Paradyne Hotwire 8375 Installation instructions
Advertisement
Advertisement
Hotwire
®
ATM Line Cards
Models 8335, 8355, 8365, 8375, and 8385
Installation Instructions
Document Number 8335-A2-GZ40-60
March 2005
Contents
Software and Firmware License Agreement .................................................
Product Documentation Online .....................................................................
Connecting to the ATM Network ...................................................................
Connecting to an MDF or ADSL POTS Splitter ............................................
Logging In to the MCC Card .........................................................................
Configuring the ATM Parameters ..................................................................
Configuring ATM Cross Connection ..............................................................
Asynchronous Terminal Interface Menu ....................................................... 10
Warranty, Sales, Service, and Training Information ...................................... 11
8335-A2-GZ40-60 March 2005 1
Software and Firmware License Agreement
ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS,
YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE
PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU SHOW YOUR
ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.
IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS
LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS
ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE
LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE
LOCATION FROM WHICH IT WAS SHIPPED TO YOU, AS APPLICABLE, AND YOU
WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT
PURCHASED BY YOU.
The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmware (individually or collectively the “Software”) incorporated into the Paradyne product (the “Product”) purchased by you and any derivatives obtained from the Software, including any copy of either. If you have executed a separate written agreement covering the Software supplied to you under this purchase, such separate written agreement shall govern.
Paradyne Corporation (“Paradyne”) grants to you, and you (“Licensee”) agree to accept a personal, non-transferable, non-exclusive, right (without the right to sublicense) to use the Software, solely as it is intended and solely as incorporated in the Product purchased from Paradyne or its authorized distributor or reseller under the following terms and conditions:
1. Ownership: The Software is the sole property of Paradyne and/or its licensors.
The Licensee acquires no title, right or interest in the Software other than the license granted under this Agreement.
2. Licensee shall not use the Software in any country other than the country in which the Product was rightfully purchased except upon prior written notice to
Paradyne and an agreement in writing to additional terms.
3. The Licensee shall not reverse engineer, decompile or disassemble the
Software in whole or in part.
4. The Licensee shall not copy the Software except for a single archival copy.
5. Except for the Product warranty contained in the manual, the Software is provided “AS IS” and in its present state and condition and Paradyne makes no other warranty whatsoever with respect to the Product purchased by you.
THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES,
WHETHER EXPRESS OR IMPLIED, OR ORAL OR WRITTEN, INCLUDING
WITHOUT LIMITATION: a.
Any warranty that the Software is error-free, will operate uninterrupted in your operating environment, or is compatible with any equipment or software configurations; and b.
ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT
LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT.
Some states or other jurisdictions do not allow the exclusion of implied warranties on limitations on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from one state or jurisdiction to another.
6. In no event will Paradyne be liable to Licensee for any consequential, incidental, punitive or special damages, including any lost profits or lost
2 March
savings, loss of business information or business interruption or other pecuniary loss arising out of the use or inability to use the Software, whether based on contract, tort, warranty or other legal or equitable grounds, even if
Paradyne has been advised of the possibility of such damages, or for any claim by any third party.
7. The rights granted under this Agreement may not be assigned, sublicensed or otherwise transferred by the Licensee to any third party without the prior written consent of Paradyne.
8. This Agreement and the license granted under this Agreement shall be terminated in the event of breach by the Licensee of any provisions of this
Agreement.
9. Upon such termination, the Licensee shall refrain from any further use of the
Software and destroy the original and all copies of the Software in the possession of Licensee together with all documentation and related materials.
10. This Agreement shall be governed by the laws of the State of Florida, without regard to its provisions concerning conflicts of laws.
Hotwire ATM Line Cards
The Hotwire
®
8335, 8355, 8365, 8375, and 8385 Asynchronous Transfer Mode
(ATM) Line Cards are circuit boards mounted in an 8620 or 8820 Broadband Loop
Carrier (BLC), used to transport ATM cells at high speeds over a single twisted-pair connection.
Model 8335 supports Symmetric Digital Subscriber Line (SDSL).
Model 8355 supports ReachDSL
®
2.2 concurrent with POTS.
Model 8365 supports Asymmetric Digital Subscriber Line (ADSL) concurrent with POTS.
Model 8375 supports ReachDSL+, a technology that combines ADSL features and performance with the unique capabilities of Paradyne’s ReachDSL.
Model 8385 supports Single-pair High-speed Digital Subscriber Line
(SHDSL).
Product Documentation Online
Complete documentation for this product is available at www.paradyne.com.
Select Support
→ Technical Manuals.
Document Number Document Title
Primary document for this product:
8335-A2-GB20 Hotwire ATM Line Cards, Models 8335, 8355, 8365, 8375, and
8385, User’s Guide
Reference documents:
6050-A2-GZ40 Hotwire Central Office Universal POTS Splitter, Models 6050 and
7020, Installation Instructions
8335-A2-GZ40-60 March 2005 3
Document Number Document Title
6390-A2-GN10
8000-A2-GB22
Hotwire ReachDSL Modem, Model 6390 with Inline Phone Filter,
Installation Instructions
Hotwire Management Communications Controller (MCC) Card,
IP Conservative, User’s Guide
8021-A2-GB20
8021-A2-GZ40
8620-A2-GN20
8820-A2-GN20
Hotwire Shelf Concentration Module (SCM) Card User’s Guide
Hotwire Shelf Concentration Module (SCM) Card Installation
Instructions
8620 Broadband Loop Carrier Installation Guide
8820 Broadband Loop Carrier Installation Guide
To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000.
Installation Overview
Installation and configuration of the ATM Line Card consists of:
Installing the card in the BLC.
Connecting to a Main Distribution Frame (MDF).
Connecting to the DS3, OC3, E3, or T1/E1 uplink.
Providing initial unit identity information or changing existing identity information.
Configuring your unit using the Configuration Edit menus.
Be sure to register your warranty at www.paradyne.com/warranty.
Planning the Installation
Review the following list to help plan for the installation.
❑
Obtain the applicable cables; refer to Cables You Need on page 5.
❑
Make sure the chassis is installed and power is supplied to it.
❑
After the ATM Line Card is installed, there are configuration procedures that
must be performed before you can begin to use it. Refer to the Hotwire ATM
Line Cards, Models 8335, 8355, 8365, 8375, and 8385, User’s Guide for
detailed configuration procedures.
4 March
Cables You Need
The following standard cables are used with this product:
For the DSL network connection: Plug-ended Telco 50-pin cable for connection from the chassis rear connector to the MDF or other demarcation point. Refer to the 8620 or 8820 BLC Installation Guide and, if applicable, the documentation that came with your POTS splitter for more information.
For the ATM Uplink: Refer to the
Hotwire Shelf Concentration Module (SCM)
for cable specification information.
For more information refer to Connector Pin Assignments in the Hotwire ATM Line
Cards, Models 8335, 8355, 8365, 8375, and 8385, User’s Guide .
Installing DSL Cards
!
HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative.
An ATM Line Card can be installed in, removed from, and replaced in an 8620 or
8820 BLC without disrupting service to the other cards in the chassis.
Procedure
To install the ATM Line Card:
1. Determine in which slot the unit will be installed. Verify that cards in adjacent slots have been fastened.
2. Remove the filler plate from the installation slot and store for possible later use.
8335-A2-GZ40-60 March 2005 5
3. Holding the ATM Line Card vertically with component side facing right, insert it into the top and bottom card guides.
POWER
ALARMS
A B
Fan Major Minor
SYSTEM
OK
Alm
Test
TX
RX
Coll
DSL P
ORT
3
4
1
2
DSL
SYSTEM
OK
Alm
Test
ETHERNET
TX
RX
Coll
MCP
POWER ENTRY MODULE
RIGHT UNIT: LINE B
WARNING! POWER MUST BE DISCONNECTED A
T THE SOURCE
POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B
CLOCK
A
SERIAL
MCC
AC
ALARM
2
4 6
8 A
10 12
14 16
18
SERIAL
SMCM
ALARM
1 3
5 7
9 B
11 13
15 17
00-16709
CAUTION:
Do not force the unit into the slot. This could damage the backplane connectors. If the card does not seat properly, remove the card and reinstall it. If it still does not seat properly, call your service representative.
4. Slide the unit into the slot until the power and network connectors seat firmly in the mating connectors on the backplane.
The unit performs a power-on self-test. All of the LEDs turn ON and OFF briefly. When the self-test is completed successfully, the SYSTEM OK LED begins to pulse.
If the LED is not pulsing, notify your service representative.
5. Secure the unit by fastening the screws at each end of the faceplate.
Connecting to the ATM Network
The connection to the ATM network is made through the Shelf Concentration
Module (SCM), another card in the BLC. Depending on the model, the SCM
supports a DS3, OC3, E3, or T1/E1 connection. See the Hotwire Shelf
Concentration Module (SCM) Card User’s Guide for more information.
6 March
Connecting to an MDF or ADSL POTS Splitter
You can connect the ATM Line Card to an MDF or other demarcation point. Do not connect the Model 8335 or 8385 to a POTS splitter. Refer to the 8620 or 8820 BLC
Installation Guide for more information.
Refer to Connector Pin Assignments in the
Hotwire ATM Line Cards, Models 8335,
8355, 8365, 8375, and 8385, User’s Guide for pinouts of the BLC ports.
Procedure
To connect the chassis containing the unit to an MDF:
1. Determine the slot number the ATM Line Card was installed in.
2. Plug the Telco 50-pin cable into the appropriate numbered port on the back of the BLC.
3. If a ferrite and cable tie are included in the package with your ATM line card, attach the ferrite to the Telco cable, then secure it with the cable tie.
4. Dress the cable to the side the connector is nearest.
5. For the Model 8335, 8355, 8365, 8375, or 8385 with no POTS service:
— Attach the other end of the cable to the appropriate MDF or demarcation point.
For the Model 8355, 8365, or 8375 using an ADSL POTS splitter:
— Attach the other end of the cable to the XDSL interface of the Corning
Cable Systems (formerly Siecor) ADSL POTS Splitter Rack-Mount Shelf or the Hotwire 6050 Central Office Universal POTS Splitter. Refer to the document that came with the POTS splitter for the additional connections.
NOTE:
If you are connecting the Telco 25-pair, 50-pin cable to an MDF, a converter may be necessary for terminating the other end of the cable on a punchdown block before cross-connecting to an MDF.
8335-A2-GZ40-60 March 2005 7
Front Panel LEDs
The following table describes the meaning and states of the LEDs on the front panel.
SYSTEM SYSTEM SYSTEM
AT
M
B
U
S
TX
RX
LOC
OK
Alrm
Test
ATM B
U
S
TX
RX
LOC
OK
Alrm
Test
AT
M
B
U
S
TX
RX
LOC
OK
Alrm
Test
DSL POR DSL POR DSL POR
POR
T
1/9
T
2/10
3/11
4/12
5/13
6/14
7/15
8/16
POR
T
9/21
10/22
11/23
12/24
POR
T
1/13
T
2/14
3/15
4/16
5/17
6/18
7/19
8/20
POR
T
9/21
10/22
11/23
12/24
POR
T
5
6
7
8
1
2
3
4
T
11
12
9
10
ALT BANK ALT BANK
9-16
1-8
13-24
1-12
ATM
SDSL
8335
ATM
ReachDSL
8355
G.DMT
G.Lite
8365
00-16661 02-17210 00-16719
Type
SYSTEM
LED
OK
LED is . . . *
Green, On
Off
Green,
Pulsing
Green,
Fast Blinking
Amber, On
Indicating . . .
Card failure. System processing functions have stopped.
No power to card.
Card functioning normally.
Firmware download needed.
ATM BUS
Alrm
Test
TX
RX
Off
Amber, On
Off
Amber,
Fast Blinking
Off
Green,
Fast Blinking
Off
Green,
Fast Blinking
Amber, On
Alarm is present on the card. ATM interface is not being detected.
Normal operation, no alarms.
Test in progress.
Normal operation, no tests.
Self-test is in progress.
Inactive.
Cells are being transmitted.
Inactive, link down.
Cells are being received.
DSL PORT
8335
8365
24-Port
Models
ALT BANK
8335
24-Port
Models
LOC
Off
1/9–8/16
1–12
1/13–12/24
Green, On
Off
Green,
Slow Blinking
Green,
Fast Blinking
Off
9–16
1–8
13–24
1–12
Amber,
Fast Blinking
Loss Of Clock. ATM bus clock signal is not present.
Normal operation.
Good signal, unit is trained.
Port is disabled.
Port is in test, or is down.
Port is training.
The ports not currently displayed by the port status LEDs are functioning normally or are disabled.
One of the ports not currently being displayed by the port status LEDs is down, in test, or in training mode.
* Pulsing: LED turns off momentarily once per second.
Slow Blinking: LED turns on momentarily once per second.
Fast Blinking: LED turns off and on in equal duration 4 times per second.
The 8375 and 8385 front panels, not displayed, have the same LEDs and designations as the 8355.
8 March
Logging In to the MCC Card
You can log in to the management card using either a local VT100- compatible terminal or a remote Telnet connection.
After you enter your user ID and password, the system displays the Main Menu.
See the
Hotwire Management Communications Controller (MCC) Card,
IP Conservative, User’s Guide for information about selecting the unit from the
card selection screen.
Entering Card Information
After accessing your line card for the first time, use the Card Information screen to configure basic information about the card. To access the Card Information screen, follow this menu selection sequence:
Configuration
→
Card
→
Card Info (A-A-A)
Configuring the DSL Ports
You can set the rate of the DSL ports from the DSL Port Configuration screen. To access the DSL Port Configuration screen, follow this menu selection sequence:
Configuration
→
Physical Ports
→
DSL Ports (A-B-B)
Configuring the ATM Parameters
You can configure ATM parameters from the ATM Parameters screen. To access the ATM Parameters screen, follow this menu selection sequence:
Configuration
→
ATM Switch
→
ATM Parameters (A-E-A)
Configuring ATM Cross Connection
You can configure VC connections from the line card to the endpoint with the ATM
Cross Connect screen. To access the ATM Cross Connect screen, follow this menu selection sequence:
Configuration
→
ATM Switch
→
ATM Cross Connect (A-E-B)
8335-A2-GZ40-60 March 2005 9
Asynchronous Terminal Interface Menu
The following diagram shows the menu paths to the functions available through the asynchronous terminal interface.
Main
A - Configuration
A - Card
A- Card Info
B- Time/Date
C- NVRAM Clear
D- Config Loader
E- Card Reset
F- Download Code
A- Download
B- Apply
G- Spectrum Mgt 1
B - Physical Ports
A- Reserved - N/A
B- DSL Ports
C- ATM PHY Layer 4
C - Interfaces - N/A
D - Reserved - N/A
E - ATM Switch
A- ATM Parameters
B- ATM Cross Connect
C- ATM Traffic Prof
D- Clear X Connects
E- Rate Shaping 1
F - SN Configuration
A- SN Config
B- Config SN Mgt 2
B - Monitoring
A - Card Status
A- Card Info
B- Time/Date
C- Syslog
C - Applications
B - Physical Ports
A- Active List
B- Reserved - N/A
C- ATM PHY Layer 4
D- DSL Link Perf Sum
E- Reserved - N/A
F- DSL Error Stats 3
C - Interfaces - N/A
D - Reserved - N/A
E - ATM Switch
A- ATM Parameters 4
B- ATM Cross Connect
C- ATM Traffic Prof
D- ATM Aggr Stats
E- VCC Perf Stats
F- Unknown Cell Log
G- ATM Conn Status
F - SN Information
A- SN Information
B- SN Mgt 2
4
4
3
4
1
2
D - Diagnostics
A - Selftest
B - Alarms
C - ATM Ping
A- ATM Ping Config
B- ATM Ping Summary
D - Reserved - N/A 1
E - Reserved - N/A 1
F - Line Loopback 1
Applies to Model 8385 Only
Applies to Models 8335 and 8385 Only
Applies to Models 8365, 8375, and 8385 Only
Applies to Models 8335, 8365, 8375
and 8385 Only
04-17050-02
Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or
Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.
(Be sure to register your warranty at www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo,
FL 33773, or send e-mail to [email protected]. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
Trademarks
Hotwire and ReachDSL are registered trademarks of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.
Copyright 2005 Paradyne Corporation. Printed in U.S.A.
8335-A2-GZ40-60 March 2005 11
*8335-A2-GZ40-60*
*8335-A2-GZ40-60*
12 March

Download
Advertisement