© Siemens AG 2007 Overload Relays General data ■ Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 S00 ... S12 S00 ... S12 0.1 ... 630 A 0.3 ... 630 A ( ... 820 A)1) General data Sizes • Are coordinated with the dimensions, connections S00 ... S3 and technical characteristics of the other devices in the SIRIUS modular system (contactors, soft starters, ...) • Permit the mounting of slim and compact load feeders in widths of 45 mm (S00), 45 mm (S0), 55 mm (S2), 70 mm (S3), 120 mm (S6) and 145 mm (S10/S12) Seamless current range • Allows easy and consistent configuration with one 0.11 ... 100 A series of overload relays (for small to large loads) • Simplify configuration Protection functions • Provides optimum inverse-time delayed protection of loads against excessive temperature rises due to overload ✔ ✔ ✔ Tripping in the event of phase unbalance • Provides optimum inverse-time delayed protection of loads against excessive temperature rises due to phase unbalance (✔) ✔ ✔ Tripping in the event of phase failure • Minimizes heating of induction motors during phase failure ✔ ✔ ✔ Protection of single-phase loads • Enables the protection of single-phase loads ✔ -- ✔ Tripping in the event of overheating • Provides optimum temperature-dependent protection of loads against excessive temperature rises, e.g. for stator-critical motors or in the event of insufficient coolant flow, contamination of the motor surface or for long starting or braking operations --2) --2) ✔ -- ✔ (only 3RB21) ✔ ✔ ✔ ✔ ✔ (by means of separate module) ✔ (only 3RB21 with 24 V DC) ✔ by integrated thermistor motor protection function 5 Tripping in the event of overload • Eliminates the need for additional special equipment • Saves space in the control cabinet • Reduces wiring outlay and costs Tripping in the event of a ground fault • Provides optimum protection of loads against high-resistance short-circuits or ground faults due by to moisture, condensed water, damage to the insulation material, etc. internal ground fault detection • Eliminates the need for additional special (activatable) equipment. • Saves space in the control cabinet • Reduces wiring outlay and costs Features RESET function • Allows manual or automatic resetting of the relay Remote RESET function • Allows the remote resetting of the relay TEST function for auxiliary contacts • Allows easy checking of the function and wiring ✔ ✔ ✔ TEST function for electronics • Allows checking of the electronics -- ✔ ✔ Status display • Displays the current operating status ✔ ✔ ✔ Large current adjustment button • Makes it easier to set the relay exactly to the correct current value ✔ ✔ ✔ Integrated auxiliary contacts (1 NO + 1 NC) • Allows the load to be switched off if necessary • Can be used to output signals ✔ ✔ ✔ (2 ×) 1) Motor currents up to 820 A can be recorded and evaluated by a current measuring module, e.g. 3RB29 06-2BG1 (0.3 ... 3 A) , in combination with a 3UF18 68-3GA00 (820 A / 1 A) series transformer. 2) The SIRIUS 3RN thermistor motor protection devices can be used to provide additional protection temperature-dependent protection. Siemens LV 1 · 2007 5/31 © Siemens AG 2007 Overload Relays General data Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Design of load feeders Short-circuit strength up to 100 kA • Provides optimum protection of the loads and opat 690 V erating personnel in the event of short-circuits due (in conjunction with the corresponding to insulation faults or faulty switching operations fuses or the corresponding motor starter protector) Electrical and mechanical matching to 3RT1 contactors • Simplifies configuration ✔ ✔ ✔ ✔ ✔ ✔1) -- ✔ (S2 ... S6) ✔ (S00 ... S6) ✔ (S00) -- -- ✔ ✔ ✔ ✔ ✔ ✔ (✔) ✔ ✔ -- ✔ (1:4) ✔ (1:10) -- ✔ (only 3RB21) ✔ • Reduces wiring outlay and costs 5 • Enables stand-alone installation as well as space-saving direct mounting Straight-through transformers for main circuit2) (in this case the cables are routed through the feed-through openings of the overload relay and connected directly to the box terminals of the contactor) • Reduces the contact resistance (only one point of contact) Spring-loaded terminal connection system for main circuit2) • Enables fast connections • Saves wiring costs (easy, no need for tools, and fast). • Saves material costs • Reduces installation costs • Permits vibration-resistant connections • Enables maintenance-free connections Spring-loaded terminal connection system for auxiliary circuits2) • Enables fast connections • Permits vibration-resistant connections • Enables maintenance-free connections Other features Temperature compensation • Allows the use of the relays at high temperatures without derating • Prevents premature tripping • Allows compact installation of the control cabinet without distance between the units/load feeders • Simplifies configuration • Enables space to be saved in the control cabinet Very high long-term stability • Provides safe protection for the loads even after years of use in severe operating conditions Wide setting ranges • Reduce the number of variants • Minimize the engineering outlay and costs • Minimize storage overhead, storage costs, tied-up capital Trip class CLASS 5 • Enables solutions for very fast starting motors requiring special protection (e.g. Ex motors) Trip class > CLASS 10 • Enable heavy starting solutions -- ✔ ✔ Low power loss • Reduces power consumption and energy costs (up 98 % less power is used than for thermal overload relays). -- ✔ ✔ • Minimizes temperature rises of the contactor and control cabinet – in some cases this may eliminate the need for control cabinet cooling. • Direct mounting to contactor saves space, even for high motor currents (i.e. no heat decoupling is required). 1) 2) Exception: up to size S3, only stand-alone installation is possible. Alternatively available for screw terminals. 5/32 Siemens LV 1 · 2007 © Siemens AG 2007 Overload Relays General data Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Other features Internal power supply • Eliminates the need for configuration and connecting an additional control circuit Variable adjustment of the trip classes • Reduces the number of variants Overload warning • Indicates imminent tripping of the relay directly on the device due to overload, phase unbalance or phase failure --1) ✔ -- -- ✔ (only 3RB21) ✔ -- -- ✔ -- -- ✔ • Minimizes the configuring outlay and costs (The required trip class can be adjusted • Minimizes storage overhead, storage costs, and by means of a rotary switch depending tied-up capital on the current start-up condition.) • Allows the imminent tripping of the relay to be signaled • Allows measures to be taken in time in the event of continuous inverse-time delayed overloads • Eliminates the need for an additional device 5 • Saves space in the control cabinet • Reduces wiring outlay and costs Analog output • Allows the output of an analog output signal for actuating moving-coil instruments, feeding programmable logic controllers or transfer to bus systems • Eliminates the need for an additional measuring transformer and signal converter • Saves space in the control cabinet • Reduces wiring outlay and costs 1) The SIRIUS 3RU11 thermal overload relays use a bimetal contactor and therefore do not require a control supply voltage. Siemens LV 1 · 2007 5/33 © Siemens AG 2007 Overload Relays General data Overload relays Current measurement Type Type Current range A Contactors (type, size, rating in kW) 3RT10 1 3RT10 2 3RT10 3 3RT10 4 3RT10 5 3RT10 6 3RT10 7 S00 S0 S2 S3 S6 S10 S12 3/4/5.5 5.5/7.5/11 15/18.5/22 30/37/45 55/75/90 110/132/160 200/250 3TF68/69 Size 14 375/450 3RU11 thermal overload relays 3RU11 1 integrated 0.11 … 12 ✔ -- -- -- -- -- -- -- 3RU11 2 integrated 1.8 … 25 -- ✔ -- -- -- -- -- -- 3RU11 3 integrated 5.5 … 50 -- -- ✔ -- -- -- -- -- 3RU11 4 integrated 18 … 100 -- -- -- ✔ -- -- -- -- 3RB20/3RB211) solid-state overload relays 3RB2. 1 integrated 0.1 … 12 ✔ -- -- -- -- -- -- -- 3RB20 2 3RB21 2 integrated integrated 3 … 25 1 … 25 --- ✔ ✔ --- --- --- --- --- --- 3RB2. 3 integrated 6 … 50 -- -- ✔ -- -- -- -- -- 3RB2. 4 integrated 12.5 … 100 -- -- -- ✔ -- -- -- -- 3RB2. 5 integrated 50 ... 200 -- -- -- -- ✔ -- -- -- 3RB2. 6 integrated 55 ... 630 -- -- -- -- -- ✔ ✔ ✔ 3RB29 0 0.3 … 25 ✔ ✔ -- -- -- -- -- -- 3RB29 0 10 ... 100 -- -- ✔ ✔ -- -- -- -- 3RB22/3RB23 + 3RB29 5 20 … 200 -- -- -- -- ✔ -- -- -- 3RB29 6 63 ... 630 -- -- -- -- -- ✔ ✔ ✔ 3RB29 0 + 3UF18 630 ... 820 -- -- -- -- -- -- -- ✔ 5 3RB22/3RB231) solid-state overload relays 1) When using the overload relays with trip class ≥ CLASS 20, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders and the configuring aid "Configuring SIRIUS Fuseless Load Feeders". 5/34 Siemens LV 1 · 2007 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications ■ Overview The 3RB20 and 3RB21 solid-state overload relays up to 630 A with internal power supply have been designed for inverse-time delayed protection of loads with normal and heavy starting (see LV 1 T, Function) against excessive temperature rises due to overload, phase unbalance or phase failure. An overload, phase unbalance or phase failure result in an increase of the motor current beyond the set motor rated current. This current rise is detected by the current transformers integrated into the devices and evaluated by corresponding solid-state circuits which then output a pulse to the auxiliary contacts. The auxiliary contacts then switch off the load by means of a contactor. The break time depends on the ratio between the tripping current and set current Ie and is stored in the form of a long-term stable tripping characteristic (see LV 1 T Characteristic Curves). The "tripped" status is signaled by means of a switch position indicator (see LV 1 T, Function). Resetting takes place either manually or automatically after the recovery time has elapsed (see LV 1 T, Function). The devices are manufactured in accordance with environmental guidelines and contain environmentally friendly and reusable materials. They comply with all important worldwide standards and approvals. ■ Benefits The most important features and benefits of the 3RB20/3RB21 solid-state overload relays are listed in the overview table (see Overload Relays, General Data). Siemens LV 1 · 2007 5/35 5 (1) Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting pins can be used for direct mounting of the overload relays. Stand-alone installation is possible as an alternative (in some cases in conjunction with a stand-alone installation module). (2) Selector switch for manual/automatic RESET and RESET button: With the slide switch you can choose between manual and automatic RESET. A device set to manual RESET can be reset locally by pressing the RESET button. On the 3RB21 a solid-state remote RESET is integrated. (3) Switch position indicator and TEST function of the wiring: Indicates a trip and enables the wiring test. (4) Solid-state test (device test): Enables a test of all important device components and functions. (5) Motor current setting: Setting the device to the motor rated current is easy with the large rotary knob. (6) Trip class setting/internal ground-fault detection (only 3RB21): Using the rotary switch you can set the required trip class and activate the internal ground-fault detection dependent on the start-up conditions. (7) Connecting terminals (removable terminal block for auxiliary circuits): The generously sized terminals permit connection of two conductors with different cross-sections for the main and auxiliary circuits. The auxiliary circuit can be connected with screw connection and alternatively with spring-type connection. In addition to inverse-time delayed protection of loads against excessive temperature rises due to overload, phase unbalance and phase failure, the 3RB21 solid-state overload relays also allow internal ground-fault detection (not possible in conjunction with wye-delta assemblies). This provides protection of loads against high-resistance short-circuits due to damage to the insulation material, moisture, condensed water etc. © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications ■ Application "Increased safety" type of protection EEx e according to ATEX directive 94/9/EC Industries The 3RB20/3RB21 solid-state overload relays are suitable for customers from all industries who want to guarantee optimum inverse-time delayed protection of their electrical loads (e.g. motors) under normal and heavy starting conditions (CLASS 5 to CLASS 30), minimize project completion times, inventories and power consumption, and optimize plant availability and maintenance management. Application The 3RB20/3RB21 solid-state overload relays have been designed for the protection of induction motors in sinusoidal 50/60 Hz voltage networks. The relays are not suitable for the protection of single-phase AC or DC loads. The 3RU11 thermal overload relay or the 3RB22/3RB23 solidstate overload relay can be used for single-phase AC loads. For DC loads we recommend the 3RU11 thermal overload relay. Ambient conditions The devices are insensitive to external influences such as shocks, corrosive environments, ageing and temperature fluctuation. 5 For the temperature range from –25 C to +60 °C, the 3RB20/3RB21 solid-state overload relays compensate the temperature according to IEC 60947-4-1. For the 3RB20/3RB21 solid-state overload relays with the sizes S6, S10 and S12, the upper set value of the setting range must be reduced for ambient temperatures > 50 °C by a certain factor (see tables below). Type Setting range Derating factor for the upper set value for stand-alone installation at ambient temperature +50 °C +60 °C 3RB20 56/3RB21 56 50 ... 200 A 100 % 100 % 3RB20 66/3RB21 66 55 ... 250 A 100 % 100 % 3RB20 66/3RB21 66 160 ... 630 A 100 % 90 % Type Setting range Derating factor for the upper set value for mounting onto contactor at ambient temperature +50 °C +60 °C 3RB20 56/3RB21 56 50 ... 200 A 100 % 70 % 3RB20 66/3RB21 66 55 ... 250 A 100 % 70 % 3RB20 66/3RB21 66 160 ... 630 A 100 % 70 % 5/36 Siemens LV 1 · 2007 The 3RB20/3RB21 solid-state overload relays are suitable for the overload protection of explosion-proof motors with "increased safety" type of protection EEx e. The relays meet the requirements of EN 60079-7 (Electrical apparatus for potentially explosive atmospheres – Increased safety "e"). The basic safety and health requirements of ATEX directive 94/9/EC are fulfilled by compliance with • EN 60947-1 • EN 60947-4-1 • EN 60947-5-1 • EN 60079-14 EU type test certificate for Group II, Category (2) G/D exists. ■ Accessories The following accessories are available for the 3RB20/3RB21 solid-state overload relays: • One terminal bracket each for the overload relays size S00 and S0 (sizes S2 to S12 can be installed as single units without a terminal bracket) • One mechanical remote RESET module for all sizes • One cable release for resetting devices which are difficult to access (for all sizes) • One sealable cover for all sizes • Box terminal blocks for sizes S6 and S10/S12 • Terminal covers for sizes S2 to S10/S12 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications ■ Selection and ordering data Conversion aid 3RB10 ––> 3RB20 Size Previous type Replacement type 3RB10 Setting range in A 3RB20 Setting range in A 3RB10 [email protected] 0.1 ... 0.4 3RB20 [email protected] 0.1 ... 0.4 3RB10 [email protected] 0.4 ... 1.6 3RB20 [email protected] 0.32 ... 1.25 3RB20 [email protected] 1 ... 4 3RB10 [email protected] 1.5 ... 6 3RB10 [email protected] 3 3RB20 [email protected] 3 ... 12 3RB10 [email protected] 0.1 ... 0.4 3RB10 [email protected] 0.4 ... 1.6 3RB10 [email protected] 1.5 ... 6 3RB10 [email protected] 3 ... 12 3RB20 [email protected] 3RB10 [email protected] 6 ... 25 3RB20 [email protected] 6 ... 25 3RB10 [email protected] 6 ... 25 3RB20 [email protected] 6 ... 25 3RB10 [email protected] 13 ... 50 3RB20 [email protected] 12.5 ... 50 3RB10 [email protected] 13 ... 50 3RB20 [email protected] 12.5 ... 50 3RB10 [email protected] 25 ... 100 3RB20 [email protected] 25 ... 100 S00 S0 S2 S3 S6 3RB10 [email protected] 50 ... 200 3RB10 [email protected] 55 ... 250 3RB10 [email protected] 200 ... 540 3RB10 [email protected] 300 ... 630 Use size S00 3RB20 [email protected] 3RB20 [email protected] 3 ... 12 50 ... 200 3RB20 [email protected] 55 ... 250 3RB20 [email protected] 160 ... 630 5 S10/S12 3RB10 [email protected] ... 12 CLASS 10 1 1 CLASS 20 2 2 Conversion aid 3RB10 ––> 3RB21 Size Previous type Replacement type 3RB10 Setting range in A 3RB21 Setting range in A 3RB10 [email protected] 0.1 ... 0.4 3RB21 13-4RB0 0.1 ... 0.4 3RB10 [email protected] 0.4 ... 1.6 3RB21 13-4NB0 0.32 ... 1.25 3RB21 13-4PB0 1 ... 4 3RB10 [email protected] 1.5 ... 6 3RB10 [email protected] 3 3RB21 13-4SB0 3 ... 12 3RB10 [email protected] 0.1 ... 0.4 3RB10 [email protected] 0.4 ... 1.6 3RB10 [email protected] 1.5 ... 6 3RB21 23-4PB0 1 ... 4 3RB10 [email protected] 3 ... 12 3RB21 23-4SB0 3 ... 12 3RB10 [email protected] 6 ... 25 3RB21 23-4QB0 6 ... 25 3RB10 [email protected] 6 ... 25 3RB21 33-4QB0 6 ... 25 3RB10 [email protected] 13 ... 50 3RB21 33-4UB0 12.5 ... 50 3RB10 [email protected] 13 ... 50 3RB21 43-4UB0 12.5 ... 50 3RB10 [email protected] 25 ... 100 3RB21 43-4EB0 25 ... 100 S00 S0 S2 S3 S6 S10/S12 3RB10 [email protected] 3RB10 [email protected] ... 12 50 ... 200 3RB10 [email protected] 55 ... 250 3RB10 [email protected] 200 ... 540 3RB10 [email protected] 300 ... 630 Use size S00 3RB21 53-4FW2 3RB21 53-4FC2 3RB21 63-4GC2 3RB21 63-4MC2 50 ... 200 55 ... 250 160 ... 630 Note: CLASS 10 1 CLASS 20 2 CLASS 5, 10, 20 and 30 can be adjusted on the unit Siemens LV 1 · 2007 5/37 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications 3RB20 solid-state overload relays with screw terminals on auxiliary current side for direct mounting1)2) and stand-alone installation2)3), CLASS 10 Features and technical specifications: • Overload protection, phase failure protection and unbalance protection • Internal power supply • Auxiliary contacts 1 NO + 1 NC Size of Rating contactor for induction 4) motor Rated value5) kW • Manual and automatic RESET • Switch position indicator • TEST function and self-monitoring Set current value of the inversetime delayed overload release Short-circuit DT Screw terminals protection (on auxiliary current side) with fuse, type of coorOrder No. Price dination 2, per PU gL/gG operational class6) A A PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Size S001) S00 0.04 … 0.09 0.1 … 0.4 1 } 3RB20 16-1RB0 1 1 unit 101 0.200 0.12 … 0.37 0.32 … 1.25 2 } 3RB20 16-1NB0 1 1 unit 101 0.200 0.55 … 1.5 1…4 10 } 3RB20 16-1PB0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 } 3RB20 16-1SB0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 } 3RB20 26-1SB0 1 1 unit 101 0.220 3 … 11 6 … 25 35 } 3RB20 26-1QB0 1 1 unit 101 0.220 3 … 11 6 … 25 63 0.360 3RB20 16-1RB0 Size S01) 5 S0 3RB20 26-1QB0 Size S21)3)7) S2 7.5 … 22 12.5 … 50 80 } 3RB20 36-1QB0 1 1 unit 101 } 3RB20 36-1QW1 1 1 unit 101 0.230 } 3RB20 36-1UB0 1 1 unit 101 0.360 } 3RB20 36-1UW1 1 1 unit 101 0.230 3RB20 36-1UB0 Size S31)3)7) S3 7.5 … 22 12.5 … 50 160 } 3RB20 46-1UB0 1 1 unit 101 0.560 11 … 45 25 … 100 315 } 3RB20 46-1EB0 1 1 unit 101 0.560 } 3RB20 46-1EW1 1 1 unit 101 0.450 } 3RB20 56-1FC2 1 1 unit 101 1.030 } 3RB20 56-1FW2 1 1 unit 101 0.690 3RB20 46-1EB0 Size S6 2)7) S6 with bar connection 22 … 90 50 … 200 315 S6 with box terminals 3RB20 56-1FW2 Size S10/S122) S10/S12 and size 14 (3TF68/ 3TF69) 22 … 110 55 … 250 400 } 3RB20 66-1GC2 1 1 unit 101 1.820 90 … 450 160 … 630 800 } 3RB20 66-1MC2 1 1 unit 101 1.820 3RB20 66-1MC2 1) The relays with an Order No. ending with "0" are designed for direct mounting. With the matching terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units. 5) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. 2) The relays with an Order No. ending with "2" are designed for direct mounting and stand-alone installation. For 3TF68/3TF69 contactors, direct mounting is not possible. 6) Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders. 3) The relays with an Order No. ending with "1" are designed for stand-alone installation. Observe maximum rated operational current of the devices. 7) The relays with an Order No. with "W" in penultimate position are equipped with a straight-through transformer. 4) * You can order this quantity or a multiple thereof. 5/38 Siemens LV 1 · 2007 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications 3RB20 solid-state overload relays with spring-loaded terminals on auxiliary current side for direct mounting1)2) and stand-alone installation2)3), CLASS 10 Features and technical specifications: • Overload protection, phase failure protection and unbalance protection • Internal power supply • Auxiliary contacts 1 NO + 1 NC Size of Rating contactor for induction 4) motor Rated value5) kW • Manual and automatic RESET • Switch position indicator • TEST function and self-monitoring Set current value of the inversetime delayed overload release Short-circuit DT Spring-loaded terminals protection (on auxiliary current side) with fuse, type of coorOrder No. Price dination 2, per PU gL/gG operational class6) A A PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Size S001) S00 0.04 … 0.09 0.1 … 0.4 1 A 3RB20 16-1RD0 1 1 unit 101 0.200 0.12 … 0.37 0.32 … 1.25 2 A 3RB20 16-1ND0 1 1 unit 101 0.200 0.55 … 1.5 1…4 10 A 3RB20 16-1PD0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 A 3RB20 16-1SD0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 A 3RB20 26-1SD0 1 1 unit 101 0.220 3 … 11 6 … 25 35 A 3RB20 26-1QD0 1 1 unit 101 0.220 3 … 11 6 … 25 63 0.360 3RB20 16-1RD0 Size S01) 5 S0 3RB20 26-1QD0 Size S21)3)7) S2 7.5 … 22 12.5 … 50 80 A 3RB20 36-1QD0 1 1 unit 101 A 3RB20 36-1QX1 1 1 unit 101 0.230 A 3RB20 36-1UD0 1 1 unit 101 0.360 A 3RB20 36-1UX1 1 1 unit 101 0.230 3RB20 36-1UD0 Size S31)3)7) S3 7.5 … 22 12.5 … 50 160 A 3RB20 46-1UD0 1 1 unit 101 0.560 11 … 45 25 … 100 315 A 3RB20 46-1ED0 1 1 unit 101 0.560 A 3RB20 46-1EX1 1 1 unit 101 0.450 A 3RB20 56-1FF2 1 1 unit 101 1.030 A 3RB20 56-1FX2 1 1 unit 101 0.690 3RB20 46-1ED0 Size S6 2)7) S6 with bar connection 22 … 90 50 … 200 315 S6 with box terminals 3RB20 56-1FX2 Size S10/S122) S10/S12 and size 14 (3TF68/ 3TF69) 22 … 110 55 … 250 400 A 3RB20 66-1GF2 1 1 unit 101 1.820 90 … 450 160 … 630 800 A 3RB20 66-1MF2 1 1 unit 101 1.820 3RB20 66-1MF2 1) The relays with an Order No. ending with "0" are designed for direct mounting. With the matching terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units. 5) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. 2) The relays with an Order No. ending with "2" are designed for direct mounting and stand-alone installation. For 3TF68/3TF69 contactors, direct mounting is not possible. 6) Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders. 3) The relays with an Order No. ending with "1" are designed for stand-alone installation. Observe maximum rated operational current of the devices. 7) The relays with an Order No. with "X" in penultimate position are equipped with a straight-through transformer. 4) * You can order this quantity or a multiple thereof. Siemens LV 1 · 2007 5/39 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications 3RB20 solid-state overload relays with screw terminals on auxiliary current side for direct mounting1)2) and stand-alone installation2)3), CLASS 20 Features and technical specifications: • Overload protection, phase failure protection and unbalance protection • Internal power supply • Auxiliary contacts 1 NO + 1 NC Size of Rating contactor for induction 4) motor Rated value5) kW • Manual and automatic RESET • Switch position indicator • TEST function and self-monitoring Set current value of the inversetime delayed overload release Short-circuit DT Screw terminals protection (on auxiliary current side) with fuse, type of coorOrder No. Price dination 2, per PU gL/gG operational class6) A A PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Size S001) S00 0.04 … 0.09 0.1 … 0.4 1 } 3RB20 16-2RB0 1 1 unit 101 0.200 0.12 … 0.37 0.32 … 1.25 2 } 3RB20 16-2NB0 1 1 unit 101 0.200 0.55 … 1.5 1…4 10 } 3RB20 16-2PB0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 } 3RB20 16-2SB0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 } 3RB20 26-2SB0 1 1 unit 101 0.220 3 … 11 6 … 25 35 } 3RB20 26-2QB0 1 1 unit 101 0.220 3 … 11 6 … 25 63 0.360 3RB20 16-2RB0 Size S01) 5 S0 3RB20 26-2QB0 Size S21)3)7) S2 7.5 … 22 12.5 … 50 80 } 3RB20 36-2QB0 1 1 unit 101 } 3RB20 36-2QW1 1 1 unit 101 0.230 } 3RB20 36-2UB0 1 1 unit 101 0.360 } 3RB20 36-2UW1 1 1 unit 101 0.230 3RB20 36-2UB0 Size S31)3)7) S3 7.5 … 22 12.5 … 50 160 } 3RB20 46-2UB0 1 1 unit 101 0.560 11 … 45 25 … 100 315 } 3RB20 46-2EB0 1 1 unit 101 0.560 } 3RB20 46-2EW1 1 1 unit 101 0.450 } 3RB20 56-2FC2 1 1 unit 101 1.030 } 3RB20 56-2FW2 1 1 unit 101 0.690 3RB20 46-2EB0 Size S6 2)7) S6 with bar connection 22 … 90 50 … 200 315 S6 with box terminals 3RB20 56-2FW2 Size S10/S122) S10/S12 and size 14 (3TF68/ 3TF69) 22 … 110 55 … 250 400 } 3RB20 66-2GC2 1 1 unit 101 1.820 90 … 450 160 … 630 800 } 3RB20 66-2MC2 1 1 unit 101 1.820 3RB20 66-2MC2 1) The relays with an Order No. ending with "0" are designed for direct mounting. With the matching terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units. 5) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. 2) The relays with an Order No. ending with "2" are designed for direct mounting and stand-alone installation. For 3TF68/3TF69 contactors, direct mounting is not possible. 6) Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders. 3) The relays with an Order No. ending with "1" are designed for stand-alone installation. Observe maximum rated operational current of the devices. 7) The relays with an Order No. with "W" in penultimate position are equipped with a straight-through transformer. 4) * You can order this quantity or a multiple thereof. 5/40 Siemens LV 1 · 2007 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications 3RB20 solid-state overload relays with spring-loaded terminals on auxiliary current side for direct mounting1)2) and stand-alone installation2)3), CLASS 20 Features and technical specifications: • Overload protection, phase failure protection and unbalance protection • Internal power supply • Auxiliary contacts 1 NO + 1 NC Size of Rating contactor for induction 4) motor Rated value5) kW • Manual and automatic RESET • Switch position indicator • TEST function and self-monitoring Set current value of the inversetime delayed overload release Short-circuit DT Spring-loaded terminals protection (on auxiliary current side) with fuse, type of coorOrder No. Price dination 2, per PU gL/gG operational class6) A A PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Size S001) S00 0.04 … 0.09 0.1 … 0.4 1 A 3RB20 16-2RD0 1 1 unit 101 0.200 0.12 … 0.37 0.32 … 1.25 2 A 3RB20 16-2ND0 1 1 unit 101 0.200 0.55 … 1.5 1…4 10 A 3RB20 16-2PD0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 A 3RB20 16-2SD0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 A 3RB20 26-2SD0 1 1 unit 101 0.220 3 … 11 6 … 25 35 A 3RB20 26-2QD0 1 1 unit 101 0.220 3 … 11 6 … 25 63 0.360 3RB20 16-2RD0 Size S01) 5 S0 3RB20 26-2QD0 Size S21)3)7) S2 7.5 … 22 12.5 … 50 80 A 3RB20 36-2QD0 1 1 unit 101 A 3RB20 36-2QX1 1 1 unit 101 0.230 A 3RB20 36-2UD0 1 1 unit 101 0.360 A 3RB20 36-2UX1 1 1 unit 101 0.230 3RB20 36-2UD0 Size S31)3)7) S3 7.5 … 22 12.5 … 50 160 A 3RB20 46-2UD0 1 1 unit 101 0.560 11 … 45 25 … 100 315 A 3RB20 46-2ED0 1 1 unit 101 0.560 A 3RB20 46-2EX1 1 1 unit 101 0.450 A 3RB20 56-2FF2 1 1 unit 101 1.030 A 3RB20 56-2FX2 1 1 unit 101 0.690 3RB20 46-2ED0 Size S6 2)7) S6 with bar connection 3RB20 56-2FX2 22 … 90 50 … 200 315 S6 with box terminals Size S10/S122) S10/S12 and size 14 (3TF68/ 3TF69) 22 … 110 55 … 250 400 A 3RB20 66-2GF2 1 1 unit 101 1.820 90 … 450 160 … 630 800 A 3RB20 66-2MF2 1 1 unit 101 1.820 3RB20 66-2MF2 1) 2) 3) 4) The relays with an Order No. ending with "0" are designed for direct mounting. With the matching terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units. The relays with an Order No. ending with "2" are designed for direct mounting and stand-alone installation. For 3TF68/3TF69 contactors, direct mounting is not possible. The relays with an Order No. ending with "1" are designed for stand-alone installation. 5) 6) 7) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders. The relays with an Order No. with "X" in penultimate position are equipped with a straight-through transformer. Observe maximum rated operational current of the devices. * You can order this quantity or a multiple thereof. Siemens LV 1 · 2007 5/41 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications 3RB21 solid-state overload relays with screw terminals on auxiliary current side for direct mounting1)2) and stand-alone installation2)3), CLASS 5, 10, 20 and 30 adjustable Features and technical specifications: • Overload protection, phase failure protection and unbalance protection • Internal ground fault detection (activatable) • Internal power supply • Auxiliary contacts 1 NO + 1 NC Size of Rating for contactor induction motor 4) Rated value5) kW • • • • Manual and automatic RESET Electrical remote RESET integrated Switch position indicator TEST function and self-monitoring Set current value of the inversetime delayed overload release Short-circuit DT Screw terminals protection (on auxiliary current side) with fuse, type of coorOrder No. Price dination 2, per PU gL/gG operational class6) A A PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Size S001) S00 0.04 … 0.09 0.1 … 0.4 1 } 3RB21 13-4RB0 1 1 unit 101 0.200 0.12 … 0.37 0.32 … 1.25 2 } 3RB21 13-4NB0 1 1 unit 101 0.200 0.55 … 1.5 1…4 10 } 3RB21 13-4PB0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 } 3RB21 13-4SB0 1 1 unit 101 0.200 0.220 3RB21 13-4RB0 Size S01) 0.55 ... 1.5 1 ... 4 10 } 3RB21 23-4PB0 1 1 unit 101 1.1 … 5.5 3 … 12 20 } 3RB21 23-4SB0 1 1 unit 101 0.220 3 … 11 6 … 25 35 } 3RB21 23-4QB0 1 1 unit 101 0.220 3 … 11 6 … 25 35 0.360 5 S0 3RB21 23-4QB0 Size S21)3)7) S2 7.5 … 22 12.5 … 50 100 } 3RB21 33-4QB0 1 1 unit 101 } 3RB21 33-4QW1 1 1 unit 101 0.230 } 3RB21 33-4UB0 1 1 unit 101 0.360 } 3RB21 33-4UW1 1 1 unit 101 0.230 3RB21 33-4UB0 Size S31)3)7) S3 7.5 … 22 12.5 … 50 125 } 3RB21 43-4UB0 1 1 unit 101 0.560 11 … 45 25 … 100 200 } 3RB21 43-4EB0 1 1 unit 101 0.560 } 3RB21 43-4EW1 1 1 unit 101 0.450 } 3RB21 53-4FC2 1 1 unit 101 1.030 } 3RB21 53-4FW2 1 1 unit 101 0.690 3RB21 43-4EB0 Size S6 2)7) S6 with bar connection 22 … 90 50 … 200 355 S6 with box terminals 3RB21 53-4FC2 Size S10/S122) S10/S12 and size 14 (3TF68/ 3TF69) 22 … 110 55 … 250 500 } 3RB21 63-4GC2 1 1 unit 101 1.820 90 … 450 160 … 630 800 } 3RB21 63-4MC2 1 1 unit 101 1.820 3RB21 63-4MC2 1) The relays with an Order No. ending with "0" are designed for direct mounting. With the matching terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units. 5) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. 2) The relays with an Order No. ending with "2" are designed for direct mounting and stand-alone installation. For 3TF68/3TF69 contactors, direct mounting is not possible. 6) Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders. 3) The relays with an Order No. ending with "1" are designed for stand-alone installation. 7) The relays with an Order No. with "W" in penultimate position are equipped with a straight-through transformer. 4) Observe maximum rated operational current of the devices. * You can order this quantity or a multiple thereof. 5/42 Siemens LV 1 · 2007 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB20, 3RB21 for standard applications 3RB21 solid-state overload relays with spring-loaded terminals on auxiliary current side for direct mounting1)2) and stand-alone installation1)3), CLASS 5, 10, 20 and 30 adjustable Features and technical specifications: • Overload protection, phase failure protection and unbalance protection • Internal ground fault detection (activatable) • Internal power supply • Auxiliary contacts 1 NO + 1 NC Size of Rating contactor for induction 4) motor Rated value5) kW • • • • Manual and automatic RESET Electrical remote RESET integrated Switch position indicator TEST function and self-monitoring Set current value of the inversetime delayed overload release Short-circuit DT Spring-loaded terminals protection (on auxiliary current side) with fuse, type of coorOrder No. Price dination 2, per PU gL/gG operational class6) A A PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Size S001) S00 0.04 … 0.09 0.1 … 0.4 1 A 3RB21 13-4RD0 1 1 unit 101 0.200 0.12 … 0.37 0.32 … 1.25 2 A 3RB21 13-4ND0 1 1 unit 101 0.200 0.55 … 1.5 1…4 10 A 3RB21 13-4PD0 1 1 unit 101 0.200 1.1 … 5.5 3 … 12 20 A 3RB21 13-4SD0 1 1 unit 101 0.200 0.220 3RB21 13-4RD0 Size S01) 0.55 ... 1.5 1 ... 