ASSEMBLY 1. Take OFF the power.

ASSEMBLY 1. Take OFF  the power.
ASSEMBLY
1. Take OFF the power.
2. Put on the relay on the rail in switchgear box.
3. Connect the relay to circuitry with wiring diagram.
4. By flat screwdriver set to switching threshold .
F&F Filipowski sp. j
ul. Konstantynowska 79/81
95-200 Pabianice POLAND
tel/fax 48 42 2270971
e-mail: [email protected]
AS-212
AR
RAN
24
TY
W
STAIRCASE TIMERS
AR
TY
W
MONTHS
RAN
5
9 0 8 3 1 2
5 9 2 0 6 8
>
www.fif.com.pl
F&F products are covered by an 24 months warranty from date of purchase
PURPOSE
Staircase timer AS-212 serves to keep switched-ON lighting
of staircase, corridor, or any other object for the set time and
to switch-OFF this lighting automatically, upon elapse of this
set time.
TECHNICAL DATA
supply
230V AC
curent load
<16A
switching OFF delay (to set)
0,5÷10min
switching ON delay
<1sec
connection
screw terminals 2,5mm²
power consumption
0,56W
working temperature
-25÷50°C
dimensions
1 module (18mm)
fixing
on the rail TH-35
WIRING DIAGRAM
L
N
1
FUNCTIONING
Turned ON staircase timer supports the lighting during set
time by potentiometer (from 0,5min. to 10min.). After
passage of set time timer will switch OFF the lighting
automatically. After switching OFF the lighting there is
possibility to switch it ON again.
3
12
3 wires connection
L
N
3
1
ATTENTION!
10
12
AS-212 is
adapted to co-operate with pushbuttons
equipped with neon lamp.