PROGRAMMING LIST
Alarm Control Panel
CA10 plus
(Program Version 4.7)
®
GDAŃSK
ca10plis_e 07/03
History of the Manual Updates.
The updates below refer to the manual for the control panel with program version 4.1.
Date
01-2003
07-2003
Program
Description of updates
version
y
A new type of zone reaction added in the FS-26 function:
4.3
„19 - perimeter”.
y
New formats of transmission to the monitoring station added in the
functions FS-45, FS-46:
ƒ 0E - Contact ID selected codes
ƒ 0F - Contact ID all codes
y
Event no. 6 (disarming & clearing alarm) removed from the functions
FS-69 to FS-80 – the code is recommended not to be programmed or
assigned to the stations .
y
A second set of options added in the FS-131 function (1-4).
y
A new function added: FS-133.
y
A new type of zone reaction added in the FS-26 function:
4.7
„20 – enter/exit-final ”.
y
New format of transmission to the monitoring station added in the
functions FS-45, FS-46 „TELIM”.
y
On page 11 in the table new zone event codes added (FS 134-135). In
FS 67-68 functions bit 8 is used for assignment new events to
monitoring stations.
y
New functions added: FS-125, FS-134-137.
y
In second set of option in the FS-131 function added 3 new options (57).
CA-10 plus SATEL - Programming List
1
ALARM SYSTEM
.......................................................................
ADDRESS
.................................................................................
USER
.......................................................................
REMARKS .................................................................................
TELEPHONE NUMBER .......................................................................
.................................................................................
|__|__|__|__|__|__|#
default = |1|2|3|4|5|_|
|__|__|#|__|__|#|__|__|#
|2|1||4|3||6|5|
|__|__|#|__|__|#|__|__|#
|6|5||8|7||0|9|
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 1 - SERVICE CODE
FS 2 - CONTROL PANEL ID
FS 3 - COMPUTER ID
FS 4 - COMPUTER TEL. NO.
default: |A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#
maximum of 16 characters 0–F, A=end of the number, B=pulse dial, C=tone dial, D=wait for the continuous tone , E=short pause, F=long pause
FS 5 - SYSTEM OPTIONS
(by default all options off)
First options set (LED 12 blinking)
Second options set (LED 11 blinking)
Third options set (LEDs 11 & 12 blinking)
1
TELEPHONE MESSAGING
1
DOWNLOADING FROM OUTSIDE
ALLOWED
1
DISABLE SERVICE MODE WHEN ANY
PARTITION ARMED
2
MONITORING
2
TONE DIALING
2
3
CALL ANSWERING
3
DOUBLE MESSAGE FROM SYNTHESIZER
3
4
PRINTING
4
GROUND START
4
5
PRINTER CR + LF MODE
5
NO DIAL TONE TEST
5
6
PRINTER RS-232 2400Bps (OFF-1200Bps)
6
NO ANSWER TEST
6
DISABLE DOWNLOADING WHEN
ARMED
ALARM IF ANY ZONE IS VIOLATED
WHEN EXIT TIME IS OVER
FIRE ALARMS INDIVIDUAL IN EACH
PARTITION
KEYPAD ALARMS INDIVIDUAL IN
EACH PARTITION
SUSPEND MONITORING UNTIL NEW
EVENT (OFF FOR 30 MIN.)
7
OUT 5,6 TRANSMISSION TYPE: UA
8
OUT 5,6 TRANSMISSION TYPE:LV&BY**
7
TRANSMISSION WITH PARITY
7
SERIAL TRANSMISSION ON OUTPUT 5, 6 *
(FOR NOKTON RADIO MESSAGING)
8
PARITY: ON-EVEN / OFF-ODD
8
DOUBLE CALL TO ANSWER
Confirm by pressing #.
Confirm by pressing #.
Confirm by pressing #.
* Monitoring is suspended in case of problems in communication with the monitoring station (after 16 failed connection attempts).
** Options 7 and 8 in third set are only relevant if option 7 in second set is on. When UA & LV&BY transmission is disabled (LEDs 7 & 8 are off), outputs 5 and 6 work in NOKTON
(PC16OUT) format.
FS 6 - GLOBAL SYSTEM TIMES
(program: 00 do 99 sec.)
|__|__|#
entry delay
|__|__|#
default exit delay
|__|__|#
default alarm time
default: |3|0|#|6|0|#|6|0|# sec.
*
**
CA-10 plus SATEL - Programming List
2
|__|__|# |__|__|# |__|__|#
FS 7 - COUNTING ZONES COUNTERS
(program: 00 to 07)
Counter
1
2
|0|0|#|0|0|#|0|0|#
3
FS 8÷11 and 12÷15 PARTITION ZONES, ZONES DISPLAYED IN LED KEYPADS
Zones to partitions assignment
Zones to LED keypads assignment
FS 8
Part. 1
FS 9
Part. 2
FS 10
Part. 3
FS 11
Part. 4
FS 12
Kpd. 1
FS 13
Kpd. 2
FS 14
Kpd. 3
FS 15
Kpd. 4
ZONE 1
1
1
1
1
1
1
1
1
ZONE 2
2
2
2
2
2
2
2
2
ZONE 3
3
3
3
3
3
3
3
3
ZONE 4
4
4
4
4
4
4
4
4
ZONE 5
5
5
5
5
5
5
5
5
ZONE 6
6
6
6
6
6
6
6
6
ZONE 7
7
7
7
7
7
7
7
7
ZONE 8
8
8
8
8
8
8
8
8
1
1
1
1
1
1
1
2
2
2
2
2
2
2
Confirm by pressing #
ZONE 9
1
ZONE 10
2
ZONE 11
3
3
3
3
3
3
3
3
ZONE 12
4
4
4
4
4
4
4
4
ZONE 13
5
5
5
5
5
5
5
5
ZONE 14
6
6
6
6
6
6
6
6
ZONE 15
7
7
7
7
7
7
7
7
ZONE 16
8
8
8
8
8
8
8
8
Confirm by pressing #
-default settings
CA-10 plus SATEL - Programming List
3
FS 16÷19 & 127÷130 AUTO-BYPASSED ZONES.
Auto-bypassed zones
(silent or partial arming)
Auto-bypassed zones
(no exit from the facility)
FS 16
Part. 1
FS 17
Part. 2
FS 18
Part. 3
FS 19
Part. 4
FS 127
Part. 1
FS 128
Part. 2
FS 129
Part. 3
FS 130
Part. 4
ZONE 1
1
1
1
1
1
1
1
1
ZONE 2
2
2
2
2
2
2
2
2
ZONE 3
3
3
3
3
3
3
3
3
ZONE 4
4
4
4
4
4
4
4
4
ZONE 5
5
5
5
5
5
5
5
5
ZONE 6
6
6
6
6
6
6
6
6
ZONE 7
7
7
7
7
7
7
7
7
ZONE 8
8
8
8
8
8
8
8
8
ZONE 9
1
1
1
1
1
1
1
1
ZONE 10
2
2
2
2
2
2
2
2
ZONE 11
3
3
3
3
3
3
3
3
ZONE 12
4
4
4
4
4
4
4
4
ZONE 13
5
5
5
5
5
5
5
5
ZONE 14
6
6
6
6
6
6
6
6
ZONE 15
7
7
7
7
7
7
7
7
ZONE 16
8
8
8
8
8
8
8
8
”
Confirm by pressing #
Confirm by pressing #
CA-10 plus SATEL - Programming List
4
FS 20÷23 - PARTITION OPTIONS
GO TO function disabled
FS 20
Partition 1
1 GOTO 2
GO TO function disabled
2
GOTO 3
2
GOTO 3
2
GOTO 2
2
GOTO 2
GO TO function disabled
3
GOTO 4
3
GOTO 4
3
GOTO 4
3
GOTO 3
QUICK ARM function disabled
4
4
4
4
3 wrong codes alarm disabled
5
5
5
5
PANIC keypad alarm disabled
6
6
6
6
AUX. keypad alarm disabled
7
7
7
7
FIRE keypad alarm disabled
8
8
8
8
Keypad alarm on until cleared with a code
1
1
1
1
Keypad alarm on for the set alarm time
2
DAY/NIGHT zone violation signal
3
CHIME zone violation signal
4
4
4
4
Failure audible signal
5
5
5
5
Keypad EXIT DELAY signal
6
Keypad ENTRY DELAY signal
7
Key pressed signal
8
To turn on an option set the corresponding control on.
FS 21
Partition 2
1 GOTO 1
FS 22
Partition 3
1 GOTO 1
FS 23
Partition 4
1 GOTO 1
Confirm by pressing #
Confirm by pressing #
2
3
6
7
8
2
3
6
7
8
2
3
6
7
8
-default settings
CA-10 plus SATEL - Programming List
5
FS 24 - ZONE SENSITIVITY
ZONE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
Value
Default
Note: Controls 1–8 will not display the new parameter value.
Program values 1 to 255. Confirm each number by pressing #.
Default value for all zones 30 (30*16 ms = 0,480 sec.).
FS 25 - ZONE CONNECTION (program: 00 - 05)
00
01
02
Zone
no detector
NC detector
NO detector
1
03
04
05
2
3
4
5
EOL detector
2EOL/NC detector
2EOL/NO detector
6
7
8
9
10
11
12
13
14
15
16
Type
Default
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
0
0
0
0
0
0
0
0
0
0
0
Note: The FS107 restart function sets 03 for existing zones and 00 for not existing ones; the default values are given for the system with one keypad connected to CLK1.
FS 26 - ZONE REACTION TYPE (program: 00 - 20)
00 - exit/entry
01 - delay
02 - interior delay
03 - instant
04 - day/night
05 - instant counting L.1
06 - instant counting L.2
07 - instant counting L.3
08 - 24H audible
09 - 24H auxiliary
10 - 24H silent
Zone
1
11 - 24H fire
12 - arming
13 - silent arming
14 - disarming
15 - no alarm action
16 - arming/disarming
17 - delay with entry delay warning
18 - automatic bypass arming
19 – perimeter
20 – exit/entry-final
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Value
Default
0
0
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
CA-10 plus SATEL - Programming List
6
FS 27 - PROGRAMMING ZONE OPTIONS
zone number displayed on LEDs 9 ÷ 12
Zones:
Option
1
2
3
4
5
6
PRIORITY
(must not be violated on arming)
CHIME
(violation generates CHIME signal)
AUTO-RESET 1
(auto-bypassed after first alarm)
AUTO-RESET 3
(auto-bypassed after third alarm)
ABORT DELAY (no violation
reporting during ENTRY DELAY)
POWER UP DELAY
(bypass for 120s after power on)
7
report RESTORE after alarm ends
8
report RESTORE after DISARM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Options are programmed by lighting the corresponding controls (activating options) in turn for 16 zones. Confirm the option for each zone by pressing #.
- Options enabled by default; the other options are disabled.
FS 28 - INDIVIDUAL ZONE ENTRY DELAY
ZONE:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Entry
Delay
Note: program 00 to 99 seconds, confirm by pressing #.
By default, the individual entry delay times are set at 0.
FS 29 - MAXIMUM ZONE VIOLATION TIME
ZONE
1
2
3
4
5
6
7
8
9
10
11
12
Value
Note: Controls 1–8 will not display the new parameter value. Program values from 0 to 255 sec.. Confirm each number by pressing #.
By default, the maximum violation times are set at 0 for all zones (violation time control off).
13
14
15
16
CA-10 plus SATEL - Programming List
7
FS 30 - MAXIMUM ZONE NO VIOLATION TIME
ZONE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Value
Note: Controls 1–8 will not display the new parameter value. Program values from 0 to 255 sec.. Confirm each number by pressing #.
By default, the maximum violation times are set at 0 for all zones (no violation time control off).
FS 31 ÷ 42 - OUTPUTS PROGRAMMING
OUTPUT TYPES:
00 not used
01 BURGLARY signaling
02 BURGLARY/FIRE signaling
03 FIRE signaling
04 keypad alarms signaling
05
06
07
08
09
keypad FIRE alarm signaling
keypad PANIC alarm signaling
keypad AUX. alarm signaling
sygnalizacja alarmu sabotażowego klawiatury
DAY/NIGHT & COUNTING violation signal.
FS 31 FS 33 FS 35 FS 37 FS 39 FS 41
OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6
TYP WYJŚCIA
Confirm by pressing #
default:
01
01
27
00
22
12
default:
00
00
00
00
00
00
CZAS DZIAŁANIA WYJŚCIA
OPTIONS (turn on light indicator to activate option)
Confirm by pressing #
Output assigned to partition 1
1
Output assigned to partition 2
2
Output assigned to partition 3
3
Output assigned to partition 4
4
Pulsed output
5
Cut-off time in minutes
6
LATCH type output
7
Polarity +12V
8
Confirm by pressing #
10 DURESS signaling
11 CHIME signaling
12 switch MONO ([CODE][*][7])
13 switch BI ([CODE][*][8])
14 arm status (OR)
15 silent arm status
16 EXIT DELAY warning
17 ENTRY DELAY warning
18 telephone usage status
19 GROUND START pulse
20 monitoring acknowledgement
21 zone BYPASS status
22 READY status
23 zone violation status
24 telephone line fault
25 AC loss
26 battery failure
27 power supply
28 fire detectors power supply
29 power supply with RESET function
30 TIMER controlled
31 audible arm status
32 full arm status (AND)
33 arm/disarm beep
34 keypad alarm status
35 power supply in armed mode
36/37 state signals (East European standard)
38 zone failure status
39 no guard code in partition
40 service mode status
41 low battery indicator
CA-10 plus SATEL - Programming List
8
FS 32÷42 - ZONES CONTROLLING OUTPUTS
Lists of zones controlling outputs
FS 32
OUT 1
FS 34
OUT 2
FS 36
OUT 3
FS 38
OUT 4
FS 40
OUT 5
FS 42
OUT 6
ZONE 1
1
1
1
1
1
1
ZONE 2
2
2
2
2
2
2
ZONE 3
3
3
3
3
3
3
ZONE 4
4
4
4
4
4
4
ZONE 5
5
5
5
5
5
5
ZONE 6
6
6
6
6
6
6
ZONE 7
7
7
7
7
7
7
ZONE 8
8
8
8
8
8
8
ZONE 9
1
1
1
1
1
1
ZONE 10
2
2
2
2
2
2
ZONE 11
3
3
3
3
3
3
ZONE 12
4
4
4
4
4
4
ZONE 13
5
5
5
5
5
5
ZONE 14
6
6
6
6
6
6
ZONE 15
7
7
7
7
7
7
ZONE 16
8
8
8
8
8
8
Confirm by pressing #
Confirm by pressing #
Note:
The list of zones may be empty
(default setting). If this is the case,
the output will respond to violation
of any zone, the function of which
corresponds to the output type (for
example, the output which signals
burglary alarms will not respond to
a violation of the 24H FIRE zone).
Similarly, it is not necessary to
enter a partition number in output
options, because in this case the
output responds to all zones,
irrespective of their partition
assignments.
If zones and partitions are
indicated, than the output will be
responding only to the indicated
zones, and alarm clearing will be
possible in the indicated partitions
only.
CA-10 plus SATEL - Programming List
9
FS 43 - MONITORING STATION 1 TELEPHONE NUMBER
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#
maximum 16 characters 0–F; A=end of number, B=pulse dial, C=tone dial, D=wait for continuous tone , E=short pause, F=long pause
FS 44 - MONITORING STATION 2 TELEPHONE NUMBER
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 45 - STATION 1 FORMAT
FS 46 - STATION 2 FORMAT
|__|__|#
|__|__|#
00
01
02
03
04
05
06
07
08
-
Silent Knight, Ademco slow
Sescoa, Franklin, DCI, Vertex
Silent Knight fast
Radionics 1400Hz
Radionics 2300Hz
Radionics with parity 1400Hz
Radionics with parity 2300Hz
Ademco Express
Silent Knight, Ademco slow, extended
|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#
09
0A
0B
0C
0D
8D
0E
0F
-
Sescoa, Franklin, DCI, Vertex, extended
Silent Knight fast, extended
Radionics 1400Hz, extended
Radionics 2300Hz, extended
Telim with entry tone
- Telim without entry tone
Contact ID selected codes
Contact ID all codes
FS 47 - MONITORING OPTIONS (turn on light indicator to activate the option).
1
report to STATION 1 only, with no event sorting
2
report to STATION 2 only, with no event sorting
3
sort events by identifiers during transmission to STATION 1
4
sort events by identifiers during transmission to STATION 2
5
extend single character partition event codes by adding the user number
6
extend single character zone event codes by adding the zone number
NOTE:
7
8
the panel skips sending the event code if STATION 1 fails to
acknowledge receiving the information after 16 attempts
the panel skips sending the event code if STATION 2 fails to
acknowledge receiving the information after 16 attempts
If both controls 1 and 2 are off - the panel
will report to either station 1 or 2 (whichever
is reached first), with no event sorting.
If both controls 1 and 2 are on - the panel
will report to both station 1 and 2, with event
sorting.
CA-10 plus SATEL - Programming List
FS 48 - MONITORING STATION 1 ZONE EVENTS IDENTIFIER
FS 49 - MONITORING STATION 1 PARTITION 1 EVENTS IDENTIFIER
FS 50 - MONITORING STATION 1 PARTITION 2 EVENTS IDENTIFIER
FS 51 - MONITORING STATION 1 PARTITION 3 EVENTS IDENTIFIER
FS 52 - MONITORING STATION 1 PARTITION 4 EVENTS IDENTIFIER
FS 53 - MONITORING STATION 1 SYSTEM EVENTS IDENTIFIER
FS 54 - MONITORING STATION 2 ZONE EVENTS IDENTIFIER
FS 55 - MONITORING STATION 2 PARTITION 1 EVENTS IDENTIFIER
FS 56 - MONITORING STATION 2 PARTITION 2 EVENTS IDENTIFIER
FS 57 - MONITORING STATION 2 PARTITION 3 EVENTS IDENTIFIER
FS 58 - MONITORING STATION 2 PARTITION 4 EVENTS IDENTIFIER
FS 59 - MONITORING STATION 2 SYSTEM EVENTS IDENTIFIER
10
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
Notes: - Use characters 1 ÷ 9 and A ÷ F when programming the identifiers. In case of three-character identifiers, program the fourth character as 0 (zeros
are not transmitted)
- If the monitoring station requires an identifier containing zero, program “A” instead of “0” (e.g. enter 12A3 instead of 1203).
CA-10 plus SATEL - Programming List
11
FS 60÷66 - ZONE REPORT CODES.
Zones
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FS 60 - ALARM CODES
FS 61 - ZONE TAMPER CODES
FS 62 - ZONE TROUBLE CODES
FS 63 - ZONE VIOLATION CODES
FS 64 - ZONE RESTORE CODES
FS 65 - TAMPER RESTORE CODES
FS 66 - TROUBLE RESTORE CODES
FS 134 – ZONE BYPASS CODES
FS 135 – ZONE UNBYPASS CODES
Confirm each code by pressing #. Zone numbers are indicated by LEDs 9÷12.
FS 67, 68 - ZONE EVENTS ASSIGNMENT TO MONITORING STATIONS.
FS 67
FS 68
ZONE ALARM CODES
SEND TO
SEND TO
STATION 1
1
STATION 2
1
ZONE TAMPER ALARM CODES
2
2
ZONE TROUBLE CODES
3
3
ZONE VIOLATION CODES
4
4
ZONE RESTORE CODES
5
5
TAMPER RESTORE CODES
6
6
TROUBLE RESTORE CODES
7
7
ZONE BYPASS AND UNBYPASS CODES
8
8
By default, all codes are equal to 00.
Confirm by pressing #
Note:
No events with 00 code are reported. Singlecharacter codes are obtained by programming one
of the characters as 0.
The mode of reporting to both stations with event
sorting requires that event assignment to central
stations be programmed. Events with no assignment
will not be reported even if their report codes have
been programmed.
16
CA-10 plus SATEL - Programming List
12
FS 69÷72 - PARTITION EVENT CODES
Numer kodu wskazywany na diodach LED 9÷12
EVENT CODES:
1
ARMING
*
2
SILENT ARMING
*
3
ARMING WITH BYPASS
*
4
CLEARING ALARM
*
5
DISARMING
*
6
do not program
7
SYSTEM CLOCK PROGRAMMING
*
8
ZONE BYPASS
*
9
KEYPAD FIRE ALARM
10
KEYPAD PANIC ALARM
11
KEYPAD AUX. ALARM
12
KEYPAD TAMPER ALARM
13
3 INCORRECT CODES ALARM
14
DISARMING WITH A DURESS CODE
15
INTERIOR PARTITION ARMING
16
INTERIOR PARTITION DISARMING
FS-69
FS-70
FS-71
FS-72
PARTITION 1
PARTITION 2
PARTITION 3
PARTITION 4
Note: Codes marked with * can be extended by the panel with the user number (see FS47). For example, if the ARMING code is programmed as 10, the panel
will report code 11 on arming the partition by User 1, code 12 on arming by User 2, etc.
CA-10 plus SATEL - Programming List
13
FS 73÷80 – PARTITION EVENTS ASSIGNMENT TO MONITORING STATIONS.
EVENTS REPORTED TO
EVENTS REPORTED TO
STATION 1
STATION 2
FS-73 FS-74 FS-75 FS-76
FS-77 FS-78 FS-79 FS-80
ARMING
1
SILENT ARMING
2
ARMING WITH BYPASS
3
CLEARING ALARM
4
DISARMING
5
do not program
6
SYSTEM CLOCK PROGRAMMING
7
ZONE BYPASS
8
Confirm by pressing #
KEYPAD FIRE ALARM
1
KEYPAD PANIC ALARM
2
KEYPAD AUX. ALARM
3
KEYPAD TAMPER ALARM
4
3 INCORRECT CODES ALARM
5
DISARMING WITH DURESS CODE
6
INTERIOR PARTITION ARMING
7
INTERIOR PARTITION DISARMING
8
Confirm by pressing #
PART.
PART.
PART.
PART.
PART.
PART.
PART.
PART.
1
2
3
4
1
2
3
4
CA-10 plus SATEL - Programming List
14
FS 81÷84 – SYSTEM EVENTS CODES AND ASSIGNMENT TO MONITORING STATIONS.
EVENTS
ASSIGNMENT
SYSTEM EVENTS – SET I
1
2
3
4
5
6
7
8
9
FS 81
FS 83
FS 84
EVENT
CODES
SEND TO
SEND TO
SYSTEM EVENTS – SET II
STATION 1 STATION 2
AC LOSS
1
OUTPUT OUT 4 TROUBLE
2
OUTPUT OUT 4 RESTORE
3
TRANSMISSION PROBLEMS
4
EVENT LOG OVERFLOW
5
LOSS OF TIME
6
RAM MEMORY FAULT
7
SYSTEM RESTART
8
TEST TRANSMISSION
9
KEYPAD POWER SUPPLY TROUBLE
10
KEYPAD POWER SUPPLY RESTORE
FS 82
EVENT
CODES
AC RESTORE
LOW BATTERY
BATTERY RESTORE
OUTPUT OUT 1 TROUBLE
OUTPUT OUT 1 RESTORE
OUTPUT OUT 2 TROUBLE
OUTPUT OUT 2 RESTORE
OUTPUT OUT 3 TROUBLE
10 OUTPUT OUT 3 RESTORE
11 PRINTER TROUBLE
12 PRINTER RESTORE
13 ENTER SERVICE MODE
14 EXIT SERVICE MODE
15 DOWNLOADING - START
16 DOWNLOADING - END
NOTE: When monitoring with events sorting is enabled,
the system events, set II, are always sent to both stations.
CA-10 plus SATEL - Programming List
15
FS 85 – TIME OF TEST TRANSMISSION TO MONITORING STATION
|__|__|#|__|__|#
|9|9|#|9|9|#
|__|__|#
|1|0|#
Program from 00:00 to 23:59; the value 99:99 disables sending the transmission test..
FS 86 - AC LOSS REPORT DELAY (01-99 minutes)
FS 87 - TELEPHONE NUMBER 1
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 88 - TELEPHONE NUMBER 2
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 89 - TELEPHONE NUMBER 3
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 90 - TELEPHONE NUMBER 4
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 91 - TELEPHONE NUMBER 5
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 92 - TELEPHONE NUMBER 6
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 93 - TELEPHONE NUMBER 7
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
FS 94 - TELEPHONE NUMBER 8
|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#|__|__|#
max.16 characters 0 to F,
A=end of number,
B=pulse dial,
C=tone dial,
D=wait for the continuous tone ,
E=short pause,
F=long pause.
by default, all telephone numbers are deleted = |A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#|A|A|#
NOTE: Do not put the special characters B÷F before the telephone number, as they are used for
introducing changes during dialing. The basic mode of dialing and the telephone line signal test are
enabled in FS 5.
CA-10 plus SATEL - Programming List
16
FS 95 - PARTITIONS AND MESSAGES ASSIGNMENT TO TELEPHONE NUMBERS
LEDs 9÷12
TELEPHONE NUMBER:
1
2
3
4
5
6
7
8
NOTE:
1 Partition 1
- a LED comes on when partition or
message has been selected;
2 Partition 2
LEDs 1÷8
3 Partition 3
- if no pager message assignment is
made, the message will be sent by a
voice synthesizer.
4 Partition 4
5 Message no 1 (PAGER)
6 Message no 2 (PAGER)
7 Message no 3 (PAGER)
8 Message no 4 (PAGER)
confirm with # key
FS 96 - PAGER MESSAGE 1 (also FS 119)
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
FS 97 - PAGER MESSAGE 2 (also FS 120)
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
CA-10 plus SATEL - Programming List
17
FS 98 - PAGER MESSAGE 3 (also FS 121)
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
FS 99 - PAGER MESSAGE 4 (also FS 122)
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|
|__|__|#
FS 100 - PROGRAMMING NUMBER OF ATTEMPTS AND MESSAGE QUEUES
number of attempts (0-9) Ê
FS 101 - RINGS BEFORE ANSWER (00 to 09)
FS 102 - TIMER 1
SWITCH ON at (hours/minutes)
SWITCH OFF at (hours/minutes)
FS 103 - TIMER 2
SWITCH ON at (hours/minutes)
SWITCH OFF at (hours/minutes)
FS 104 - TIMER 3
SWITCH ON at (hours/minutes)
SWITCH OFF at (hours/minutes)
FS 105 - TIMER 4
SWITCH ON at (hours/minutes)
SWITCH OFF at (hours/minutes)
|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|__|__|#|__|__|#
|4|2|#
É number of queues (1-7)
|0||0|#
Default OFF: |9|9||9|9|
|9|9||9|9|
|9|9||9|9|
|9|9||9|9|
|9|9||9|9|
|9|9||9|9|
|9|9||9|9|
|9|9||9|9|
CA-10 plus SATEL - Programming List
18
TIMER FUNCTIONS:
0 - timer not used
1 - controls output OUT 1
2 - controls output OUT 2
3 - controls output OUT 3
4 - controls output OUT 4
5 - controls output OUT 5
6 - controls output OUT 6
7 – partition control
FS 106 - TIMER FUNCTIONS
TIMER 1
TIMER 2
Confirm by pressing #
TIMER 3
TIMER 4
8 - arms/disarms partition 1
9 - arms/disarms partition 2
A - arms/disarms partition 3
B - arms/disarms partition 4
NOTE: for partition control function (7) timer
1 controls partition 1, timer 2 - partition 2 etc.
Confirm by pressing #
FS 107 - RESTORING DEFAULT SETTINGS
FS 108 - CLEARING EVENT LOG
FS 109 - PROGRAMMING DEFAULT IDENTIFICATION CODES
FS 110 - RESTORING DEFAULT CODES
FS 111 - PROGRAMMING KEYPAD ADDRESSES
Address of keypad 2
Confirm by pressing #
1
A
1
A
2
B
2
B
3
C
3
C
4
D
4
D
5
A
5
A
6
B
6
B
7
C
7
C
8
D
8
D
Address of keypad 3
LED No.
keypad jumpers
LED No.