4 10 A 3RB21 23-4PD0 1 1 unit 101 1.1 … 5.5 3 … 12 20 A 3RB21 23-4SD0 1 1 unit 101 0.220 3 … 11 6 … 25 35 A 3RB21 23-4QD0 1 1 unit 101 0.220 3 … 11 6 … 25 35 0.360 5 S0 3RB21 23-4QD0 Size S21)3)7) S2 7.5 … 22 12.5 … 50 100 A 3RB21 33-4QD0 1 1 unit 101 A 3RB21 33-4QX1 1 1 unit 101 0.230 A 3RB21 33-4UD0 1 1 unit 101 0.360 A 3RB21 33-4UX1 1 1 unit 101 0.230 3RB21 33-4UD0 Size S31)3)7) S3 7.5 … 22 12.5 … 50 125 A 3RB21 43-4UD0 1 1 unit 101 0.560 11 … 45 25 … 100 200 A 3RB21 43-4ED0 1 1 unit 101 0.560 A 3RB21 43-4EX1 1 1 unit 101 0.450 A 3RB21 53-4FF2 1 1 unit 101 1.030 A 3RB21 53-4FX2 1 1 unit 101 0.690 3RB21 43-4ED0 Size S6 2)7) S6 with bar connection 22 … 90 50 … 200 355 S6 with box terminals 3RB21 53-4FX2 Size S10/S122) S10/S12 and size 14 (3TF68/ 3TF69) 22 … 110 55 … 250 500 A 3RB21 63-4GF2 1 1 unit 101 1.820 90 … 450 160 … 630 800 A 3RB21 63-4MF2 1 1 unit 101 1.820 3RB21 63-4MF2 1) 2) 3) 4) The relays with an Order No. ending with "0" are designed for direct mounting. With the matching terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units. The relays with an Order No. ending with "2" are designed for direct mounting and stand-alone installation. For 3TF68/3TF69 contactors, direct mounting is not possible. The relays with an Order No. ending with "1" are designed for stand-alone installation. 5) 6) 7) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders. The relays with an Order No. with "X" in penultimate position are equipped with a straight-through transformer. Observe maximum rated operational current of the devices. * You can order this quantity or a multiple thereof. Siemens LV 1 · 2007 5/43 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB22, 3RB23 for high-feature applications ■ Overview 5 The modular, solid-state overload relays with external power supply type 3RB22 (with monostable auxiliary contacts) and type 3RB23 (with bistable auxiliary contacts) up to 630 A (up to 820 A possible with a series transformer) have been designed for inverse-time delayed protection of loads with normal and heavy starting (see LV 1 T, Function) against excessive temperature rises due to overload, phase unbalance or phase failure. An overload, phase unbalance or phase failure result in an increase of the motor current beyond the set motor rated current. This current rise is detected by means of a current measuring module and electronically evaluated by a special evaluation module which is connected to it. The evaluation electronics sends a signal to the auxiliary contacts. The auxiliary contacts then switch off the load by means of a contactor. The break time depends on the ratio between the tripping current and set current Ie and is stored in the form of a long-term stable tripping characteristic (see LV 1 T, Characteristic Curves). The "tripped" status is signaled by means of a continuous red "OVERLOAD" LED. 3RB22/3RB23 evaluation module (1) Green "READY" LED: A continuous green light signals that the device is working correctly. (2) Red "GND FAULT" LED A continuous red light signals a ground-fault tripping. (3) Red "THERMISTOR" LED: A continuous red light signals an active thermistor trip. (4) Red "OVERLOAD" LED: A continuous red light signals an active overload trip; a flickering red light signals an imminent trip (overload warning). (5) Motor current and trip class adjustment: Setting the device to the motor current and to the required trip class dependent on the start-up conditions is easy with the two rotary switches. (6) Selector switch for manual/automatic RESET: With this switch you can choose between manual and automatic RESET. (7) Test/RESET button: Enables testing of all important device components and functions, plus resetting of the device after a trip when manual RESET is selected. (8) Connecting terminals (removable terminal block): The generously sized terminals permit connection of two conductors with different cross-sections for the auxiliary, control and sensor circuits. Connection is possible with screw connection and alternatively with spring-type connection. (9) 3RB29 85 function expansion module: Enables more functions to be added, e.g. internal ground fault detection and/or an analog output with corresponding signals. The LED indicates imminent tripping of the relay due to overload, phase unbalance or phase failure by flickering when the limit current has been violated. This warning can also issued as a signal through auxiliary contacts. In addition to the described inverse-time delayed protection of loads against excessive temperature rises, the 3RB22/3RB23 solid-state overload relays also allow direct temperature monitoring of the motor windings (full motor protection) by connection with short-circuit and open-circuit detection of a PTC sensor circuit. With this temperature-dependent protection, the loads can be protected against overheating caused indirectly by reduced coolant flow, for example, which cannot be detected by means of the current alone. In the event of overheating, the devices switch off the contactor, and thus the load, by means of the auxiliary contacts. The "tripped" status is signaled by means of a continuously illuminated "THERMISTOR" LED. To also protect the loads against high-resistance short-circuits due to damage to the insulation, humidity, condensed water, etc., the 3RB22/3RB23 solid-state overload relays offer the possibility of internal ground fault monitoring in conjunction with a function expansion module (for details see Selection and Ordering Data, not possible in conjunction with contactor assembly for Wye-Delta starting). In the event of a ground fault the 3RB22/ 3RB23 relays trip instantaneously. The "tripped" status is signaled by means of a continuous red "GND Fault" LED. Signaling through auxiliary contacts is also possible. After tripping due to overload, phase unbalance, phase failure, thermistor tripping or ground fault, the relay is reset manually or automatically after the recovery time has elapsed (see, LV 1 T Function). In conjunction with a function expansion module the motor current measured by the microprocessor can be output in the form of an analog signal 4 ... 20 mA DC for operating rotary coil instruments or for feeding into analog inputs of programmable logic controllers. With an additional AS-Interface analog module the current values can also be transferred over the AS-i bus system. The devices are manufactured in accordance with environmental guidelines and contain environmentally friendly and reusable materials. They comply with all important worldwide standards and approvals. 3RB29 06 current measuring module 5/44 Siemens LV 1 · 2007 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB22, 3RB23 for high-feature applications The most important features and benefits of the 3RB22/3RB23 solid-state overload relays are listed in the overview table (see Overload Relays, General Data). ■ Application Industries The 3RB22/3RB23 solid-state overload relays are suitable for customers from all industries who want to guarantee optimum inverse-time delayed and temperature-dependent protection of their electrical loads (e.g. motors) under normal and heavy starting conditions (CLASS 5 to CLASS 30), minimize project completion times, inventories and power consumption, and optimize plant availability and maintenance management. Application The 3RB22/3RB23 solid-state overload relays have been designed for the protection of three-phase asynchronous and single-phase AC motors. If single-phase AC motors are to be protected by the 3RB22/3RB23 solid-state overload relays, the main current paths of the current measuring modules must be seriesconnected (see LV 1 T, Schematics). Ambient conditions The devices are insensitive to external influences such as shocks, corrosive environments, ageing and temperature fluctuation. "Increased safety" type of protection EEx e according to ATEX directive 94/9/EC The 3RB22 (monostable) solid-state overload relays are suitable for the overload protection of explosion-proof motors with "increased safety" type of protection EEx e. The relays meet the requirements of EN 60079-7 (Electrical apparatus for potentially explosive atmospheres – Increased safety "e"). The basic safety and health requirements of ATEX directive 94/9/EC are fulfilled by compliance with • EN 60947-1 • EN 60947-4-1 • EN 60947-5-1 • EN 60079-14 EU type test certificate for Group II, Category (2) G/D exists. ■ Accessories The following accessories are available for the 3RB22/3RB23 solid-state overload relays: • A sealable cover for the evaluation module • Box terminal blocks for the current measuring modules size S6 and S10/S12 • Terminal covers for the current measuring modules size S6 and S10/S12 • Push-in lugs for screw mounting the size S00 to S3 current measuring modules For the temperature range from –25 C to +60 °C, the 3RB22/ 3RB23 solid-state overload relays compensate the temperature according to IEC 60947-4-1. Configuration notes for use of the devices below –25 °C or above +60 °C on request. Siemens LV 1 · 2007 5/45 5 ■ Benefits © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB22, 3RB23 for high-feature applications ■ Selection and ordering data Conversion aid 3RB12 ––> 3RB22/3RB23 Size Previous type Replacement type Overload relays (complete units) Current measuring module Evaluation module Function expansion module 3RB22/3RB23 3RB29 [email protected] 83-4AA1 3RB29 [email protected]@@ 3RB12 Setting range in A 3RB12 [email protected]@@ 1.25 ... 6.3 S00/S0 3RB12 [email protected]@@ 6.3 ... 25 S2/S3 3RB12 [email protected]@@ 25 ... 100 S6 3RB12 [email protected]@@ S10/S12 3RB12 [email protected]@@ 125 ... 500 3RB12 [email protected]@@ 5 50 ... 205 200 ... 820 3RB29 Setting range in A 3RB29 06-2BG11) 0.3 ... 3 3RB29 06-2DG11) 2.4 ... 25 3RB29 06-2JG11) 10 ... 100 3RB29 56-2TG22) 3RB29 56-2TH2 2) 3RB29 66-2WH22) 20 ... 200 63 ... 630 (820)3) 110 ... 120 V AC G Integrated Integrated 220 ... 240 V AC M Integrated Integrated 24 V DC B Integrated Integrated -- Standard version with ground fault signaling 00 Not available Standard version with overload warning 10 2 Version with internal ground fault detection and ground fault signal 20 2 CB1 Version with internal ground fault detection and overload warning 30 2 CA1 Version with analog output 40 2 AA0 Bistable version with ground fault signaling 01 Bistable version with overload warning 11 1) 2) 3) Use 3RB29 87-2B connecting cable. Use 3RB29 87-2D connecting cable. Motor currents up to 820 A can be recorded and evaluated by a current measuring module, e.g. 3RB29 06-2BG1 (0.3 ... 3 A) , in combination with a 3UF18 68-3GA00 (820 A / 1 A) series transformer. 5/46 Siemens LV 1 · 2007 Not available 3 Not required -Not required © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB22, 3RB23 for high-feature applications 3RB22/3RB23 solid-state overload relays for full motor protection with screw terminals or spring-loaded terminals for stand-alone installation, CLASS 5, 10, 20 and 30 adjustable Features and technical specifications: • Overload protection, phase failure protection and unbalance protection • External power supply 24 ... 240 V AC/DC • Auxiliary contacts 2 NO +2 NC • Manual and automatic RESET • Electrical remote RESET integrated • 4 LEDs for operating and status displays Size of contactor • TEST function and self-monitoring • Internal ground fault detection with function expansion module • Screw terminals or spring-loaded terminals for auxiliary, control and sensor circuits • Input for PTC sensor circuit • Analog output with function expansion module Version DT Screw terminals Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg Evaluation modules S00 ... S12 Monostable } 3RB22 83-4AA1 1 1 unit 101 0.300 Bistable } 3RB23 83-4AA1 1 1 unit 101 0.300 Version DT Spring-loaded terminals Size of contactor Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg Evaluation modules S00 ... S12 Monostable A 3RB22 83-4AC1 1 1 unit 101 0.300 Bistable A 3RB23 83-4AC1 1 1 unit 101 0.300 Version DT Order No. 3RB2. 83-4AC1 Size of contactor Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Function expansion modules for plugging into evaluation module (1 unit) S00 ... S12 1) Analog Basic 11) modules Analog output DC 4 ... 20 mA, with overload warning } 3RB29 85-2AA0 1 1 unit 101 0.030 Analog Basic 1 GF1)2) modules Analog output DC 4 ... 20 mA, with internal ground fault detection and overload warning } 3RB29 85-2AA1 1 1 unit 101 0.030 Analog Basic 2 GF1)2) modules Analog output DC 4 ... 20 mA, with internal ground fault detection and ground fault signaling } 3RB29 85-2AB1 1 1 unit 101 0.030 Basic 1 GF2) modules with internal ground fault detection and overload warning } 3RB29 85-2CA1 1 1 unit 101 0.030 Basic 2 GF2) modules with internal ground fault detection and ground fault signaling } 3RB29 85-2CB1 1 1 unit 101 0.030 The analog signal DC 4 ... 20 mA can be used for operating rotary coil instruments or for feeding into analog inputs of programmable logic controllers. 2) The following information on ground-fault protection refers to sinusoidal residual currents at 50/60 Hz: - With a motor current of between 0.3 and 2 times the set current Ie the unit will trip at a ground-fault current equal to 30 % of the set current. - With a motor current of between 2 and 8 times the set current Ie the unit will trip at a ground fault-current equal to 15 % of the set current. - The response delay amounts to between 0.5 and 1 second. * You can order this quantity or a multiple thereof. Siemens LV 1 · 2007 5/47 5 3RB2. 83-4AA1 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays 3RB22, 3RB23 for high-feature applications Current measuring modules for direct mounting1) and stand-alone installation1)2) Size of Rating for contactor3) induction motor Rated value4) kW Set current value of the inversetime delayed overload release Short-circuit DT Order No. protection with fuse, type of coordination 2, gL/gG operational class5) Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg A Size S00/S0 2)6) 0.09 … 1.1 0.3 … 3 20 } 3RB29 06-2BG1 1 1 unit 101 0.100 1.1 … 11 2.4 … 25 63 } 3RB29 06-2DG1 1 1 unit 101 0.150 S2/S3 5.5 … 45 10 … 100 315 } 3RB29 06-2JG1 1 1 unit 101 0.350 S6 with bar connection 11 … 90 20 … 200 315 } 3RB29 56-2TH2 1 1 unit 101 1.000 } 3RB29 56-2TG2 1 1 unit 101 0.600 } 3RB29 66-2WH2 1 1 unit 101 1.750 S00/S0 3RB29 06-2.G1 Size S2/S3 2)6) 3RB29 06-2JG1 5 Size S6 1)6) 3RB29 56-2TG2 S6 with box terminals Size S10/S121) S10/S12 37 … 450 and size 14 (3TF68/ 3TF69) 63 … 630 800 3RB29 66-2WH2 1) 2) 3) The current measuring modules with an Order No. ending with "2" are designed for direct mounting and stand-alone installation. For 3TF68/3TF69 contactors, direct mounting is not possible. The current measuring modules with an Order No. ending with "1" are designed for stand-alone installation. Observe maximum rated operational current of the devices. Size of contactor Version 4) 5) 6) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders. The modules with an Order No. with "G" in penultimate position are equipped with a straight-through transformer. DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Connecting cables For connection between evaluation module and current measuring module S00 ... S3 • Length 0.1 m (only for mounting of the evaluation module directly onto the current measuring module) } 3RB29 87-2B 1 1 unit 101 0.010 S00 ... S12 • Length 0.5 m } 3RB29 87-2D 1 1 unit 101 0.020 3RB29 87-2. * You can order this quantity or a multiple thereof. 5/48 Siemens LV 1 · 2007 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays Accessories ■ Overview Overload relays for standard applications Overload relays for high-feature applications The following accessories are available for the 3RB20/3RB21 solid-state overload relays: • One terminal bracket each for the overload relays size S00 and S0 (sizes S2 to S12 can be installed as single units without a terminal bracket) • One mechanical remote RESET module for all sizes • One cable release for resetting devices which are difficult to access (for all sizes) • One sealable cover for all sizes • Box terminal blocks for sizes S6 and S10/S12 • Terminal covers for sizes S2 to S10/S12 The following accessories are available for the 3RB22/3RB23 solid-state overload relays: • A sealable cover for the evaluation module • Box terminal blocks for the current measuring modules size S6 and S10/S12 • Terminal covers for the current measuring modules size S6 and S10/S12 • Push-in lugs for screw mounting the size S00 to S3 current measuring modules ■ Selection and ordering data Version Size DT Order No. Price PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Terminal brackets for stand-alone installation1) S00 } 3RB29 13-0AA1 1 1 unit 101 0.060 S0 } 3RB29 23-0AA1 1 1 unit 101 0.080 Resetting plungers, holders and formers S00 ... S10/S12 } 3RU19 00-1A 1 1 set 101 0.038 Pushbuttons with extended stroke (12 mm), IP65, Ø 22 mm B 3SB30 00-0EA11 1 1 unit 102 0.021 Extension plungers for compensation of the distance between a pushbutton and the unlatching button of the relay A 3SX1 335 1 1 unit 102 0.004 • Length 400 mm } 3RU19 00-1B 1 1 unit 101 0.063 • Length 600 mm } 3RU19 00-1C 1 1 unit 101 0.073 5 For separate mounting of the overload relays; screw and snap-on mounting onto TH 35 standard mounting rail 3RB29 .3-0AA1 Mechanical RESET2) 3RU19 00-1A with pushbutton and extension plunger Cable releases with holder for RESET2) For Ø 6.5 mm holes in the control panel; max. control panel thickness 8 mm S00 ... S10/S12 3RU19 00-1. 1) Only for 3RB20/3RB21. 2) Only for 3RB20/3RB21. The accessories are identical to those of the 3RU11 thermal overload relays. * You can order this quantity or a multiple thereof. Siemens LV 1 · 2007 5/49 © Siemens AG 2007 Overload Relays 3RB2 Solid-State Overload Relays Accessories Version Size DT Order No. Price PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Sealable covers For covering the setting knobs • For 3RB20/3RB21 S00 ... S10/S12 } 3RB29 84-0 1 10 units 101 0.020 • For 3RB22/3RB23 – } 3RB29 84-2 1 10 units 101 0.050 Terminal covers Covers for cable lugs and rail connections 5 3RT19 46-4EA1 3RT19 36-4EA2 The figures show mounting on the contactor • Length 55 mm1) S3 } 3RT19 46-4EA1 1 1 unit 101 0.037 • Length 100 mm S6 } 3RT19 56-4EA1 1 1 unit 101 0.067 • Length 120 mm S10/S12 } 3RT19 66-4EA1 1 1 unit 101 0.124 Covers for box terminals • Length 20.6 mm1) S2 } 3RT19 36-4EA2 1 1 unit 101 0.016 • Length 20.8 mm1) S3 } 3RT19 46-4EA2 1 1 unit 101 0.023 • Length 25 mm S6 } 3RT19 56-4EA2 1 1 unit 101 0.028 • Length 30 mm S10/S12 } 3RT19 66-4EA2 1 1 unit 101 0.038 Covers for screw terminals between contactor and overload relay, without box terminals (1 unit required per combination) S6 } 3RT19 56-4EA3 1 1 unit 101 0.021 S10/S12 } 3RT19 66-4EA3 1 1 unit 101 0.062 • Up to 70 mm2 S62) } 3RT19 55-4G 1 1 unit 101 0.237 • Up to 120 mm2 S6 } 3RT19 56-4G 1 1 unit 101 0.270 • Up to 240 mm2 S10/S12 } 3RT19 66-4G 1 1 unit 101 0.676 } 3RP19 03 1 10 units 101 0.002 100 10 units 101 0.100 Box terminal blocks For round and ribbon cables For conductor cross-sections, see LV 1 T "Technical Specifications" 3RT19 5.-4G Push-in lugs For screw fixing of 3RB22/3RB23 overload -relays 3RP19 03 For screw fixing of 3RB29 06 current measuring modules (2 units are required per module) S00 ... S3 C 3RB19 00-0B 3RB19 00-0B For more accessories (tools for spring-loaded terminals and labeling plates), see page 5/56. 1) 2) Only for 3RB20/3RB21. The accessories are identical to those of the 3RU11 thermal overload relays. In the scope of supply for 3RT10 54-1 contactors (55 kW). * You can order this quantity or a multiple thereof. 5/50 Siemens LV 1 · 2007
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement