AXIS T90A 2x/3x/4x Installation Guide AXIS T90A 2x/3x/4x

MAX and
LUX
illuminators installation guide
(including IR Covert, IR PLATINUM, HYBRID and Low Voltage Series)
This installation guide provides instructions for installing the RAYMAX
and RAYLUX series illuminators
Installation Steps
1. Mount Illuminator
2. Mount Power Supply Unit (PSU)
3. Connect Illuminator to PSU
4. PSU connections
5. Connect PSU to Mains
Overview
Set Up Steps
1. Position illuminator adjacent to
camera and point towards scene
2. Adjust vertical angle
3. Adjust horizontal angle via Adaptive
Illumination (AI) (if required)
4. Tighten all fixings
Package Contents
1.Illuminator
2. Power Supply (PSU)
RAYMAX / RAYLUX illuminator
Version 5.0
Golden Rules:
1.Ensure PSU lid orientation has
warning label in line with glands
(see PSU diagram, right)
2.Ensure operating voltage is
correct for unit being installed
3.DO NOT INPUT MAINS VOLTAGE
INTO LOW VOLTAGE PSU
4. Ensure PSU is fully water tight
g
nin
!
r
wa
PSU
Adaptive illumination bolt
LED illuminator
Bracket
LED output cable x2
2.5m (8.2ft)
Photocell
(automatic operation)
LED output 1
LED output 2
Mains input
!
1.5m
Isolate mains before
removing cover
2
Mount PSU to
flat surface
Install in a well
ventilated area
Do not continually
stare at lamp
Specifications subject to change without notice. Installation to be carried out by suitable trained and qualified personnel.
Installation
1m (3.3ft - 29m
9.5ft)
Model d
Contac ependent
t Rayte
c
1 Mount illuminator
1
2 Mount PSU:
2
Mains Lead
3
Do not position PSU
photocell facing illuminator
or other direct light sources
Photocell monitors ambient
lighting conditions
Mount PSU on wall/flat
surface with glands
facing down
3 Connect Illuminator to PSU:
! CAUTION:Red = +ve
Black = -ve
(polarity sensitive)
Installers can extend or
reduce lead length using
appropriate cable and
weather proof box
!
LED Output x2
Mains In
Telemetry Input
4 PSU connections.
Connect telemetry (if required)
5 Connect PSU to Mains
! CAUTION:Ensure cable glands
and PSU lid are water tight by
tightening the fixings
3
Set Up
TARGET
1 Position illuminator adjacent to
camera and point towards scene
(Optional night set-up for
optimum image performance)
2 Adjust vertical angle
!
Max x2
3 Adjust horizontal angle via Adaptive
4 Tighten all fixings
Illumination (AI) (if required)
! CAUTION: Do not fully loosen AI bolt.
Note: Power adjust available if required (see PSU diagrams, pages 8-9)
Match illumination to camera field of view
x
Camera
x
Light
Camera
Light
Camera
Light
Reduces performance
4
May cause hot spots
Best performance
Technical Drawings (Not to scale)
Standard Bracketry
8.5mm
(0.3”)
100mm
(4”)
48mm
(1.9”)
25mm
(1”)
23.5mm
(0.9”)
47mm
(1.9”)
RM/RL 25
115mm
(4.5”)
8.5mm
(0.3”)
36mm
(1.4”)
72mm
(2.8”)
52mm
(2”)
RM/RL 200/150/100/50
140mm
(5.5”)
33mm
(1.2”)
8.5mm
(0.3”)
RM/RL 300
Optional Bracketry
Wall Mount
Ptz Mount
Dome Mount
Pole Mount
5
PSU Specifications
Infra-Red Series PSU
RM300
RM200
RM150
RM100
RM50
RM25
Input
AC 100-230
universal<120W
AC 100-230
universal<80W
AC 100-230
universal<60W
AC 100-230
universal<40W
AC 100-230
universal<20W
AC 100-230
universal<10W
Fuse
2.5A anti-surge
2.5A anti-surge
2.5A anti-surge
2.5A anti-surge
1A anti-surge
1A anti-surge
Typical Output
(Standard)
6.6A @ 13.5V
4.4A @ 13.5V
3.6A @ 13.5V
2.4A @ 13.5V
1A @ 13.5V
0.5A @ 13.5V
Typical Output
(IR PLATINUM)
9A @ 14V
6A @ 14V
6A @ 14V
4A @ 14V
2A @ 14V
1A @ 14V
Typical
Output
(IR Covert)
9A @ 14V
6A @ 14V
6A @ 14V
4A @ 14V
2A @ 14V
1A @ 14V
Adjustable
Power
10% - 100%
10% - 100%
10% - 100%
10% - 100%
10% - 100%
10% - 100%
Weight
2.3 kg
(5.1lbs)
1.85 kg
(4.1lbs)
2.3 kg
(5.1lbs)
1.65 kg
(3.6lbs)
0.9 kg
(2lbs)
0.8 kg
(1.8lbs)
Dimensions
LxWxD
240 x 160 x 81mm 160 x 160 x 81mm 240 x 160 x 81mm 160 x 160 x 81mm 130 x 130 x 60mm 130 x 130 x 60mm
(9.4 x 6.3 x 3.2”) (6.3 x 6.3 x 3.2”) (9.4 x 6.3 x 3.2”) (6.3 x 6.3 x 3.2”) (5.1 x 5.1 x 2.4”) (5.1 x 5.1 x 2.4”)
4 x M4 holes
@ 225 x 123mm
(8.9” x 4.8”)
Drilling
Dimensions
4 x M4 holes
@ 145 x 123mm
(5.7” x 4.8”)
White-Light Series PSU
4 x M4 holes
@ 145 x 123mm
(5.7” x 4.8”)
4 x M4 holes
@ 113 x 113mm
(4.4” x 4.4”)
4 x M4 holes
@ 113 x 113mm
(4.4” x 4.4”)
RL300
RL200
RL150
RL100
RL50
RL25
Input
AC 100-230
universal<120W
AC 100-230
universal < 80W
AC 100-230
universal<60W
AC 100-230
universal <40W
AC 100-230
universal <20W
AC 100-230
universal <10W
Fuse
2.5A anti-surge
2.5A anti-surge
2.5A anti-surge
2.5A anti-surge
1A anti-surge
1A anti-surge
Typical Output
6.3A @ 13.5V
4.2A @ 13.5V
4.2A @ 13.5V
2.8A @ 13.5V
1.4A @ 13.5V
0.7A @ 13.5V
Adjustable
Power
10% - 100%
10% - 100%
10% - 100%
10% - 100%
10% - 100%
10% - 100%
Weight
2.3 kg
(5.1lbs)
1.85 kg
(4.1lbs)
2.3 kg
(5.1lbs)
1.65 kg
(3.6lbs)
0.9 kg
(2lbs)
0.8 kg
(1.8lbs)
Dimensions
LxWxD
240 x 160 x 81mm 160 x 160 x 81mm 240 x 160 x 81mm 160 x 160 x 81mm 130 x 130 x 60mm 130 x 130 x 60mm
(9.4 x 6.3 x 3.2”) (6.3 x 6.3 x 3.2”) (9.4 x 6.3 x 3.2”) (6.3 x 6.3 x 3.2”) (5.1 x 5.1 x 2.4”) (5.1 x 5.1 x 2.4”)
Drilling
Dimensions
4 x M4 holes
@ 225 x 123mm
(8.9” x 4.8”)
4 x M4 holes
@ 145 x 123mm
(5.7” x 4.8”)
HYBRID Series PSU
6
4 x M4 holes
@ 225 x 123mm
(8.9” x 4.8”)
4 x M4 holes
@ 225 x 123mm
(8.9” x 4.8”)
4 x M4 holes
@ 145 x 123mm
(5.7” x 4.8”)
4 x M4 holes
@ 113 x 113mm
(4.4” x 4.4”)
4 x M4 holes
@ 113 x 113mm
(4.4” x 4.4”)
Input
Fuse
Typical Output
Adjustable
Power
Weight
Dimensions
LxWxD
Drilling
Dimensions
AC 100-230
universal<120W
2.5A anti-surge
Model
dependent
Contact Raytec
10% - 100%
2.3 kg
(5.1lbs)
240 x 160 x 81mm
(9.4 x 6.3 x 3.2”)
4 x M4 holes
@ 225 x 123mm
(8.9” x 4.8”)
Low Voltage PSU (LVP) Specification
Infra-Red and WHITE-LIGHT Series PSU
(Excluding Platinum and Covert Series)
300
200
150
100
50
25
Input
x
24V AC/DC
x
24V AC/DC
12/24V AC/DC
12/24V AC/DC
Fuse
x
5A
x
5A
3A
3A
Typical Output
(Infra-Red)
x
4.4A @ 13.5V
x
2.4A @ 13.5V
1A @ 13.5V
0.5A @ 13.5V
Typical Output
(White-Light)
x
4.2A @ 13.5V
x
2.8A @ 13.5V
1.4A @ 13.5V
0.7A @ 13.5V
Adjustable
Power
x
10% - 100%
x
10% - 100%
10% - 100%
10% - 100%
Weight
x
1.85 kg
(4.1lbs)
x
1.65 kg
(3.6lbs)
0.9 kg
(2lbs)
0.8 kg
(1.8lbs)
Dimensions
LxWxD
x
160 x 160 x 81mm
(6.3 x 6.3 x 3.2”)
x
Drilling
Dimensions
x
4 x M4 holes
@ 145 x 123mm
(5.7” x 4.8”)
x
!
160 x 160 x 81mm 130 x 130 x 60mm 130 x 130 x 60mm
(6.3 x 6.3 x 3.2”) (5.1 x 5.1 x 2.4”) (5.1 x 5.1 x 2.4”)
4 x M4 holes
@ 145 x 123mm
(5.7” x 4.8”)
4 x M4 holes
@ 113 x 113mm
(4.4” x 4.4”)
4 x M4 holes
@ 113 x 113mm
(4.4” x 4.4”)
NOTE: Ensure operating voltage is correct for unit being installed.
DO NOT INPUT MAINS VOLTAGE INTO LOW VOLTAGE PSUs.
Power Supply Features
Standard PSU
PREMIUM PSU-PR
•Adjustable photocell
•Adjustable power
•Telemetry input
•Adjustable photocell
•Adjustable power
•Telemetry input
•Photocell following contact, volt
free relay contact - normally open
(day) to normally closed (night)
•12V DC output @ 1.5A
Pulsed PSU - PU
Premium Timer PSU-PRT
•Analogue version
•TTL version
•No photocell
•Adjustable power
• 12V DC output @ 1.5A
•Synchronised with camera
•Adjustable photocell
•Adjustable power
•Telemetry input
•Photocell following contact, volt
free relay contact - normally open
(day) to normally closed (night)
•12V DC output @ 1.5A
• Timer function
7
Power Supply Diagrams (Not to scale)
Infra-Red and White-Light
RM/RL 50/25 Models
(Not to scale)
Photocell
Power Adjust
LED Output x2
(Polarity Sensitive)
Telemetry Input
- requires zero volt,
latched input
Photocell Sensitivity
Mains Input
100V to 230V AC
Auto-Sensing
Infra-Red and White-Light
RM/RL 200/100 Models (Model shown: RM/RL 100 Premium)
(Not to scale)
12V DC power
output
(Premium PSU only)
Photocell following
contact - volt free,
non polarity sensitive
(Premium PSU only)
Telemetry Input
- requires zero volt,
latched input
Photocell
Power Adjust
LED Output x2
(Polarity Sensitive)
8
Photocell Sensitivity
Mains Input
100V to 230V AC
Auto-Sensing
Infra-Red and White-Light
RM/RL 300/150 and Hybrid Models
(Final specification model dependant - model shown: RM/RL 300 Premium)
Note - Hybrid control boards will be labelled IR/WL
Photocell
following contact
- volt free, non
polarity sensitive
(Premium PSU only)
Telemetry Input
requires zero volt,
latched input
Photocell
Sensitivity
Photocell
12V DC Power
Output (Premium
PSU only)
Power Adjust
Up to x3
LED Output
(Polarity Sensitive)
(Model Dependant)
Mains Input
(100V to 230V AC)
Auto-Sensing
Hybrid PSU Models
Factory Setting:
IR controlled by photocell
WL controlled by telemetry night time only
Attach 1 wire of volt free input into photocell following output on top control board and other
wire of volt free input into telemetry input on bottom board.
Other set up options available...contact Raytec.
9
Trouble Shooting
Ensure all tests are undertaken by a qualified, trained engineer
Ensure safe working practices are followed at all times
Step 1: Basics
• Check polarity of Lamp connection
red=+ve, black=-ve
• Check telemetry link is in
• Check photocell is working
• Check power setting pot fully clockwise
• Check mains input
• Check fuse intact
If OK…
Step 2: Lamp Test
Check voltage of lamp o/p approx 14V (8V for pulsed units)
Check current of lamp – see instructions for correct current setting
To check lamp current (this must be done while both LED panels are connected to
the PSU) remove +ve LED from both lamp supply cables and connect multimeter
set to 10A current in line with the lamp. [One lead of multimeter in common (COM),
other lead into 10A socket of multimeter; set multimeter to 10A readings]. Refer to
PSU Specifications for correct current settings, see pages 6-7.
Step 3: Set-up Camera, lens and illumination
Check alignment of lamp
Check camera lens – fully open at night & set correctly
Check model number to Raytec performance specification to ensure required
distance is achievable
10
Step 4: Call Raytec for further assistance
Note down:
• Model and serial number of illuminator
• Camera make and model
• Lens make and model
If the Raytec lamp is still not delivering the required performance, please contact
us for further assistance.
Additional Information
UL 1838 & CSA 22.2 No 9.0 – 96 Classification
• Suitable for indoor and outdoor use
• Suitable for use in wet locations
• Suitable for mounting on flammable surfaces
• Suitable for combustible surface use
• Suitable for temperatures not exceeding 35°C
Do not connect PSU to an ungrounded supply
Do not install within 10ft of pool or spa
Do not use with dimmers
Do not connect two or more power supplies in parallel
This product must be installed by a person familiar with the construction and operation of
the product and the hazards involved, in accordance with the applicable installation code.
The device is accepted as a component of a landscape lighting system where the
suitability of the combination shall be determined by CSA or local inspection authorities
having jurisdiction. Such systems should be protected by a ground fault circuit interrupter
of the Class A type.
11
UK / Europe
T: +44 (0) 1670 520055
F: +44 (0) 1670 819760
sales@rayteccctv.com
Americas (Toll Free)
T: +1 888 505 8335
ussales@rayteccctv.com
12
RRII/11/5.2
www.rayteccctv.com