3DYR56XX Series Fan Owner’s Guide and Installation Manual

3DYR56XX Series Fan Owner’s Guide and Installation Manual
Owner’s Guide and Installation Manual
3DYR56XX Series Fan
ETL Model NO. : 3DYR56XXXXX
Attach sales receipt to this card and retain as your proof of purchase
DATE OF PURCHASE:
RETAILER NAME:
MODEL NUMBER:
RETAILER ADDRESS:
To register your fixture, please visit our website www.montecarlofans.com
7.8 kgs
17.2 lbs
3064964
Total fan weight
Cautions and Warnings
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING
READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70-1999), including fire-rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.
WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.
WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of
15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.
WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do
not insert foreign object between rotating blades.
CAUTION: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the
building structure (or the ceiling joist).
Attach the mounting bracket using only the hardware supplied with the outlet box.
WARNING: To Reduce The Risk Of Electric Shock, This Fan Must Be Installed With a general use, isolating Wall Control/Switch.
WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. DC8 manufactured by
Carewell Electric Technology (Zhongshan) Co.,Ltd.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable
speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.
CAUTION: The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is
required, the product should be returned to an authorized service facility for examination or repair.
All set screws must be checked, and re-tightened where necessary, before installation.
Note: Suitable for use in wet locations when installed in a GFCI protected branch circuit.
Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers
Customer Service
800-969-3347
Customer Service Center
7400 Linder Ave.
Skokie, IL 60077
www.montecarlofans.com
© 2015 Monte Carlo Fan Company
2
9/15/2015
1
2
ON
3
ON
Mounting bracket
OFF
OFF
Before you begin installing the fan, Switch
power off at Service panel and lock
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a warning device, such
as a tag, to the service panel.
4
Downrod
Before installing this fan make sure the
outlet box is properly installed to the
house structure. To reduce the risk of
fire, electric shock, or personal injury,
mount to outlet box or supporting system
acceptable for fan support.
(Mounting must support at least 35 lbs.)
5
Lead wire
Safety cable
Use metal outlet box suitable for fan
support and use only the screws provided
with the outlet box (must support 35
lbs). Before attaching fan to outlet box,
ensure the outlet box is securely fastened
by at least two points to a structural
ceiling member (a loose box will cause
the fan to wobble). Remove the two outlet
box screws provided with the box,
aligning the holes of the mounting
bracket with the holes of the outlet box.
Reinstall the 2 outlet box screws
securely.
6
Downrod
Canopy
Yoke cover
Canopy
Downrod
Downrod
Yoke
Set screw
Yoke cover
Keeper pin
Cross pin
Keeper pin
Cross pin
Remove preassembled keeper pin and
cross pin from downrod.
Place downrod over canopy and yoke
cover
© 2015 Monte Carlo Fan Company
Thread lead wires and safety cable from
motor assembly through downrod.
3
Slip downrod into motor housing yoke,
aligning holes and install cross pin and keeper
pin.
Insert cross pin through yoke and downrod
until point appears on the other side, and
insert keeper pin on cross pin.
Pull the downrod up tight against the cross
pin, and then evenly tighten the downrod set
screws on motor housing yoke.
Place Yoke cover on motor assembly.
Warning: Cross pin and keeper pin must be
installed securely, failure to install them will
result in serious injury.
9/15/2015
7
8
Cable clamp
9
Tab
Rubber cover
Set screw
Slot
Downrod
Thread lead wires, grounding wire and
safety cable through watertight rubber
cover, then place the rubber cover onto
hanger ball on downrod. Rubber cover
provided.
Install cable clamp. Cable clamp
provided.
Slide cable clamp over the safety cable
and feed end of cable into clamp hole
and firmly tighten the set screw.
Install ball end of downrod into mounting
bracket opening. Align (engage) slot on
ball with tab on mounting bracket.
Warning: Failure to align slot on ball with
tab may result in serious injury.
Note: This fan is not available with
vaulted ceiling.
SAFETY CABLE INSTALLATION
10
11
Black (Live)
Wall Switch
Power source
White (Neutral)
Ground/Green
Red (Motor 1)
Purple (Motor 2)
Lag screw
Gray (Motor 3)
Safety cable
Green/Ground
Receiver
Washer
Lock washer
For Canadian installation and for USA fan
and light kit combinations over 35 lbs, in
both flush and downrod modes the safety
cable must be installed into the house
structure beams using 1.5” lag screws,
washers and lock washers provided.
Make sure that when the safety cable is
fully extended the lead wires are longer
than the cable and no stress is placed on
the lead wires.
Note: If Installing The Secondary Support
White (AC IN N)
Black (AC IN L)
Make wiring connections using wire connectors provided as indicated above.
Red from fan to Red from remote marked Motor 1.
Purple from fan to Purple from remote marked Motor 2.
Gray from fan to Gray from remote marked Motor 3.
White (Neutral) from house to White from remote marked AC IN N.
Black (Live) from house to Black from remote marked AC IN L.
Connect all green grounded wires to Grounded wire from House.
Make sure that no filaments are outside of the wire connectors.
Insert the remote receiver into mounting bracket.
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
© 2015 Monte Carlo Fan Company
4
9/15/2015
12
13
14
Mounting
bracket
Canopy
Blade bracket
Partially loosen 2 of the set screws on
mounting bracket corresponding to the
slotted holes on the canopy upper ring.
Remove the other 2 set screws. Save
screws.
Raise canopy to mounting bracket,
aligning loosened screws in mounting
bracket with slotted holes in canopy.
Twist canopy to lock. Reinstall the screws
removed in step 12 and tighten all
screws securely.
15
16
Install blade bracket onto motor with set
screws provided.
Repeat this process for remaining blade
brackets. Tighten all set screws securely
Alignment post
Decorative cap
Blade
Install a decorative cap onto motor shaft
by turning clockwise until tight.
© 2015 Monte Carlo Fan Company
Install blade, aligning 3 alignment posts
on blade with the holes in blade bracket,
then install it with set screws provided.
Repeat this process for remaining blades.
Tighten all screws securely.
5
9/15/2015
REMOTE CONTROL SETTING and OPERATION
Transmitter Operation
Remove the battery cover from the remote control transmitter and install
battery, battery provided. Replace the cover.
Note: Use 2 1.5V/AAA battery.
Note: If not using for long period of time, remove battery to prevent damage
to remote transmitter, and store the remote transmitter away from excess
heat or humidity.
Universal Mode and Learning Mode
There are “Universal Mode” and “Learning Mode” with the remote controller.
If choosing “Universal Mode”, simply place dip (code) switch at UPPER
position. Your fan with the remote controller is ready to use.
Note: If using universal mode, your fan can be controlled with other remote
transmitters with the same setting.
COMMON
CODE
COMMON
CODE
LEARN
Learn function setting, Restore power source to your fan, press and hold
the “LEARN” button for at least 3 seconds. You must press the “LEARN”
button within 60 seconds of restoring power to the fan.
Universal Mold
Learn
LEARN
To control the fan with specific remote transmitter, choose “Learning Mode”
by placing the dip (code) switch at LOWER position and then make learn
function setting as below.
L.CODE
Note: If the power is on already, you must turn the power off for 10 seconds
at least, and then turn the power back for remote control learn function
setting.
L.CODE
Learning Mold
Note: If the fan is installed with light, light will twinkle 2 times. The remote
control setting process is complete and your fan is ready for use. For fans
without light, check operation using remote transmitter.
Note: If you want to control the fan with another transmitter, make the same
setting. A fan can be controlled by 2 transmitters maximum.
The receiver provides the following protective functions
Lock protection- The DC motor has a build-in safety feature against blade or motor obstruction during operation. If
something obstructs the fan blades or motor, the motor will keep trying to run for 5 times and then stop operation
after about 60 seconds of interruption. Please remove obstacles and reset. To reset it by turn the fan off by remote
transmitter and then turn the fan on, Or you may turn power off for 15 seconds then turn power back, and then turn
the fan on,
Over load protection (current limit)- The device will limits the maximum current output from the receiver/drive when the
fan or light load was increased abnormally.
© 2015 Monte Carlo Fan Company
6
9/15/2015
The buttons on the remote control transmitter control the fan speed and light as follows.
Fan speed
1 = minimum speed
3 = medium low speed
5 = medium high speed
2 = low speed
4 = medium speed
6 = high speed
This button turns the fan off.
Forward/Reverse button- This button is to control direction of fan rotation. Press once
to change direction of the fan rotation. Fan must be running to reverse.
Note: This remote controller has auto resume function, the fan will maintain the last setting
if power is turned off.
Wall mount cradle installation
Install Transmitter wall mount cradle with 2 screws provided.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS
SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1)THIS DEVICE MAY NOT
CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Tips for end users
1. If your fan is operated automatically after installation and power on, it is because your fan is still memorize the previous
setting at factory.
2. If fan or light isn’t working, reset power (turn the power off for at least 10 seconds and then turn the power back) and redo
the learn function setting.
3. It is not available to separately operate the learn setting for more than one fan in the same room (in the area where remote
signal can reach to) if they share the same power supply. Separate power supplies (like as using individual wall switches for each
fan and turn power off for the fan while you are making learn function for other fan) is required if you want to separately control
more than one fan in same room.
4. When fan is turned on or operated forward/reverse function, it shutters & goes back & forth until it turns. It is a normal
performance of this fan and it will take for few seconds to run this operation.
© 2015 Monte Carlo Fan Company
7
9/15/2013
Trouble Shooting
,I\RXKDYHGLI¿FXOW\RSHUDWLQJ\RXUQHZFHLOLQJIDQLWPD\EHWKHUHVXOWRILQFRUUHFWDVVHPEO\LQVWDOODWLRQ
RUZLULQJ,QVRPHFDVHVWKHVHLQVWDOODWLRQHUURUVPD\EHPLVWDNHQIRUGHIHFWV,I\RXH[SHULHQFHDQ\IDXOWV
SOHDVHFKHFNWKLV7URXEOH6KRRWLQJ&KDUW,IDSUREOHPFDQQRWEHUHPHGLHGRU\RXDUHH[SHULHQFLQJGLI¿FXOW\LQ
LQVWDOODWLRQSOHDVHFDOORXU&XVWRPHU6HUYLFH&HQWHUDWWKH
QXPEHUSULQWHGRQ\RXUSDUWVOLVWLQVHUWVKHHW
Warning %HIRUH VHUYLFLQJ RU FOHDQLQJ XQLW 6ZLWFK SRZHU RII DW 6HUYLFH SDQHO DQG ORFN VHUYLFH GLVFRQQHFWLQJ
PHDQVWRSUHYHQWSRZHUIURPEHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFHGLVFRQQHFWLQJPHDQVFDQQRWEH
ORFNHGVHFXUHO\IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJWRWKHVHUYLFHSDQHO
Trouble
Suggested Remedy
,IIDQGRHVQRWVWDUW
&KHFNPDLQDQGEUDQFKFLUFXLWIXVHVRUFLUFXLWEUHDNHUV
&KHFNOLQHZLUHFRQQHFWLRQVWRIDQDQGVZLWFKZLUHFRQQHFWLRQVLQVZLWFKKRXVLQJ
CAUTION0DNHVXUHPDLQSRZHULVWXUQHGRII
