ABB component drives ACS55, 0.18 to 2.2 kW / 0.25 to 3 hp PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS SERVICES ABB component drives ABB component drives meet the requirements of OEMs, installation companies and panel builders. These drives are components that are bought together with other components from a logistical distributor. The drives are stocked, and the number of options and, variants is optimized for logistical distribution. Highlights ■ Suitable for single phase residential and commercial applications ■ Compact and slim ■ Flexible installation alternatives ■ Reduced motor noise with high switching frequency ■ Integrated 1st environment EMC filter as standard ■ Easy configuration via potentiometer and switches ■ Fast programming of powered and unpowered drives with DriveConfig kit ACS55_flyer_EN_revC_68899869.ind1 1 Voltage and power range ■ 1-phase, 110 to 120 V +10/-15% 0.18 to 0.37 kW (0.25 to 0.5 hp) ■ 1-phase, 200 to 240 V +10/-15% 0.18 to 2.2 kW (0.25 to 3 hp) Applications ■ ■ ■ ■ ■ Fans Pumps Gate control Material handling Conveyors Options ■ Input/Output chokes ■ Potentiometer ■ DriveConfig kit 8.4.2008 12:27:00 Ratings, types, voltages and dimensions H H2 W D = Height with mounting clip = Height without mounting clip = Width = Depth jog reverse ACS55 COM COM SPEED/AI +10 V +12 V START REV JOG SCR start/ stop 10 RO1 11 RO2 Motor connection Voltage 3-phase, from 0 to USUPPLY (for 110/120 V from 0 to 230 V) Frequency 0 to 120/130 Hz Overload capacity 150% (60 s) Control connections One analog input Voltage signal 0 (2) to 10 V, 200 kΩ single-ended Current signal 0 (4) to 20 mA, 100 Ω single-ended Potentiometer reference value 10 V ±2% max. 10 mA, 1 kΩ ≤ R ≤ 10 kΩ Response time ≤ 60 ms Resolution 0.1% Accuracy ±1% Three digital inputs 12 V DC with internal or 12 to 24 V DC external supply, PNP Input impedance 1.5 Ω Response time ≤ 9 ms One relay output Switching voltage 12 to 250 V AC or max 30 V DC Maximum continuous current 2A Application parameters fault or run Supply terminals L, N (R, S) Configuration switches As standard With DriveConfig kit Motor nominal frequency 50/60 Hz 40 to 250 Hz Acceleration time 0.1 to 30 s 0.1 to 100 s Deceleration time 0.1 to 30 s 0.1 to 100 s Maximum frequency 50 to 120 Hz 0 to 250 Hz Relay output Fault/Run Fault/Fault (-1)/Run Load type Pump/fan or constant Switching frequency Standard Control potentiometers H1 DriveConfig kit interface H2 Relay output terminals Analogue input signal selector (U/I) Control terminal Motor terminals T1, T2, T3 (U, V, W) Features available with DriveConfig kit W Application macro selection, IR compensation, constant speed selection, stop mode selection, reset mode selection Product compliance CE, UL, cUL, C-Tick and GOST R approvals Environmental limits Degree of protection D 5 kHz, adjustable up to 16 kHz with automatic switching frequency reduction Ambient temperature -20 to 40 °C IP20 with nominal current and 5 kHz switching frequency, no frost allowed up to 50 °C with derating Relative humidity lower than 95% (without condensation) For more information see technical catalogue ABB component drives, ACS55 (3AFE68899842). ABB Oy Drives P. O. Box 184 FI - 00381 Helsinki Finland Telephone +358 10 22 11 Fax +358 10 22 23764 Internet www.abb.com/drives ACS55_flyer_EN_revC_68899869.ind2 2 © Copyright 2008 ABB. All rights reserved. 3AFE68899869 REV C EN 26.3.2008 Specifications subject to change without notice. Ad agency Piirtek Oy #13703 Ratings Output current Input Type code Frame size H1 H2 W D Weight PN PN nominal max current kW hp A A A mm mm mm mm kg Inbuilt EMC filter, 1-phase supply voltage 200/240 V, +10/-15%, 3-phase output 200/240 V 0.18 0.25 1.4 2.1 4.4 ACS55-01E-01A4-2 A 170 146.5 45 128 0.65 0.37 0.5 2.2 3.3 6.9 ACS55-01E-02A2-2 A 170 146.5 45 128 0.7 0.75 1.0 4.3 6.5 10.8 ACS55-01E-04A3-2 B 170 146.5 67.5 128 0.7 1.5 2 7.6 11.4 18.2 ACS55-01E-07A6-2 D 226 203 70 159 1.1 2.2 3 9.8 14.7 22 ACS55-01E-09A8-2 D 226 203 70 159 1.1 No EMC filter, 1-phase supply voltage 200/240 V, +10/-15%, 3-phase output 200/240 V 0.18 0.25 1.4 2.1 4.4 ACS55-01N-01A4-2 A 170 146.5 45 128 0.65 0.37 0.5 2.2 3.3 6.9 ACS55-01N-02A2-2 A 170 146.5 45 128 0.7 0.75 1.0 4.3 6.5 10.8 ACS55-01N-04A3-2 B 170 146.5 67.5 128 0.7 1.5 2 7.6 11.4 18.2 ACS55-01N-07A6-2 C 194 171 70 159 1.1 2.2 3 9.8 14.7 22 ACS55-01N-09A8-2 C 194 171 70 159 1.1 Inbuilt EMC filter, 1-phase supply voltage 110/120 V, +10/-15%, 3-phase output 200/240 V 0.18 0.25 1.4 2.1 6.4 ACS55-01E-01A4-1 A 170 146.5 45 128 0.65 0.37 0.5 2.2 3.3 9.5 ACS55-01E-02A2-1 A 170 146.5 45 128 0.7 No EMC filter, 1-phase supply voltage 110/120 V, +10/-15%, 3-phase output 200/240 V 0.18 0.25 1.4 2.1 6.4 ACS55-01N-01A4-1 A 170 146.5 45 128 0.55 0.37 0.5 2.2 3.3 9.5 ACS55-01N-02A2-1 A 170 146.5 45 128 0.6 Find your nearest contact at www.abb.com/drivespartners 8.4.2008 12:27:02
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement