177
FIBER
SENSORS
Digital Fiber Sensor
FX-300 SERIES
Related Information
LASER
SENSORS
■■General terms and conditions............ F-17
■■SC-GU1-485................................. P.935~
■■General precautions...................... P.1405
■■Sensor selection guide………………… P.3~
■■Glossary of terms........................ P.1359~
■■Korea’s S-mark.............................. P.1410
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
Recognition
AREA
SENSORS
Certified
LIGHT
CURTAINS
NPN output types of
connector type only
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
* Passed the UL 991 Environment Test
*UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor
manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended
use: UL 991, SEMI S2-0200]
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
PNP output
type available
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
panasonic-electric-works.net/sunx
Constant advances achieving significant
improvement of sensing performance
Stable sensing over long and short periods
FX-301 FX-301-HS FX-305
In addition to a “four-chemical emitting element” which
suppresses changes in the light emitting element over
time so that a stable level of light emission
can
be
•
•
maintained
over
long
periods,
a
“APC
(Auto
Power
•
Control) circuit” has also been adopted afreshly. The
light emitting amount can be controlled in minute
degrees so that even changes occurring over very
short periods can be handled, allowing stable sensing
performance by suppressing deviations in light emitting
amounts caused by changes in the ambient environment
that could not previously be suppressed.
Timer
Interference Light intensity
monitor
prevention
Automatic
sensitivity setting
The digital fiber sensor FX-301(P)
has been modified since its
production in June 2004.
Even greater sensing range
All models
Adoption of a “double coupling lens” that increases
emission efficiency to its maximum limits and greatly
increases sensing range. Sensing ranges with small
diameter fibers and ultra-small diameter fibers, which
have become very popular due to the miniaturization of
chip components, have been increased by 50 % over
previous values achieved with other amplifiers.
• Conventional fiber sensors (Without lens)
● Stable sensing comparison
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
Light emitting amount
Fibers
Short-term stability
Disperses the light reduces
emitting efficiency.
Deviation
• Double coupling lens
Long-term stability
Time
FX-301
FX-301-HS
FX-305
Three-chemical emitting element,
Without APC
The lens concentrates the light, greatly
increasing emitting efficiency.
Digital Fiber Sensor
FX-300 SERIES
APPLICATIONS
178
FIBER
SENSORS
Detecting the presence or absence of labels
Detecting the presence or absence of ICs on a tray
The light-emitting amount selection
function can even stabilize detection
of transparent labels that saturate the
light-receiving level.
You can set upper and lower limits for
the threshold values using the window
comparator mode and turn ON / OFF
the incident light intensity
within that limit.
Detecting the passage of small objects
The differential sensing mode will only
detect rapid changes in the amount of
light, which makes it
possible for small
objects to be
detected.
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
FX-301 FX-301-HS FX-305
Light-emitting amount selection
If the light receiving level becomes saturated during close-range sensing or when sensing
transparent or minute objects, you can adjust the light emitting amount of the sensor to
stabilize sensing without needing to change the response time. Sensing that previously
required the response time or fibers to be changed can now be set much more easily using
this function.
[Light receiving level saturated]
A
4000
Actual digit difference: C
Upper display limit
B
Saturated digit
difference: D
,
A
,
B
Actual digit difference: C’
Level 3
WIRE-SAVING
SYSTEMS
Level 2
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
Level 1
ENDOSCOPE
OFF
Light emitting amount
can be changed
without changing
response time
FX-305
Ultra high-speed 35 µs response FX-301-HS
Large display with 4 digits (9999). With a greater
difference in digit value than previous models, threshold
values can be set in units of 1 digit up to maximum 9999.
Threshold setting can now be done more easily and
accurately.
Ultra high-speed 35 µs response. Even small objects
moving at high speeds can be sensed. In addition, at 65
µs the FX-301 standard
4 times as fast
type and FX-305 highas before
function type is also
twice as fast as previous
models.
Large display 9999
(During STDF, LONG and U-LG modes)
2.5 times
previous
models
● Digit difference comparison
Example Digit difference between object A and object B
Previous models FX-305
4000
9999
35 µs
Ultra high-speed type FX-301-HS
(H-SP mode)
35 μs
Standard type FX-301, High-function type FX-305
65 μs
Digit difference: Large
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
(H-SP mode)
Digit difference: Small
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Level 4
[Stable sensing]
Light emitting
amount
changed
PARTICULAR
USE SENSORS
Previous model
150 μs
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
179
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Digital Fiber Sensor
FX-300 SERIES
FX-305
Simplified systems using new operating modes
A window comparator mode and
differential sensing mode have
been added. These modes make
it easy to carry out sensing tasks
that previously required multiple
sensors or involved complex
threshold settings.
● Window comparator mode
● Differential sensing mode
<Sensing ICs in trays>
<Sensing of tiny moving objects>
LIGHT
CURTAINS
PARTICULAR
USE SENSORS
Tray absent
IC present
Tray present
OFF
ON
OFF
SENSOR
OPTIONS
Upper and lower limits for threshold
values can be set so that the incident light
intensity can turn on and off within those
ranges. Single output is used, so that
only one cable is required, and no PLC
processing is required either.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
Incident
light
intensity
Lower light amounts due to dust
Incident light intensity
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Because sensing is not possible at normal
sensitivity settings, sensitivity must be reset.
ON
ON
Sensing of only sudden changes in light amounts
Only the target objects are sensed.
No need to reset the sensitivity.
FX-305
Equipped with 5 types timers
The FX-305 includes the same ON-delay / OFF-delay / ONE SHOT timer
as the FX-301(-HS), as well as an ON-delay • OFF-delay timer and an
ON-delay • ONE SHOT timer. A wide variety of timer control operations
can be carried out by these fiber sensors alone.
Timer period
Output 1: 0.5 to 9,999 ms (variable)
Output 2: 0.5 to 500 ms (variable)
Time chart
MACHINE VISION
SYSTEMS
ON-delay •
OFF-delay
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
ON-delay •
ONE SHOT
RUN
TEACH
ADJ
RUN→
RUN
TEACH
ADJ
TEACH→
RUN
TEACH
ADJ
ADJ→
T1
ON
OFF
T1
ON
T1
OFF
T1
T1
T2
T2
ON
OFF
ON
OFF
All models
Even beginners can quickly learn how to use the MODE NAVI
MODE NAVI uses six
indicators to display the
amplifier’s basic operations.
The current operating mode
can be confirmed at a glance,
so even a first time user can
easily operate the amplifier
without becoming confused.
OFF
T1
OFF-delay
ONE SHOT
ON
T1
ON-delay
UV CURING
SYSTEMS
Beamreceived
Beaminterrupted
Sensing
condition
FA COMPONENTS
Selection
Guide
For L-ON
L / D L / D ON→
TIMER This mode allows the selection
of output operation as either
PRO Light-ON or Dark-ON.
This is the sensing mode.
Incident light level is displayed
in the digital display.
L / D TIMER→
TIMER This mode permits the
choice of using or not
PRO using the timer.
This mode is for setting
the threshold value.
L / D PRO→
TIMER This mode allows the selection of further
advanced functions, such as the copying of
PRO individual settings and the memory functions.
In this mode, the threshold
value, once set, may be
fine-tuned.
FX-301 FX-301-HS FX-305
Easy confirming of threshold value settings
The threshold value can be confirmed by turning the jog
switch even during RUN mode.
Jog switch is turned
Left: FX-301(-HS)
Right: Output 2 for
Output 1 for FX-305
FX-305
The threshold value is displayed
Digital Fiber Sensor
FX-300 SERIES
All models
The use of only two switches makes for very simple operations
Only two switches, the large
jog switch and the large MODE
key, are required for operation.
You can operate it simply by
the 3 steps shown on the right.
● Large MODE key
● Large jog switch
1
180
FIBER
SENSORS
LASER
SENSORS
2
3
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Pressing the switch selects
or cancels the operating
mode
Moving the switch
from side to side
allows items to be
selected
Pressing the
switch then
confirms the
selected setting
A quick-connection cable saves wiring and
Connector type
work-hours
An optical communication function allows up to *16 sensors
FX-301 FX-305
to be adjusted simultaneously
One unit can be used as either a main unit or sub unit
The optical communication function allows the data that is
currently set to be copied and saved all at once for all amplifiers
connected together from the right side. This greatly reduces
troublesome setup tasks and makes setup much smoother.In
addition, troublesome adjustment operations at times such as
when replacing
sensors can also be
carried out easily
and data can also be
Single copy & save operation for all amplifiers
copied and stored
using the optical
communication
function.
The amplifier unit can be used as either a main unit
or a sub unit. This feature allows for easy mounting in
the side-by-side configuration. The main and sub unit
functions are distinguished only by the proper use of the
main cable and the sub cable.
Moreover, inventory management and maintenance is
simplified.
Identical part numbers eliminate
the need for costly inventory
management labor
* Use the optical communication function for only the same types of sensors. Furthermore,
the FX-301-HS is not equipped with optical communication function capability.
Settings can be entered directly using numerical input All models
Sub cable
FX-305
FX-301(-HS)
FX-301B/G/H
Main cable (4-core)
CN-74-C□
Every function can be directly set merely by the input
of a four digit code (numbers) from the code table. This
convenient feature is easy to set up. In the event that
settings are accidentally changed at the operating site,
merely entering the correct code can restore the original
settings. This results in easy and quick maintenance.
First digit: Settings for response time and hysteresis
Sub cable (2-core)
CN-72-C□
Second digit: Settings for L/D ON and display mode
Main cable (3-core)
Main cable
CN-73-C□
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Sub cable (1-core)
CN-71-C□
Fourth digit: Timer period settings
Third digit: Settings for Adjust lock and timer
Communication unit improves equipment starting up and maintenance
External input unit for digital sensor
FX-CH2
Teaching and changing settings can be performed
by using the PLC and touch panel.
FX-301 FX-305
Upper communication unit for digital sensor SC-GU1-485
Fibers
Amplifiers
We now offer remote maintenance for digital sensors!
Various settings and switching of up to 16 units of
digital fiber sensors can be accomplished at once
without operating the actual sensors themselves, but
via external signals, such as the PLC, touch panel, and
push buttons.
The communication unit enables inputs to the digital fiber
sensors (such as teaching and data bank switching) to
be carried out via a PLC or a personal computer, and
also allows confirming of the incident light intensity an
output status for the fiber sensors. This greatly improves
workability during equipment starting up and maintenance.
<Main functions>
•Batch teaching
•Key lock setting
•Batch loading / saving of
the data bank
<Communicable commands>
• Sensor incident light intensity
• Sensor settings verification
• Sensor output status
• Threshold value settings, etc.
FX-301(P)
FX-305(P)
PLC
Refer to our website for details
Selection
Guide
Compatible with all PLCs equipped
with RS-485 compatible units
SC-GU1-485
RS-485
communication
Refer to SC-GU1-485 pages for details
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
181
Amplifiers Quick-connection cable is not supplied with the amplifier. Please order it separately.
Type
MICRO
PHOTOELECTRIC
SENSORS
Appearance
Model No.
FX-301
AREA
SENSORS
FX-301BP
PNP open-collector transistor
FX-301G
NPN open-collector transistor
NPN open-collector transistor
FX-301HP
High-speed
type
PNP open-collector transistor
FX-301-HS
NPN open-collector transistor
FX-301P-HS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
CN-73-C2
2 m 6.562 ft
CN-73-C5
5 m 16.404 ft
CN-71-C1
1 m 3.281 ft
CN-71-C2
2 m 6.562 ft
CN-71-C5
5 m 16.404 ft
CN-74-C1
1 m 3.281 ft
CN-74-C2
2 m 6.562 ft
CN-74-C5
5 m 16.404 ft
CN-72-C1
1 m 3.281 ft
CN-72-C2
2 m 6.562 ft
CN-72-C5
5 m 16.404 ft
PNP open-collector transistor
PLC /
TERMINALS
FX-305
High-function type
MACHINE
VISION
SYSTEMS
1 m 3.281 ft
Red LED
LASER
MARKERS
FA
COMPONENTS
CN-73-C1
PNP open-collector transistor
Infrared LED
MEASUREMENT
SENSORS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Length
Green LED
FX-301H
WIRE-SAVING
SYSTEMS
HUMAN
MACHINE
INTERFACES
Model No.
Main cable (3-core)
Standard type
NPN open-collector transistor
Blue LED
FX-301GP
SIMPLE
WIRE-SAVING
UNITS
ENDOSCOPE
PNP open-collector transistor
FX-301B
SENSOR
OPTIONS
STATIC
CONTROL
DEVICES
Quick-connection cables
Type
NPN open-collector transistor
FX-301P
PRESSURE /
FLOW
SENSORS
PARTICULAR
USE
SENSORS
Output
Red LED
LIGHT
CURTAINS
INDUCTIVE
PROXIMITY
SENSORS
Emitting element
Sub cable (1-core)
PHOTOELECTRIC
SENSORS
ORDER GUIDE
Main cable (4-core)
LASER
SENSORS
FX-300 SERIES
Sub cable (2-core)
FIBER
SENSORS
Digital Fiber Sensor
NPN open-collector transistor
Red LED
FX-305P
PNP open-collector transistor
Digital Fiber Sensor
FX-300 SERIES
ORDER GUIDE
182
FIBER
SENSORS
Quick-connection cables
LASER
SENSORS
For FX-301(-HS)/B/G/H Quick-connection cable is not supplied with the amplifier. Please order it separately.
Main cable
PHOTOELECTRIC
SENSORS
Type
Main cable
(3-core)
Sub cable
(1-core)
Model No.
CN-73-C1
Description
Length: 1 m 3.281 ft
CN-73-C5
0.15 mm2 3-core cabtyre cable, with connector
Length: 2 m 6.562 ft on one end
Cable outer diameter: ø3.0 mm ø0.118 in
Length: 5 m 16.404 ft
CN-71-C1
Length: 1 m 3.281 ft
CN-73-C2
CN-71-C2
CN-71-C5
MICRO
PHOTOELECTRIC
SENSORS
•CN-73-C□
0.15 mm2 1-core cabtyre cable, with connector
Length: 2 m 6.562 ft on one end
Cable outer diameter: ø3.0 mm ø0.118 in
Length: 5 m 16.404 ft
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
Sub cable
INDUCTIVE
PROXIMITY
SENSORS
•CN-71-C□
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
For FX-305 Quick-connection cable is not supplied with the amplifier. Please order it separately.
Type
Main cable
(4-core)
Sub cable
(2-core)
Model No.
CN-74-C1
Description
CN-74-C5
CN-72-C1
Length: 1 m 3.281 ft
CN-72-C2
CN-72-C5
Main cable
WIRE-SAVING
SYSTEMS
•CN-74-C□
MEASUREMENT
SENSORS
Length: 1 m 3.281 ft
0.15 mm2 4-core cabtyre cable, with connector
Length: 2 m 6.562 ft on one end
Cable outer diameter: ø3.0 mm ø0.118 in
Length: 5 m 16.404 ft
CN-74-C2
SIMPLE
WIRE-SAVING
UNITS
0.15 mm2 2-core cabtyre cable, with connector
Length: 2 m 6.562 ft on one end
Cable outer diameter: ø3.0 mm ø0.118 in
Length: 5 m 16.404 ft
STATIC
CONTROL
DEVICES
ENDOSCOPE
Sub cable
LASER
MARKERS
•CN-72-C□
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.
Appearance
Model No.
MS-DIN-E
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
Description
MACHINE
VISION
SYSTEMS
When cascading multiple amplifiers, or when it
moves depending on the way it is installed on a
DIN rail, these end plates clamp amplifiers into
place on both sides. Make sure to use end plates
when cascading multiple amplifiers together.
UV
CURING
SYSTEMS
Two pcs. per set
Selection
Guide
OPTIONS
Fibers
Amplifiers
Amplifier mounting bracket
Model No.
Amplifier
mounting bracket
MS-DIN-2
Mounting bracket for amplifier
FX-300
FX-410
FX-MB1
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplifier, as well as, prevents effect on another amplifier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quickconnection cable.
Fiber amplifier
protection seal
Description
FX-500
Designation
Note: Fiber amplifier protection seals are supplied with the FX-301(P) and FX-305(P).
•MS-DIN-2
FX-100
FX-311
FX-301-F7/
FX-301-F
Fiber amplifier protection seal
•FX-MB1
Communication
window seal
Connector seal
183
FIBER
SENSORS
Digital Fiber Sensor
FX-300 SERIES
LIST OF FIBERS
LASER
SENSORS
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
PHOTOELECTRIC
SENSORS
Thru-beam type (one pair set)
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
Sensing range (mm in) (Note 2)
Model No.
Red LED
U-LG
FT-30
LONG
STDF
210 8.268
STD
150 5.906
Dimensions
FAST
450 17.717
310 12.205
110 4.331
FT-31
440 17.323
290 11.417
200 7.874
142 5.591
105 4.134
FT-40
1,300 51.181
900 35.433
600 23.622
450 17.717
330 12.992
FT-41
1,000 39.370
780 30.709
500 19.685
400 15.748
280 11.024
FT-42
1,100 43.307
800 31.496
550 21.654
400 15.748
285 11.220
FT-A8
3,500 137.795 (Note 3) 3,500 137.795 (Note 3)
3,300 129.921
1,500 59.055
1,100 43.307
FT-A30
3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3)
H-SP
S-D
60 2.362
P.90
58 2.283
49 1.929
P.90
180 7.087
180 7.087
P.90
150 5.906
130 5.118
P.90
160 6.299
150 5.906
P.90
1,080 42.520
750 29.528
P.90
3,000 118.110 3,500 137.795 (Note 3)
P.90
60 2.362
FT-AFM2
850 33.465
650 25.591
380 14.961
330 12.992
220 8.661
100 3.937
115 4.528
P.90
FT-AFM2E
800 31.496
590 23.228
350 13.780
290 11.417
200 7.874
90 3.543
100 3.937
P.90
1,600 62.992
1,100 43.307
700 27.559
530 20.866
400 15.748
200 7.874
180 7.087
P.90
20 0.787
18 0.709
13 0.512
10 0.394
8 0.315
3 0.118
3 0.118
P.91
FT-B8
FT-E12
FT-E13
20 0.787
13 0.512
9 0.354
6 0.236
5 0.197
2 0.079
2 0.079
P.91
FT-E22
130 5.118
80 3.150
60 2.362
50 1.969
36 1.417
18 0.709
15 0.591
P.91
FT-E23
95 3.740
65 2.559
42 1.654
31 1.220
22 0.866
12 0.472
12 0.472
P.91
FT-FM2
1,000 39.370
780 30.709
500 19.685
400 15.748
280 11.024
150 5.906
130 5.118
P.91
FT-FM2S
1,000 39.370
780 30.709
500 19.685
400 15.748
280 11.024
150 5.906
130 5.118
P.91
FT-FM2S4
1,000 39.370
780 30.709
500 19.685
400 15.748
280 11.024
150 5.906
130 5.118
P.91
19,500 767.717 (Note 4) 19,500 767.717 (Note 4) 19,500 767.717 (Note 4)
14,000 551.180
10,000 393.700
3,500 137.795
3,800 149.606
P.91
FT-FM10L
FT-H13-FM2
1,200 47.244
880 34.646
550 21.654
440 17.323
300 11.811
150 5.906
155 6.102
P.91
FT-H20-J20-S (Note 5)
530 20.866
390 15.354
225 8.858
200 7.874
140 5.512
60 2.362
60 2.362
P.92
FT-H20-J30-S (Note 5)
530 20.866
390 15.354
225 8.858
200 7.874
140 5.512
60 2.362
60 2.362
P.92
FT-H20-J50-S (Note 5)
530 20.866
390 15.354
225 8.858
200 7.874
140 5.512
60 2.362
60 2.362
P.92
FT-H20-M1
750 29.528
550 21.654
320 12.598
280 11.024
200 7.874
85 3.346
90 3.543
P.92
FT-H20-VJ50-S (Note 5)
840 33.071
550 21.654
370 14.567
280 11.024
200 7.874
90 3.543
90 3.543
P.92
FT-H20-VJ80-S (Note 5)
840 33.071
550 21.654
370 14.567
280 11.024
200 7.874
90 3.543
90 3.543
P.92
FT-H20W-M1
420 16.535
310 12.205
180 7.087
140 5.512
100 3.937
40 1.575
50 1.969
P.92
FT-H30-M1V-S (Note 6)
350 13.780
250 9.843
150 5.906
125 4.921
90 3.543
50 1.969
40 1.575
P.92
FT-H35-M2
750 29.528
550 21.654
330 12.992
280 11.024
200 7.874
85 3.346
90 3.543
P.92
FT-H35-M2S6
750 29.528
550 21.654
330 12.992
280 11.024
200 7.874
85 3.346
90 3.543
P.92
FT-HL80Y
FT-K8
3,500 137.795 (Note 3) 3,500 137.795 (Note 3)
3,000 118.110
2,000 78.740
1,800 70.866
1,350 53.150
900 35.433
450 17.717
480 18.898
P.92
1,500 59.055
1,000 39.370
800 31.496
300 11.811
350 13.780
P.93
FT-KV1
600 23.622
500 19.685
300 11.811
250 9.843
180 7.087
90 3.543
100 3.937
P.93
FT-KV8
3,000 118.110
2,000 78.740
1,500 59.055
1,000 39.370
800 31.496
300 11.811
350 13.780
P.93
FT-L80Y
3,500 137.795
3,500 137.795
2,000 78.740
1,500 59.055
1,000 39.370
500 19.685
530 20.866
P.93
FT-NFM2
400 15.748
270 10.630
200 7.874
140 5.512
100 3.937
55 2.165
49 1.929
P.93
FT-NFM2S
400 15.748
270 10.630
200 7.874
140 5.512
100 3.937
55 2.165
49 1.929
P.93
FT-NFM2S4
400 15.748
270 10.630
200 7.874
140 5.512
100 3.937
55 2.165
49 1.929
P.93
FT-P2
350 13.780
280 11.024
160 6.299
120 4.724
90 3.543
40 1.575
42 1.654
P.93
FT-P40
350 13.780
250 9.843
150 5.906
100 3.937
75 2.953
30 1.181
35 1.378
P.93
FT-P60
550 21.654
400 15.748
250 9.843
190 7.480
140 5.512
70 2.756
80 3.150
P.93
Notes:1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
4) The fiber cable length practically limits the sensing range to 19,500 mm 767.717 in long.
5) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set.
6) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
Digital Fiber Sensor
FX-300 SERIES
LIST OF FIBERS
FIBER
SENSORS
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Thru-beam type (one pair set)
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
Red LED
LONG
STDF
STD
Dimensions
FAST
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Sensing range (mm in) (Note 2)
Model No.
U-LG
184
H-SP
S-D
FT-P80
900 35.433
650 25.591
400 15.748
320 12.598
230 9.055
100 3.937
110 4.331
P.93
FT-P81X
900 35.433
650 25.591
380 14.961
320 12.598
230 9.055
100 3.937
110 4.331
P.94
FT-PS1
100 3.937
80 3.150
50 1.969
40 1.575
30 1.181
13 0.512
17 0.669
P.93
FT-R80
740 29.134
530 20.866
320 12.598
230 9.055
150 5.906
75 2.953
80 3.150
P.94
FT-S20
450 17.717
310 12.205
210 8.268
150 5.906
110 4.331
60 2.362
60 2.362
P.94
FT-S21
440 17.323
290 11.417
200 7.874
142 5.591
105 4.134
58 2.283
49 1.929
P.94
FT-S30
1,300 51.181
900 35.433
600 23.622
450 17.717
330 12.992
180 7.087
180 7.087
P.94
FT-SFM2
1,000 39.370
780 30.709
500 19.685
400 15.748
280 11.024
150 5.906
130 5.118
P.94
FT-SFM2L
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
2,000 78.740
1,600 62.992
820 32.283
800 31.496
580 22.835
170 6.693
280 11.024
P.94
FT-SFM2SV2
550 21.654
400 15.748
240 9.449
200 7.874
140 5.512
65 2.559
70 2.756
P.94
FT-SNFM2
400 15.748
270 10.630
200 7.874
140 5.512
100 3.937
55 2.165
49 1.929
P.95
FT-T80
1,000 39.370
780 30.709
500 19.685
400 15.748
280 11.024
150 5.906
130 5.118
P.95
FT-V10
2,350 92.520
2,000 78.740
1,400 55.118
1,000 39.370
800 31.496
340 13.386
350 13.780
P.95
STATIC
CONTROL
DEVICES
FT-V22
410 16.142
390 15.354
220 8.661
180 7.087
125 4.921
60 2.362
63 2.480
P.95
ENDOSCOPE
FT-V41
220 8.661
175 6.890
100 3.937
80 3.150
60 2.362
25 0.984
27 1.063
P.95
1,000 39.370
800 31.496
500 19.685
400 15.748
280 11.024
120 4.724
140 5.512
P.95
FT-W4
220 8.661
160 6.299
100 3.937
80 3.150
55 2.165
25 0.984
28 1.102
P.95
FT-W8
750 29.528
570 22.441
350 13.780
290 11.417
200 7.874
90 3.543
100 3.937
P.95
FT-WA8
3,500 137.795 (Note 3) 3,500 137.795 (Note 3)
3,300 129.921
1,500 59.055
1,100 43.307
1,080 42.520
750 29.528
P.95
FT-WA30
3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3) 3,500 137.795 (Note 3)
3,000 118.110 3,500 137.795 (Note 3)
P.95
FT-V80Y
FT-WKV8
2,200 86.614
1,700 66.929
1,000 39.370
700 27.559
600 23.622
280 11.024
300 11.811
P.96
FT-WR80
750 29.528
570 22.441
350 13.780
290 11.417
200 7.874
90 3.543
100 3.937
P.96
1,500 59.055
1,200 47.244
750 29.528
600 23.622
420 16.535
200 7.874
210 8.268
P.96
FT-WS3
780 30.709
570 22.441
340 13.386
290 11.417
200 7.874
90 3.543
100 3.937
P.96
FT-WS4
220 8.661
160 6.299
100 3.937
80 3.150
55 2.165
25 0.984
28 1.102
P.96
FT-WR80L
FT-WS8
750 29.528
570 22.441
350 13.780
290 11.417
200 7.874
90 3.543
100 3.937
P.96
FT-WS8L
1,500 59.055
1,200 47.244
750 29.528
600 23.622
420 16.535
200 7.874
210 8.268
P.96
FT-WV42
120 4.724
90 3.543
55 2.165
40 1.575
30 1.181
13 0.512
15 0.591
P.96
300 11.811
200 7.874
140 5.512
100 3.937
70 2.756
40 1.575
40 1.575
P.96
220 8.661
150 5.906
105 4.134
75 2.953
50 1.969
30 1.181
30 1.181
P.97
FT-WZ7
660 25.984
440 17.323
308 12.126
220 8.661
150 5.906
80 3.150
80 3.150
P.97
FT-WZ7HB
870 34.252
580 22.835
406 15.984
290 11.417
210 8.268
110 4.331
110 4.331
P.97
FT-WZ8
950 37.402
700 27.559
420 16.535
330 12.992
240 9.449
100 3.937
120 4.724
P.97
FT-WZ8E
2,100 82.677
1,500 59.055
950 37.402
700 27.559
500 19.685
200 7.874
210 8.268
P.97
FT-WZ8H
3,500 137.795
2,500 98.425
1,600 62.992
1,200 47.244
850 33.465
400 15.748
410 16.142
P.97
1,100 43.307
800 31.496
500 19.685
400 15.748
300 11.811
120 4.724
140 5.512
P.97
FT-WZ4
FT-WZ4HB
FT-Z8
FT-Z8E
1,850 72.835
1,600 62.992
950 37.402
800 31.496
600 23.622
250 9.843
280 11.024
P.97
FT-Z8H
3,100 122.047
2,700 106.299
1,550 61.024
1,400 55.118
1,000 39.370
420 16.535
490 19.291
P.97
FT-Z802Y
3,500 137.795
3,500 137.795
3,000 118.110
1,500 59.055
1,000 39.370
500 19.685
530 20.866
P.97
Notes:1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
185
FIBER
SENSORS
Digital Fiber Sensor
FX-300 SERIES
LIST OF FIBERS
LASER
SENSORS
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
PHOTOELECTRIC
SENSORS
Retroreflective type
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
Sensing range (mm in) (Note 2, 3)
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
Red LED
Model No.
U-LG
FR-KV1
LONG
STDF
STD
Dimensions
FAST
H-SP
S-D
15 to 370 0.591 to 14.567 15 to 330 0.591 to 12.992 15 to 240 0.591 to 9.449 15 to 210 0.591 to 8.268 15 to 170 0.591 to 6.693 15 to 80 0.591 to 3.150 15 to 90 0.591 to 3.543
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
P.98
FR-KZ21E
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
20 to 200 0.787 to 7.874
P.98
FR-WKZ11
100 to 910 3.937 to 35.827 100 to 730 3.937 to 28.740 100 to 600 3.937 to 23.622 100 to 520 3.937 to 20.472 100 to 460 3.937 to 18.110
–
–
P.98
Notes:1)Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode.
2)Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
The sensing range of FR-WKZ11 is specified for the RF-13. The sensing range of FR-KZ21 and FR-KZ21E is specified for the attached reflector RF-003.
The sensing range of FR-KV1 is specified for the attached reflector.
3)The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for
the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If
this occurs, adjust the threshold value of the amplifier unit before use.
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Reflective type
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
Sensing range (mm in) (Note 2, 3)
Model No.
Red LED
U-LG
FD-30
FD-31
FD-40
FD-41
FD-60
FD-61
FD-A15
FD-AFM2
FD-AFM2E
FD-B8
FD-E12
FD-E22
FD-EG1
FD-EG2
FD-EG3
FD-EN500S1
FD-ENM1S1
170 6.693
150 5.906
170 6.693
150 5.906
500 19.685
440 17.323
230 9.055
290 11.417
290 11.417
600 23.622
15 0.591
65 2.559
50 1.969
40 1.575
20 0.787
6.5 0.256
50 1.969
LONG
110 4.331
95 3.740
110 4.331
95 3.740
350 13.780
320 12.598
200 7.874
220 8.661
220 8.661
480 18.898
11 0.433
45 1.772
38 1.496
25 0.984
15 0.591
5 0.197
38 1.496
STDF
70 2.756
63 2.480
70 2.756
63 2.480
240 9.449
205 8.071
150 5.906
135 5.315
135 5.315
280 11.024
8 0.315
28 1.102
25 0.984
14 0.551
9 0.354
3 0.118
20 0.787
STD
50 1.969
45 1.772
50 1.969
45 1.772
160 6.299
145 5.709
150 5.906
110 4.331
110 4.331
220 8.661
6 0.236
23 0.906
18 0.709
12 0.472
8 0.315
3 0.118
18 0.709
Dimensions
FAST
40 1.575
35 1.378
40 1.575
35 1.378
130 5.118
105 4.134
100 3.937
78 3.071
78 3.071
160 6.299
4 0.157
17 0.669
14 0.551
9 0.354
5 0.197
2 0.079
14 0.551
H-SP
20 0.787
17 0.669
20 0.787
17 0.669
70 2.756
65 2.559
45 1.772
35 1.378
35 1.378
85 3.346
2 0.079
8 0.315
5 0.197
3 0.118
2.5 0.098
Cannot use
5 0.197
S-D
18 0.709
16 0.630
18 0.709
16 0.630
70 2.756
60 2.362
50 1.969
39 1.535
39 1.535
75 2.953
1 0.039
7 0.276
6 0.236
5 0.197
3 0.118
Cannot use
6 0.236
P.99
P.99
P.99
P.99
P.99
P.99
P.99
P.99
P.99
P.99
P.100
P.100
P.100
P.100
P.100
P.100
P.100
FD-F4
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
P.100
FD-F41
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
P.100
FD-F41Y
ø4 mm ø0.157 in form Protective tube: fluorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
–
–
–
–
–
–
–
P.101
P.101
P.101
P.101
P.101
P.101
P.102
P.102
P.101
P.102
P.102
P.102
FX-300
FD-F8Y
FX-410
FD-FA90
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe (When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in) [PFA (fluorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
FX-311
FD-FM2
FD-FM2S
FD-FM2S4
FD-G4
FD-G6
FD-G6X
FD-G40
FD-G60
FD-H13-FM2
FD-H18-L31
410 16.142
310 12.205
200 7.874
140 5.512
100 3.937
370 14.567
270 10.630
170 6.693
110 4.331
85 3.346
370 14.567
270 10.630
170 6.693
110 4.331
85 3.346
150 5.906
110 4.331
65 2.559
55 2.165
42 1.654
150 5.906
110 4.331
65 2.559
55 2.165
42 1.654
150 5.906
90 3.543
48 1.890
45 1.772
35 1.378
150 5.906
110 4.331
65 2.559
55 2.165
42 1.654
410 16.142
310 12.205
200 7.874
140 5.512
100 3.937
410 16.142
310 12.205
200 7.874
140 5.512
100 3.937
0 to 20 0 to 0.787 0 to 15 0 to 0.591 0 to 10 0 to 0.394 0 to 10 0 to 0.394 1 to 8 0.039 to 0.315
FX-301-F7/
FX-301-F
P.98
FR-KZ21
LASER
MARKERS
PLC /
TERMINALS
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
55 2.165
47 1.850
45 1.772
39 1.535
45 1.772
39 1.535
15 0.591
19 0.748
15 0.591
19 0.748
12 0.472
20 0.787
15 0.591
19 0.748
55 2.165
47 1.850
55 2.165
47 1.850
Cannot use
2 to 6 0.079 to 0.236
Notes:1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode.
2) The standard sensing objects of the sensing ranges vary depending on the fibers.
3) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
P.101
Digital Fiber Sensor
FX-300 SERIES
LIST OF FIBERS
FIBER
SENSORS
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Reflective type
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
Red LED
U-LG
FD-HF40Y
FD-L4
FD-L41
LONG
STDF
STD
Dimensions
FAST
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Sensing range (mm in) (Note 2, 3)
Model No.
FD-H20-21
FD-H20-M1
FD-H25-L43
FD-H25-L45
FD-H30-KZ1V-S (Note 4)
FD-H30-L32
FD-H30-L32V-S (Note 4)
FD-H35-20S
FD-H35-M2
FD-H35-M2S6
186
H-SP
S-D
300 11.811
270 10.630
150 5.906
140 5.512
100 3.937
35 1.378
47 1.850
300 11.811
270 10.630
150 5.906
140 5.512
100 3.937
35 1.378
47 1.850
3 to 28 0.118 to 1.102 3 to 25 0.118 to 0.984 4 to 23 0.157 to 0.906 4 to 20 0.118 to 0.787 4 to 19 0.118 to 0.748 4 to 16 0.118 to 0.630 4 to 16 0.118 to 0.630
–
–
–
5 to 42 0.197 to 1.654 6 to 41 0.236 to 1.614 6 to 40 0.236 to 1.575 7 to 38 0.276 to 1.496
20 to 300 0.787 to 11.811 20 to 200 0.787 to 7.874 20 to 150 0.787 to 5.906 25 to 130 0.984 to 5.118 30 to 100 1.181 to 3.937
Cannot use
Cannot use
0 to 20 0 to 0.787 0 to 15 0 to 0.591 0 to 10 0 to 0.394 0 to 10 0 to 0.394 1 to 8 0.039 to 0.315
Cannot use
2 to 6 0.079 to 0.236
0 to 11 0 to 0.433 0 to 8 0 to 0.315 1.5 to 6 0.059 to 0.236 1.5 to 5 0.059 to 0.197 2 to 4 0.079 to 0.157
Cannot use
Cannot use
190 7.480
160 6.299
80 3.150
80 3.150
57 2.244
20 0.787
26 1.024
300 11.811
270 10.630
150 5.906
140 5.512
100 3.937
35 1.378
47 1.850
300 11.811
270 10.630
150 5.906
140 5.512
100 3.937
35 1.378
47 1.850
ø4 mm ø0.157 in form Protective tube: fluorine resin, length:500 mm 19.685 in (allowable cutting)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
2 to 20 0.079 to 0.787 2.5 to 18 0.098 to 0.709 4 to 12 0.157 to 0.472 4 to 12 0.157 to 0.472 4.5 to 11 0.177 to 0.433 5 to 8.5 0.197 to 0.335 4.8 to 9.5 0.189 to 0.374
(Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236)
2 to 19 0.079 to 0.748 2.5 to 18 0.098 to 0.709 3 to 16 0.118 to 0.630 3 to 16 0.118 to 0.630 3.5 to 15 0.138 to 0.591
Cannot use
Cannot use
(Convergent point 8 0.315) (Convergent point 8 0.315) (Convergent point 8 0.315) (Convergent point 8 0.315) (Convergent point 8 0.315)
P.102
P.102
P.103
P.103
P.103
P.103
P.103
P.104
P.104
P.104
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
P.104
SIMPLE
WIRE-SAVING
UNITS
P.104
WIRE-SAVING
SYSTEMS
P.104
MEASUREMENT
SENSORS
–
–
–
–
–
0 to 7 0 to 0.276
0 to 4.5 0 to 0.177
0 to 36 0 to 1.417
10 to 33 0.394 to 1.299
(Note 5)
0 to 6.5 0 to 0.256
0 to 4 0 to 0.157
0 to 33 0 to 1.299
10 to 32 0.394 to 1.260
(Note 5)
0 to 23 0 to 0.906
0 to 6 0 to 0.236
0 to 4 0 to 0.157
0 to 30 0 to 1.181
10 to 32 0.394 to 1.260
(Note 5)
–
0 to 8.2 0 to 0.323
0 to 4.7 0 to 0.185
0 to 50 0 to 1.969
10 to 33 0.394 to 1.299
(Note 5)
0 to 5.7 0 to 0.224
0 to 3.8 0 to 0.150
0 to 30 0 to 1.181
10 to 32 0.394 to 1.260
(Note 5)
0 to 5 0 to 0.197
0 to 3 0 to 0.118
0 to 15 0 to 0.591
13 to 18 0.512 to 0.709
(Note 5)
0 to 5.2 0 to 0.205
0 to 3.5 0 to 0.138
0 to 21 0 to 0.827
13 to 18 0.512 to 0.709
(Note 5)
12.5 to 37.5 0.492 to 1.476
30 1.181
90 3.543
90 3.543
90 3.543
50 1.969
36 1.417
90 3.543
90 3.543
220 8.661
185 7.283
185 7.283
110 4.331
95 3.740
270 10.630
100 3.937
90 3.543
90 3.543
270 10.630
55 2.165
190 7.480
30 1.181
65 2.559
20 to 480 0.787 to 18.898
6.5 to 14 0.256 to 0.551
(Convergent point 8 0.315)
15 to 36 0.591 to 1.417
30 1.181
60 2.362
60 2.362
60 2.362
30 1.181
20 0.787
55 2.165
55 2.165
130 5.118
100 3.937
110 4.331
70 2.756
63 2.480
170 6.693
55 2.165
60 2.362
60 2.362
170 6.693
30 1.181
110 4.331
18 0.709
37 1.457
20 to 300 0.787 to 11.811
7 to 14 0.276 to 0.551
(Convergent point 8 0.315)
15 to 35 0.591 to 1.378
30 1.181
45 1.772
45 1.772
45 1.772
25 0.984
18 0.709
45 1.772
45 1.772
100 3.937
80 3.150
85 3.346
50 1.969
45 1.772
110 4.331
45 1.772
45 1.772
45 1.772
110 4.331
25 0.984
90 3.543
15 0.591
32 1.260
20 to 230 0.787 to 9.055
7 to 12 0.276 to 0.472
(Convergent point 8 0.315)
16 to 29 0.630 to 1.142
Cannot use
Cannot use
1 to 28 0.039 to 1.102 2 to 27 0.079 to 1.063 2 to 27 0.079 to 1.063
35 1.378
16 0.630
16 0.630
35 1.378
16 0.630
16 0.630
35 1.378
16 0.630
16 0.630
19 0.748
7.5 0.295
9 0.354
14 0.551
5.5 0.217
6 0.236
30 1.181
13 0.512
16 0.630
30 1.181
13 0.512
16 0.630
70 2.756
30 1.181
35 1.378
60 2.362
30 1.181
35 1.378
60 2.362
25 0.984
30 1.181
40 1.575
20 0.787
18 0.709
35 1.378
17 0.669
16 0.630
85 3.346
45 1.772
39 1.535
32 1.260
15 0.591
16 0.630
35 1.378
16 0.630
16 0.630
35 1.378
16 0.630
16 0.630
85 3.346
45 1.772
39 1.535
17 0.669
8 0.315
9 0.354
60 2.362
25 0.984
32 1.260
12 0.472
4.5 0.177
5 0.197
25 0.984
10 0.394
11 0.433
20 to 170 0.787 to 6.693 25 to 90 0.984 to 3.543 25 to 100 0.984 to 3.937
7.5 to 12 0.295 to0.472
Cannot use
Cannot use
(Convergent point 8 0.315)
P.105
P.105
P.105
P.105
P.105
P.105
P.105
P.105
P.105
P.105
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.107
P.107
P.107
P.107
FD-WL41
12 to 50 0.472 to 1.969
30 1.181
140 5.512
140 5.512
140 5.512
80 3.150
50 1.969
130 5.118
130 5.118
300 11.811
270 10.630
240 9.449
170 6.693
150 5.906
370 14.567
170 6.693
140 5.512
140 5.512
370 14.567
80 3.150
250 9.843
40 1.575
85 3.346
20 to 660 0.787 to 25.984
6.5 to 14.5 0.256 to 0.571
(Convergent point 8 0.315)
P.107
FX-300
FD-WL48
FD-WS8
FD-WSG4
FD-WT4
FD-WT8
FD-WV42
FD-WZ4
FD-WZ4HB
FD-WZ7
FD-WZ7HB
0.5 to 8.5 0.020 to 0.335
250 9.843
85 3.346
40 1.575
250 9.843
20 0.787
1 to 50 0.039 to 1.969
1 to 70 0.039 to 2.756
200 7.874
0.5 to 270 0.020 to 10.630
0.5 to 7.5 0.020 to 0.295
190 7.480
65 2.559
30 1.181
190 7.480
15 0.591
1.5 to 34 0.059 to 1.339
1 to 46 0.039 to 1.811
120 4.724
0.5 to 180 0.020 to 7.087
1 to 6.5 0.039 to 0.256
110 4.331
37 1.457
18 0.709
110 4.331
8.5 0.335
2 to 24 0.079 to 0.945
1 to 32.2 0.039 to 1.268
1 to 84 0.039 to 3.307
1 to 126 0.039 to 4.961
1 to 5.5 0.039 to 0.217
90 3.543
32 1.260
15 0.591
90 3.543
7 0.276
3 to 17 0.118 to 0.669
2.5 to 23 0.098 to 0.906
1 to 60 0.039 to 2.362
1 to 90 0.039 to 3.543
1 to 5 0.039 to 0.197
Cannot use
Cannot use
60 2.362
25 0.984
32 1.260
25 0.984
10 0.394
11 0.433
12 0.472
4.5 0.177
5 0.197
60 2.362
25 0.984
32 1.260
5 0.197
Cannot use
Cannot use
–
–
3 to 10 0.118 to 0.394
2.5 to 15 0.098 to 0.591 3 to 7 0.118 to 0.276 3 to 7 0.118 to 0.276
1.5 to 35 0.059 to 1.378 2.5 to 18 0.098 to 0.709 2.5 to 18 0.098 to 0.709
1 to 70 0.039 to 2.756 1 to 35 0.039 to 1.378 1 to 35 0.039 to 1.378
P.107
P.107
P.107
P.107
P.107
P.108
P.108
P.108
P.108
P.108
FX-410
FD-L43
FD-L44
FD-L44S
FD-L45
FD-L45A
FD-L46
FD-L47
FD-NFM2
FD-NFM2S
FD-NFM2S4
FD-P2
FD-P40
FD-P50
FD-P60
FD-P80
FD-P81X
FD-R80
FD-S30
FD-S31
FD-S80
FD-SFM2SV2
FD-SNFM2
FD-T40
FD-T80
FD-V41
FD-W8
FD-W44
FD-WG4
FD-WKZ1
Notes:1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode.
2) The standard sensing objects of the sensing ranges vary depending on the fibers.
3) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
5) Sensing distance varies depending on the sensing object’s inclination.
P.104
P.104
P.104
P.104
STATIC
CONTROL
DEVICES
ENDOSCOPE
P.105
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-311
FX-301-F7/
FX-301-F
187
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
Digital Fiber Sensor
FX-300 SERIES
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
Thru-beam type (One pair set)
Fibers are listed in alphabetic order. Refer to p.5~ for details of each fiber.
Sensing range (mm in) (Note 1)
FX-301B
Model No.
LONG
FT-30
55 2.165
STD
28 1.102
FX-301G
FAST
18 0.709
LONG
28 1.102
STD
13 0.512
FX-301H (Note 2)
FAST
9 0.354
LONG
25 0.984
STD
13 0.512
Dimensions
FAST
9 0.354
P.90
FT-31
50 1.969
25 0.984
16 0.630
24 0.945
12 0.472
8 0.315
23 0.906
11 0.433
8 0.315
P.90
FT-40
155 6.102
76 2.992
45 1.772
90 3.543
40 1.575
26 1.024
80 3.150
43 1.693
27 1.063
P.90
FT-41
150 5.906
75 2.953
40 1.575
70 2.756
35 1.378
24 0.945
50 1.969
25 0.984
18 0.709
P.90
FT-42
150 5.906
75 2.953
40 1.575
80 3.150
35 1.378
24 0.945
75 2.953
40 1.575
25 0.984
P.90
FT-A8
600 23.622
300 11.811
220 8.661
300 11.811
150 5.906
110 4.331
220 8.661
110 4.331
80 3.150
P.90
FT-A30
2,400 94.488
1,200 47.244
700 27.559
1,200 47.244
600 23.622
350 13.780
800 31.496
400 15.748
240 9.449
P.90
FT-AFM2
120 4.724
60 2.362
40 1.575
60 2.362
30 1.181
20 0.787
48 1.890
24 0.945
18 0.709
P.90
FT-AFM2E
120 4.724
60 2.362
40 1.575
60 2.362
30 1.181
20 0.787
48 1.890
24 0.945
18 0.709
P.90
FT-B8
220 8.661
110 4.331
75 2.953
110 4.331
40 1.575
30 1.181
P.90
100 3.937
50 1.969
1 0.039
–
55 2.165
–
4 0.157
2 0.079
1 0.039
–
–
2 0.079
1 0.039
FT-E12
3 0.118
2 0.079
FT-E13
2 0.079
1 0.039
FT-E22
14 0.551
7 0.276
4 0.157
6 0.236
3 0.118
2 0.079
10 0.394
5 0.197
3 0.118
P.91
FT-E23
8 0.315
4 0.157
3 0.118
4 0.157
2 0.079
1 0.039
10 0.394
5 0.197
3 0.118
P.91
FT-FM2
150 5.906
75 2.953
40 1.575
70 2.756
35 1.378
24 0.945
50 1.969
25 0.984
18 0.709
P.91
FT-FM2S
150 5.906
75 2.953
40 1.575
70 2.756
35 1.378
24 0.945
50 1.969
25 0.984
18 0.709
P.91
24 0.945
50 1.969
25 0.984
18 0.709
P.91
1,000 39.370 2,400 94.488 (Note 3) 1,200 47.244 (Note 3) 900 35.433 (Note 3)
P.91
1 0.039
–
1.5 0.059
–
P.91
P.91
FT-FM2S4
150 5.906
75 2.953
40 1.575
70 2.756
35 1.378
FT-FM10L
5,400 212.598
2,700 106.299
1,900 74.803
2,800 110.236
1,400 55.118
FT-H13-FM2
72 2.835
36 1.417
FT-H20-J20-S (Note 4)
60 2.362
20 0.787
–
35 1.378
–
–
20 0.787
–
–
P.92
FT-H20-J30-S (Note 4)
60 2.362
20 0.787
–
35 1.378
–
–
20 0.787
–
–
P.92
60 2.362
20 0.787
–
35 1.378
–
–
20 0.787
–
–
P.92
100 3.937
50 1.969
FT-H20-J50-S (Note 4)
FT-H20-M1
26 1.024
35 1.378
32 1.260
50 1.969
16 0.630
25 0.984
10 0.394
18 0.709
–
P.92
85 3.346
30 1.181
85 3.346
30 1.181
–
FT-H20W-M1
44 1.732
22 0.866
FT-H30-M1V-S (Note 5)
40 1.575
20 0.787
FT-H35-M2
100 3.937
50 1.969
35 1.378
50 1.969
25 0.984
18 0.709
550 21.654
280 11.024
160 6.299
P.92
FT-H35-M2S6
100 3.937
50 1.969
35 1.378
50 1.969
25 0.984
18 0.709
550 21.654
280 11.024
160 6.299
P.92
FT-K8
–
160 6.299
P.91
FT-H20-VJ80-S (Note 4)
FT-HL80Y
50 1.969
280 11.024
25 0.984
FT-H20-VJ50-S (Note 4)
14 0.551
–
550 21.654
35 1.378
–
–
50 1.969
–
70 2.756
22 0.866
20 0.787
11 0.433
–
7 0.276
–
30 1.181
–
–
P.92
30 1.181
–
–
P.92
220 8.661
20 0.787
100 3.937
–
70 2.756
–
P.92
P.92
80 3.150
40 1.575
25 0.984
110 4.331
55 2.165
40 1.575
1,100 43.307
550 21.654
350 13.780
P.92
400 15.748
200 7.874
130 5.118
200 7.874
100 3.937
65 2.559
150 5.906
75 2.953
40 1.575
P.93
–
–
–
–
–
–
FX-500
FT-KV1
80 3.150
35 1.378
10 0.394
FX-100
FT-KV8
400 15.748
200 7.874
130 5.118
200 7.874
100 3.937
65 2.559
150 5.906
75 2.953
40 1.575
P.93
FX-300
FT-L80Y
160 6.299
80 3.150
50 1.969
160 6.299
80 3.150
50 1.969
400 15.748
200 7.874
150 5.906
P.93
FX-410
FT-NFM2
50 1.969
25 0.984
16 0.630
24 0.945
12 0.472
8 0.315
16 0.630
8 0.315
5 0.197
P.93
FX-311
FT-NFM2S
50 1.969
25 0.984
16 0.630
24 0.945
12 0.472
8 0.315
16 0.630
8 0.315
5 0.197
P.93
FT-NFM2S4
50 1.969
25 0.984
16 0.630
24 0.945
12 0.472
8 0.315
16 0.630
8 0.315
5 0.197
P.93
FT-P2
36 1.417
18 0.709
14 0.551
20 0.787
10 0.394
8 0.315
18 0.709
9 0.354
7 0.276
P.93
FT-P40
32 1.260
13 0.512
12 0.472
18 0.709
9 0.354
7 0.276
14 0.551
7 0.276
5 0.197
P.93
FT-P60
50 1.969
25 0.984
18 0.709
26 1.024
13 0.512
8 0.315
20 0.787
10 0.394
7 0.276
P.93
FX-301-F7/
FX-301-F
P.93
Notes:1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with
varying humidity.
3) Sensing range when fiber length is 2 m 6.562 ft. When fiber length is 10 m 32.81 ft, the beam attenuates and cannot be used.
4) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set.
5) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
Digital Fiber Sensor
FX-300 SERIES
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
188
FIBER
SENSORS
LASER
SENSORS
Thru-beam type (One pair set)
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
PHOTOELECTRIC
SENSORS
Sensing range (mm in) (Note 1)
MICRO
PHOTOELECTRIC
SENSORS
FX-301B
Model No.
FX-301G
FAST
LONG
STD
FX-301H (Note 2)
FAST
LONG
STD
Dimensions
LONG
STD
FAST
FT-P80
130 5.118
65 2.559
45 1.772
70 2.756
35 1.378
25 0.984
56 2.205
28 1.102
20 0.787
P.93
FT-P81X
130 5.118
64 2.520
45 1.772
64 2.520
32 1.260
25 0.984
56 2.205
28 1.102
20 0.787
P.94
FT-PS1
14 0.551
7 0.276
4 0.157
6 0.236
3 0.118
2 0.079
14 0.551
7 0.276
4 0.157
P.93
FT-R80
85 3.346
42 1.654
28 1.102
44 1.732
22 0.866
16 0.630
32 1.260
16 0.630
12 0.472
P.94
FT-S20
55 2.165
28 1.102
18 0.709
28 1.102
13 0.512
9 0.354
25 0.984
13 0.512
9 0.354
P.94
FT-S21
50 1.969
25 0.984
16 0.630
24 0.945
12 0.472
8 0.315
23 0.906
11 0.433
8 0.315
P.94
FT-S30
155 6.102
76 2.992
45 1.772
90 3.543
40 1.575
26 1.024
80 3.150
43 1.693
27 1.063
P.94
FT-SFM2
FT-SFM2L
FT-SFM2SV2
FT-SNFM2
150 5.906
75 2.953
40 1.575
70 2.756
35 1.378
24 0.945
50 1.969
25 0.984
18 0.709
P.94
400 15.748
200 7.874
130 5.118
200 7.874
100 3.937
65 2.559
155 6.102
77 3.031
55 2.165
P.94
80 3.150
40 1.575
28 1.102
40 1.575
20 0.787
14 0.551
30 1.181
15 0.591
12 0.472
P.94
50 1.969
25 0.984
16 0.630
24 0.945
12 0.472
8 0.315
16 0.630
8 0.315
5 0.197
P.95
FT-T80
150 5.906
75 2.953
40 1.575
70 2.756
35 1.378
24 0.945
50 1.969
25 0.984
18 0.709
P.95
FT-V10
400 15.748
200 7.874
130 5.118
200 7.874
100 3.937
65 2.559
150 5.906
75 2.953
40 1.575
P.95
FT-V22
50 1.969
25 0.984
16 0.630
26 1.024
13 0.512
8 0.315
44 1.732
22 0.866
15 0.591
P.95
FT-V41
28 1.102
14 0.551
10 0.394
14 0.551
7 0.276
5 0.197
10 0.394
5 0.197
3 0.118
P.95
120 4.724
60 2.362
35 1.378
80 3.150
40 1.575
25 0.984
75 2.953
38 1.496
24 0.945
P.95
FT-V80Y
FT-W4
16 0.630
8 0.315
5 0.197
10 0.394
5 0.197
3 0.118
8 0.315
4 0.157
2.5 0.098
P.95
FT-W8
90 3.543
45 1.772
30 1.181
56 2.205
28 1.102
20 0.787
42 1.654
21 0.827
15 0.591
P.95
FT-WA8
600 23.622
300 11.811
220 8.661
300 11.811
150 5.906
110 4.331
220 8.661
110 4.331
80 3.150
P.95
FT-WA30
2,400 94.488
1,200 47.244
700 27.560
1,200 47.244
600 23.622
350 13.780
800 31.496
400 15.748
240 9.449
P.95
FT-WKV8
300 11.811
150 5.906
100 3.937
160 6.299
80 3.150
60 2.362
150 5.906
75 2.953
45 1.772
P.96
FT-WR80
90 3.543
45 1.772
30 1.181
56 2.205
28 1.102
20 0.787
48 1.890
22 0.866
14 0.551
P.96
240 9.449
120 4.724
90 3.543
120 4.724
60 2.362
40 1.575
42 1.654
P.96
FT-WR80L
FT-WS3
90 3.543
45 1.772
30 1.181
56 2.205
28 1.102
20 0.787
FT-WS4
16 0.630
8 0.315
5 0.197
10 0.394
5 0.197
3 0.118
FT-WS8
FT-WS8L
FT-WV42
132 5.197
–
8 0.315
65 2.559
–
4 0.157
–
2.5 0.098
P.96
P.96
90 3.543
45 1.772
30 1.181
56 2.205
28 1.102
20 0.787
42 1.654
21 0.827
15 0.591
P.96
240 9.449
120 4.724
90 3.543
120 4.724
60 2.362
40 1.575
110 4.331
55 2.165
35 1.378
P.96
–
–
–
–
–
–
–
–
–
P.96
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
FT-WZ4
35 1.378
15 0.591
9 0.354
18 0.709
8 0.315
4.8 0.189
43 1.693
15 0.591
9 0.354
P.96
FT-WZ4HB
32 1.260
15 0.591
9.6 0.378
16 0.630
9 0.354
5.4 0.213
40 1.575
15 0.591
12 0.472
P.97
FT-WZ7
80 3.150
40 1.575
24 0.945
54 2.216
27 1.063
16.2 0.638
54 2.126
27 1.063
16.2 0.638
P.97
100 3.937
50 1.969
30 1.181
56 2.205
28 1.102
16.8 0.661
56 2.205
28 1.102
16.8 0.661
P.97
FX-500
80 3.150
40 1.575
25 0.984
40 1.575
20 0.787
13 0.512
36 1.417
18 0.709
12 0.472
P.97
FX-100
FT-WZ8E
240 9.449
120 4.724
80 3.150
120 4.724
60 2.362
40 1.575
100 3.937
50 1.969
30 1.181
P.97
FX-300
FT-WZ8H
400 15.748
200 7.874
140 5.512
200 7.874
100 3.937
70 2.756
180 7.087
90 3.543
65 2.559
P.97
FX-410
120 4.724
60 2.362
40 1.575
60 2.362
30 1.181
22 0.866
46 1.811
23 0.906
16 0.630
P.97
FX-311
FT-Z8E
400 15.748
200 7.874
140 5.512
200 7.874
100 3.937
65 2.559
140 5.512
70 2.756
50 1.969
P.97
FT-Z8H
560 22.047
280 11.024
200 7.874
200 7.874
100 3.937
65 2.559
180 7.087
90 3.543
65 2.559
P.97
FT-Z802Y
320 12.598
160 6.299
120 4.724
160 6.299
80 3.150
60 2.362
320 12.598
160 6.299
120 4.724
P.97
FT-WZ7HB
FT-WZ8
FT-Z8
Notes:1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with
varying humidity.
Fibers
Amplifiers
FX-301-F7/
FX-301-F
189
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Digital Fiber Sensor
FX-300 SERIES
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
Retroreflective type
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
Sensing range (mm in) (Note 1, 2)
FX-301B
Model No.
FR-KV1
FX-301G
FX-301H
LONG
STD
FAST
LONG
STD
FAST
LONG
STD
FAST
–
–
–
–
–
–
–
–
–
P.98
20 to 70 0.787 to 2.756
–
P.98
20 to 90 0.787 to 3.543
–
–
P.98
100 to 340 3.937 to 13.386
–
–
P.98
FR-KZ21
20 to 200 0.787 to 7.874 20 to 120 0.787 to 4.724
20 to 90 0.787 to 3.543 20 to 130 0.787 to 5.118
20 to 80 0.787 to 3.150
FR-KZ21E
20 to 160 0.787 to 6.299 20 to 100 0.787 to 3.937
20 to 60 0.787 to 2.362 20 to 110 0.787 to 4.331
–
–
–
–
FR-WKZ11
Dimensions
–
–
–
–
20 to 50 0.787 to 1.969 20 to 130 0.787 to 5.118
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for
the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head.
If this occurs, adjust the threshold value of the amplifier unit before use.
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
Reflective type
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
Sensing range (mm in) (Note 1, 2)
FX-301B
Model No.
LONG
FD-30
FD-31
FD-40
FD-41
FD-60
FD-61
FD-A15
FD-AFM2
FD-AFM2E
FD-B8
FD-E12
FD-E22
FD-EG1
FD-EG2
FD-EG3
FD-EN500S1
FD-ENM1S1
FD-F4
FD-F41
FD-F41Y
FD-F8Y
FD-FA90
FD-FM2
FD-FM2S
FD-FM2S4
FD-G4
FD-G6
FD-G6X
FD-G40
FD-G60
FD-H13-FM2
FD-H18-L31
FD-H20-21
FD-H20-M1
STD
FX-301G
FAST
LONG
FX-301H
STD
FAST
LONG
STD
Dimensions
FAST
19 0.748
9 0.354
6 0.236
9 0.354
4.5 0.177
2.5 0.098
8 0.315
4 0.157
2.5 0.098
P.99
18 0.709
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
7 0.276
3 0.118
2 0.079
P.99
19 0.748
9 0.354
6 0.236
9 0.354
4.5 0.177
2.5 0.098
8 0.315
4 0.157
2.5 0.098
P.99
18 0.709
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
7 0.276
3 0.118
2 0.079
P.99
55 2.165
28 1.102
18 0.709
30 1.181
15 0.591
10 0.394
30 1.181
15 0.591
10 0.394
P.99
48 1.890
24 0.945
16 0.630
26 1.024
13 0.512
8 0.315
27 1.063
12 0.472
8 0.315
25 0.984
15 0.591
40 1.575
20 0.787
13 0.512
18 0.709
9 0.354
5 0.197
12 0.472
6 0.236
4 0.157
P.99
40 1.575
20 0.787
13 0.512
18 0.709
9 0.354
5 0.197
12 0.472
6 0.236
4 0.157
P.99
80 3.150
40 1.575
26 1.024
42 1.654
21 0.827
14 0.551
26 1.024
13 0.512
9 0.354
2 0.079
1 0.039
6 0.236
3 0.118
2 0.079
3 0.118
1.5 0.059
1 0.039
6 0.236
3 0.118
2 0.079
6 0.236
3 0.118
2 0.079
3 0.118
1.5 0.059
1 0.039
10 0.394
5 0.197
3 0.118
P.100
5 0.197
2 0.079
1 0.039
2 0.079
1 0.039
6 0.236
3 0.118
2 0.079
P.100
2 0.079
–
1 0.039
–
–
–
–
–
–
1 0.039
1 0.039
–
–
–
–
–
–
–
–
–
–
–
1 0.039
3 0.118
–
–
–
1.5 0.059
–
–
–
1 0.039
–
6 0.236
3 0.118
2 0.079
3 0.118
1.5 0.059
1 0.039
4 0.157
2 0.079
1.5 0.059
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
ø4 mm ø0.157 in form Protective tube: fluorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
–
–
–
–
–
–
–
–
–
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe (When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in) [PFA (fluorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
46 1.811
23 0.906
15 0.591
24 0.945
12 0.472
8 0.315
20 0.787
10 0.394
7 0.276
46 1.811
23 0.906
15 0.591
24 0.945
12 0.472
8 0.315
20 0.787
46 1.811
23 0.906
15 0.591
24 0.945
12 0.472
8 0.315
20 0.787
22 0.866
11 0.433
8 0.315
12 0.472
6 0.236
4 0.157
7 0.276
22 0.866
11 0.433
8 0.315
12 0.472
6 0.236
4 0.157
7 0.276
33 1.299
11 0.433
6 0.236
12 0.472
6 0.236
4 0.157
22 0.866
11 0.433
8 0.315
12 0.472
6 0.236
46 1.811
23 0.906
15 0.591
24 0.945
20 0.787
11 0.433
7 0.276
20 0.787
–
–
–
–
P.99
P.100
P.100
P.100
P.100
P.100
P.100
P.100
P.101
P.101
P.101
P.101
7 0.276
P.101
10 0.394
7 0.276
P.101
3.5 0.138
2 0.079
P.101
3.5 0.138
2 0.079
P.102
7 0.276
3.5 0.138
2 0.079
P.102
4 0.157
7 0.276
3.5 0.138
2 0.079
P.101
12 0.472
8 0.315
20 0.787
10 0.394
7 0.276
P.102
11 0.433
7 0.276
25 0.984
12 0.472
8 0.315
–
–
–
10 0.394
P.99
P.99
–
–
P.102
P.102
36 1.417
18 0.709
12 0.472
20 0.787
10 0.394
7 0.276
140 5.512
70 2.756
45 1.772
P.102
36 1.417
18 0.709
12 0.472
20 0.787
10 0.394
7 0.276
140 5.512
70 2.756
45 1.772
P.102
Notes:1) The standard sensing objects of the sensing ranges vary depending on the fibers.
2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Digital Fiber Sensor
FX-300 SERIES
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
FIBER
SENSORS
Reflective type
LASER
SENSORS
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber.
PHOTOELECTRIC
SENSORS
Sensing range (mm in) (Note 1, 2)
FX-301B
Model No.
LONG
–
FD-H25-L43
–
FD-H25-L45
FD-H30-KZ1V-S (Note 3) 30 to 40 1.181 to 1.575
–
FD-H30-L32
–
FD-H30-L32V-S (Note 3)
22 0.866
FD-H35-20S
36 1.417
FD-H35-M2
36 1.417
FD-H35-M2S6
FD-HF40Y
FD-L4
FD-L41
FD-L43
FD-L44
FD-L44S
FD-L45
FD-L45A
FD-L46
FD-L47
FD-NFM2
FD-NFM2S
FD-NFM2S4
FD-P2
FD-P40
FD-P50
FD-P60
FD-P80
FD-P81X
FD-R80
FD-S30
FD-S31
FD-S80
FD-SFM2SV2
FD-SNFM2
FD-T40
FD-T80
FD-V41
FD-W8
FD-W44
FD-WG4
FD-WKZ1
FD-WL41
FD-WL48
FD-WS8
FD-WSG4
FD-WT4
FD-WT8
FD-WV42
FD-WZ4
FD-WZ4HB
FD-WZ7
FD-WZ7HB
190
FX-301G
FX-301H
Dimensions
STD
FAST
LONG
STD
FAST
LONG
STD
FAST
–
–
–
–
–
–
–
–
P.103
–
–
–
–
–
–
–
–
P.103
–
–
–
–
–
–
–
–
P.103
–
–
–
–
–
–
–
–
P.103
–
–
–
–
–
–
–
–
P.103
11 0.433
7 0.276
12 0.472
6 0.236
4 0.157
80 3.150
40 1.575
28 1.102
P.104
18 0.709
12 0.472
20 0.787
10 0.394
7 0.276
140 5.512
70 2.756
45 1.772
P.104
18 0.709
12 0.472
20 0.787
10 0.394
7 0.276
140 5.512
70 2.756
45 1.772
ø4 mm ø0.157 in form Protective tube: fluorine resin, length:500 mm 19.685 in (allowable cutting)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
4.5 to 9.5 0.177 to 0.374 5 to 9 0.197 to 0.354 5.5 to 8 0.217 to 0.315 5 to 9 0.197 to 0.354 5.5 to 8 0.217 to 0.315 – 4.5 to 9.5 0.177 to 0.374 –
–
(Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236) (Convergent point 6 0.236)
(Convergent point 6 0.236)
–
–
–
–
–
–
–
–
–
P.104
–
–
–
–
–
–
–
P.104
–
–
P.104
–
–
1 to 4.3 0.039 to 0.169
–
–
P.104
–
–
–
–
–
–
P.104
–
–
–
–
–
–
P.105
–
–
–
–
–
–
–
P.105
–
–
–
–
–
–
–
P.105
–
1 to 3 0.039 to 0.118
–
–
–
–
–
–
–
–
–
–
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SIMPLE
WIRE-SAVING
UNITS
P.104
–
1 to 3 0.039 to 0.118
PRESSURE /
FLOW
SENSORS
P.104
1 to 4.3 0.039 to 0.169
0 to 3.5 0 to 0.138
LIGHT
CURTAINS
SENSOR
OPTIONS
–
1 to 4.5 0.039 to 0.177 1.5 to 3.8 0.059 to 0.150 1 to 4.6 0.039 to 0.181 2.5 to 3 0.098 to 0.118
AREA
SENSORS
P.104
–
0 to 5.7 0 to 0.224
MICRO
PHOTOELECTRIC
SENSORS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
16 0.630
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
6 0.236
3 0.118
2 0.079
P.105
16 0.630
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
6 0.236
3 0.118
2 0.079
P.105
16 0.630
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
6 0.236
3 0.118
2 0.079
P.105
8 0.315
4 0.157
2.5 0.098
4 0.157
2 0.079
1.5 0.059
7 0.276
3.5 0.138
5 0.197
2.5 0.098
1.5 0.059
3 0.118
1.5 0.059
1 0.039
2 0.079
1 0.039
20 0.787
10 0.394
6 0.236
10 0.394
5 0.197
3 0.118
8 0.315
4 0.157
2.5 0.098
P.105
20 0.787
10 0.394
6 0.236
10 0.394
5 0.197
3 0.118
8 0.315
4 0.157
2.5 0.098
P.105
40 1.575
20 0.787
13 0.512
20 0.787
10 0.394
7 0.276
18 0.709
9 0.354
6 0.236
P.105
32 1.260
16 0.630
10 0.394
16 0.630
8 0.315
5 0.197
18 0.709
9 0.354
6 0.236
P.106
32 1.260
16 0.630
10 0.394
16 0.630
8 0.315
5 0.197
10 0.394
5 0.197
3 0.118
P.106
19 0.749
9 0.354
6 0.236
9 0.354
4.5 0.177
2.5 0.098
8 0.315
4 0.157
2.5 0.098
P.106
18 0.709
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
7 0.276
3 0.118
2 0.079
P.106
46 1.811
23 0.906
15 0.591
24 0.945
12 0.472
8 0.315
20 0.787
14 0.551
7 0.276
4 0.157
7 0.276
3.5 0.138
16 0.630
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
6 0.236
3 0.118
2 0.079
P.106
16 0.630
8 0.315
5 0.197
8 0.315
4 0.157
2 0.079
6 0.236
3 0.118
2 0.079
P.106
Selection
Guide
46 1.811
23 0.906
15 0.591
24 0.945
7 0.276
P.106
Fibers
P.106
Amplifiers
–
3 0.118
12 0.472
–
–
8 0.315
–
4 0.157
20 0.787
–
10 0.394
–
10 0.394
–
6 0.236
3 0.118
23 0.906
11 0.433
8 0.315
14 0.551
7 0.276
4 0.157
11 0.433
5.5 0.217
5 0.197
2.5 0.098
1.5 0.059
3 0.118
1.5 0.059
1 0.039
2 0.079
1 0.039
11 0.433
5 0.197
3 0.118
6 0.236
3 0.118
2 0.079
5 0.197
2.5 0.098
2 0.079
–
7 0.276
–
–
3 0.118
–
1.5 0.059
P.105
P.105
P.106
P.107
P.107
–
–
–
–
–
–
–
P.107
–
–
–
–
–
–
–
–
–
P.107
–
–
–
–
–
–
0.5 to 3.5 0.020 to 0.138
–
–
P.107
23 0.906
11 0.433
8 0.315
14 0.551
7 0.276
4 0.157
11 0.433
5.5 0.217
3 0.118
P.107
11 0.433
5 0.197
3 0.118
6 0.236
3 0.118
2 0.079
5 0.197
2.5 0.098
1.5 0.059
P.107
5 0.197
2.5 0.098
1.5 0.059
3 0.118
1.5 0.059
1 0.039
2 0.079
1 0.039
23 0.906
11 0.433
8 0.315
14 0.551
7 0.276
4 0.157
11 0.433
5.5 0.217
–
–
–
–
–
–
P.107
P.107
–
–
–
P.108
–
–
–
–
–
–
5 to 8 0.197 to 0.315
–
–
P.108
4 to 9 0.157 to 0.354
–
–
–
–
–
4 to 12 0.157 to 0.472
–
–
P.108
4 to 15 0.157 to 0.591
–
–
–
–
–
5 to 8 0.197 to 0.315
–
–
P.108
3 to 28 0.118 to 1.102
3 to 14 0.118 to 0.551
4 to 8.4 0.157 to 0.331
3 to 16 0.118 to 0.630
4 to 8 0.157 to 0.315
4.8 0.189 3 to 18 0.118 to 0.709
–
–
P.108
Notes:1) The standard sensing objects of the sensing ranges vary depending on the fibers.
2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
3) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
P.107
–
3 0.118
PLC /
TERMINALS
P.106
–
–
LASER
MARKERS
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
191
Digital Fiber Sensor
FIBER OPTIONS
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
FX-300 SERIES
Lens (for thru-beam type fiber)
Designation
Model No.
Description
MICRO
PHOTOELECTRIC
SENSORS
Sensing range for red LED type (mm) [Lens on both sides] (Note 3)
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
Expansion
lens
(Note 1)
INDUCTIVE
PROXIMITY
SENSORS
FX-LE1
PARTICULAR
USE
SENSORS
FX-311
FX-301-F7/
FX-301-F
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,500
1,300
1,000
FT-R80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,300
1,600
800
750
FT-W8
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,900
2,000
1,000
900
FT-P80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,500
1,100
1,000
FT-P60
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
1,500
900
800
• Ambient
temperature:
–60 to +350 °C
–76 to +662 °F
(Note 5)
For thru-beam type fiber
Superexpansion
lens
(Note 1)
Tremendously
increases the sensing
range with large
diameter lenses.
FX-LE2
FT-P81X 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
2,500
2,000
1,300
1,100
950
1,500
750
700
900
500
400
1,100
900
600
• Ambient
temperature:
–60 to +350 °C
–76 to +662 °F
(Note 5)
Mode
U-LG LONG STDF
STD
FAST
S-D
H-SP
FT-B8
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-FM2
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-R80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-W8
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-P80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-P60
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-P81X 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
FT-H35-M2 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-H20W-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
1,500
1,600 (Note 2)
FT-H20-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
FT-H13-FM2 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
Sensing range for red LED type (mm) [Lens on both sides] (Note 3)
Beam axis is bent by
90°.
Side-view
lens
FX-SV1
Expansion
lens for
vacuum
fiber
(Note 1)
Vacuum
resistant
side-view
lens
(Note 1)
• Ambient
temperature:
–60 to +300 °C
–76 to +572 °F
(Note 5)
Mode
STD
FAST
S-D
FT-B8
1,450
1,100
660
530
400
186
180
FT-FM2
1,800
1,200
810
600
440
210
210
Fiber
Amplifiers
FX-410
1,000
FT-T80
Fiber
Fibers
FX-300
1,300
Sensing range for red LED type (mm) [Lens on both sides] (Note 3)
Selection
Guide
FX-100
2,500
FT-H20-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
MACHINE
VISION
SYSTEMS
FX-500
1,000
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-FM2
FA
COMPONENTS
UV
CURING
SYSTEMS
H-SP
1,000
3,000
FT-H20W-M1 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
STATIC
CONTROL
DEVICES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
S-D
2,000
FT-H35-M2 3,500 (Note 2) 3,500 (Note 2)
MEASUREMENT
SENSORS
HUMAN
MACHINE
INTERFACES
FAST
Increases the sensing
range by 5 times or
more.
WIRE-SAVING
SYSTEMS
PLC /
TERMINALS
STD
3,500 (Note 2) 3,500 (Note 2)
SIMPLE
WIRE-SAVING
UNITS
LASER
MARKERS
U-LG LONG STDF
FT-B8
SENSOR
OPTIONS
ENDOSCOPE
Mode
2,500
Fiber
U-LG LONG STDF
H-SP
FT-T80
1,800
1,200
810
600
440
210
210
FT-W8
1,300
900
600
450
330
160
160
FT-P80
1,800
1,200
810
600
440
210
210
FT-P60
850
650
400
300
200
130
120
FT-P81X
1,800
1,200
810
600
440
200
200
FT-H35-M2
840
550
370
280
200
90
90
FT-H20W-M1
400
310
180
140
100
50
50
FT-H20-M1
840
550
370
280
200
90
90
FV-LE1
Sensing range increases Sensing range for red LED type (mm) [Lens on both sides] (Note 3, 4)
by 4 times or more.
Mode
U-LG LONG STDF STD FAST S-D
H-SP
• Ambient temperature: Fiber
–60 to +350 °C
FT-H30-M1V-S 1,600
1,200
650
450
300
150
200
–76 to +662 °F (Note 5)
FV-SV2
Beam axis is bent by Sensing range for red LED type (mm) [Lens on both sides] (Note 3, 4)
90°.
Mode
U-LG LONG STDF STD FAST S-D
H-SP
• Ambient temperature: Fiber
–60 to +300 °C
FT-H30-M1V-S 1,600
1,200
650
450
300
150
200
–76 to +572 °F (Note 5)
Notes:1) B
e careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult.
Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have
adjusted it sufficiently.
2) T
he fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long (FT-P81X, FT-H20W-M1 and FT-H20-M1: 1,600 mm 62.992 in).
3) T
he sensing ranges are the values for red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifiers.
4) T
he fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in U-LG and LONG modes take into account the length of the FT-J8
atmospheric side fiber.
5) Refer to p.76~ for the ambient temperatures of fibers to be used in combination.
Digital Fiber Sensor
FX-300 SERIES
192
FIBER OPTIONS
FIBER
SENSORS
Lens (for reflective type fiber)
Designation
Pinpoint
spot lens
LASER
SENSORS
Model No.
Pinpoint spot of ø0.5 mm ø0.020 in. Enables detection of minute objects or small marks.
• Distance to focal point: 6 ±1 mm 0.236 ±0.039 in
• Applicable fibers: FD-WG4, FD-G4
• Ambient temperature: – 40 to +70 °C – 40 to +158 °F (Note 2)
FX-MR1
The spot diameter is adjustable Sensing range for red LED type (Note 1)
from ø0.7 to ø2 mm ø0.028 to
ø0.079 in according to how
Distance to focal point
Screw-in depth
much the fiber is screwed in.
7 mm 0.276 in
ø18.5 mm ø0.728 in approx.
• Applicable fibers:
FD-WG4, FD-G4
12
mm
0.472
in
ø27 mm ø1.063 in approx.
• Ambient temperature:
Spot
– 40 to +70 °C
ø43 mm ø1.693 in approx.
14 mm 0.551 in
diameter
– 40 to +158 °F (Note 2)
• Accessory: MS-EX-3
(mounting bracket)
Screw-in
depth
For reflective type fiber
Zoom lens
Finest
spot lens
FX-MR2
Distance to
focal point
FX-MR3
Distance to
focal point
Spot diameter
Finest spot
lens
FX-MR6
Screw-in depth
Zoom lens
Side-view
type
FX-MR5
PHOTOELECTRIC
SENSORS
Description
Distance
to focal
point
Spot diameter
Extremely fine spot of ø0.3 mm
ø0.012 in approx. achieved.
• Applicable fibers:
FD-WG4, FD-G4,
FD-EG1, FD-EG2,
FD-EG3, FD-G6X,
FD-G6
• Ambient temperature:
– 40 to +70 °C
– 40 to +158 °F (Note 2)
Sensing range for red LED type (Note 1)
Extremely fine spot of ø0.1 mm
ø0.004 in approx. achieved.
• Applicable fibers:
FD-WG4, FD-G4,
FD-EG1, FD-EG2,
FD-EG3, FD-G6X,
FD-G6
• Ambient temperature:
–20 to +60 °C
– 4 to +140 °F (Note 2)
Sensing range for red LED type (Note 1)
Distance to focal point
Fiber
Spot diameter
ø0.7 mm ø0.028 in
ø1.2 mm ø0.047 in
ø2.0 mm ø0.079 in
Spot diameter
7.5 ±0.5 mm 0.295 ±0.020 in ø0.15 mm ø0.006 in approx
7.5 ±0.5 mm 0.295 ±0.020 in ø0.2 mm ø0.008 in approx
FD-EG1
7.5 ±0.5 mm 0.295 ±0.020 in ø0.3 mm ø0.012 in approx
FD-WG4/G4/G6X/G6 7.5 ±0.5 mm 0.295 ±0.020 in ø0.5 mm ø0.020 in approx
Spot diameter
FD-EG3
7 ±0.5 mm 0.276 ±0.020 in ø0.1 mm ø0.004 in approx
FD-EG2
7 ±0.5 mm 0.276 ±0.020 in ø0.15 mm ø0.006 in approx
FD-EG1
7 ±0.5 mm 0.276 ±0.020 in ø0.2 mm ø0.008 in approx
FD-WG4/G4/G6X/G6 7 ±0.5 mm 0.276 ±0.020 in ø0.4 mm ø0.016 in approx
FX-MR2 is converted into a
Sensing range for red LED type (Note 1)
side-view type and can be
Screw-in depth
Distance to focal point
mounted in a very small space.
• Applicable fibers:
13 mm 0.512 in approx.
8 mm 0.315 in
FD-WG4, FD-G4
15 mm 0.591 in approx.
10 mm 0.394 in
• Ambient temperature:
– 40 to +70 °C
30 mm 1.181 in approx.
14 mm 0.551 in
– 40 to +158 °F (Note 2)
Spot diameter
ø0.5 mm ø0.020 in
ø0.8 mm ø0.031 in
ø3.0 mm ø0.118 in
Notes:1) The sensing ranges are the values when used in combination with red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifier.
2) Refer p.76~ for the ambient temperatures of fibers to be used in combination.
Others
Designation
Model No.
Description
FTP-500 (0.5 m 1.641 ft)
For
M4
Protective tube FTP-1500 (1.5 m 4.922 ft) thread
(For thru-beam
FTP-N500 (0.5 m 1.641 ft) For
type fiber)
FTP-N1000 (1 m 3.281 ft) M3
FTP-N1500 (1.5 m 4.922 ft) thread
FT-42
FT-B8
FT-FM2
FT-FM2S
FDP-500 (0.5 m 1.641 ft)
For
FDP-1000 (1 m 3.281 ft) M6
Protective tube FDP-1500 (1.5 m 4.922 ft) thread
(For reflective
FDP-N500 (0.5 m 1.641 ft) For
type fiber)
FDP-N1000 (1 m 3.281 ft) M4
FDP-N1500 (1.5 m 4.922 ft) thread
Fiber bender FB-1
MS-AJ1-F
Universal sensor
mounting stand (Note 2) MS-AJ2-F
Single core
FX-AT15A
holder
Applicable fibers
FTP-1000 (1 m 3.281 ft)
FT-FM2S4
FT-H13-FM2
FT-P60
FT-P80
The protective
FT-31
FT-P40
tube, made of
FT-NFM2
FT-T80
noncorrosive
FT-NFM2S FD-P40
stainless steel,
FT-NFM2S4 FD-T40
protects the
FD-61
FD-FM2S4 inner fiber
FD-B8
FD-H13-FM2
cable from
FD-FM2
FD-P80
any external
FD-FM2S
forces.
FD-41
FD-T80
FD-NFM2
FD-NFM2S
FD-NFM2S4
The fiber bender bends the sleeve part of the
fiber head at the proper radius. (Note 1)
Horizontal mounting type Mounting stand assembly for fiber
Vertical mounting type (For M3,M4 or M6 threaded head fiber)
The incident light intensity may vary when using a multi-core fiber or a thin type sharp
bending fiber. This holder suppresses the variation in the incident light intensity. Brown.
Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber.
2) Refer to the universal sensor mounting stand MS-AJ series pages for details.
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
FD-EG3
Distance to focal point
AREA
SENSORS
LIGHT
CURTAINS
FD-EG2
Fiber
MICRO
PHOTOELECTRIC
SENSORS
Protective tube
Fiber bender
•FTP-□
•FDP-□
•FB-1
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Universal sensor mounting stand
Using the arm which enables adjustment in the horizontal direction,
sensing can also be done from above an assembly line.
Swivel: 360° rotation
•MS-AJ1-F
20°
Mounting hole for M6 screw
20°
Angle adjustment: ±20°
Swivel: 360° rotation
Forward / back adjustment:
130 mm 5.118 in approx
Single core holder
•FX-AT15A
Height adjustment:
150 mm 5.906 in approx.
360°
FX-100
FX-410
Height adjustment:
150 mm 5.906 in approx.
•MS-AJ2-F
FX-500
FX-300
Forward / back adjustment:
130 mm 5.118 in approx
360°
Amplifiers
20°
20°
Angle adjustment: ±20°
Mounting hole for M6 screw
FX-311
FX-301-F7/
FX-301-F
193
Digital Fiber Sensor
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Type
AREA
SENSORS
Model No.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
FX-300 SERIES
Item
FX-301
FX-301B
FX-301G
FX-301H
FX-301-HS
FX-305
FX-301BP
FX-301GP
FX-301HP
FX-301P-HS
FX-305P
Power consumption
Output
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
ENDOSCOPE
Response time
Sensitivity setting
PLC /
TERMINALS
Digital display
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
Selectable either Light-ON or Dark-ON, with jog switch
Incorporated
35 µs or less (H-SP),
65 µs or less [H-SP (Red LED type only)], 150 µs or less (FAST), 150 µs or less (FAST),
250 µs or less [STD / S-D (Red LED type only)],
250 µs or less (STD / S-D),
2 ms or less (LONG),
2 ms or less (LONG), selectable with jog switch
selectable with jog switch
Timer function
Light emitting amount
selection function
Automatic interference
prevention function
Ambient temperature
65 µs or less (H-SP), 150 µs or less (FAST),
250 µs or less (STD), 700 µs or less (STDF),
2.5 ms or less (LONG), 4.5 ms or less (U-LG),
selectable with jog switch
Normal mode: 2-point teaching / Limit teaching / Full-auto teaching /
Max. sensitivity teaching / Manual adjustment
Window comparator mode: Teaching (1-point / 2-point / 3-point) / Manual adjustment
2-point teaching / Limit teaching / Manual adjustment /
Full-auto teaching / Max. sensitivity teaching
Orange LED (lights up when the output is ON)
–
Green LED (lights up under stable light received condition or stable dark condition)
RUN: Green LED, TEACH • ADJ • L/D ON • TIMER • PRO: Yellow LED
4 digit red LED display
Fine sensitivity adjustment function
Incorporated
Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer,
switchable either effective or ineffective.
Timer period: Red LED type; 0.5 ms approx., 1 to 9999 ms
(Blue LED, Green LED, Infrared LED type; approx. 0.5 to 500 ms)
Incorporated (Red LED type only) (Note 3)
FAST, STD, LONG: 4 level, H-SP: 3 level, S-D: 2 level
Incorporated (Up to four sets of fiber heads can be mounted
close together. However, H-SP mode is 2 fiber heads.) (Note 4)
Incorporated with variable ON-delay / OFF-delay /
ONE SHOT / ON-delay • OFF-delay / ON-delay • ONE SHOT
timer, switchable either effective or ineffective.
(Timer period: Output 1; 0.5 ms, 1 to 9999 ms, Output 2; 0.5 ms, 1 to 500 ms)
Incorporated (Note 3)
FAST, STD, LONG: 4 level
H-SP, S-D: 2 level
Incorporated (Note 3)
FAST, STD, STDF, LONG, U-LG: 4 level
H-SP: 3 level
–
Incorporated [Up to four sets of fiber heads can be
mounted close together. (However, U-LG mode is 8
fiber heads, H-SP mode is 2 fiber heads.)] (Note 5)
–10 to +55 °C +14 to +131 °F (If 4 to 7 units are connected in cascade: –10 to +50 °C +14 to +122 °F, if 8 to 16 units are
connected in cascade: –10 to +45 °C +14 to +113 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C – 4 to +158 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Incandescent light: 3,000 ℓx at the light-receiving face
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 6)
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 6)
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance
Emitting element (modulated)
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Red LED
Blue LED
Green LED
Infrared LED
Red LED
Red LED
Peak emission wavelength 650 nm 0.026 mil 470 nm 0.019 mil 525 nm 0.021 mil 940 nm 0.037 mil 650 nm 0.026 mil
Material
FX-410
Connecting method
FX-311
Cable length
FX-301-F7/
FX-301-F
<PNP output type>
<PNP output type>
PNP open-collector transistor 2 outputs
PNP open-collector transistor
• Maximum source current: 50 mA each (Note 2)
• Maximum source current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade.)
• Applied voltage: 30 V DC or less (between output and +V)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less [at 50 mA (Note 2)]
• Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) source current.]
MODE indicator
Environmental resistance
FA
COMPONENTS
<NPN output type>
<NPN output type>
NPN open-collector transistor
NPN open-collector transistor 2 outputs
• Maximum sink current:100 mA (50 mA, if five, or more, amplifiers are connected in cascade.)
• Maximum sink current: 50 mA each (Note 2)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) sink current.]
• Residual voltage: 1.5 V or less [at 50 mA (Note 2)]
Operation indicator
Stability indicator
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
<Red LED / Infrared LED type>
<Blue LED / Green LED type>
Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
ECO mode: 430 mW or less (Current consumption 18 mA or less at 24 V supply voltage)
Short-circuit protection
LASER
MARKERS
HUMAN
MACHINE
INTERFACES
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Output operation
WIRE-SAVING
SYSTEMS
STATIC
CONTROL
DEVICES
High-function type
FX-301P
Supply voltage
SIMPLE
WIRE-SAVING
UNITS
High-speed
Green LED Infrared LED type
PNP output
PRESSURE /
FLOW
SENSORS
MEASUREMENT
SENSORS
Blue LED
NPN output
LIGHT
CURTAINS
INDUCTIVE
PROXIMITY
SENSORS
Standard type
Red LED
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, MODE key: Acrylic, Jog switch: Heat-resistant ABS (FX-301B/G/H: Acrylic)
Connector (Note 7)
Total length up to 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable.
Weight
Accessory
650 nm 0.026 mil
Net weight: 20 g approx., Gross weight: 25 g approx.
FX-MB1 (amplifier
protection seal): 1 set
–
FX-MB1 (amplifier protection seal): 1 set
Notes:1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2)50 mA per output. 25 mA if five, or more, amplifiers are connected in cascade.
3)The light emitting amount can be zero (emission halt) in all modes.
4)When the power supply is switched on, the light emission timing is automatically set for interference prevention.
5)When the interference prevention function “
” is set, the number of mountable fiber heads becomes double.
Furthermore, take care that the response time also becomes double.
6)The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
7)The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cables given below.
Main cable (3-core) for FX-301(P)(-HS): CN-73-C1 (Cable length 1 m 3.281 ft), CN-73-C2 (Cable length 2 m 6.562 ft), CN-73-C5 (Cable length 5 m 16.404 ft)
Sub cable (1-core) for FX-301(P)(-HS): CN-71-C1 (Cable length 1 m 3.281 ft), CN-71-C2 (Cable length 2 m 6.562 ft), CN-71-C5 (Cable length 5 m 16.404 ft)
Main cable (4-core) for FX-305(P): CN-74-C1 (Cable length 1 m 3.281 ft), CN-74-C2 (Cable length 2 m 6.562 ft), CN-74-C5 (Cable length 5 m 16.404 ft)
Sub cable (2-core) for FX-305(P): CN-72-C1 (Cable length 1 m 3.281 ft), CN-72-C2 (Cable length 2 m 6.562 ft), CN-72-C5 (Cable length 5 m 16.404 ft)
Digital Fiber Sensor
FX-300 SERIES
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
FX-301(-HS)
NPN output type
I/O circuit diagram
Sensor circuit
D
1
3
Tr
Terminal No.
(Brown) +V (Note 1)
(Black) Output
2
Load
+
–
Load
Black
12 to 24 V DC
±10 %
+
Users’ circuit
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 50 mA max., if five amplifiers, or more, are connected together.
Sensor circuit
1
ZD
INDUCTIVE
PROXIMITY
SENSORS
1
+V
3
Output
2
0V
PARTICULAR
USE
SENSORS
Tr
3
D
2
+
–
(Black) Output
+
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 50 mA max., if five amplifiers, or more, are connected together.
–
Load
Blue (Note)
Terminal arrangement diagram
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
1
+V
3
Output
2
0V
D
1
Tr1
3
Tr2
ZD1
4
ZD2
2
Terminal No.
Wiring diagram
Color code of quick-connection cable
Load
(Black) Output
Load
(White) Output 2 50 mA max. (Note 2)
+
–
Load
Load
+
–
White
50 mA max. (Note 2)
Users’ circuit
12 to 24 V DC
±10 %
Fibers
1
+V
3
Output 1
2
0V
Amplifiers
4
Output 2
FX-500
PNP output type
Terminal No.
4
(Brown) +V (Note 1)
50 mA max. (Note 2)
D
Internal circuit
2
(White) Output 2
Color code of quick-connection cable
Brown (Note)
ZD2 (Black) Output 1 50 mA max. (Note 2)
Tr2
Wiring diagram
Color code of quick-connection cable
3
Tr1
UV
CURING
SYSTEMS
Selection
Guide
FX-305P
1
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
Terminal arrangement diagram
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
ZD1
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Note: T
he quick-connection sub cable does not have brown lead wire and
blue lead wire.
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 25 mA max., if five amplifiers, or more, are connected together.
I/O circuit diagram
ENDOSCOPE
Blue (Note)
(Blue) 0 V (Note 1)
Internal circuit
Color code of quick-connection cable
Black
12 to 24 V DC
±10 %
STATIC
CONTROL
DEVICES
HUMAN
MACHINE
INTERFACES
Brown (Note)
(Brown) +V (Note 1)
MEASUREMENT
SENSORS
PLC /
TERMINALS
NPN output type
I/O circuit diagram
SIMPLE
WIRE-SAVING
UNITS
LASER
MARKERS
FX-305
Sensor circuit
12 to 24 V DC
±10 %
Note: T
he quick-connection sub cable does not have brown lead wire and
blue lead wire.
Users’ circuit
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
Black
12 to 24 V DC
±10 %
Load
(Blue) 0 V (Note 1)
Internal circuit
Color code of quick-connection cable
Brown (Note)
(Brown) +V (Note 1)
100 mA max. (Note 2)
AREA
SENSORS
PRESSURE /
FLOW
SENSORS
Wiring diagram
Color code of quick-connection cable
MICRO
PHOTOELECTRIC
SENSORS
Terminal arrangement diagram
PNP output type
Terminal No.
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS
FX-301P(-HS)
I/O circuit diagram
LASER
SENSORS
Note: T
he quick-connection sub cable does not have brown lead wire and
blue lead wire.
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
Sensor circuit
12 to 24 V DC
±10 %
–
Blue (Note)
(Blue) 0 V (Note 1)
Internal circuit
Color code of quick-connection cable
Brown (Note)
100 mA max. (Note 2)
ZD
Wiring diagram
Color code of quick-connection cable
194
Load
Load
+
–
(Blue) 0 V (Note 1)
Users’ circuit
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 25 mA max., if five amplifiers, or more, are connected together.
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : PNP output transistor
+
White
Load
Load
–
12 to 24 V DC
±10 %
Blue (Note)
Note: T
he quick-connection sub cable does not have brown lead wire and
blue lead wire.
Terminal arrangement diagram
1
+V
3
Output 1
2
0V
FX-300
FX-410
FX-311
Black
12 to 24 V DC
±10 %
FX-100
4
Output 2
FX-301-F7/
FX-301-F
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
Thru-beam type Parallel deviation
PHOTOELECTRIC
SENSORS
FT-A8 FT-WA8
MICRO
PHOTOELECTRIC
SENSORS
Horizontal direction
PARTICULAR
USE
SENSORS
ENDOSCOPE
LASER
MARKERS
400
15.748
UV
CURING
SYSTEMS
Selection
Guide
Fibers
STDF
STD
H-SP
0
200
7.874
100
0
100
3.937
3.937
Down
Up
Center
Operating point ℓ (mm in)
FT-P81X
Thru-beam type
STD
H-SP
500
19.685
ℓ
0
800
31.496
200
7.874
Fiber
head
L
Fiber
head
FT-W4 FT-WS4 Thru-beam type
ℓ
Fiber
head
L
Fiber
head
800
31.496
White non-glossy paper
ℓ
L
Fiber
U-LG
head
600
23.662
STDF
400
15.748
200
7.874
Amplifiers
Reflective type
STD
H-SP
0
100
3.937
FX-500
STD
0
400
15.748
100
0
100
200
3.937
3.937
7.874
Left
Right
Center
Operating point ℓ (mm in)
FD-B8
STDF
H-SP
U-LG
ℓ
Fiber
head
L
Fiber
head
STD
100
3.937
H-SP
0
40
1.575
200
0
200
400
7.874
7.874 15.748
Left
Right
Center
Operating point ℓ (mm in)
ℓ
Fiber
head
L
Fiber
head
L
Fiber
head
U-LG
H-SP
0
400
15.748
STD
200
0
200
400
7.874
7.874 15.748
Left
Right
Center
Operating point ℓ (mm in)
FT-W8 FT-WS8 Thru-beam type
U-LG
600
23.662
STDF
Fiber
head
STDF
500
19.685
400
0
400
800
15.748
15.748 31.496
Left
Right
Center
Operating point ℓ (mm in)
200
7.874
U-LG
500
19.685
Reflective type Sensing fields
Setting distance L (mm in)
MACHINE
VISION
SYSTEMS
8 mm 0.315 in
approx.
Fiber head
1,000
39.370
U-LG
200
7.874
HUMAN
MACHINE
INTERFACES
FA
COMPONENTS
ℓ
L
1,000
39.37
1,000
39.37
800
31.496
PLC /
TERMINALS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
1,000
39.37
STDF
ℓ
Setting distance L (mm in)
STATIC
CONTROL
DEVICES
H-SP
0
200
7.874
FT-NFM2 FT-NFM2S Thru-beam
FT-NFM2S4 FT-SNFM2 type
Fiber
head
1,500
59.06
STDF
400
15.748
STD
H-SP
200
7.874
0
200
7.874
20
0
20
40
0.787
0.787
1.575
Left
Right
Center
Operating point ℓ (mm in)
ℓ
Fiber
head
L
Fiber
head
100
0
100
200
3.937
3.937
7.874
Left
Right
Center
Operating point ℓ (mm in)
Sensing characteristics are listed by model No. in alphabetical order. (However, models with the same sensing characteristics are listed together.)
FD-FM2
Reflective type
200
7.874
U-LG
400
15.748
STDF
200
7.874
White nonglossy paper
ℓ
L
Fiber
head
STD
STDF
100
3.937
0
20
0.787
50
0
50
100
1.969
1.969
3.937
Left
Right
Center
Operating point ℓ (mm in)
Reflective type
White non-glossy paper
ℓ
U-LG
L
Fiber
head
150
5.906
50
1.969
H-SP
0
100
3.937
50
0
50
100
1.969
1.969
3.937
Left
Right
Center
Operating point ℓ (mm in)
FD-G4
FD-G6X
200
7.874
Setting distance L (mm in)
MEASUREMENT
SENSORS
STD
2,000
78.74
FT-FM2 FT-FM2S FT-FM2S4 Thru-beam
type
FT-SFM2 FT-T80
U-LG
Setting distance L (mm in)
WIRE-SAVING
SYSTEMS
L
Fiber
head
100
0
100
200
3.937
3.937
7.874
Left
Right
Center
Operating point ℓ (mm in)
Setting distance L (mm in)
SIMPLE
WIRE-SAVING
UNITS
ℓ
0
200
7.874
SENSOR
OPTIONS
Fiber
head
H-SP
1,000
39.37
STDF
3,000
118.11
STD
2,000
78.74
Thru-beam type
2,000
78.74
U-LG
Setting distance L (mm in)
INDUCTIVE
PROXIMITY
SENSORS
STDF
Setting distance L (mm in)
PRESSURE /
FLOW
SENSORS
4,000
157.48
U-LG
3,000
118.11
FT-B8
Vertical direction
Setting distance L (mm in)
LIGHT
CURTAINS
Setting distance L (mm in)
AREA
SENSORS
4,000
157.48
The following sensing characteristics pertain to the FX-300 red LED type.Please contact our office for the sensing
characteristics pertaining corresponding to types other than the red LED or to types not mentioned here.
Sensing characteristics are listed by model No. in alphabetical order. (However, models with the same sensing characteristics are listed together.)
Thru-beam type
Setting distance L (mm in)
LASER
SENSORS
FX-300 SERIES
Setting distance L (mm in)
Digital Fiber Sensor
Setting distance L (mm in)
195
White non-glossy paper
ℓ
L
Fiber
U-LG
head
150
5.906
100
3.937
STD
50
1.969
H-SP
STDF
STD
H-SP
40
1.575
10
0
10
20
0.394
0.394
0.787
Left
Right
Center
Operating point ℓ (mm in)
Reflective type
20
0
20
40
0.787
0.787
1.575
Left
Right
Center
Operating point ℓ (mm in)
FX-100
200
7.874
400
15.748
White non-glossy paper
ℓ
U-LG
L
Fiber
head
150
5.906
STDF
100
3.937
50
1.969
STD
H-SP
0
20
0.787
10
0
10
20
0.394
0.394
0.787
Left
Right
Center
Operating point ℓ (mm in)
White non-glossy paper
ℓ
L
U-LG
Fiber
head
300
11.811
200
7.874
STDF
100
3.937
H-SP
0
100
3.937
Reflective type
STD
50
0
50
100
1.969
1.969
3.937
Left
Right
Center
Operating point ℓ (mm in)
FD-W8 FD-WS8
FD-WT8
400
15.748
White non-glossy paper
ℓ
U-LG
L
Fiber
head
300
11.811
200
7.874
100
3.937
0
40
1.575
Reflective
type
STDF
STD
H-SP
20
0
20
40
0.787
0.787
1.575
Left
Right
Center
Operating point ℓ (mm in)
FD-WG4
FD-WSG4
Reflective type
White non-glossy paper
ℓ
L
Fiber
U-LG
head
100
3.937
Setting distance L (mm in)
FD-P81X
Setting distance L (mm in)
FX-311
FX-301-F7/
FX-301-F
FD-NFM2 FD-NFM2S FD-NFM2S4 Reflective
type
FD-SNFM2 FD-T40
Setting distance L (mm in)
FX-410
Setting distance L (mm in)
FX-300
STDF
STD
50
1.969
H-SP
10
0.394
5
0
5
10
0.197
0.197
0.394
Left
Right
Center
Operating point ℓ (mm in)
Digital Fiber Sensor
PRECAUTIONS FOR PROPER USE
Refer to General precautions, p.80~ for fiber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplifier.
•Never use this product as a sensing device
for personnel protection.
•In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
•The digital fiber sensor FX-301(P) has been modified
since its production in June 2004. The explanations
below are about the modified product.
Mounting
35 mm 1.378 in width
DIN rail
②
①
Note: Take care that if the front part is lifted without pushing the
amplifier forward, the hook on the rear portion of the mounting
section is likely to break.
Fiber installation
•Insert the fiber into the amplifier after attaching the
attachment. Refer to the "Instruction Manual" included
with the fiber for details.
ush the fiber lock lever down.
P
Slowly insert the fiber into the insertion
slot until it stops. (Note 1)
Push the fiber lock lever back up until
it stops.
Fiber lock
lever
Fiber
Notes: 1) N
ote that if the fiber is not fully inserted, the sensing distance will
decrease. Also note that the flexible fiber may bend during insertion.
2) In case of coaxial reflective type fibers (FD-G4, FD-FM2, etc.),
mount the central fiber (single-core) to the emitter part and the
peripheral fiber (multi-core) to the receiver. Note that sensing
precision will deteriorate when done in reverse.
Connection
•Make sure that the power supply is off while connecting
or disconnecting the quick-connection cable.
Connection method
Holding the connector of the
quick-connection cable, align
its projection with the groove
at the top portion of the
amplifier connector.
Insert the connector till a click
is felt.
Disconnection method
Pressing the projection at the
top of the quick-connection
cable, pull out the connector.
Groove
Projection
Quick-connection cable
196
FIBER
SENSORS
LASER
SENSORS
Projection
Note: Take care that if the connector
is pulled out without pressing the
projection, the projection may break.
Do not use a quick-connection cable
whose projection has broken.
Further, do not pull by holding the
cable, as this can cause a
cable-break.
Cascading
How to mount the amplifier
F
it the rear part of the mounting section of the
amplifier on a 35 mm 1.378 in width DIN rail.
P
ress down the rear part of the mounting
section of the unit on the 35 mm 1.378 in width
DIN rail and fit the front part of the mounting
section to the 35 mm 1.378 in width DIN rail.
How to remove the amplifier
Push the amplifier forward.
Lift up the front part of the amplifier
to remove it.
FX-300 SERIES
•Make sure that the power supply is off while adding or
removing the amplifiers.
•Make sure to check the allowable ambient temperature,
as it depends on the number of amplifiers connected in
cascade.
•In case two, or more, amplifiers are connected in
cascade, make sure to mount them on a DIN rail.
•When the amplifiers move on the DIN rail depending on
the attaching condition or the amplifiers are mounted
close to each other in cascade, fit them between the
optional end plates (MS-DIN-E) mounted at the two
ends.
•Up to maximum 15 amplifiers can be added (total 16
amplifiers connected in cascade.)
•When connecting more than two amplifiers in cascade,
use the sub cable (CN-71-C□ / CN-72-C□) as the
quick-connection cable for the second amplifier
onwards.
•When connecting amplifiers not close to each other
in parallel, be sure to mount the optional end plate
(MS-DIN-E) at both sides of each amplifier or affix the
communication window seal of the accessory amplifier
protection seal (FX-MB1) to the communication
windows.
•The settings other than the interference prevention
function cannot be transmitted between FX-301(P)
FX-301B/G/H(P), FX-305(P). Therefore, in case both
models of amplifiers are mounted in cascade, be sure
to mount identical models together. However, the
interference prevention function is not incorporated in
the FX-301(P)-HS. Take care when the sensors are
mounted in cascade.
•If the FX-301(P) updated version unit or the FX-305(P)
is mounted with the FX-301(P) previous version unit or
the FX-301B/G/H(P) in cascade, place the FX-301(P)
updated version units and the FX-305(P) units to
the right side (seen from the connector side) of the
previous version units. For details, refer to “Cautions
on sensor connection in cascade”.
For a difference between the updated version unit
and the previous version unit, refer to “A difference
between the updated version unit and the previous
version unit”.
•The communication function of this product and that of
the FX-301(P)-F / F7 is different. If these models are
mounted in cascade, affix the accessory fiber amplifier
protection seal (FX-MB1) included in the FX-301(P)
and FX-305(P) to the communication windows of the
amplifiers.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
197
Digital Fiber Sensor
PRECAUTIONS FOR PROPER USE
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Cascading method
Mount the amplifiers, one by
one, on the 35 mm 1.378 in
width DIN rail.
Slide the amplifiers next to each
other, and connect the quickconnection cables.
Mount the optional end plates
(MS-DIN-E) at both the ends to
hold the amplifiers between
their flat sides.
Tighten the screws to fix the
end plates.
FX-500
FX-100
FX-300
FX-410
Sub cable
(CN-71/72-C□)
(Optional)
<Changing Procedure>
Display [PRO4].
Slide
ong press the [Jog Switch] and
L
[MODE key] at the same time.
(Note 3)
Main cable
(CN-73/74-C□)
(Optional)
End plate
(MS-DIN-E)
(Optional)
Group B's Communication
Specification
Group A's Communication
Specification
<Figure A> <Figure B>
Optical communications Optical communications
are possible
are impossible
Group A
Group B
Group B
Group A
Group A
FX-301(P): Previous version unit
(Note 1), FX-301G(P)/B(P)/H(P),
FX-41□(P), LS-401(P) (Note 2)
Group B
FX-301(P): Updated version
unit (Note 1), FX-305(P)
Notes: 1) For the difference between the updated
version unit and the previous version
unit, refer to “A difference between the
updated version unit and the previous
version unit”.
2) W
hen LS-401(P) is connected with the
digital fiber amplifier in cascade, be sure to
locate LS-401(P) at the left-most position
(when viewed from the connector side).
•When the units of the group A and the group B are
connected in cascade as <Figure B> shown above,
optical communications cannot be done. When the
optical communications function is used, connect them as
<Figure A> shown above. If the units cannot be placed
as <Figure A>, the following measure 1 or 2 should be
taken.
1
2
Optical Communication Stop
Notes: 3) E
very time the [Jog Switch] and the [MODE key] is
simultaneously long pressed, the display changes in
this sequence: “ ”→“ ”→“ ”→“ ”→“ ”.
•When the units in the group A and the group B shown in
the table below are connected in cascade, connect them
in cascade as <Figure A> shown below.
FX-311
FX-301-F7/
FX-301-F
Sub unit
Cautions on sensor connection in cascade
UV
CURING
SYSTEMS
Amplifiers
Main unit
How to change the communication specification of Group B
•Change the communication specification of Group B
according to the following procedures. Make sure to set the
communication specification to “ (Group A communication
specification)” or “ (Optical Communication Stop)”.
W
hen you release the [Jog Switch] and
[MODE key], the communication specification
will be set and “PRO4” will be displayed.
Slide
MACHINE
VISION
SYSTEMS
Fibers
Refer to General precautions, p.80~ for fiber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplifier.
35 mm 1.378 in
width DIN rail
Dismantling
Loosen the screws of the end
plates.
Remove the end plates.
Slide the amplifiers and remove
them one by one.
FA
COMPONENTS
Selection
Guide
FX-300 SERIES
ffix the communication window seal of the accessory
A
fiber amplifier protection seal (FX-MB1) to the
communication window of the FX-301(P) updated
version unit or FX-305(P).
If the measure 1 described above cannot be taken,
change the optical communications spec. of the group B
units.
Notes: 4) When the communication specification is set to “ (Group A
communication specification)”, make sure to tightly attach the
products. Also make sure to take note of the following:
• There are instances when the optical communication function
cannot be used due to the usage environment, etc.
• Do not perform batch channel loading or saving.
Part description
MODE indicator / L/D ON (Yellow)
MODE indicator / TIMER (Yellow)
Stability indicator
(Green)(Note2)
Operation indicator (Orange) (Note1)
MODE indicator / RUN (Green)
MODE indicator /
PRO (Yellow)
MODE indicator / TEACH (Yellow)
MODE indicator / ADJ (Yellow)
MODE key
Jog switch
Digital display (Red)
Notes: 1) FX-305(P); Output 1 operation indicator (Orange)
2) FX-305(P); Output 2 operation indicator (Orange)
Operation procedure
•When the power supply is switched on, communication
self-check is carried out and normal condition is
displayed [MODE indicator / RUN (green)] lights up and
the digital display shows the incident light intensity.
•When the MODE key is pressed, the mode will change as
shown in the following diagram.
Power ON
Communication self-check
RUN
Press
MODE key
Press
MODE key
[Teaching]
TEACH
(P.198)
Press
MODE key
[Threshold
value fine
adjust] (P.199)
ADJ
PRO
Press
MODE key
[PRO mode]
(P.202)
TIMER [Timer operation
setting] (P.199)
Press
MODE key
Press
MODE key
L/D
[Output operation
setting] (P.199)
When Jog switch is pressed, the setting is confirmed.
When MODE key is pressed for 2 sec., or more, the sensor returns to the ‘RUN’ mode.
Cancellation is possible by pressing MODE key during setting.
Digital Fiber Sensor
PRECAUTIONS FOR PROPER USE
Refer to General precautions, p.80~ for fiber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplifier.
For FX-305(P)
In case of full auto-teaching
The FX-305(P) is equipped with two independent outputs, but
the items that can be set in output 1 and output 2 respectively
are only the following.
The items other than those are common.
1 Threshold value 2 Output operation
3 Timer operation and Timer period 4 Sensing mode
Teaching
•The threshold values can be set by 2-point teaching, limit
teaching, full-auto teaching or window comparator mode
(1-point, 2-point, 3-point teaching) [only for FX-305(P)],
when the MODE indicator / TEACH (yellow) lights up.
In case of 2-point teaching
•This is the method of setting the threshold value by teaching
two levels, corresponding to the object present and object
absent conditions. Normally, setting is done by this method.
Step
Description
Display
Set the fiber within the
sensing range.
Press MODE key to light
up MODE indicator /
TEACH (yellow).
For FX-305(P), select either Output 1 “
” or
Output 2 “
” beforehand, press jog switch
in the object present condition.
If the teaching is accepted, the read incident
light intensity blinks in the digital display.
Thru-beam type
Reflective type
Mark
Beam
blocked condition
Background
MODE indicator / TEACH (yellow) blinks.
Press jog switch in the object absent condition.
Thru-beam type Reflective type
Mark
Beam
incident condition
FX-300 SERIES
Background
If the teaching is accepted, the read incident
light intensity blinks in the digital display
and the threshold value is set at the midvalue between the incident light intensities
in the object present and the object absent
conditions. After this, the judgment on the
stability of sensing is displayed.
• In case stable sensing is possible: “
” is displayed.
• In case stable sensing is not possible: “
” blinks.
The threshold value is displayed.
“
” blinks in the digital display.
(only FX-301B/G/H)
The incident light intensity appears in the
digital display and the setting is complete.
Notes: 1) Do not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
2) In case a reflective-type fiber is used, maximum sensitivity will be
set if the jog switch is pushed while in no work status in procedure
and .
•Full auto-teaching is used when it is desired to set the
threshold value without stopping the assembly line, with
the object in the moving condition.
Step
Description
Display
Set the fiber within the
sensing range.
Press MODE key to light
up MODE indicator /
TEACH (yellow).
For FX-305(P), select either Output 1 “
” or
Output 2 “
” beforehand, press the jog switch
continuously for 0.5 sec. or more with the object
moving on the assembly line. (The incident light
intensity is displayed during sampling.)
“
” is displayed on the digital display. Release
the jog switch when the object has passed.
198
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
If the teaching is accepted, the read incident
light intensity blinks in the digital display
and the threshold value is set at the midvalue between the incident light intensities
in the object present and the object absent
conditions. After this, the judgment on the
stability of sensing is displayed.
• In case stable sensing is possible: “
” is displayed.
• In case stable sensing is not possible: “
” blinks.
SIMPLE
WIRE-SAVING
UNITS
The threshold value is displayed.
ENDOSCOPE
“
” blinks in the digital display.
(only FX-301B/G/H)
The incident light intensity appears in the
digital display and the setting is complete.
Notes: 1) The threshold value’s shift amount can be selected in PRO mode.
Refer to the “PRO Mode Operation Guide” for more details
pertaining to setting instructions. (Increments of 5 % between –45
and 45 % for setting possible. 0 % default.)
2) D
o not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
199
FIBER
SENSORS
LASER
SENSORS
Digital Fiber Sensor
FX-300 SERIES
PRECAUTIONS FOR PROPER USE
Refer to General precautions, p.80~ for fiber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplifier.
MICRO
PHOTOELECTRIC
SENSORS
In case of limit teaching
•This is the method of setting the threshold value by
teaching only the object absent condition (stable incident
light condition). This is used for detection in the presence
of a background body or for detection of small objects.
AREA
SENSORS
Step
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Description
Thru-beam type Reflective type
Background
body
Beam
incident condition
STATIC
CONTROL
DEVICES
If jog switch is turned to the “+” side, “
” scrolls
(twice) the display from right to left (Note 1), and the
threshold level is shifted to a value
+
approx. 15 % higher (lower sensitivity)
than that set at . (Note 2)
This is used in case of reflective type fibers.
If jog switch is turned to the “–” side, “
” scrolls
(twice) the display from left to right, and the threshold
level is shifted to a value approx.
15 % lower (higher sensitivity)
than that set at . (Note 2)
This is used in case of thru-beam type fibers.
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
High
OFF
Threshold
value
PLC /
TERMINALS
100 %
Low
0
ON
15 %
Threshold value
Incident light intensity
with object absent
15 %
ON
OFF
Threshold value
Turn to “+” side
Turn to “–” side
After this, the judgment on whether the setting
shift amount can be shifted or not is displayed.
• I n case shifting is possible: “
” blinks.
• I n case shifting is not possible: “
” blinks.
Fibers
Amplifiers
The threshold value is displayed.
FX-500
“
” blinks in the digital display.
(only FX-301B/G/H)
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
Display
–
For FX-305(P), select either Output 1 “
”
or Output 2 “
” beforehand, in case the
threshold value is to be increased (sensitivity
to be reduced), turn the jog switch +
to the “+” side to increase the
threshold value slowly. If the
jog switch is turned continuously to the “+”
side, the threshold value increases rapidly.
In case the threshold value is to be decreased
(sensitivity to be increased), turn the jog
switch to the “–” side to decrease the
threshold value slowly. If the jog
−
switch is turned continuously to
the “–” side, the threshold value
decreases rapidly.
When jog switch is pressed,
the threshold value is
confirmed.
For FX-305(P), select either Output 1 “
” or
Output 2 “
” beforehand, press jog switch
in the object absent condition. If the teaching
is accepted, the read incident light intensity
blinks in the display.
MODE indicator / TEACH (yellow) blinks.
Turn jog switch to the “+” side or “–” side.
LASER
MARKERS
Description
Press MODE key to light
up MODE indicator / ADJ
(yellow).
Display
MEASUREMENT
SENSORS
ENDOSCOPE
Step
Set the fiber within the
sensing range.
Press MODE key to light
up MODE indicator /
TEACH (yellow).
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Threshold value fine adjustment
The incident light intensity appears in the
digital display and the setting is complete.
Notes: 1) Scrolling display is not available in FX-301B/G/H.
2) The approx. 15 % amount of shift is the initial value. The amount of
shift can be changed in the PRO mode from approx. 5 to 80 %
(5 % step). Refer to the “PRO Mode Operation Guide” for more
details pertaining to setting instructions.
3) Do not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
Please download the instruction manual from our website for
setting of threshold value when used in combination with liquid
level sensing fiber FD-F8Y and with pipe-mountable liquid level
sensing fiber FD-F4□.
For the wind comparator mode teaching in FX-305(P), refer to
the separately prepared “PRO Mode Operation Guide”.
or
–
Output operation setting
Step
Description
Press MODE key to light
up MODE indicator / L/D
ON (yellow).
For FX-305(P), select either Output 1 “
or Output 2 “
” beforehand,
if the jog switch is turn to
−
the “+” or “–” direction,
+
the output operation setting
will change.
When jog switch is pressed,
the threshold value is
confirmed.
Display
Displays
present setting
”
Light state
Dark state
Displays
selected setting
Timer operation setting
•The setting for whether the timer is used or not can be
done when MODE indicator / TIMER (yellow) lights up.
For FX-301B/G/H, the timer type can be set in PRO
mode.
•Further, an OFF-delay (initial value) which is useful when
the response of the connected device is slow, etc., an
ON-delay which is useful to detect only objects taking a
long time to travel, and ONE SHOT, which is useful when
the input specifications of the connected device require a
signal of a fixed width, are possible with the FX-301□(-HS).
FX-305(P) is also equipped with ON-delay • OFF-delay and
ON-delay • ONE SHOT timers. Refer to the “PRO Mode
Operation Guide” for the setting method of the OFF-delay,
ON-delay and ONE SHOT timer intervals.
Digital Fiber Sensor
PRECAUTIONS FOR PROPER USE
FX-300 SERIES
Refer to General precautions, p.80~ for fiber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplifier.
Wiring
FIBER
SENSORS
LASER
SENSORS
Key-lock function
•Make sure that the power supply is off while wiring.
•Verify that the supply voltage variation is within the rating.
•Take care that if a voltage exceeding the rated range is
applied, or if an AC power supply is directly connected,
the product may get burnt or damaged.
•If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
•In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this
product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
•Take care that short circuit of the load wrong wiring may
burn or damage the product.
•Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
•Make sure to use an isolation transformer for the DC
power supply. If an autotransformer (single winding
transformer) is used, this product or the power supply
may get damaged.
•Make sure to use the optional quick-connection cable for
the connection of the amplifier. Extension up to total 100
m 328.084 ft is possible with 0.3 mm2, or more, cable.
(5-8 unit expansion: 50 m 164.042 ft, 9-16 unit
expansion: 20 m 65.617 ft) However, in order to reduce
noise, make the wiring as short as possible.
•Note that the residual voltage will increase when the
cable is extended.
200
•If jog switch and MODE key are pressed for more than
2 sec. at the same time in ‘RUN’ mode condition, the
key operations are locked, and only the threshold value
confirmation function or the adjust function (valid only
when the adjust lock function is canceled) is valid.
To cancel the lock function, press both the keys for more
than 2 sec. once again.
Note: 3 seconds or more for FX-301B/G/H(P).
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
Others
•When the emission halt of the light emitting amount
selection function is set from “OFF” to “ON”, the output
may be unstable. Do not use the output control for 0.5
sec. after starting emission.
•Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
•Take care that the sensor is not directly exposed to
fluorescent lamp from a rapid-starter lamp, a high
frequency lighting device or sunlight etc. , as it may affect
the sensing performance.
•Do not use this sensor in places having excessive vapor,
dust, etc., or where it may come in contact with corrosive
gas.
•Take care that the product does not come in direct
contact with water, oil, grease, or organic solvents, such
as, thinner, etc.
•This sensor cannot be used in an environment containing
inflammable or explosive gases.
•Never disassemble or modify the sensor.
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
Function table for FX-300 series
MACHINE
VISION
SYSTEMS
Previous models
Standard type
FX-301(P)
(Previous version unit)
New models
High-function type High-speed type
FX-302(P)
Standard type
High-speed type High-function type
FX-303(P)
FX-301(P)
(Updated version unit)
FX-301(P)-HS
FX-305(P)
Four-chemical emitting element + APC circuit
No
No
No
Yes
Yes
Yes
Four-chemical emitting element only
Yes (Note)
Yes
Yes
–
–
–
Light emitting amount selection function
No
No
No
Yes
Yes
Yes
Reduced intensity mode (S-D)
Yes (Note)
Yes
No
Yes
Yes
–
9,999 digit display
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
No
No
No
No
No
Yes
Response time (Max. speed)
150 μs
300 μs
90 μs
65 μs
35 μs
65 μs
FX-500
Interference prevention function (Effective no. of units)
Incorporated (4)
Incorporated (8)
Not incorporated (0)
Incorporated (4)
Not incorporated (0)
Incorporated (16)
FX-100
Independent 2 outputs
No
No
No
No
No
Yes
Alarm output function
No
No
No
No
No
Yes
FX-300
Error output function
No
No
No
No
No
Yes
Differential sensing
No
No
No
No
No
Yes
Window comparator mode
No
Yes
No
No
No
Yes
Peripheral units that can be combined
Bank selection unit
FX-CH(-P)
Yes
Yes
No
No
No
No
External input unit
FX-CH2(-P)
No
No
No
Yes
No
Yes
Upper communication unit
SC-GU1-485
No
No
No
Yes
No
Yes
Note: Except FX-301B/G/H.
FX-410
FX-311
FX-301-F7/
FX-301-F
201
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Digital Fiber Sensor
FX-300 SERIES
PRECAUTIONS FOR PROPER USE
Refer to General precautions, p.80~ for fiber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplifier.
A difference between the updated version unit and
the previous version unit for FX-301(P) (Red LED type)
•The product has been modified as shown below since its
production in June 2004.
Changes in appearance
Before change
Top view
After change
Top view
Name
plate
Display
Uses special parts
Side view
Display changes
Change in shape
of jog switch
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
* “NAVI” is printed only on the both sides
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
* “NAVI” is printed only on a side
1. Checking blinking of sensitivity surplus
The stable surplus display method after teaching has been changed.
Previous version unit: Sensitivity surplus is indicated by the number
of blinks of the stability indicator.
After change
Digital display only
•Checking minor changes between previous and
updated models can be done by checking whether the
printing is on both sides or only one side.
1. Response times added
An ultra high-speed mode (H-SP) has been added to
the existing 4 response time modes [high-speed (FAST),
reduced intensity (S-D), standard (STD) and long range
(LONG)].
This is changed using “
” in “
”
Before change
4 steps
2. Initial direct code value changed
The factory default settings for the direct codes have been changed.
Previous version unit 0000
Upgraded functions
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
1. Timer selection method
Previous version unit: Timer type was changed using PRO1 mode.
The “TIMER” setting in NAVI mode could
only be turned on or off.
After change: T
he type of timer can be changed using the “TIMER”
function in NAVI mode.
2. Checking threshold value in RUN mode
The threshold values can be checked by turning the jog switch.
Added to
name plate
Side view
Changes in operation
After change
After change 0004
*T
he default setting for the timer period is 10 ms, and the direct code for
10 ms is “4”, so this has been changed.
Internal circuit changes
1. Addition of an APC circuit
A four-chemical emitting element which provides stable
sensing over• long• periods• has been added, as well
as an APC (Auto Power Control) circuit that improves
stability during short periods.
Cautions on sensor connection in cascade
5 steps
150 μs (FAST)
65 μs (added) (H-SP)
250 μs (S-D)
150 μs (FAST)
250 μs (STD)
250 μs (S-D)
2 ms (LONG)
250 μs (STD)
2 ms (LONG)
2. Extension of timer period
The setting range for the timer period was previously
500 ms, but this has been extended to a new range of
9,999 ms.
3. Light emitting amount selection function
The light emitting amount can be changed to one of
4 levels (5 levels when emission halt is included).
4. Backup, copy lock and key lock functions added
Backup: This selects whether or not threshold values
set by teaching are written to (stored in) an
EEPROM.
Copy lock: This selects whether copy function and data
bank function communication are possible or
not.
Key lock: This disables input using switches to prevent
accidental changing of settings.
When connecting the previous version unit (including
FX-301B/G/H) and updated version unit to be used in a
cascade, refer to “Cautions on sensor connection in
cascade”.
Digital Fiber Sensor
PRECAUTIONS FOR PROPER USE
FX-300 SERIES
Refer to General precautions, p.80~ for fiber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplifier.
202
FIBER
SENSORS
Diagram of functions and settings
LASER
SENSORS
The amplifier features and settings are generally classified into two main modes; the “NAVI mode” for items and settings that
are frequently reconfigured, and the “PRO mode” that contains more detailed settings.
PHOTOELECTRIC
SENSORS
RUN
TEACH
Run
This indicates normal sensing operation.
NAVI
mode
PRO
Teaching
The “threshold value” can be set by
utilizing either “2-point teaching”, “limit
teaching”, or “full-auto teaching”.
* When the FX-305(P) is in window comparator mode,
the “threshold value” can be set by either “1-point
teaching”, “2-point teaching” or “3-point teaching”.
TIMER
Pro
Allows various detailed settings to be
configured, such as optical communications,
save / load and other settings.
ADJ
Allows fine adjustment of the
“threshold value”.
Configures operation of the timer.
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
L/D
Timer
Adjust
MICRO
PHOTOELECTRIC
SENSORS
L-ON / D-ON
Sets output operation either Light-ON,
or Dark-ON.
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Response Time Change
PRO1
Switches among response times.
Configures timer operation.
Light Emitting Amount Selection
Changes the light emitting amount
selection setting.
[FX-301(P)(-HS), FX-305(P) only]
Allows selection of different content
to be indicated in the digital display.
Sets hysteresis level.
Shift
Shifts the “threshold value” by a
certain percentage increment in
“limit teaching”.
Digital Display Setting
PRO2
Hysteresis
Timer Setting
Stability
Permits selection of stability indicator response
levels for changes in the range for lighting up.
[excluding the FX-305(P)]
Digital Display Inversion
Sets the viewing orientation of the
digital display.
ECO Mode
Sets the digital display to turn
ON / OFF.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
PRO3
PRO
mode
Data Bank Load
Data Bank Save
HUMAN
MACHINE
INTERFACES
Loads configuration setting from the
data bank.
Saves configuration setting into the
data bank.
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
Copy
PRO4
* The FX-301(P)-HS is not
equipped with a PRO4
setting function.
Using optical communications, configuration
settings from the main unit are copied to
connected sub units all at once.
Backup
Allows not to save the threshold value, by
teaching via external input in EEPROM.
[FX-301(P), FX-305(P) only]
Remote Data Bank Load
Remote Data Bank Save
Using optical communication, configuration
settings can be loaded from respective data
banks all at once.
Using optical communication, current
configuration settings can be saved into
respective data banks all at once.
Communication Change
To Permit / Not to Permit
When using optical communication for carrying out
copy / load / save operations all at once, this function
allows optical communication to pass through the unit.
Verifies whether optical communications
have been properly established.
(FX-301B/G/H only)
Code
PRO5
Available only in FX-305(P)
Allows fine adjustment of the “threshold
value” to be directly performed during
RUN mode.
Normal Mode
PRO6
Sets a threshold value for ON /
OFF operation.
Reset
All settings, except for data bank
information, revert to factory settings.
Interference Prevention
Switching
Switches the number of units for which
interference prevention switching is enabled.
* FX-305(P) only.
The items that can be set are different for output 1 and output 2.
Rising Differential Mode
Window Comparator Mode
Output 1 Judges if set two threshold values are within the
required range or not. This can be selected in
1-point / 2-point / 3-point teaching.
Sensing mode that cancels out slight changes in
light intensity so that only sudden increases in
incident light intensity are sensed.
Output 2
Error Output
Alarm Output
Trailing Differential Mode
Output when overcurrent occurs or when
a communication error occurs from
connected incompletely.
Be used as alarm output when the threshold
value for output 2 is linked to output 1 and
the light amount drops.
Sensing mode that cancels out slight changes in
light intensity so that only sudden decreases in
incident light intensity are sensed.
UV
CURING
SYSTEMS
Test
Adjust Lock
Allows basic configuration information
to be set in a single step, by inputting
a 4-digit code.
MACHINE
VISION
SYSTEMS
* The 0-ADJ setting function equipped on the FX-301□ and FX-305(P) has been deleted since the production in May 2005.
Selection
Guide
Fibers
Amplifiers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
203
FIBER
SENSORS
LASER
SENSORS
Digital Fiber Sensor
DIMENSIONS (Unit: mm in)
AREA
SENSORS
LIGHT
CURTAINS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
STATIC
CONTROL
DEVICES
MODE key
Jog switch
3
0.118
10
0.394
64.5
2.539
Communication
window
Beamemitting
part
7 0.276
Beamreceiving
part
10.5
0.413
7 0.276
3
0.118
13.5
0.531
•Length L
UV
CURING
SYSTEMS
Selection
Guide
3.95
0.156
Suitable for 35 mm
1.378 in width DIN rail
36.5
1.437
Main cable (Optional)
Length L
CN-73/74-C1
1,000 39.370
CN-73/74-C2
2,000 78.740
CN-73/74-C5
5,000 196.850
2.65
0.104
(Note 2)
50
1.969
ø3 ø0.118 cable
14
(0.551
)
2.54
0.100
(Note 1)
CN-71-C□ CN-72-C□
Sub cable (Optional)
•Length L
L
Model No.
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
(Note 3)
Notes: 1) FX-305□; Output 1 operation indicator (Orange)
2) FX-305□; Output 2 operation indicator (Orange)
3) FX-301□; 3-pin, FX-305□; 4-pin
LASER
MARKERS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
3.3
0.130
7
0.276
27.8
1.094
30.5
1.201
CN-73-C□ CN-74-C□
HUMAN
MACHINE
INTERFACES
0.7
0.028
Digital display (Red)
ENDOSCOPE
PLC /
TERMINALS
12
0.472
Stability indicator
(Green) (Note 2)
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Amplifier
48.2
26.3 1.898
1.0352.5
0.098
8.3
Operation indicator
(Orange) (Note 1) 0.327
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
The CAD data in the dimensions can be downloaded from our website.
FX-301□ FX-305(P)
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
FX-300 SERIES
2.9
(0.114
)
10
0.394
6
0.236
2.54
0.100
CN-71/72-C1
1,000 39.370
CN-71/72-C2
2,000 78.740
CN-71/72-C5
5,000 196.850
7
0.276
10
0.394
13.6
0.535
3
0.118
(Note 2)
14
(0.551
)
3
0.118
2.9
(0.114
)
10
0.394
6
0.236
( )
12 10.5
(0.472
) 0.413
2.54
0.100
2.65
0.104
7.2
0.283
50
1.969
ø3 ø0.118 cable
2.54
0.100
(Note 1)
0.2
0.008
Notes: 1) CN-74-C□ only
2) CN-73-C□; 3-core
Length L
( )
12 10.5
(0.472
) 0.413
L
Model No.
0.2
0.008
Notes: 1) CN-72-C□ only
2) CN-71-C□: 1-core
7
0.276
10
0.394
13.6
0.535
3
0.118
7.2
0.283
Fibers
Amplifiers
FX-500
FX-100
MS-DIN-2
Amplifier mounting bracket (Optional)
10
0.394
3.2
0.126
FX-410
FX-311
End plate (Optional)
2.75
0.108
3.2
0.126
8.5
0.335
FX-300
FX-301-F7/
FX-301-F
21.6 0.850
16 0.630
5.2
0.205
MS-DIN-E
0.4
0.016 ø1.8
ø0.071
7.5
0.295 4.2 0.165
5.2
0.205
35
1.378
2
0.079
2
0.079
2-ø3.2 ø0.126 holes
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
5
0.197
15
0.591
60
2.362
3
0.118
5.6 M3 square nut
0.220
24.7
0.972
t1
t 0.039
27
1.063
M3 (length 18 mm 0.709 in) pan head screws
3
0.118
1.6
0.063
32
1.260
Material: Polycarbonate
4
0.157
Suitable for 35 mm 1.378 in width DIN rail
204
MEMO