Action Instruments™ DIN Rail Mount Signal Conditioners, Isolators

Action Instruments™ DIN Rail Mount Signal Conditioners, Isolators
Action Instruments™ DIN Rail Mount Signal Conditioners,
Isolators, Alarms, and Power Supplies
• Wide Ranging and Field Configurable
for Maximum Flexibility
• ASIC Based Design for Maximum Reliability
• Lifetime Warranty
• High Density DIN Rail Mount Saves Panel Space
Ultra SlimPak
Ultra SlimPak offers a wide selection of functions, input
types and ranges. These modules accept most
process signals and output the commonly
required voltages, current, and alarm trips.
SPECIFICATIONS
Isolation:
Humidity:
Temperature Range
Operating:
Storage:
Power
Consumption:
Range:
Alarm Relays:
EG12:
Agency Approvals:
0 to 55°C
-25 to 70°C
1.5W typical, 2.5W Max.
9 to 30 VDC
5A @ 120 VAC or 28 VDC
2A @ 240 VAC
SIGNAL
CONDITIONERS
Housing:
EG8:
1800 VDC between input, output, and power
15 to 95% (@45°C) Operating
0.5"W x 3.54"H x 4.34"D, including rail
(12.6 x 90 x 110.2mm)
0.7"W x 3.54"H x 4.34"D, including rail
(17.7 x 90 x 110.2mm)
CSA per C22.2, UL per UL508, CE
SPECIFICATIONS AND ORDERING INFORMATION
Cat #
G408
Function
Isolator
G108
Limit Alarm
G418
Isolator
G118
Limit Alarm
G428
Isolator
G438
Isolator
Input Span (Field Configurable)
10 mV to 100V
DC Volt
1 mA to 100 mA
DC Current
10 mV to 200V
1 mA to 100 mA
Bipolar switch for ±100% span
Platinum RTD
RTD
25°C to 800°C
Copper RTD
25°C to 468°C
B: 500°C to 1820°C
E: -150°C to 1000°C
Thermocouple J: -200°C to 750°C
K: -200°C to 1370°C
R/S: 50°C to 1760°C
T: -150°C to 400°C
Pot
100 ohms to 100k ohms
G448*
Isolator
Strain Gauge
G468
Isolator
G168
Limit Alarm
G128
Limit Alarm
Input
AC Voltage
AC Current
G478
Isolator
Frequency
WV905
Power Supply AC Power
*Requires 18-30VDC power supply
0.5 mV/V to 50 mV/V
Adjustable Excitation: 1–10 VDC, 120 mA
50 mVAC to 200 VAC
5 mA AC to 5 AAC**
2 Hz to 10 kHz
100 to 240 VAC; 50 to 60 Hz
Housing
EG8
EG12
EG12
Output (Field Configurable)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
Alarm (Dual SPDT Relay)
EG12
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
Alarm (Dual SPDT Relay)
EG12
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG12
Alarm (Dual SPDT Relay)
EG8
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG12
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG8
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG12
Alarm (Dual SPDT Relay)
DC Voltage (0–5V, 0–10V)
EG8
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
17.5mm
24 VDC @ 500 mA
**1 to 5AAC range requires C006 0.1Ω shunt
80
Action Instruments™ IQ Signal Conditioners
• Multi-Channel DC, RTD, T/C Conditioners—Lower Cost/Point
• Ideal for Large Numbers of Data Points
• Extreme Operating Temperature—from -40 to 80°C
• SnapLoc Terminal Blocks
• Optional I/Q Rail Power Bus—Saves Installation Time
• Interlocking Modules—Solid, Reliable Mounting
SPECIFICATIONS
Isolation:
Humidity:
Operating Temperature:
Power:
SIGNAL
CONDITIONERS
HOW TO ORDER—Select the unit with the
output of your choice and then add the code that
identifies the input range to satisfy your application.
Example: Q510-4004 is a 4-channel RTD Input,
2-wire transmitter, with a 0–250°C range and
4–20 mA output.
DC ORDERING INFORMATION
4-20 mA
1-Channel
2-Channel
4-Channel
Q500
-1000
-2000
-4000
DC ORDERING INFORMATION
Input Range
4–20 mA
0–10V
0–5V
1–5V
Q501 (1 Ch)
-1000
-1003
-1004
-1005
Q501 (2 Ch)
-2000
-2003
-2004
-2005
Type J
-0001
-0002
—
—
-0003
—
Type K
-0004
—
-0005
—
—
-0006
Q510
Q488
Q520
Q438
Q448
Input Type
DC Current
DC Current
DC Volts
3-wire RTD Pt100Ω
TC (B, C, E, J, K, N, R, S, T)
Pt RTD (100, 200, 500,
1000), Cu RTD (9),
Ni RTD (120),
90mV, 900mV, 4000Ω
T/C (J,K,T)
Potentiometer
Bridge
81
Range
0–20/4–20 mA
4–20 mA
0–5V, 0–10V,1–5V
See Below
-270 to +1370°C
(type K)
-200 to +850°C
(Pt 100)
See Blow
100Ω to 100kΩ
±5mV to ±200mV
Output
Channels
0–20/4–20 mA 1, 2 or 4
4–20 mA
1 or 2
4–20 mA
0-1mA,
4-20mA,
0–5V,
0-10V
4–20 mA
0-1mA,
4-20mA,
0–5V,
Q478
Frequency
2Hz — 10kHz
0-10V
T/C cold junction compensation (standard). Output linear to mV input.
Type T
-0007
—
—
-0008
—
—
ORDERING INFORMATION—ACCESSORIES
Mounting Hardware
MD02
MD03
IQRL-D002
IQRL-D004
IQRL-D008
Q488
ACTION I/Q SIGNAL CONDITIONERS
Cat #
Q500
Q501
Q520 (T/C) ORDERING INFORMATION
Temp Range
0–500°F
0–1000°F
0–2000°F
0–250°C
0–500°C
0–1000°C
L
Response Time:
Approvals:
From 1800 to 4000 VDC,
input to output and channel to channel
15–90% @ 45°C
40 to 80°C (Q5XX Series)
0 to 55°C (Q4XX Series)
12 to 35 VDC output loop (Q5XX Series)
18 to 30 VDC output common (Q4XX Series)
100 mSec (10–90%) typical
UL508, CSA C22.2, CE
TS32 DIN Rail (2m) Slotted (G-rail)
TS35 x 7.5 DIN Rail (2m) Slotted (H-rail)
IQ Rail for 2 Modules (Q488 only)
IQ Rail for 4 Modules (Q488 only)
IQ Rail for 8 Modules (Q488 only)
Circuit Type
Input Loop Powered
Isolated 2-Wire Transmitter
2 or 4
1
2-Wire Transmitter
Isolated 2-Wire Transmitter
(2, 3 or 4-wire input)
2
1
1
Isolated 2-Wire Transmitter
3-wire to 2-Wire Transmitter
Isolated 4-wire to 2-Wire
Transmitter
Isolated 2-Wire Transmitter
1
Q510 (RTD) ORDERING INFORMATION
Temp Range
0–100°C
0–150°C
0–200°C
0–250°C
0–500°C
0–200°F
0–300°F
0–400°F
0–500°F
0–1000°F
Q510 (2-Ch)
-0001
-0002
-0003
-0004
-0005
-0006
-0007
-0008
-0009
-0010
Q510 (4-Ch)
-4001
-4002
-4003
-4004
-4005
-4006
-4007
-4008
-4009
-4010
Other inputs & AC powered modules also available.
Action Instruments™ Isolating Action Instruments™ DC Input,
Field Configurable Isolator
Two-Wire Transmitter
• Isolated, Linearized Current Loop Output
with Math Functions
for an RTD or Thermocouple Input
• HART Compatible or Field
Configurable with Optional Display
• Intrinsically Safe Operation or with
Display and EP Enclosure
• Programmable for 11 T/C Types,
6 RTD Types, mV or Ohm inputs
• Multi-Function, Multi-Channel Input.
• DC-Frequency or Frequency-DC
Conversion for Totalization/
Integration Applications.
• Math Capability Supports
Many Process Control Functions.
• Switch Selectable or PC Programmable Ranges.
L T79D
The model T798 is a programmable temperature transmitter that
can be factory or field configured using the optional 1 or 2 line
alphanumeric display.
The model T798 is Highway Addressable Remote Transducer
(HART) based, temperature transmitter that can be factory or field
configured using an optional 1 or 2 line alphanumeric display,
optional PC based modem and software. Alternatively an HC275
Hand-Held Communicator loaded with the Action T798 Device
Description from the Hart Foundation Library can be used.
The Q498 can perform single or double input math calculations on
the input values. The available operators are: +, -, *, /, Sq, Sqroot
& Average. Process control functions include Hi/Lo Select, Rate of
Change Limiter and Track & Hold. The frequency input can also
have the math functions applied. A 25-point linearization function
is available for Channel 1 Analog input only. All output math and
process control functions require the C698 software.
SPECIFICATIONS
Linearization:
Thermocouple and RTD linearization to ±0.05°C.
Output:
Analog, two-wire 4-20 mA
Transmitter Accuracy: ±0.05% of the millivolt or ohm equivalent input
reading, or the value from the Accuracy Table,
whichever is greater; plus ±0.05% of the span.
For thermocouples, add ±0.5°C (0.9°F) for
cold junction compensation.
Output
Analog Zero: 100% of Sensor range —Non-interacting
Adjustments:
Analog Full-scale: Normal or Reverse Acting
Operating Temperature: Electronics & Display (with reduced visibility):
-40°C to 85°C, (-40°F to +185°F)
Display (full visibility): -20°C to +70°C,
(-4°F to +158°F)
ORDERING INFORMATION
T797-0000
T797-1000
T798-0000
T798-1000
Displays & Options
T79D-2000
T79D-1000
T79E-1000
T79A-P000
T79A-D000
T79A-M000
T79A-MH00
T79A-C000
Temperature Transmitter, Non IS
Temperature Transmitter, IS-FM/CSA
Temperature Transmitter, Hart, Non IS
Temperature Transmitter, Hart, IS-FM/CSA
Two Line Alphanumeric Display
One line alpha-numeric Display
Weather Proof Head-Mount Enclosure
Pipe Mount Bracket for T79E-0/D only
DIN Rail Mounting Kit
T797 Configuration Modem
T798 Hart Configuration Modem
Configuration Software for T797 & T798
SPECIFICATIONS
Analog Input Ranges
(Two Isolated Channels)
Analog Maximum Overload
(continuous)
Analog Output Ranges
Analog Output Drive
±150mV, ±1.5V, ±15V, ±150V
±2.5mA, ±25mA
200V DC for voltage inputs; 170mA DC and/or
60V DC maximum for current inputs (self-resetting fuse)
0-20mA, 0-10V, ±10V
0-20mA: 12VDC compliance. (600Ω maximum)
Voltage ranges: 10mA drive (1000Ω load minumum)
Analog Output Accuracy
±0.005% of the FS Input Range (±0.05% on 150 volts
range), plus ±0.05% of the FS Output Range
(±0.1% for output loads <200Ω)
Analog Response Time
750msec max. (10-90%)
Analog Input Impedance ≥100kΩ on voltage ranges > 1.5V,
≥10MΩ on voltage ranges <1.5V
70Ω typical (non-overload) on all current ranges
Analog Output Impedance Less than 3Ω on voltage output ranges
≥ 500kΩ on current output ranges
Frequency Input
One channel with two voltage range inputs:
150mV to 50Vrms with 5Vp noise suppression,
or 0.5V to 150Vrms with 20Vp noise suppression,
2Hz to 10kHz in software selectable ranges.
Frequency Output
±0.1%, 2Hz to 10kHz in software selectable ranges
Open collector pulled up through 20k to 18V, with
1mA drive.Sinks up to 20mA from 24V external supply.
Discrete Input
Input active to Common, with soft pull-up (1mA) to +18V
CMR (DC to 60Hz)
≥90dB for 60Hz and 120dB @ DC
Power Requirements
9-30VDC, 2.5 watts max
Isolation
Input to Input to Output to Power, 1800VDC
Size
DIN rail case (0.88" x 4.0" x 4.59")
Operating Temperature
0°C to + 55°C (32 to 131°F)
ORDERING INFORMATION
Q498-0000
C698-0000
H902
H910
H915
DC–Frequency Isolator
Configuration Software & PC Serial Cable
0.2Amp, 24VDC Power Supply
1Amp, 24VDC Power Supply
2.3Amp, 24VDC Power Supply
82
SIGNAL
CONDITIONERS
Both the T798 and T797 accept thermocouple (B, C, E, J, K, L, N,
R, S, T, U & special) and 2, 3, or 4 wire Platinum RTDs (385 or 392
alpha) as well as millivolt (mV) and resistance inputs.
The Q498 is a DC powered, DIN rail mount, DC input signal
conditioner. The unit is fully isolated to 1800V between input,
output and power. Two isolated analog inputs each accept either a
DC voltage or current. One analog output delivers either DC bi-polar
voltage or uni-polar current. The Q498 also has a separated
frequency input channel and a frequency output, as well as a
discrete input and output channel.
Action Instruments™ Low Profile Signal Conditioners
ORDERING INFORMATION
• Low Power
• Higher Accuracy
• Field Configurable
• E-Mail Alarm Notification
SlimPak II
Model
WV408-2000
SPECIFICATIONS
SIGNAL
CONDITIONERS
Output:
Accuracy (In/Out):
Isolation:
Operating Temp:
Power:
Alarm:
Size:
Approvals:
0-10V, 0-20mA, 4-20mA
±0.015% rng / ±0.05% rng
1800V AC/DC, In/Out/Power
0 to 60°C, <95% RH
9-30VDC, 1W typ.
2 SPDT, [email protected]
0.5" wide DIN rail case
UL508, CSA C22.2, CE
Function
DC
Range
±150mV, 1.5/15/150V,
2.5/25mA +reverse
WV418-2000
RTD
2/3/4 wire: Pt100, Cu10
WV428-2000
T/C
J,K,T,R,S,E,B,N,C,B
WV438-2000
Potentiometer
100Ω to 100kΩ
WV448-2000
Bridge
±5/10/20/50/100/200mV
(1-10VDC, 120mA excitation)
WV468-2000
AC
50/150/500mV,
5/20/50/150/250V,
20/100mA
+reverse (40-400Hz)
WV478-2000
Frequency
0-10kHz (150mV-150V)
WVC16-2000
Communication Up to 32 modules to
Ethernet 10Base-T
C650-2000
Software
Includes serial cable
WV905
Power Supply
24VDC @0.5A
Also available as Limit Alarms with latching relays & reset switch
Pyromation Temperature Transmitters
• Wide Operating Temperature Range
SPECIFICATIONS
• Factory or Field Configurable
Input:
• Sensor Break & Short Circuit Detection
• T/C Head Mounting (441 & 442)
Industrial or Explosion Proof Housing (642)
• FM & CSA Approved Intrinsically Safe & Non-Incendive
642
441
Accuracy:
Output:
Maximum Load:
Power Supply:
Operating Temperature:
Dimensions (441, 442):
Galvanic Isolation:
T/C J,K,T,E,R,S,B,N,L,U,C,D
RTD Pt or Ni, 100/500/1000, 2/3/4-wire
DC -10 to 100mV
Resistance 400Ω, 2000Ω
0.2°C (Pt100), 1°C (K T/C)
2-wire, 4-20mA or 20-4mA
(Vsupply - 8V)/25ma
8-30V DC (40V max on 642 models)
-40 to 85°C, condensing allowable
1.73" dia x 0.9" (44x23mm)
3.75kV AC
ORDERING INFORMATION
PM/441
Temperature Head Transmitter
PM/442
Temperature Head Transmitter with HART® protocol
PM/642A
Programmable HART® Transmitter
PM/642AT
Programmable HART® Transmitter with digital display
PM/642C
Programmable HART® Transmitter, explosion proof housing
For factory configuration, specify input type & range (°C or °F); for field
configuration, order communication cable & software
NLS Series 8000 Signal Conditioners
• Input, Output, Isolation, Power Supply and Special Functions Combined in
One Low Cost Modular Unit
• Field-Settable Range, Span and Configuration
• Fuse Protected Linear Power
8000-1-1
• UL Recognized
• High Impact, Flame Retardant Polycarbonate Case
The Series 8000 signal conditioners are designed with a modular architecture to allow full input, output, and
special function selectability and interchangeability. They can also be used as isolators, signal amplifiers, and
transmitters.
85
Action Instruments Plug-In Signal Conditioners,
Isolators and Alarms
ENVIRONMENTAL SPECIFICATIONS
Isolation
Between Input, Output and Power
Limit Alarms:
1000 VDC
Signal Conditioners:
1500 VDC
Temperature Range:
Operating: 0 to 60°C
Signal Conditioners:
1500 VDC
Humidity:
15 to 95% (@45° C)
Power:
120 VAC ±10%, 50/60 Hz
Consumption:
30W Typical, 5W Max
Agency Approvals:
CSA per C22.2 and UL per UL508
ActionPak
▲
SPECIFICATIONS AND ORDERING INFORMATION
Model #
AP4380
AP4390
AP4382
AP1080
AP1090
Function
Isolator Single
Isolator Dual
Isolator (Bipolar Output)
Limit Alarm Single
Limit Alarm Dual
AP4351
Isolator
AP1280
AP1290
Limit Alarm Single
Limit Alarm Dual
AP4081
Conditioner
AP6380
Conditioner
Input
DC Volt
DC Current
Input Span (Field Configurable)
10 mV to 100V
1 mA to 100 mA
DC Volt
DC Current
Bridge
10 mV to 200V
1 mA to 100 mA
B: 500°C to 1820°C
E: -150°C to 1000°C
J: -200°C to 750°C
K: -200°C to 1370°C
R/S: 50°C to 1760°C
T: -150°C to 400°C
10 mV to ±200 mV
50 mV to 200 VAC
5 mA to 100 mA AC
10mA to 100 mA AC
2 Hz to 10 kHz
Thermocouple
AP1690
AP7380
Limit Alarm Single
Conditioner
AC Voltage
AC Current
Frequency
AP7500
Conditioner
DC (Fixed Range)
AP7501
Conditioner
DC (Fixed Range)
AP4003
Conditioner
Potentiometer
(Wide Ranging)
Specify: 4–20 mA, 0–10V,
1–5V, 0–5V, 0–10V, or 10–50 mA
Specify: 4–20 mA, 0–10V,
1–5V, 0–5V, 0–10V, or 10–50 mA
Specify: 0–100% pot
100Ω to 100Ω pots
Output (Field Configurable)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
DC Voltage (±5V, ±10V)
Single Trip (DPDT, 5A)
Single/Dual Trip (2 SPDT, 5A)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
Single Trip (DPDT, 5A)
Single/Dual Trip (2 SPDT, 5A)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
Single/Dual Trip (2 SPDT, 5A)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
Frequency (0–9 ppm up to
0–10 kHz) TTL: 0/6V
Frequency (0–0.12 ppm up to
0–130 ppm) DPDT Relay: 5A Max
DC 0-20mA, 4–20 mA, 0–5V, 0–10V
MOUNTING ACCESSORIES FOR ACTION PRODUCTS
Mounting Hardware (for ActionPak IQ and SlimPak)
MD02
TS32 DIN Rail, 2 Meters, Slotted (G-Rail)
MD03
TS35 x 7.5 DIN Rail, 2 Meters, Slotted (H-Rail)
Mounting Hardware (for Action Pak Only)
MD08
8-Pin DIN Rail Socket (Surface or Rail Mountable)
MD11
11-Pin DIN Rail Socket (Surface or Rail Mountable)
These sockets mount on standard DIN Rails MD02 or MD03
88a
84
Only a few products from each manufacturer are shown
on our website.
Please call 800-903-9870 or 440-238-2550 for information
and assistance on the product you selected.
WESCHLER INSTRUMENTS
Manufacturer & Distributor of Meters, Instruments
and related equipment
MANUFACTURERS
Action Instruments
Adalet
AEMC
Alaron
Altek
Amprobe
API (Absolute Process)
Applied Technical
Ashcroft
ATC (Westcon/Diversified)
Bacharach
Control Switches
Crompton
Dixson
EIL
Electro Industries
E-Mon D-Mon
Empro
ENM
Extech
Flexcore
Fluke
Fuji Electric / TTI
Hioki
Hoyt
Instrument Transformer
International Instrument
Ideal
Jewell
Kessler Ellis (KEP)
Kobold
Laurel Electronics
LFE
London Electronics
Madison
Martel / Beta
Megger / Biddle
Meterman
MeterMaster
Midwest Transformers
Modutec
Monarch
National Meter
Newport
NK Technologies
Non-Linear Systems
Noshok
Partlow
Pyragon
Pyromation
Raytek
Red Lion
Selco / Asahi
Simpson
Texmate
Transmation
Triplett
Vaisala
VAS / Doric
Veris
Weschler
Westinghouse
Weston (A&M)
Yokogawa
PRODUCTS
Meters
Analog
Digital
Bargraph
Panel
Process
Power
Switchboard
Mil Spec
Large Display
Meter Relays
Sensors
Temperature
Pressure
Flow
Strain
Position
Load
Voltage
Current
Speed
Level
Humidity
Vibration
Transducers
Current Transformers
Potential Transformers
Shunts
Signal Conditioners
Isolators
Transmitters
Looop Splitters
Alarms
Switches
Test Equipment
Multimeters
Clamp-On Meters
Thermometers
Humidity Meters
Light Meters
Megohmmeters
Hipot Testers
Ground Testers
Insulation Testers
Cable Testers
Power Analyzers
Process Calibrators
Miscellaneous
Counters
Timers
Clocks
Controllers
Recorders
Data Loggers
Power Supplies
Protection Relays
Enclosures
& More
• www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
NEW
Laurel DIN Rail Transmitters
• Analog and Pulse Inputs
• Serial & Analog Outputs
• RS-232 or RS-485 Communications
• Dual Relay Outputs
• Input/Digital/Analog/Relay Isolation
• Free Setup Software
The Laureate transmitters provide serial data
conversion and analog retransmit for all popular industrial signals. These modules use
the proven circuitry of the Laurel panel
meters for exceptional accuracy at high
update rates.
LTA
L
All Laureate transmitters are easily configured from a PC using the
graphical Laurel Instrument Setup Software. The isolated analog output can be digitally scaled to any portion of the full range. Dual relay
outputs add alarm and control capability. Programmable modes
include operation above or below setpoint, latching or non-latching,
hysteresis and band deviation.
Each DC transmitter is precalibrated for all DCV & DCA ranges. The
user can change the range without recalibration. On the temperature
transmitter, thermocouple or RTD type is field selectable.
Measurement range can be as wide as the entire span of the sensor
type or as narrow as 15°. Cold junction compensation and open
sensor detection are included.
Standard functions on pulse input models are frequency, rate, period,
A to B interval, up/down total to 999999. The extended model provides additional user-configurable functions.
SPECIFICATIONS
Digital Output:
Protocol:
Baud Rate:
Accuracy:
ACCESSORIES
CBL04 RS-232 cable to PC serial port or USB adpator
CBL02 USB to RS-232 cable adapter
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number
Order Example: LTA200DCV1
A
A
B
C
D
B
C
D
Model
LTA2
Standard analog inputs
LTA4
Extended analog inputs*
LTA6
Standard pulse/frequency input**
LTA8
Extended pulse/frequency input**
Power
0
85-264VAC ±10%, 90-300VDC
1
12-30VAC, 10-48VDC
Setpoint Output
1
Dual isolated solid-state relays
Input Type (LTA2 or LTA4)
DCA4
DCV1
200mV DC
RMV1
DCV2
2V DC
RMV2
DCV3
20V DC
RMV3
DCV4
200V DC
RMV4
DCV5
600V DC
RMV5
DCV6
300V DC
RMV6
DCA1
2mA DC
RMA1
DCA2
20mA DC
RMA2
DCA3
200mA DC
P
P1
SG
SG1
WM
WM1
P385
P392
Process 4-20mA in/out
Process Custom mA scaling
Strain Gage 200mV
Strain Gage Custom
Load Cell 20mV
Load Cell Custom
100Ω Pt RTD α=385
100Ω Pt RTD α=392
J
K
R
S
T
E
N
SIGNAL
CONDITIONERS
RS-232 or RS-485 (2- or 4-wire)
Modbus RTU, Modbus ASCII or Laurel ASCII
300-19200
DCV, mA: ±0.01% of FS ±2 counts
ACV, mA: ±0.15% of FS ±2 counts (10Hz-10kHz)
Strain gage, load cell: ±0.01% of FS ±2 counts
RTD: 0.1°C
Thermocouple: 0.2°C
Update Rate:
50 or 60/sec for analog inputs
Load Cell/Strain Gage: 20, 50, 100, 250, 500mV ranges
Thermocouple:
FS range is maximum for each sensor type
Frequency/Pulse Input: AC, magnetic pickups, pulses from NPN or PNP
transistors, contact closures, digital logic
Channel A Frequency: 0.005Hz to 1MHz
Channel B Frequency: 0.005Hz to 250kHz
Time Base Accuracy: ±2ppm
Signal Level:
12mV min, 250VAC max
Update Rate:
Gate time + 30ms + 1 period (20/sec at 60Hz)
Gate Time:
0.01 to 199.99 sec (selectable)
Curve Fitting:
Square root extraction standard,
Custom curve fitting with LTA8
Quadrature Input:
Differential or single ended
Transitions Monitored: x1, x2 or x4
Transitions/sec:
250k max.
Error Correction:
Zero index (Z-channel)
Analog Output:
4-20mA, 0-20mA, 0-10V
Compliance (mA):
10V (0-500Ω load)
Compliance (V):
2mA (>5kΩ load)
Accuracy:
±0.02% of span (analog inputs)
±0.01% of span (pulse inputs)
Resolution:
16 bits (65536 steps)
Power:
DC or 47-63 Hz
Relay Outputs:
Two SPST-NO (Form A) solid-state relays
[email protected]/180VDC
Excitation Output:
[email protected], isolated 50V from signal gnd
(DC, Process & FR
[email protected], isolated 50V
inputs, jumper
[email protected], isolated 50V [DC & Process inputs]
selectable)
[email protected], non-isolated [FR input]
Isolation:
250Vrms power/analog/digital
Temperature:
0-55°C operating
Size:
120 x 101 x 22.5 mm
Mounting:
35mm DIN rail
Connections:
Detachable screw terminal plugs
5A DC
200mV AC Trms
2V AC Trms
20V AC Trms
200V AC Trms
600V AC Trms
300V AC Trms
2mA AC Trms
20mA AC Trms
Type J TC
Type K TC
Type R TC
Type S TC
Type T TC
Type E TC
Type N TC
D
Input Type (LTA6 or LTA8)
FR
Dual channel frequency/pulse**
VF1
4-20mA (process totalizing)
VF2
0-1mA (process totalizing)
VF3
0-10V (process totalizing)
QD
Quadrature***
* LTA4 adds custom curve linearization & rate from successive readings.
** LTA6 scalable for frequency, rate, totalizing, timing. LTA8 adds phase
angle, duty cycle, up/down counting, rate & total simultaneously, custom
linearization, arithmetic functions (A+B, A-B, AxB, A/B, A/B-1).
*** LTA6 scalable for position. LTA8 adds scalable rate.
84
Laurel Serial to Analog Transmitter
L
• RS-232 & RS-485 Input
• Isolated 4-20mA or 0-10V Output
• ASCII & Modbus Protocols
• AC or DC Power
• DIN Rail Mount
TS6
• Dual Relay Outputs
NEW
The Laureate serial-to-analog transmitter is able to retrieve digital
data from long character strings. You can specify character positions, start and stop ASCII characters, how many characters to skip
and how many characters to pass. Modbus RTU, Modbus ASCII and
Laurel ASCII protocols are supported.
The 16 bit analog output is isolated from the power and digital sections. Span is field adjustable using the Laurel setup software.
Update rate to 60/sec provides rapid response.
SPECIFICATIONS
Serial Input:
Baud Rate:
Analog Out:
Compliance (mA):
Compliance (V):
Accuracy:
Resolution:
Isolation:
Relay Outputs:
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: TS602
TS6
A
B
A
B
Power
0
85-264VAC ±10%, 90-300VDC
1
12-30VAC, 10-48VDC
Setpoint Output
0
None
1
Dual isolated solid-state relays
Accessories:
CBL04
CBL02
RS-232 cable to PC serial port or USB Adapter
USB to RS-232 cable adapter
SIGNAL
CONDITIONERS
Temperature:
Size:
Mounting:
Connections:
ORDERING INFORMATION
RS-232 or RS-485 (2- or 4-wire)
300-19200
4-20mA, 0-20mA or 0-10VDC (selectable)
10V (0-500Ω load)
2mA (>5kΩ load)
±0.02% of span
16 bits
250Vrms power/analog/digital
Two SPST-NO (Form A) solid-state relays
[email protected]/180VDC
0-55°C operating
120 x 101 x 22.5 mm
35mm DIN rail
Detachable screw terminal plugs
API Frequency to DC Transmitters
L
• 0-1mA, 4-20mA, 0-1V or ±10V Output
• 2000V Isolation
• Simple field setup (7580)
• Input & Output Status LEDs
• Functional Test Button
7580
• Lifetime Warranty
These API transmitters accept a frequency input and provide an optically isolated DC voltage or current output that is linearly proportional to the input.
ORDERING INFORMATION
To Order—Insert Code for Each Letter to Select Catalog Number.
Order Example: API 7010GDU
A
A
B
B
Model
API 7010G
API 7580G
Options
A230
D
U
HC
M09
EXTSUP
Accessories:
API 008
API 008FS
API TK36
Frequency to DC Transmitter, 115VAC, factory ranged
Frequency to DC Transmitter, 115VAC, field rangeable
Powered by 230VAC ±10%, 50/60Hz, 2.5W max
Powered by 9-30VDC, 2.5W typical
Conformal coating for moisture resistance
High current output to 50mA (7010G only)
High voltage output to 24VDC (7010G only)
Open collector [sink] output (7010G only)
8-pin octal socket
Finger safe 8-pinoctal socket
35mm DIN rail, 39” long, aluminum
Plug-in API transmitters/isolators are available for most sensors & process signals.
Full three-way isolation makes these modules useful for ground loop
elimination, common mode signal rejection and noise pickup reduction.
The input and output ranges on the 7580 are field configured via
switches - no software required. Ranges on the 7010 are factory set
and must be specified when ordered. The internal loop supply can be
used to power external devices, often eliminating the need for a separate supply.
SPECIFICATIONS
7010 Input Range:
Factory set - specify on order
Minimum 0-25Hz, maximum 0-20kHz
7580 Input Range:
Field selectable via rotary switches and tables
Low range: Min 0-100Hz, max 0-1500Hz
High range: Min 0-2kHz, max 0-30kHz
Input Voltage:
100mVrms - 150Vrms
Input Impedance (min): 10kΩ (7580), 100kΩ (7010)
Input Sensitivity:
25mV to 2.5V (pot adjustable)
Output Ranges:
0-1V min, 0-10V max,
±1V min, ±10V max (bipolar mode),
0-2mA min, 0-20mA max (current mode).
Factory set on 7010 - specify on order,
Field settable on 7580
Compliance (mA):
20V, 1000W
Output Zero Adjust:
±15% of span
Output Span Adjust:
±10% of span
Accuracy:
Better than ±0.2% of span
Response Time (typ):
70msec (7010), 110msec (7580 hi range),
600msec (7580 lo range)
Isolation:
2000Vrms power/input/output
Loop Supply:
18VDC unregulated, 25mA max.
Power (standard):
115VAC ±10%, 50/60Hz, 2.5W max
Temperature:
-10 to 60°C operating
Status Indicators:
Variable brightness LEDs indicate level & status
Connections:
8-pin octal socket (order separately)
88
Action Instruments™ Low Profile Signal Conditioners
• Low Power
• Higher Accuracy
• Field Configurable
• E-Mail Alarm Notification
L
SlimPak II
SPECIFICATIONS
SIGNAL
CONDITIONERS
Output:
Accuracy (In/Out):
Isolation:
Operating Temp:
Power:
Alarm:
Size:
Approvals:
0-10V, 0-20mA, 4-20mA
±0.015% rng / ±0.05% rng
1800V AC/DC, In/Out/Power
0 to 60°C, <95% RH
9-30VDC, 1W typ.
2 SPDT, [email protected]
0.5" wide DIN rail case
UL508, CSA C22.2, CE
ORDERING INFORMATION
Model
WV408-2000
Function
DC
Range
±150mV, 1.5/15/150V,
2.5/25mA +reverse
WV418-2000
RTD
2/3/4 wire: Pt100, Cu10
WV428-2000
T/C
J,K,T,R,S,E,B,N,C,B
WV438-2000
Potentiometer
100Ω to 100kΩ
WV448-2000
Bridge
±5/10/20/50/100/200mV
(1-10VDC, 120mA excitation)
WV468-2000
AC
±50/150/500mV,
5/20/50/150/250V,
20/100mA
+reverse (40-400Hz)
WV478-2000
Frequency
0-10kHz (150mV-150V)
WVC16-2000
Communication Up to 32 modules to
Ethernet 10Base-T
C650-2000
Software
Includes serial cable
WV905
Power Supply
24VDC @0.5A
Also available as Limit Alarms with latching relays & reset switch
Pyragon Temperature Transmitter
• T/C Head Mount
• Wide Operating
Temperature Range
• Factory Configured,
Ready to Install
L
2700T
SPECIFICATIONS
Input:
T/C J,K,T,E,R,S,B,N,L,U,W
RTD Pt, Ni, Cu; 2,3 or 4-wire
DC -10 to 70mV, -0.1 to 1.1V
Resistance 390Ω, 2200Ω
Input Accuracy: 0.1°C (Pt100), 1°C (K T/C)
Output:
2-wire, 4-20mA or 20-4mA
Output Accuracy: 0.1% of span
Resolution:
Input 16 bit, Output 12 bit
Supply:
8-35VDC
Operating Temp: -40 to 85°C, <98% RH condensing
Dimensions:
1.73" dia x 1.04" (44x26.3mm)
Isolation:
3.75kV AC
ORDERING INFORMATION
PY/2700T
PY/2750T
Temperature Transmitter (specify input type & range)
2700T with Hart® protocol
NLS Series 8000 Signal Conditioners
L
• Input, Output, Isolation, Power Supply and Special Functions Combined into One Low Cost Modular Unit
• Field-Settable Range and Span and Field Configuration
• Fuse Protected Linear Power
• UL Recognized
8000-1-1
• High Impact, Flame Retardant Polycarbonate Case
The Series 8000 signal conditioners are designed with a modular architecture to allow full input, output,
and special function selectability and interchangeability. They can also be used as isolators, signal amplifiers, and transmitters.
85
NLS Series 8000 Signal Conditioners
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: 8000-1-1-01(0-27.2V)-60(4-20mADC)
A – B – C – D – E
A
B
C
Basic and Power—See Base Style Selection Chart
8000-1-1
8–Pin, 120 VAC Power
8000-2-1
11–Pin, 120 VAC Power
8000-3-1
20–Pin, 120 VAC Power
8000-2-2
11–Pin, 240 VAC Power
8000-3-2
20–Pin, 240 VAC Power
8000-1-3
8–Pin, 9–30 VDC Power
8000-2-3
11–Pin, 9–30 VDC Power
8000-3-3
20–Pin, 9–30 VDC Power
Input Code
01
DC: Voltage to 300, Current to 100 mA— Specify Range
02 Potentiometer: Any Value from 0–100Ω to 100 kΩ
03 AC: Voltage to 250 V, Current to 100 mA— Specify Range
04 Thermocouple: non-linearized J, K, T, E, R, S, or B— Specify Type and range.
See special function "43"for Linearization
05 RTD: Pt100Ω (∝00385), Cu10Ω or Ni120Ω—Specify Type and Range
06 DC Millivolts: 0–200 (8 mV min span)—Specify Range
08 LVDT: 50 mV/V to 800 mV/V RMS—Specify Range
09 Strain Gauge: 2 mV/V to 20 mV/V—Specify Range
10
Frequency: 0–50 kHz (50 Hz min span)—Specify Range
11
Ramp/Soak Programmer
12 High Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
13 Low Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
14
Add/Subtract: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
15 Multiply (A x B)—Specify # of inputs and type
16
Divide (A x B)—Specify # of inputs and type
Output Code
60 DC: 0–12V (100 mV min) or 0–50 mA (1 mA min)—Specify Range
70 Frequency: 5V (TTL), 0–50 kHz (11 pulses/hour min)—Specify Range
71
Frequency: Contact Closure 0–2 Hz (11 pph min)—Specify Range
72 Frequency: 24V pulse 0–50 kHz (11 pph min)—Specify Range
73 Valve Positioner: Pot 100-9.9 kΩ, 10k–100 kΩ;
4–20 mADC, 0–1 VDC or 0–10 VDC—Specify feedback type
80 Single Alarm Setpoint: Single Turn Pot. Screwdriver Adj.
D
E
81
Single Alarm Setpoint: Remote 4–20 mADC
82 Single Alarm Setpoint: Remote 1–5 VDC
83 Single Alarm Setpoint: Remote 0–1 VDC
84 Single Alarm Setpoint: Remote 0–10 VDC
85 Single Alarm Setpoint: Multi-turn Pot., Screwdriver Adj.
86 Single Alarm Setpoint: Plus Top Mounted Knob, 0–100%
87 Single Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ
90 Dual Alarm Setpoint: Single Turn Pot. Screwdriver
91
Dual Alarm Setpoint: Remote 4–20 mADC
92 Dual Alarm Setpoint: Remote 1–5 VDC
93 Dual Alarm Setpoint: Remote 0–1 VDC
94 Dual Alarm Setpoint: Remote 0–10 VDC
95 Dual Alarm Setpoint: Multi-turn Pot., Screwdriver Adj.
96 Dual Alarm Setpoint: Plus Top Mounted Knob, 0–100%
97
Dual Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ
Special Functions
00 None
40 Square Root
41
Power Term: Nth Power
42 Nth Root: Adjustable root 0.5 to 5
43 Thermocouple Linearization (type/range specified by input code)
44 Curve Fit Linearization: Curve or formula must be provided
45 Ramp Buffer: Delays signal action (adj. 1 sec To 20 min)
46 Peak/Valley Sample Hold: Specify Peak or Valley
48 Rate of Change Processor: (Specify time base, 1 sec etc.)
Options for Alarm Setpoints
00 None
01
Low or Low/Low relay sense (Single or dual alarms)
02 High/High relay sense (Dual alarms)
03 Fail-Safe Operation (Dual alarms)
04 Transmitter Output 0–1V output for process, Setpoint #1
and Setpoint #2 (Setpoint output not avail. with strain gage,
add/subtract, or high/low select
05 Latching relay(s): Jumper selectable for Latch/Non-Latch
07
Voltage Output (24V @ 15 mA) replaces relay contacts
Options for Temperature Inputs
06 Down scale burnout for thermocouple input
08 Differential RTD input: Specify differential range
09 Differential thermocouple input: Specify differential range
BASE STYLE SELECTION CHART
Output Code
Type
60
80, 85, 86
90, 95, 96
73, 81, 82, 83,
70
71
60
70, 71
84, 91, 92, 93
72
72 w/46
94; or 80, 85, 86
Input Code
90,95, 96 w/ 07
01/03/04/06/10
DC, AC, Frequency
8
11
20
8
11
11
20
02
Potentiometer
8
20
20
8
20
20
20
05
RTD
20
20
20
8
20
20
20
09
Strain Gauge
11
20
20
11
11
—
—
08
LVDT
11
20
—
20
20
—
—
15/16
Multiply/Divide
8
20
20
8
20
20
20
12/13/14
High/Low
20
20
20
20
20
—
—
11
Ramp/Soak
20
20
—
—
20
—
—
To determine the number of pins required for the signal conditioner, select input code and output code and read across and down. Make sure to order mounting socket.
ACCESSORIES
Mounting Sockets—Required and Sold Separately
DR011 11–Pin Barrier Terminal Socket for DIN Rail or Flush Mount
DR014 Din Rail—Three Foot Length Metal Channel Track
DR018 8–Pin Barrier Terminal Socket for DIN Rail or Flush Mount
SM004 DIN Rail—Four Foot Length Plastic Channel Track
SM008
SM011
SM020
SX008
8–Pin Barrier Terminal Socket for Channel Track
11–Pin Barrier Terminal Socket for Channel Track
20–Pin Barrier Terminal Socket for Channel Track
Explosion Proof Housing (Meets Class1, Group D,
Class II, Group E, F, and G)
85a
NLS Series 8000 Signal Conditioners
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: 8000-1-1-01(0-27.2V)-60(4-20mADC)
A – B – C – D – E
A
B
C
Basic and Power—See Base Style Selection Chart
8000-1-1
8–Pin, 120 VAC Power
8000-2-1
11–Pin, 120 VAC Power
8000-3-1
20–Pin, 120 VAC Power
8000-2-2
11–Pin, 240 VAC Power
8000-3-2
20–Pin, 240 VAC Power
8000-1-3
8–Pin, 9–30 VDC Power
8000-2-3
11–Pin, 9–30 VDC Power
8000-3-3
20–Pin, 9–30 VDC Power
Input Code
01
DC: Voltage to 300, Current to 100 mA— Specify Range
02 Potentiometer: Any Value from 0–100Ω to 100 kΩ
03 AC: Voltage to 250 V, Current to 100 mA— Specify Range
04 Thermocouple: non-linearized J, K, T, E, R, S, or B— Specify Type and range.
See special function "43"for Linearization
05 RTD: Pt100Ω (∝00385), Cu10Ω or Ni120Ω—Specify Type and Range
06 DC Millivolts: 0–200 (8 mV min span)—Specify Range
08 LVDT: 50 mV/V to 800 mV/V RMS—Specify Range
09 Strain Gauge: 2 mV/V to 20 mV/V—Specify Range
10
Frequency: 0–50 kHz (50 Hz min span)—Specify Range
11
Ramp/Soak Programmer
12 High Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
13 Low Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
14
Add/Subtract: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
15 Multiply (A x B)—Specify # of inputs and type
16
Divide (A x B)—Specify # of inputs and type
Output Code
60 DC: 0–12V (100 mV min) or 0–50 mA (1 mA min)—Specify Range
70 Frequency: 5V (TTL), 0–50 kHz (11 pulses/hour min)—Specify Range
71
Frequency: Contact Closure 0–2 Hz (11 pph min)—Specify Range
72 Frequency: 24V pulse 0–50 kHz (11 pph min)—Specify Range
73 Valve Positioner: Pot 100-9.9 kΩ, 10k–100 kΩ;
4–20 mADC, 0–1 VDC or 0–10 VDC—Specify feedback type
80 Single Alarm Setpoint: Single Turn Pot. Screwdriver Adj.
D
E
81
Single Alarm Setpoint: Remote 4–20 mADC
82 Single Alarm Setpoint: Remote 1–5 VDC
83 Single Alarm Setpoint: Remote 0–1 VDC
84 Single Alarm Setpoint: Remote 0–10 VDC
85 Single Alarm Setpoint: Multi-turn Pot., Screwdriver Adj.
86 Single Alarm Setpoint: Plus Top Mounted Knob, 0–100%
87 Single Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ
90 Dual Alarm Setpoint: Single Turn Pot. Screwdriver
91
Dual Alarm Setpoint: Remote 4–20 mADC
92 Dual Alarm Setpoint: Remote 1–5 VDC
93 Dual Alarm Setpoint: Remote 0–1 VDC
94 Dual Alarm Setpoint: Remote 0–10 VDC
95 Dual Alarm Setpoint: Multi-turn Pot., Screwdriver Adj.
96 Dual Alarm Setpoint: Plus Top Mounted Knob, 0–100%
97
Dual Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ
Special Functions
00 None
40 Square Root
41
Power Term: Nth Power
42 Nth Root: Adjustable root 0.5 to 5
43 Thermocouple Linearization (type/range specified by input code)
44 Curve Fit Linearization: Curve or formula must be provided
45 Ramp Buffer: Delays signal action (adj. 1 sec To 20 min)
46 Peak/Valley Sample Hold: Specify Peak or Valley
48 Rate of Change Processor: (Specify time base, 1 sec etc.)
Options for Alarm Setpoints
00 None
01 Low or Low/Low relay sense (Single or dual alarms)
02 High/High relay sense (Dual alarms)
03 Fail-Safe Operation (Dual alarms)
04 Transmitter Output 0–1V output for process, Setpoint #1
and Setpoint #2 (Setpoint output not avail. with strain gage,
add/subtract, or high/low select
05 Latching relay(s): Jumper selectable for Latch/Non-Latch
07
Voltage Output (24V @ 15 mA) replaces relay contacts
Options for Temperature Inputs
06 Down scale burnout for thermocouple input
08 Differential RTD input: Specify differential range
09 Differential thermocouple input: Specify differential range
BASE STYLE SELECTION CHART
Output Code
Type
60
80, 85, 86
90, 95, 96
73, 81, 82, 83,
70
71
60
70, 71
84, 91, 92, 93
72
72 w/46
94; or 80, 85, 86
Input Code
90,95, 96 w/ 07
01/03/04/06/10
DC, AC, Frequency
8
11
20
8
11
11
20
02
Potentiometer
8
20
20
8
20
20
20
05
RTD
20
20
20
8
20
20
20
09
Strain Gauge
11
20
20
11
11
—
—
08
LVDT
11
20
—
20
20
—
—
15/16
Multiply/Divide
8
20
20
8
20
20
20
12/13/14
High/Low
20
20
20
20
20
—
—
11
Ramp/Soak
20
20
—
—
20
—
—
To determine the number of pins required for the signal conditioner, select input code and output code and read across and down. Make sure to order mounting socket.
ACCESSORIES
Mounting Sockets—Required and Sold Separately
DR011 11–Pin Barrier Terminal Socket for DIN Rail or Flush Mount
DR014 Din Rail—Three Foot Length Metal Channel Track
DR018 8–Pin Barrier Terminal Socket for DIN Rail or Flush Mount
SM004 DIN Rail—Four Foot Length Plastic Channel Track
SM008
SM011
SM020
SX008
8–Pin Barrier Terminal Socket for Channel Track
11–Pin Barrier Terminal Socket for Channel Track
20–Pin Barrier Terminal Socket for Channel Track
Explosion Proof Housing (Meets Class1, Group D,
Class II, Group E, F, and G)
85a
Pyragon Loop Isolator
• Signal Powered CMOS Circuitry
• Precise Duplication of Input Signals
• 4–20 or 10–50 mA, Same Unit
• High Common Mode Rejection
• 1500 VRMS Isolation
• Mounts on Bulkhead or in 3" Conduit Box
Provides the Necessary Signal Isolation
for Noisy Process Circuits
If your process signals are influenced by
ground loops, high common mode noise, or
other interference, you need the Transmation
Model 10 Auto-Isolator. Requiring no separate
power supply, Auto-Isolator operates efficiently
from input signal current, and precisely
retransmits the current applied to the input
with an accuracy of ±0.1% of span.
Usable with milliamp signal ranges of 4–20,
10–50, or other ranges between 4 and 50 mA.
The instrument can be bulkhead-mounted
or installed in a 3-inch cast conduit box.
A trim potentiometer, accessible through
the instrument’s top plate, permits precise
adjustment of current transfer as a function
of load resistance up to 500 ohms at 20 mA,
and 250 ohms at 50 mA.
10AI
L
SPECIFICATIONS
Input:
Output Ratings:
ORDERING INFORMATION
10AI
10AI-EXP
Model 10 Auto-Isolator
Model 10 in Explosion Proof Housing
SIGNAL
CONDITIONERS
Accuracy:
Size/Weight:
4–20 mA, 10–50 mA, or other spans within range of 4–50 mA
4–20 mA with loads from 0–500 ohms
10–50 mA with loads from 0–250 ohms
±0.1% of span
2.95" diameter, 1.88" high/6 oz
Pyragon Universal Temperature Transmitters
• Configurable for Eight T/Cs, 12 RTDs, Millivolts, Ohms
• Unmatched Programmability: Input Type, Range, Zero, Span, Linear Output, Engineering
Units; Calibration Runs
• Exceptionally Economical: Reduces Inventory and Maintenance Costs
• Built for Reliability: RFI Protected, Isolated, Environmentally Tough, Five-Year Warranty
SPECIFICATIONS
Input Types
Thermocouple:
RTD:
2800T
L
Types J, K, T, E, R, S, N, B
Pt DIN 43760 (50, 100, 200, 500Ω); Pt JIS C 1604 (100Ω);
Pt Burns 0.003902α (100, 200, 500Ω); Ni Bristol’s 7NA
(110Ω); Ni Minco (120Ω); Cu Minco (10Ω); Cu China
0.00428α (50Ω)
mV:
-100 to + 100 mV
Resistance:
0 to 1000Ω
Accuracy:
±0.05% of span ±1 digit
Input Span Limits:
Any span within range limits
Input Resolution:
0.1°, 1 µV, 0.005Ω
Output Range:
4 to 20 mA, calibrated; 3.7 to 22 mA, maximum
Output Resolution:
0.002 mA
RTD Excitation Current: 200 µA, typical
Temperature Effect
T/C and mV:
±0.2 µV/°C max ±0.005% of input reading/°C
RTD and Ω:
±0.002 Ω/°C max ±0.005% of input reading/°C
Loop Supply Voltage:
13V + (load resistance x 20 mA), min; 48V, max
Size
3.10 x 1.75 x 3.77" HWD
ORDERING INFORMATION
2800T
2800T-EXP
2850T
100665-651
100665-652
Universal Temperature Transmitter,
Digital Display (NI FM Approved)
2800T in Explosion Proof Housing
2800T with HART Protocol
32 mm DIN Rail Adaptor—2800T
35 mm DIN Rail Adaptor—2800T
86
Distributed by:
WESCHLER INSTRUMENTS
800--903--9870
440--238--2550
www.weschler.com
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
fax 800--903--9590
440--238--0660
[email protected]
www.redlion.net
MODEL IAMS – INTELLIGENT UNIVERSAL SIGNAL
CONDITIONING MODULE
 UNIVERSAL INPUT, PROCESS, mA DC, VDC, TC, 100 (RTD,
POTENTIOMETER, AND LINEAR RESISTANCE
 UNIVERSAL POWER SUPPLY, 21.6 to 253 VAC/ 19.2 to 300 VDC
 3-WAY ISOLATION (POWER/SIGNAL/OUTPUT)
 CHOOSE SETPOINTS AND/OR ANALOG OUTPUT MODELS
 PROGRAMMING/DISPLAY MODULE (NOT INCLUDED)
 PROGRAMMING AVAILABLE IN SEVEN DIFFERENT
LANGUAGES
FM
APPROVED
IAMS0001
IAMS with
PGMMOD00
C
IAMS0010
GENERAL DESCRIPTION
The IAMS — Universal Signal Conditioners unmatched capability provides
users the ultimate in flexibility. As a signal conditioner, the unit provides
complete isolation and conversion capability to satisfy almost any application.
The Universal Input accepts Process, DC Current, DC Voltage, Thermocouples,
RTDs, Potentiometers, and Linear Resistance signals allowing the module to be
connected to most common sensors. The setpoint model allows dual setpoint
control capability through dual Form A relays. The analog model provides a
retransmitted analog signal. A third model provides both analog and control
capability. The power supply is also universal, accepting 21.6 to 253 VAC/ 19.2
to 300 VDC as its power source. Add the optional programming module and the
unit is easily programmed through menu style programming. The module can
also be used to provide a display of the process variable when it is not being used
for programming.
The IAMS features well over 100 combinations of inputs to outputs
configurations. Input specific terminals allow for the various signals and sensors
to be connected to the unit while the input ranges and resolutions are adjusted in
the input programming loop of the unit. The menu style programming allows the
user quick and easy set-up by using the PGMMOD, programming module. The
module is required to program the IAMS. However, if you are using more than
UL
R
US LISTED
IND. CONT. EQ.
51EB
one IAMS, only one programming module is required. The module can store
programming from one unit and load it to a second unit reducing set-up time for
multiple installations. When the programming module is not being used for
programming, it can indicate the input parameters, just like a panel meter.
The unit’s overall full scale accuracy typically exceeds 0.1 % depending on
the range selection and scaling. The microprocessor based design provides ease
of field scaling and the onboard E2PROM stores scaling values for future recall.
All units come factory precalibrated for all input and output ranges. Factory or
custom field scaling can be selected in the Advanced programming loop. The
IAMS can be factory recalibrated in the field if desired.
The unit’s environmental operating temperature range is -20º C to 60º C. DIN
rail mounting saves time and panel space. The units are equipped with mounting
feet to attach to top hat profile rail according to EN50022 – 35 x 7.5 and 35 x 15.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
DIMENSIONS In inches (mm)
ORDERING INFORMATION
DESCRIPTION
PART NUMBER
Intelligent Universal Signal Conditioner with Analog Output
IAMS0001
Intelligent Universal Signal Conditioner w/Dual Setpoints
IAMS0010
Intelligent Universal Signal Conditioner w/Analog Output and
Dual Setpoints
IAMS0011
Programming Display Module (Not Included) *
PGMMOD00
* At least one module is required to program a unit or a series of units.
IAMS GENERAL SPECIFICATIONS
1. DISPLAY: See Display/ Programming Module
2. POWER:
AC Power: 21.6 to 253 VAC, 50/60 Hz
DC Power: 19.2 to 300 VDC,
3. CONSUMPTION: <2.5 W
4. FUSE: 400 mA SB/250 VAC
5. ISOLATION: Between input, supply and outputs - 2.3 kVAC/250 VAC
6. INPUTS:
Current Input:
Programmable Ranges: 0 to 20 and 4 to 20 mA DC
Measurement range: -1 to 25 mA
Input resistance: Nom. 20 Ω + PTC 50 Ω
Sensor error detection: 4 to 20 loop break, yes
Supply Voltage: 16-25 VDC, 20 mA max (Terminal 43 and 44)
Voltage Input:
Programmable Ranges: 0 to 1, 0.2 to 1, 0 to 5, 1 to 5, 1 to 10, and 2 to 10
VDC
Measurement range: -20 mV to 12 VDC
Input resistance: Nom. 10 MΩ
Thermocouple Inputs:
Thermocouple Type: B, E, J, K, L, N, R, S, T, U, W3, W5, and LR
Cold Junction Compensation: via internally mounted sensor < ±1.0 ºC
Sensor Error Detection: All TC types, yes
Sensor Error Current: When detecting 2 µA, otherwise 0 µA
RTD, Linear Resistance, Potentiometer Inputs
RTD Types: Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500,
Pt1000, Ni50, Ni100, Ni120, and Ni1000
INPUT TYPE
MIN. VALUE
MAX. VALUE
Pt100
-200 °C
+850 °C
STANDARD
IEC60751
Ni100
-60 °C
+250 °C
DIN 43760
Lin. R
0Ω
10000 Ω
-
Potentiometer
10 Ω
100 kΩ
-
Cable Resistance per wire: RTD, 50 Ω max.
