Windsor 10066700 is an electric carpet extractor designed for commercial use. It applies cleaning solution to the carpet and then vacuums the soiled water back into the 17-gallon recovery tank, leaving carpets cleaner and faster-drying. Its 150 PSI pump provides powerful cleaning performance, while its compact size and easy-to-use controls make it ideal for cleaning smaller areas or spots.
Advertisement
Advertisement
150 PSI - 17 Gallon
Operating instructions (ENG)
MODELS:
NMWU2215N
10066700
86330780-C
04/21/11
Read these instructions before using the machine.
Machine Data Log/Overview
OVERVIEW
The Dominator is an electric powered carpet extractor intended for commercial use. This appliance applies a cleaning solution to the carpet and then vacuums the soiled water back into the recovery tank.
2
Warranty Registration
Thank you for purchasing a Windsor product. Warranty registration is quick and easy.
Your registration will allow us to serve you better over the lifetime of the product.
To register your product go to : www.windsorind.com/WarrantyRegistration.aspx
For customer assistance:
1-800-444-7654
86330780 DOMINATOR 150 PSI
Machine Data Log/Overview. . . . . . . . . . . . . . . . . . . 2
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
How to Use This Manual . . . . . . . . . . . . . . . . . . . . . . 4
Safety
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . 5
HAZARD INTENSITY LEVEL . . . . . . . . . . . . . . . . . . 6
Safety Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Grounding Instructions . . . . . . . . . . . . . . . . . . . . . . . 8
Table of Contents
PARTS
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Suggested Spare Parts . . . . . . . . . . . . . . . . . . . . . 38
Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Operations
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . 9
Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Machine Operation . . . . . . . . . . . . . . . . . . . . . . . . . 11
Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pre-Run Inspection . . . . . . . . . . . . . . . . . . . . . . . . . 12
Equipment Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Maintenance
Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . 14
Daily/Regular Maintenance. . . . . . . . . . . . . . . . . . . 14
Vacuum Motor Replacement . . . . . . . . . . . . . . . . . 15
Solution Pump Replacement . . . . . . . . . . . . . . . . . 16
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
86330780 DOMINATOR 150 PSI 3
How to Use This Manual
This manual contains the following sections:
• How to Use This Manual
• Safety
• Operations
• Maintenance
• Parts List
The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the
MACHINE DATA box which is filled out during the installation of your machine. The MACHINE DATA box is located on the inside of the front cover of this manual.
Model:
Date of Purchase:
Serial Number:
Dealer:
Address:
Phone Number:
Sales Representative:
The model and serial number of your machine is located approximately where shown.
Serial Number
Tag
The SAFETY section contains important information regarding hazardous or unsafe practices of the machine. Levels of hazards are identified that could result in product damage, personal injury, or severe injury resulting in death.
The OPERATIONS section is to familiarize the operator with the operation and function of the machine.
The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition. They are listed in this general order:
• Maintenance
• Lubrication
• Vacuum Motor Replacement
• Solution Pump Replacement
• Troubleshooting
The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information:
• REF – column refers to the reference number on the parts illustration.
• PART NO. – column lists the part number for the part.
• PRV NO. – reference number.
• QTY – column lists the quantity of the part used in that area of the machine.
• DESCRIPTION – column is a brief description of the part.
• SERIAL NO. FROM – If this column has an (*) and a Reference number, see the SERIAL
NUMBERS page in the back of your manual. If column has two asterisk (**), call manufacturer for serial number. The serial number indicates the first machine the part number is applicable to. The main illustration shows the most current design of the machine. When a boxed illustration is shown, it displays the older design.
• NOTES – column for information not noted by the other columns.
NOTE: If a service or option kit is installed on your
machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement parts numbers needed for ordering future parts.
NOTE: The manual part number is located on the
lower left corner of the front cover.
4 86330780 DOMINATOR 150 PSI
Safety
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precaution must always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
This machine is for commercial use.
To reduce the risk of fire, electric shock, or injury:
Connect to a
properly grounded outlet
. See Grounding Instructions.
Do not
leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service.
Use only
indoors. Do not use outdoors or expose to rain.
Do not
allow machine to be used as a toy.
Close attention
is necessary when used by or near children.
Use only as described in this manual. Use only manufacturer's recommended components and attachments.
Do not use damaged electrical cord or plug. Follow all instructions in this manual concerning grounding the machine. If the machine is
not working properly
, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center.
Do not
pull or carry machine by electrical cord, use as a handle, close a door on cord, or pull cord around sharp edges or corners.
Do not
run machine over cord.
Keep
cord away from heated surfaces.
Do not
unplug machine by pulling on cord. To unplug, grasp the electrical plug, not the electrical cord.
Do not
handle the electrical plug or machine with wet hands.
Do not
operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow.
This machine is intended for cleaning carpet only.
Do not
vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
This machine is not suitable for picking up health endangering dust.
Turn off all controls before unplugging.
Machine can cause a fire
when operating near flammable vapors or materials. Do not operate this machine near flammable fluids, dust or vapors.
This machine is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices for more than normal housekeeping purposes.
Maintenance and repairs must be done by qualified personnel.
If foam or liquid comes out of machine, switch off immediately.
SAVE THESE INSTRUCTIONS
86330780 DOMINATOR 150 PSI 5
Safety
The following symbols are used throughout this guide as indicated in their descriptions:
HAZARD INTENSITY LEVEL
There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY.
The level of hazard intensity is determined by the following definitions:
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage.
FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.
Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel.
FOR SAFETY:
DO NOT OPERATE MACHINE:
Unless Trained and Authorized.
Unless Operation Guide is Read and understood.
In Flammable or Explosive areas.
In areas with possible falling objects.
WHEN SERVICING MACHINE:
Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine.
Use only manufacturer approved replacement parts.
6 86330780 DOMINATOR 150 PSI
Safety
Safety Labels
NOTE: These drawings indicate the location of safety labels on the machine. If at any time the labels
become illegible, promptly replace them.
Label Warning
86244300
PRV # 500955
WARNING!
FOR YOUR PROTECTION USE A
GROUND FAULT CIRCUIT INTERRUPTER
Label Circuit Interrupter
86200570
PRV # 170-41
86330780 DOMINATOR 150 PSI 7
Safety
Grounding Instructions
THIS PRODUCT IS FOR COMMERCIAL
USE ONLY.
ELECTRICAL:
In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit. The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.
EXTENSION CORDS:
If an extension cord is used, the wire size must be at least one size larger than the power cord on the machine, and must be limited to 50 feet (15.5m) in length.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks like the plug in "Fig.
A". A temporary adaptor that looks like the adaptor in
"Fig. C" may be used to connect this plug to a 2-pole receptacle as shown in "Fig. B", if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (Fig. A) can be installed by a qualified electrician. The green colored rigid ear, lug, or wire extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover.
Whenever the adaptor is used, it must be held in place by a metal screw.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
8 86330780 DOMINATOR 150 PSI
Technical Specifications
Electrical
Solution Pump
Solution Capacity
Recovery Capacity
Height
Length
Width
Vaccum Motor
Weight- Empty
Weight-Full Solution
Power cord
ITEM
Width
115 Volt, 60 hz, 15A
150 psi
17 Gal
14 Gal
43 inches
32.5 inches
22.5 inches
Dual 2 Stage
120lbs
261 lbs
1 X 25 feet
MEASURE
Length
Operations
Height
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for thier safety.
86330780 DOMINATOR 150 PSI 9
Operations
Controls
1
2
3
4
7
1.
Vacuum Accessory Tool Hook-up
2.
Solution Pump Switch
3.
Vacuum 1 Switch
4.
Vacuum 2 Switch
6
5
5.
Breaker for Vacuum 2
6.
Breaker for Vacuum 1
7.
Solution Accessory Tool Hook-up
10 86330780 DOMINATOR 150 PSI
Operations
Machine Operation
Care must be exercised in the use of all chemicals.
Chemicals are poisonous and can pose a health risk.
Read and follow manfacturers instructions regarding dangers and correct usages.
Only use chemicals approved for use with this machine. Use of non-compatible chemicals may cause machine damage and will not be covered under the warranty. Carefully read ingredients on manfacturer's label before using any product in this machine.
Do not let pump run dry.
The internal parts of the pump used in the machine are suitable for use with most carpet cleaning chemicals.
But they are susceptible to chemical attack from some cleaning substances, such as hydrocarbon solvents and chlorinated bleaches. These non-compatible materials are not of the type used for carpet cleaning.
Chemicals
Suitable Chemicals
• Alkalis
• Detergents
• Hydroxides
• Soaps
• Vinegar
Non-Compatible
• Aldehydes
• Aromatics Hydrocarbons
• SP Butyls
• Carbon Tetrachloride
• Clorox*
• Chlorinated Bleaches
• Chlorinated Hydrocarbons
• Lysol*
• Methyl Ethel Ketone (MEK)
• Perchorethylene (perc)
• Phenolics
• Trichlorethylene
• D-Limonene
Do not let pump run unattended.
*Registered Trademark
86330780 DOMINATOR 150 PSI 11
Operations
Pre-Run Inspection
1.
Check all fittings and connectors for proper assembly.
2.
Check all hoses for leaks. Repair or replace any damaged hoses.
3.
Check power cord(s) for any damage. If damaged, replace.
Equipment Set-up
1.
Plug power cord from machine into properly grounded wall outlet.
2.
Turn vacuum motor switch on and off to make sure there is electrical power at machine.
3.
Connect vac hose to machine. Slide the swivel cuff over the outlet on the tank.
4.
Connect the hose to your machine and wand. Pull back the knurled collar on the quick disconnect coupler and push onto the connection on the chassis. To avoid leaks, check that a positive connection was made.
NOTE: Wand orifice must be equivalent or larger
than an 04 nozzle.
5.
Using a clean container, fill the solution tank with clean hot water. Do not use water over 130°F. Mix in a non-foaming cleaning concentrate for use in hot water extraction machines, following the manufacture's instructions printed on container.
NOTE: When using a powder cleaner, pre-mix with
hot water in a clean container before adding to the solution tank.
6.
Turn pump and vacuum switch(s) to the on position.
Cleaning
Always use defoamer if foaming occurs. Foam will suspend large particles that may damage vacuum(s) as well as allow liquid into the vacuum motor(s) without activating the float shutoff.
1.
Prior to cleaning, make certain that the nozzle is functioning properly.
a.
To check, hold the wand about one foot above the surface to be cleaned and open the wand valve. A full spray should be observed from the nozzle.
b.
If the nozzle is not showing a full spray pattern, adjust nozzle for proper pattern, clean, or replace nozzle.
2.
Normally, chemical is applied on the push stroke of the wand when cleaning. Vacuuming is done on the pull stroke. For heavily soiled carpets the wand may be used in a scrubbing manner, applying chemical in both the push and pull stroke.
3.
When cleaning, keep the working opening (wand mouth) flat on the surface being cleaned. Keep the wand moving when the valve is open.
4.
The shutoff float inside the vacuum tank will impede the vacuum flow when the vacuum tank is full. When this occurs, empty the vacuum tank by opening the dump valve and dispose of the waste in a proper manner.
Once the vacuum tank has been emptied, you may once again proceed with cleaning.
12 86330780 DOMINATOR 150 PSI
Notes:
86330780 DOMINATOR 150 PSI 13
Maintenance
Periodic Maintenance
Twice a month, flush a white vinegar solution (one quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the machine. This will prevent build-up of alkaline residue in the system.
If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow dry.
NOTE: Do not use pins, wires, etc. to clean nozzles
as this could destroy the spray pattern.
Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. The electrical cable must be well insulated and cable connector screw kept tight. If the cable insulation is broken or frayed, repair or replace immediately. Don't take chances with elctrical fire or shock.
Daily/Regular Maintenance
Before making any repairs or adjustments to the machine, disconnect the power cords from the
electrical source.
1.
Empty unused cleaning solution from the solution tank.
2.
Inspect and clean filter screen in solution tank.
3.
Flush pumping system with 1 to 2 gallons of clean water.
4.
After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a
10-1 bleach to water solution. Waste water should be disposed of properly.
Do not allow machine to freeze.
SERVICE SCHEDULE
Check machine for cord damage
Check recovery dome and gasket for damage and cleanliness
Check hoses for wear, blockages, or damage
Check handles, switches, and knobs for damage
Run one gallon of water through system
Clean out recovery tank and check float valve to make sure it moves freely
Clean out solution tank and remove and clean vacuum intake screen
Clean outside of all tanks and check for damage
Run vac motor for at least one minute to allow motor to dry
Store with dome off tank to allow the tank to dry
Check all gaskets for wear and leakage
Check pump pressure; observe spray pattern and check with gauge if necessary
Check and clean solution screen
Check cables for fraying
Check overall performance of machine
Check vac motor carbon brushes
DAILY WEEKLY QUARTERLY
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
14 86330780 DOMINATOR 150 PSI
Only qualified maintenance personnel are to perform the following repairs.
Vacuum Motor Replacement
1.
Turn off all switches and unplug machine.
2.
Remove hardware under front of machine to access component compartment.
3.
Remove vacuum motor cover and disconnect motor wires.
4.
Remove the vacuum motor.
5.
Reverse process to install vacuum motor.
Maintenance
Vacuum Motor Carbon Brushes Replacement
End Cap
Carbon
Brushes
WARNING: The green ground wire must be attached for safe operation. See wiring diagram.
If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.
Important:
These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.
3
8
[9.5mm]
Periodically check the length of the carbon brushes.
Replace both carbon brushes when either is less than
3/8" (9.5mm) long.
86330780 DOMINATOR 150 PSI 15
Maintenance
Solution Pump Replacement
Only qualified maintenance personnel are to perform the following repairs.
PUMP REPLACEMENT KITS
150 PSI
Bypass Valve Kit
86258830
PRV NO. 84161
Diaphragm Kit
86235100
PRV NO. 29206
16 86330780 DOMINATOR 150 PSI
Maintenance
Troubleshooting
PROBLEM
Loss of Power
Electrical shock
Vac motor speed varies or doesn't run
Loss of vacuum
CAUSE
Unit not plugged in
Dead electrical circuit
Faulty power cord
Receptacle not grounded
Internal wiring problem
Vacuum circuit breaker tripped
Faulty vacuum motor
Faulty switch
Loose vacuum dome
Crack in dome or poor joint
Lint or dirt clogging vacuum screen
Loose cuffs on vacuum hose
Vac motor seals leaking
Floor tool vac chamber clogged
Vacuum hose damaged
Recovery tank full / Float ball stuck in the up position
Pump inlet screen plugged
SOLUTION
Connect unit to 3 prong grounded outlet.
Check building circuit breaker or fuse box.
Replace
Contact an electrician to check building's wiring
Have a trained service technician check machine's wiring
Reset Breaker
Replace
Replace
Center and seal dome over tank
Replace or repair using acrylic plastic cement only
With power off clean screen
Tighten cuffs turning counterclockwise
Replace
Wash out with hose. Pick lint out with a wire
Replace
Turn off power, drain recovery tank.
Pump runs no solution
Pump not primed
Internal or external solution line damaged and leaking
Pump runs, loss of pressure
Clean inlet screen
Press trigger to open valve on cleaning wand to relieve air lock.
Replace
Internal pump components wearing out Replace, see pump kit components
Pump will not run
Solution hose fitting hard to connect
Carpet not getting clean
Carpet too wet
Carpet browning
Solution not flowing properly
Faulty switch
Loose wiring
Corrosion on fittings.
Severe soil conditions
Over saturation
Leaving carpet too wet
Too much chemical
Solution hose connection
Faulty pump
Faulty floor tool valve / Nozzle
Faulty pump switch
Replace
Repair or replace
Clean with steel wool. Soak in acetic acid (white vinegar). Lubricate lightly with silicone base lubricant.
Make several passes at right angles to each other. Use a pre-spray.
Make several passes without spray
Check for loss of vac pressure
Check label for correct solution concentration
Check for positive connection
Repair or replace
Repair or replace
Repair
86330780 DOMINATOR 150 PSI 17
Notes:
18 86330780 DOMINATOR 150 PSI
PARTS
86330780 DOMINATOR 150 PSI
Control Panel
3
6
10
1
4
12
2
5
7
8
9
10
11
20 86330780 DOMINATOR 150 PSI
Control Panel
REF PART NO.
PRV NO.
QTY
7
8
5
6
3
4
1
2
86202230
86002370
86002450
86197390
86005700
86276820
86007140
86008900
9 86323520
10 86313020
11 86313030
12 86318320
390-09A
20035
22015
31021
57104
70740
72130
80845
-
-
-
-
DESCRIPTION
2 WASHER 9/16 S/S USS THICK
1 CLAMP, 7/16 DIA NYLON UL
1 COUPLER, 1/4 QD
1 ELBOW, 1/4NPT 45D STREET
2 NUT, 10-32 HEX W/ STAR
6 SCR, 10-32 X 1/2 PTHMS BLK NP
3 SWITCH, SPST 2-POSITION ROCKER
2 BOOT, SEAL PUSH BUTTON 7/16
1 PANEL, CONTROL, 150
2 GASKET, .125 T X .25 W X 15.6
4 GASKET, .125 T X .25 W X 7.2
2 BREAKER, 13A, 250VAC, 32VDC
SERIAL NO.
FROM
NOTES
86330780 DOMINATOR 150 PSI 21
Electrical
1
13
10
14
3
7
4
2
11
8
3
17
5
16
19
18
9
6
15
12
22 86330780 DOMINATOR 150 PSI
Electrical
REF PART NO.
PRV NO.
QTY
1 86201510
2 86005670
3 86005700
4 86273830
5 86006850
6 86256200
7 86255900
8 86010630
9 86316460
10 86316540
11 86316700
12 86318620
13 86319090
14 86319110
15 86317580
16 86005810
17 86323330
18 86198460
19 86006590
-
-
-
-
-
-
-
57245
390-26
57040
57104
70020
70393
73200
73538
87013
-
20008
70088
DESCRIPTION
2 SPACER NYLON 1/4ID X 1/2 OD
1 NUT, 1/2 NPT CONDUIT
3 NUT, 10-32 W/STAR WASHER PLTD
2 SCR, 1/4-20 X 1/2 HHCS SS
2 SET SCR, 1/4-20 X 1.25L
1 STRAIN RELEIF, 1/2 NPT FLEX
2 STANDOFF, 6-32 X 5/8 HEX NYL
2 WASHER, 1/4 X 5/8 FLAT SS
1 BRKT, ELECTRICAL
1 CONNECTOR, 5 POS, PUSH WIRE
1 BRKT, CORD STRAIN RELIEF
1 CORD ASM, 14/3 SJT X 25' BLK
1 FUSE HOLDER, PANEL MNT
1 FUSE, 1/4" X 1 1/4", 4A
1 BRKT, CORD, BLANK
2 NUT, 1/4-20 NYLOCK
2 WASHER, 1/4" ID X 1.0D FLAT BLK
1 CLAMP, 5/8 NYLON UL/CSA
1 SCREW 10-32 X 1/2 PPHMS SS NP
SERIAL NO.
FROM
NOTES
86330780 DOMINATOR 150 PSI 23
Frame
2
9
1
11
6
5
3
10
7
4
8
24 86330780 DOMINATOR 150 PSI
Frame
REF PART NO.
PRV NO.
QTY
7
8
5
6
3
4
1
2
86199430
86001660
86005810
86276080
86010630
86005700
86010730
86219480
9 86309790
10 86312830
11 86277500
040-03
41236
57245
70595
87013
57104
87088
41567
-
-
70853
DESCRIPTION
2 CASTER, SWIVEL 4" 250# CPCTY
2 HUBCAP, 5/8 SHAFT
8 NUT, 1/4-20 HEX NYLOCK SS
1 SCR, 10-32 X 1” PPHMS GRN
8 WASHER, 1/4 X 5/8 FLAT SS
2 NUT, 10-32 HEX W/STAR
4 WASHER, 5/8 X 1-3/16 FLAT SS
2 HUBCAP, 9.75" WHEEL
2 WHEEL, 12" X 2.25”
1 FRAME, 5/8" AXLE, DUAL VAC
8 SCR,1/4-20 X 5/8 CARR SS
SERIAL NO.
FROM
NOTES
86330780 DOMINATOR 150 PSI 25
Labels
3
2
1
26 86330780 DOMINATOR 150 PSI
REF PART NO.
PRV NO.
QTY
1 86321760
2 86321770
3 86330730
-
-
-
1
1
1
DESCRIPTION
LABEL, DOM, RH
LABEL, DOM, LH
LABEL, DOM, 150
Labels
SERIAL NO.
FROM
NOTES
86330780 DOMINATOR 150 PSI 27
Pump
3
1
13
11
6
12
TO SOLUTION FITTING
5
2
4
FROM SOLUTION TANK
7
10
9
28
11
8
86330780 DOMINATOR 150 PSI
Pump
REF PART NO.
PRV NO.
QTY
7
8
5
6
3
4
1
2
86197290
86233150
86197360
86282320
86197940
86005640
86005710
86274450
9 86233410
10 86010630
11 86010650
12 86317880
13 86318630
14076
20042
31016
39710
40027
57030
57105
70202
81270
87013
87018
-
-
DESCRIPTION
1 BUSHING, 3/8 MPT X 1/4 FPT HEX
1 CLAMP, 3/8 WORM GEAR
1 ELBOW, 1/4 NPT STREET
1 HOSE, 1/2ID WIRE BOUND X 26"
1 HOSEBARB, 3/8 MPT X 1/2 HOSE 90
4 NUT, 10-32 HEX NYLOCK
1 NUT, 1/4-20 HEX W/STAR WASHER
4 SCR, 10-32 X 1.25 HHMS PLTD
1 CLAMP, 3/4 DIA CUSHION .406 DIA
1 WASHER, 1/4 X 5/8 FLAT SS
8 WASHER, #10 X 9/16 FLAT
1 HOSE,49.0 GRY3/8 1/4MPTX1/4MPT
1 PUMP, 115V 150PSI BYPASS
SERIAL NO.
FROM
NOTES
86330780 DOMINATOR 150 PSI 29
Recovery
15
3
19
2
4
8
10
18
6
11
14
21
10
12
20
13
10
5
16
17
9
7
1
30 86330780 DOMINATOR 150 PSI
Recovery
REF PART NO.
PRV NO.
QTY DESCRIPTION
7
8
5
6
3
4
1
2
86161460 15-808123 1 DUMP VALVE, 1 1/2”
86002620 260-64A 1 ACCESS, COVER CLEAR 6" W/RIM
86197820
86004000
31002
35255
1
1
ELBOW, 1.5 FPT X FS PVC
GASKET, TANK LID
86197040
86273740
86273750
86275800
57264
70010
70011
70546
2
2
4
6
NUT, 5/16-18 HEX ACORN PLTD
SCR, 1/4-20 X 1.50 HHCS SS
SCR, 1/4-20 X 5/8 HHCS SS
SCR, 8 X 3/4 PFHT/S BLK ZINC
9 86010630
10 86010670
11 86323330
12 86011020
87013
87029
-
89202
13 86001350 140390
14 86311510 -
15 86324960
16 86313040
-
-
17 86316710
18 86317230
19 86317720
20 86320790
21 86233120
-
-
-
-
20019
4
6
2
2
2
1
1
1
2
1
2
1
1
WASHER, 1/4 X 5/8 FLAT SS
WASHER, 5/16 X 3/4 SS
WASHER, 1/4 ID X 1.0 OD FLAT BLK
WHEEL, 3" DIA. CUSHION RUBBER
BUSHING, SPANNER .435 X 1.10
ADAPTER, FLOAT 30 DEG, 2”
TANK, RECOVERY, TRIMMED
SCRN, FLOAT, SHTOFF, 2”
BRKT, CORD, MOUNT
HOSEBARB,1.5MPT X 1.5 W/FLNG
SCR, 5/16-18 X 2.50 BSHCS SS
PIPE ASM, 2", VACUUM
CLAMP, 2.75" WORM GEAR
SERIAL NO.
FROM
NOTES
86330780 DOMINATOR 150 PSI 31
Solution
19
14
8
3
18
16
9
17
1
4
23
13
6
2
6
5
13
12
22
7
10
11
20
15
1
21
32 86330780 DOMINATOR 150 PSI
Solution
REF PART NO.
PRV NO.
QTY DESCRIPTION
7
8
5
6
3
4
1
2
86173640 11-800437 1 ADPT,3/8 BLKHD
86233150 20042 1 CLAMP, 3/8 WORM GEAR
86238460
86197940
36259
40027
2
1
HOOK, STRAP
HOSEBARB, 3/8 MPT X 1/2 HOSE 90
86273740
86273830
86005810
86324210
70010
70020
57245
-
1
11
2
4
SCR, 1/4-20 X 1.50 HHCS SS
SCR, 1/4-20 X 1/2 HHCS SS
NUT, 1/4-20 HEX NYLOCK SS
SCR, 1/4-20 X 5/8 BHCS BLK
9 86276160
10 86007970
11 86233410
12 86010670
13 86010630
14 86323330
15 86311990
16 86312000
70604
73864
81270
87029
87013
-
-
-
2
1
2
2
12
2
1
1
SCR, 10-32 X 5/8 PPHMS BLK
STRAINER, 3/8 IN. NPT 60 MESH
CLAMP, 3/4 DIA CUSHION .406 DIA
WASHER, 5/16 X 3/4 SS
WASHER, 1/4 X 5/8 FLAT SS
WASHER, 1/4 ID X 1.0 OD FLAT BLK
HINGE, 9.5" LG X .074 THK
LID, SOLUTION, COVER
17 86312010
18 86330160
19 86297620
20 86317560
21 86318790
22 86242130
23 86324030
-
-
-
-
-
48100
-
1 LID, SOLUTION, HINGE BRKT
1 TANK, 17G SOL, 150 TRIM, BLU
2 STRAP, HAND TOOL
1 SPACER, .50 ODX .28 ID X 1.0L
1 WASHER, 1.032ID X 1.5OD X .062THK
2 KNOB, 1/4 HEX PRESS-LOC WING
2 PLATE, MOUNTING, SOLUTION
SERIAL NO.
FROM
NOTES
COMPLETE
86330780 DOMINATOR 150 PSI 33
Vacuum
1
4
12
5
9
13
11
2
7
6
10
3
34
4
8
86330780 DOMINATOR 150 PSI
Vacuum
REF PART NO.
PRV NO.
QTY
1 86005810
2 86274090
3 86233430
4 86010630
5 86278990
6 86311520
7 86312990
8 86314710
57245
70092
81431
87013
87017
-
-
-
9 86317630
10 86318300
-
-
11 86318760 -
86135320 140687
12 86312080
13 86312220
86319020
-
-
-
DESCRIPTION
8 NUT, 1/4-20 HEX NYLOCK SS
5 SCR, 10-32 X 1.5 PPHMS
2 CLAMP, 2.50 WORM GEAR
16 WASHER, 1/4 X 5/8 FLAT SS
8 WASHER, #8 X 3/8 FLAT
1 MANIFOLD, VACUUM, DUAL
1 GASKET, VAC MANIFOLD, DUAL
8 SCR, 1/4-20 X 5.50 HHCS PLT
8 SCR, #8 X 3/4" PPHSMS TYPE AB
1 HOSE, VAC, 2.0 ID X 18"L
2 VAC ASM, 2-STAGE, 120V
SP BRUSHES SET (120V VAC)
2 COVER, VAC MOTOR
2 BASE, VAC MOTOR, 2 STAGE
VAC HOUSING, 2 STAGE
SERIAL NO.
FROM
NOTES
INCLUDES 12, 13
86330780 DOMINATOR 150 PSI 35
Wiring Diagram
-VACUUM
SWITCH
-VACUUM
SWITCH
-PUMP
SWITCH
-POWER
CORD
BLK
-FUSE
4AMP
1
GRY-WHT
GRN
WHT
BLK
-CB
13AMP
-CB
13AMP
-TERMINAL
BLOCK
BLK-WHT
BLU/1 BLU-BLK/2 GRY/3
GRN
WHT
-VACUUM
MOTOR
GRN
WHT/7
-VACUUM
MOTOR
GRN
WHT/8
-PUMP
MOTOR
GRN
WHT
36 86330780 DOMINATOR 150 PSI
REF PART NO.
PRV NO.
QTY
1 98407900 1
DESCRIPTION
HARNESS KIT, SINGLE CORD
Wiring Diagram
SERIAL NO.
FROM
NOTES
86330780 DOMINATOR 150 PSI 37
Suggested Spare Parts
PART NO.
PRV NO.
DESCRIPTION
86135320 140687 BRUSH SET, 120V VAC
86199430 040-03 CASTER SWIVEL 4” 250# CAPACITY
86002620 260-64A ACCESS COVER CLEAR 6” W/RIM
86319110 FUSE, 1/4” X 1-1/4”, 4A
86318760
86007140
86309790
86001660
86007970
-
72130
-
41236
73864
VAC ASSY 2-STG, 120V
SWITCH, SPST 2-POSITION ROCKER
WHEEL, 12” X 2.25”
HUBCAP, 5/8” SHAFT
STRAINER 3/8” NPT 60 MESH
SERIAL NO.
FROM
NOTES
38 86330780 DOMINATOR 150 PSI
REF.
NO.
1 N/A
MODEL: SERIAL #
Serial Numbers
86330780 DOMINATOR 150 PSI 39
Notes:
40 86330780 DOMINATOR 150 PSI
Advertisement