,I WKLV IDQ XVHV PDQXDO IRUZDUGUHYHUVH VZLWFK PDNH VXUH WKH VZLWFK LV SXVKHG ¿UPO\
HLWKHUZD\)DQZLOOQRWRSHUDWHZKHQVZLWFKLVLQWKHPLGGOH
,IWKLVIDQXVHVUHPRWHFRQWUROOHUPDNHVXUHGLSVZLWFKHVDUHVHWWLQJSURSHUO\DQGPDNH
VXUHEDWWHU\LVHIIHFWLYH
,IIDQVRXQGVQRLV\
&KHFNWRPDNHVXUHDOOVFUHZVLQPRWRUKRXVLQJDUHVQXJQRWRYHUWLJKWHQHG
&KHFNWRPDNHVXUHWKHVFUHZVZKLFKDWWDFKWKHIDQEODGHKROGHUWRWKHPRWRUDUHWLJKW
&KHFNWRPDNHVXUHZLUHQXWFRQQHFWRUVLQVZLWFKKRXVLQJDUHQRWUDWWOLQJDJDLQVWHDFK
RWKHURUDJDLQVWWKHLQWHULRUZDOORIWKHVZLWFKKRXVLQJ
CAUTION0DNHVXUHPDLQSRZHULVWXUQHGRIIEHIRUHHQWHULQJVZLWFKKRXVLQJ
&KHFNWREHVXUHOLJKWEXOELVWLJKWLQVRFNHWDQGQRWWRXFKLQJWKHJODVVVKDGH
6RPHIDQPRWRUVDUHVHQVLWLYHWRVLJQDOVIURP6ROLG6WDWHYDULDEOHVSHHGFRQWUROV
$OORZEUHDNLQSHULRGRIKRXUV0RVWQRLVHVDVVRFLDWHGZLWKDQHZIDQZLOOGLVDSSHDU
DIWHUWKLVSHULRG
,IIDQZREEOHV
,I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH
QRWFKLQWKHGRZQURGEDOO
0DNH VXUH WKDW FDQRS\ PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO\ WR
FHLOLQJMXQFWLRQER[DQGMXQFWLRQER[LVPRXQWHG¿UPO\WRFHLOLQJMRLVW
&KHFNWKDWDOOEODGHVDUHVFUHZHG¿UPO\LQWREODGHKROGHUV
&KHFNWKDWDOOEODGHKROGHUVDUHWLJKWHQHGVHFXUHO\WRPRWRU
0RVWIDQZREEOHSUREOHPVDUHFDXVHGZKHQEODGHOHYHOVDUHXQHTXDO&KHFNWKLVOHYHOE\
VHOHFWLQJ D SRLQW RQ WKH FHLOLQJ DERYH WKH WLS RI RQH RI WKH EODGHV 0HDVXUH WKLV GLVWDQFH
IURPEODGHWLSWRFHLOQJ.HHSLQJPHDVXUHZLWKLQURWDWHWKHIDQXQWLOWKHQH[WEODGH
LV SRVLWLRQHG IRU PHDVXUHPHQW 5HSHDW IRU HDFK EODGH ,I DOO EODGH OHYHOV DUH QRW HTXDO
\RXFDQDGMXVWEODGHOHYHOVE\WKHIROORZLQJSURFHGXUH7RDGMXVWDEODGHWLSGRZQLQVHUW
D ZDVKHU QRW VXSSOLHG EHWZHHQ WKH EODGH DQG EODGH KROGHU DW WKH VFUHZ FORVHVW WR WKH
PRWRU7RDGMXVWDEODGHWLSXSLQVHUWZDVKHUQRWVXSSOLHGEHWZHHQWKHEODGHDQGEODGH
KROGHU DW WKH WZR VFUHZV IDUWKHVW IURP WKH PRWRU 5HYHUVH WKH SRVLWLRQ RI WKH ZDVKHU LI
EODGHVPRXQWIURPWRSRIEODGH
,IEODGH ZREEOH LV VWLOO QRWLFHDEOHLQWHUFKDQJLQJWZR DGMDFHQWVLGH E\VLGH EODGHVFDQ
UHGLVWULEXWHWKHZHLJKWDQGSRVVLEO\UHVXOWLQVPRRWKHURSHUDWLRQ
,IOLJKWGRHVQRWZRUN &KHFNEOXHZLUHIURPIDQWRPDNHVXUHLWLVFRQQHFWHGWRKRWZLUHIURPKRXVH
&KHFNIRUORRVHRUGLVFRQQHFWHGZLUHVLQIDQVZLWFKKRXVLQJ
&KHFNIRUORRVHRUGLVFRQQHFWHGZLUHVLQOLJKWNLW
&KHFNIRUIDXOW\OLJKWEXOEDQGPDNHVXUHEXOELVWLJKWLQVRFNHW
5HPRYHOLJKWNLWDQGFKHFNWKHSOXJFRQQHFWLRQVLIWKH\DUHSUHVHQW
,IWKLVIDQXVHVUHPRWHFRQWUROOHUPDNHVXUHGLSVZLWFKHVDUHVHWWLQJSURSHUO\DQGPDNH
VXUHEDWWHU\LVHIIHFWLYH
CAUTION 0DNH VXUH PDLQ SRZHU LV WXUQHG RII EHIRUH HQWHULQJ VZLWFK KRXVLQJ DQGRU
FDQRS\
© 2015 Monte Carlo Fan Company
8
9/15/2015
Sep.2015