American Standard 1480.101.295 Seva 1-Handle Monoblock Bathroom Faucet Installation Instructions

Add to My manuals
7 Pages

American Standard 1480.150.002 is a single control centerset lavatory faucet with SpeedConnect™ drain, designed for easy installation and reliable performance. Its SpeedConnect™ drain feature allows for quick and hassle-free installation, eliminating the need for plumbers putty or caulk. The faucet's durable construction and sleek design make it a perfect addition to any bathroom, while its single control lever ensures effortless water flow and temperature adjustment.

advertisement

American Standard 1480.101.295 Seva 1-Handle Monoblock Bathroom Faucet Installation Instructions | Manualzz

Installation

Instructions

1480 SERIES

SEVA™

Single Control Centerset Lavatory Faucet with

SpeedConnect™ Drain

Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on

American Standard faucets.

Speed Connect™ Drain*

• Fewer parts, installs in less time

• Never needs adjustment

• Guaranteed to seal properly the first time, every time.

Certified to comply with ANSI A112.18.1

M968303 Rev. 1.4 (2/16)

*Your new American Standard faucet is designed to work only with the Speed Connect drain.

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

Recommended tools

Adjustable Wrench Screwdriver Channel Locks

1

INSTALL FAUCET

CAUTION

Turn off water at main supply.

Turn off hot and cold water supplies before beginning.

For 3-hole (4" centers) installation, put PUTTY PLATE (1) onto sink or mounting surface so it fits into the two outside holes.

Place ESCUTCHEON (2) over PUTTY PLATE (1).

Feed FAUCET SUPPLIES (5), CABLE CONNECTOR (3) and STUD (6) through O-RING (4) and through ESCUTCHEON (2).

From below, push GASKET (7) and RETAINER PLATE (8) over STUD (6) and secure with NUT (9), pushing faucet to front of sink, so STUD (6) rests against sink hole. Before final tightening, adjust faucet and

ESCUTCHEON (2) so that they are centered side to side.

6

2

1

4

7

8

9

5

3

2

POP-UP DRAIN

Remove CLEAR PLASTIC COVER (1).

Remove CARDBOARD SPACER (2) from under

DRAIN POP-UP (3).

Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B.

Fig. A.

1

3

2

3

REMOVE FLANGE

Thread FLANGE (1) counter-clockwise and remove

FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A.

Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against

LOCKNUT (3). Fig. B.

Fig. A.

1

2

4

3

Fig. B.

Fig. B.

DRAIN

BODY

4

4

INSTALL DRAIN FROM

BELOW FIXTURE

From under side of SINK install DRAIN BODY (1) up through drain outlet.

Note: No plumber’s putty or caulk is required.

The CABLE ATTACHMENT

POINT (2) must face towards the rear of the SINK.

Install FOAM GASKET (3) and

FLANGE (4) onto drain body from above SINK and tighten

FLANGE (4) firmly.

4

3

6

FLANGE GASKET AND POP-UP KNOB

Check DRAIN FLANGE in SINK to ensure that

WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A.

POP-UP KNOB (1) must be fully down. Fig. B.

REAR OF SINK

5

TIGHTEN LOCKNUT

Tighten LOCKNUT (1) firmly with Adjustable

Wrench or Channel Locks.

DRAIN

OUTLET

1

1

2

Fig. A.

WHITE FOAM

GASKET

NOT VISIBLE

DRAIN

FLANGE

Fig. B.

DOWN

1

M968303 Rev. 1.4 (2/16)

2

7

ATTACH CABLE CONNECTOR

Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. A.

Your new POP-UP DRAIN installation is now complete. Fig. B.

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

Fig. B.

Fig. A.

1

Fig. B.

2

8

CHECK OPERATION OF POP-UP

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

1-1/4” O.D.

1

2

9

MAKE WATER SUPPLY AND WASTE CONNECTIONS

Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.

Connection on fitting supplies are 3/8" compression. Connect left SUPPLY (1) to Hot (Marked with a Red Band) and right supply to COLD (2) wall supply.

Faucet supplies are 20" long from faucet base.

Note: If additional supply length is required, installer must purchase additional parts separately.

Important: If SUPPLY HOSES (1, 2) are to long, loop as illustrated to avoid kinking.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.

APPROX. 20"

1

HOT

RED

BAND

2

BLUE

BAND

3/8" COMPRESSION

COLD

M968303 Rev. 1.4 (2/16)

3

10

TEST INSTALLED FITTING

With HANDLE (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3). For model #1480.150 use

AERATOR KEY (6) to remove AERATOR (3a).

Operate HANDLE (1) to flush water lines thoroughly.

Replace AERATOR (3).

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (4) and fill lavatory with water.

Check that DRAIN STOPPER (5) makes a good seal and retains water in Sink. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.

Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary.

4

5

ON

OFF

1

COLD

HOT

3

3a

6

WASTE

OUTLET

2

“P” TRAP 2

11

SERVICE

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY

STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.

Loosen SET SCREW (2) with 2.5mm hex wrench. Pull HANDLE (1) off valve stem. Pull off

CAP (3). Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT

SAFETY STOP (4). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".

Replace ESCUTCHEON CAP (3), HANDLE (1), tighten HANDLE SCREW (2).

1

2

3

"A"

PRY RED RING FORWARD

AND ROTATE COUNTER-

CLOCKWISE ONE CLICK

"A"

TEMPERATURE

SETTING NUMBERS

"B"

PRY RED RING FORWARD

AND ROTATE CLOCKWISE

"B"

"B"

ADJUSTMENT WHEN

WATER IS TOO COLD

"A"

ADJUSTMENT WHEN

WATER IS TOO HOT

4

"RED RING"- HOT

LIMIT SAFETY STOP

12

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

M968303 Rev. 1.4 (2/16)

4

SpeedConnect™ Drain

Troubleshooting Guide

If sink does not hold water even though Stopper is in the “down” position:

• Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

• Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

• Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.

CABLE ADJUSTMENT PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. Fig. B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. Fig. B, C.

Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.

Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the

Drain Body Connection (2) and hand-tighten. Fig. A.

Fig. A. Fig. B. Fig. C.

CAM 1

RE-ATTACH

1

DOWN

CAM CAP

DISCONNECT

2

STOPPER

STOPPER REMOVAL PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.

The Stopper can now be removed by lifting it out of the Drain. Fig. F.

Fig. D. Fig. E.

REMOVE

CAM

REMOVE

CAM CAP

M968303 Rev. 1.4 (2/16)

5

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).

Locked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.

To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the

Sink and the American Standard logo is facing front. Rotate

Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.

LOGO

LOOP TOWARD

REAR OF SINK

DRAIN

Locked Mode

(Vandal Proof)

Fig.

G.

Unlocked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.

To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the

Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.

Fig. H.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable

.

LOGO

LOOP TOWARD

FRONT OF SINK

DRAIN

Fig.

Unlocked Mode

H.

Fig. J.

INSTALL CAM

CAM

Fig. K.

INSTALL

CAM CAP

M968303 Rev. 1.4 (2/16)

6

M962510-YYY0A

LIFT ROD

A912699-0070A

O- RING

M961714-0070A

MOUNTING KIT

M968303 Rev. 1.4 (2/16)

SEVA™

SINGLE CONTROL CENTERSET

LAVATORY FAUCET

MODEL NUMBER

060327-YYY0A

HANDLE KIT

1480 SERIES

907468 -YYY0A

ESCUTCHEON CAP

918633-0070A

CARTRIDGE SCREWS

923391-0070A

CAP RETAINER

023529-0070A

CARTRIDGE

M961745-0070A

MANIFOLD KIT

Replace the "YYY" with appropriate finish code

CHROME

SATIN NICKEL

002

295

M964481-YYY0A

AERATOR (1.2 GPM)

066508-YYY0A

0.5 GPM AERATOR

(MODEL #1480.150)

051012-YYY0A

ESCUTCHEON KIT

M952425-YYY0A

DRAIN ASSEMBLY

M919660-0020A

6” TAILPIECE

(NOT INCLUDED

WITH FAUCET)

M962544-YYY0A

STOPPER

ASSEMBLY

M952430-0070A

CABLE ASSEMBLY

M962457-007A

FLANGE

ASSEMBLY

M922872-0070A

CAM SEAT INSERT

M962430-0070A

CAM ASSEMBLY

M913207-0070A

TAILPIECE INSERT

A919661-0020A

TAILPIECE

M962458-0070A

DRAIN MOUNTING KIT

Product names listed herein are trademarks of AS America, Inc. ©2016

7

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST

Saturday 10:00 a.m. to 4:00 p.m. EST

IN CANADA 1-800-387-0369

(TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

IN MEXICO 01-800-839-1200