Address of keypad 1
Keypads 3 & 4 (LED 11 blinking)
Address of keypad 4
Confirm by pressing #
keypad jumpers
Keypads 1& 2 (LED 12 blinking)
NOTE: The illuminated
LEDs indicate position of
keypad jumpers.
CA-10 plus SATEL - Programming List
19
FS 112 - START OF PROGRAMMING THROUGH RS-232
FS 113 - START OF PRINTING EVENT LOG
FS 114 - START OF PRINTING ALARM LOG
FS 115 - START OF PRINTING TROUBLE LOG
FS 116 - START OF PRINTING PARTITIONS EVENT LOG
|__|__|#
FS 117 - TELEPHONE LINE LOSS DELAY. (00 to 99 minutes)
|0|0|#
FS 118 - PAGER MESSAGE RECEIVER PARAMETERS
program:
|3|B|#|4|2|#|0|B|#|0|F|#|1|0|#|8|0|# for POLPAGER system
|2|B|#|2|E|#|0|E|#|1|4|#|3|0|#|3|A|# for TELEPAGE system
|3|7|#|3|D|#|0|7|#|0|B|#|B|6|#|C|8|# for EASY CALL system
|1|6|#|1|A|#|1|3|#|1|7|#|0|B|#|0|F|# for METRO-BIP system
|__|
|__|
|__|
|__|
FS 119÷122 - PROGRAMMING MESSAGES TO PAGER (also FS 96 to FS 99)
FS 123 – COUNTING ZONES COUNT TIMES
COUNTER
1
2
Default:
3
NOTE: Program times: 0 to 255 seconds
COUNTING TIME
|3|0|#|3|0|#|3|0|#
CA-10 plus SATEL - Programming List
FS 124 - KEYPAD ADDRESSES AUTO-DETECT
FS 125 – OUTPUTS TESTING
FS 126 - PARTITION CONTROL MONITORING CODES
Partition 1 input/output (entering Partition 1 control code)
Partition 2 input/output (entering Partition 2 control code)
Partition 3 input/output (entering Partition 3 control code)
Partition 4 input/output (entering Partition 4 control code)
No control code - Partition 1
No control code - Partition 2
No control code - Partition 3
No control code - Partition 4
FS 127÷130 - ZONES AUTO-BYPASSED ON NO EXIT FROM THE FACILITY (see page 3)
20
CA-10 plus SATEL - Programming List
21
FS 131 - PROGRAMMING ADDITIONAL OPTIONS
FIRST SET (LED 12 blinking)
SECOND SET (LED 11 blinking)
1
Service mode disabled
1
No arming during battery failure
2
DTMF module control allowed (MST-1)
2
Automatic counters reset at midnight „AUTORESET 1/3”
3
Pulse dialing ratio 1:1,5
3
Service Mode in one partition only
4
Global access codes
4
Service message after tamper alarm
5
Partition 1 timer priority
5
Trouble clear
6
Partition 2 timer priority
6
Audible tamper alarm only in arming
7
Partition 3 timer priority
7
Alarms number limitation down to 3 from a zone
8
Partition 4 timer priority
8
do not program
Confirm by pressing #.
Confirm by pressing #.
FS 132 - PROGRAMMING OF CLOCK CORRECTION
program:
01 do 19
81 do 99
|__|__|#
- positive value 1s do 19s
- negative value -1s do -19s
|0|0|#
00
- no correction
FS 133 – TIME OF TEST TRANSMISSION TO THE MONITORING STATION
|__|__|#|__|__|#|__|__|# after last transmission.
days
hours
minutes
Default : |0|0|#|0|0|#|0|0|#
FS 134 – ZONE BYPASS CODES (see p. 11)
FS 135 – ZONE UNBYPASS CODES (see p. 11)
FS-136 - PREFIX FOR EXTENSION OF IDENTIFIERS IN “TELIM” TRANSMISSION FORMAT
FS 137 – CODES USED IN “TELIM” TRANSMISSION FORMATS