Data Management and Access Products - Mercado

Data Management and Access Products
Data Management and Access Products
General Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Summary of Data Management and Access Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
PatchMate™ Introduction and Product Summary
About PatchMate Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
PatchMate Decision Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
PatchMate Assemblies At A Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
PatchMate Modules At A Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
PatchMate™ EIA-530 Products
EIA-530 Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
EIA-530 Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
EIA-530 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
EIA-530 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
EIA-530 Patch Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
PatchMate™ EIA-232/V.24 Products
EIA-232/V.24 Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
EIA-232/V.24 Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
EIA-232/V.24 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
EIA-232/V.24 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
EIA-232/V.24 Patch Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
PatchMate™ V.35 Products
V.35 Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
V.35 Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
V.35 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
V.35 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
V.35 Patch Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
PatchMate™ EIA-422/V.11 (X.27) Products
EIA-422/V.11 (X.27) Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
EIA-422/V.11 (X.27) Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
EIA-422/V.11 (X.27) Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
EIA-422/V.11 (X.27) Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
EIA-422/V.11 (X.27) Patch Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
PatchMate™ Ancillary Equipment and Accessories
PatchMate Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
PatchMate Powered and Unpowered Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Chassis Compatibility Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
PatchMate Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
12/02
•
517
Data Management and Access Products
Table of Contents
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Data Management and Access Products
PatchSwitch™ Introduction and Product Summary
About PatchSwitch Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PatchSwitch Decision Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
PatchSwitch Assemblies At A Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
PatchSwitch Modules At A Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
PatchSwitch™ Products
PatchSwitch Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
PatchSwitch Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
PatchSwitch Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
PatchSwitch Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
EIA-530 Patch Cords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
PatchSwitch™ Ancillary Equipment and Accessories
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Specifications
PatchMate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
PatchSwitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
12/02
•
517
Data Management and Access Products
Table of Contents
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Data Management and Access Products
12/02
•
517
Data Management and Access Products
Introduction
Uninterrupted data network communications depend
upon your ability to independently and immediately
restore function to a failed component or to substitute
or reroute communication paths. ADC's PatchMate™
and PatchSwitch™ data management and access
products provide a convenient, organized method of
digital communications line monitoring and
reconfiguration. Products have been designed to meet
the needs of a wide variety of applications. The most
commonly used products are described in this catalog.
Features:
Built-in circuit diagnostic aids
• Quick isolation of circuit problems
• Rapid restoration of critical circuit paths
• Routine "at a glance" visibility of basic network health and activity (without instruments)
Rugged, fail-safe design
• High quality and innovative design assures absolute integrity of circuit
• Lifetime warranty on all patch mechanisms and cords
• No sliding, hinged or rotating mechanical parts
Compact size and flexible configuration
• More features in less space compared to typical competitive methods
• Wide range of accessory modules and maximum customization
High Reliability and Quality
Primary Use
• Data management and access products are
designed and manufactured to provide high
reliability and quality.
• ADC is ISO 9000 certified
• Patented spring contact to spring contact
patching connections give solid
contact operation.
• Contacts are bifurcated and gold inlaid to
prevent wear, oxidation or material
breakdown.
• Contacts on both the patch modules and
patch cords are fully recessed to prevent
breakage, contamination or inadvertant
shorting.
• Patch cords are keyed to prevent improper
insertion and are fully strain relieved.
• All patch module mounting hardware is
captive on the module itself, so there is no
fumbling for dropped or lost parts.
• End user, government, private and
international data communications networks
for patching, testing, access and
reconfiguration.
w w w. a d c . c o m
•
• Data networks with a revenue-related
function or high strategic value
• Perform the same function on data
communications circuits that DSX or
bantam jackfields perform on T1 or analog
telecommunications circuits.
• Indicate circuit health with alarms and LEDs
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
1
Data Management and Access
Components
12/02
•
517
Data Management and Access Products
Assemblies
Prepackaged combinations of the various components that make up the full
PatchMate or PatchSwitch patch panel. Most assemblies contain 16 digital
patch modules in the leftmost 16 positions of an 18 position chassis. Each
assembly comes with a blank designation labeling strip that is 18 modules
wide, or the entire width of the chassis.
Keyway
Patch Modules
Each standard module contains three front panel jacks for easy passive and/or
intrusive access to the circuit and two rear connectors for attachment to data
terminating and/or communication devices. Insertion of a patch cord into the
monitor jack allows the circuit to be monitored without interruption.
Key Type A
Most modules have standard keying; however reverse keyed modules are
available in the EIA-530 and EIA-422/V.11 (X.27) product lines. The difference
between the two designs lies in the location of the patch cord key way. In
standard versions (Key Type B), the key way is located in the upper right corner
of the patch jack. Reverse keyed (Key Type A) modules have the key way
located in the lower right. The different placement of the key ways makes it
impossible to patch between the two types with standard patch cords,
eliminating the potential for disruption of critical or incompatible circuits.
When Key Type A modules are used, reverse keyed patch cords are required.
Keyway
Breakout Modules
Used to alter or reconfigure the serial binary data interchange signal paths for
the circuit leads between the DTE and DCE interface within the digital patch
field. They also provide switches to open/close circuit path pin jacks on both
sides of the interface for test/injection on up to 24 leads.
Key Type B
Interface Modules
Allow test equipment and/or spare terminal or communications equipment
(e.g., spare modem or computer ports) to be easily accessed and terminated
within the digital patch field.
Test Modules
Provide diagnostic equipment interface capabilities and status monitoring for
circuit activity and alarm conditions. Allows external test equipment or other
miscellaneous equipment to be terminated and accessed within the digital
patch field.
Chassis
Chassis accommodate up to 18 modules of various types. Each chassis comes
complete with two cable strain relief bars, designation cards and designation
windows.
Patch Cords
Patch cords are used to perform the monitoring and patching functions on
various assemblies and modules. In addition, special purpose patch cords are
provided to perform various other functions and special interfacing as might
be required by the user. Patch cords are available in standard and reverse key
types and in a wide variety of lengths.
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
2
PatchMate™ Products
Data Management and Access Products
Introduction
For total control over the network, you need the ability to perform independent and immediate circuit
restoration upon failure or reroute a communications path. PatchMate Digital Patching provides
convenient, organized line monitoring, access, test and reconfiguration capability for multiconductor digital
interfaces.
PatchMate™ Product Line
• Twenty-five leads are patched when using EIA-530, EIA-232/V.24, V.35 and EIA-422/V.11 (X.27)
• PatchMate systems provide physical, hard-contact access to any multiconductor data circuit for the
analysis and restoral of circuit operation
• Capability to tailor alarm monitoring conditions instantly to changing needs without module removal
• PatchMate systems provide flexibility to add or interchange modules on a single line basis
• Design avoids the use of card edge connectors and movable mechanical parts
• Offers more features and benefits than competitive models
• Module mounting hardware is captive to prevent dropped or lost parts
Alarms and LEDS
• "At a glance" circuit diagnostics
• Circuit alarm status indicated locally by an amber LED on the chassis or module
• Up to eight status indicators and alarm circuitry per module
• Green and red LEDs indicate real time status of signal leads
• Instantly tailor alarm monitoring conditions to changing needs without module removal
• Alarming options controlled by a simple toggle switch located on the front of each module
• Choose "Alarm Off", "Audible and Visual Alarm", or "Visual Alarm Only"
• Alarming is on with either the absence or continued presence of an electrical signal
• Select alarm delay from 50 microseconds (µ) to 68 seconds
• Alarm reset by touching two contacts on the front of the module
• Most complete alarm and LED set available
Patch Cords
• Patented spring contact to spring contact provides the most reliable solid connection
• Contacts are gold inlaid and bifurcated to prevent wear, oxidation or material breakdown
• Contacts are fully recessed to prevent breakage or contamination
• Cords are keyed to prevent improper insertion and are fully strain relieved
Chassis
517
• Dip switches on all 24 leads
12/02
• Cable support provided for easy removal of module for internal adjustments
•
• Accommodate up to 18 modules of various types
Breakout Modules
• Pin jacks on both sides of the switches for test/injection
• Test voltage and LEDs for injection/test function
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
PatchMate™ Products
Introduction
What type of interface do you need for patching?
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11 (x.27)
If you need manual network
control capabilities, use this
decision tree to guide you
through the selection of a
complete PatchMate system.
Do you need a fully preconfigured
16 circuit assembly?
YES
NO
Do you need
LEDs or alarms?
YES
Choose Assembly
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11
(X.27)
Do you need
LEDs or alarms?
NO
pg 10
pg 18
pg 27
pg 34
Choose Accessories
EIA-530
pg 12-14
pg 20-23
EIA-232/V.24
V.35
pg 28-30
EIA-422/V.11 (X.27) pg 36-38
NO
pg 10
pg 18
pg 27
pg 34
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11
(X.27)
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11
(X.27)
Choose Accessories
pg 12-14
EIA-530
pg 20-23
EIA-232/V.24
pg 28-30
V.35
EIA-422/V.11 (X.27) pg 36-38
pg 12-14
pg 20-23
pg 28-30
pg 36-38
Choose Chassis
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11 (X.27)
Choose
Power Supply
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11 (X.27)
YES
Choose Modules
Choose Assembly
pg 15
pg 24
pg 31
pg 39
Choose Modules
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11
(X.27)
pg 12-14
pg 20-23
pg 28-30
pg 36-38
Choose Chassis
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11 (X.27)
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11 (X.27)
pg 41
pg 41
pg 41
pg 41
Choose
Patch Cords
EIA-530
EIA-232/V.24
V.35
EIA-422/V.11 (X.27)
pg 16
pg 25
pg 32
pg 40
12/02
•
Choose
Other Accessories
see pages 44-45
PLACE
ORDER
w w w. a d c . c o m
•
pg 15
pg 24
pg 31
pg 39
Choose
Power Supply
517
Data Management and Access Products
PatchMate™ Decision Tree
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
4
pg 41
pg 41
pg 41
pg 41
PatchMate™ Products
P= Plug/Male Connection
R= Receptacle/Female Connector
XX= Length of patch cord
Connector
Catalog
Number
EIA-530
PMS-614001
PMS-614007
PMS-616004
PMS-616004RED
PMS-616005
PMS-616005RED
11
11
11
11
•
12/02
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
P (DB25)
P (DB25)
P (DB25)
P (DB25)
R (DB25)
P (DB25)
Connector
Catalog
Number
Options
Components Included
Page Rear/Top Rear/Bottom
(DCE)
Number (DTE)
LEDs Alarms
No
No
No
No
No
No
Yes
Yes
No
No
No
No
Quantity/Type
Patch Module
Quantity/Type Blank
Other Module Modules Chassis
1
2
2
2
1
1
16 PMM-614001
1 PMM-636003
16 PMM-614001
None
16 PMM-614004
None
16 PMM-616004RED
None
16 PMM-614005
1 PMM-636003
16 PMM-616005RED 1 PMM-636003RED
Options
PMCH-1
PMCH-1
PMCH-2
PMCH-2
PMCH-2
PMCH-2
Components Included
Quantity/Type Quantity/Type Blank
Page Rear/Top Rear/Bottom
(DCE)
Number (DTE)
LEDs Alarms Patch Module Other Module Modules Chassis
EIA-232/V.24
PMSLA-16
PMSLA-16 (G)
PMSLA-16 (R)
PMSLA-16-MF
PMSL-16
PMSL-16-MF
PMS-16
PMS-16-MF
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
19
19
19
19
19
19
R (DB25)
R (DB25)
R (DB25)
P (DB25)
R (DB25)
P (DB25)
R (DB25)
P (DB25)
Connector
Catalog
Number
V.35
PMSLA-16-V35FF
PMSLA-16-V35
PMS-16-V35FF
PMS-16-V35
(R) V.35
(R) V.35
(R) V.35
(R) V.35
27
27
27
27
(R) V.35
(P) V.35
(R) V.35
(P) V.35
Connector
Catalog
Number
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
No
No
No
16 PMMLA-1
16 PMMLA-1
16 PMMLA-1
16 PMMLA-2
16 PMML-1
16 PMML-2
16 PMM-1
16 PMM-2
Options
None
None
None
None
None
None
None
None
2
2
2
2
2
2
2
2
PMCH-1
PMCH-1
PMCH-1
PMCH-1
PMCH-1
PMCH-1
PMCH-2
PMCH-2
Components Included
Page Rear/Top Rear/Bottom
Quantity/Type Quantity/Type Blank
(DCE)
Number (DTE)
LEDs Alarms Patch Module Other Module Modules Chassis
517
Data Management and Access Products
Assemblies At A Glance
Yes
Yes
No
No
Yes
Yes
No
No
16 PMMLA-V35FF
16 PMMLA-V35
16 PMM-V35FF
16 PMM-V35
Options
None
None
None
None
2
2
2
2
PMCH-1
PMCH-1
PMCH-2
PMCH-2
Components Included
Page Rear/Top Rear/Bottom
Quantity/Type Quantity/Type Blank
(DCE)
Number (DTE)
LEDs Alarms Patch Module Other Module Modules Chassis
EIA-422/V.11 (X.27)
PMS-B-16-MF
PMS-B-16-MF (R)
PMS-616002
w w w. a d c . c o m
(P) DB25
(P) DB25
(P) DB25
35
35
•
(R) DB25
(R) DB25
(R) DB25
No
No
No
No
No
No
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
16 PMM-B-2
16 PMM-B-2 (R)
16 PMM-616002
•
None
None
None
1 - 8 0 0 - 3 6 6 - 3 8 9 1
2
2
2
PMCH-2N
PMCH-2N
PMCH-2N
5
PatchMate™ Products
LED breakout and test modules require power supply DMPS-11 or DMPS-11E when used in
unpowered chassis PMCH-2 or PMCH-2N.
Required Components
Optical Components
Power Supply
Patch Cords
Compatible
Interface Modules
Compatible
Test Modules
Compatible
Breakout Modules
DMPS-5A
DMPS-5A
N/A
N/A
N/A
N/A
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
None
None
None
None
None
None
PMM-636003 included
PMM-636003
PMM-636003
PMM-636003RED
PMM-636003 included
PMM-636003RED
PMBP-530-1or PMBP-530-2
PMBP-530-1or PMBP-530-2
PMBP-530-1or PMBP-530-2
PMBP-530-1or PMBP-530-2
PMBP-530-1or PMBP-530-2
PMBP-530-1or PMBP-530-2
Required Components
Power Supply
Optical Components
Patch Cords
Compatible
Interface Modules
Compatible
Test Modules
Compatible
Breakout Modules
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PIMMLA-1
PIMMLA-1
PIMMLA-1
PIMMLA-1
PIMMLA-1
PIMMLA-1
PMME-1
PMME-1
PIMMLA-2
PIMMLA-2
PIMMLA-2
PIMMLA-2
PIMMLA-2
PIMMLA-2
PMME-2
PMME-2
PMBP-1or PMBP-2
PMBP-1or PMBP-2
PMBP-1or PMBP-2
PMBP-1or PMBP-2
PMBP-1or PMBP-2
PMBP-1or PMBP-2
PMBP-1or PMBP-2
PMBP-1or PMBP-2
DMPS-5, 5E or 548
DMPS-5, 5E or 548
DMPS-5, 5E or 548
DMPS-5, 5E or 548
DMPS-5, 5E or 548
DMPS-5, 5E or 548
N/A
N/A
Required Components
Optical Components
Power Supply
Patch Cords
Compatible
Interface Modules
Compatible
Test Modules
Compatible
Breakout Modules
DMPS-5, 5E or 548
DMPS-5, 5E or 548
N/A
N/A
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PIMMLA-V35
PIMMLA-V35
PMME-V35
PMME-V35
None
None
None
None
None
None
None
None
517
Data Management and Access Products
Introduction
Required Components
Optical Components
Patch Cords
Compatible
Interface Modules
Compatible
Test Modules
Compatible
Breakout Modules
N/A
N/A
N/A
PMPC-B-X
PMPC-B-X
PMP-6XX002
None
None
None
PIMML-B-2
PIMML-B-2
PMM-636003
PMBP-1
PMBP-1
PMBP-1
12/02
•
Power Supply
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
6
PatchMate™ Products
12/02
•
517
Data Management and Access Products
Modules At A Glance
P= Plug/Male Connection
R= Receptacle/Female Connector
XX= Length of patch cord
“Top” connector is on front of test module
Connector
Catalog
Number
Page
Number
EIA-530
PMM-614001
PMM-616001
PMM-616004
PMM-616004RED
PMM-616005
PMM-636001
PMM-636002
PMM-636003
PMM-636003RED
PMME-5
PMPB-530-2
Rear/Bottom
(DCE)
PMS-614001/7
None
PMS-616004
PMS-616004RED
None
PMS-616005RED
None
PMS-614001/6005
PMS-616005RED
None
None
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
P (DB25)
P (DB25)
P (DB25)
P (DB25)
R (DB25)
R (DB25)
R (DB25)
Patch
Patch
Patch
Patch
Patch
Patch
Patch-Red
Interface
Interface
Test
Test
Breakout
Breakout
PMSLA-16
PMSLA-16-MF
PMSL-16
PMSL-16-MF
PMS-16
PMS-16-MF
PMS-16-MF
None
None
None
None
None
None
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
P (DB25)
R (DB25)
R (DB25)
P (DB25)
R (DB25)
P (DB25)
R (DB25)
P (DB25)
P (DB25)
R (DB25)
R (DB25)
29
29
29
29
30
30
Patch
Patch
Patch
Patch
Interface
Interface
PMSLA-16-V35FF
PMSLA-16-V35
PMS-16-V35FF
PMS-16-V35
None
None
R (V.35)
R (V.35)
R (V.35)
R (V.35)
R (V.35)
R (V.35)
R (V.35)
P (V.35)
R (V.35)
P (V.35)
R (V.35)
R (V.35)
37
37
37
Interface
Patch
Patch
Patch
Patch
Interface
Test
None
PMSL-B-17
PMS-B-17
PMS-B-16-MF (R)
PMS-616002
None
None
R (DB25)
P (DB25)
P (DB25)
R (DB25)
P (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
P (DB25)
R (DB25)
R (DB25)
R (DB25)
Loaded Chassis
Patch
Patch
Patch
Patch
Patch
Test
Test
Test
Test
Interface
21
21
21
21
21
21
21
21
21
21
21
21
13
13
13
13
13
14
14
EIA-232/V.24
PMMLA-1
PMMLA-2
PMML-1
PMML-2
PMM-1
PMM-2
PMM-2 (R)
PIMMLA-1
PMME-1
PIMMLA-2
PMME-2
PMPB-2
PMBP-1
V.35
PMMLA-V35FF
PMMLA-V35
PMM-V35FF
PMM-V35
PIMMLA-V35
PMME-V35
EIA-422/V.11 (X.27)
PMME-B-1
PMML-B-2
PMM-B-2
PMM-B-2 (R)
PMM-616002
PIMML-B-1
PIMML-B-2
w w w. a d c . c o m
Rear/Top
(DTE)
Module Type
37
38
38
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
R (DB25)
7
PatchMate™ Products
12/02
•
517
Data Management and Access Products
Modules At A Glance
*LED breakout and test modules require power supply DMPS-11 or DMPS-11E when used in the
unpowered chassis PMCH-2 and PMCH-2N
Connector
Catalog
Number
LEDs
Alarms
Chassis
Patch Cords
Other
EIA-530
PMM-614001
PMM-616001
PMM-616004
PMM-616004RED
PMM-616005
PMM-636001
PMM-636002
PMM-636003
PMM-636003RED
PMME-5
PMPB-530-2
PMPB-530-1
Yes
No
No
No
No
No
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
PMCH-1
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2*
PMCH-1 or 2
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
None
None
None
None
None
None
None
None
None
None
None
None
EIA-232/V.24
PMMLA-1
PMMLA-2
PMML-1
PMML-2
PMM-1
PMM-2
PMM-2 (R)
PIMMLA-1
PMME-1
PIMMLA-2
PMME-2
PMPB-2
PMBP-1
Yes
Yes
Yes
Yes
No
No
No
Yes
No
Yes
No
Yes
No
Yes
Yes
No
No
No
No
No
Yes
No
Yes
No
No
No
PMCH-1
PMCH-1
PMCH-1
PMCH-1
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1
PMCH-1 or 2
PMCH-1 or 2*
PMCH-1 or 2
PMCH-1 or 2*
PMCH-1 or 2
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
None
None
None
None
None
None
None
None
None
None
None
None
None
V.35
PMMLA-V35FF
PMMLA-V35
PMM-V35FF
PMM-V35
PIMMLA-V35
PMME-V35
Yes
Yes
No
No
Yes
No
Yes
Yes
No
No
Yes
No
PMCH-1
PMCH-1
PMCH-1 or 2
PMCH-1 or 2
PMCH-1
PMCH-1 or 2
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
BKT-V35
BKT-V35
BKT-V35
BKT-V35
BKT-V35
BKT-V35
EIA-422/V.11 (X.27)
PMME-B-1
PMML-B-2
PMM-B-2
PMM-B-2 (R)
PMM-616002
PIMML-B-2
No
Yes
No
No
No
Yes
No
No
No
No
No
No
PMCH-2N or 6
PMCH-6
PMCH-2N or 6
PMCH-2N or 6
PMCH-2N or 6
PMCH-2N* or 6
PMPC-B-X
PMPC-B-X
PMPC-B-X
PMPC-B-X
PMP-6XX002
PMPC-B-X
None
None
None
None
None
None
Note: PMCH-1 Chassis requires power supply
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
8
The EIA-530 interface has become an industry standard for many reasons. Users and vendors of EIA-232,
V.35, EIA-422 and EIA-449 data communications equipment are migrating to EIA-530 to take advantage of
the higher data rate and the compact mechanical interface. A unique patch port pin configuration is
responsible for ADC's PatchMate EIA-530's superior electrical performance characteristics.
EIA-530 Summary
• Patches 25 leads
• Data rates of DC to 5 Mbps (LED modules) and to 20 Mbps (non-LED modules)
• DB25 connector interface
• Key Type A
• Patch cord (PMP-6XX007) available in 02-10 foot lengths
• Balanced or unbalanced operation available at user discretion
• Modules and patch cords are grey
Pin
Abbreviation
Description
1
Shield
Shield
2
TD (A)
Transmitted Data
Green/Red
3
RD (A)
Received Data
Green/Red
4
RS (A)
Request to Send
Green/Red
5
CS (A)
Clear to Send
Green/Red
6
RR (A)
DCE Ready
Green/Red
7
SG
Signal Ground
8
DM (A)
Received Line Signal Detector
Green/Red
9
RT (B)
Receive Signal Element Timing
Green/Red
10
DM (B)
Received Line Signal Detector
Green/Red
11
TT (B)
Transmit Signal Element Timing (DTE)
Green/Red
12
TT (B)
Transmit Signal Element Timing (DCE)
Green/Red
13
CS (B)
Clear to Send
Green/Red
14
TD (B)
Transmitted Data
Green/Red
15
TT (A)
Transmit Signal Element Timing (DCE)
Green/Red
16
RD (B)
Received Data
Green/Red
517
EIA -530 Pin Chart
17
RT (A)
Receive Signal Element Timing
Green/Red
18
LL
Local Loopback
•
Data Management and Access Products
EIA-530 PatchMate™
19
RS (B)
Request to Send
Green/Red
20
TR (A)
DTE Ready
Green/Red
21
RL
Remote Loopback
22
RR (B)
DCE Ready
Green/Red
23
TR (B)
DTE Ready
Green/Red
24
TT (A)
Transmit Signal Element Timing (DTE)
Green/Red
25
TM
Test Mode
1
14
15
16
17
18
19
20
21
22
23
24
25
2
3
4
5
LEDs
6
7
8
9
10
11
12
12/02
13
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
9
EIA-530 PatchMate™
Assemblies
• Weight: 13 lbs (6 kg)
• Patches 25 leads
• Data rate of DC to 5 Mbps (LED modules) and 20 Mbps (non-LED modules)
• DB25 connector interface
• Key Type A
• Patch cord (PMP-6XX007) available in 02-10 foot lengths
• Balanced or unbalanced operation available at user discretion
• Modules and patch cords are grey
Assemblies with LEDs
• Front panel mounted tri-color LEDs provide passive monitoring of the circuit leads
terminated to the patch module (see LED chart)
• Green LEDs represent an asserted signal on the lead
• Red LEDs represent a non-asserted signal on the lead
• Clear LEDs represent a disconnected/ inadequate signal on the lead
EIA -530 LED Chart
Pin A
Pin B
Abbreviation
Description
LEDs
2
14
TD
Transmitted Data
Green/Red
3
16
RD
Received Data
Green/Red
4
19
RS
Request to Send
Green/Red
5
13
CS
Clear to Send
Green/Red
6
22
RR
DCE Ready
Green/Red
8
10
DM
Received Line Signal Detector
Green/Red
15
12
TT
Transmit Signal Element Timing (DCE)
Green/Red
17
9
RT
Receive Signal Element Timing
Green/Red
20
23
TR
DTE Ready
Green/Red
24
11
TT
Transmit Signal Element Timing (DTE)
Green/Red
Connector
Catalog
Number
Options
Required Power Rear/Top Rear/Bottom
Supply
(DTE)
(DCE)
LEDs Alarms
Components Included
Quantity/Type
Patch Module
Quantity/Type Blank
Other Module Modules Chassis
12/02
•
517
Data Management and Access Products
• Dimensions (H x W x D): 5.25 x 19 x 9 inches (13.3 x 48.26 x 22.9 cm)
EIA-530
PMS-614001
PMS-614007
PMS-616004
PMS-616004RED
PMS-616005
PMS-616005RED
DMPS-5A
DMPS-5A
None
None
None
None
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
P (DB25)
P (DB25)
P (DB25)
P (DB25)
R (DB25)
R (DB25)
Yes
Yes
No
No
No
No
No
No
No
No
No
No
1 PMM-636003
16 PMM-614001
None
16 PMM-614001
None
16 PMM-614004
None
16 PMM-614004RED
1 PMM-636003
16 PMM-614005
16 PMM-616005RED 1 PMM-636-001
1
2
2
2
1
1
PMCH-1
PMCH-1
PMCH-2
PMCH-2
PMCH-2
PMCH-2
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
10
EIA-530 PatchMate™
Assemblies
Data Management and Access Products
Patching with LEDs and Test Module
• Provides 16 lines of LED patching with
PMM-614001 modules
• A non-LED test module (PMM-636003) is provided
in the 18th slot of the chassis
• Power supply DMPS-5A is required
PMS-614001 (R/P)
Patching with LEDs
• Provides 16 lines of LED patching with
PMM-614001 modules
• Power supply DMPS-5A is required
PMS-614007 (R/P)
Patching without LEDs and with
Test Module
• Provides 16 lines of non-LED patching with
PMM-616004 modules
• A non-LED test module (PMM-636003) is provided
in the 18th slot of the chassis
PMS-616005 (R/R)
• No power supply is required
• Offered in Red (PMS-616005RED)
Patching without LEDs
•
517
• Provides 16 lines of non-LED patching
with PMM-616004 modules
• No power supply is required
• Also available in Red (PMS-616004RED)
12/02
PMS-616004 (R/P)
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
11
EIA-530 PatchMate™
12/02
•
517
Data Management and Access Products
Modules
•
•
•
•
•
•
•
•
•
•
Dimensions (H x W x D): 5.25 x 0.95 x 5.5 inches (13.3 x 2.41 x 13.97 cm)
Weight: 8 oz. (224 g)
Provides patch cord access to terminated EIA-530 data circuits
Patches 25 leads
Data rate of DC to 5 Mbps (LED modules) to 20 Mbps (non-LED modules)
DB25 connector interface
Key Type A
Patch cord (PMP-6XX007) available in 2-10 foot lengths
Balanced or unbalanced operation available at user discretion
Modules and patch cords are grey
Modules with LEDs
• Front panel mounted tri-color LEDs provide passive monitoring of the circuit leads terminated to the
patch module (see LED chart)
• Green LEDs represent an asserted signal on the lead
• Red LEDs represent a non-asserted signal on the lead
• Clear LEDs represent a disconnected/inadequate signal on the lead
EIA -530 LED Chart
Pin A
2
3
4
5
6
8
15
17
20
24
Pin B
14
16
19
13
22
10
12
9
23
11
Abbreviation
TD
RD
RS
CS
RR
DM
TT
RT
TR
TT
Description
Transmitted Data
Received Data
Request to Send
Clear to Send
DCE Ready
Received Line Signal Detector
Transmit Signal Element Timing (DCE)
Receive Signal Element Timing
DTE Ready
Transmit Signal Element Timing (DTE)
Connector
Catalog
Number
Module
Type
Rear/Top
(DTE)
Rear/Bottom
(DCE)
EIA-530
PMM-614001
PMM-616001
PMM-616001(Black)
PMM-616004
PMM-616004RED
PMM-616005
PMM-636001
PMM-636002
PMM-636003
PMM-636003RED
PMME-5
PMBP-530-2
PMBP-530-1
Patch
Patch
Patch
Patch
Patch
Patch
Patch
Patch
Test
Test
Patch
Interface
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R(DB25)
P (DB25)
R (DB25)
P (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
R (DB25)
Options
Recommended Products
LEDs
Alarms
•
•
•
R (DB25)
•
LEDs
Green/Red
Green/Red
Green/Red
Green/Red
Green/Red
Green/Red
Green/Red
Green/Red
Green/Red
Green/Red
Chassis
Patch
Cords
PMCH-1
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX007
PMP-6XX001
PMP-6XX007
P = Plug/Male Connector
R = Receptacle/Female Connector
XX = Length of patch cord
*External power supply DMPS-11 or DMPS-11E is required when used in unpowered chassis PMCH-2
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
12
EIA-530 PatchMate™
Modules
Data Management and Access Products
Patch Module with LEDs
INDICATORS
MONITOR
CIRCUITS
COMPUTER
MODEM
• Contains three front panel ports
for easy passive or intrusive easy
access to the data circuit
COMPUTER
(DTE)
MODEM
(DCE)
MONITOR
• Use with chassis PMCH-1
PMM-614001 (R/P)
Patch Module without LEDs
• Contains three front panel ports
for easy passive or intrusive access
to the data circuit
COMPUTER
(DTE)
COMPUTER
MODEM
MODEM
(DCE)
MONITOR
• Rear/bottom DCE plugs available
• Use with chassis PMCH-1 or
PMCH-2
• No power supply is required
PMM-616004 (P/R)
PMM-616005 (R/R)
PMM-616004RED
PMM-616001
Test Module without LEDs
TEST
EQUIP-1
FRONT
PANEL
ACCESS-1
TEST
EQUIP-2
517
FRONT
PANEL
ACCESS-2
• Provides the interface terminations
between the appropriate test
equipment and the selected
system patch module
• Contains front and rear connectors
for attachment of diagnostic
equipment to patch jack
INTERFACE
MODULE
• Use with chassis PMCH-1 or
PMCH-2
•
12/02
• Provided with Berg mini-jumpers
to select balanced or unbalanced
operation for each monitored
“A” input lead
PMM-636003 (R)
PMM-636003RED
PMM-636001 (R)
• No power supply is required
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
13
EIA-530 PatchMate™
Modules
Data Management and Access Products
Breakout Module with LEDs and without Alarms
• Available for connecting, disconnecting, cross-connecting, accessing,
patching, monitoring or signal insertion on individual circuits within
the EIA-530 multicircuit interface
• Contains ten tri-state LED indicators for signal interface monitoring
• Monitoring of EIA-530 balanced and unbalanced interfaces is user
selectable
• Provides user option for monitoring of the transmit signal element
timing (TT) for either DCE or DTE sourced
• Pulse trap circuit and a test LED can be jumpered to any lead via the
pin jack
PMBP-530-2 (R)
• Provides balanced and unbalanced test voltages for signal injection
• 24 break-off switches
• 48 pin jacks (24 each for DTE/DCE)
INDICATORS
MONITOR
CIRCUITS
TEST
CIRCUITS
• A pin jack patch cord kit is included
FRONT ACCESS
PANEL DTE
TEST
EQUIP
FRONT ACCESS
PANEL DCE
• Uses two slots in chassis PMCH-1 or PMCH-2
BREAKOUT
MODULE
• External power supply DMPS-11 or DMPS-11E is required when used
with unpowered PMCH-2 chassis
Breakout Module without LEDs
• Available for connecting, disconnecting, cross-connecting, accessing,
patching, monitoring or signal insertion on individual circuits within
the EIA-530 multicircuit interface
• Balanced and unbalanced operation
• 24 break-off switches
• 48 pin jacks (24 each for DTE/DCE)
• A pin jack patch cord kit is provided
• Provides one patch jack for DTE connection and one for DCE
connection
PMBP-530-1 (R)
• Uses two slots in chassis PMCH-1 or PMCH-2
517
•
12/02
• Provides one patch jack for DTE connection and one for DCE
connection
• No power supply is required
FRONTACCESS
PANEL DTE
TEST
EQUIP
FRONT ACCESS
PANEL DCE
BREAKOUT
MODULE
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
14
EIA-530 PatchMate™
Chassis
12/02
•
517
Data Management and Access Products
Powered Chassis
For PatchMate Modules Requiring Power,
LEDs and Alarming
• Designed to provide power to modules with
LEDs and alarms
• May also be used with unpowered modules
• Mounts up to 18 modules
PMCH-1
• Chassis PMCH-1 is labeled to correspond with
all EIA-530, EIA-232 and V.35 PatchMate
Modules
• Requires power supply DMPS-5A
Unpowered Chassis
For Unpowered PatchMate Modules
• Designed to be used with modules that do not
require power
• Mounts up to 18 modules
• Chassis PMCH-2 is labeled to correspond with all
EIA-530, EIA-232 and V.35 PatchMate Modules
PMCH-2
• LED breakout and test modules require the use
of power supply DMPS-11 or DMPS-11E when
used in chassis PMCH-2
Module
Catalog Number
PMCH-1
(Powered)
PMCH-2
(Unpowered)
EIA-530
PMBP-530-2
PMBP-530-1
PMM-614001
PMM-616001
PMM-616004
PMM-616004RED
PMM-616005
PMM-616005RED
PMM-636003
PMME-5
R
C
R
C
C
C
C
C
C
N
C
R
N
R
R
R
R
R
R
R
R = Recommended
w w w. a d c . c o m
C = Compatible
•
N = Not Compatible
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
15
EIA-530 PatchMate™
Patch Cords
12/02
•
517
Data Management and Access Products
P= Plug/Male Connector
R= Receptacle/Female Connector
Patch Cords
Catalog Number
Cord Type
PMP-602007
PMP-602900
PMP-603007
PMP-604007
PMP-606007
PMP-610007
PMP-616007
PMP-61R507
PMP-602005
PMP-604010
PMP-610006
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate (null modem)
EIA-530 PatchMate (null modem)
EIA-530 PatchMate (null modem)
Length (in feet) Balanced
• Key Type A
• Plug and cord are grey
• Balanced
• Key Type B
Catalog Number
• Balanced
PMP-602007RED
PMP-604007RED
PMP-606007RED
PMP-608007RED
PMP-610007RED
PMPC-5B-10
PMPC-5B-2
PMPC-5B-3
PMPC-5B-4
PMPC-5B-8
Conversion Cords
• Converts EIA-530
PatchMate Key Type A
connector to an EIA-530
Key Type B DB25 plug or
receptacle connector.
• Converts EIA-530
PatchMate Key
Type A plug to a
PatchMate EIA-232
Key Type B plug.
• Looping cord Key Type B
w w w. a d c . c o m
•
Cord Type
Length (in feet)
Color
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
EIA-530 PatchMate
02
04
06
08
10
10
02
03
04
08
Red
Red
Red
Red
Red
Grey
Grey
Grey
Grey
Grey
Catalog Number
Cord Type
Length (in feet)
PMP-606009
PMP-606009RED
PMP-610009
PMP-606010
PMP-610010
PMP-602009
PMP-603009
PMP-603010
PMP-604009
PMP-604010
PMP-608009
PMP-608010
Conversion (P)
Conversion (P)
Conversion (P)
Conversion (R)
Conversion (R)
Conversion (P)
Conversion (P)
Conversion (R)
Conversion (P)
Conversion (R)
Conversion (P)
Conversion (R)
06
06
10
06
10
02
03
03
04
04
08
08
Catalog Number
Cord Type
Length (in feet)
PMP-603008
PMP-604008
PMP-606008
PMP-608008
PMP-610008
Conversion
Conversion
Conversion
Conversion
Conversion
03
04
06
08
10
Catalog Number
Cord Type
Length (in feet)
PMP-603006
PMP-610006
Looping
Looping
03
10
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
02
02
03
04
06
10
16
1.5
02
04
10
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
16
EIA-232/V.24 has been a long standing electrical and mechanical data communication interface standard.
EIA-232/V.24 defines the narrowband, serial binary data communications channel used between leased or
dial-up modems, multiplexers or other communications devices for data transport and data computing or
terminal equipment. ADC's EIA-232/V.24 PatchMate products are designed and tested to fully support all
25 unbalanced electrical signals for data, timing and control, that operate at speeds up to 19.2 Kbps.
EIA-232/V.24 Summary
• Patches 25 leads
• Data rate of DC up to 19.2 Kbps
• DB25 connector interface
• Key Type B
• Unbalanced patch cord (PMPC-X) available in 2-10 foot lengths
• Modules and patch cords are black
EIA-232/V.24 Pin Chart
1
14
15
16
17
18
19
20
21
22
23
24
25
2
3
4
5
Pin
Abbreviation
Description
1
FG
Frame Ground
2
TD
Transmit Data
Green
3
RD
Receive Data
Green
4
RS
Request To Send
Red
5
CS
Clear To Send
Red
6
DSR
Data Set Ready
Red
7
SG
Signal Ground
8
DCD
Data Carrier Detect
LEDs
6
7
8
9
10
9
Positive DC Test Voltage
10
Negative DC Test Voltage
11
Unassigned
Green
11
12
SCD
Secondary Received Line Detector
13
SCS
Secondary Clear To Send
14
STD
Secondary Transmitted Data
15
TC
Transmitter Clock
16
SRD
Secondary Receive Data
17
RC
Receive Clock
18
LL
Local Loopback
19
SRS
Secondary Request To Send
20
DTR
Data Terminal Ready
Red
21
SQ
Signal Quality Detect
Green
22
RI
Ring Indicator
23
CH
Data Signal Rate Selector
24
ETC
External Transmitter Clock
25
TM
Test Mode
12/02
12
517
13
•
Data Management and Access Products
EIA-232/V.24 PatchMate™
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
17
EIA-232/V.24 PatchMate™
Assemblies
EIA-232/V.24 LED Chart
• Weight: 13 lbs (6 kg)
Pin A
Abbreviation
LEDs
• Assemblies with LEDs have 8 indicators on each
patching module
2
TD
Green
3
RD
Green
• Assemblies with alarms have an additional
amber alarm LED indicator
4
RS
Red
5
CS
Red
6
DSR
Red
8
DCD
Green
20
DTR
Red
21
SQ
Green
• Patches 25 leads
• Data rate of DC up to 19.2 Kbps
• DB25 connector interface
• Key Type B
• Unbalanced patch cord (PMPC-X) available in
2-10 foot lengths
• Modules and patch cords are black
Connector
Options
Components Included
Catalog
Number
Rear/Top Rear/Bottom
(DTE)
(DCE)
LEDs Alarms
QTY/Type
Patch Module
EIA-232/V.24
PMSLA-16
PMSLA-16-MF
PMSLA-16(R)
PMSL-16
PMSL-16-MF
PMS-16
PMS-16-MF
(R) DB25
(R) DB25
(R) DB25
(R) DB25
(R) DB25
(R) DB25
(R) DB25
16 PMMLA-1
16 PMMLA-2
16 PMMLA-1
16 PMML-1
16 PMML-2
16 PMM-1
16 PMM-2
(R) DB25
(P) DB25
(R) DB25
(R) DB25
(P) DB25
(R) DB25
(P) DB25
•
•
•
•
•
•
•
•
Blank
Modules
2
2
2
2
2
2
2
Chassis
PMCH-1
PMCH-1
PMCH-1
PMCH-1
PMCH-1
PMCH-2
PMCH-2
Required
Power Supply
DMPS-5
5E, or 548
None
None
P = Plug/Male Connector
R = Receptacle/Female Connector
12/02
•
517
Data Management and Access Products
• Dimensions (H x W x D): 5.25 x 19 x 9 inches
(13.3 x 48.26 x 22.9 cm)
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
18
EIA-232/V.24 PatchMate™
Assemblies
• Provides 16 lines of LED and alarm patching
with PMMLA-1 (R/R) or PMMLA-2 (P/R)
modules
• Each module has a selectable visual and audible
alarm that can be chosen to indicate the
absence or continued presence of any of the
monitored signals
• The user can disable the alarm completely, have
just an LED alarm, or have an alarm with the
LED and audible buzzer
PMSLA-16 (R/R)
PMSLA-16-MF (P/R)
PMSLA-16 (G)/(R)
PMSLA-16(G)/(R)
• The alarm is set if the signal has been off/on for
a period of 50 µ seconds to 68 seconds
• Alarm delay is chosen on front panel for each
module in eight discrete steps
• The user can reset the alarm by touching two
contacts on the front of the module
• Power supply DMPS-5, DMPS-5E, or DMPS-548
is required
Patching with LEDs and
without Alarms
• Provides 16 lines of LED patching with PMML-1
(R/R) or PMML-2 (P/R) modules
• Power supply DMPS-5, DMPS-5E, or DMPS-548
is required
PMSL-16 (R/R)
PMSL-16-MF (P/R)
Patching without LEDs or Alarms
• Provides 16 lines of non-LED and non-alarm
patching with PMM-1 (R/R) or PMM-2
(P/R) modules
• No power supply is required
•
517
Data Management and Access Products
Patching with LEDs and Alarms
12/02
PMS-16 (R/R)
PMS-16-MF (P/R)
G= Grey Colored Modules
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
19
EIA-232/V.24 PatchMate™
Modules
EIA-232/V.24 LED Chart
Data Management and Access Products
• Dimensions (H x W x D): 5.25 x 19 x 9 inches
(13.3 x 48.26 x 22.9 cm)
• Weight: 13 lbs (6 kg)
Pin A
Abbreviation
LEDs
• Assemblies with LEDs have 8 indicators on each
patching module
2
TD
Green
3
RD
Green
• Assemblies with alarms have an additional
amber alarm LED indicator
4
RS
Red
5
CS
Red
6
DSR
Red
8
DCD
Green
20
DTR
Red
21
SQ
Green
• Patches 25 leads
• Data rate of DC up to 19.2 Kbps
• DB25 connector interface
• Key Type B
• Unbalanced patch cord (PMPC-X) available in
2-10 foot lengths
• Modules and patch cords are black
Connector
Catalog
Number
Module
Type
Rear/Top
(DTE)
EIA-232/V.24
PMMLA-1
PMMLA-2
PMML-1
PMML-2
PMM-1
PMM-2
PMM-2 (R)
PIMMLA-1
PMME-1
PIMMLA-2
PMME-2
PMBP-2
PMBP-1
Patch
Patch
Patch
Patch
Patch
Patch
Patch-Red
Interface
Interface
Test
Test
Breakout
Breakout
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
DB25
DB25
DB25
DB25
DB25
DB25
DB25
DB25
DB25
DB25
DB25
Options
Rear/Bottom
(DCE)
(R)
(P)
(R)
(P)
(R)
(P)
(P)
(R)
(R)
Recommended Products
LEDs
Alarms
Chassis
Patch
Cords
•
•
•
•
•
•
•
•
•
•
PMCH-1
PMCH-1
PMCH-1
PMCH-1
PMCH-1 or 2
PMCH-1 or 2
PMCH-1 or 2
PMCH-1
PMCH-1 or 2
PMCH-1 or 2*
PMCH-1 or 2
PMCH-1 or 2*
PMCH-1 or 2
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
PMPC-X
DB25
DB25
DB25
DB25
DB25
DB25
DB25
DB25
DB25
•
P = Plug/Male Connector
R = Receptacle/Female Connector
12/02
•
517
*External power supply DMPS-11 or DMPS-11E is required when used in unpowered chassis PMCH-2.
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
20
EIA-232/V.24 PatchMate™
Modules
• Alarming is on with absence or continued presence of an
electrical signal
• Alarm indicated by an amber LED and/or an audible output
• A front panel selection switch allows choice of alarm off, audible
and visual alarm, or visual alarm only
• An eight-position rotary switch allows discrete selection of alarm
delay between 50 µ seconds and 68 seconds (Alarm delays will
differ slightly in countries with 50 Hz power)
• Alarming on any monitored signal is user-selectable by simply
moving a strap on the module
PMMLA-1 (R/R)
PMMLA-2 (P/R)
INDICATORS
MONITOR
CIRCUITS
• Use with chassis PMCH-1
COMPUTER
(DTE)
COMPUTER
MODEM
MODEM
(DCE)
MONITOR
Patch Module with LEDs and without Alarms
INDICATORS
MONITOR
CIRCUITS
COMPUTER
(DTE)
COMPUTER
MODEM
• Use with chassis PMCH-1
MODEM
(DCE)
MONITOR
PMML-1 (R/R)
PMML-2 (P/R)
Patch Module without LEDs or Alarms
517
Data Management and Access Products
Patch Module with LEDs and Alarms
COMPUTER
COMPUTER
(DTE)
•
MODEM
MODEM
(DCE)
• No power supply is required
12/02
MONITOR
• Use with chassis PMCH-1 or
PMCH-2
PMM-1 (R/R)
PMM-2 (P/R)
w w w. a d c . c o m
P= Plug/Male Connector
R= Receptacle/Female Connector
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
21
EIA-232/V.24 PatchMate™
Modules
• Provides two front panel PatchMate jacks and two rear connectors
• Allows test equipment or spare ports to be terminated within
the chassis
• LED monitoring and alarming circuitry are associated with the
bottom monitor port
• Alarm is activated with absence or continued presence of an
electrical signal
• Alarm indicated by an amber LED and/or audible alarm located
locally in the chassis or remotely
• A front panel selection switch allows choice of alarm “Off”,
“Audible and Visual Alarm” or “Visual Alarm Only”
PIMMLA-1 (R)
FRONT
PANEL
ACCESS-1
MONITOR
CIRCUITS
• An eight position front panel rotary switch allows discrete selection
of alarm delay between 50 µ seconds and 68 seconds (Alarm times
will differ slightly in countries with 50 Hz power)
TEST
EQUIP-1
TEST
EQUIP-2
FRONT
PANEL
ACCESS-2
• Use with chassis PMCH-1
INTERFACE
MODULE
Interface Module without LEDs or Alarms
FRONT
PANEL
ACCESS-1
FRONT
PANEL
ACCESS-2
• Provides two front pane
PatchMate jacks and two rear
connectors
• Allows test or spare equipment to
be terminated within the chassis
• Use with PMCH-1 or PMCH-2
• No power supply is required
INTERFACE
MODULE
PMME-1 (R)
Test Module with LEDs and
Alarms
•
INDICATORS
TEST
EQUIPMENT
CONNECTOR (P)
PATCHMATE
PORT
TEST MODULE
Provides LED monitoring and an
adjustable alarm on the circuit
• Brings EIA-232/V.24 signal leads to
DB25 receptacle and PatchMate
patch jack
MONITOR
CIRCUITS
RS232/V24
CONNECTOR (R)
•
12/02
TEST
EQUIP-1
TEST
EQUIP-2
517
Data Management and Access Products
Interface Module with LEDs and Alarms
DMPS-11
POWER
SUPPLY
(OPTIONAL)
• Use with chassis PMCH-1 or
PMCH-2
• External power supply DMPS-11 or
DMPS-11E is required when used
in unpowered chassis PMCH-2
PIMMLA-2 (R)
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
22
EIA-232/V.24 PatchMate™
Modules
• Brings EIA-232/V.24 signal leads to
DB25 receptacle and PatchMate
patch jack
FRONT PANEL
DB25
CONNECTOR (R)
• Use with chassis PMCH-1 or
PMCH-2
• No power supply is required
PMME-2 (R)
Breakout Module with LEDs and without Alarms
• Available for connecting, disconnecting,cross-connecting,
accessing, patching, monitoring or signal insertion on individual
circuits within the EIA-232/V.24 multicircuit interface
• Contains nine LED indicators for signal interface monitoring
• Unbalanced test sources
• Pulse trap circuit and test LED can be jumpered from any lead via
the pin jacks
• 24 break-off switches
• 48 pin jacks (24 each for DTE/DCE)
PMBP-2
INDICATORS
• Pin jack jumper kit included
• Uses two slots in chassis PMCH-1 or PMCH-2
MONITOR
CIRCUITS
TEST
CIRCUITS
FRONT ACCESS
PANEL DTE
• External power supply DMPS-11 or DMPS-11E is required when
used in unpowered chassis PMCH-2
TEST
EQUIP
FRONT ACCESS
PANEL DCE
BREAKOUT
MODULE
• Available for connecting,
disconnecting, cross-connecting,
accessing, patching, monitoring or
signal insertion on individual circuits
within multicircuit interfaces
Breakout Module without LEDs
• Balanced and unbalanced operation
FRONTACCESS
PANEL DTE
TEST
EQUIP
FRONT ACCESS
PANEL DCE
•
12/02
TEST
EQUIPMENT (R)
FRONT PANEL
PATCH ACCESS
517
Data Management and Access Products
Test Module without LEDs and Alarms
• 24 break-off switches
• 48 pin jacks (24 each for DTE/DCE)
BREAKOUT
MODULE
• Provides one patch jack for DTE
connection and one for DCE
connection
• Pin jack jumper kit included
PMBP-1
• Uses two slots in chassis PMCH-1 or
PMCH-2
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
• No power supply is required
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
23
EIA-232/V.24 PatchMate™
Chassis
12/02
•
517
Data Management and Access Products
Powered Chassis
For PatchMate Modules Requiring Power,
LEDs and Alarming
• Designed to provide power to modules with
LEDs and alarms
• May also be used with unpowered modules
• Mounts up to 18 modules
PMCH-1
• Chassis PMCH-1 is labeled to correspond with
all EIA-530, EIA-232 and V.35 modules
• Requires power supply DMPS-5, DMPS-5E or
DMPS-548
Unpowered Chassis
For Unpowered PatchMate Modules
• Designed to be used with modules that do not
require power
• Mounts up to 18 modules
• Chassis PMCH-2 is labeled to correspond with
all EIA-530, EIA-232 and V.35 modules
PMCH-2
• LED breakout and test modules require the use
of power supply DMPS-11 or DMPS-11E when
used in chassis PMCH-2
Module
Catalog Number
EIA-232/V.24
PMMLA-1
PMMLA-2
PMML-1
PMML-2
PMM-1
PMM-2
PMM-2 (R)
PIMMLA-1
PIMMLA-2
PMME-1
PMME-2
PMBP-2
PMBP-1
R = Recommended
w w w. a d c . c o m
PMCH-1
(Powered)
PMCH-2
(Unpowered)
R
R
R
R
C
C
C
R
R
C
C
R
C
N
N
N
N
R
R
R
N
C
R
R
C
R
C = Compatible
•
N = Not Compatible
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
24
EIA-232/V.24 PatchMate™
Patch Cords
12/02
•
517
Data Management and Access Products
EIA-232/V.24 Patch Cords
• Unbalanced, key type B
Catalog Number
• Plug is black, cord is grey
PMPC-1R5
PMPC-2
PMPC-3
PMPC-4
PMPC-6
PMPC-8
PMPC-10
PMPC-12
PMPC-15
PMPC-30
PMPC-200
Length (in feet)
Cord Type
1.5
2
3
4
6
8
10
12
15
30
200
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232 PatchMate
EIA-232/V.24 Conversion Patch Cords
• Converts PatchMate
Key Type B plug to
EIA-232 connector
Catalog Number
PMCPC-M-6
PMCPC-M-10
PMCPC-F-6
PMCPC-F-10
PMPC-F9-10
Cord Type
Length (in feet)
Conversion (P) DB25 plug or receptacle
Conversion (P) DB25 plug or receptacle
Conversion (R) DB25 plug or receptacle
Conversion (R) DB25 plug or receptacle
Conversion (Female) 9-pin
6
10
6
10
10
EIA-232/V.24 Modem Eliminator Patch Cords
• Permits back to back connection of
two EIA-232 DTE or DCE interfaces
2
2
3
3
4
4
5
5
6
6
8
8
12
12
17
17
19
19
20
20
24
24
Catalog Number
PM-MM-PC-2
PM-MM-PC-3
PM-MM-PC-4
PM-MM-PC-6
PM-MM-PC-8
PM-MM-PC-10
Cord Type
Length (in feet)
Modem Eliminator
Modem Eliminator
Modem Eliminator
Modem Eliminator
Modem Eliminator
Modem Eliminator
2
3
4
6
8
10
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
25
The V.35 standard has grown in popularity
throughout the industry because of its ability to
support high speed narrowband, serial binary data
communications applications. Most suppliers of
LAN routers, T1 multiplexers, inverse multiplexers,
video conferencing systems, channel service units
(CSUs), data service units (DSUs) and other high
speed data computing or terminal equipment offer
the V.35 interface as a standard for wide area
networking (WAN) applications. ADC's V.35
PatchMate products are designed and tested to fully
support up to 25 conductors of the V.35 balanced
data and timing signals and unbalanced control
signals operating at speeds up to 2.0 Mbps.
V.35 Summary
• Patches up to 25 leads
• Data rate of DC to 2 Mbps.
• V.35 connector interface
• Key Type B
• Balanced patch cord (PMPC-BV-X) available in
2-10 foot lengths
• Modules and patch cords are grey
V.35 Pin Chart
B
D
F
J
L
R
T
Y
X
E
Abbreviation
Description
A
FG
Frame Ground
B
SG
Signal Ground
C
RTS
Request to Send
Green
D
CTS
Clear to Send
Green
E
DSR
Data Set Ready
F
DCD
Data CXR Detect
Red
Red
LEDs
H
DTR
Data Terminal Ready
C
J
RI
Ring Indicator
H
K
Unassigned
L
Unassigned
M
Unassigned
N
Unassigned
P
TD
Transmitted Data (+)
Green
R
RD
Received Data (+)
Green
S
TD
Transmitted Data (-)
T
RD
Received Data (-)
517
K
P
S
U
W
V
AA
U
ETC
Transmitter Clock Ext (+)
V
RC
Received Clock (+)
W
ETC
Transmitter Clock Ext (-)
•
BB
A
Pin
X
RC
Received Clock (-)
12/02
Data Management and Access Products
V.35 PatchMate™
Y
TC
Transmitter Clock (+)
Z
AA
w w w. a d c . c o m
•
Red
Unassigned
TC
BB
MM
Red
Transmitter Clock (-)
Unassigned
BO
Busy Signal
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
26
V.35 PatchMate™
Assemblies
12/02
•
517
Data Management and Access Products
•
Assemblies patch 16 lines and have 2 blank
modules
V.35 LED Chart
• Assemblies with LEDs have 8 monitoring
indicators on each patching module
Pin A
Pin B
Abbreviation
LEDs
• One alarm indicator LED is provided on
LED modules
P
S
TD
Green
R
T
RD
Green
• Dimensions (H x W x D):
5.25 x 19 x 12.5 inches
(13.3 x 48.26 x 31.7 cm)
C
RTS
Green
D
CTS
Green
F
DCD
Red
• Weight: 21-22 lbs (9-10 kg)
Y
AA
TC
Red
• Patches 25 leads
V
X
RC
Red
• Data rate of DC to 2 Mbps.
H
DTR
Red
• V.35 connector interface
• Key Type B
• Balanced patch cord (PMPC-BV-X) available in
2-10 foot lengths
• Modules and patch cords are grey
Connector
Options
Catalog
Number
Rear/Top Rear/Bottom
(DTE)
(DCE)
LEDs Alarms
V.35
PMSLA-16-V35FF
PMSLA-16-V35
PMS-16-V35FF
PMS-16-V35
(R)
(R)
(R)
(R)
V.35
V.35
V.35
V.35
(R)
(P)
(R)
(P)
V.35
V.35
V.35
V.35
•
•
•
•
Components Included
QTY/Type
Patch Module
16 PMMLA-V35FF
16 PMMLA-V35
16 PMM-V35FF
16 PMM-V35
Blank
Modules
2
2
2
2
Chassis
Required
Power Supply
PMCH-1
PMCH-1
PMCH-2
PMCH-2
DMPS-5
5E, or 548
None
None
P = Plug/Male Connector
R = Receptacle/Female Connector
Patching with LEDs and Alarms
• Provides 16 lines of LED/alarm patching utilizing
PMMLA-V.35 modules
• Alarm is selectable on one of eight leads and
can be activated by either a positive or
negative transition
PMSLA-16-V35FF (R/R)
PMSLA-16-V35 (R/P)
• Power supply DMPS-5, DMPS-5E or
DMPS-548 is required
Patching without LEDs or Alarms
• Provides 16 lines of non-LED patching utilizing
PMM-V.35 modules
• No power supply is required
PMS-16-V35FF (R/R)
PMS-16-V35 (R/P)
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
27
V.35 PatchMate™
Modules
12/02
•
517
Data Management and Access Products
• Modules with LEDs have 8 monitoring indicators
V.35 LED Chart
• One amber alarm indicator LED is provided on
LED modules
Pin A
Pin B
Abbreviation
LEDs
• Dimensions (H x W x D): 5.25 x 0.95 x 9.6 inches
(13.3 x 2.41 x 24.5 cm)
• Weight: 9 oz. (252 g)
P
S
TD
Green
R
T
RD
Green
• Requires cable support bar BKT-V35
C
RTS
Green
• Includes a sub-board which installs easily onto
any PatchMate chassis to allow removal of the
patch module without removing the attached
cables and provides strapping options to select
patching of additional leads
D
CTS
Green
F
DCD
Red
• Pin A (frame ground) can be left routed from the
DTE to the DCE connector or through the patch
mechanism
H
Y
AA
TC
Red
V
X
RC
Red
DTR
Red
• The standard 19 leads routed through the patch
mechanism and any 6 of the remaining 15 leads
can be user selected by the insertion of hardwire
straps to give the user full patch access to 25 of the 34 leads
• Patches up to 25 leads
• Data rate of DC to 2 Mbps
• V.35 connector interface
• Key Type B
• Balanced patch cord (PMPC-BV-X) available in 2-10 foot lengths
Connector
Catalog
Number
Module
Type
Rear/Top
(DTE)
V.35
PMMLA-V35FF
PMMLA-V35
PMM-V35FF
PMM-V35
PIMMLA-V35
PMME-V35
Patch
Patch
Patch
Patch
Interface
Interface
(R)
(R)
(R)
(R)
(R)
(R)
V.35
V.35
V.35
V.35
V.35
V.35
Options
Rear/Bottom
(DCE)
(R)
(P)
(R)
(P)
(R)
(R)
Recommended Products
LEDs
Alarms
Chassis
•
•
•
•
•
•
PMCH-1
PMCH-1
PMCH-1 or 2
PMCH-1 or 2
PMCH-1
PMCH-1 or 2
V.35
V.35
V.35
V.35
V.35
V.35
Patch
Cords
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
PMPC-BV-X
P = Plug/Male Connector
R = Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
28
V.35 PatchMate™
Modules
• Real time status LEDs
• Provides user selectable alarm which is activated by either a positive
or negative transition on any one of the eight leads
• Alarm circuitry is optioned by straps on the module
• A front panel selection switch allows for a choice of visual alarms
only, visual and audible alarm, or alarm "OFF"
• Alarming is indicated audibly on the chassis and/or visually by an
amber LED located on the module
• A separate front panel eight position rotary switch allows discrete
selection of alarm delay between 50 µ seconds and 68 seconds.
(Alarm delay will vary slightly in countries with 50 Hz power.)
PMMLA-V35FF (R/R)
PMMLA-V35 (R/P)
• By using straps, the clock source (TC) can be user selected from
either the DTE or DCE device
INDICATORS
MONITOR
CIRCUITS
COMPUTER
(DTE)
COMPUTER
MODEM
• Use with chassis PMCH-1
MODEM
(DCE)
MONITOR
Patch Module without LEDs or Alarms
COMPUTER
COMPUTER
(DTE)
• Provides patch access for V.35
interface
MODEM
(DCE)
• Use with chassis PMCH-1 or
PMCH-2
MODEM
MONITOR
• No power supply is required
PMM-V35FF (R/R)
PMM-V35 (R/P)
12/02
•
517
Data Management and Access Products
Patch Module with LEDs and Alarms
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
29
V.35 PatchMate™
Modules
• Used to provide jack access to a data line monitor, analyzer, or
spare ports
• Real time status indicated with LEDs
• Provides user selectable alarm which is activated by either a positive
or negative transition on any one of the eight leads
• Alarm circuitry is optioned by straps on the module
• A front selection switch allows for a choice of visual alarm only,
visual and audible alarm, or alarm "OFF"
• Alarming is indicated audibly on the chassis and/or visually by an
amber LED located on the module
PIMMLA-V35 (R/R)
• A separate front panel eight position rotary switch allows discrete
selection of alarm delay between 50 µ seconds and 68 seconds
FRONT
PANEL
ACCESS-1
MONITOR
CIRCUITS
TEST
EQUIP-1
TEST
EQUIP-2
FRONT
PANEL
ACCESS-2
• By using straps, the clock source (TC) can be user selected from
either the DTE or DCE device
• Use with chassis PMCH-1
INTERFACE
MODULE
Interface Module without LEDs or Alarms
TEST
EQUIP-1
FRONT
PANEL
ACCESS-1
TEST
EQUIP-2
FRONT
PANEL
ACCESS-2
• Can be used as a test access port
to access a data line monitor, as a
trunking module, or to access
spare ports
• Use with chassis PMCH-1 or
PMCH-2
INTERFACE
MODULE
• No power supply is required
PMME-V35 (R/R)
Subboard Assembly
• PMO-513001: Subboard
Female/Female Assembly
12/02
•
517
Data Management and Access Products
Interface Module with LEDs and Alarms
• PMO-516001: Subboard
Female/Male Assembly
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
30
V.35 PatchMate™
Chassis
12/02
•
517
Data Management and Access Products
Powered Chassis
For PatchMate Modules Requiring Power,
LEDs and Alarming
• Designed to provide power to modules with
LEDs and alarms
• Mounts up to 17 V.35 modules in positions 1
through 17
PMCH-1
• Requires accessory BKT-V35 (cable support bar)
• May also be used with unpowered modules
• Chassis PMCH-1 is labeled to correspond with
all EIA-530, EIA-232 and V.35 PatchMate
modules
• Requires power supply DMPS-5, DMPS-5E or
DMPS-548
Unpowered Chassis
For Unpowered PatchMate Modules
• Designed to be used with modules that do not
require power
• Mounts up to 17 V.35 modules in positions 1
through 17
• Requires accessory BKT-V35 (cable support bar)
PMCH-2
• Chassis PMCH-2 is labeled to correspond with
all EIA-530, EIA-232 and V.35 PatchMate
modules
Module
Catalog Number
V.35
PMMLA-V35FF
PMMLA-V35
PMM-V35FF
PMM-V35
PIMMLA-V35
PMME-V35
R = Recommended
w w w. a d c . c o m
PMCH-1
(Powered)
PMCH-2
(Unpowered)
R
R
C
C
R
C
N
N
R
R
N
R
C = Compatible
•
N = Not Compatible
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
31
V.35 PatchMate™
Patch Cords
• Balanced, Key Type B
Catalog Number
PMPC-BV-2
PMPC-BV-3
PMPC-BV-4
PMPC-BV-6
PMPC-BV-8
PMPC-BV-10
PMPC-BV-20
PMPC-BV-35
PMPC-BV-50
PMPC-BV-75
PMPC-BV-100
PMPC-BV-200
Cord Type
Length (in feet)
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
V.35 PatchMate
2
3
4
6
8
10
20
35
50
75
100
200
Cord Type
Length (in feet)
Conversion (P)
Conversion (P)
Conversion (P)
Conversion (R)
Conversion (R)
Conversion (R)
6
10
20
45
6
10
V.35 Conversion Patch Cords
• Converts PatchMate plug or
receptacle to V.35 plug or receptacle
connector
Catalog Number
PMCPC-MV-6
PMCPC-MV-10
PMCPC-MV-20
PMCPC-MV-45
PMCPC-FV-6
PMCPC-FV-10
V.35 Subboard- Patch Cord
Assembly
Catalog Number
PM0-513001
PM0-516001
Connector Type
Female/Female
Male/Female
12/02
•
517
Data Management and Access Products
V.35 Patch Cords
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
32
EIA-422/V.11 (X.27) PatchMate™
To meet the ever increasing bandwidth
requirements of data communications networks, the
EIA-422/V.11 (X.27) specifications were created.
Although the balanced serial binary digital interface
standards address electrical characteristics only, it
does define data signal transfer rates up to 10
Mbps. ADC's EIA-422/V.11 (X.27) PatchMate
products are designed and tested to support data
rates in excess of 13 Mbps. ADC has defined the
mechanical interface for 5 of the EIA-422/V.11
(X.27) balanced data and timing circuits, and the
remaining conductors are available for user
functional assignment.
EIA-422/V.11 (X.27) Summary
• Patches 25 leads
• Data rate up to 13 Mbps
• DB25 connector interface
• Key Type A and B available
• Balanced patch cords PMPC-B-X (Key Type B)
and PMP-6XX002 (Key Type A) are used
• Modules and patch cords are red (Key Type A)
and/or black (Key Type B)
EIA-422/V.11 (X.27) Pin Chart
1
14
15
16
17
18
19
20
21
22
23
24
25
2
3
4
Pin
Abbreviation
Description
1
FG
Frame Ground
2
TD
Transmitte Data (+)
Green
3
RD
Received Data (+)
Red
4
RTS
Request To Send
5
CTS
Clear To Send
6
DSR
Data Set Ready
7
SG
Signal Ground
8
DCD
Data Carrier Detect
LEDs
5
6
7
8
9
10
11
12
10
Negative DC Test Voltage
11
Unassigned
12
Unassigned
13
Unassigned
14
TD
Transmitted Data (-)
Green
15
Sync
Sync
Red
16
Sync
Sync
Red
517
Positive DC Test Voltage
17
RC
Received Clock (+)
Red
18
RC
Received Clock (-)
Red
19
RD
Received Data (-)
Red
•
13
9
20
DTR
Data Terminal Ready
12/02
Data Management and Access Products
Patch Cords
21
SQ
Signal Quality Detect
22
RI
Ring Indicator
23
TC
Transmitter Clock (-)
Green
24
TC
Transmitter Clock (+)
Green
25
w w w. a d c . c o m
•
Test Mode
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
33
EIA-422/V.11 (X.27) PatchMate™
Assemblies
EIA-422/V.11 LED CHART
• Weight: 11-13 lbs (5-6 kg)
Pin A
Pin B
Abbreviation
LEDs
• Patches 25 leads
2
14
TD
Green
• Data rate up to 13 Mbps
24
23
TC
Green
3
19
RD
Red
17
18
RC
Red
15
16
SYNC
Red
• DB25 connector interface
• Key Type A or B available
• Balanced patch cord PMPC-B-X (Key Type B)
and PMP-6XX002 (Key Type A) are used
• Modules and patch cord plugs are red
(Key Type A) or black (Key Type B)
Connector
Catalog
Number
Options
Components Included
Key
Rear/Top Rear/Bottom
(DTE)
(DCE)
LEDs Alarms Type
EIA-422
PMS-B-16-MF (P) DB25
PMS-616002 (P) DB25
(R) DB25
(R) DB25
QTY/Type
Patch Mod.
B 16 PMM-B-2
A 16 PMM-616002
QTY/Type Blank
Required
Other Mod. Mod. Chassis Power Supply
None
None
2
2
PMCH-2N
PMCH-2N
12/02
•
517
Data Management and Access Products
• Dimensions (H x W x D): 5.25 x 19 x 9 inches
(13.3 x 48.26 x 22.9 cm)
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
34
None
None
EIA-422/V.11 (X.27) PatchMate™
Balanced Patching without LEDs
or Alarms
• Includes 16, Key Type B, non-LED PMM-B-2
patching modules
• The monitor port is located on the top row of
jacks, with DCE (LINE) in the middle row, and
DTE (EQUIP) on the bottom row
• Modules and patch cords are black
• Use with patch cord PMPC-B-X
PMS-B-16-MF (P/R)
PMS-B-16-MF (R)
• No power supply is required
Balanced Key Type “A” Patching
without LEDs or Alarms
• Includes 16, Key Type A, non-LED PMM-616002
patching modules
• Key Type A makes it impossible to patch
between a standard Key Type B patch module
and the Key Type A version
• Modules and patch cords are red
• Black or grey modules available upon request
PMS-616002 (P/R)
• Use with patch cord PMP-6XX002
• No power supply is required
12/02
•
517
Data Management and Access Products
Assemblies
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
35
EIA-422/V.11 (X.27) PatchMate™
Modules
EIA-422/V.11 LED Chart
• Weight: 9 oz. (252 g)
Pin A
Pin B
Abbreviation
LEDs
• Patches 25 Leads
2
14
TD
Green
• Data rate up to 13 Mbps
24
23
TC
Green
• DB25 connector interface
3
19
RD
Red
• Key Type A or B available
17
18
RC
Red
• Balanced patch cords PMPC-B-X (Key Type B)
and PMP-6XX002 (Key Type A) are used
15
16
SYNC
Red
• Modules and patch cord plugs are red (Key Type
A) and black (Key Type B)
Connector
Catalog
Number
Module
Type
EIA-422
PMML-B-2
PMM-B-2
PMM-B-2 (R)
PMM-616002
PMME-B-1
PIMML-B-1
PIMML-B-2
Patch
Patch
Patch
Interface
Interface
Test
Patch
Rear/Top
(DTE)
(R) DB25
(R) DB25
(R) DB25
(R) DB25
(R) DB25
(P) DB25
(R) DB25
Rear/Bottom
(DCE)
Other
Key
Type
Color
•
B
B
B
A
Black
Black
Red
Red
•
•
B
B
Black
Black
LEDs
(P) DB25
(P) DB25
(P) DB25
(R) DB25
(R) DB25
Recommended Equipment
Chassis
PMCH-6
PMCH-2N or 6
PMCH-2N or 6
PMCH-2N or 6
PMCH-2N or 6
PMCH-6
PMCH-2N*or 6
Patch Cords
PMPC-B-X
PMPC-B-X
PMPC-B-X
PMP-6XX002
PMPC-B-X
PMPC-B-X
PMPC-B-X
P = Plug/Male Connector
R = Receptacle/Female Connector
* External power supply DMPS-11 or DMPS-11E is required when used in unpowered chassis PMCH-2N.
12/02
•
517
Data Management and Access Products
• Dimensions (H x W x D): 5.25 x 0.95 x 5.5
inches (13.3 x 2.41 x 13.97 cm)
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
36
EIA-422/V.11 (X.27) PatchMate™
Modules
Data Management and Access Products
Patch Module with LEDS and without Alarms
• Status indication is provided by
five LED indicators
INDICATORS
MONITOR
CIRCUITS
MONITOR
MONITOR
CIRCUIT
LINE (DCE)
LINE
EQUIP
• The monitor port is located in the
top jack
• Use with chassis PMCH-6 and
patch cord PMPC-B-X
EQUIP (DTE)
PMML-B-2 (R/P)
Patch Module without LEDS or Alarms
• Patches 25 leads of the interface
MONITOR
LINE (DCE)
• No power supply is required
LINE
EQUIP
• Use with chassis PMCH-2N or
PMCH-6 and patch cord
PMPC-B-X
EQUIP (DTE)
PMM-B-2 (R/P)
PMM-B-2 (R)
Key Type “A” Patch Module without LEDs or Alarms
• Reverse keying makes it impossible
to patch between a standard Key
Type B patch module and the
reverse Key Type A version
MONITOR
LINE (DCE)
• Modules and patch plugs are red
517
LINE
EQUIP
EQUIP (DTE)
• Use with chassis PMCH-2N and
patch cord PMP-6XX002
No power supply is required
12/02
•
•
PMM-616002 (R/P)
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
37
EIA-422/V.11 (X.27) PatchMate™
Modules
Data Management and Access Products
Interface Module with LEDs and without Alarms
• Allows test equipment or other
miscellaneous equipment to be
terminated within the chassis
FRONT
PANEL
ACCESS-1
MONITOR
CIRCUITS
TEST
EQUIP-2
FRONT
PANEL
ACCESS-2
INTERFACE
MODULE
• Unbalanced indicators (referenced
to pin 7) monitor RTS (pin 4), CTS
(pin 5) and DCD (pin 8)
PIMML-B-1 (R/R)
• Use with chassis PMCH-6
Interface Module without LEDs or Alarms
FRONT
PANEL
ACCESS-1
• Allows test equipment or other
miscellaneous equipment to be
terminated within the chassis
TEST
EQUIP-1
• Use with chassis PMCH-2N or
PMCH-6
TEST
EQUIP-2
FRONT
PANEL
ACCESS-2
• No power supply is required
INTERFACE
MODULE
PMME-B-1 (R/R)
Test Module with LEDs and without Alarms
INDICATOR
• Brings EIA-422/V.11(X.27) signal leads
to DB25 receptacle on front and DB25
plug on rear
MONITOR
CIRCUITS
RS422/V.11
(X.27) DB25 (F)
517
PATCHMATE
PORT
TEST
EQUIPMENT
CONNECTOR (M)
DMPS-11
POWER SUPPLY
(OPTIONAL)
• Balanced indicators monitor the status
of TD (pins 2 and 14), TC (pins 24 and
23), RD (pins 3 and 19), RC (pins 17
and 18), and XTC (pins 15 and 16)
• Unbalanced indicators (referenced to
pin 7) monitor RTS (pin 4), CTS (pin 5)
and DCD (pin 8)
•
12/02
• Balanced indicators monitor the
status of TD (pins 2 and 14), TC
(pins 24 and 23), RD (pins 3 and
19), RC (pins 17 and 18), and XTC
(pins 15 and 16)
TEST
EQUIP-1
• Use with chassis PMCH-2N or PMCH-6
PIMML-B-2 (R)
• External power supply DMPS-11 or
DMPS-11E is required when used in
unpowered chassis PMCH-2N
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
38
EIA-422/V.11 (X.27) PatchMate™
Chassis
517
Data Management and Access Products
Powered Chassis
Powered Chassis for PatchMate Modules
Requiring Power, LED and Alarming
• Designed to provide power to modules
with LEDs
• May also be used with unpowered modules
• Mounts up to 18 modules
PMCH-6
• Requires power supply DMPS-5 or DMPS-5E
• Chassis PMCH-6 is labeled to correspond with
EIA-422/V.11(X.27) modules
Unpowered Chassis
For Unpowered PatchMate Modules
• Designed to be used with modules that do not
require power
• Mounts up to 18 modules
• Chassis PMCH-2N is labeled to correspond with
EIA-422/V.11(X.27) modules
PMCH-2N
• LED test modules require the use of power
supply DMPS-11 or DMPS-11E when used in
chassis PMCH-2N
Module
Catalog Number
EIA-422/V.11 (X.27)
PMML-B-2
PMM-B-2
PMM-616002
PIMML-B-1
PIMML-B-2
PMM-B-2 (R)
PMCH-2
(Unpowered)
R
C
C
R
R
C
N
R
R
N
C
R
C = Compatible
N = Not Compatible
12/02
•
R = Recommended
PMCH-1
(Powered)
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
39
EIA-422/V.11 (X.27) PatchMate™
Patch Cords
Cord Type
Length (in feet)
Key Type
End Color
EIA-422 PatchMate
EIA-422 PatchMate
EIA-422 PatchMate
EIA-422 PatchMate
EIA-422 PatchMate
EIA-422 PatchMate
EIA-422 PatchMate
EIA-422 PatchMate
EIA-422 PatchMate
2
3
4
6
10
2
2
3
6
B
B
B
B
B
A
A
A
A
Black
Black
Black
Black
Black
Red
Grey
Red
Red
Catalog Number
EIA-422/V.11 (X.27)
PMPC-B-2
PMPC-B-3
PMPC-B-4
PMPC-B-6
PMPC-B-10
PMP-602002
PMP-602003
PMP-603002
PMP-606002
12/02
•
517
Data Management and Access Products
Balanced Patch Cords
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
40
PatchMate™
Power Supplies
Data Management and Access Products
110V-120V/60Hz Power Supply
Catalog Number: DMPS-5
• Will power one full chassis from a standard 110V/60Hz
power source
• Outlet mounted transformer
• Compatible with chassis PMCH-1 and PMCH-6
• Includes six foot (1.82 m) cable for attachment to patch chassis
DMPS-5
110V-120V/60Hz Power Supply
Catalog Number: DMPS-5A
• Required to power EIA-530 LED assemblies
• Input power cable
• Compatible with chassis PMCH-1 and PMCH-6
DMPS-5A
220V-240V/50Hz Power Supply
Catalog Number: DMPS-5E
• Will power one full chassis from a 220V-240V/50Hz power source
• Input power cable
• Compatible with chassis PMCH-1 and PMCH-6
DMPS-5E
-48 Vdc Power Supply
Catalog Number: DMPS-548
• Module converts -48 Vdc to power a full chassis
• Input power connections are made using screw terminals
• Occupies two slots in chassis PMCH-1 and PMCH-6
220V-240V/50Hz Power Supply
DMPS-548
• Used to power breakout or test modules in unpowered chassis
PMCH-2 or PMCH-2N
• Output cable is terminated with an inline connector
12/02
•
517
Catalog Number: DMPS-11E
110V-120V/60Hz Power Supply
Catalog Number: DMPS-11
DMPS-11E
• Used to power breakout or test modules in unpowered chassis
PMCH-2 or PMCH-2N
• Outlet mounted transformer
• Output cable is terminated with an inline connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
41
PatchMate™
Chassis
• Designed to provide power to modules, LEDs
and alarms
• May also be used with unpowered modules
• Mounts up to 18 modules
Catalog Number: PMCH-1
• Labeled to correspond with all PatchMate
EIA-530, EIA-232/V.24 and V.35 modules
• Requires power supply DMPS-5A when used
with EIA-530 assemblies and modules
PMCH-1
• Requires power supply DMPS-5, DMPS-5E or
DMPS-548 when used with EIA-232/V.24 and
V.35 assemblies and modules
Catalog Number: PMCH-6
• Compatible with EIA-422/V.11 (X.27) modules
• Labeled to correspond with the port
arrangement on modules PMML-B-2, PMM-B-2
and PMM-616002
• Requires power supply DMPS-5, DMPS-5E or
DMPS-548
PMCH-6
Unpowered Chassis
• Designed to be used with modules that do not
require power
• Mounts up to 18 modules
• LED breakout and test modules require the use of
power supply DMPS-11 or DMPS-11E
when used in unpowered chassis PMCH-2
or PMCH-2N
PMCH-2-3
Catalog Number: PMCH-2, PMCH-2-3,
PMCH-2-9
• Labeled to correspond with all PatchMate
EIA-530, EIA-232/V.24 and V.35 modules
•
517
Data Management and Access Products
Powered Chassis
12/02
• Mini-chassis 3 or 9 position available
Catalog Number: PMCH-2N
• Compatible with EIA-422/V.11 (X.27) modules
• Chassis PMCH-2N is labeled to correspond with
the port arrangement on modules PMML-B-2,
PMM-B-2 and PMM-616002
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
PMCH-2N
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
42
PatchMate™
Chassis
12/02
•
517
Data Management and Access Products
Compatibility Chart
Powered
Unpowered
Catalog Number
PMCH-1
PMCH-6
PMCH-2
PMCH-2N
PMCH-2-3
PMCH-2-9
EIA-530
PMM-614001
PMM-616001
PMM-616004
PMM-616004RED
PMM-616005
PMM-616003
PMBP-530-2
PMBP-530-1
R
C
C
C
C
C
R
C
N
N
N
N
N
N
N
N
N
R
R
R
R
R
C*
R
N
N
N
N
N
N
N
N
N
R
R
R
N
N
N
N
N
R
R
R
N
N
N
N
R
R
R
R
C
C
C
R
R
C
C
R
C
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
R
R
R
N
C*
R
R
C*
R
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
R
N
N
N
N
N
N
N
N
N
N
N
N
R
N
N
N
N
N
N
N
N
EIA-232/V.24
PMMLA-1
PMMLA-2
PMML-1
PMML-2
PMM-1
PMM-2
PMM-2 (R)
PIMMLA-1
PIMMLA-2
PMME-1
PMME-2
PMBP-2
PMBP-1
Mount up to 17 V.35 modules in positions 1 through 17
Mounting V.35 requires accessory BKT-V.35 (cable support bar)
V.35
PMMLA-V35FF
PMMLA-V35
PMM-V35FF
PMM-V35
PIMMLA-V35
PMME-V35
R
R
C
C
R
C
N
N
N
N
N
N
N
N
R
R
N
R
N
N
N
N
N
N
N
N
N
R
N
N
N
N
N
R
N
N
EIA-422/V.11 (X.27)
PMML-B-2
PMM-B-2
PMM-616002
PMME-B-1
PIMML-B-2
PMM-B-2 (R)
N
N
N
N
N
N
R
C
C
C
R
C
N
N
N
N
N
N
N
R
R
R
C*
R
N
R
N
N
N
N
N
R
N
N
N
N
R = Recommended
C = Compatible
N = Not Compatible
* LED breakout and test modules require power supply DMPS-11 or DMPS-11E when used in
unpowered chassis PMCH-2 or PMCH-2N.
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
43
PatchMate™
Accessories
12/02
•
517
Data Management and Access Products
Designation Strip and Card Replacement Kit
Catalog Number: DSK-1
• Replacement designation strip base kit used on all top mount 1/4"
designation strips on PatchMate and PatchSwitch assemblies
Designation Strips, Windows and Cards
• Replacement 1/4" and 1/2" designation strips, windows and
cards; sold individually
Description
Catalog Number
1/4" Height
Catalog Number
1/2" Height
Designation Strips
PMO-000006
PMO-000009
Designation Windows
PMO-000002
PMO-000010
Designation Cards
PMO-000003
PMO-000004
Designation Strip Kit
PMO-000011
PMO-100001
Screw Base Replacement Kit
Catalog Number: PMDS-1
• Replacement designation strip base kit used on all top mount 1/4"
designation strips on PatchMate and PatchSwitch assemblies
• Termination Tool: PMLP-TOOL
Data Circuit Guards
Catalog Number: PMCG-1, PMCG-2
• Can be inserted into any PatchMate or PatchSwitch patch jacks to
keep technicians from accidentally patching critical circuits
• Does not activiate the circuit on insertion
• PMCG-1 is red
• PMCG-2 is white
Blank Panels
Catalog Number: PMBF-1, PMBF-1 (R), PMM-030001
•
•
•
•
•
•
For use with chassis PMCH-1, PMCH-2, PMCH-6 or PMCH-2N
Use to fill unused slots
Assemblies often come with one or two blank panels
PMBF-1 is black
PMBF-1(R) is red
PMM-030001 is grey
Cable Support Bar Kit
Catalog Number: BKT-V35
• Contains two extended support bars and attachment hardware
• Kit is required for use on any PatchMate chassis with V.35 modules
Miscellaneous
Catalog Number: PMDP-530-A
• Dummy plug can only be used in EIA-530 System
Catalog Number: EB-52B
• Extender bracket for 23” chassis
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
44
PatchMate™
Accessories
517
Data Management and Access Products
Alarm Breakout Panel
Catalog Number: DMBP-1
• Provides monitoring, maintenance and
test capabilities
• May be used as a stand-alone unit or as an
accessory to a PatchMate system
• Front panel offers LED (red and green) indications of
data signals, simulation of control signals, and
patching of an alarm pulse catcher to any of 23 leads
• Two LEDs (+ and -) are provided for each of the 23 leads
• Connected or patched to the data circuit at the EIA-232 interface between the modem and the
terminal equipment
• The 23 leads are then accessible at the front of the alarm/breakout panel for monitoring, breakoff and
testing by using a DMPJ-1 pin jack patch cord kit
• Signal faults are quickly and easily detected by visual indicators and/or audible alarm
• Special PatchMate PMCPC-PM-X patch cords and DMPJ-1 pin jack cords are recommended
• Self-contained power supply with integral AC line card
Pin Jack Jumper Kit
Catalog Number: DMPJ-1
• Contains four 12" (30.5 cm) pin jack jumper cords and
one 18" (46 cm) pin jack jumper cord
• Used with the DMBP-1 alarm breakout panel (above)
DMBP-1 Alarm Breakout Panel Patch Cords
• Converts PatchMate Key Type B plug to
DMBP-1 patch plug
Catalog Number
Connector
Type
Length
(in feet)
PMCPC-PM-4
PMCPC-PM-6
Alarm Panel
Alarm Panel
4
6
Looping Plugs
Catalog Numbers: PMLP-4, PMLP-5, PMLP-6
• Can be inserted into any patch jack to loop signals back toward
DTE or DCE
• The PMLP-4 plug has jumpers between pins 2/3, 14/19, 17/24
and 18/23
12/02
•
• The PMLP-5 plug has jumpers between pins 2/3 and 15/17
• The PMLP-6 plug has jumpers between pins 2/4, 3/5, 14/16
and 15/17
Customized Looping Plugs
• Custom versions are created by simply moving the jumper wires inside
each plug
• Loop Plug Kit- Key Type A: PMLP-KIT-A
• Loop Plug Kit- Key Type B: PMLP-KIT-B
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
45
PatchSwitch™
Data Management and Access Products
Introduction
The PatchSwitch product line provides a convenient, organized method of digital communications line
access and reconfiguration. The system is completely modular, compatible with most PatchMate products,
and may easily be configured to meet the exact needs of your network.
PatchSwitch Product Line
Switching Mechanism
• Local or remote A/B fallback switching
initiated automatically or by user
• Hermetically sealed, magnetically latched
electromechanical relays consume less
power and do not "scatter" on power up
or down
• Rapidly switch large groups of lines to
standby circuits
• Manual access for port or line sparing,
monitoring, testing and reconfiguring
• Exclusive automatic A/B fallback switches
to a secondary line/device if the primary
causes an alarm
• Optional alarming and LEDs indicate circuit
health
• Controlled by a simple toggle switch
located on the front of each module
• Modules can be removed without
disconnecting cables
• Switches 23 leads on the active interface
• Off-line port access available (most vendors
block this access)
• Modules may be switched individually or in
groups of up to 256 modules
Remote Control
• Standard capability, not an extra cost option
• Control via ASC II commands (RS 422) or
DC voltage
• Most flexible capability on the market
Alarms and LEDs
• “At a glance” circuit diagnostics
• Eight data line status indicators and alarm
circuitry per module
• Green and red LEDs indicate the real time
status signal leads
Patch Cords and Leads
• Patches 24 leads
517
• Contacts are gold inlaid and bifurcated to
prevent wear, oxidation or material breakdown
•
• Patented spring to spring contact provides
solid, reliable connections
• Contacts are fully recessed to prevent breakage
or contamination
12/02
• Accidental switching is prevented by an
“enable” switch located on the control
module
• Instantly tailor alarm conditions to changing
needs without module removal
• Controlled by a simple toggle switch located
on the front of each module
• Alarming is on with absence of an electrical
signal
• Choose "Alarm Off", "Audible and Visual
Alarm", or "Visual Alarm Only"
• Select delay from 50µ seconds to 68 seconds
• Cords are keyed to prevent improper insertion
and are fully strain relieved
• Reset by touching two contacts on the front
of the module
• Mounting hardware is captive to prevent
dropped or lost parts
• Most complete feature set on the market
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
46
PatchSwitch™
Introduction
If you need automatic network
control capabilities, use this
decision tree to guide you
through the selection of a
complete PatchSwitch system
Do you need a fully preconfigured
16 circuit assembly?
YES
NO
Do you need
LEDs or alarms?
Do you need
LEDs or alarms?
YES
NO
NO
YES
Choose
Modules
See pages
51-52.
See pages
51-52.
Choose
Accessories
Choose
Chassis
Choose
Chassis
See pages
55-56.
See page 53.
See page 53.
Choose
Assembly
Choose
Assembly
See page 49.
See page 49.
Choose
Accessories
See pages
55-56.
Choose
Modules
Choose
Power Supply
Choose
Power Supply
See page 54.
See page 54.
Choose
Patch Cords
See page 53.
Choose
Other Accessories
See pages 55-56.
12/02
•
517
Data Management and Access Products
PatchSwitch™ Decision Tree
PLACE
ORDER
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
47
PatchSwitch™
Summary
PatchSwitch Summary
• Data rate of DC to 19.2 Kbps
• DB25 connector interface
• Key Type B
• Unbalanced patch cord (PMPC-X) available in 2-10 foot lengths
• Modules and patch cords are black
PatchSwitch™ Pin Chart
1
14
15
16
17
18
19
20
21
22
23
24
25
2
3
4
5
Pin
Abbreviation
Description
1
FG
Frame Ground
2
TD
Transmitted Data
Green
3
RD
Received Data
Green
4
RTS
Request to Send
Red
5
CTS
Clear to Send
Red
6
DSR
Data Set Ready
REd
7
SG
Signal Ground
8
DCD
Data Carrier Detect
LEDs
6
7
8
9
10
9
Positive DC Test Voltage
10
Negative DC Test Voltage
11
Unassigned
Green
11
12
13
12
SCD
Secondary Received Line Detector
13
SCS
Secondary Clear to Send
14
STD
Secondary Transmitted Data
15
TC
Transmitter Clock
16
SRD
Secondary Received Data
17
RC
Received Clock
18
LL
Local Loopback
19
SRS
Secondary Request to Send
20
DTR
Data Terminal Ready
Red
21
SQ
Signal Quality Detect
Green
22
RI
Ring Indicator
23
CH
Data Signal Rate Selector
24
ETC
External Transmitter Clock
25
TM
Test Mode
12/02
•
517
Data Management and Access Products
• Patching and/or A/B fallback switching for 23 active leads
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
48
PatchSwitch™
Assemblies
PatchSwitch™ LED Chart
12/02
•
517
Data Management and Access Products
• Sixteen switching modules in the leftmost
positions
• The seventeenth slot of the chassis is filled with
a blank
• The eighteenth slot of the chassis is filled with a
control module
• Control module provides gang or block
switching, switch operation enable, master
alarm reset, auto fallback switching and remote
control switch processing
• Switch interlock feature permits “B” state
switching by only one group of lines at a time
• Equipped to permit local or remote control
Pin A
Abbreviation
LEDs
2
TD
Green
3
RD
Green
4
RTS
Red
5
CTS
Red
6
DSR
Red
8
DCD
Green
20
DTR
Red
21
SQ
Green
• Power supply DMPS-10 or PSW-000003
required
• Dimensions (H x W x D): 7 x 19 x 11 inches
(17.8 x 48.26 x 28 cm)
• Weight: 20 lbs (9 kg)
• Patches and/or A/B fallback switching for 23
active leads
• Data rate of DC up to 19.2 Kbps
• DB25 connector interface
• Key Type B
• Patch cord (PMPC-X) available in 2-10 foot
lengths
• Modules and patch cords are black
Connector
Catalog
Number
Components Included
LEDs and
Rear/Top &
Rear/Bottom Inline
Rear/Middle (DTE)
(DCE)
Patching Alarms
PSA-02D
PSA-04D
(R) DB25
(R) DB25
Catalog Number
PSA-02D
PSA-04D
(P) DB25
(P) DB25
•
•
•
Power Supply
Patch Cords
DMPS-10 or PSW-000003
DMPS-10 or PSW-000003
PMPC-X
PMPC-X
QTY/Type
Patch Mod.
16 PSM-01
16 PSM-02
Blank Control Chassis
Mod. Mod.
1
1
1
1
RDC-01D
RDC-02D
Compatible
Interface
Module
PSM-08
PSM-08
P = Plug/Male Connector
R = Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
49
PatchSwitch™
LED/Alarm A/B Switching with
Inline Patch Access
• Provides 16 lines of PSM-01 in-line EIA-232/V.24
digital patching with switching
• Each PSM-01 module contains eight signal
monitoring LEDs and alarming circuitry
• Alarming is selectable on any one of the eight
leads monitored
• Assemblies are selectable for “auto-fallback”
automatic restoral switching upon alarm
• Remote switching capability included
PSA-02D (R/R/P)
• PSA-01C uses RDC-01D chassis
A/B Switching with Inline
Patch Access
• Includes 16, Key Type B, non-LED PMM-02
patching modules
• The monitor port is located on the top row of
jacks, with DCE (LINE) in the middle row, and
DTE (EQUIP) on the bottom row
• Modules and patch cords are black
PSA-04D (R/R/P)
• Use with patch cord PMPC-B-X
12/02
•
517
Data Management and Access Products
Assemblies
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
50
PatchSwitch™
Modules
PatchSwitch™ LED Chart
• Inline patching allows the user full intrusive
(break) and passive (monitor) access to the
active or on-line circuit currently switched to
service
Pin A
Abbreviation
LEDs
2
TD
Green
3
RD
Green
• Fallback switching is accomplished by holding
the “enable” switch and then moving a toggle
switch momentarily to “A” or “B”
4
RTS
Red
5
CTS
Red
6
DSR
Red
8
DCD
Green
20
DTR
Red
21
SQ
Green
• Red/green LEDs give visual feedback of current
switch status
• Modules mount interchangeably into either
RDC-01C or RDC-02C chassis
• Power supply DMPS-10 or PSW-000003
required
• Dimensions (H x W x D): 7 x .95 x 10 inches
(17.8 x 2.41 x 25.4 cm)
• Weight: 1 lb (.45 kg)
• Patching and/or A/B fallback switching for 23
active leads
• Data rate of DC up to 19.2 Kbps
• DB25 connector interface
• Key Type B
• Balanced patch cord (PMPC-X) available in 2-10
foot lengths
• Modules and patch cords are black
Options
Catalog
Number
Module
Type
PSM-01
PSM-02
PSM-08
PSR-06A
PSM-05A
PSM-07
PSM-09
PSM-18
PSM-19
PSR-05
Inline Patch
Inline Patch
Interface
RS232 Converter
Blank
Interface
Blank
LED and Rear/Bottom
Alarms
(DCE)
•
•
•
•
•
•
Required Products
Chassis
RDC-01D
RDC-01D
RDC-01D
RDC-01D
RDC-01D
RDC-01D
RDC-01D
Patch Cords
Interface
PMPC-X
PMPC-X
PMPC-X
None
PMPC-X
PMPC-X
None
RS232
RS232
RS232
RS232
RS232
RS232
•
•
RS422 Converter
None
V.35
V.35
RS232
12/02
•
517
Data Management and Access Products
• Patch modules contain up to three front panel
jacks for easy access to the circuit
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
51
PatchSwitch™
Modules
• Includes eight LED data line status
indicators and alarm circuitry
A/B
SWITCH
INDICATORS
COMPUTER
MONITOR
CIRCUIT
A DTE-A
B DTE-B
MODEM
C DCE
MONITOR
• Front panel selection switch allows
choice of alarms “OFF”, “Audible
and Visual Alarm”, or “Visual
Alarm Only”
• An eight position rotary switch
allows selection of alarm delay
between 1 microsecond and 68
seconds
• May be configured into “auto
fallback” mode, permitting restoral
switching whenever alarm
condition is sensed
PSM-01
Inline Patching with A/B Switching
A/B
SWITCH
COMPUTER
A DTE-A
MODEM
B DTE-B
• Provides patch access with switching
C DCE
MONITOR
PSM-02
Patch Interface
517
Data Management and Access Products
LED/Alarm Inline Patching with A/B Switching
TEST
EQUIP-1
FRONT
PANEL
ACCESS-1
•
TEST
EQUIP-2
• Provides two front panel jacks
which provide direct connection to
two connectors on the backplane
of the chassis
12/02
FRONT
PANEL
ACCESS-2
INTERFACE
MODULE
PSM-08
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
52
PatchSwitch™
Chassis
Data Management and Access Products
• A rack mountable card cage designed to hold
up to 17 modules
• Equipped with a control module mounted in
18th position
• Consists of a backplane with connectors for
switch cards and customer cabling and a sheet
metal card cage
• The card slot has two receptacle connectors for
use with auxiliary modules such as the RS232
interface conversion module (PSR-06A) or test
module (PSM-12)
• The DCE connections (common) associated with
each of the switch card positions (1-16) are
receptacles on the RDC-01D; the DTE
connections on both are receptacles
• Two DB9 receptacle connectors are provided to
permit EIA-422 or DC voltage remote control
equipment to be connected to the chassis
• A power supply DMPS-10 or PSW-000003 is
required
• Dimensions (H x W x D): 7 x 19 x 11 inches
(17.8 x 48.26 x 28 cm)
• Weight: 11 lbs (5 kg)
PatchSwitch™ Patch Cords
• Unbalanced, Key Type B
• Patch cord (PMPC-X) available in 2-10 foot
lengths
• Plug is black; cord is grey
517
Catalog Number
PMPC-2
PMPC-3
PMPC-4
PMPC-6
PMPC-10
Cord Type
Length (in feet)
EIA-232/V.24 PatchMate
EIA-232/V.24 PatchMate
EIA-232/V.24 PatchMate
EIA-232/V.24 PatchMate
EIA-232/V.24 PatchMate
2
3
4
6
10
12/02
•
RDC-01D (R/R/P)
P= Plug/Male Connector
R= Receptacle/Female Connector
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
53
PatchSwitch™
Power Supply
• Supplies power to any PatchSwitch chassis
• Use with either 110V/60Hz or 220V/50Hz power sources
• 19" rack mountable chassis
• Equipped with one power supply
• Easy installation of up to 3 additional power supplies (DMPS-10EXP)
DMPS-10
• UL, CSA, VDE and IEC approved
• Dimensions (H x W x D): 3.5 x 19 x 11.5 inches
(8.89 x 48.26 x 29.21 cm)
• Weight: 12 lb (5.4 kg)
General Module Power Supply
• Supplies power to any PatchSwitch chassis
• Use with AC power sources ranging from 90-240V and 47-63Hz
• Need for surge protectors, line filters or power line conditioners
depends on local power conditions
• UL, CSA, VDE and IEC approved
• Dimensions (H x W x D): 3.75 x 3.5 x 6 inches (9.5 x 8.9 x 15.5 cm)
PSW-000003
• Weight: 1.2 lb (0.54 kg)
12/02
•
517
Data Management and Access Products
Multi-module Power Supply
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
54
PatchSwitch™
Accessories
Catalog Number: PSM-09
• Use to fill unused slots in PatchSwitch RDC-01D chassis or
assemblies
Designation Strip Panel
Catalog Number: PSR-04
• Panel is normally mounted above the PSR-03 so that the operator
can easily label and organize either 4 or 8 chassis that may be
under the control of the remote control unit
• PSR-04 holds up to 4 designation strips
Designation Strip and Card Replacement Kit
Catalog Number: DSK-1
• Replacement designation strip base kit used on all top mount 1/4"
designation strips on PatchMate and PatchSwitch assemblies
Designation Strips, Windows and Cards
• Replacement 1/4" and 1/2" designation strips, windows and cards;
sold individually
Ordering Information
Description
Catalog Number
1/4" Height
Catalog Number
1/2" Height
Designation Strips
PMO-000006
PMO-000009
Designation Windows
PMO-000002
PMO-000010
Designation Cards
PMO-000003
PMO-000004
Screw Base Replacement Kit
Catalog Number: PMDS-1
• Replacement designation strip base kit used on all top mount 1/4"
designation strips on PatchMate and PatchSwitch assemblies
Data Circuit Guards
•
517
Data Management and Access Products
Blank Module
12/02
Catalog Number: PMCG-1, PMCG-2
• Can be inserted into any PatchMate or PatchSwitch circuit to keep
technicians from accidentally patching critical circuits
• Does not activiate the circuit on insertion
• PMCG-1 is red
• PMCG-2 is white
• PMCG-3, no key type
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
55
PatchSwitch™
Accessories
Catalog Number: PSCC9-2
• Used to connect a PSR-03 remote control interface module to the
first PatchSwitch chassis
• Can daisy chain up to 16 RDC-01C PatchSwitch chassis or
assemblies together
Looping Plugs
Catalog Number: PMLP-4, PMLP-5, PMLP-6
• Can be inserted into any patch jack to loop signals back toward
DTE or DCE
• The PMLP-4 plug has jumps between pin 2/3, 14/19, 17/24 and
18/23
• The PMLP-5 plug has jumpers between pins 2/3 and 15/17
• The PMLP-6 plug has jumpers between pins 2/4, 3/5, 14/16
and 15/17
Customized Looping Plugs
• Custom versions are created by simply moving the jumper wires
inside each plug
• Loop Plug Kit- Key Type A: PMLP-KIT-A
• Loop Plug Kit- Key Type B: PMLP-KIT-B
12/02
•
517
Data Management and Access Products
Remote Control Switch Controller Cables
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
56
PatchMate™
12/02
•
517
Data Management and Access Products
Specifications – Assemblies
Catalog
Number
Key
Type Color
Data Rate
EIA-530
PMM-614001
A
Grey
DC to 20 Mbps
PMM-616001
A
Grey
DC to 5 Mbps
PMM-616004
A
Grey
DC to 20 Mbps
PMM-616004RED
B
Red
DC to 20 Mbps
PMM-616005
A
Grey
DC to 20 Mbps
PMM-616005RED
B
Red
DC to 20 Mbps
EIA-232/V.24
PMSLA-16
B
Black
DC to 19.2 K
PMSLA-16MF
B
Black
DC to 19.2 K
PMSLA-16 (R)
B
Red
DC to 19.2 K
PMSLA-16 (G)
B
Grey
DC to 19.2 K
PMSL-16
B
Black
DC to 19.2 K
PMSL-16-MF
B
Black
DC to 19.2 K
PMS-16
B
Black
DC to 19.2 K
PMS-16-MF
B
Black
DC to 19.2 K
V.35
PMSLA-V35FF
B
Grey
DC to 2 Mbps
PMSLA-16-V35
B
Grey
DC to 2 Mbps
PMS-16-V35FF
B
Grey
DC to 2 Mbps
PMS-16-V35
B
Grey
DC to 2 Mbps
w w w. a d c . c o m
•
Dimensions
(H x W x D)
System
Weight Input Power
Power
Consumption
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
8 VAC
@47-60Hz
8 VAC
@47-60Hz
None
None
None
None
None
None
None
None
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
8 VAC
@47-60Hz
8 VAC
@47-60Hz
8 VAC
@47-60Hz
8 VAC
@47-60Hz
8 VAC
@47-60Hz
8 VAC
@47-60Hz
None
17W
None
None
None
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
8 VAC
@47-60Hz
8 VAC
@47-60Hz
8 VAC
@47-60Hz
8 VAC
@47-60Hz
17W
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
38W
38W
17W
17W
17W
17W
17W
17W
17W
17W
57
PatchMate™
Specifications – Assemblies
Key
Type Color
Data Rate
EIA-422/V.11(X.27)
PMSL-B-17
B
Black
DC to 13 Mbps
PMS-B-16-MF
B
Black
DC to 13 Mbps
PMS-B-16-MF (R)
B
Red
DC to 13 Mbps
PMS-616002
A
Red
DC to 13 Mbps
Dimensions
(H x W x D)
Weight
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
5.25”x19”x9”
(13.3x48.26x22.9cm)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
13 lbs
(6 kg)
System
Power
Input Power Consumption
8 VAC
@47-60Hz
None
17W
None
None
None
None
None
Unless otherwise noted, all ADC PatchMate and PatchSwitch equipment conforms to the following
environmental specifications:
Temperature
Operating:
0°C to +50°C
Storage:
-40°C to +70°C
Humidity
Operating and
Storage:
5% to 95% relative humidity (no condensation)
12/02
•
517
Data Management and Access Products
Catalog
Number
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
58
PatchMate™
Specifications – Modules
EIA-530
PMM-614001
A
Grey
PMM-616001
A
Black DC to 20 Mbps
PMM-616004
A
Grey
DC to 20 Mbps
PMM-616004RED
B
Red
DC to 20 Mbps
PMM-616005
A
Grey
DC to 20 Mbps
PMM-636001
A
Red
DC to 20 Mbps
PMM-636003
A
Grey
DC to 20 Mbps
PMM-636003RED
B
Red
DC to 20 Mbps
PMBP-530-1
A
Grey
DC to 5 Mbps
PMBP-530-2
A
Grey
DC to 5 Mbps
PMME-5
A
Grey
DC to 20 Mbps
EIA-232/V.24
PMMLA-1
B
Black
DC to 19.2 K
PMMLA-2
B
Black
DC to 19.2 K
PMML-1
B
Black
DC to 19.2 K
PMML-2
B
Black
DC to 19.2 K
PIMM-1
B
Black
DC to 19.2 K
517
Data Rate
PMM-2
B
Black
DC to 19.2 K
PMM-2 (R)
B
Red
DC to 19.2 K
•
Key
Type Color
PIMMLA-1
B
Black
DC to 19.2 K
12/02
Data Management and Access Products
Catalog
Number
PMME-1
B
Black
DC to 19.2 K
w w w. a d c . c o m
•
DC to 5 Mbps
Power
System
Input Power Consumption
Dimensions
(H x W x D)
Weight
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
+5 Vdc
unfiltered
None
1.8W
None
None
None
None
None
None
None
None
None
None
None
None
None
None
+5 Vdc
unfiltered
None
1.8W
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
+5 Vdc
unfiltered
+5 Vdc
unfiltered
+5 Vdc
unfiltered
+5 Vdc
unfiltered
None
1W
None
None
None
None
None
+5 Vdc
unfiltered
None
1W
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
None
None
1W
1W
1W
None
59
PatchMate™
Specifications – Modules
Key
Type Color
Data Rate
EIA-232/V.24
PIMMLA-2
B
Black DC to 19.2 K
PMME-2
B
Black DC to 19.2 K
PMBP-1
B
Black DC to 19.2 K
PMBP-2
B
Black DC to 19.2 K
V.35
PMMLA-V35FF
B
Grey
DC to 64 K
PMMLA-V35
B
Grey
DC to 64 K
PMM-V35FF
B
Grey
DC to 64 K
PMM-V35
B
Grey
DC to 64 K
PIMMLA-V35
B
Grey
DC to 64 K
PMME-V35
B
Grey
DC to 64 K
Dimensions
System
Weight Input Power
Power
Consumption
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
+5 Vdc
unfiltered
None
1W
None
NA
+5 Vdc
unfiltered
1.5W
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
9 oz
(25 g)
9 oz
(25 g)
9 oz
(25 g)
9 oz
(25 g)
9 oz
(25 g)
9 oz
(25 g)
+5 Vdc
unfiltered
+5 Vdc
unfiltered
None
1W
None
NA
+5 Vdc
unfiltered
None
1W
NA
1W
NA
NA
12/02
•
517
Data Management and Access Products
Catalog
Number
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
60
PatchMate™
Specifications – Modules
Key
Type Color
Power
System
Weight Input Power Consumption
Dimensions
(H x W x D)
Data Rate
EIA-422/V.11(X.27)
PIMML-B-1
B
Black DC to 13 Mbps
PIMML-B-2
B
Black DC to 13 Mbps
PMM-B-2
B
Black DC to 13 Mbps
PMM-616002
A
Red
PMME-B-1
B
Black DC to 13 Mbps
PMME-B-2 (R)
B
Red
PMML-B-2
B
Black DC to 13 Mbps
DC to 13 Mbps
DC to 13 Mbps
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
5.25”x0.95”x9.6”
(13.3x2.41x24.5cm)
5.25”x0.95”x5.5”
(13.3x2.41x14.0cm)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
8 oz
(224 g)
+5 Vdc
unfiltered
+5 Vdc
unfiltered
None
1W
+5 Vdc
unfiltered
None
NA
None
NA
+5 Vdc
unfiltered
1W
1W
NA
NA
Specifications – Chassis
Catalog
Number
Dimensions
(H x W x D)
Weight
Required
Power
Power
Consumption
PMCH-1
5.25" x 19" x 9"
(13.3 x 48.26 x 23.9 cm)
8.8 lbs
(4.02 kg)
7 VAC
@ 47-60 MHz
2.5W
PMCH-2
5.25" x 19" x 9"
(13.3 x 48.26 x 23.9 cm)
8.2 lbs
(4.0 kg)
None
NA
PMCH-2N
5.25" x 19" x 9"
(13.3 x 48.26 x 23.9 cm)
8.2 lbs
(4.0 kg)
None
NA
PMCH-6
5.25" x 19" x 9"
(13.3 x 48.26 x 23.9 cm)
8.2 lbs
(4.0 kg)
7 VAC
@ 47-60 MHz
2.5W
PMCH-2-3
1.75" x 19" x 12.03"
(4.45 x 48.26 x 30.5 cm)
7.49 lbs
(4.5 g)
None
NA
PMCH-2-9
3.5" x 19" x 12.03"
(8.89 x 48.26 x 30.5 cm)
1 lbs
(4.5 g)
None
NA
12/02
•
517
Data Management and Access Products
Catalog
Number
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
61
PatchMate™
Specifications
Catalog
Number
Dimensions
(H x W x D)
Weight
Required
Power
Power
Consumption
DMPS-5
3.3" x 2.7" x 2.2"
(8.4 x 6.9 x 5.6 cm)
1.5 lb
(.7 kg)
110 VAC @
47-60 Hz 250 mA
25W
DMPS-11
3.3" x 2.7" x 2.2"
(8.4 x 6.9 x 5.6 cm)
1.5 lb
(.7 kg)
110 VAC @
47-60 Hz 250 mA
25W
DMPS-5E
2.5" x 2.75" x 4.75"
(5.71 x 7.0 x 12.0 cm)
2 lb
(.9 kg)
110 VAC @
47-63 Hz 125 mA
25W
DMPS-11E
2.5" x 2.75" x 4.75"
(5.71 x 7.0 x 12.0 cm)
2 lb
(.9 lb)
110 VAC @
47-63 Hz 125 mA
25W
DMPS-548
2.5" x 2.75" x 4.75"
(13.3 x 5.0 x 14.0 cm)
1.5 lb
(.7 kg)
-48 Vdc @ .75 amps
25W
Catalog
Number
Key
Type
Color
Data Rate
DMBP-1
DM
Black
DC to 19.2 K
Dimensions
(H x W x D)
Weight
Required
Power
1.75”x19”x10”
(4.4x48.3x25.5cm)
11 lbs
(5 kg)
120 VAC
@47-60 Hz
12/02
•
517
Data Management and Access Products
Power Supplies
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
62
PatchSwitch™
Specifications
Dimensions
(H x W x D)
Weight
System
Input Power
Power
Consumption
DC to 19.2 K
7” x 19 x 11
(17.8 x 48.2 x 28 cm)
20 oz
(9 kg)
+5 Vdc @ 5 amps
+12 Vdc @ 1 amp
25W
DC to 19.2 K
7” x 19 x 11
(17.8 x 48.2 x 28 cm)
20 oz
(9 kg)
+5 Vdc @ 5 amps
+12 Vdc @ 1 amp
25W
Catalog
Number
Key
Type
Color
Data Rate
PSA-02D
B
Black
PSA-04D
B
Black
Modules
Catalog
Number
Key
Type Color
Data Rate
PSM-01
B
Black
DC to 19.2 K
PSM-02
B
Black
DC to 19.2 K
PSM-05A
B
Black
DC to 19.2 K
PSM-07
B
Black
DC to 19.2 K
PSM-08
B
Black
DC to 19.2 K
PSM-09
B
Black
None
PSM-18
B
Black
DC to 19.2 K
PSM-19
B
Black
DC to 19.2 K
PSR-05
B
Black
DC to 19.2 K
PSR-06A
B
Black
DC to 19.2 K
Dimensions
(H x W x D)
Weight
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
7”x0.95”x10”
(17.8x2.41x25.4cm)
1 lb
(0.45 kg)
1 lb
(0.45 kg)
1 lb
(0.45 kg)
1 lb
(0.45 kg)
1 lb
(0.45 kg)
.25 lb
(0.12 kg)
1 lb
(0.45 kg)
1 lb
(0.45 kg)
1 lb
(0.45 kg)
1 lb
(0.45 kg)
System
Input Power
Power
Consumption
+5Vdc @ 200 mA
+12Vdc @ 1 amp
+5Vdc @ 200 mA
+12Vdc @ 1 amp
+5Vdc @ 150 mA
+12Vdc @ 50 mA
+5Vdc @ 200 mA
+12Vdc @ 1 amp
None
1.5W
750 mW
None
NA
+5Vdc @ 200 mA
+12Vdc @ 1 amp
+5Vdc @ 200 mA
+12Vdc @ 1 amp
+5Vdc @ 150 mA
+12Vdc @ 50 mA
+5Vdc @ 150 mA
+12Vdc @ 50 mA
1.5W
1.2W
1.5W
NA
1.5W
750 mW
750 mW
12/02
•
517
Data Management and Access Products
Assemblies
w w w. a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
63
PatchSwitch™
Specifications
RTA Chassis
Catalog
Number
Dimensions
(H x W x D)
Weight
Required
Power
Power
Consumption
RDC-01D
7" x 19" x 11"
(17.8 x 48.26 x 28.0 cm)
11 lb
(5 kg)
+5 Vdc @ 5 amps
+12 Vdc @ 1 amp
750 mW
3.75" x 3.5" x 6"
(9.5 x 8.9 x 15.5 cm)
1.2 lb
(.54 kg)
90-250 VAC @ 47-63 Hz
.7 amps max
30W
3.5" x 19" x 11.5"
(8.89 x 48.26 x 29.21 cm)
12 lb
(5.4 kg)
0-250 VAC @ 47-63 Hz
.7 amps max
108W
3.75" x 4.25" x 10.13"
(9.5 x 10.8 x 25.73 cm)
3 lb
(1.35 kg)
0-250 VAC @ 47-63 Hz
.7 amps max
27W
PSW-000003
DMPS-10
DMPS-10EXP
Web Site: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-946-3292
For a complete listing of ADC's global sales office locations, please refer to our Web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously improving our
products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by
contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate
asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents.
517 12/02 Revised © 2002 ADC Telecommunications, Inc.
All Rights Reserved
An Equal Opportunity Employer
64