Swing Piston Compressors and Vacuum Pumps NPK 25 AC NPK 25 DC Operating and Installation Instructions Read and observe these Operating and Installation Instructions! Contents KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Tel. +49-(0)7664-5909-0 Fax +49-(0)7664-5909-99 E-Mail: [email protected] www.knf.de 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Page About this document................................................................. 2 Use ........................................................................................... 3 Safety ....................................................................................... 4 Technical data .......................................................................... 6 Design and function .................................................................. 7 Installation and connection ....................................................... 8 Operation ................................................................................ 12 Servicing ................................................................................. 13 Troubleshooting ...................................................................... 16 Spare parts and accessories .................................................. 18 Returns ................................................................................... 19 Health and safety clearance and decontamination form ........ 20 KNF 121581-121584 10/14 Translation of original Operating and Installation Instructions, english Keep for future use! About this document Swing Piston Pumps NPK 25 1. About this document 1.1. Using the Operating and Installation Instructions The Operating and Installation Instructions are part of the pump. Pass on the Operating and Installation Instructions to the next owner. Project pumps Customer-specific project pumps (pump models which begin with "PJ" or "PM") may differ from the Operating and Installation Instructions. For project pumps, also observe the agreed upon specifications. 1.2. Symbols and markings Warning A danger warning is located here. Possible consequences of a failure to observe the warning are specified here. The signal word, e.g. WARNING Warning, indicates the danger level. Measures for avoiding the danger and its consequences are specified here. Danger levels Signal word Meaning warns of immediDANGER ate danger WARNING CAUTION Consequences if not observed Death or serious injuries and/or serious damage are the consequence. warns of possible Death or serious injuries danger and/or serious damage are possible. warns of a possibly Minor injuries or damage are dangerous situapossible. tion Tab. 1 Other information and symbols An activity to be carried out (a step) is specified here. 1. The first step of an activity to be carried out is specified here. Additional, consecutively numbered steps follow. This symbol refers to important information. 2 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Use 2. Use 2.1. Proper use The pumps are designed for pumping air. Owner's responsibility Operating parameters and conditions Requirements for transferred medium Only install and operate the pumps under the operating parameters and conditions described in Chapter 4, Technical data. Before using a medium, check whether the medium can be transferred danger-free in the specific application case. When using a medium other than air: Before using a medium, check the compatibility of the materials of the pump head, swing piston and piston seal with the medium. 2.2. Improper use The pumps may not be operated in an explosive atmosphere. The pumps may not be used to pump combustible or potentially explosive media. The pumps are not suitable for pumping vapors or liquids. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 3 Safety Swing Piston Pumps NPK 25 3. Safety Note the safety precautions in sections 6. Installation and connection, and 7. Operation. The pumps are built according to the generally recognized rules of technology and in accordance with the occupational safety and accident prevention regulations. Nevertheless, dangers can result during its use which lead to injuries to the user or others, or to damage to the pump or other property. Only use the pumps in proper technical condition and in accordance with its intended use in a safety and danger-conscious manner while observing the Operating and Installation Instructions. Personnel Make sure that only trained and instructed personnel or specially trained personnel work on the pump. This especially applies to assembly, connection and servicing work. Make sure that the personnel has read and understood the Operating and Installation Instructions, and in particular the "Safety" chapter. Working in a safetyconscious manner Handling dangerous media Observe the accident prevention and safety regulations when performing any work on the pump and during operation. When transferring dangerous media, observe the safety regulations when handling these media. Environmental protection Store all replacement parts in a protected manner and dispose of them properly in accordance with the applicable environmental protection regulations. Observe the respective national and international regulations. This especially applies to parts contaminated with toxic substances. EC Directives / Standards For the purposes of the Machinery Directive 2006/42/EC, pumps are “partly completed machinery,” and are therefore to be regarded as not ready for use. Partly completed machinery may not be commissioned until such time as it has been determined that the machine in which the partly completed machinery is to be assembled is in conformity with the provisions of the Machinery Directive 2006/42/EC. The following essential requirements of Annex I of Directive 2006/42/EC (general principles) are applied and observed: − − General Principles No. 1 No. 1.1.2. / 1.1.3. / 1.3.1. / 1.3.3. / 1.3.4. / 1.4.1. / 1.5.1.* / 1.5.2.* / 1.5.8. / 1.5.9. / 1.7.4. / 1.7.4.1. / 1.7.4.3. (* only for pump type NPK 25 AC) As these partly completed machinery are OEM-models the power supplies and the equipment for disconnecting and switching-off the partly completed machinery respectively have to be considered when mounting as well as over-current and overload protective gear. In addition a protection against mechanical parts in motion and hot parts, if existing, has to be provided when mounting. 4 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Safety The pumps conform to the Directive 2011/65/EU (RoHS2). The pumps conform to the EC Directive 2004/108/EC concerning Electromagnetic Compatibility. The following harmonized standards have been used: NPK 25 AC DIN EN 55014-1/2 DIN EN 61000-3-2/3 DIN EN 60335-1 NPK 25 DC DIN EN 55014-1/2 DIN EN 60034-1 Tab. 2 Customer service and repairs Only have repairs to the pump carried out by the KNF Customer Service responsible. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 5 Technical data Swing Piston Pumps NPK 25 4. Technical data Pump materials Assembly Head plate; cylinder Valve plate Piston seal O-ring Retainer plate Material Aluminium Stainless steel PTFE compound FPM Aluminium Tab. 3 Pneumatic values NPK 25 AC Parameter Max. permissible operating pressure [bar g] Ultimate vacuum [mbar abs.] Delivery rate at atm. pressure [l/min]* Tab. 4 Value 5 180 30 *Liters in standard state (1,013 mbar) NPK 25 DC Parameter Max. permissible operating pressure [bar g] Ultimate vacuum [mbar abs.] Delivery rate at atm. pressure [l/min]* Tab. 5 Value 4 180 25 *Liters in standard state (1,013 mbar) Electrical data Parameter Electrical data Protection class Value See type plate IP 20 Tab. 6 The AC motors used are fitted as standard with a thermal-switch to protect against overloading. Other parameters Parameter Permissible ambient temperature Values + 5 °C to + 40 °C Permissible media temperature Gas-tightness + 5 °C to + 40 °C The gas-tightness of the pump is dependent on the medium used.* * If you have questions about this, please contact your KNF advisor. Tab. 7 6 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Design and function 5. Design and function Design 1 2 3 4 5 6 Pneumatical outlet Pneumatical inlet Front fan cover Pump housing Base plate Motor Fig. 1: Swing piston compressor and vacuum pump NPK 25 AC Function 1 2 3 4 5 6 7 8 Inlet valve Outlet valve Transfer chamber Retainer plate Piston seal Eccentric Connecting rod Compressor housing Fig. 2: Function of swing piston pump The pumps transfer, compress and evacuate air. The swing piston, consisting of retainer plate (4) and piston seal (5), is moved up and down by the eccentric (6) and the connecting rod (7). In the downward stroke the swing piston aspirates the medium to be transferred via the inlet valve (1). In the upward stroke, the swing piston presses the medium out of the pump head via the outlet valve (2). The swing piston is sealed off from the compressor housing by a piston seal (5) and operates oil-free. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 7 Installation and connection Swing Piston Pumps NPK 25 6. Installation and connection Only install and operate the pump under the operating parameters and conditions described in Chapter 4, Technical data. Observe the safety precautions (see Chapter 3). 6.1. Installation Before installation, store the pump at the installation location to bring it up to room temperature. Mounting dimensions For the mounting dimensions see fig. 3 (NPK 25 AC) or fig. 4 (NPK 25 DC) Fig. 3: Mounting dimensions NPK 25 AC (All dimensions tolerances conform to DIN ISO 2768-1, Tolerance Class V) Fig. 4: Mounting dimensions NPK 25 DC (All dimensions tolerances conform to DIN ISO 2768-1, Tolerance Class V) 8 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Protection against touching Installation and connection For pumps with AC motors: Hazard of injuries during operation Take protective measures against touching parts connected to electrical power (electrical connection). WARNING Cooling air supply Installation location Install the pump so that the motor fan can intake sufficient cooling air. Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. Install the pump at the highest point in the system to prevent condensate from collecting in the pump head. Protect the pump from dust. Protect the pump from vibrations and jolts. 6.2. Electrical connection For pumps with AC motor: DANGER Extreme danger from electrical shock Only have the pump connected by an authorized specialist. Only have the pump connected when the power supply is disconnected. For pumps with DC motor: 2. Only have the pump connected by an authorized specialist. 3. Only have the pump connected when the power supply is disconnected. In the electrical installation, arrangements (complying with EN 60335-1) must be made for disconnecting the pump motor from the electrical supply. For pumps with AC motors KNF recommends that a fuse is installed in the motor supply circuit (overcurrent release). For operating current see type plate or data sheet. Connecting pump 1. Compare the supply data with the data on the motor-plate. The voltage must not vary by more than + 10% and - 10% from that shown on the type-plate. 2. NPK 25 AC Connect the mains cables to the connections L1 and N of the pump motor. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 9 Installation and connection Swing Piston Pumps NPK 25 NPK 25 DC Connect the positive and negative pole. With DC motors, note the proper polarity: red motor cable: + black motor cable: 3. Connect the earth (ground) wire to the motor (not necessary on dc motors up to 24 V). EMC-compatible Installation (for NPK 25 DC) The Tests: - Magnetic field with energy-technical frequency - Electromagnetic HF field, amplitude-modulated - Electromagnetic HF field, pulse-modulated - Discharging of static electricity - High frequency, asymmetric - Fast transients were not carried out, cause the products do not contain electronic modules, which can be affected by these tests. The Surge-test can only be passed with additional means, or is not mandatory, if: From EN61000-6-1 technical norm for EMC protection, part 1,10 test demands for EMC protection, table 3, EMC protection, D.C.- power in- and outputs. Remark 3: (quotation) Not to be used with input connections which are foreseen for a connection with a battery or a rechargeable battery which has to be removed or disconnected from the device for the recharge. Devices with a D.C. power input which are foreseen to be operated with an A.C. / D.C. converter have to be tested at an A.C. power input of an A.C. / D.C. converter fixed by the manufacturer. In case the converter was not fixed they have to be tested at an A.C. power input of a typical (usual) A.C. / D.C. converter. The test is applicable for D C power inputs which are foreseen for a permanent connection to cables which are longer than 10 m. 10 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Installation and connection 6.3. Pneumatic connection Connected components Pump exhaust Only connect components to the pump which are designed for the pneumatic data of the pump (see Chapter 4, Technical data). If the pump is used as a vacuum pump, safely discharge the pump exhaust. Connecting pump A marking on the pump head shows the direction of flow. 4. Remove the protective plugs from the hose connection threads. 5. The accessory silencer/filter (where applicable) is screwed into the port thread. If the pump is used as a vacuum pump, mount the silencer at the pressure side if necessary. If the pump is used a compressor, mount the filter at the suction side if necessary. 6. Connect the suction line and pressure line (threadsize G ¼``). 7. Lay the suction and pressure line at a downward angle to prevent condensate from running into the pump. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 11 Operation Swing Piston Pumps NPK 25 7. Operation Only operate the pumps under the operating parameters and conditions described in Chapter 4, Technical data. Make sure the pumps are used properly (see section 2.1). Make sure the pumps are not used improperly (see section 2.2). Observe the safety precautions (see Chapter 3). Hazard of the pump head bursting due to excessive pressure increase Do not exceed max. permissible operating pressure (see Chapter 4, Technical data). WARNING Only throttle or regulate the air quantity (the gas quantity) in the suction line to prevent the maximum permissible operating pressure from being exceeded. If the air quantity (the gas quantity) in the pressure line is throttled or regulated, make sure that the maximum permissible operating pressure is not exceeded. Monitor pressure during operation. If the pressure exceeds the maximum permissible operating pressure of the pump, immediately switch off pump and eliminate fault (see Chapter 9. Troubleshooting). Excessive pressure (with all of the related hazards) can be prevented by placing a bypass line with a pressure-relief valve between the pressure and suctions sides of the pump or by a pressure-relief valve. For further information, contact our technical adviser (see front page for telephone number). Pump standstill With the pump at a standstill, open pressure and suction lines to normal atmospheric pressure. Thermal switch For pumps with thermal switch: When the operation of the pump is interrupted by the thermal switch, the pump will restart automatically after cooling down. Take all necessary care to prevent this leading to a dangerous situation. Silencer/filter Switching pump on Change the silencer/filter (accessory) if it is dirty. The pump may not start up against pressure or vacuum during switch-on. This also applies in operation following a brief power failure. Make sure that normal atmospheric pressure is present in the lines during switch-on. 12 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Servicing 8. Servicing 8.1. Servicing schedule Component Pump Piston seal and valve plate Servicing interval Regular inspection for external damage or leaks - Replace at the latest, when pump output decreases Tab. 8 8.2. Cleaning Only use solvents for cleaning if the head materials cannot be attacked (check the resistance of the material). If compressed air is available, blow out the components. 8.3. Replacing piston seal and valve plate Conditions Information on procedure Spare parts Motor disconnected from mains and de-energized Pump free of dangerous substances Always replace the piston seal and valve plate together to maintain the pump performance. Spare part* Piston seal Valve plate Countersunk screw O-ring D 32 x 2.0 O-ring D 8.0 x 1.0 O-ring D 50 x 2.0 Position** (9) (4) (7) (3), (5) (8) (12) Quantity 1 1 1 4 1 1 * According to spare parts list, chapter 10 ** According to Fig. 5. Tab. 9 Tools and material Quantity 1 1 1 1 1 Tools/Material Phillips screwdriver No. 1 (only for pump NPK 25 DC) Phillips screwdriver No. 2 Screwdriver blade width 5.5 mm Allen key 4 mm Felt-tip pen Tab. 10 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 13 Servicing Swing Piston Pumps NPK 25 Prepatory step 1. Remove the front fan cover (Fig. 1/3, see page 6) of the pump after loosening the four fixing screws. Front fan is visible. Removing pump head 1. Mark the position of head plate (2), intermediate plate (6) and pump housing relatively to each other by a drawing line with a felt-tip pen to ensure proper assembly. 2. Unscrew the four screws (1) and remove the head plate (2). 3. Remove the valve plate (4) from the intermediate plate (6). 4. Remove the intermediate plate (6). 5. Remove O-rings (5) from intermediate plate (6). 6. Remove O-rings (3) from head plate (2). 7. Check the intermediate plate (6) and head plate (2) for soiling and damage. Clean the parts if necessary. 8. Contact KNF in case of roughness, scratches and corrosion. Order and replace damaged parts. 9. Move the retainer plate (9) to the upper point by turning the fan. Fig. 5: NPK 25 AC / NPK 25 DC: Parts of pump head 10. Pull cylinder (13) upwards. 11. Remove O-ring (12) from cylinder (13). 12. Hold on fan while loosening the countersunk screw (7) of retainer plate (9). 13. Remove countersunk screw (7), O-Ring (8), retainer plate (9) with piston seal (10). 14. Remove piston seal (10) from retainer plate (9). 15. Remove spacer(s) (11) from connecting rod (14). 16. Dispose of the old piston seal (10), valve plate (4), countersunk screw (7) and O-rings properly. Mounting pump head 1. Hold the connecting rod (14) from the front through the fan opening, and replace the cylinder (13) on the pump housing. 2. Lay new O-ring (12) on cylinder (13). 3. Re-assemble the “piston-assembly”: a. Lay the new piston seal (10) on the retainer plate (9). For orientation of piston seal (10) see fig. 6. Fig. 6: Orientation of piston seal (10) in relation to retainer plate (9) b. Fit new O-ring (8) onto new countersunk screw (7). c. Push the new countersunk screw (7) with new O-ring (8) through the retainer plate (9). 4. Fit the same number of washer(s) (11) as previously used on connecting rod (14). 14 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Servicing 5. Slide “piston assembly” (consisting of retainer plate (9), piston seal (10), and countersunk screw (7) with O-ring (8)) into the cylinder (13) from the top and place on connecting rod (14). The piston seal must not be distorted during assembly. It must make contact with the cylinder all round its circumference 6. Fasten the “piston assembly” by tightening the countersunk screw (7) (maximum tightening torque: 6.5 Nm). 7. Lay the two new O-rings (5) on intermediate plate (6). 8. Place the intermediate plate (6) on the pump housing in accordance with the felt-tip pen marking. 9. Place valve plate (4) on intermediate plate (6). To align the valve plate, refer to fig. 5 and a groove in the intermediate plate and valve plate: The two grooves must lie on top of each other. 10. Insert the two new O-rings (3) into the underside of head plate (2). 11. Place head plate (2) on intermediate plate (6). Head plate and intermediate plate have a notch each which must lay one upon the other. 12. Tighten the screws (1) at first lightly, then firmly by hand, in a diagonal pattern (max. tightening torque 6.5 Nm). Final step 1. Refit front fan cover. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 15 Troubleshooting Swing Piston Pumps NPK 25 9. Troubleshooting NPK 25 AC: Extreme danger from electrical shock! Disconnect the pump power supply before working on the pump. DANGER Make sure the pump is deenergized and secure. NPK 25 DC: Disconnect the pump power supply before working on the pump. Make sure the pump is deenergized and secure. All pumps: Check the pump (see Tab. 11 and 12). Pump does not transfer Cause Thermal switch has operated following to over-heating. Connections or lines blocked. External valve is closed or filter is clogged. Condensate has collected in pump head. Piston seal or valve plate is worn. Fault remedy Disconnect pump from mains. Allow pump to cool. Trace cause of over-heating and eliminate it. Check connections and lines. Remove blockage. Check external valves and filters. Install pump at highest point in system. Change piston seal and valve plate (see section 8.3). Tab. 11 The pump does not achieve the output (flow, pressure or vacuum) specified in the Technical data or the data sheet Cause Condensate has collected in pump head. There is gauge pressure on pressure side and at the same time vacuum or a pressure above atmospheric pressure on suction side. Pneumatic lines or connection parts have an insufficient cross section. Fault remedy Install pump at highest point in system. Change the pressure conditions. Disconnect pump from system to determine output values. Eliminate throttling (e.g. valve) if necessary. Use lines or connection parts with larger cross section if necessary. Eliminate leaks. Leaks occur on connections, lines or pump head. Connections or lines completely Check connections and lines. or partially jammed. Remove the jamming parts and particles. 16 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Troubleshooting The pump does not achieve the output (flow, pressure or vacuum) specified in the Technical data or the data sheet Cause Head parts are soiled. Fault remedy Clean head components. Piston seal or valve plate is worn. Change piston seal and valve plate (see section 8.3). Tab. 12 Fault cannot be rectified If you are unable to determine any of the specified causes, send the pump to KNF Customer Service (see last page for the address). 1. Flush the pump to free the pump head of dangerous gases. For this purpose, flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas). 2. Remove the pump. 3. Clean the pump (see Section 8.2) 4. Send the pump, together with completed Health and Safety Clearance and Decontamination Form (Chapter 12), to KNF stating the nature of the transferred medium. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 17 Spare parts and accessories Swing Piston Pumps NPK 25 10. Spare parts and accessories Spare parts Spare part Piston seal Valve plate Countersunk screw O-ring D 32 x 2.0 O-ring D 8.0 x 1.0 O-ring D 50 x 2.0 Tab. 13 Position* (10) (4) (7) (3), (5) (8) (12) Order No. 112635 113984 110712 116407 116408 006709 *according to Fig. 5 Accessories Accessory Silencer/filter Hose connector* Sealing for hose connector Tab. 14 18 Order No. 007007 000362 001818 * requires Sealing for hose connector Order No. 001818 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 Swing Piston Pumps NPK 25 Returns 11. Returns Pumps and systems used in laboratories and process-based industries are exposed to a wide variety of conditions. This means that the components contacting pumped media could become contaminated by toxic, radioactive, or otherwise hazardous substances. For this reason, customers who send any pumps or systems back to KNF must submit a Health and safety clearance and decontamination form in order to avoid a hazardous situation for KNF employees. This Health and safety clearance and decontamination form provides the following information, among other things: physiological safety whether medium-contacting parts have been cleaned whether the equipment has been decontaminated media that have been pumped or used and must declare physiological safety. To ensure worker safety, work may not be started on pumps or systems without a signed Health and safety clearance and decontamination form. For optimal processing of a return, a copy of this declaration should be sent in advance via e-mail, regular mail, or fax to KNF Customer Service (refer to final page for address). In order to avoid endangering employees who open the shipment's packaging, despite any residual hazards, the original version of the Health and safety clearance and decontamination form must accompany the delivery receipt on the outside of the packing. The template for the Health and safety clearance and decontamination form is included with these operating instructions and may also be downloaded from the KNF website. The customer must specify the device type(s) and serial number(s) in the Health and safety clearance and decontamination form in order to provide for the unambiguous assignment of the Declaration to the device that is sent to KNF. In addition to the customer's declaration of physiological safety, information about operating conditions and the customer's application are also of importance to ensure that the return shipment is handled appropriately. Therefore, the Health and safety clearance and decontamination form requests this information as well. Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 19 Health and safety clearance and decontamination form Swing Piston Pumps NPK 25 12. Health and safety clearance and decontamination form 20 Translation of original Operating and Installation Instructions, english, KNF 121581-121584 10/14 KNF worldwide Benelux Netherlands KNF Verder B.V. Utrechtseweg 4a NL-3451 GG Vleuten Tel. 0031 (0)30 677 92 40 Fax 0031 (0)30 677 92 47 E-mail: [email protected] www.knf-verder.nl Benelux Belgium, Luxembourg KNF Verder N.V. Kontichsesteenweg 17 B-2630 Aartselaar Tel. 0032 (0)3 8719624 Fax 0032 (0)3 8719628 E-mail: [email protected] www.knf.be China KNF Neuberger Trading (Shanghai) Co., Ltd No. 36 Lane 1000 Zhang Heng Road Shanghai 201203, P.R. China Tel. 0086 (0)21 685 965 66 Fax 0086 (0)21 339 006 26 E-mail: [email protected] www.knf.com.cn Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Tel. 0049 (0)7664 5909-0 Fax 0049 (0)7664 5909-99 E-mail: [email protected] www.knf.de France, Morocco, Algeria KNF Neuberger SAS 4, Bld. d’Alsace Z.I. F-68128 Village-Neuf Tel. 0033 (0)389 70 35 00 Fax 0033 (0)389 69 92 52 E-mail: [email protected] www.knf.fr Great Britain KNF Neuberger U.K. Ltd. Avenue 2 Station Lane Industrial Estate Witney Oxon OX28 4FA Tel. 0044 (0)1993 77 83 73 Fax 0044 (0)1993 77 51 48 E-mail: [email protected] www.knf.co.uk Sweden, Denmark, Finland, Norway KNF Neuberger AB Mejerivägen 4, P.O. Box 44060 SE-10073 Stockholm Tel. 0046 (0) 87445113 Fax 0046 (0) 87445117 E-mail: [email protected] www.knf.se India KNF Pumps + Systems (India) Pvt. Ltd. RAJIV GANDHI INFOTECH PARK Phase 1 Ganga Estate, Survey No. 152/2/2 Above AXIS BANK Hinjewadi Pune 411 057 Tel. 0091 (0)20 640 13 923 0091 (0)20 640 08 923 Fax 0091 (0)20 229 33 923 E-mail: [email protected] www.knfpumps.in Switzerland Sales KNF Neuberger AG Stockenstrasse 6 CH-8362 Balterswil Tel. 0041 (0)71 973 993 0 Fax 0041 (0)71 973 993 1 E-mail: [email protected] www.knf.ch Italy KNF ITALIA S.r.l. Via Flumendosa, 10 I-20132 Milano Tel. 0039 02 27 20 38 60 Fax 0039 02 27 20 38 48 E-mail: [email protected] www.knf.it Japan KNF Japan Co.Ltd. Across Shinkawa Bldg. Annex 3F 1-16-14 Shinkawa, Chuo-ku, Tokyo, Japan 104-0033 Tel. 0081 (0)3 3551-7931 Fax 0081 (0)3 3551-7932 E-mail: [email protected] www.knf.co.jp Taiwan KNF Neuberger Ltd. 9-2 FL., No., 24, Lane 123, Section 6, Ming Chuan East Road Taipei City, Taiwan Tel. 00886-2-2794-1011 Fax 00886-2-8792-1648 E-mail: [email protected] www.knftwn.com.tw USA, Canada, Latin America KNF Neuberger, Inc. Two Black Forest Road Trenton, New Jersey 08691-1810 Tel. 001 (609) 890-8600 Fax 001 (609) 890-8323 E-mail: [email protected] www.knfusa.com Latin America Direct phone: 001 609-649-1010 E-mail: [email protected] Korea KNF Neuberger Ltd. Woosan Bldg.RM#202, 336-4, Hwikyung-Dong Dongdaemun-Ku., 130-090, Seoul Tel. 0082 (0)2 959-0255/6 Fax 0082 (0)2 959-0254 E-mail: [email protected] www.knfkorea.com KNF product centres Product centre for gas pumps: Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Phone 0049(0)7664 5909-0 Fax 0049(0)7664 5909-99 E-mail: [email protected] www.knf.de Product centre for fluid pumps: Switzerland KNF FLODOS AG Wassermatte 2 CH-6210 Sursee Phone 0041(0)41 925 00 25 Fax 0041(0)41 925 00 35 E-mail: [email protected] www.knf-flodos.ch Product centre for micro pumps: Switzerland KNF Micro AG Zelglimatte 1b CH-6260 Reiden Tel. 0041(0)62 787 88 88 Fax 0041(0)62 787 88 99 E-mail: [email protected] www.knf-micro.ch
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement