TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. CAL Controls shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
ENVIRONMENTAL CONDITIONS
Ambient/storage temperature 0 ... +50°C/-25 ... +70°C (with no icing)
80% up to 31°C decreasing linearly 50% at 40°C.
Max. Relative humidity
Rated pollution degree
According to EN 60529
Front panel : IP60
Rear panel : Ip20
Height
Max. 2000m
CAL ETM1411 DIGITAL TIMER
Do not use the device in locations subject to corrosive and flammable gases.
Thank you for choosing the CAL ETM1411 digital timer.
* 34 x 77mm sized.
* Single contact output for timing control.
ETM1411
* External start input.
OUT
* Display can be adjusted to show min. or sec.
* Scale ;
0:01 .... 99:59 min.
0:01 .... 99:59 hour
* Decrease and increace step of time can be adjusted.
CAL
* Start and stop possibility by front panel.
* 16 different warning tones.
* Upper and lower limits of the setpoint can be adjusted.
* CE marked according to European Norms.
Output
Supply Voltage
230V AC +%10 -%20
12V AC/DC ±%10
24V AC/DC ±%10
Relay
ELECTRICAL CHARACTERISTICS
START
HOUR MIN
SET
DIGITAL TIMER
230V AC +%10 -%20, 50/60Hz or 24V AC/DC ±%10, 50/60Hz or 12V AC/DC ±%10, 50/60Hz.
Max 3VA
2.5mm² screw-terminal connections
Selectable 99:59 min. or hour.
1 sec.
±%1
4 digits, 12mm, 7 parts yellow LED
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 (pollution degree 2, overvoltage category II)
Supply
Power consumption
Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC
STOP
Safety requirements
OUTPUT
OUT
Life expectancy for relay
Order Code
ETM1411-230VAC
ETM1411-12
ETM1411-24
Relay: 250V AC, 8A (for resistive load), NO+NC
Mechanical 30.000.000 operation; Electrical 100.000 operation
START INPUT
Control with mechanical contact.
Input type
On and Off times for input pulses Min. = 100ms, Max. =
4
Connection Diagram
HOUSING
Housing type
Dimensions
Weight
Enclosure material
CAL ETM1411 is intended for installation in control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side.
During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input and
output lines that are not connected to the supply network must be laid out as shielded and
twisted cables. These cables should not be close to the power cables or components. The
installation and electrical connections must be carried out by qualified staff and must be
according to the relevant locally applicable regulations.
Suitable for panel mounting
W77xH34xD70mm
Approx. 240g (after packing)
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Dimensions
Depth
85mm
70mm
For removing mounting clamps:
www.cal-controls.com
ETM1411
OUT
Equipment is protected throughout
by DOUBLE INSULATION.
12V AC/DC ±10%
50/60Hz 3VA
OUT
250V AC 8A
RESISTIVE LOAD
9 10 11 12
START
6
7
8
9 10 11 12
1
2
3
4
5
6
7
8
8
5
7
4
6
3
5
START
9 10 11 12
SN: XXXXXXXXX
Line
Note:
Switch
230V AC
Supply
Neutral
Fuse should
be connected.
Cable size: 1,5mm²
Panel cut-out
71mm
www.cal-controls.com
184-253V AC 7
50/60Hz 3VA 8
Fuse
F 100 mA
250V AC
ETM1411-230VAC
DIGITAL TIMER
NOTE :
SUPPLY:
mounting
clamp
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.
1/2
Panel Rubber
gasket
1
OUT
250V AC 8A
RESISTIVE LOAD
2
4
230V AC +10% -20%
50/60Hz 3VA
2
mounting
clamp
230V AC +10% -20%
50/60Hz 3VA
1
STOP
3
OUT
250V AC 8A
RESISTIVE LOAD
DIGITAL TIMER
Holding screw
0.4-0.5Nm
2
START
SET
CAL
8mm
Push out the mounting clamp
in direction 1 as shown
in the figure below. Then, pull
out the clamp in direction 2.
MIN
29mm
SN: XXXXXXXXX
SN: XXXXXXXXX
HOUR
34mm
ETM1411-12
DIGITAL TIMER
ETM1411-230VAC
DIGITAL TIMER
START
1
www.cal-controls.com
CAL CONTROLS LTD
Bury Mead Road, Hitchin, Herts, SG5 1RT, UK.
Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801
e-mail: [email protected] Web : www.cal-controls.com
Note: 1) Panel thickness
should be maximum
7 mm.
2) If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the panel.
ETM1411-E-03
INDICATOR OF
SELECTING
HOUR
INDICATOR OF
CONTACT OUTPUT
INDICATOR OF
SELECTING
MINUTE
ETM1411
OUT
Displayed time value in the run mode, parameter value or name in the programming mode.
When held down for one second in the run mode, timer runs. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the
run mode. When held down for a few seconds, the change rate accelerates.
START
HOUR
MIN
SET
CAL
When held down for one second in the run mode, timer and voiced warning are stopped.(When Str.t. = TYP.1 mode is selected, timer and voiced warning can be stopped if external start input is off). Used
for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.
DIGITAL TIMER
STOP
SET
Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. For adjusting the selected parameter, while holding
adjusted by using
and
keys.
CONTROL DIAGRAM BY EXTERNAL START INPUT
Run Mode
:59
30
1000
Time
value
60:00
SET
key, the value can be
Out.t.
59:59
60:00
TYP.0
TYP.1
SET
Str.t.
Power
SET
When pressed
key, TIMER set value flashes and by using
with the step defined byIn.de.
and
keys the value can be adjusted
Out
TYP.0
SET
Start
input
Stop
key
SET
If
key is pressed and held for 3 seconds,
programming mode is entered.
If
key is pressed,
run mode is entered.
Indicator
Programming Mode
T.S.
T.lol
T.uPl
In.de
T.c.
The lower limit
of the setpoint.
Adjustable between
0.01 and T.uPl.
T.bas
The upper limit
of the setpoint.
Adjustable between
T.lol and 99.59.
Str.t.
Increase or decrease
step of the setpoint.
Adjustable between
1 and 30.
Out.t.
Sond.
Power
SE
Selection of time unit.
If min is selected, time can be
adjutable max. 99:59 min.
If Hour is selected, time can be
adjutable max. 99:59 h.
Selection of start type.
By external start input and
start/stop keys, timer can be run
and stopped. 4 different selection
types are defined in the
control diagram.
Selection of relay output.
If typ.0 is selected, timer runs
by start and relay contact shuts.
When time is over, relay contact
opens. If typ.1 is selected, timer
runs by start. When time is over,
relay contact shuts.
Selection of buzzer voice type.
Adjustable 16 different voice types.
If this parameter is selected 0,
voiced warning is canceled.
S.Cod.
TYP.1
Access code for entering
security menu.
This parameter should be 411.
Out
Start
input
Indicator
CONTROL DIAGRAM BY START & STOP KEYS
A.-t.S.
A.-T.c.
Access code for timer set menu
NonE= Menu is invisible.
P.yes= Parameters of menu
are changeable.
P.no= Parameters of menu
are only visible.
Access code for
timer configuration menu.
NonE= Menu is invisible.
P.yes= Parameters of menu
are changeable.
P.no= Parameters of menu
are only visible.
Out.t.
Str.t.
TYP.0
TYP.1
Power
Out
TYP.2
Start
key
Stop
key
Indicator
Power
Out
TYP.3
Start
key
Stop
key
Indicator
2/2
ETM1411-E-03
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF