Diaphragm Vacuum Pumps N 916.50 KPE Operating and Installation Instructions Read and observe these Operating and Installation Instructions! Contents KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone +49-(0)7664 / 5909-0 Fax +49-(0)7664 / 5909-99 E-Mail: [email protected] www.knf.de 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Page About this document................................................................. 2 Use ........................................................................................... 3 Safety ....................................................................................... 4 Technical Data ......................................................................... 6 Design and Function ................................................................ 7 Installation and connection ....................................................... 8 Operation ................................................................................ 12 Servicing ................................................................................. 14 Troubleshooting ...................................................................... 18 Spare parts and accessories .................................................. 20 Decontamination declaration .................................................. 21 KNF 123287-123290 05/13 Translation of original Operating and Installation Instructions, english Keep for future use! About this document Diaphragm Vacuum Pumps N 916.50 KPE 1. About this document 1.1. Using the Operating and Installation Instructions The Operating and Installation Instructions are part of the pump. Pass on the Operating and Installation Instructions to the next owner. Project pumps Customer-specific project pumps (pump models which begin with "PJ" or "PM") may differ from the Operating and Installation Instructions. For project pumps, also observe the agreed upon specifications. 1.2. Symbols and markings Warning A danger warning is located here. Possible consequences of a failure to observe the warning are specified here. The signal word, e.g. WARNING Warning, indicates the danger level. Measures for avoiding the danger and its consequences are specified here. Danger levels Signal word Meaning warns of immediDANGER ate danger WARNING CAUTION Consequences if not observed Death or serious injuries and/or serious damage are the consequence. warns of possible Death or serious injuries danger and/or serious damage are possible. warns of a possibly Minor injuries or damage are dangerous situapossible. tion Tab. 1 Other information and symbols An activity to be carried out (a step) is specified here. 1. The first step of an activity to be carried out is specified here. Additional, consecutively numbered steps follow. This symbol refers to important information. 2 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE 2. Use Use 2.1. Proper use The pumps are exclusively intended for transferring gases and vapors. Owner's responsibility Operating parameters and conditions Only install and operate the pumps under the operating parameters and conditions described in chapter 4, Technical data. Only complete pumps may be taken into service. Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. Requirements for transferred medium Before using a medium, check whether the medium can be transferred danger-free in the specific application case. Before using a medium, check the compatibility of the materials of the pump head, diaphragm and valves with the medium. Only transfer gases which remain stable under the pressures and temperatures occurring in the pump. 2.2. Improper use The pumps may not be operated in an explosive atmosphere. The pumps are not suitable for transferring dusts. The pumps are not suitable for transferring liquids. The pumps are not suitable for aggressive media. For aggressive media there are other pumps in the KNF product program – please ask us for detail. The pumps must not be used to create vacuum and overpressure simultaneously. An overpressure must not be applied to the suction side of the pump. Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 3 Safety Diaphragm Vacuum Pumps N 916.50 KPE 3. Safety Note the safety precautions in chapters 6. Installation and connection, and 7. Operation. The pumps are built according to the generally recognized rules of technology and in accordance with the occupational safety and accident prevention regulations. Nevertheless, dangers can result during their use which lead to injuries to the user or others, or to damage to the pump or other property. Only use the pumps when they are in a good technical and proper working order, in accordance with their intended use, observing the safety advice within the Operating and Installation Instructions, at all times. Personnel Make sure that only trained and instructed personnel or specially trained personnel work on the pumps. This especially applies to assembly, connection and servicing work. Make sure that the personnel has read and understood the Operating and Installation Instructions, and in particular the "Safety" chapter. Working in a safetyconscious manner Handling dangerous media Handling combustible media Observe the accident prevention and safety regulations when performing any work on the pump and during operation. When transferring dangerous media, observe the safety regulations when handling these media. Be aware that the pumps are not designed to be explosion-proof. Make sure the temperature of the medium is always sufficiently below the ignition temperature of the medium, to avoid ignition or explosion. This also applies for unusual operational situations. Note that the temperature of the medium increases when the pump compresses the medium. Hence, make sure the temperature of the medium is sufficiently below the ignition temperature of the medium, even when it is compressed to the maximum permissible operating pressure of the pump. The maximum permissible operating pressure of the pump is stated in the technical specifications (chapter 4). If necessary, consider any external sources of energy, such as radiation, that may add heat to the medium. In case of doubt, consult the KNF customer service. 4 Environmental protection Store all replacement parts in a protected manner and dispose of them properly in accordance with the applicable environmental protection regulations. Observe the respective national and international regulations. This especially applies to parts contaminated with toxic substances. EC Directives / Standards For the purposes of the Machinery Directive 2006/42/EC, pumps are “partly completed machinery,” and are therefore to be regarded as not ready for use. Partly completed machinery may not be commissioned until such time as it has been determined that the machine in which the partly completed machinery is to be assembled is in conformity with the provisions of the Machinery Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Safety Directive 2006/42/EC. The following essential requirements of Annex I of Directive 2006/42/EC (general principles) are applied and observed: − − General Principles No. 1 No. 1.1.2. / 1.1.3. / 1.3.1. / 1.3.3. / 1.3.4. / 1.4.1. / 1.5.1. / 1.5.2. / 1.5.8. / 1.5.9. / 1.7.4. / 1.7.4.1. / 1.7.4.3. As these partly completed machinery are OEM-models the power supplies and the equipment for disconnecting and switching-off the partly completed machinery respectively have to be considered when mounting as well as over-current and overload protective gear. In addition a protection against mechanical parts in motion and hot parts, if existing, has to be provided when mounting. The pumps conform to the Directive 2011/65/EU (RoHS2). The pumps conform to the EC Directive 2004/108/EC concerning Electromagnetic Compatibility. The following harmonized standards have been used: Customer service and repairs DIN EN 55014-1/2 DIN EN 61000-3-2/3 DIN EN 60335-1 Only have repairs to the pumps carried out by the KNF Customer Service responsible. Use only genuine parts from KNF for servicing work. Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 5 Technical Data Diaphragm Vacuum Pumps N 916.50 KPE 4. Technical Data Pump materials Assembly Pump head Diaphragm Valve plates O-rings Tab. 2 Material* PPS EPDM EPDM FPM *according to DIN ISO 1629 and 1043.1 Pneumatic performance Parameter Max. permissible operating pressure [bar g] Ultimate vacuum [mbar abs.] Delivery rate at atm. pressure [l/min]* Tab. 3 Value 0,5 20 16 * Liters in standard state (1013 mbar) Electrical data Parameter Electrical data Protection class Value see type label IP00 Tab. 4 Thermal-switch The pumps are fitted as standard with a thermal-switch to protect against overloading. Other parameters Parameter Permissible ambient temperature Value + 5 °C to + 40 °C Permissible media temperature + 5 °C to + 40 °C Dimensions:L x H x W [mm] approx. 205 x 133 x 114,5 Pneumatic connections Thread size G 1/8 Weight [kg] approx. 3.0 Maximum permissible ambient relative humidity 80 % for temperatures up to 31 °C, decreasing linearly to 50 % at 40 °C Max. altitude of site [m above sea level] 2000 Tab. 5 6 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE 5. Design and Function Design and Function Design 1 2 3 4 5 6 Fan Pneumatic pump inlet Motor Pneumatic head connection Pneumatic pump outlet Capacitor (electrical connected, not assembled) Fig. 1: Diaphragm Vacuum Pump N 916.50 KPE How diaphragm pumps work 1 2 3 4 5 6 7 Outlet valve Inlet valve Working chamber Diaphragm Eccentric Connecting rod Pump drive Fig. 3: Pump head Diaphragm pumps transfer, compress (depending on pump version) and evacuate gases and vapors. The elastic diaphragm (4) is moved up and down by the eccentric (5) and the connecting rod (6). In the downward stroke it aspirates the gas to be transferred via the inlet valve (2). In the upward stroke, the diaphragm presses the medium out of the pump head via the outlet valve (1). The diaphragm hermetically seals the working chamber (3) from the pump drive (7). Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 7 Installation and connection Diaphragm Vacuum Pumps N 916.50 KPE 6. Installation and connection Only install and operate the pumps under the operating parameters and conditions described in chapter 4, Technical data. Observe the safety precautions (see chapter 3). 6.1. Installation of the pump Before installation, store the pump at the installation location to bring it up to ambient temperature. Mounting dimensions Immediate environment Installation position Cooling air supply Attach connection cables Installation location For the mounting dimensions see Fig. 3, p. 9. When installing the pump, ensure that no flammable objects or objects subject to thermal deformation are located in the immediate vicinity of hot pump parts (head, motor). The pump may be installed in any position. Use metal screws to fasten the pump at the indicated attachment points. Install the pump so that the motor fan can intake sufficient cooling air. Fasten the connection cables so that: the cables do not contact moving parts the cables will not chafe or be damaged on sharp edges or corners no pulling or pushing forces are exerted on the cable’s connection points (strain relief) Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. The IP protection class of the pump motor is indicated on the type plate. Install the pump at the highest point in the system to prevent condensate from collecting in the pump head. Protect the pump from dust. Protect the pump from exposure to fats and oils. Protect the pump from vibrations and jolts. 8 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Protection against touching and foreign objects Installation and connection Hazard of injuries during operation Take protective measures against touching parts connected to electrical power (electrical connection, possibly motor coils). WARNING Take protective measures against touching moving parts (e.g. fans). The pump will restart automatically after the automatic resetting temperature limiter has been triggered. Hazard of damage to the pump during operation Take protective measures against foreign objects which could enter the pump. Fig. 3: Mounting dimensions pump N 916.50 KPE (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V) Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 9 Installation and connection Diaphragm Vacuum Pumps N 916.50 KPE 6.2. Electrical connection Extreme danger from electrical shock Only have the pump connected by an authorized specialist. DANGER Only have the pump connected when the power supply is disconnected. When connecting the device to a power source, the relevant standards, directives, regulations, and technical standards must be observed. In the electrical installation, arrangements (complying with EN 60335-1) must be made for disconnecting the pump motor from the electrical supply. KNF recommends that a fuse is installed in the motor supply circuit (overcurrent release). It is recommended that an additional “Emergency Stop” switch is installed. The pump must be installed so that contact with live parts is impossible. Connecting pump 1. Compare the supply data with the data on the motor-plate. For operating current see type plate. The voltage must not vary by more than + 10% and - 10% from that shown on the type-plate. 2. Connect the earth (ground) wire to the motor. 3. Connect motor cables: The pump N 916.50 KPE is connected electrically by means of a terminal strip. 10 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Installation and connection 6.3. Pneumatic connection Connected components Pump exhaust Only connect components to the pump which are designed for the pneumatic data of the pump (see chapter 4, Technical data). If the pump is used as a vacuum pump, safely discharge the pump exhaust at the pump’s pneumatic outlet. Connecting pump A marking on the pump head shows the direction of flow. 1. Remove the protective plugs from the hose connection threads. 2. Connect the suction line and pressure line (thread size G 1/8). Possible condensate is drained off through the pressure line; for that reason a tank to catch the condensate must be installed in the pressure line. Lay the suction and pressure line at a downward angle to prevent condensate from running into the pump. Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 11 Operation Diaphragm Vacuum Pumps N 916.50 KPE 7. Operation Only operate the pumps under the operating parameters and conditions described in chapter 4, Technical data. Make sure the pumps are used properly (see chapter 2.1). Make sure the pumps are not used improperly (see chapter 2.2). Observe the safety precautions (see chapter 3). The pumps are intended for installation. Before putting them into service it must be established that machinery or equipment in which they are installed meets the relevant regulations. Hazard of the pump head bursting due to excessive pressure increase Do not exceed max. permissible operating pressure (see chapter 4, Technical data). WARNING Monitor pressure during operation. If the pressure exceeds the maximum permissible operating pressure, immediately switch off pump and eliminate fault (see chapter 9. Troubleshooting). Only throttle or regulate the air or gas quantity in the suction line to prevent the maximum permissible operating pressure from being exceeded. If the air or gas quantity in the pressure line is throttled or regulated, make sure that the maximum permissible operating pressure is not exceeded. Ensure that the pump outlet is not closed or constricted. Excessive pressure (with all of the related hazards) can be prevented by placing a bypass line with a pressure-relief valve between the pressure and suctions sides of the pump. For further information, contact our technical adviser (see last page for telephone number). Pump standstill With the pump at a standstill, open pressure and suction lines to normal atmospheric pressure. Automatic starting can cause personal injury and pump damage When the operation of the pump is interrupted by the WARNING thermal switch, the pump will restart automatically after cooling down. Take all necessary care to prevent this leading to a dangerous situation. 12 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Operation Switching pump on The pump may not start up against pressure or vacuum during switch-on. This also applies in operation following a brief power failure. If a pump starts against pressure or vacuum, it may block. This activates the thermal switch, and the pump switches off. Make sure that no pressure or vacuum is present in the lines during switch-on. Switching pump off KNF recommends that, at the end of an evacuation operation, the pump should be allowed to run for a few minutes with the medium air (or, if necessary for safety reasons, with an inert gas) to remove condensate from the pump heads (drying of the pump). Open pressure and suction lines to normal atmospheric pressure. Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 13 Servicing Diaphragm Vacuum Pumps N 916.50 KPE 8. Servicing 8.1. Servicing schedule Component Pump Servicing interval - Regular inspection for external damage or leaks Tube connection - Diaphragm and valve plates - Regular inspection for external damage or leaks Replace if pump's pressure or flow rate change without apparent reason Replace at the latest, when pump output decreases Tab. 6 8.2. Cleaning When cleaning, make sure that no liquids enter the inside of the housing. 8.2.1. Flushing pump Flush the pump under atmospheric conditions some minutes with air (or, if necessary for safety reasons, with an inert gas) prior to switch-off. 8.2.2. Cleaning pump Conditions Motor disconnected from mains and de-energized Health hazard due to dangerous substances in the pump! Depending on the substance transferred, caustic WARNING burns or poisoning are possible. Wear protective clothing if necessary, e.g. protective gloves. Clean pump with suitable measures. Danger of burns from hot pump parts The pump head or motor may be hot even after the pump has been shut off. CAUTION Allow the pump to cool off after operation. As far as possible, clean the parts with a dry cloth. Solvents should not be used as they can attack the plastics, and synthetic rubber parts. If compressed air is available, blow out the components. 14 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Servicing 8.3. Replacing diaphragm and valve plates Conditions Motor disconnected from mains and de-energized Pump is clean and free of dangerous substances Tubes/pipes removed from pump’s pneumatic inlet and outlet Danger of burns from hot pump parts The pump head or motor may be hot even after the pump has been shut off. CAUTION Allow the pump to cool off after operation. Always replace diaphragm and the valve plates together to maintain the performance and safety of the pump. Health hazard due to dangerous substances in the pump! Depending on the substance transferred, caustic WARNING burns or poisoning are possible. Wear protective clothing if necessary, e.g. protective gloves. Clean pump with suitable measures. 8.3.1. N 816.3 KPE Spare parts Spare part* Diaphragm Valve plate O-rings Tab. 7 Tools and material Qty. 1 1 1 Tab. 8 Position** (8) (2) (3) Quantity 2 6 6 * according to Spare parts list, chapter 10 ** according to Fig. 5 Tools/material Phillips screwdriver No. 2 small slotted screwdriver Felt-tip pen * according to accessories list, chapter 10 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 15 Servicing Diaphragm Vacuum Pumps N 916.50 KPE Remove pump head 1. At both pump heads: Mark the position of head plate (Fig. 4/4), intermediate plate (1) and pump housing (11) relative to each other by a drawing line (M)with a felt-tip pen. This helps avoid incorrect assembly later. 2. At both pump heads: Undo the four screws (5) in the head plate. Fig. 4: Pump N 916.50 KPE 3. Remove both pump heads (each consisting of a head plate (4) and intermediate plate (1)) together from the pump housing (11). The connecting tubes should remain in place. Change diaphragm 1. Turn the fan (Fig. 4/10) to bring one diaphragm (Fig. 5/8) to top dead centre. 2. Lift the edge of the diaphragm (Fig. 5/8) and, gripping it on opposite sides, unscrew it by turning anti-clockwise. 3. Take the diaphragm spacers (9) off the threaded portion of the diaphragm and retain them. 4. Check that all parts are free from dirt and clean them if necessary (see chapter 8.2.2). 5. Put the diaphragm spacers (9) on the thread of the new diaphragm. 6. Turn the fan (Fig. 4/10) until the connecting rod (connecting part between motor shaft and diaphragm) is at top dead centre. Fig. 5: Pump head (exploded drawing, symbolic) 7. Screw the new diaphragm (Fig. 5/8), complete with diaphragm spacers (9), into the connecting rod (clockwise) and tighten it by hand. 8. Carry out steps 1 to 7 for the second pump head. Change valve plates 1. Separate the head plate (4) from the intermediate plate (1). 2. Remove the valve plates (2) and the O-rings (3) from the intermediate plate (1). 3. Check that the valve seats in the head plate and intermediate plate are clean; if scratches or distortion are evident on these parts they should be replaced. 4. Lay in valve plates: The valve plates are identical for all valves, as are upper and lower sides of the valve plates. Lay the new valve plates/sealings (2) in the recesses in the intermediate plate (1). 5. Lay the new O-rings (3) in the intermediate plate (1). 6. Place the head plate (4) on the intermediate plate (1), in the position indicated by the marking (Fig. 4/M). 16 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Servicing 7. Check that the head plate (Fig. 5/4) is centered by moving it gently sideways. 8. Carry out steps 1 to 7 for the second pump head. 9. Dispose of the old diaphragm and valve plates properly. Refit pump heads 1. Place the two pump heads that are joined by the connecting tube (7) on the housing according to the markings (Fig. 4/M). 2. On both pump heads: Gently tighten the screws (Fig. 5/5) , evenly and diagonally. 3. Turn the fan (Fig. 4/10) to check that the pump rotates freely. 4. Now tighten at both pump heads screws (Fig. 5/5) diagonally hand-tight. Final steps 1. Reconnect suction and pressure line to the pump. 2. Reconnect the pump to the electricity supply. If you have any questions about servicing call out technical adviser (see last page for contact telephone number). Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 17 Troubleshooting Diaphragm Vacuum Pumps N 916.50 KPE 9. Troubleshooting Extreme danger from electrical shock! Disconnect the pump power supply before working on the pump. DANGER Make sure the pump is de-energized and secure. Check the pump (see Tab. 9 and 10) Pump does not transfer Cause Thermal switch has operated following to over-heating. Connections or lines blocked. External valve is closed or filter is clogged. Condensate has collected in pump head. Diaphragm or valve plates are worn Fault remedy Disconnect pump from mains. Allow pump to cool. Trace cause of over-heating and eliminate it. Check connections and lines. Remove blockage. Check external valves and filters. Detach the condensate source from the pump. Flush pump (see chapter 8.2.1). Install the pump at the highest point in the system Replace diaphragm and valve plates (see chapter 8.3). Tab. 9 Flow rate, pressure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet. Cause Fault remedy Condensate has collected in Detach the condensate source from the pump. pump head. Flush pump (see chapter 8.2.1). Install the pump at the highest point in the system There is gauge pressure on The pump is not designed for this condition. pressure side and at the same time vacuum or a pressure above atmospheric pressure on suction side. The cross section of pneumatic To measure the performance, disconnect the pump from the lines, or connected components system (small diameter tubing or valve can significantly affect is too small, or they are restrictperformance). ed. Eliminate throttling (e.g. valve) if necessary. Use lines or connection parts with larger cross section if necessary. Leaks occur on connections, Eliminate leaks. lines or pump head. Connections or lines completely Check connections and lines. or partially jammed. Remove the jamming parts and particles. Head parts are soiled. Clean head components. Diaphragm or valve plates are worn Replace diaphragm and valve plates (see chapter 8.3). Tab. 10 18 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Troubleshooting Fault cannot be rectified If you are unable to determine any of the specified causes, send the pump to KNF Customer Service (see last page for the address). 1. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas) to free the pump head of dangerous or aggressive gases (see chapter 8.2.1). 2. Remove the pump. 3. Clean the pump (see chapter 8.2.2). 4. Send the pump to KNF with a filled out decontamination declaration (see chapter 11) and specification of the medium transferred. Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 19 Spare parts and accessories Diaphragm Vacuum Pumps N 916.50 KPE 10. Spare parts and accessories Spare parts Spare part Valve plates Diaphragm O-ring Tab. 11 20 Position* (2) (8) (3) Order No. 122814 121718 001926 *according to Fig. 5 Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 Diaphragm Vacuum Pumps N 916.50 KPE Decontamination declaration 11. Decontamination declaration The condition for the repair of a pump by KNF is the certification of the customer on the transferred media and on the cleaning of the pump (decontamination declaration). Copy this page. Enter the pump model, the Serial No. and the transferred media in the form below and sent the signed form together with the flushed and cleaned pump to KNF Customer Service (see last page for the address). Customer decontamination declaration for repair order We herewith confirm that the following media have been pumped with the pump listed below, and that the pump has been flushed and cleaned. Pump model Serial No. Fed media The pump contains neither aggressive, biological, radioactive, poisonous nor other dangerous media. Company Date/Signature Translation of original Operating and Installation Instructions, english, KNF 123287-123290 05/13 21 KNF worldwide Benelux Netherlands KNF Verder B.V. Utrechtseweg 4a NL-3451 GG Vleuten Tel. 0031 (0)30 677 92 40 Fax 0031 (0)30 677 92 47 E-mail: [email protected] www.knf-verder.nl Benelux Belgium, Luxembourg KNF Verder N.V. Kontichsesteenweg 17 B-2630 Aartselaar Tel. 0032 (0)3 8719624 Fax 0032 (0)3 8719628 E-mail: [email protected] www.knf.be China KNF Neuberger Trading (Shanghai) Co., Ltd No. 36 Lane 1000 Zhang Heng Road Shanghai 201203, P.R. China Tel. 0086 (0)21 685 965 66 Fax 0086 (0)21 339 006 26 E-mail: [email protected] www.knf.com.cn Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Tel. 0049 (0)7664 5909-0 Fax 0049 (0)7664 5909-99 E-mail: [email protected] www.knf.de France, Morocco, Algeria KNF Neuberger 4, Bld. d’Alsace Z.I. F-68128 Village-Neuf Tel. 0033 (0)389 70 35 00 Fax 0033 (0)389 69 92 52 E-mail: [email protected] www.knf.fr Great Britain KNF Neuberger U.K. Ltd. Avenue 2 Station Lane Industrial Estate Witney Oxon OX28 4FA Tel. 0044 (0)1993 77 83 73 Fax 0044 (0)1993 77 51 48 E-mail: [email protected] www.knf.co.uk Sweden, Denmark, Finland, Norway KNF Neuberger AB Mejerivägen 4, P.O. Box 44060 SE-10073 Stockholm Tel. 0046 (0) 87445113 Fax 0046 (0) 87445117 E-mail: [email protected] www.knf.se India KNF Pumps + Systems (India) Pvt. Ltd. RAJIV GANDHI INFOTECH PARK Phase 1 Ganga Estate, Survey No. 152/2/2 Above AXIS BANK Hinjewadi Pune 411 057 Tel. 0091 (0)20 640 13 923 0091 (0)20 640 08 923 Fax 0091 (0)20 229 33 923 E-mail: [email protected] www.knfpumps.in Switzerland Sales KNF Neuberger AG Stockenstrasse 6 CH-8362 Bichelsee-Balterswil Tel. 0041 (0)71 973 993 0 Fax 0041 (0)71 973 993 1 E-mail: [email protected] www.knf.ch Italy KNF ITALIA S.r.l. Via Flumendosa, 10 I-20132 Milano Tel. 0039 02 27 20 38 60 Fax 0039 02 27 20 38 48 E-mail: [email protected] www.knf.it Japan KNF Japan Co.Ltd. Chichibu, Bldg. 7F 1-8-6 Shinkawa, Chuo-ku, Tokyo, Japan 104-0033 Tel. 0081 (0)3 3551-7931 Fax 0081 (0)3 3551-7932 E-mail: [email protected] www.knf.co.jp Taiwan KNF Neuberger Ltd. 9-2 FL., No., 24, Lane 123, Section 6, Ming Chuan East Road Taipei City, Taiwan Tel. 00886-2-2794-1011 Fax 00886-2-8792-1648 E-mail: [email protected] www.knftwn.com.tw USA, Canada, South America KNF NEUBERGER, INC. Two Black Forest Road Trenton, New Jersey 08691-1810 Tel. 001 (609) 890 86 00 Fax 001 (609) 890 83 23 E-mail: [email protected] www.knf.com/usa.htm South America Direct Phone: 001 609 649 1010 E-mail: [email protected] Korea KNF Neuberger Ltd. Woosan Bldg.RM#202, 336-4, Hwikyung-Dong Dongdaemun-Ku., 130-090, Seoul Tel. 0082 (0)2 959-0255/6 Fax 0082 (0)2 959-0254 E-mail: [email protected] www.knfkorea.com KNF product centres Product centre for gas pumps: Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Phone 0049(0)7664 5909-0 Fax 0049(0)7664 5909-99 E-mail: [email protected] www.knf.de Product centre for fluid pumps: Switzerland KNF FLODOS AG Wassermatte 2 CH-6210 Sursee Phone 0041(0)41 925 00 25 Fax 0041(0)41 925 00 35 E-mail: [email protected] www.knf-flodos.ch Product centre for micro pumps: Switzerland KNF Micro AG Zelglimatte 1b CH-6260 Reiden Tel. 0041(0)62 787 88 88 Fax 0041(0)62 787 88 99 E-mail: [email protected] www.knf-micro.ch
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement