OWNER’S MANUAL
FOR HOUSEHOLD USE ONLY
Please read this document carefully before installing and/or using your central vacuum cleaning system.
MODEL : _______________ SERIAL NO : ______________________
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following.
Read all instructions before using this appliance
WARNING
– To reduce the risk of fi re, electric shock, or injury:
1. Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not allow to be used as a toy. Close attention is necessary when used by or near children or infi rm persons. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
4. Use only as described in this manual. Use only manufacturer’s recommended attachments.
5. Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord.
Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
8. Do not handle plug or appliance with wet hands.
9. Do not put any objects into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air fl ow.
10. Keep hair, loose clothing, fi ngers, and all parts of body away from openings and moving parts.
11. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
12. Do not use without dust bag and/or fi lters in place.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up fl ammable or combustible liquids such as gasoline or use in areas where they may be present.
16. Connect to a properly grounded outlet only. See Grounding Instructions.
SAVE THESE INSTRUCTIONS
3
Table of Contents
INSTALLATION
8
9
Installing the Remote Monitor 16
OPERATING INSTRUCTIONS
Progressive Start and Delayed Stop 19
Maintenance Suggestions Module 20
MAINTENANCE
TROUBLESHOOTING
Decrease in suction strength 28
WARRANTY INFORMATION
One Year Satisfaction Guarantee 32
Warranty on Cyclo Vac Attachments 33
6
6
7
5
6
Preface
Your new Cyclo Vac central vacuum system was designed and manufactured in
Blainville, Quebec, by the largest central vacuum cleaner manufacturer in Canada.
With over forty years of experience in the fi eld, we provide a high-quality, state-ofthe-art product, and guarantee your complete satisfaction. Our extensive network of qualifi ed professionals ensures fi rst quality service near you. Contact us for the location of the Cyclo Vac authorized service center in your area.
Schematic – E100
1. Circuit Breaker
2. Low Voltage Connector
3. Serial Number
4. Air Intake
5. Air Exhaust
4 min. 30 cm (12")
Recommende 40 cm (16") min. 30 cm (12")
5 min. 30 cm (12") min. 5 cm (2")
1
2
3
With muffl er turned down, min. 30 cm (12")
90 cm (36")
Schematic – Other Models
1. Circuit Breaker
2. Reset (DL series only)
3. LEDs (DL series only)
4. Low Voltage Connector
5. Serial Number
6. Air Intake
7. Air Exhaust min. 30 cm (12")
With muffl er turned down, min. 30 cm (12")
1
2
3
4
5
6
7 min. 30 cm (12") min. 30 cm (12") min. 30 cm (12")
Recommende 40 cm (16")
95 cm (38")
7
Unit Installation
Using the mounting plate provided with your vacuum cleaner, secure the unit to the wall (fi gure 1), at a height allowing easy access for maintenance of the fi lters, dirt receptacle and/or bags (see pages 6 and 7).
fi gure 1
The connections to the piping system will require some basic tools: a mitre box and small saw or a pipe cutter (fi gure 2). See pages 9 and 10 for general instructions pertaining to the preparation of PVC pipes. To simplify matters, installation kits, including necessary fi ttings, pipes, glue and wiring, as well as a detailed instructions booklet, are available from
Cyclo Vac service centers.
fi gure 2
8
Contrary to all other connections in the piping system, do not glue the last fi tting
to your unit. Cyclo Vac central vacuums are equipped with an adjustable air intake valve (fi gure 3), which does not require glue. An air-tight fi t is achieved with the screw-type adjustment on the fi tting itself.
Installation fi gure 3
INSTALLING CONDUITS
Dos & Don’ts
Installation 9
Dos & Don’ts
10 Installation
Dos & Don’ts
INSTALLING INLETS
When installing your vacuum inlets, we recommend that the principle of electric polarity be taken into account. Ensure that the wire connected onto contact A on inlet 1 is the same as that connected to contact A on inlet 2, and so on. Do not cross, reverse or interchange wires.
A
B inlet 1
A
B inlet 2
Installation 11
12
Muffler Installation
1. Insert the rubber coupling (A) on the air exhaust (D).
2. Using a Phillips (star shape) screwdriver, tighten the clamp collar on the rubber coupling to ensure adequate sealing.
3. Insert the 90° elbow (B) into the rubber coupling, and tighten the clamp collar.
4. Insert the muffl er (C) on the end of the 90° elbow.
E100 MODEL
C
A. Rubber coupling
B. 90° elbow
C. Muffl er
D. Air Exhaust
B
A
D
OTHER MODELS
A
C
A
D
B
Installation
Electric Connections
There should be an electric outlet within 1 meter (3 feet) of your central vacuum unit. Once the appliance is installed in a suitable location, connect your central unit to an electric outlet on an dedicated* grounded circuit. Do not use extension cords or modify the length of your vacuum cleaner’s power cord.
DEDICATED* GROUNDED CIRCUIT
• North America
120 V / 240 V All models: 15 A
• European continent and other
220 V / 240 V Model DL200SV: 10 A
220 V /240 V All other models: 8 A
Your central vacuum cleaner has a thermal safety device or a circuit breaker to protect against any over voltage or electrical defect. If that protection should fail, contact your authorized service center.
*Please reserve a circuit breaker dedicated only to the connections for your central vacuum.
If you fi nd that installing your vacuum cleaner is too diffi cult, ask your service center to install it for you. When in doubt, it is better to have the work done by a professional and ensure that the unit is properly installed. Any installation that does not comply with the specifi ed norms could alter or invalidate the warranty.
Installation 13
Grounding Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipmentgrounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. No adaptor should be used with this appliance.
WARNING
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualifi ed electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance – if it will not fi t the outlet; have a proper outlet installed by a qualifi ed electrician.
120 V MODELS
This appliance is for use on a nominal 120 V circuit, and has a grounded plug (fi gure 4). Make sure that the appliance is connected to an outlet having the same confi guration as the plug. No adaptor should be used with this appliance.
fi gure 4
220 V/240 V MODELS
This appliance is for use on a circuit having a nominal rating more than 120 V and is factory-equipped with a specifi c cord and plug to permit connection to a proper electric circuit. Make sure that the appliance is connected to an outlet having the same confi guration as the plug. No adaptor should be used with this appliance. If the appliance must be reconnected for use on a different type of electric circuit, the reconnections should be made by a qualifi ed service personnel.
14
Type C Type G Type H
Installation
Type I Nema 6-15 R
Low Voltage Connections
Connect the low voltage wires to the low voltage inlet on your unit. To do so, simply terminals from the low voltage inlet on the unit, and proceed according to the types of inlet and wire used.
STANDARD LOW VOLTAGE INLET
All types of wire:
Twist the stranded wire to tighten the loose strands together before proceeding. Insert the wire into the terminal (blue connector).
Using your wire strippers, tighten the terminal at two places: at the front, to hold the wire in place, and at the back to tighten the insulator around the wire (fi gure 5). If the insulator does not completely cover the stripped wire, use electrical tape to insulate the wire adquately, and prevent all contact between the 2 wires. Insert the terminal into the low voltage inlet (fi gure 6).
To disconnect:
Do not pull on wire. Simply remove the terminal from the low voltage inlet.
fi gure 5 fi gure 6
Installation 15
16
Installing the Remote Monitor
(Optional — DL300 only)
Having determined the location of both the central vacuum unit and the Remote System Monitor, run low voltage wiring to connect the Monitor to the central vacuum power unit.
Installing the Remote Monitor
1. Insert the low voltage wire into the mounting box through one of the designated openings, and fasten within the wall at the determined location (fi gure 11).
2. Having stripped the exterior casing of the four-stranded wire, strip 0,5 cm (¼") of each color wire.
3. Connect wires to the module connector. Insert each of the 4 color wires in the corresponding color-coded inlet on the connector.
To do so, loosen the screw on the side of each inlet, insert the wire, and tighten screw to ensure a tight connection. Repeat for each of the remaining 3 wires (fi gure 12).
4. Insert the connector to the electronic module and ensure it holds in place (fi gure 13).
5. Screw the electronic module to the mounting box, with the two screws provided (fi gure 14).
6. Complete with the “Decora” fi nishing plate.
fi gure 11 fi gure 12 fi gure 13
A. Red
B. Black
C. Green
D. Yellow fi gure 14
Installation
Installing the Remote Monitor
(Optional — DL300 only)
Connections on the Vacuum Power Unit
1. Having stripped the exterior casing of the four-stranded wire, strip 0,5 cm (¼") of each color wire.
2. Connect wires to the power unit connector. Insert each wire in the designated inlet, of the corresponding color. To do so, simply open the connector, insert the wire, and close (fi gure 15). Repeat for the remaining 3 wires.
fi gure 15
A. Red
B. Black
C. Green
D. Yellow
Installation 17
Hose Hook-up & Inlets
Before operating your central vacuum…
Please verify that it is properly connected to the piping system, and to a grounded electrical outlet, and that the low voltage wires are connected to the unit (see pages 8 to 16). Then read the complete owner’s manual and proceed with a quick verifi cation of your unit’s installation:
• Check fi lters to be sure they are properly installed.
• Check rubber seals in each vacuum inlet.
• Plug the hose alternatively into each vacuum inlet, to ensure that each one works properly.
• While the hose is still plugged into one inlet and the system is operational, check other inlets for leaks.
To start your central vacuum, simply insert the hose in the vacuum inlet of your choice. Please ensure that the tab on the hose end is properly lined up with the slot in the inlet opening (fi gure 16). If your hose handle has an integrated on/off switch, simply slide the switch to the “on” position.
Do not try to open another inlet while your system is in operation, as it may damage the inlet’s rubber seal.
18 fi gure 16
Operating Instructions
Speed Variation Hose
(DL Series Only)
Exclusive to Cyclo Vac, the Speed Variation hose allows the selection of 4 power levels by the simple slide of a switch on the hose handle. The light emitting diodes on the “Speed Variation” hose indicate the power level chosen. Flashing diodes inform you that the time has come to empty the receptacle or clean the fi lters. Refer to the maintenance suggestions module or the integrated system monitor on the unit itself (see pages 23 and 24).
WARNING
The use of an “SV” hose with a vacuum unit
other than that of the Cyclo Vac DL “SV” series will cause irreversible damage to your hose which would not be covered by the warranty.
Progressive Start and Delayed Stop
(DL Series Only)
Each DL model is equipped with a special module allowing for a smooth and gradual start-up of the vacuum system, to prolong motor durability. It will also come to a complete stop within a few seconds after it has been turned off, to allow for the complete evacuation of dust from the hose.
Operating Instructions 19
20
Maintenance Suggestions Module
(DL Series Only)
Cyclo Alert
Your unit is equipped with an electronic timing board that will suggest, by the color of the blinking LED, the type of maintenance that should be done. These signals are only suggestions and do not indicate a problem with your unit.
Your central vacuum will work normally despite the fl ashing LEDs. When you initially connect your unit, the LEDs will be green and steady. When the LEDs on the hose handle blink, no matter the color, refer to the unit itself for status. It may be time to change the fi lters, empty the dirt receptacle and/or have the motor(s) inspected.
#)
2#5)4
%!
S RES
Reset
LED
Low voltage
Blinking green
• We suggest you clean the fi lters and empty the dirt receptacle.
Blinking amber
• We suggest that you change the fi lters.
Blinking red
• We strongly suggest you change the fi lters (if it was not done previsously) and have an authorized service center inspect the motor(s). A tune-up may be required.
Blinking green / amber / red
• It is time to bring your unit to an authorized service center. Your unit has accumulated a considerable number of hours, and may require maintenance. A complete inspection is therefore strongly recommended.
To reset the electronic timing board
• Hold the reset switch for 10 seconds.
Operating Instructions
Integrated System Monitor
(DL300 only)
Your central vacuum unit is equipped with an electronic timing device which will recommend by a series of light emitting diodes (LEDs) proper maintenance of your vacuum system. These signals are only suggestions and will do not indicate a problem with your vacuum system. They will not stop or hinder the use of the vacuum.
When you initially plug in your vacuum, the LEDs will signal “OK”. Then, according to the number of hours the system has been use the LEDs will suggest the proper preventive maintenance.
OK, system is operational
Empty receptacle and clean fi lters
Change the carbon dust fi lter
Have the vacuum power unit inspected by an authorized service center
RESET – press to stop fl ashing diodes and reset the electronic timing device.
Remote System Monitor
(Optional — DL300 only)
Installed in a strategic location in your home, it provides the same information as the Integrated System Monitor. Once you have reset the electronic timing device
(on the unit itself), the remote monitor will once again signal “OK”.
Operating Instructions 21
22
Cyclo Vac Attachments
Oval Dusting Brush
Use just about anywhere: on lamps & lamp shades, blinds, shelves, decorative trims
Upholstery Brush
With removable bristles, use to clean all upholstered furniture such as sofas, chairs, and mattresses.
Crevice Tool
Use in narrow spaces, nooks and crannies, such as heating ducts, between sofa cushions, and between window panes.
Floor Brush
For use on all types of fl ooring: hardwood, ceramic or even small carpets.
Carpet Brush (optional)
Specially designed for small carpets and area rugs, it cleans down deep.
Operating Instructions
Cyclo Vac Attachments
Hose Holder
In addition to conveniently holding your hose, it’s specially designed to allow the storage of your fl oor brush on the telescopic wand, without crushing the brush bristles.
Telescopic Wand
It’s easily adjusted to the desired height. Simply depress the button, slide the wand to the desired length, and release the button for it to lock into position. Convenient button-lock mechanisms prevent the wand from slipping off the hose handle.
Attachment Holder
Made of durable vinyl, it conveniently holds all your accessories. Hang it on your hose holder, to keep all accessories at hand.
push button here
Operating Instructions 23
Motor
Please note that Cyclo Vac motors do not require lubrication. Each motor contains two carbon brushes which will wear normally, and may eventually require replacement. For warranty purposes, this should be done by an authorized service center. Brush life is affected by the number of hours used, frequency of start-ups and shut-downs, humidity, altitude, and temperature. In order to avoid damage to the motor itself, brushes should be replaced before they are completely worn out. We therefore recommend that you have your unit and motors inspected by a service center every 5-6 years.
Dirt Receptacle
(Except E100 Model)
Occasional maintenance of the dirt receptacle is necessary to ensure constant, lasting performance. We recommend that it be emptied at least every season, depending on frequency of use. To empty the dust receptacle, fi rst disconnect your vacuum cleaner from its power source. Then release the two clamps, lower and empty the recipient, then replace it and seal by refastening the metal clamps.
Disposable Bag & Filter
(E100 Model Only)
24
Change the bag when the one in place is full. Frequency will depend on the use of the unit.
Line-up the notches in the bag collar with the tabs on adaptor (fi gure 17).
Insert the bag as far as the retention ring, to ensure airtightness.
retention ring
The disc-shaped fi lter (fi gure 18), located between the dust bag and the motor, should be changed once for every three bags (45 hours of use), or more often as needed.
Use only genuine Cyclo Vac replacement bags. Failure to do so could void the warranty on your vacuum unit.
Type 3 Bag
Part Number: TDSAC43C fi gure 17 fi gure 18
Maintenance
We recommend regular maintenance of the fi ltration system, in order to ensure your central vacuum’s maximum performance.
Your Cyclo Vac central vacuum is equipped with two fi lters. An anti-clogging fi lter
(thin fabric) stops the larger particles, and a Cyclofi ltre (thick fabric) catches the microscopic particles and is treated with Ultra-Fresh* to prevent the growth of mold, fungus and bacteria. Both fi lters are washable in cold water (no bleach). Dry at low temperature.
To remove the fi lters, fi rst remove the dust receptacle (fi gure 19), then use the straps at the base of the fi lters to withdraw them
(fi gure 20). We recommend that you clean the anti-clogging fi lter (thin fabric) every time you empty the dust receptacle. You may either shake it out, or wash it. The
Cyclofi ltre (thick fabric) should be cleaned after four anticlogging fi lter cleanings, or approximately once a year.
It is important that both fi lters be completely dry before they are reinstalled.
They should be carefully installed in the support grooves (fi gure 21) on the fi lter frame to ensure adequate protection for the motor. Install the Cyclofi ltre (thick fabric) fi rst, and the anticlogging fi lter (thin fabric) over it.
Before replacing the fi lters, inspect them for tears or punctures. Do not reinstall damaged fi lters.
Filters
(Except E100 Model) fi gure 19 fi gure 20 fi gure 21
*Ultra-Fresh is a trademark of Thomson Research Associates.
Maintenance 25
26
Carbon Dust Filter
(Patent pending)
(E300 and DL300 Only)
We recommend that you change this fi lter once for every three maintenances of the dirt receptacle (see page 26). For the DL300, the integrated monitor will indicate when to change this fi lter. These indications are provided by an electronic timing board, only as a reference guide.
To do so:
1. Unlatch the opening on the carbon fi lter case and gently fl ip it upward (fi gure 22).
2. Remove the used fi lter, and discard
(fi gure 23).
3. Insert the new fi lter. When doing so, please ensure that the arrow printed on the fi lter itself points outwards (fi gure 24).
4. Close casing opening, and latch.
fi gure 22 fi gure 23 fi gure 24
Maintenance
General Information
If the vacuum unit does not work, check the fuse or breaker on the unit and/ or in the electrical panel in your home, and replace any defective part(s) as deemed necessary. Please verify that the unit has been installed properly, according to the instructions in this manual.
Your vacuum cleaning system is designed to collect everyday dry matter
(dust). It is approved by authorized testing agencies for dry use only. Do not use on wet surfaces.
Should you accidentally vacuum liquids, immediately unplug the unit from the electric outlet, then empty and wipe the dust recipient with a dry cloth. Then operate the system from the vacuum inlet through which you vacuumed the liquid, in order to eliminate all moisture in the piping system.
We strongly recommend against vacuuming abrasive materials such as cement, plaster and gyproc dust. This fi ne dust could work its way into the motor, causing considerable damage. Should you do so inadvertently, immediately clean the fi lters and, as a precautionary measure, contact your authorized service center to determine the extent of the damage to the unit.
Remember that in order for your warranty to remain valid, maintenance of the motor and repairs to the unit itself must be carried out by an authorized service center, using original Cyclo Vac or Trovac parts.
Troubleshooting 27
28
Troubleshooting
P ROBLEM
Decrease in suction strength
P OSSIBLE CAUSE C ORRECTIVE ACTION
Dirt recipient / Bag is full Empty dirt recipient / change bag (see page
25).
Dirt recipient is not properly attached
Check clamps holding dirt recipient, to make sure they are tight, and dirt recipient is aligned.
Filters need cleaning / replacing
Motor guard screen is blocked
Remove, shake and/or wash fi lters or replace them (depending on model) before reinstalling them in the unit (see page 26).
Remove fi lters, and check the guard screen
(which separates the motor from the fi ltration compartment) for blockage. Ensure fi lters are always properly installed, to prevent this problem from happening again.
Open vacuum inlet Close all vacuum inlets not in use.
Exhaust line is clogged Verify that no object is blocking the exhaust.
Troubleshooting
Troubleshooting
P ROBLEM
Decrease in suction strength (cont.)
P OSSIBLE CAUSE
Blocked hose
C ORRECTIVE ACTION
Plug the handle end of the hose into the suction inlet, thus reversing the suction in the hose.
Cover the gap around the handle, to ensure suitable suction strength, and ensure contact with inlet contacts to start the unit. This should clear the hose.
Obstruction in the piping system
Remove the screw from the air intake connector, to free the central vacuum unit from the piping system (see fi gure
3 on page 8). Start the unit by plugging the hose into a vacuum inlet. By placing your extended hand over the air intake opening on the unit, check the suction strength on the unit itself.
If suction strength is normal, the obstruction is in the piping system.
If suction strength is diminished or completely absent, have the unit checked by an authorized service center.
If none of these suggestions restore suction strength, contact your authorized service center.
Troubleshooting 29
Troubleshooting
30
P ROBLEM
Vacuum will not start
P OSSIBLE CAUSE
The electrical power is not connected properly
Low voltage wire not connected properly
C ORRECTIVE ACTION
Ensure that the power cord is plugged into a dedicated grounded electrical outlet, according to specifi cations on pages
13 and 14.
Verify the low voltage wires, make sure they are properly inserted into the low voltage inlet, as per instructions on page 15.
Faulty vacuum inlet
Start the vacuum unit from other inlets in your home, to identify the defective inlet.
Unit circuit breaker is off
Press the reset button to reset the unit circuit breaker. If unit restarts and automatically shuts off shortly after, contact an authorized service center.
In-house circuit breaker is off
Reset the circuit breaker in your electrical panel.
Verify that your central vacuum unit is connected on a dedicated grounded circuit (see pages 13 and 14).
Defective on/off hose the vacuum inlet. If unit starts, have the vacuum hose checked by a certifi ed service center.
Troubleshooting
Troubleshooting
P ROBLEM
Vacuum will not stop
P OSSIBLE CAUSE C ORRECTIVE ACTION
Hose improperly inserted into vacuum inlet
Ensure that the hose end is properly placed in the vacuum inlet: the tab on the hose should fi t into the slots on the inlet, to ensure adequate contacts for the hose switch to function (see page 18).
Defective on/off hose
Low voltage wire not connected properly
If the hose is properly placed in the vacuum inlet, and the unit continues running despite the fact that the hose switch is in the “off” position, have the hose checked by a service center.
While vacuum is on, unplug low voltage wires from unit. If vacuum stops, there’s a faulty low voltage wire.
Contact your installer or authorized service center.
Troubleshooting 31
32
Warranty Information
LIMITED LIFETIME WARRANTY
Your Cyclo Vac vacuum system is protected by a lifetime warranty. We guarantee that the unit canister will be exempt of any material or manufacturing defect.
This warranty is valid from the date of purchase, for as long as you are the original owner, and the system remains at its original place of installation.
The motors and electrical components of both E and DL series are entirely guaranteed for a period of 5 years. As for our DL series, in addition to the
5 year warranty, the motors and electrical components are guaranteed at 50 % for an additional 5 year period. Our authorized service center will repair or replace (at Cyclo Vac’s discretion) the defective part or parts, free of labor costs, for a period of 5 years. For the DL series, labor costs are covered at 50 % for an additionnal 5 years.
MODEL
E Series
DL Series
Cyclo Vac Warranty
Motors and Electrical Components
Y EAR
1 to 5
1 to 5
6 to 10
P ARTS
100 %
100 %
50 %
L ABOR
100 %
100 %
50 %
In order to maintain your warranty, all repairs must be made by an authorized
Cyclo Vac service center, with original Cyclo Vac or Trovac parts. Failure to do so could void the warranty.
This warranty excludes normal wear and tear of certain parts such as fi lters, damages caused (according to Cyclo Vac) by abusive use (ex.: drywall dust, water, etc.), commercial use, the lack of appropriate maintenance, inadequate installation, negligence, natural disasters, accidents, and acts of God.
ONE YEAR SATISFACTION GUARANTEE
We are certain you’ll be completely satisfi ed with your Cyclo Vac central vacuum system. For one year following the date of purchase, if the vacuum unit does not meet your expectations, return it to your local Cyclo Vac service center for a complete refund or credit towards the purchase of another Cyclo Vac model. This warranty applies only to the vacuum power unit.
Warranty Information
Warranty Information
THREE YEAR WARRANTY ON CYCLO VAC RECOMMENDED* ATTACHMENTS
All Cyclo Vac recommended attachments* are guaranteed for three years, subject to certain conditions. If during this three year period, an accessory presents a manufacturing defect, return it to the nearest authorized Cyclo Vac service center along with a copy of your invoice (clearly indicating the attachments purchased), and we will repair or replace the part according to the conditions of the warranty.
This warranty does not cover normal wear and tear of components such as: belts, brushes, rollers and their components, nor abusive use. It is valid only for normal domestic use.
*Your Cyclo Vac recommended attachments are clearly identifi ed by a Cyclo Vac logo. Any other attachment, even if purchased at a Cyclo Vac sales center at the same time as your power unit, is not covered by the 3 year Cyclo Vac warranty.
This warranty is valid for domestic use only. This warranty is not a modifi cation but an addition to warranties required by law. Any claim relative to this warranty
must be accompanied by the original invoice. Any changes or modifi cations made to the product may invalidate this warranty. Transportation and service calls are excluded . This warranty is non transferable.
Keep all payment records (bill of sale, delivery slip). The date on these records establishes the warranty period. Should warranty service be required, you must show proof of purchase. If proof of purchase cannot be supplied, the warranty period will be determined from the date of manufacture of the product.
Cyclo Vac shall not be held responsible for any consequential, incidental, or special damages arising from the use of this central vacuum.
Warranty Information 33
WEEE Directive
Important Environmental Information – European Economic Area only
This appliance has been assessed in accordance with the European Parliament
Directive on Waste Electrical and Electronic Equipment, usually referred to as the
WEEE Directive.
The WEEE Directive requires that the appliance be disposed of at the end of its useful life in an environmentally responsible manner. Parts and materials should be re-used or re-cycled in order that the use of new resources and amount of waste going for landfi ll can be minimised.
The WEEE Directive stipulates that the supplier should collect the used item without cost to you. Please inform the supplier of your wish to have the old appliance collected when ordering the replacement.
If you wish to dispose of the appliance yourself, do not mix it with unsorted municipal waste. The crossed-out wheeled bin symbol on the unit label (fi gure 25) indicates this requirement. You must ensure that the appliance is disposed of at an authorised treatment facility. Details can be obtained from your local council.
fi gure 25
34 Warranty Information
WWW.CYCLOVAC.COM
Head Offi ce / Siège social / Ofi cina Central
CANADA
3, rue Marcel-Ayotte
Blainville (Québec) J7C 5L7
Tel. : (450) 434-2233 • Fax : (450) 434-6111 [email protected]
1 888 77CYCLO
Distribution Centers / Centres de distribution / Centros de distribución
CANADA
1260, Lakeshore Road
Missisuaga, ON L5E 3B8
1 800 665-2500
USA
3873 Airport Way
Bellingham WA 98226
1 800 665-2500
CANADA
19578, 55A Avenue
Surrey, BC V3S 8P8
(604) 514-7005
1 800 665-2500
USA
5460, Florin Perkins Road
Sacramento CA 95826
1 800 325-3434
1 916 361-7491
EUROPE
16, rue du Stade
44170 Treffi eux
Tel. : + 33 (0) 2 40 51 44 60 • Fax : + 33 (0) 2 40 51 42 24 [email protected]
Nº vert: 0800 800 393
advertisement
Key Features
- Powerful suction to remove dirt and debris from all types of surfaces
- Progressive start and delayed stop to prevent clogs and extend motor life
- Integrated system monitor to track performance and notify you of any issues
Frequently Answers and Questions
How does the progressive start and delayed stop feature work?
What does the integrated system monitor do?
How often should I change the filter?
Related manuals
advertisement
Table of contents
- 6 Preface
- 6 Schematic – E100
- 7 Schematic – Other Models
- 8 Installation
- 8 Unit Installation
- 9 Dos & Don’ts
- 12 Muffler Installation
- 13 Electric Connections
- 14 Grounding Instructions
- 15 Low Voltage Connections
- 16 Installing the Remote Monitor
- 18 Operating Instructions
- 18 Hose Hook-up & Inlets
- 19 Speed Variation Hose
- 19 Progressive Start and Delayed Stop
- 20 Maintenance Suggestions Module
- 21 Integrated System Monitor
- 21 Remote System Monitor
- 22 Cyclo Vac Attachments
- 24 Maintenance
- 24 Motor
- 24 Dirt Receptacle
- 24 Disposable Bag & Filter
- 25 Filters
- 26 Carbon Dust Filter
- 27 Troubleshooting
- 27 General Information
- 28 Decrease in suction
- 30 Vacuum will not start
- 31 Vacuum will not stop
- 32 Warranty Information
- 32 Limited Lifetime Warranty
- 32 One Year Satisfaction Guarantee
- 33 Warranty on CycloVac Attachment