Hinkley Lighting Parker 4433 KZ chandelier Assembly instructions

Hinkley Lighting Parker 4433 KZ chandelier Assembly instructions

Add to My manuals
3 Pages

Below you will find brief information for chandelier Parker 4433 KZ. This assembly instructions will guide you through the step-by-step process of installing your new chandelier. It includes instructions on how to assemble the fixture, install mounting hardware, connect wiring, and hang it from the ceiling.

advertisement

chandelier Parker 4433 KZ assembly instructions | Manualzz
4433
assembly instructions
Family: Parker
Drawing 1 - Fixture Assembly
120º
Item No. 4433 KZ
start he re
A
A
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
A
3. Carefully review instructions prior to assembly.
Drawing 2 - Fixture Assembly
*** The construction of this fixture will be accomplished by first assembling the
main body structure, installing the mounting hardware to the junction box, hanging
the fixture from the ceiling and then installing the fixture glass.
2
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
3
1. Rotate arms (A) outward from current position until they are equally spaced,
approximately 120 degrees apart - see Drawing 1.
2. Refer to hanging instruction sheet (I.S.19) provided to hang fixture. Then refer back
to this sheet to continue installation of this fixture.
3
1
1. Remove threaded socket ring (2) from socket (1) - see Drawing 2.
2. Slip glass (3) over socket (1).
3. Thread socket ring (2) onto socket (1) to secure glass (3).
4. Fixture can now be lamped accordingly.
A
3.16.09
HINKLEY LIGHTING
33000 Pin Oak Parkway Avon Lake, OH 44012
800.446.5539 / 440.653.5500
hinkleylighting.com
s tar t he re
Drawing 1 - Han
ging Assembly
A
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
3c
1
2
1. Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove
the appropriate fuse (or open the circut breakers) until the fixture is dead.
GS
• DO NOT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
3b
3a
4
1. fasten mounting strap (1) to outlet box (A) with the two 8-32 screws (2) -see
Drawing 1.
5
B
hanging instructions
I.S. 19
I.S.19
2. Thread 2 - hex nuts (3a) and (3b) onto threaded tubing (4).
3. Thread one end of threaded tubing (4) into loop (5) a minimum of 1/2” to 3/4”.
Thighten hexnut (3a) against loop (5) to lock loop in position.
4. Thread other end of threaded tube (4) into mounting strap (1) approximately 1/2”.
5. Slip canopy (B) over loop (5) and adjust height of loop so half of the threaded area
on the loop is exposed - see Drawing 2 below. After loop height is adjusted, thigten
hex nut (3b) up against mounting strap, tighten against mounting strap to lock loop
and threaded tube in position.
6
C
weave supply wire and
ground wire through chain
6. Remove mounting strap (1) from junction box (A), and thread third hex nut (3c) onto
end of threaded tube (4) above the mounting strap, tighten against mounting strap
to lock assembly in position.
7. Remount mounting strap to junction box.
1. Taking the chain, determine the length you require to hang the fixture.
2. Attach one end of the chain to the top loop of the fixture - see Drawing 2.
3. Now slip loop collar (5) and canopy (B) onto chain.
4. Attach other end of chain to loop (4). Get assistance for this step since fixture
may be heavy and difficult to hold while attaching the chain.
Drawing 2 -Canopy Adjustment
1. Unwrap supply wire and ground wire and weave them up through the chain.
2. Slip supply wire and ground wire through center of loop (4).
3. Connect ground wire to mounting strap (1) using green ground screw (6).
4. Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet (I.S. 18) and follow all instructions to make all necessary
wiring connections.
half of threaded area
exposed
HINKLEY LIGHTING
5. Slip canopy up firmly against the ceiling and secure by turning the threaded
collar (5) on loop (4) until tight.
3 3 0 0 0 Pin Oak Par kway,
Avon Lake, O H 44012
800.446.5539 / 440.653.5500
hi nkl eyl i ghti ng.c om
grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Drawing 1 - Flush Mount
supply wire
A
C
Indoor Fixtures
E
1
2
twist-on
connectors
D
B
fixture leads
Drawing 2 - Chain Hung
supply wire
A
C
E
twist-on
connectors
1
B
D
E
wiring instructions
2
fixture leads
1. Connect positive supply wire (A) (typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all
electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
• If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a
fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all
electrical connections.
Drawing 3 - Post-Mount
grounding instructions
supply wire
A
C
E
twist-on
connectors
E
B
D
fixture leads
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1)
with the ground screw (2) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the
head of the ground screw (2) on fixture mounting strap (1) and connect to the
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power
supply ground with appropriately sized twist-on connector inside post. Cover open
end of connector with silicone sealant to form a watertight seal - see Drawing 3.
HINKLEY LIGHTING
33000 Pin Oak Parkway Avon Lake, OH 44012
800.446.5539 / 440.653.5500
hinkleylighting.com
I.S. 18
I.S. 18 wiring

advertisement

Key Features

  • Detailed instructions
  • Clear diagrams
  • Safety warnings
  • Wiring and grounding instructions
  • Hanging instructions

Frequently Answers and Questions

How do I assemble the chandelier?
Refer to the assembly instructions provided in the document. It includes detailed diagrams and instructions on each step.
What safety precautions should I take during installation?
Always turn off the power supply before starting installation. Read and follow the wiring and grounding instructions carefully. Consult a qualified electrician if you need new wiring.
How do I hang the chandelier from the ceiling?
Refer to the hanging instructions provided in the document. It includes steps on how to attach the mounting strap, thread the tubing, and connect the chain.
How do I connect the wiring?
Read and follow the wiring and grounding instructions provided in the document. Make sure to connect the positive and negative supply wires to the corresponding fixture leads. Use twist-on connectors and ensure a secure connection.
What if I need additional help with the installation?
Consult a qualified electrician or local authorities for code requirements if you need help with the installation.