ABB component drives Voltage and power range

ABB component drives Voltage and power range
ABB component drives
ACS55, 0.18 to 2.2 kW / 0.25 to 3 hp
PROFILE
INDUSTRIES
PRODUCTS
APPLICATIONS
EXPERTISE
PARTNERS
SERVICES
ABB component drives
ABB component drives meet the requirements of OEMs,
installation companies and panel builders. These drives
are components that are bought together with other
components from a logistical distributor. The drives are
stocked, and the number of options and, variants is
optimized for logistical distribution.
Highlights
■ Suitable for single phase residential and commercial
applications
■ Compact and slim
■ Flexible installation alternatives
■ Reduced motor noise with high switching frequency
■ Integrated 1st environment EMC filter as standard
■ Easy configuration via potentiometer and switches
■ Fast programming of powered and unpowered drives
with DriveConfig kit
ACS55_flyer_EN_revC_68899869.ind1 1
Voltage and power range
■ 1-phase, 110 to 120 V +10/-15%
0.18 to 0.37 kW (0.25 to 0.5 hp)
■ 1-phase, 200 to 240 V +10/-15%
0.18 to 2.2 kW (0.25 to 3 hp)
Applications
■
■
■
■
■
Fans
Pumps
Gate control
Material handling
Conveyors
Options
■ Input/Output chokes
■ Potentiometer
■ DriveConfig kit
8.4.2008 12:27:00
Ratings, types, voltages and dimensions
H
H2
W
D
= Height with mounting clip
= Height without mounting clip
= Width
= Depth
jog
reverse
ACS55
COM
COM
SPEED/AI
+10 V
+12 V
START
REV
JOG
SCR
start/
stop
10 RO1
11 RO2
Motor connection
Voltage
3-phase, from 0 to USUPPLY
(for 110/120 V from 0 to 230 V)
Frequency
0 to 120/130 Hz
Overload capacity
150% (60 s)
Control connections
One analog input
Voltage signal
0 (2) to 10 V, 200 kΩ single-ended
Current signal
0 (4) to 20 mA, 100 Ω single-ended
Potentiometer reference
value
10 V ±2% max. 10 mA, 1 kΩ ≤ R ≤ 10 kΩ
Response time
≤ 60 ms
Resolution
0.1%
Accuracy
±1%
Three digital inputs
12 V DC with internal or 12 to 24 V DC
external supply, PNP
Input impedance
1.5 Ω
Response time
≤ 9 ms
One relay output
Switching voltage
12 to 250 V AC or max 30 V DC
Maximum continuous
current
2A
Application parameters
fault or run
Supply terminals L, N (R, S)
Configuration switches
As standard
With DriveConfig kit
Motor nominal frequency
50/60 Hz
40 to 250 Hz
Acceleration time
0.1 to 30 s
0.1 to 100 s
Deceleration time
0.1 to 30 s
0.1 to 100 s
Maximum frequency
50 to 120 Hz
0 to 250 Hz
Relay output
Fault/Run
Fault/Fault (-1)/Run
Load type
Pump/fan or constant
Switching frequency
Standard
Control potentiometers
H1
DriveConfig kit interface
H2
Relay output terminals
Analogue input signal selector (U/I)
Control terminal
Motor terminals T1, T2, T3 (U, V, W)
Features available with
DriveConfig kit
W
Application macro selection, IR compensation,
constant speed selection, stop mode selection,
reset mode selection
Product compliance
CE, UL, cUL, C-Tick and GOST R approvals
Environmental limits
Degree of protection
D
5 kHz, adjustable up to 16 kHz with automatic
switching frequency reduction
Ambient temperature
-20 to 40 °C
IP20
with nominal current and 5 kHz switching
frequency, no frost allowed
up to 50 °C
with derating
Relative humidity
lower than 95% (without condensation)
For more information see technical catalogue
ABB component drives, ACS55 (3AFE68899842).
ABB Oy
Drives
P. O. Box 184
FI - 00381 Helsinki
Finland
Telephone +358 10 22 11
Fax
+358 10 22 23764
Internet
www.abb.com/drives
ACS55_flyer_EN_revC_68899869.ind2 2
© Copyright 2008 ABB. All rights reserved. 3AFE68899869 REV C EN 26.3.2008 Specifications subject to change without notice. Ad agency Piirtek Oy #13703
Ratings
Output current
Input
Type code
Frame
size
H1
H2
W
D
Weight
PN
PN nominal max current
kW
hp
A
A
A
mm mm mm mm
kg
Inbuilt EMC filter, 1-phase supply voltage 200/240 V, +10/-15%, 3-phase output 200/240 V
0.18 0.25
1.4
2.1
4.4
ACS55-01E-01A4-2
A
170 146.5 45
128
0.65
0.37
0.5
2.2
3.3
6.9
ACS55-01E-02A2-2
A
170 146.5 45
128
0.7
0.75
1.0
4.3
6.5
10.8 ACS55-01E-04A3-2
B
170 146.5 67.5 128
0.7
1.5
2
7.6
11.4
18.2 ACS55-01E-07A6-2
D
226 203
70
159
1.1
2.2
3
9.8
14.7
22
ACS55-01E-09A8-2
D
226 203
70
159
1.1
No EMC filter, 1-phase supply voltage 200/240 V, +10/-15%, 3-phase output 200/240 V
0.18 0.25
1.4
2.1
4.4
ACS55-01N-01A4-2
A
170 146.5 45
128
0.65
0.37
0.5
2.2
3.3
6.9
ACS55-01N-02A2-2
A
170 146.5 45
128
0.7
0.75
1.0
4.3
6.5
10.8 ACS55-01N-04A3-2
B
170 146.5 67.5 128
0.7
1.5
2
7.6
11.4
18.2 ACS55-01N-07A6-2
C
194 171
70
159
1.1
2.2
3
9.8
14.7
22
ACS55-01N-09A8-2
C
194 171
70
159
1.1
Inbuilt EMC filter, 1-phase supply voltage 110/120 V, +10/-15%, 3-phase output 200/240 V
0.18 0.25
1.4
2.1
6.4
ACS55-01E-01A4-1
A
170 146.5 45
128
0.65
0.37
0.5
2.2
3.3
9.5
ACS55-01E-02A2-1
A
170 146.5 45
128
0.7
No EMC filter, 1-phase supply voltage 110/120 V, +10/-15%, 3-phase output 200/240 V
0.18 0.25
1.4
2.1
6.4
ACS55-01N-01A4-1
A
170 146.5 45
128
0.55
0.37
0.5
2.2
3.3
9.5
ACS55-01N-02A2-1
A
170 146.5 45
128
0.6
Find your nearest contact at
www.abb.com/drivespartners
8.4.2008 12:27:02
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement