THURLBY THANDAR INSTRUMENTS 1604 4¾ digit Bench Multimeter TTi 1604 All accuracies apply for 1 year, 19oC to 25oC. Temperature coefficient outside these limits is <0.1 x quoted range accuracy per oC. 40,000 COUNT DIGITAL MULTIMETER T-Hold V Hold T-Hld Ω k ΩΩ A Min Null kΩ Max Hz Auto mV mA Continuity Diode Test mV Ω V Hold Min-Max mA Null Reset DC AC Hz (AC Ranges) Operate THURLBY THANDAR INSTRUMENTS All inputs 1kV Cat.I, 600V Cat.IImax. to 10A mA 10A max. FUSED 1A max. FUSED Range Accuracy Resolution Notes 400mV 4V 40V 400V 1000V 0.08% ± 4 dig. 0.08% ± 4 dig. 0.08% ± 4 dig. 0.08% ± 4 dig. 0.09% 4 dig. 10µV 100µV 1mV 10mV 100mV Max. Input 265V DC/AC rms Input impedance 10MΩ nominal Max. input 1kV DC or AC pkNMR: >60dB @ 50/60Hz CMR: >90dB @ DC/50Hz/60Hz Auto/Man SHIFT FUNCTION HIGH RESOLUTION MEASUREMENT SERIAL DATA INTERFACE TRUE RMS AC AC Power DC VOLTAGE Review A RANGE V/ ΩΩ COM max. 750V AC 1000V DC AC VOLTAGE (True RMS, 4000 count scale length) 40,000 count scale length ● Accuracy 0.08%; resolution 10µV, 10mΩ & 0.1µA ● Large and bright LED display; ac line operation ● True RMS ac functions; wide ac bandwidth ● Frequency measurement; continuity; diode test ● Relative, T-Hold and Min-Max functions included ● Isolated RS-232 interface as standard ● A value-for-money DMM The 1604 is a low-cost auto/manual ranging bench-top DMM with a large and bright LED display. It offers 4¾ digit (40,000 count) scale length, true RMS ac measurements, a basic accuracy of 0.08% and a resolution of 10µV, 10mΩ and 0.1µA. A substantial bench-top instrument The 1604 is a robust mains-powered bench-top instrument. Unlike a hand-held multimeter it stays where you put it even with heavy test leads connected. The multi-position tilt stand ensures that the large display is always readable. Smart functions The 1604 incorporates several “smart” functions such as Relative measurement and Minimum-Maximum storage. The T-Hold function enables readings to be held on the display automatically each time a new test point is probed. True RMS ac ranges All AC measurements on the 1604 are True RMS. This avoids the errors on non-sinusoidal waveforms associated with other multimeters. Good ac bandwidth enables measurement within the audio band and ensures that higher frequency components of switching waveforms are included within the measurement result. Frequency measurement The 1604 has a frequency function which can be selected on any ac range in order to measure the frequency of the signal. Frequencies up to 40kHz can be measured and the maximum resolution is 0.1Hz. Isolated RS-232 interface The 1604 is fitted with an isolated RS-232 interface. This permits remote control and data-logging to disk using optional Windows based software. DISPLAY and RANGE CONTROL 0.56” (14mm) LED display. Annunciators for all ranges, functions and 'smart' modes. Scale Length 4¾ digits (± 40,000 counts) except ac ranges ( 4,000 counts). Reading rate 2.5 per second. Each measurement function can use automatic or up/down manual ranging. RS-232 INTERFACE Opto-isolated bi-directional RS-232 interface. 9600 baud. GENERAL Power: Size: Weight: Operating Range: Storage Range: Safety: EMC: 230V or 115V AC nominal 50/60Hz, adjustable internally; operating range ±14% of nominal; 3VA max.; Installation category II 260(W) x 88(H) x 235(D)mm, excl. handle/feet. 2.0kg (4.4lb) + 5°C to 40°C, 20-80% RH. - 40°C to 70°C Complies with EN61010-1. Complies with EN55081-1 and EN50082-1. Note: This is a faxable data sheet, a colour brochure is also available. Range Accuracy Resolution 400mV 4V 40V 400V 750V 45Hz - 400Hz 400Hz - 5kHz 5kHz - 20kHz 1% ± 4 dig. 3% ± 4 dig. 0.5% ± 4 dig. 2% ± 4 dig. 5% ± 4 dig. 3% ± 4 dig. 1% ± 4 dig. 100µV 1mV 10mV 100mV 1V Accuracies apply for readings between 10% and 100% of full scale. Additional error at crest factor = 3 is typically 1%. Input impedance = 10MΩ nominal. Max. input = 750V rms, 1kV pk. (265V rms on 400mV range). 1kΩ unbalanced CMR = >60dB at DC or 50Hz (60Hz rejection available as factory option). RESISTANCE Range Accuracy Resolution Notes 400Ω 4kΩ 40kΩ 400kΩ 4MΩ 40MΩ 0.15% ± 6 dig.* 0.1% ± 4 dig. 0.1% ± 4 dig. 0.15% ± 4 dig. 0.3% ± 6 dig. 1.0% ± 10 dig. 10mΩ 100mΩ 1Ω 10Ω 100Ω 1kΩ * 400Ω specification applies after null Max. input 265V DC or AC rms on any range. Max. open circuit voltage 4V 40MΩ accuracy applies up to 20MΩthereafter add 1% DC CURRENT Range Accuracy Resolution Notes 4mA 400mA 10A (up to 1A) 10A (up to 5A) 10A (up to 10A) 0.1% ± 4 dig. 0.1% ± 4 dig. 0.3% ± 4 dig. 1.0% ± 4 dig. 3.0% ± 10 dig. 0.1µA 10µA 1mA 1mA 1mA Max. input 1A (Fused) Voltage burden <500mV Max. input 10A (Fused) Voltage burden <500mV AC CURRENT (True RMS, 4000 count scale length) Range Accuracy Resolution Notes 1mA 100mA 10A (up to 1A) 10A (up to 5A) 10A (up to 10A) 0.5% ± 4 dig. 0.5% ± 4 dig. 0.8% ± 4 dig. 1.5% ± 4 dig. 3.0% ± 4 dig. 1µA 100µA 10mA 10mA 10mA Max. input 1A (Fused) Voltage burden <500mV Max. input 10A (Fused) Voltage burden <500mV Accuracies apply over 45Hz to 10kHz for readings between 10% and 100% of range. Additional error at crest factor = 3 is typically 1%. FURTHER FUNCTIONS Continuity Selects 4kΩ range and sounds audible tone for impedance <10Ω. Max. input 265V DC or AC rms. Diode Test Displays junction voltages up to 3V at a test current of 1mA at 1V. Max. open circuit voltage approximately 4V. Max. input 265V DC or AC rms. Null (Relative): Hold: T-Hold: Min/Max: Stores current reading and subtracts it from future readings. Reading is frozen until released. Reading is frozen when it becomes stable. Minimum and maximum readings are stored. Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. Designed and built in the EEC by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon. Cambs. PE18 7DX England Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409 e-mail: [email protected] Web: http://www.ttinst.co.uk
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement