:
private
5–7
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
The user may view or edit the SNMP Write Community string. To edit, first use the ! "arrows keys to select the character to edit, and then use the # $ arrows keys to edit that character. Press ENTER when done.
CONFIG: Remote Control ! ETHERNET ! SNMP !
COMMUNITIES !TRAP
Trap Community:
comtech
The user may view or edit the SNMP Trap Community string. To edit, first use the
! "arrows keys to select the character to edit, and then use the # $ arrows keys to edit that character. Press ENTER when done.
CONFIG: Remote Control ! ETHERNET ! SNMP ! TRAPS
TRAPIP1 TRAPIP2 VERSION
IP1 IP2 Version
Use the ! " arrow keys to select TRAPIP1, TRAPIP2, or VERSION, and then press ENTER.
CONFIG: Remote Control ! ETHERNET ! SNMP ! TRAPS !
TRAPIP1/TRAPIP2
TRAP IP ADDRESS #1:
000.000.000.000
TRAP IP ADDRESS #2:
000.000.000.000
The user may view or edit the Trap Destination’s IP Addresses. To edit, first use the ! " arrow keys to select the digit to edit, and then use the # $ arrow keys to edit the value of that digit. Press ENTER when done.
Note: If both Trap IP Addresses are 000.000.000.000, it means Traps are disabled.
CONFIG: Remote Control ! ETHERNET ! SNMP ! TRAPS !
VERSION
Trap Version:
SNMPv1 SNMPv2
Use the # $ arrow keys to select the trap version – SNMPv1 or SNMPv2 – and then press ENTER.
5–8
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.3.1.3 CONFIG: REDUNDANCY
1:1 Redundancy is an optional feature for the UT-4500-A. If the user attempts to select any feature from this menu branch, and either Redundancy Configuration is off or the upconverter is the primary operating unit, the Redundancy menu branch appears as follows:
Redundancy: MODE
Otherwise:
Redundancy: MODE
Auto/Manual FORCE HSB
Use the ! " arrow keys to select MODE, Auto/Manual, FORCE, or HSB (High Speed Bus), and then press ENTER.
Note: If any submenu is selected from this menu branch when the unit is not in Local Mode (i.e., the unit is in either Serial or Ethernet Remote Mode), the system prompts the user to switch or
Local Mode as follows:
Remote Mode: press ENTER
for local mode, or CLEAR
Operations may continue once Local Mode is established.
CONFIG: REDUNDANCY ! MODE
Redundancy Config = On
CONVERTER = #BU 1:01
On the top line: First, use the ! " arrow keys to navigate to the Redundancy Config setting, and then use the # $ arrow keys to set operation as On or Off.
On the bottom line: First, use the ! " arrow keys to navigate to the Converter Selection setting, and then use the # $ arrow keys to toggle the upconverter operational preference as
#BU or #01. Note the following:
! With CONVERTER = #BU, the unit is set as the standby, or backup unit. This mode of operation is indicated on the right-hand side of the bottom line as 1:01.
! With CONVERTER = #01, the unit is set as the primary operating unit. The mode of operation is indicated on the right-hand side of the bottom line as POL=1.
5–9
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
CONFIG: REDUNDANCY !Auto/Manual
CONVERTER 123456789ABC
AUTO/MAN A-----------
Use this submenu to define backup as Automatic or Manual. This command provides for automatic switching by the backup upconverter if both units are in the Redundancy Mode.
This command is only accepted by the backup upconverter. If a chain upconverter is set in
Manual Mode, the backup upconverter will log the occurrence and not act upon further information from the upconverter until put into Automatic Mode.
On the top line: The unit in use and its Application ID (identification label) are displayed here.
On the bottom line: First, use the ! " arrow keys to navigate to the AUTO/MAN setting, and then use the # $ arrow keys to set toggle switchover as A (Automatic) or M (Manual).
CONFIG: REDUNDANCY !FORCE
CONV 01 OFFSET=+00.00 DB
ACTIVATE BACKUP = NO
On the top line: First, use the ! " arrow keys to navigate to the OFFSET operational threshold setting (i.e., the limit defined to automatically trigger switchover to the backup unit), and then use the # $ arrow keys to set that value in 0.25 dB increments.
On the bottom line: First, use the ! " arrow keys to navigate to the ACTIVATE
BACKUP setting, and then use the # $ arrow keys to set toggle switchover as NO (i.e., no backup will occur at the defined operational threshold), or FORCE (i.e., switchover will take place automatically if operation exceeds the predefined operational threshold.
Note that this submenu is operational only with a backup unit assigned, and with the switchover set as Automatic. In the absence of a designated backup unit and/or switchover set as Manual, the following message displays:
NO UNITS CURRENTLY
BACKED UP OR IN MANUAL
Press ENTER or CLEAR to return to the previous menus, and then reconfigure the system to operate as intended.
CONFIG: REDUNDANCY !HSB
CONV# 01 FRQ= 3625.000
ATTN=00.00 AUTO OK
In the "Daisy Chain" configuration, the backup upconverter communicates with the online units through the high-speed interface bus (HSB). The backup upconverter is able to detect faults and reconfigure itself to replace the faulted upconverter. The HSB interface is also
5–10
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A used in the backup Upconverter to monitor configuration changes made to an online upconverter. Changes in frequency, gain, or polarity are immediately entered into the backup table as well as information from new online units. The high-speed bus does not interfere with the remote serial communication link access to any of the converters in the chain.
The HSB (High Speed Bus) submenu is used to configure operation of the J3 HSB connector provided on the optional Receive Switch Module (RSM) and Transmit Switch Module
(TSM). When an RSM or TSM is not configured for operation, the following message displays:
CONV #01 – NO DATA
HSB NO RESPONSE
Press ENTER or CLEAR to continue.
See Appendix B. REDUNDANT SYSTEM OPERATION for detailed information about use of the front panel menus for redundancy configuration and operation.
5.3.1.4 CONFIG: FAULTRECOVERY
Fault Recovery: Auto
Use the # $ arrow keys to select Fault Recovery as Manual or Automatic, and then press
ENTER. The default operation is Auto.
5.3.1.5 CONFIG: COLDSTART
Cold Start = Disabled.
When redundancy is not active, use the # $ arrow keys to select Cold Start as Enabled or
Disabled, and then press ENTER. The default operation is Disabled.
Cold Start Mode, if enabled, mutes the upconverter output signal for a pre-determined time after power is applied to the upconverter – 15 minutes – to ensure that the reference oscillator is stable.
Note the following:
! The user must be in Local or Remote Mode to use this command. (Default is Remote.)
! This function is disabled in redundant systems.
5–11
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.3.2 MONITOR
Three read-only information screens are provided to monitor a number of operating voltage, temperature and tuning parameters. Use the # $ arrow keys to page between screens.
The following examples are provided for informational purposes only – the data displayed here for each parameter will vary depending on the operating conditions for the system in use:
15VDC=15.6V 14VDC=14.0V !
VCC=0.5V 5VDis=0.50V "
Converter Temp = +30.0C !
IFLO Tuning = 0.38V "
Synth Tuning: Sum=0.32V !
Coarse=06.0V Fine=03.5V "
Press ENTER or CLEAR to continue.
5.3.3 FAULTS
CURRENT STORED
Use the ! " arrow keys to select CURRENT or STORED, and then press ENTER.
5.3.3.1 FAULTS: CURRENT
Four read-only information screens are provided to monitor a number of operating parameters and return back whether the parameters are OK – i.e., operating within normal ranges, or FT – i.e., currently faulted. Use the # $ arrow keys to page between screens.
The following examples are provided for information purposes only – the data displayed here will vary depending on the operating conditions for the system in use:
Power Faults: 15VDC=OK !
14VDC=OK VCC=OK !
IFLO Lock Detect = OK !
!
Synth Faults: SumLD=OK !
FineLD=OK CoarseLD=OK !
Conv Temperature = OK !
High Speed Bus = OK !
Press ENTER or CLEAR to continue.
5–12
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.3.3.2 FAULTS: STORED (Stored Faults Log)
VIEW CLEAR-ALL
Use the ! " arrow keys to select View or Clear-All, and then press ENTER.
FAULTS: STORED !VIEW
If View is selected and no faults exist, the system displays the following message:
No Stored Faults.
The faults log can store up to 100 faults. When a fault condition occurs, it is date- and timestamped, and stored in the faults log with a number assigned in the order received. The fault information displays as per the following example:
Log05 01/23/11 09:27:15!
Fault – HSB !
When the fault condition clears, this is also recorded in the same fashion as the fault was originally recorded, as shown per the following example:
Log09 01/23/11 10:45:35!
Clear – HSB !
The stored faults remain in memory until the CLEAR-ALL command is entered. When the number of faults reaches 100, the 100 th fault will display ER.
The user may use the # $ arrow key to scroll backwards or forwards through the faults log.
Press ENTER or CLEAR to return to the previous menu.
FAULTS: STORED !CLEAR-ALL
Clear All Stored Faults
No Yes
Use the ! " arrow keys to choose No or Yes as prompted, and then press ENTER.
If Yes is selected, the faults log is cleared and the user is returned to the previous menu.
However, if there are faults present on the unit at this time, they will be re-stamped and new log entries will be generated.
5.3.4 PRE-SELECTS
#03 LOAD PROGRAM CLEAR !
5–13
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
03625.125 MHz 01.25 dB !
The user may create (program) up to 32 operating configurations, and recall them as needed. If any pre-selects exist, use the # $ arrow keys browse through the available pre-selects (i.e., #01 through #32), and then press ENTER.
Note: Upon initial selection – i.e., prior to the creation of any pre-selects – this menu branch appears as follows:
#XX LOAD PROGRAM CLEAR
No Pre-Select Programmed
Use the ! " arrow keys to select one of the following actions, and then press ENTER.
Selection Functional Description
LOAD
PROGRAM
CLEAR
Recalls a previously defined pre-select from memory.
Stores a defined set of operating parameters into memory for future recall.
Clears a previously defined pre-select from memory.
5.3.4.1 PRE-SELECTS: LOAD
Load this pre-select
Into converter? No Yes
LOAD is operable when pre-selects have previously been programmed into the unit via the
PROGRAM submenu. Use the ! " arrow keys to select No or Yes, and then press ENTER.
5.3.4.2 PRE-SELECTS: PROGRAM
Program pre-select? #XX
04200.000 MHz 01.25 dB
Select PROGRAM when it is desired to save an operational configuration for recall at a later date.
On the top line, first use the ! " arrow keys to navigate to the pre-select designator (#XX), and then use the # $ arrow keys to select a number from 01 to 32.
The read-only bottom line displays the operating parameters that will be stored into the designated slot (via this submenu), and then recalled via the LOAD submenu.
5.3.4.3 PRE-SELECTS: CLEAR
Clear this pre-select?
No Yes
5–14
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
Use the ! " arrow keys to select No or Yes to clear a previously saved parameter from memory. This will free up the slot for future pre-select programming needs. Press ENTER when done.
5.3.5 UTILITY
TIME DISP FIRMWARE AID
REFOSC SLOPE LAMP-TEST
Use the ! " arrow keys to select from the submenu choices shown, and then press ENTER. Note the following:
Submenu Sect Functional Description
TIME
DISP
AID
5.3.5.1 Allows configuration of the Real-Time Clock.
5.3.5.2
(Display) Allows adjustment of the Video Fluorescent Display (VFD) brightness level.
5.2.5.3 Allows definition of a unit identifier (label).
REFOSC
SLOPE
LAMP-TEST
5.3.5.4
(External Reference Oscillator) Allows adjustment of the upconverter reference frequency.
5.3.5.5 Allows adjustment of the upconverter slope settings.
5.3.5.6 Performs a diagnostic test of the front panel LEDs and VFD.
5.3.5.1 UTILITY: TIME (Real-Time Clock)
Edit Real-Time Clock:
12:00:00 01/23/11
To edit the time and date settings of the real-time clock, first use the ! " arrow keys to select the digit to be edited, and then use the # $ arrow keys to change the value of that digit. Press
ENTER when done.
Note: 24-hour Military time format is used.
5–15
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
5.3.5.2 UTILITY : DISP (VFD Display)
VFD Display Brightness:
100%
To edit the display brightness: Use the # $ arrow keys to select a brightness value of 25%,
50%, 75%, or 100%. Press ENTER when the brightness is suitable.
5.3.5.3 UTILITY: AID (Application Identification String)
Edit AID Message?
No Yes
The Application Identification (AID) command allows a free form message to be created. It is intended to identify the satellite, either transponder, beam, destination or other aspects of the application that may be significant to operations. The AID display alternates with the Equipment type display by use of the CLEAR key. The default is "AID MESSAGE".
To edit the AID message: First, use the ! " arrow keys to select No or Yes, and then press
ENTER. Then, to edit the Application ID string: For both the top and bottom lines of the display, first use the ! " arrow keys to select the character to edit, and then use the # $ arrow keys to edit that character.
A maximum of 24 characters are available on each line (48 characters in all), as follows:
[Space] ( ) * + - , . / 0-9 and A-Z.
UT-4500-A SERIES
48 CHAR MAX TST MESSAGE
Once the Application ID string is composed as per the above example, press ENTER.
5.3.5.4 UTILITY: REFOSC (Reference Oscillator Adjustment)
Reference frequency
adjustment = 087
The reference oscillator adjustment may be manipulated with this submenu. Use the ! " arrow keys to select the digit to edit, and then use the # $ arrow keys to edit the value of that digit. Press
ENTER when done.
The default Reference Frequency tuning adjustment is 087, with allowable values from 0 to 255.
5.3.5.5 UTILITY: SLOPE
Converter slope
5–16
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
adjustment = 0.0
The upconverter slope adjustment may be manipulated with this submenu. Use the ! " arrow keys to select the digit to edit, and then use the # $ arrow keys to edit the value of that digit. Press
ENTER when done.
The default upconverter slope adjustment is 0.0, with allowable values from 0.0 to 1.0.
5.3.5.6 UTILITY: LAMP-TEST
Start Lamp Test?
No Yes
To start the lamp test, use the ! " arrow keys to select No or Yes, and then press ENTER. The test begins with the following message:
Lamp Test in Progress
Please Wait
The front panel will then run through a series of diagnostics: the LED array will cycle, and then the
VFD will generate a series of test patterns. The VFD will return to the previous menu upon successful completion of the test.
Once the test has run, press CLEAR to return to the main menu. .
5.3.5.7 UTILITY: FIRMWARE
IMPORTANT
THESE MENUS ARE INTENDED FOR DIAGNOSTIC PURPOSES ONLY. DO NOT
CHANGE AN IMAGE UNLESS OTHERWISE INSTRUCTED BY COMTECH EF
DATA CUSTOMER SUPPORT.
This series of submenus permits the user to view information about the UT-4500-A internal firmware. The upconverter can store two complete firmware images, and the user can select which image will be loaded the next time the unit reboots.
Firmware Images:
INFO SELECT
Use the ! " arrow keys to select INFO or SELECT, and then press ENTER.
UTILITY: FIRMWARE ! INFO
Firmware Info: BOOTROM
IMAGE#1 IMAGE#2
Use the ! " arrow keys to select BOOTROM, IMAGE#1 or IMAGE#2, and then press ENTER to view the information.
The BOOTROM screen displays information similar to the example that follows:
5–17
UT-4500-A Series Upconverters
Front Panel Operation
Revision 0
MN-UT4500A
Bootrom: FW-0000200
X.X.X MM/DD/YY
For IMAGE#1 and IMAGE#2, each image is further broken down as follows (where IMAGE#X
denotes IMAGE#1 or IMAGE#2):
IMAGE#X: Bulk APP FPGA
Use the ! " arrow keys to select Bulk, App, or FPGA, and then press ENTER. The screens display information in a format similar to the examples that follow:
Bulk#X: FW-0000202
X.X.X MM/DD/YY
App#X: FW-0000203
X.X.X MM/DD/YY
FPGA#X: FW-0000204
X.X.X MM/DD/YY
UTILITY: Firmware ! SELECT
Current Active Image: #1
Next Reboot Image: #1 #2
The top line shows the Current Active Image. From the bottom line, use the ! " arrow keys to select the Next Reboot Image (i.e., the image that will be active the next time the unit is rebooted) as #1 or #2. Press ENTER when done.
If the image selected is already designated as the Next Reboot Image, the following message displays:
THAT IMAGE IS ALREADY
CURRENT. NO CHANGE MADE.
5–18
Chapter 6. ETHERNET
MANAGEMENT
6.1 Overview
This chapter describes the functionality of the UT-4500-A Series Upconverter Ethernet Interface.
Refer to the Remote Commands Specifications tables found in Appendix A. REMOTE
CONTROL for detailed descriptions of the configuration parameters available through these interfaces.
6.2 Ethernet Management Interface Protocols
The UT-4500-A’s 100BASE-TX Ethernet Management Interface supports two management protocols:
! SNMP with public and private MIB
! Telnet interface for remote product M&C
IMPORTANT
For SNMP or Telnet operation, the UT-4500-A must be configured with the
Ethernet control option. Via the front panel, select CONFIG: REMOTE !
ETHERNET. See Chapter 5. FRONT PANEL OPERATION for further information.
6.3 SNMP Interface
The Simple Network Management Protocol (SNMP) is an application-layer protocol designed to facilitate the exchange of management information between network devices. The UT-4500-A
SNMP agent supports both SNMPv1 and SNMPv2c.
IMPORTANT
For proper SNMP operation, the UT-4500-A MIB files must be used with the associated version of the UT-4500-A M&C. Refer to the UT-4500-A FW Release
Notes for information on the required FW/SW compatibility.
6–1
UT-4500-A Series Upconverters
Ethernet Management
Revision 0
MN-UT4500A
6.3.1 Management Information Base (MIB) Files
MIB files are used for SNMP remote management and consist of Object Identifiers (OID’s). Each
OID is a node that provides remote management of a particular function. A MIB file is a tree of nodes that is unique to a particular device.
The following MIB files are associated with the UT-4500-A:
MIB File/Name Description
FW-0000235-.mib
ComtechEFData
Root MIB file
ComtechEFData MIB file gives the root tree for ALL Comtech EF Data products and consists of only the following OID:
Name: comtechEFData
Type: MODULE-IDENTITY
OID: 1.3.6.1.4.1.6247
Full path: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtechEFData(6247)
Module: ComtechEFData
FW-0000205- .mib
UT-4500-A MIB file
MIB file consists of all of the OID’s for management of the amplifier functions
FW-0000206- .mib
UT-4500-A Traps
MIB file
Trap MIB file is provided for SNMPv1 traps common for UT-4500-A.
These MIB files should be compiled in a MIB Browser or SNMP Network Monitoring System server.
Note: As noted previously, the SNMP agent supports both SNMPv1 and SNMPv2c. The
“Traps” file only needs to be compiled if SNMPv1 traps are to be used.
6.3.2 SNMP Community Strings
The UT-4500-A uses community strings as a password scheme that provides authentication before gaining access to the UT-4500-A agent’s MIBs.
In SNMP v1/v2c, the community string is sent unencrypted in the SNMP packets. Caution must be taken by the network administrator to ensure that SNMP packets travel only over a secure and private network if security is a concern. A packet sniffer can easily obtain the community string by viewing the SNMP traffic on the network.
The community string is entered into the MIB Browser or Network Node Management software and is used to authenticate users and determine access privileges to the SNMP agent.
The user defines three Community Strings for SNMP access:
! Read Community default = public
! Write Community default = private
! Trap Community default = comtech
6–2
UT-4500-A Series Upconverters
Ethernet Management
Revision 0
MN-UT4500A
6.3.3 SNMP Traps
The UT-4500-A has the ability to send out SNMP traps when certain events occur in the unit. The
UT-4500-A sends out traps when a fault occurs in the unit. A trap is sent both when a fault occurs and is cleared.
The UT-4500-A supports both SNMPv1 traps and SNMPv2 notifications. Which style of traps the UT-4500-A sends can be configured by the user using the conv4500ASNMPTrapVersion
OID.
The following are the MIB2 v1traps / v2 notifications that the UT-4500-A supports:
MIB2 SNMPv1 trap: Authentication Failure 5
MIB2 SNMPv2 notifications: Authentication Failure 1.3.6.1.6.3.1.1.5.5
The following tables are the Faults v1 traps / v2 notifications that the UT-4500-A supports.
Faults SNMPv1 traps: conv4500APowerSupply15VFaultEventV1 62476401 conv4500APowerSupply14VFaultEventV1 conv4500AVccFaultEventV1 conv4500ATemperatureFaultEventV1
62476402
62476403
62476404 conv4500AIFLOLockFaultEventV1 conv4500ASumLockFaultEventV1 conv4500ACoarseLockFaultEventV1 conv4500AFineLockFaultEventV1 conv4500AHSBFaultEventV1 conv4500AEqualizerFaultEventV1 conv4500AExtRefOscFaultEventV1 conv4500ASummaryFaultV1
Faults SNMPv2 notifications: conv4500APowerSupply15VFaultEvent conv4500APowerSupply14VFaultEvent conv4500AVccFaultEvent conv4500ATemperatureFaultEvent conv4500AIFLOLockFaultEvent
62476405
62476406
62476407
62476408
62476409
62476410
62476411
62476412
1.3.6.1.4.1.6247.64.2.1.1
1.3.6.1.4.1.6247.64.2.1.2
1.3.6.1.4.1.6247.64.2.1.3
1.3.6.1.4.1.6247.64.2.1.4
1.3.6.1.4.1.6247.64.2.1.5
6–3
UT-4500-A Series Upconverters
Ethernet Management conv4500ASumLockFaultEvent conv4500ACoarseLockFaultEvent conv4500AFineLockFaultEvent conv4500AHSBFaultEvent conv4500AEqualizerFaultEvent conv4500AExtRefOscFaultEvent conv4500ASummaryFaultEvent
1.3.6.1.4.1.6247.64.2.1.6
1.3.6.1.4.1.6247.64.2.1.7
1.3.6.1.4.1.6247.64.2.1.8
1.3.6.1.4.1.6247.64.2.1.9
1.3.6.1.4.1.6247.64.2.1.10
1.3.6.1.4.1.6247.64.2.1.11
1.3.6.1.4.1.6247.64.2.1.12
Revision 0
MN-UT4500A
6.4 Telnet Interface
The UT-4500-A provides a Telnet interface for the purpose of Equipment M&C via the standard equipment Remote Control protocol.
The Telnet interface requires user login at the
Administrator level and
Read/Write level. The screen capture to the right shows the login process:
Once logged into the Telnet interface as Administrator, the user can access the standard remote control interface defined in Appendix A. REMOTE CONTROL.
6.4.1 HyperTerminal as Telnet Client
There is a disadvantage when using Windows Command-line as Telnet Client. Since Command-line cannot translate a ‘\r’ to a ‘\r\n’ for the messages coming from Telnet Server, the multi-line command response (for example, FRW? response) will be displayed as one line, with the latter lines overwriting the previous lines. In order to view the full response messages, CEFD recommends using
HyperTerminal configured as Telnet Client.
Configure HyperTerminal as follows:
1. Use TCP/IP (Winsock) instead of COM1 or COM2 for the connection, as per the example at right.
6–4
UT-4500-A Series Upconverters
Ethernet Management
Revision 0
MN-UT4500A
2. ASCII Setup (File! Properties !Settings!ASCII Setup):
Check the "Send line ends with line feeds" option in the
ASCII Sending section and the “Append line feeds to
incoming line ends" option in the ASCII Receiving section, as per the example at right.
Login and remote command execution via HyperTerminal configured as Telnet Client appears as per the following example:
6–5
UT-4500-A Series Upconverters
Ethernet Management
Notes:
6–6
Revision 0
MN-UT4500A
Appendix A. REMOTE CONTROL
A.1 Introduction
This appendix describes the protocol and message command set for remote monitor and control of Comtech EF Data’s UT-4500-A Series Upconverters.
The electrical interface is either an EIA-485 multi-drop bus (for the control of many devices) or an EIA-232 connection (for the control of a single device), and data is transmitted in asynchronous serial form, using ASCII characters. Control and status information is transmitted in packets of variable length, in accordance with the structure and protocol defined in later sections.
NOTE
The Remote Control connector pinout is shown in Chapter 3.2.1.7 J1 COM1 EIA-
485/232 Interface Connector (DB-9F)
A.2 Communication Interfaces
A.2.1 TIA/EIA-485 (RS-485)
For applications where multiple devices are to be monitored and controlled, a full-duplex (4-wire plus ground) EIA-485 is preferred. Half-duplex (2-wire plus ground) EIA-485 is possible, but is not preferred. In full-duplex EIA-485 communication, there are two separate, isolated, independent, differential-mode twisted pairs, each handling serial data in different directions.
It is assumed that a 'Controller' device (a PC or dumb terminal) transmits data in a broadcast mode via one of the pairs. Many 'Target' devices are connected to this pair, and all simultaneously receive data from the Controller. The Controller is the only device with a line-driver connected to this pair; the Target devices have only line-receivers connected.
In the other direction: On the other pair, each Target has a tri-state line driver connected; the
Controller has a line-receiver connected. All the line drivers are held in high-impedance mode until one – and only one – Target transmits back to the Controller. Each Target has a unique address; each time the Controller transmits, the address of the intended recipient Target is included in a framed 'packet' of data. All of the Targets receive the packet, but only one (the
A–1
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A intended) will reply. The Target enables its output line driver and transmits its return data packet back to the Controller in the other direction on the physically separate pair.
EIA-485 (Full Duplex) summary:
! Two differential pairs - one pair for Controller-to-Target, one pair for Target-to-Controller.
! Controller-to-Target pair has one line driver (Controller), and all Targets have line-receivers.
! Target-to-Controller pair has one line receiver (Controller), and all Targets have tri-state drivers.
A.2.2 TIA/EIA-232 (RS-232)
This is a much simpler configuration in which the Controller device is connected directly to the
Target via a two-wire-plus-ground connection. Controller-to-Target data is carried, via EIA-232 electrical levels, on one conductor, and Target-to-Controller data is carried in the other direction on the other conductor.
A.2.3 Ethernet (100BASE-TX)
The unit implements a Telnet server that will accept Telnet terminal connections using
Transmission Control Protocol (TCP) on port 23. After entering the username (default: comtech), and the password (default: comtech) the Telnet server will accept the same syntax used by the serial interfaces.
A.3 Access Methods
Downconverters may be accessed directly by using a physical address or indirectly through a backup downconverter by using a virtual address.
A.3.1 Direct Access
Converters may be directly accessed by the EIA-232 interface or by the EIA-485 interface in a bus configuration.
In this control network, all converters including the backup converter are paralleled on a common
EIA-485 cable. Both up and down converters can be mixed on the cable as long as each converter has a unique physical address. Only one EIA-485 port is required on the system's monitor and control computer. If a change is initiated directly to a converter in a redundancy subsystem, the backup converter will detect the change via the High Speed Bus and update its backup tables.
For EIA-232 control, a direct EIA-232 cable connection is made to each converter to be accessed.
If an external Monitor and Control Computer is used, one EIA-232 port per converter is required.
This mode is commonly used with an ASCII terminal for bench testing.
A–2
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.3.2 Indirect Access
Converters in Redundancy Mode may be addressed indirectly by adding a virtual address to the backup converter's physical address. The virtual address corresponds to the converter's position in the redundant subsystem. The backup converter recognizes the virtual address and executes the command via the high speed bus.
To control by using the EIA-485 interface, one or more backup converters are connected to a system's monitor and control computer or ASCII terminal with a common EIA-485 bus cable.
Both up and down backup converters may be mixed on the cable as long as each has a unique device address. In order to indirectly address an online converter in the subsystem, a virtual address must be provided. The virtual address corresponds to the converter's position in the chain beginning with number 1. Virtual addressing is only recognized by a backup converter. Only one
EIA-485 port is required on the monitor and control computer.
To control by using the EIA-232 interface, one EIA-232 port on the monitor and control computer is required for each backup converter. Virtual addressing must be established by command. All converters including the backup converter must be in the Redundancy Mode.
A.4 Addresses
All converters are addressed in a command by the Device Address. The Device Address consists of a physical address or a physical address plus a virtual address.
A.4.1 Physical Address
Each converter in the system must have a unique physical address regardless of the access method used. The physical address consists of a string of 1, 2 or 3 numbers from 1 to 255. The physical address is entered into a converter via the front panel. For Direct Access, the physical address is the only address required to command a converter. A backup converter or a standalone converter can only be accessed with a physical address.
Example: 10 (Addresses converter whose physical address is 10.)
A.4.2 Virtual Address
In order to access a converter controlled by a backup converter indirectly, a virtual address is required. A virtual address is appended to the physical address of the backup converter with a
"V". The virtual address is a number from 1 to 12 and corresponds to the position of the active converter from the backup converter and is assigned by a configuration command.
Example: 10V3 (Addresses the third converter controlled by the backup converter whose physical address is 10.)
A–3
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.4.3 IP Address
The IP address is a unique address on a network that supports Internet Protocol (i.e., IPv4). An example of a network address using IPv4 is 192.168.1.4 (factory default IP address). This value must be configured correctly to allow a Telnet session to control the unit.
A.5 Basic Protocol
Whether in EIA-232 or EIA-485 mode, all data is transmitted as asynchronous serial characters, suitable for transmission and reception by a UART.
All data is transmitted in framed packets. The Controller is assumed to be a PC or ASCII dumb terminal that is in charge of the process of monitor and control. The Controller is the only device that is permitted to initiate, at will, the transmission of data. Targets are only permitted to transmit when they have been specifically instructed to do so by the Controller.
All bytes within a packet are printable ASCII characters, less than ASCII code 127. In this context, the Carriage Return and Line Feed characters are considered printable.
All messages from Controller-to-Target require a response, with one exception: This will be either to return data that has been requested by the Controller, or to acknowledge reception of an instruction to change the configuration of the Target. The exception to this is when the Controller broadcasts a message (such as Set Time/Date) using Address 0, when the Target is set to EIA-485 mode.
A.5.1 Transmission Mode
The transmission mode is half duplex implemented in Command/Response convention. This method requires the external system monitor and control unit to initiate all communications by command and all converters to respond with either confirmation or an error message. The confirmation may contain status information.
A.5.2 Baud Rate
The supported baud rates are 1200, 2400, 4800, 9600 (default), 19200, and 38400 baud.
A.5.3 Asynchronous Character Format
The asynchronous character format is 8-N-1 (i.e., 8 data bits; no parity; 1 stop bit).
A.5.4 Character Set
The command syntax uses the printable ASCII character set.
A.5.5 Response Timeout
A minimum of 500 milliseconds is provided before declaring a “no response” instance, at which time the command is re-transmitted.
A–4
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.5.6 Bus Inactivity Requirement
Comtech EF Data recommends that a minimum of 50 milliseconds bus inactivity be provided by the user between the receipt of a response from an addressed converter and issuing the next command on the serial bus.
A.6 Message Structure
The structure of a Command, Response, or Error Message is as follows:
! Start Character
! Device Address
! Command or Response
! End of Message String
A.6.1 Start Character
The Start Character begins each message:
Example: < Start of a user Command.
> Start of a converter response.
A.6.2 Device Address
The Device Address consists of a Physical Address or a Physical Address and an appended
Virtual Address. For this document DEV is used for the generic case examples.
Example: <3V12
A.6.3 Command
A Command is a variable length character string beginning with a forward slash “/”’ and containing either an instruction or an instruction and data for a converter to act upon. If data is passed by command it is appended to the instruction by an underscore “_”. If data is retrieved by command underscore follows the instruction flagging the converter to supply data in a response.
Note: In this appendix, “/COM” is used for the generic case examples.
Example:
Example:
<DEV/COM_xxx'cr'
<DEV/COM_'cr'
(Sends data to a converter.)
(Requests information from a converter.)
A–5
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.6.4 Confirmation Response
A confirmation will change the start character, and echo the Device Address and Command. Any requested data will be appended to the Command.
Example: >DEV/COM_xxx'cr''lf']
A.6.5 Error Response
If a converter cannot execute a Command or detects a protocol violation, an error response is generated. An error is flagged by changing the “/” command designator in the response to a "?".
Following the "?" error symbol are two characters which are unique error symbols useful for computer analysis. The two error symbols are followed by a text string explaining the error for the convenience of a human operator. For this appendix, “ER” is used for the generic case examples response.
Example: >DEV?COM ER Error Message 'cr''lf']
A.6.6 End of Message
End of message strings were devised in such a way that an orderly screen presentation would result when converters are controlled by simple ASCII terminals.
A.6.6.1 Command Ending
The end of message for a command is a carriage return. For this appendix, “cr” is used for the carriage return.
Example: <DEV/COM_'cr'
A.6.6.2 Response Ending
End of message for a response is a carriage return, line feed and a bracket: “'cr''lf']”.
Example: >DEV/COM_'cr''lf']
A–6
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7 Command / Response Pairs
A.7.1 Utility Commands
A.7.1.1 Time
Command
Set Time:
Confirmation:
Retrieve Time:
Confirmation:
Details
<DEV/TIM_hh:mm:ss'cr'
Where: hh=Hour mm=Minutes ss=Seconds
>DEV/TIM_hh:mm:ss'cr''lf']
<DEV/TIM_'cr'
>DEV/TIM_hh:mm:ss'cr''lf']
A.7.1.2 Date
Command
Set Date:
Confirmation:
Retrieve Date:
Confirmation:
Details
<DEV/DAT_mm/dd/yy'cr’
Where: mm=Month dd=Day yy=Year
>DEV/DAT_mm/dd/yy'cr'lf']
<DEV/DAT_'cr'
>DEV/DAT_mm/dd/yy'cr''lf']
A.7.1.3 Local / Remote Status
The LRS command is used to enable or disable remote communications interfaces. The factory default setting is 3 (Ethernet and Serial remote control enabled).
Command Details
Set Local / Remote
Status:
Confirmation:
Retrieve LRS:
Confirmation:
<DEV/LRS_x'cr’
Where: x=
0 for front panel control only (remote control disabled)
1 for serial remote control
2 for Ethernet control
3 for Ethernet and serial remote control
>DEV/LRS_x'cr'lf']
<DEV/LRS_'cr'
>DEV/LRS_x'cr''lf']
A–7
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.1.4 Media Access Control (MAC) Address
The MAC command is used to query the unique MAC address of the unit’s Ethernet management port.
Command
Retrieve MAC:
Details
<DEV/MAC_'cr'
Confirmation: >DEV/MAC_xx-xx-xx-xx-xx-xx'cr''lf']
Where: xx=MAC address byte in hexadecimal
A.7.1.5 IP Address
The IPA command is used to set the IP address and network prefix for the 100BASE-TX Ethernet management port. The factory default value is 192.168.1.4.24.
Command Details
Set IP Address:
Confirmation:
Retrieve IP Address:
Confirmation:
<DEV/IPA_aaa.bbb.ccc.ddd.yy'cr’
Where: aaa = 0-223 bbb = 0-255 ccc = 0-255 ddd = 0-255, but they cannot all be zero. yy is the Subnet Mask Length (range: 8 to 30)
>DEV/IPA_ aaa.bbb.ccc.ddd.yy'cr'lf']
<DEV/IPA_'cr'
>DEV/IPA_ aaa.bbb.ccc.ddd.yy'cr''lf']
A.7.1.6 IP Gateway
The IPG command is used to set the IP gateway address for the Ethernet management port. The factory default value is 192.168.1.5.
Command Details
Set IP Gateway:
Confirmation:
Retrieve IP Gateway:
Confirmation:
<DEV/IPG_aaa.bbb.ccc.ddd'cr’
Where: aaa = 0-223 bbb = 0-255 ccc = 0-255 ddd = 0-255, but they cannot all be zero.
>DEV/IPG_ aaa.bbb.ccc.ddd'cr'lf']
<DEV/IPG_'cr'
>DEV/IPG_ aaa.bbb.ccc.ddd'cr''lf']
A–8
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.1.7 Physical Address
The default physical address is 001.
Command Details
Set Physical Address:
Confirmation:
Retrieve Phys. Addr:
Confirmation:
<DEV/SPA_xxx'cr' xxx = 1 to 255
>DEV/SPA_xxx'cr''lf']
<DEV/SPA_'cr'
>DEV/SPA_xxx'cr''lf']
A.7.1.8 Baud Rate
The default baud rate is 9600.
Command Details
Set Baud Rate:
Confirmation:
Retrieve Baud Rate:
Confirmation:
<DEV/SBR_xxxx'cr' xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4
>DEV/SBR_xxxx'cr''lf']
<DEV/SBR_xxxx'cr'
>DEV/SBR_xxxx'cr''lf']
A.7.1.9 LCD Contrast
This legacy command does not control any hardware, but its syntax is still supported to allow backwards compatibility with existing monitor and control applications. The default LCD contrast is 15.
Command
Set Contrast:
Confirmation:
Retrieve Contrast:
Confirmation:
Details
<DEV/CON_xx'cr' xx = 0 to 30
>DEV/CON_xx'cr''lf']
<DEV/CON_'cr'
>DEV/CON_xx'cr''lf']
A.7.1.10 LCD Brightness
This legacy command does not control any hardware, but its syntax is still supported to allow backwards compatibility with existing monitor and control applications. The default LCD brightness is 15.
Command
Set Brightness
Confirmation:
Retrieve Brightness:
Confirmation:
Details
<DEV/LCD_xx'cr' xx = 0 to 30
>DEV/LCD_xx'cr''lf']
<DEV/LCD_'cr'
>DEV/LCD_xx'cr''lf']
A–9
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.1.11 Screen Saver Mode
This legacy command does not control any hardware, but its syntax is still supported to allow backwards compatibility with existing monitor and control applications. The default screen saver mode is 0.
Command
Set SSM:
Confirmation:
Details
<DEV/SSM_x'cr'
Where: x=0 to 5
>DEV/SSM_x'cr''lf']
Retrieve SSM:
Confirmation:
<DEV/SSM_'cr'
>DEV/SSM_x'cr''lf']
A.7.1.12 Screen Saver Timeout
This legacy command does not control any hardware, but its syntax is still supported to allow backwards compatibility with existing monitor and control applications. The default screen saver timeout is 05.
Command
Set SST:
Confirmation:
Retrieve SST:
Confirmation:
Details
<DEV/SST_xx'cr' xx = 00 to 99
>DEV/SST_xx'cr''lf']
<DEV/SST_'cr'
>DEV/SST_xx'cr''lf']
A.7.1.13 VFD Brightness
The VFD command allows the front panel brightness to be adjusted from 0% to 100% in 25% steps. The default VFD brightness is 100.
Command Details
Set VFD:
Confirmation:
Retrieve VFD:
Confirmation:
<DEV/VFD_xxx'cr' xx = 000 to 100 (in 025 steps)
>DEV/VFD_xxx'cr''lf']
<DEV/LCD_'cr'
>DEV/VFD_xxx'cr''lf']
A.7.1.14 Reference Oscillator Tuning
The default reference oscillator tuning value is 087.
Command
Set Oscillator:
Confirmation:
Retrieve Tuning:
Confirmation:
Details
<DEV/SRO_xxx'cr' xxx = 0 to 255
>DEV/SRO_xxx'cr''lf']
<DEV/SRO_'cr'
>DEV/SRO_xxx'cr''lf']
A–10
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.1.15 Converter Slope Adjustment
The default slope adjustment value is 0.3.
Command
Set Slope Adjust:
Confirmation:
Retrieve Slope Adjust:
Confirmation:
Details
<DEV/SSA_xxx'cr' xxx = 0.0 to 1.0
>DEV/SSA_xxx'cr''lf']
<DEV/SSA_'cr'
>DEV/SSA_xxx'cr''lf']
A.7.1.16 Equipment Type
Equipment type is a query that retrieves the model number and the software revision of the unit.
This data is read-only.
Command Details
Retrieve Equipment Type:
Confirmation:
<DEV/RET_'cr'
>DEV/RET_xxxxxxxxxx yyyyyyy'cr’’lf'] xxxxxxxxxx = Model Number yyyyyyy = Software Version.
A.7.1.17 Part Number
The PNM command retrieves the unit’s part number information. This data is read-only.
Command
Retrieve Part Number:
Confirmation:
Details
<DEV/PNM_'cr'
>DEV/PNM_xx…xx'cr’’lf']
Where: xx…xx = up to 96 bytes of part number information
A.7.1.18 Legacy Firmware Information
This legacy firmware command no longer provides information about the unit’s firmware type. It is included only to provide backwards compatibility with existing monitor and control software applications. To query the unit’s firmware information refer to the FRM command.
Command
Retrieve Firmware Information:
Confirmation:
Details
<DEV/FRW_’cr’
>DEV/FRW_’cr’
BULK= FWnnnn-nr Ver=x.xx’cr’
M&C = FWnnnn-nr Ver=x.xx’cr’
FPGA= FWnnnn-nr Ver=x.xx’cr’’lf’]
Where: nnnn-n firmware number r firmware revision x.xx firmware version
Note: BULK, M&C, and FPGA have different firmware numbers, revisions, and versions among each other.
A–11
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.1.19 Firmware Information
This command returns information about the firmware loaded in the unit including firmware numbers, versions, and release dates. This command replaces the legacy FRW command.
Command
Retrieve Firmware Information:
Details
<DEV/FRM_’cr’
Confirmation: >DEV/FRM_’cr’
Boot: ’cr’
FW-AAAAAAA B.B.BB DD/MM/YY’cr’
Bulk1: ’cr’
FW-AAAAAAA B.B.BB DD/MM/YY’cr’
FW-AAAAAAA B.B.BB DD/MM/YY’cr’
FW-AAAAAAA B.B.BB DD/MM/YY’cr’
Bulk2: ’cr’
FW-AAAAAAA B.B.BB DD/MM/YY’cr’
FW-AAAAAAA B.B.BB DD/MM/YY’cr’
FW-AAAAAAA B.B.BB DD/MM/YY’cr’’lf’]
Where:
FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
A.7.1.20 Firmware Image
This command allows a valid bulk image to be selected as the next active image during boot-up.
Command
Set Next FW Image:
Details
<DEV/IMG_x'cr' x = 1 to 2
Confirmation:
Retrieve Active FW
Image:
Confirmation:
>DEV/IMG_x'cr''lf']
<DEV/IMG_'cr'
>DEV/IMG_x'cr''lf']
A.7.1.21 Application Identification
The Application Identification (AID) command allows a free form message to be created. It is intended to identify either the satellite, transponder, beam, destination or other aspects of the application that may be significant to operations.
The message length corresponds to capability of the LCD and is 48 characters in total. The second line begins at character 25, therefore, blanks must be used after line 1 information in order to space to line 2. A carriage return ends the command. Trailing blanks will be generated to fill the LCD field. The AID display will alternate with the Equipment type display by use of the clear function key on the front panel. The default is "AID MESSAGE".
A–12
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
Command
Application ID:
Confirmation:
Retrieve ID:
Confirmation:
Details
<DEV/AID_xxxxxxx ... xxxxx'cr'
>DEV/AID_'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf']
<DEV/AID_'cr'
>DEV/AID_'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr' xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf']
Note: xxxxxxx ... xxxxx = Your message, maximum 48 characters.
A.7.1.22 Force Reboot
The FRB command allows the unit to be forced to reboot after five seconds. This value is writeonly.
Command
Force Reboot:
Confirmation:
Details
<DEV/FRB_YES'cr'
>DEV/FRB_YES'cr''lf']
A.7.2 Configuration Commands
A.7.2.1 Frequency
The default RF frequency of the unit is equal to its minimum operating frequency (RF
Low
).
Command Details
Set Frequency:
Confirmation:
Retrieve Frequency:
Confirmation:
<DEV/FRE_xxxxx.xxx'cr'
>DEV/FRE_xxxxx.xxx'cr''lf']
<DEV/FRE_'cr'
>DEV/FRE_xxxxx.xxx'cr''lf']
Note: For example, xxxx.xxx = 14000.000 to 14500.000 MHZ in 125 KHz steps for Model
UT 4514-A
A.7.2.2 Attenuator
The default attenuation value is 10.00 dB.
Command
Set Attenuator:
Confirmation:
Retrieve Attenuator:
Confirmation:
Details
<DEV/ATT_ yy.yy'cr'
>DEV/ATT_yy.yy'cr'lf']
<DEV/ATT_'cr'
>DEV/ATT_ yy.yy'cr''lf']
Note: yy.yy = 00.00 to 25.00 dB in 0.25 dB steps.
A–13
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.2.3 Cold Start
The cold start function, if enabled, mutes the output signal for a predetermined time following
Power-Up to ensure a stable reference oscillator (15 minutes). The default is OFF. This command is disabled in redundant systems (i.e., COMMAND NOT AVAILABLE).
Command
Set Cold Start:
Details
<DEV/CLD_xxx'cr' xxx = ON or OFF
Confirmation:
Retrieve Status:
Confirmation:
>DEV/CLD_xxx'cr''lf']
<DEV/CLD_'cr'
>DEV/CLD_xxx'cr''lf']
A.7.2.4 Mute
The default RF mute state is ON (output is muted).
Command Details
Mute Output:
Confirmation:
Retrieve Mute Status:
Confirmation:
<DEV/MUT_xxx'cr' xxx = ON or OFF
>DEV/MUT_xxx'cr''lf']
<DEV/MUT_'cr'
>DEV/MUT_yyy'cr''lf'] yyy = ON/OFF/COLD
A.7.2.5 Carrier Mute Mode
The carrier mute mode determines the mute state of the unit during frequency changes. The default carrier mute mode state is OFF (output is muted during frequency changes).
Command
Mute Mode:
Confirmation:
Retrieve CMM Status:
Confirmation:
Details
<DEV/CMM_xxx'cr' xxx = ON or OFF
>DEV/CMM_xxx'cr''lf']
<DEV/CMM_'cr'
>DEV/CMM_xxx'cr''lf']
A.7.2.6 Redundant Mute Mode
The redundant mute mode determines how the backup unit handles the mute state during a redundant switchover condition. If the redundant mute mode is ON then the backup unit’s mute state will be the same as the primary unit that it is backing up. Otherwise, if the redundant mute mode is off the backup unit will unmute its output any time a redundant switchover occurs.
The default redundant mute mode state is OFF (backup unit’s output automatically unmutes when a redundant switchover occurs).
A–14
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
Command
Set CRM:
Confirmation:
Retrieve CRM:
Confirmation:
Details
<DEV/CRM_xxx'cr' xxx = ON or OFF
>DEV/CRM_xxx'cr''lf']
<DEV/CRM_'cr'
>DEV/CRM_xxx'cr''lf']
A.7.2.7 Auto Fault Recovery
The converter output is automatically muted in the event of a detected fault. Auto Fault
Recovery, if enabled, will cause the output signal to go active (unmuted) if all faults clear. If disabled, the output will remain muted even after all faults clear until a MUT_OFF command is received (see 4.8.2.4). If Auto Fault Recovery is enabled and the converter detects the same fault more than five times in a five minute interval (ex: multiple IFLO lock detect faults) the function reverts to DISABLED and the converter remains muted. The default is ON.
Command
Set Fault Recovery:
Confirmation:
Retrieve Status:
Confirmation:
Details
<DEV/AFR_xxx'cr' xxx = ON or 0FF
>DEV/AFR_xxx'cr''lf']
<DEV/AFR_'cr'
>DEV/AFR_xxx'cr''lf']
A.7.2.8 Program Preset
This command Is used to store up to 32 preset frequency and attenuation settings.
Command
Program Preset:
Details
<DEV/PGM_nn_xxxxx.xxx_yy.yy'cr'
Confirmation: >DEV/PGM_nn_xxxxx.xxx_yy.yy'cr''lf']
Note: nn = Preset Number = 01 to 32. xxxx.xxx = Frequency = RFLow to RFHigh (for example, 14000.000 to 14500.000 MHZ for Model UT-4514). yy.yy = Attenuator = 00.00 to 25.00.
A.7.2.9 Display All Presets
This command is used to display all of the programmed preset values.
Command
Display Presets:
Confirmation:
Details
<DEV/DPS_'cr'
>DEV/DPS_'cr'
P01 xxxxx.xxx yy.yy'cr'
to
P32 xxxxx.xxx yy.yy'cr''lf']
Where: xxxxx.xxx = Frequency
yy.yy= Attenuator
A–15
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
Note: Only programmed preset numbers are returned. If no preset(s) is programmed, “No Pre-
Selects Programmed” is returned.
A.7.2.10 Clear Preset Configuration
This command is used to clear a single preset value.
Command
Clear a Preset:
Details
<DEV/CLR_nn'cr'
Confirmation: >DEV/CLR_nn_Cleared'cr''lf']
Note: nn = Preset Number = 01 to 32.
A.7.2.11 Select Preset Configuration
This command is used to configure the converter to the frequency and attenuation data assigned to a given preset number.
Command
Select Preset:
Confirmation:
Details
<DEV/SEL_nn'cr'
>DEV/SEL_nn_Selected'cr''lf']
Note: nn = Preset Number = 01 to 32.
Only programmed preset numbers are available.
A.7.3 Modes
There are two modes of operation that may intersect: Redundant Mode and Automatic Mode.
A.7.3.1 Redundant Mode
Since the default mode is OFF, each converter including the backup converter must be commanded into the Redundant Mode.
Polling on the high speed bus will not begin until the position assignments are made.
Command
Redundant Mode:
Details
<DEV/RED_xxx'cr' xxx = ON or OFF
Confirmation:
Redundant Status:
Confirmation:
>DEV/RED_xxx'cr''lf']
<DEV/RED_'cr'
>DEV/RED_xxx'cr''lf']
Note: The primary units must all be configured properly in redundant mode before redundant mode is enabled on the backup unit.
Each converter's chain position must be initialized including the backup converter. The following redundancy initialization command is only allowed if Redundancy Mode has been selected.
A–16
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
Command
Initialize Command:
Confirmation:
Initialize Status:
Confirmation:
Details
<DEV/ICT_xx_yy'cr'
>DEV/ICT_xx_yy'cr''lf']
<DEV/ICT_'cr'
>DEV/ICT_xx_yy'cr''lf'] xx = chain position = 01 to 12, or BU. Where BUselects the converter as the backup. yy = chain length for xx = BU (i.e. Backup converter) 01 to 12. yy = unused if xx = 01 to 12 (i.e. chain converter)
Example 1: The following command assigns the converter chain position "1".
<DEV/ICT_01'cr'
>DEV/ICT_01'cr''lf']
Example 2: The following command assigns the receiving converter as the backup converter in a 1:8 system.
<DEV/ICT_BU_08'cr'
>DEV/ICT_BU_08'cr''lf']
Important: It should be reiterated that only the converter physically located at the top of a redundant rack should be assigned as the Backup unit. Likewise, assignment of chain positions in a redundant rack should be made according to the physical allocation of each converter in the rack (i.e. The top converter should be the Backup, the second converter should be assigned chain position 1, the third converter position 2, etc.).
A.7.3.2 Automatic/Manual Mode
This command provides for automatic switching by the backup converter if both units are in the
Redundancy Mode. This command is only accepted by the backup converter. If a chain converter is set in Manual Mode, the backup converter will log the occurrence and not act upon further information from the converter until put into Automatic Mode. The default is off.
Command
Automatic Mode:
Confirmation:
Automatic Status:
Confirmation:
Details
<DEV/SAM_xx_y'cr'
>DEV/SAM_xx_y'cr''lf']
<DEV/SAM_xx_'cr'
>DEV/SAM_xx_y'cr''lf']
Where: xx = 01 to 12, converter number y = A for Auto; M for Manual
A.7.3.3 Backup Mode
This command allows the user to force a backup condition for maintenance and test purposes.
This command must be sent to the converter designated as the backup converter (i.e., “BU”).
When activated this command forces the backup converter to assume the state of the specified chain converter and forces the chain converter offline.
A–17
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
Command
Initiate a Backup:
Confirmation:
Details
<DEV/FBU_xx_y'cr'
>DEV/FBU_xx_y'cr''lf']
Where: xx = 01 to 12, converter number y = ‘F’ to force a backup ‘N’ to remove a backup
Retrieve Backup Status: <DEV/FBU_'cr'
Confirmation: >DEV/FBU_xx_zzzzz'cr''lf']
Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter number is not displayed. zzzzz = ‘NONE’ if no backup active
= ‘ACTIVE’ if an automatic backup has occurred
= ‘FORCED’ if a forced backup is active
A.7.4 Status Commands
Status commands retrieve configuration, maintenance and alarm status in summary form.
A.7.4.1 Configuration Status
Command
Configuration Status:
Confirmation:
Details
<DEV/RCS_'cr'
>DEV/RCS_'cr'
FRE_xxxxx.xxx'cr' Frequency
ATT_yy.yy'cr'
TX_nnn'cr'
CLD_nnn'cr'
AFR_nnn'cr'
EXT_xxx'cr''lf']
Attenuator
Transmitter - ON/OFF/COLD
ONL_nnn'cr'
RED_xx_yy_z'cr' See Note
Online - ON/OFF
Cold Start - ON/OFF
Auto Flt Recovery-ON/OFF
Ext. Ref. - YES/NO
Note: If Redundancy OFF xx_yy_z = OFF, else if Redundancy ON and converter selected as backup controller xx_yy_z = BU_yy where yy is the number of converters in the chain (i.e. 01 to
12), else if Redundancy ON and converter selected as a chain unit xx is the converter number (01 to 12), and z = A if Auto Mode or M if Manual Mode.
A.7.4.2 Maintenance Status
Command
Maintenance Status:
Confirmation:
Details
<DEV/RMS_'cr'
>DEV/RMS_'cr'
P15_xx.x'cr'
P14_xx.x'cr'
VCC_x.x'cr'
5VD_x.x'cr'
TEM_xx'cr'
IFL_xx.x'cr'
SUM_xx.x'cr'
COR_xx.x'cr'
15 Vdc Supply
14 Vdc Supply
VCC Supply
Display 5 Vdc
Temperature
IFLO Tuning
Sum Loop Tuning
Coarse Loop Tune
FIN_xx.x'cr''lf'] Fine Loop Tuning.
A–18
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.4.3 Utility Status
Command
Utility Status:
Confirmation:
Details
<DEV/RUS_'cr'
>DEV/RUS_'cr'
COMM_aaaaaa'cr' RS-232 or RS-485
ADD_xxx'cr'
BR_nnnn'cr'
FMT_x-y-z’cr’
REF_xxx'cr'
SLP_x.x'cr'
CON_xx'cr'
LCD_xx'cr''lf']
Address (001 to 255)
Baud Rate (1200, 2400, 4800, 9600,
19K2, or 38K4)
Data Format x=data, y=parity, z=stop bit (8-N-1, 7-E-2, 7-O-2)
Osc. Adjust (000 to 255)
Slope Adjust (0.0 to 1.0)
LCD Contrast (0 to 30)
LCD Brightness (0 to 30).
A.7.4.4 Alarm Status
Command
Alarm Status:
Details
<DEV/RAS_'cr'
Confirmation: >DEV/RAS_'cr'
P15_xx'cr'
P14_xx'cr'
15 Vdc Fault
14 Vdc Fault
VCC_xx'cr'
5VD_xx'cr'
VCC Fault
5VD Fault
TEM_xx'cr' Temperature Fault
IFL_xx'cr' IFLO Lock Fault
SUM_xx'cr' Sum Lock Fault
COR_xx'cr' Coarse Lock Fault
FIN_xx'cr' Fine lock Fault
HSB_xx’cr’ High Speed Bus Fault
*REF_xx'cr''lf'] Ref. Lock Fault xx = OK or FT
Note: REF_xx is only returned if an external reference is present.
A.7.4.5 Summary Alarm Status
Summary alarm is set to Fault (FT) if any items in Sect. A.7.4.4 are faulted.
Command Details
Summary Alarm:
Confirmation:
<DEV/SAS_'cr' xx = OK or FT
>DEV/SAS_xx'cr''lf']
A.7.4.6 Terminal Status Change
The TSC_ command can be used to determine if the status of the terminal has changed since it was last polled. If any of the parameters listed in the RCS or RUS commands have changed as a result of user front panel operations or remote operations or if any new fault condition occur the
TSC_ command will return YES. The TSC_ command will then continue to return YES until any
A–19
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A of the following commands are received: RCS_, RUS_, RAS_, PACRCS_, PACRUS_, or
PACRAS.
Command
Configuration Status:
Confirmation:
Details
<DEV/TSC_'cr’
>DEV/TSC_nnn'cr''lf'] nnn=YES/NO
A.7.4.7 Packed Configuration Status
Configuration Status:
Confirmation:
<DEV/PACRCS_'cr'
>DEV/PACRCS_aaaabbbcdeffgghijkl'cr''lf'] where: aaaa = # of 125kHz steps above base frequency 1 bbb = # of 0.25 dB steps above 0.00 dB 2 c d e ff
= 1 if Transmitter ON, 0 if OFF, 2 if Cold
= 1 if unit ONLINE, 0 if OFFLINE
= 1 if Redundancy ON, else 0
= converter # (01-12,BU or 00 if e = 0) gg gg gg h
I j k l
= 00 if 'ff' is 00 (redundancy OFF)
= chain length (01-12) if 'ff' is BU
= XX if 'ff' = 01 - 12
= A if Auto Mode, M if Manual
= 1 if Cold Start Enabled, else 0
3
= 1 if Auto recovery enabled, else 0
= 1 if an Ext. Ref is present, else 0
= 1 if Remote Mode, 0 if Local Mode
Notes:
1. If the converter is 1 kHz step size, this will be the number of 1 kHz steps above the base frequency
2. If the converter is 0.1 -dB step size, this will be the number of 0.1 -dB steps above the base frequency
3. If it is a backup converter, it is always ‘A’
A.7.4.8 Packed Maintenance Status
Packed Maintenance Status: <DEV/PACRMS_'cr'
Confirmation: >DEV/PACRMS_aabbccddeeeffgghhii'cr''lf'] where: aa bb bc
= V15 scaled 123mV per count (0x00 - 0xFF)
= V14 scaled 123mV per count (0x00 - 0xFF)
= VCC scaled 39mV per count (0x00 - 0xFF) dd eee ff gg hh ii
= V5D scaled 39mV per count (0x00 - 0xFF)
= signed Temperature in degrees C (-10 to +60)
= IFLO tune scaled 67mV per count (0x00 - 0xFF)
= SUM tune scaled 54mV per count (0x00 - 0xFF)
= COARSE tune scaled 78mV per count(0x00 - 0xFF)
= FINE tune scaled 89mV per count (0x00 - 0xFF)
A–20
UT-4500-A Series Upconverters
Appendix A
A.7.4.9 Packed Utility Status
Packed Utility Status:
Confirmation: where: a
<DEV/PACRUS_'cr'
>DEV/PACRUS_abbcdeeffghhii'cr''lf']
= 0=EIA-232, 1=EIA-485 bb c
= Address in hex (01 to FF)
= 0 if Baud Rate 38400
= 1 if Baud rate 19200
= 2 if Baud rate 9600 d ee ff g hh ii
= 3 if Baud rate 4800
= 4 if Baud rate 2400
= 5 if Baud rate 1200
= 0 if Data Format 8-N-1
= 1 if Data Format 7-E-2
= 2 if Data Format 7-O-2
= Osc. Adjust in hex (00 to FF)
= Slope Adjust times by 10 (00 to 10)
= Always 0, unused
= LCD Contrast (0 to 30)
= LCD Brightness (0 to 30)
A.7.4.10 Packed Alarm Status
Packed Alarm Status:
Confirmation: where: a b c d e
<DEV/PACRAS_'cr'
>DEV/PACRAS_abcdefghijk'cr''lf']
= 1 if V15 Fault, else 0
= 1 if V14 Fault, else 0
= 1 if VCC Fault, else 0
= 1 if V5D Fault, else 0
= 1 if TEMP Fault, else 0 f g h
I j k
= 1 if IFLO Fault, else 0
= 1 if SUM Fault, else 0
= 1 if COARSE Fault, else 0
= 1 if FINE Fault, else 0
= 1 if HSB Fault, else 0
= 1 if EXT REF Fault, else 0
Revision 0
MN-UT4500A
A–21
UT-4500-A Series Upconverters
Appendix A
Revision 0
MN-UT4500A
A.7.5 Stored Alarms
Up to 100 alarms are date/time stamped and stored in memory as they occur. The alarm entry is also updated with its date/time of clearance. The entry remains in memory until it is cleared by command.
A.7.5.1 Total Stored Alarms
This command retrieves the total number of stored alarms and the time and date of the most recent alarm.
Retrieve Total Alarms:
Confirmation:
<DEV/TSA_'cr'
>DEV/TSA_TOTAL:nn'cr'
LAST:hh:mm:ss mm/dd/yy'cr''lf'] where: nn = 0 to 99; the 100th alarm will be ER hh.mm.ss mm/dd/yy
= time in hour:minute:second
= date in month/day/year
A.7.5.2 Clear All Stored Alarms
Clear Alarms:
Confirmation:
<DEV/CAA_YES'cr'
>DEV/CAA_CLEARED'cr''lf']
A.7.5.3 List All Alarms
This command retrieves a list of the stored alarms. This command is currently unavailable when using virtual addressing mode.
List All Alarms:
Confirmation:
<DEV/LAA_'cr'
>DEV/LAA_'cr' xx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr'
"
"
"
"
"
"
"
" xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr''lf']
Where: xx = stored fault number yyyyyyyyyyy = fault description hh:mm:ss mm/dd/yy
= fault time
= fault date
A–22
UT-4500-A Series Upconverters
Appendix A
A.7.6 Error Processing
Revision 0
MN-UT4500A
A.7.6.1 General Errors
The following Error Responses may be generated by any command instead of a confirmation:
>DEV?COM CU CMD UNRECOGNIZED'cr''lf']
>DEV?COM IP INVALID PARAM'cr''lf']
>DEV?COM PE PARITY ERROR'cr''lf']
A.7.6.2 Configuration Errors
The following Error Responses may be generated by configuration commands:
>DEV?COM LO DEVICE IN LOCAL MODE'cr''lf']
A.7.6.3 Mode Errors
The following Error Responses may be generated by Mode selection:
>DEV?COM AE ONLY VALID WHEN BACKUP'cr''lf']
>DEV?COM OE OFFLINE NOT AVAILABLE'cr''lf']
>DEV?COM CN COMMAND NOT AVAILABLE'cr''lf']
A.7.6.4 Time-Outs
A time-out should be assumed if there is no response in 500 milliseconds. The station monitor and control computer should try at least three times.
A–23
UT-4500-A Series Upconverters
Appendix A
A.7.7 Command Summaries
A.7.8 User Remote Command Summary
Utility
Set Time
Set Date
Set Local / Remote Status
Get MAC Address
Get IP Address
Get IP Gateway
Set Physical Address
Set Baud Rate
Set LCD Contrast
Set LCD Brightness
Set Screen Saver Mode
Set Screen Saver Timeout
Set VFD Brightness
Set Reference Oscillator
Set Converter Slope Adj.
Get Equipment Type
Get Part Number
Get Legacy Firmware Information
Get Firmware Information
Set Firmware Image
Set Application ID Message
Set Force Reboot
Configuration
Set Frequency
Set Attenuation
Select Cold Start Mode
Mute/Unmute Converter
Set Carrier Mute Mode
Set Redundant Mute Mode
Set Fault Recovery Mode
Set a Preset
Get All Presets
Clear a Preset
Select a Preset
Redundancy Mode
Select Redundancy ON/OFF
Configure Redundant Converter
Select Auto/Manual Mode
Forced Backup Mode
Commands
<DEV/TIM_hh:mm:ss'cr'
<DEV/DAT_mm/dd/yy'cr'
<DEV/LRS_x'cr'
<DEV/MAC_ 'cr'
<DEV/IPA_'cr'
<DEV/IPG_'cr'
<DEV/SPA_xxx'cr'
<DEV/SBR_xxxx'cr'
<DEV/CON_xx'cr'
<DEV/LCD_xx'cr'
<DEV/SSM_x'cr'
<DEV/SST_xx'cr'
<DEV/VFD_xxx'cr'
<DEV/SRO_xxx'cr'
<DEV/SSA_xxx'cr'
<DEV/RET_'cr'
<DEV/PNM_'cr'
<DEV/FRW_'cr'
<DEV/FRM_'cr'
<DEV/IMG_x'cr'
<DEV/AID_xxxxx...xxxxx'cr'
<DEV/FRB_YES'cr'
Commands
<DEV/FRE_xxxxx.xxx'cr'
<DEV/ATT_xx.xx'cr'
<DEV/CLD_xxx'cr'
<DEV/MUT_xxx'cr'
<DEV/CMM_xxx'cr'
<DEV/CRM_xxx'cr'
<DEV/AFR_xxx'cr'
<DEV/PGM_nn_xxxxx.xxx_yy.yy'cr'
<DEV/DPS_'cr'
<DEV/CLR_nn'cr'
<DEV/SEL_nn'cr'
Commands
<DEV/RED_xxx’cr’
<DEV/ICT_xx_yy’cr’
<DEV/SAM_xx_y'cr'
<DEV/FBU_xx_y'cr'
Revision 0
MN-UT4500A
A–24
UT-4500-A Series Upconverters
Appendix A
Status
Retrieve Configuration Status
Retrieve Maintenance Status
Retrieve Utility Status
Retrieve Alarm Status
Summary Alarm Status
Terminal Status Change
Packed Configuration Status
Packed Maintenance Status
Packed Utility Status
Packed Alarm Status
Stored Alarm
Retrieve Total Stored Alarms
Clear All Stored Alarms
List All Stored Alarms
Commands
<DEV/RCS_'cr'
<DEV/RMS_'cr'
<DEV/RUS_'cr'
<DEV/RAS_'cr'
<DEV/SAS_'cr'
<DEV/TSC_'cr'
<DEV/PACRCS_'cr'
<DEV/PACRMS_'cr'
<DEV/PACRUS_'cr'
<DEV/PACRAS_'cr'
Commands
<DEV/TSA_'cr'
<DEV/CAA_YES'cr'
<DEV/LAA_'cr'
Revision 0
MN-UT4500A
A–25
UT-4500-A Series Upconverters
Appendix A
Notes:
A–26
Revision 0
MN-UT4500A
Appendix B. REDUNDANT
SYSTEM OPERATION
B.1 Introduction to Redundancy Operation
The Comtech EF Data UT-4500-A Series Upconverters are configured for redundant system operation using distributed protection switching in an active "Daisy Chain" configuration.
Comtech EF Data's proprietary "Daisy Chain" configuration distributes the upconverter protection switching functions in the upconverters. This provides a system capability to backup from 1 to 12 online upconverters.
A High Speed Bus (HSB) provides the communications interface between the backup and online upconverters to detect faults and reconfigure the subsystem to replace the failed upconverter.
When a faulted upconverter is removed from active operation, it is detached from the active upconverter chain by separating the upconverter from its switch module, leaving the active online upconverter chain intact through the switch module. The chain can be extended without affecting the online upconverter operation.
The active "chained" upconverters in a redundancy subsystem can also be indirectly controlled through the backup upconverter using the remote serial communication link – this capability is discussed in Appendix A. REMOTE CONTROL.
B.2 Backup Upconverter
The "Daisy Chain" terminates in the backup upconverter. The backup upconverter has a microprocessor, which performs fault detection, self-reconfiguration and the logical switching functions. If the backup upconverter does not have a fault, it will assume the frequency and attenuation of the faulted upconverter and compensate for the chain losses. This capability is accomplished through the operation of the HSB and the online upconverter detachable switch modules.
B.2.1 High Speed Bus (HSB)
In the "Daisy Chain" configuration, the backup upconverter communicates with the online units through the HSB. The backup upconverter is able to detect faults and reconfigure itself to replace
B–1
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A the faulted upconverter. The HSB interface is also used in the backup converter to monitor configuration changes made to an online upconverter. Changes in frequency, gain, or polarity are immediately entered into the backup table as well as information from new online units. The high-speed bus does not interfere with the remote serial communication link access to any of the upconverters in the chain.
B.2.2 Detachable Modules
Comtech EF Data's upconverters are designed with a detachable Input/Output Module (IOM) which contains the signal path connectors. The IOM is utilized for single thread operation, or for testing of the unit.
For redundant "Daisy Chain" operations, the online upconverters are provided with a detachable
Transmit Switch Module (TSM) replacing the IOM.
Refer to Chapter 3. REAR PANEL CONNECTORS, Sect. 3.2.2.2 for quick reference tables for the modules available to both the UT-4500-A Series Upconverters and the DT-4500-A Series
Downconverters.
B.2.2.1 Upconverter Switching
Upconverter switching is implemented with a detachable TSM. The TSM contains IF and RF transfer switches for input/output looping of the signal. Options for the TSM include Type ‘SMA’ connectors for the RF output signal, and 50 or 75 " BNC connectors for the IF.
B.3 Redundant Configurations
Comtech EF Data UT-4500-A Series Upconverters can be configured in several different redundant subsystem "Daisy Chain" configurations to meet the reliability requirements of a communication system. These configurations include:
! 1:1 Redundant Systems o Single Source IF Input Configuration: The online upconverter uses an IF & RF transfer switch to switch the IF input and RF output signals. A single switched IF input and RF output is provided to and from the online upconverter. The transfer switches are contained in the TSM installed in the online upconverter. When a fault occurs in the online upconverter, the TSM is de-activated to switch out the online upconverter, and switch the IF input and RF output to the backup
upconverter. Figure B-1 depicts the cable connections between the upconverters.
Figure B-2 shows the block diagram of this 1:1 redundant upconverter
configuration. o Dual Source IF Input Configuration: Two IF inputs – IF Input #1 (priority) and IF Input #2 – are switched in the TSM to provide redundant operation of the upconverters. The upconverters provide two switched RF outputs – RF Output #1
(priority) and RF Output #2. If Upconverter #1 faults, Upconverter #2 backs up the priority channel when IF Signal #2 and RF Signal #2 are not operational.
B–2
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
Figure B-5 depicts the cable connections between the upconverters. Figure B-6
shows the block diagram of the 1:1 redundant, dual source RF input, upconverter configuration.
! 1:N Redundant Systems o IF and RF switches in the TSM are used to switch the IF input and RF output of a faulted online upconverter to the backup upconverter. The IF input and RF output to the redundant upconverter subsystem is connected to online upconverter #N.
Figure B-7 depicts the cable connections between the upconverters. Figure B-8
shows the block diagram for this 1:N redundant "Daisy Chain" upconverter configuration.
Figure B-1. 1:1 Redundant Configuration –Single Source IF Input with IOM-XX and TSM-XX
Installed
Figure B-2. 1:1 Redundant Configuration Diagram – Single Source RF Input with IOM-XX
and TSM-XX Installed
B–3
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
Figure B-3. 1:1 Redundant Configuration Diagram – Single Source RF Input with IOM-XX and
TSEQM-XX Installed
Figure B-4. TSEQM Connection Locations
B–4
UT-4500-A Series Upconverters
Appendix B
Figure B-5. 1:1 Redundant Configuration - Dual Source IF Input
Revision 0
MN-UT4500A
Figure B-6. 1:1 Redundant Configuration Diagram – Dual Source IF Input with IOM-XX and
TSM-XX Installed
B–5
UT-4500-A Series Upconverters
Appendix B
Figure B-7. 1:N Redundant Configuration with IOM-XX and TSM-XX Installed
B–6
Revision 0
MN-UT4500A
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
Figure B-8. 1:N Redundant Configuration Diagram with IOM-XX and TSM-XX Installed
B–7
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
B.4 Redundant System Configuration
B.4.1 Initial Configuration
Redundant system configuration is controlled from the upconverter’s front panel configuration menu. Each online unit is assigned a redundancy configuration address. This address is dependent on the location of the online upconverter with reference to the backup. The unit closest to the
backup must be Upconverter # 1. The next unit down must be Upconverter # 2. Figure B-9
shows the appropriate entries for a 1:3 system.
POWER ON
STATUS
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-BU---1:03--
POWER ON
STATUS
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-01----POL-1
POWER ON
STATUS
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-02----POL-1
POWER ON
STATUS
TRANSMIT
REMOTE
ON LINE
FAULT
STORED FAULT
REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-03----POL-1
Figure B-9. Front Panel Displays
Configure the online units first, and then configure the backup unit. Redundant polling starts when the backup is configured. If this polling starts before the online units are configured, a highspeed bus fault will result. This fault should clear when configuration is completed. At this point, control of the redundant system is performed from the backup upconverter.
B–8
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
B.4.2 Automatic Configuration Verification
The backup upconverter has a menu that allows the operator to choose, on a unit-by-unit basis, manual (M) or automatic (A) operating mode.
Figure B-10 shows the system configured for automatic (A) operation. In this mode, failure of an
online upconverter will automatically cause a switchover to the redundant unit to occur. In the field, the simplest way to test this mode is to turn off an online unit. The AUTO/MANUAL
selection is made in the upconverter. The online units will report their status as shown in Figure
Figure B-10. System in Auto Redundant Mode
B–9
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
Figure B-11 depicts the front panel displays after power has been turned off on Upconverter #1.
Note the ON LINE LED is illuminated on the backup upconverter. This indicates that the backup is now providing the frequency translation in place of the online unit. As soon as power is restored, Upconverter #1 will come back online.
Figure B-11. Backup of Converter #1
B–10
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
B.4.3 Manual Configuration and Verification
Figure B-12 shows the system with Upconverter #1 configured for manual (M) operation. In this
mode, the backup upconverter can force switchover of an online unit. This mode also overrides fault status detection of the online units performed by the backup upconverter. If an online unit is configured to manual mode and this unit faults, no switchover will occur.
Figure B-12. Converter #1 in MANUAL, Others in AUTO
B–11
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
Figure B-13 shows the front panel displays after the backup has forced upconverter 1 offline.
Note that the ON LINE LED allows the user to tell whether the backup is currently active and which upconverter is being bypassed.
Figure B-13. Forced Backup of Converter #1
B–12
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
B.4.4 Offset Adjustment
The offset is used to compensate for cable and switch losses. When the system is initially set up and tested, each upconverter needs to be forced to backup and the offset adjusted to minimize gain mismatch between the normal and bypassed mode. This offset will be different for each upconverter and is stored in a table in the backup unit. Follow these steps to set the offset:
Step Description
1
2
3
4
Connect a signal source to the input and a power meter or spectrum analyzer to the output of the first online upconverter.
Record the output power.
Force a backup of the first online unit and adjust the offset until the output power matches what was recorded in Step 2.
Restore the online unit and repeat for the other online units.
B.4.5 Redundancy Systems – Upconverter Removal and Replacement
In a redundancy system, to remove an “inline” upconverter for repair, the following procedure must be used:
Step Description
1
2
3
4
5
Force backup of faulted unit.
Turn the power switch on the inline upconverter rear panel to OFF, and remove the power cord from the upconverter. DO NOT disconnect the RF and IF cables from the TSM.
Unscrew the mounting screws on the TSM first, and then unscrew the rack mounting screws on the front panel of the upconverter.
From the rear of the inline upconverter, hold the TSM and push the upconverter to the front of the rack until
TSM is free of the upconverter chassis.
Remove the inline upconverter from the front of the rack.
To install the replacement unit, the following procedure must be used.
4
5
6
Step Description
1 Power up the new unit on the bench.
2
3
Configure the new unit for the correct redundancy settings (Redundant = ON, Address = match old unit).
Power off the new unit.
Remove existing personality module from the new unit.
Carefully install the new unit into the rack. The existing module in the rack will be plugged into the new unit.
Power up the new unit and un-force the backup.
B–13
UT-4500-A Series Upconverters
Appendix B
Revision 0
MN-UT4500A
To remove a “Backup” upconverter for repair, the following procedure must be used:
Step Description
1
2
3
Turn the power switch on the backup upconverter rear panel to OFF, and remove the power cord from the upconverter. Disconnect the RF and IF cables from the IOM.
Unscrew the rack mounting screws on the front panel of the backup upconverter.
Remove the backup upconverter from the front of the rack.
B–14
Appendix C. MAINTENANCE
AND
TROUBLESHOOTING
C.1 Overview
This appendix serves to assist operator and maintenance personnel in the checkout, maintenance and troubleshooting of the UT-4500-A Series Upconverters.
Comtech EF Data recommends that spare replacement converters be used to replace converters removed from the system for maintenance. Troubleshooting procedures are provided for fault isolation to the module level.
The input and output signals, the interconnecting cables and the location of the modules are as
Figure C-1. Upconverter Signal and Interconnecting Cable Diagram (with Transmit Switch
Module [TSM])
C–1
UT-4500-A Series Upconverters
Appendix C
Revision 0
MN-UT4500A
C.2 Maintenance Testing
The UT-4500-A Series Upconverters translate the input IF frequency from 52 to 88 MHz (or optional 104 to 176 MHz) to an output RF frequency. For example, the RF output frequency of the Model UT-4514-A is 14000 to 14500 MHz. The IF input level is -35 dBm (typical), and the
RF output level is +10 dBm at 1 dB compression.
To prepare for checkout, review the rack mounting information provided in Chapter 2.
INSTALLATION. Operations via the front panel (i.e., use of the menu system, keypad, and
VFD) are explained in detail in Chapter 5. FRONT PANEL OPERATION.
C.2.1 Test Point Samples
The IF output and RF input can be monitored at the RF Sample Test Points on the front panel. A
BNC female connector is provided for the IF sample and a Type ‘SMA’ female connector is provided for the RF output. The RF sample output level is -20 dBc nominal, and the IF sample input level is -20 dBc nominal.
C.2.2 Troubleshooting
Upconverter operating problems can be identified by first observing the LED status indicators on the front panel. When a fault condition is indicated, or and marginal performance tolerance condition exists, the specific fault or faults can be identified via the FAULTS menu branch, accessible via front panel operation. See Sect. 5.3.3 FAULTS in Chapter 5. FRONT PANEL
OPERATION for more information about viewing current or stored faults.
Upconverter operational status screens are available via the MONITOR menu branch. See Sect.
5.3.2 MONITOR in Chapter 5. FRONT PANEL OPERATION for more information.
C.2.3 Upconverter Faults
C.2.3.1 Prime Power
Check the dual fuses on the rear panel. The required prime power is 100 to 125 VAC, or 205 to
240 VAC @ 1 Amp. The optional DC prime power is -48 VDC.
C.2.3.2 DC Power Supply Module
15 VDC: A fault ("FT") indicates a voltage level exceeding $ 10% of the power supply voltage.
Check the output of the DC Power Supply Module. The typical current output level is 3.0 amps.
Check all connections to make sure they are secure. If the voltage exceeds ± 10%, or the power supply module current is not approximately 3.0 amps, or the fault still exists, remove the power supply and return it to Comtech EF Data for repair.
14 VDC: A fault ("FT") indicates a voltage level exceeding ± 10% of the power supply voltage.
The 14 VDC is developed in the modules. Check the output of the 15 VDC Power Supply
C–2
UT-4500-A Series Upconverters
Appendix C
Revision 0
MN-UT4500A
Module, check for other module faults, and check all connections. If the fault still exists, remove the converter and return it to Comtech EF Data for repair.
VCC (+5 VDC): A fault ("FT") indicates a voltage level exceeding ± 10% of the power supply voltage. The 5 VDC is developed in the modules. Check the output of the 15 VDC Power
Supply Module, check for other module faults, and check all connections. If the fault still exists, remove the converter and return it to Comtech EF Data for repair.
C.2.3.3 RF Converter Module
IFLO Lock Detect: A fault (“FT”) indicates that the IFLO is not locked. Check all connections to the converter module to make sure they are secure. If the fault still exists, remove the Converter
Module and return it to Comtech EF Data for repair.
C.2.3.4 Synthesizer Sum Loop Module
Sum Loop Detect: A fault (“FT”) indicates that the sum loop is not locked. Check all connections to the converter module to make sure they are secure. If the fault still exists, remove the Sum Loop Module and return it to Comtech EF Data for repair.
C.2.3.5 Synthesizer Fine Step Module
Coarse Loop Detect: A fault (“FT”) indicates that the coarse loop is not locked. Check all connections to the converter module to make sure they are secure. If the fault still exists, remove the Fine Step Module and return it to Comtech EF Data for repair.
Fine Loop Detect: A fault (“FT”) indicates that the fine loop is not locked. Check all connections to the converter module to make sure they are secure. If the fault still exists, remove the Fine Step
Module and return it to Comtech EF Data for repair.
C.2.3.6 Reference Oscillator Module
Reference Lock Detect: A fault ("FT") indicates that the reference oscillator detected an external reference, but could not lock to it. Disconnect the external reference. If the fault still exists, remove the Reference Module and return it to Comtech EF Data for repair.
C.2.3.7 Temperature Fault
Upconverter Over Temperature Fault: A fault ("FT") indicates that the converter is over temperature. Turn the prime power switch off and return the converter to Comtech EF Data for repair.
C–3
UT-4500-A Series Upconverters
Appendix C
Revision 0
MN-UT4500A
C.2.4 Converter I/O Modules
The Converter I/O Modules (IOM or TSM) are installed into the rear panel of the converter.
IMPORTANT
The thumbscrews used for installing the modules into the converter rear panel are designed to be hand-tightened only. When installing an I/O Module DO
NOT use a screwdriver to tighten the module mounting screws – install screws “hand tight” only.
C.3 Spares
Comtech EF Data recommends field maintenance replacement at the RF converter level, and that the converter is returned to Comtech EF Data for repairs. However, for field replacement of the converter modules, contact Comtech EF Data for the correct spares for and particular converter.
C–4
Temperature
METRIC CONVERSIONS
Units of Length
Foot Yard Mile Unit
1 centimeter
Centimeter
—
1 inch
1 foot
1 yard
1 meter
1 mile
1 mm
1 kilometer
Inch
0.3937
Meter
0.01 0.03281
0.08333
0.01094
0.2778
6.214 x 10 -6
1.578 x 10 -5 2.540
30.480
—
12.0
0.254
0.3048 — 0.3333 1.893 x 10 -4
91.44
100.0
36.0
39.37
3.0
3.281
—
1.094
1.609 x 10 5 6.336 x 10 4 5.280 x 10 3 1.760 x 10 3
5.679 x 10 -4
6.214 x 10 -4
—
0.9144
—
1.609 x 10 3
— 0.03937
—
—
—
—
—
—
0.621
—
— —
Temperature Conversions
% Fahrenheit % Centigrade
Water freezes
Water boils
Absolute 0
32
212
-459.69
0
100
-273.16
Kilometer Millimeter
— —
—
—
—
—
1.609
—
—
Formulas
% C = (F - 32) * 0.555
% F = (C * 1.8) + 32
25.4
—
—
—
—
—
—
Unit
1 gram
Gram
—
Ounce
Avoirdupois
Units of Weight
Ounce
Troy
Pound
Avoirdupois
0.03527 0.03215 0.002205
Pound
Troy
0.002679
Kilogram
0.001
1 oz. avoir. 28.35 — 0.9115 0.0625 0.07595 0.02835
1 oz. troy
1 lb. avoir.
1 lb. Troy
1 kilogram
31.10
453.6
373.2
1.0 x 10 3
1.097
16.0
13.17
35.27
—
14.58
12.0
32.15
0.06857
—
0.8229
2.205
0.08333
1.215
—
2.679
0.03110
0.4536
0.3732
—
2114
WEST
7
TH STREET TEMPE ARIZONA
85281
USA
480 • 333 • 2200
PHONE
480 • 333 • 2161
FAX