Sensor Current: RTD, Nom. 0.2 mA
Sensor Error Detection: RTD, yes
Short Circuit Detection: RTD, < 15 Ω
7. STEP RESPONSE TIME: (0 to 90% or 100 to 10%)
Temperature input: ≤ 1 sec
Current/Voltage input: ≤ 400 msec
8. ACCURACY: The greater of the general and basic values.
GENERAL VALUES
Input Type
Absolute Accuracy
Temperature Coefficient
All
≤ ±0.1% of span
≤ ±0.1% of span/°C
Input Type
Basic Accuracy
Temperature Coefficient
BASIC VALUES
mA
≤ ±4 µA
≤ ±0.4 µA/°C
Volt
≤ ±20 µV
≤ ±2 µV/°C
Pt100
≤ ±0.2 °C
≤ ±0.01 °C/°C
Lin. R
≤ ±0.1 Ω
≤ ±0.01 Ω/°C
Potentiometer
≤ ±0.1 Ω
≤ ±0.01 Ω/°C
TC Type:
E, J, K, L, N, T, U
≤ ±1 °C
≤ ±0.5 °C/°C
TC Type: B, R, S,
W3, W5, LR
≤ ±2 °C
≤ ±0.2 °C/°C
9. CALIBRATION TEMPERATURE: 20 to 28 ºC
10. RELAY OUTPUTS: Dual Form A. Contacts rated at 2 A AC or 1 A DC
Hysteresis: 0.1 to 25 % (1 to 2999 display counts)
On and off delay: 0 to 3600 sec
Sensor Error Detection: Break / Make / Hold
Max. Voltage: 250 Vrms
Max. Current: 2 A AC or 1 ADC
Max. Power: 500 VA
Authorized Distributor:
TYPE
MIN. VALUE
MAX. VALUE
STANDARD
B
+400 °C
+1820 °C
IEC 60584-1
E
-100 °C
+1000 °C
IEC 60584-1
J
-100 °C
+1200 °C
IEC 60584-1
K
-180 °C
+1372 °C
IEC 60584-1
L
-200 °C
+900 °C
DIN 43710
N
-180 °C
+1300 °C
IEC 60584-1
R
-50 °C
+1760 °C
IEC 60584-1
S
-50 °C
+1760 °C
IEC 60584-1
T
-200 °C
+400 °C
IEC 60584-1
U
-200 °C
+600 °C
DIN 43710
W3
0 °C
+2300 °C
ASTM E988-90
W5
0 °C
+2300 °C
ASTM E988-90
LR
-200 °C
+800 °C
GOST 3044-84
11. ANALOG OUTPUT:
Current Output:
Signal Range (Span): 0 to 20 mA
Programmable Measurement Range: 0 to 20, 4 to 20, 20 to 0, and 20 to 4
mA
Load Resistance: 800 Ω max.
Output Compliance: 16 VDC max.
Load Stability: = 0.01 % of span, 100 Ω load
Sensor Error Detection: 0 / 3.5 mA/ 23 mA / none
Output Limitation: For 4 to 20 and 20 to 4 mA signals - 3.8 to 20.5 mA
For 0 to 20 and 20 to 0 mA signals - 0 to 20.5 mA
Current Limit: = 28 mA
Voltage Output:
Signal Range: 0 to 10 VDC
Programmable Signal Ranges: 0 to 1, 0.2 to 1, 0 to 10, 0 to 5, 1 to 5, 2 to
10, 1 to 0, 1 to 0.2, 5 to 0, 5 to 1, 10 to 0, and 10 to 2 V
Load: 500 K Ω min
12. ENVIRONMENTAL CONDITIONS:
Operating Temperature: -20 to +60 ºC
Operating and Storage Humidity: 95% relative humidity (non-condensing)
13. CERTIFICATIONS AND COMPLIANCES:
ELECTROMAGNETIC COMPATIBILITY:
EMC 2004/108/EC Emission and Immunity EN 61326
EMC Immunity Influence
<± 0.5% of span
Extended EMC Immunity: NAMUR NE 21,
A criterion, burst
<± 1% of span
SAFETY
LVD 2006/95/EC
EN 61010-1
Factory Mutual Approved, Report #3034432, FM 3600, 3611, 3810, and
ISA 82.02.01
FM, applicable in: Class I, Div. 2, Group A, B, C, D
Class I, Div. 2, Group IIC
Zone 2
Max. ambient temperature for T5
60°C
UL Listed, File # E324843, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Refer to the EMC Installation Guidelines section of this bulletin for
additional information.
14. CONSTRUCTION: IP 50/IP20 Touch Safe, case body is black high impact
plastic. Pollution Degree 1.
15. CONNECTIONS: High compression cage-clamp terminal block. Use
60/75°C copper conductors only.
Wire strip length: 0.3" (7.5 mm)
Wire gage: 26 – 14 AWG stranded wire
Torque: 4.5 inch-lbs (0.5 N-m) max
16. WEIGHT: 5 oz (145 g)
5.6 oz (160 g) with programming module
WESCHLER INSTRUMENTS 800-903-9870 www.weschler.com [email protected]
Selco Signal Conditioners
Programmable Transmitter
Signal Isolators
• Change Input and Output Range
by Front DIP Switches
• Small Size
• AC or DC Power
• AC or DC Powered (TH)
Self-powered (TZ)
• Selectable Filter 50/500msec
• Normal or Reverse Output
• Easy Connection
• DIN Rail Mount
• DIN Rail Mount
L
TH-2X
TW-4M
SIGNAL
CONDITIONERS
SPECIFICATIONS
Basic Accuracy:
Linearity:
Temperature coefficient:
Response time:
Insulation resistance:
Dielectric strength:
Power supply:
Power consumption:
Operating temperature:
Maximum input:
Dimensions (mm):
Connections:
Input Range
0 to 5 VDC
0 to 10 VDC
0 to 60 mVDC
1 to 5 VDC
-5 to +5 VDC
-10 to +10 VDC
4 to 20 mADC
0 to 20 mADC
Output Range
0 to 5 VDC
1 to 5 VDC
-5 to +5 VDC
0 to 10 VDC
-10 to +10 VDC
4 to 20 mADC
0 to 20 mADC
±0.25% FS
Less than ±0.1% of full scale
±0.02% FS/°C
<50ms (0 to 90%) with filter off
>100MΩ at 500VDC, between input and
output or power supply
1 min. at 2000VAC, between input and
output or power supply
24VDC ±10%
100-240VAC ±10%
<80mA (at 24VDC)
<50mA (at 100-240VAC)
-5 to 50°C, <95% RH (non-condensing)
-50 to +150% of range
48 W x 98 H x 41 D
M3.5 screw terminals
Input Resistance
>1MΩ
250Ω
Allowable Load Resistance
>2kΩ
>4kΩ
<550Ω
ORDERING INFORMATION
SE/TW-4M-1-N Programmable Transmitter, 100-240 VAC Power
SE/TW-4M-4-N Programmable Transmitter, 24VDC Power
SE/TZ-41
Signal Isolator, Self powered
SE/TH-2X-**L Signal Isolator, AC powered (insert input/output codes)
SE/TH-5X-**L Signal Isolator, DC powered (insert input/output codes)
Example: SE/TH-5X-42L for 0-1V in and 0-10V out
83
L
TZ-41
L
TZ-41 SPECIFICATIONS
Signal input:
Signal output:
Input current:
Load:
Voltage loss:
Output ripple:
Temperature coefficient:
Accuracy:
Additional error:
Operating temperature:
Insulation resistance:
Dielectric strength:
Dimensions (mm):
0 to 20mA, 4 to 20mA, 0 to 5mA
Same as signal input (1:1 ratio)
Max. 30mA
Max. 1000Ω
Approx. 3.3V between input and output
<0.5% (20mA at 250W)
Less than ±100PPM/°C
±0.1% (23 ±1°C) at 250W load
+0.1%/100Ω at load <250Ω
-0.1%/100Ω at load >250Ω & <600Ω
-5 to +50°C, less than 90% RH
>100MΩ at 500VDC (input to output)
1 min. at 2kVAC (input to output)
25 W x 98 H x 41 D
TZ-41 will also provide 0 to 5V or 1 to 5V output.
TH-2X & TH-5X SPECIFICATIONS
Basic Accuracy:
Load/supply variation:
Temperature coefficient:
Response time:
Input resistance:
Insulation resistance:
±0.1% of full scale
±0.06% of full scale each
±0.02% FS/°C
<50ms (0 to 90%)
>1MΩ on VDC, 250Ω on mADC
>100MΩ at 500VDC, between input and
output or power supply
Dielectric strength:
1 min. at 1500VAC, between input and
output or power supply
Power supply:
24VDC ±10%
100-240VAC ±10%
Power consumption:
<50mA @ 24VDC, <20mA @ 100VAC
Operating temperature:
-5 to 50°C, <90% RH (non-condensing)
Maximum input:
-50 to +150% of range
Dimensions (mm):
13 W x 99 H x 115 D
In p u t C o d e
Rang e
In p u t C o d e
Rang e
0
0 to 5 VDC
6
0 to 60 mVDC
1
1 to 5 VDC
7
0 to 20 VDC
2
0 to 10 VDC
8
-2 to +2 VDC
3
-10 to +10 VDC
9
-5 to +5 VDC
4
0 to 1 VDC
A
4 to 20 mADC
5
0 to 100 mVDC
B
0 to 20 mADC
O u t p u t C o d e Rang e
0
0 to 5 VDC
1
1 to 5 VDC
2
0 to 10 VDC
3
-10 to +10 VDC
A
4 to 20 mADC
Allo wable Load
>2kΩ
>4kΩ for posivite output,
>10kΩ for negative output
<550Ω
NEW
Selco Transmitters
INPUT RANGES
• Miniature Size
Input Type XA - DC Volts/mA
• Variety of Input Types
• 1500V Isolation
• AC or DC Powered
• DIN Rail Mounting
TZ-1XA
SPECIFICATIONS
Basic Accuracy:
Load/supply variation:
Temperature coefficient:
Response time:
Front adjustments:
Insulation resistance:
Dielectric strength:
Power supply:
Operating temperature:
Case material:
Dimensions (mm):
±0.1% of full scale, except
±0.2% of full scale on CA, DA & EA types
±0.06% of full scale each
±0.02% FS/°C
<50ms (0 to 90%) except 500ms on CA type,
700ms on DA & EA types
±5% for zero & span
>100MΩ at 500VDC, between input and
output or power supply
1 min. at 1500VAC, between input and
output or power supply
24VDC ±10%
100-240VAC ±10%
-5 to 50°C, <90% RH (non-condensing)
Black ABS, 94V-2
25 W x 99 H x 41 D
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: TZ-1XA-22L
A
A
B
C
D
E
B
_
C
D
E
Basic Unit
TZ-1
Transmitter, 100-240 VAC powered
TZ-5
Transmitter, 24 VDC powered
Input Type
XA
DC Volts/mA
FA
DC mV/μA
EA
AC Volts (TRMS, AC coupled, 40-1000Hz)
DA
AC Amps (TRMS, CT coupled, 40-1000Hz)
AA
RTD (Pt100, 3-wire, α=385)
CA
Thermocouple (J, K, R, S or T)
BA
Potentiometer
LA
mA loop (TZ-5 only)
Input Range
Select code from input table for type specified above
Output Range
Allowable Load
0
0 to 5 VDC
>2kΩ
1
1 to 5 VDC
2
0 to 10 VDC
>4kΩ for positive output,
3
-10 to +10 VDC
>10kΩ for negative output
4
-2 to +2 VDC
>2kΩ for positive output,
5
-2.5 to +2.5 VDC
>10kΩ for negative output
6
-5 to +5 VDC
7
0 to 4 VDC
>2kΩ
A
4 to 20 mADC
<550Ω
B
0 to 20 mADC
Response Time (XA & FA types only)
L
Normal (50 msec)
H
Fast (1 msec on type XA, 3msec on type FA)
Code
0
1
2
3
4
5
6
7
8
9
A
B
Range
0 to 5 VDC
1 to 5 VDC
0 to 10 VDC
-10 to +10 VDC
0 to 1 VDC
0 to 100 mVDC
0 to 60 mVDC
0 to 20 VDC
-2 to +2 VDC
-5 to +5 VDC
4 to 20 mADC
0 to 20 mADC
Input Resistance
>1MΩ
Maximum Input
-50 to +150%
of full scale
250Ω
Input Type FA - DC mV/ μA
Code
0
1
2
3
4
A
B
C
Range
0 to 5 mVDC
0 to 10 mVDC
0 to 50 mVDC
0 to 60 mVDC
0 to 100 mVDC
0 to 10 μADC
0 to 100 μADC
0 to 200 μADC
Input Resistance
>1MΩ
Maximum Input
-50 to +150%
of full scale
1kΩ
500Ω
Input Type EA - AC Volts
Code
1
2
3
4
5
Range
0 to 35 VAC
0 to 100 VAC
0 to 110 VAC
0 to 200 VAC
0 to 220 VAC
Input Resistance
>200kΩ
>1MΩ
Maximum Input
150%
of full scale
or 300VAC
Input Type DA - AC Amps
Code
1
2
Range
0 to 1 AAC
0 to 5 AAC
Input Resistance
<0.05Ω
Maximum Input
7.5 AAC
Input Type AA - RTD
Code
0
1
2
3
4
Range
-50 to +50 °C
0 to 100 °C
0 to 200 °C
0 to 300 °C
-20 to +80 °C
Input Resistance
Maximum Input
Pt100 (3-wire)
-50% to 150%
of full scale
Input Type CA - Thermocouple
Code
J0
K2
K3
K4
K5
R0
S0
T0
T1
TC
J
K
K
K
K
R
S
T
T
Range
0 to 1000 °C
-50 to +200 °C
0 to 200 °C
-50 to +1200 °C
0 to 1200 °C
0 to 1700 °C
0 to 1700 °C
-50 to +350 °C
0 to 350 °C
Input Res.
>1MΩ
Max. Input
±150%
Input Type BA - Potentiometer
Code
1
Range
0 to 100%
Input Resistance
100Ω to 10kΩ
Input Type LA - mA loop
Code
A
Range
4 to 20 mADC
Input Resistance
250Ω
Custom ranges for any input type are available on special order.
82a
Weschler Process Loop Splitter
• Three Separate 4 mA to 20 mA Outputs
• DIN Rail Mounting
• Screw Terminal Connections
• Low Input Resistance
• Flexible and Simple Scaling
• Excitation Output
• Wide Power Supply Range
• Narrower Case than Previous Model
SIGNAL
CONDITIONERS
SPECIFICATIONS
Input
Input Signal:
Input Resistance:
Excitation Voltage:
Output
Number of Outputs:
Output Range:
Adjustability:
Accuracy:
Speed of Response:
Isolation:
Drive Capacity:
Power Consumption:
Operating Temperature:
Size (mm):
Mounting:
Sealing:
The TIM-018 allows one 4 to 20 mA
signal to be split into three separate
loops. Each output has its own zero
and span adjustments, which are
accessible from the front panel.
4 mA–20 mA, 0–10 mA
50Ω
20 VDC nominal, 28mA max
3
4 mA–20 mA, 0–10 mA
Zero ±1 mA, span ±9 mA
±0.1% of span
200 milliseconds
380V to earth and power
600Ω per loop
3W max
0–50°C, <90% RH non-condensing
22.5 W x 99 H x 111 D
DIN rail EN50 022
IP40
All loops are load isolated so an open
or short on one loop will not affect the
other loops. An internal 20V supply
provides sensor excitation.
L
Note: All loop + terminals are
internally connected.
TIM018-Mk2
ORDERING INFORMATION
TIM018-Mk2-AC
TIM018-Mk2-DC
Process Loop Splitter for 95-265VAC operation
Process Loop Splitter for 11-30VDC operation
Pyragon Universal Process I/O Module
•
•
•
•
•
Direct Replacement for Transmation 3000 Series Modules
Universal Input Includes TC, RTD, mADC, mVDC
4 Digit Alpha-Numeric LED Display
Input Isolated from Output and Power
4 Year Warranty
ORDERING INFORMATION
Alarm/Transmitter in Metal Case
Alarm/Transmitter w/o case
Transmitter Only
L
P3100
P3100-WOC
P3100T
The P3100 accepts a wide variety of
inputs. The 4 digit display provides a
local readout. Use the P3100 in a new
installation or to replace existing
3000 series units.
P3100
SPECIFICATIONS
Models Replaced:
3510A, 3520A, 3530A, 3540A, 3610A, 3620A, 3630A,
3640A, 3650A, 3660A, 3510DRA, 3520DRA, 3530DRA, 3540DRA,
3610DRA, 3620DRA, 3630DRA, 3640DRA, 3650DRA, 3660DRA,
3510T, 3530T, 3610T, 3630T, 3650T, 3900F, 3909F
Input Types
J, K, T, E, R, S, B, L, U, N
Thermocouple:
RTD (2 or 3 wires):
100Ω Pt (α.00385, .00392, .003916);
200, 500 & 1000Ω Pt (α.00385);
120Ω Ni and 10Ω Cu
Current:
±20 & ±50mA DC ranges
Voltage:
±1 & ±10V DC ranges
Millivolts:
±70mV
Potentiometer (3 wire) & Resistance (2 wire): 50, 200 & 2000 ranges
Frequency:
Counts/minute, Hz & kHz ranges
87
4-20mA DC (600Ω Load) or 1-5V DC,
10-50mA DC optional
LED Display:
4-Digit Alphanumeric, Decimal Point configurable
for 0, 1st, 2nd or 3rd place
Front Panel Buttons:
Relay Trip & Recovery parameters,
Relay states override, Latch reset and output manual mode
Analog Accuracy:
0.1% of Span or 10mV referred to input
Loop Power:
24VDC supply to power input mA signals up to 21mA
DPDT Relay:
Configurable delay & latching
Working Voltage:
300VAC Input to Output to Input Power
Isolation:
1000VDC Input to Output to Input Power
Configuration Interface:
RS232, 1200 baud, ASCII half duplex
Operating Temperature:
0-50°C
Power (jumper selectable):
100–240VAC, 50/60Hz and 24VDC ±10%
Signal Output: