xStart: Efficient solutions for motor control Product information DIL M motor contactors

xStart: Efficient solutions for motor control Product information DIL M motor contactors
xStart: Efficient solutions
for motor control
The complete range of contactors, efficient motor-starters
and variable speed drives for
the motor circuit. New simple
to install solutions based on
clever communication.
DIL contactors
Product information
DIL M motor contactors
PKZ motor-protective
circuit-breakers
MSC motor-starters
PKZ motor-protective circuit-breakers
MSC motor-starters
DS 4 softstarters
DF & DV Drives
Rapid Link
A
Think future. Switch to green.
xStart is the intelligent solution:
easier engineering, faster fitting
1
2
“We need a partner we can rely on.
Moeller satisfies all of our needs.“
Both trade and industry expect innovations in
electrical engineering to bring them clear
advantages by making processes more efficient
– all the way from the planning stage through
engineering to fitting and installation. The new
xStart range from Moeller does just that.
With Moeller you can meet any
challenge!
Moeller has proved its competence as
a partner with high-quality, efficient
motor-related solutions for more than
a century. xStart now offers you the
complete range of products needed for
switching, protecting, starting, running
up and controlling motors. You can rely
on our competence in each of these
areas, and we can meet any challenge
from contactors to drive control.
1
The latest innovation is the new
MSC motor-starter: a combination
of standard components, i.e. the
new DIL M motor contactors and
the optimised PKZ motor-protective circuit-breakers.
Just four slim starter modules up
to 150 A, each with the same
dimensions for AC and DC, significantly simplify planning and
engineering.
2
The newly developed DIL M
motor contactors can switch
motors up to 150 A. Their significantly improved performance
criteria such as pick-up and
sealing consumption, space
saving foot-prints and ease of
installation make these contactors state-of-the-art, top-class
products.
Tested quality
Every single one of our products is built
and tested to the latest national and
international standards. Having attained
all the major approvals, they are perfectly
suited to the world's markets.
2
3
PKZ motor-protective
circuit-breakers:
now better than ever
PKZ motor-protective
circuit-breakers from
Moeller have long set
the benchmark for
quality. And now, for
inclusion in the xStart
concept, these products have been updated once again, and
enhanced in terms of
their technical specification.
The PKZM 0 now switches motors up
to 32 A. At the same time, its shortcircuit switching capacity is significantly
increased: the short-circuit rating
(400 V) is now 150 kA up to 12 A and
50 kA up to 32 A. The PKZM 4 also has
a switching capacity of 50 kA. This simplifies the engineering of safety and
reliability, with current limiters becoming
virtually obsolete. PKZM 01 is a completely new product with push-button
operation for switching motors up to
16 A (50 kA/400 V).
“PKZ motor-protective circuit-breakers
are, and always will be, the epitome
of safety, reliability and quality in
motor protection.“
4
1
2
3
5
6
45 mm
55 mm
4
Common accessories throughout the
system
Whether PKZM 0, PKZM 01 or PKZM 4,
the accessories are always the same.
Whether On or Off, overload or short
circuit, differential indication helps to
locate the cause of tripping without
delay, every time. The auxiliary contacts
can be fitted without tools and are failsafe in the way they signal every switching state. One particularly convenient
component is the NHI-E front auxiliary
contact that can be optionally built into
already installed and wired circuitbreakers. It goes without saying that all
the auxiliary contacts and releases are
worldmarket devices, for all the customary mains voltages.
1
Shunt trips and undervoltage
trips
2
PKZM 0 motor-protective circuitbreakers from 0 to 32 A
3
PKZM 4 motor-protective circuitbreakers from 10 to 65 A
4
The optionally integrable front
auxiliary contact indicates the
switching position of 1 NO and
NC contact or 1 NO contact
5
Trip-indicating contacts: two contacts provide differential indication
of short circuit or overload
6
Standard auxiliary contacts with
up to three contacts for the
On/Off switching position
The door coupling handle (IP 65) has a
tripped position in addition to the On
and Off positions.
PKZM 01 motor-protective circuitbreakers: easy to operate by pressing
or hitting a button
The new PKZM 01 motor-protective
circuit-breakers for motors up to 12 A
are ideally suited to small machines and
applications where operation by pressing
or even hitting a button is preferred. In
addition to the auxiliary contacts from
the PKZM 0 range, special enclosures
with ingress protection IP 65 or IP 40 and
the appropriate Emergency-Stop buttons
are available for these new components.
Their short-circuit switching capacity is
50 kA.
5
AC and DC contactors:
both the same frame size –
simplifies engineering
Great efficiency in
planning and engineering with AC and
DC contactors is
achieved by them
being the same dimensions. With only four
component sizes
covering the rating
range up to 150 A
engineering is further
simplified.
Definitely useful: up to 32 A, the auxiliary
contact is already built in, and the DC
contactors include a suppressor circuit up
to 150 A. From 12 A, the DC contactors
have an electronic drive that removes
the need for coupling relays. With all
these extras already included in the contactors, your costs are clearly reduced.
DC
DC
AC
DC contactors now are no bigger
than AC contactors
The new DIL contactors are significantly
more compact than their predecessors,
even though, up to 32 A, the auxiliary
contact is included. The advantage of
this is particularly striking with the DC
contactors that now are the same size
as their AC counterparts. This makes
everything easier, i.e. planning, engineering and fitting, without having to
alter the control system, even if the control current has to change for another
customer.
6
a sealing consumption of only 0.5 Watt,
even those at 150 A only use 1.5 Watt.
This also results in lower power consumption for the whole installation.
2
“With these new motor contactors,
Moeller is definitely on to a winner.
They bring real advantages from the
planning all the way to the fitting
costs.”
1
This reduces the cost of your
control panel
The space-saving is achieved not just by
the reduced component dimensions,
but also due to the lower heat dissipation that, particularly with the DC contactors, helps keep the cabinet size
down and saves the cost of a fan. The
significantly reduced sealing consumption achieved by innovative, electronic
drives makes this possible. The Moeller
DC contactors from 17 up to 65 A have
No compromise where termination reliability is concerned
DIL contactors up to 150 A have box
terminals with two clamping chambers,
allowing unequal cable cross-sections
to be terminated absolutely securely,
even in strongly vibrating machines.
This makes wiring easier and cuts down
on associated errors.
3
1
The benefits of the electronically controlled drive
All DC DIL M motor contactors from
12 A have an electronically controlled
drive that offers the following advantages:
2
• Significantly less heat dissipation due
to reduced sealing consumption
• Smaller control transformers because
of lower pick-up consumption
• Direct actuation from the PLC without
coupling contactors.
3
4
5
4
The new DIL A auxiliary contacts
perfectly complement the new
DIL M motor contactors.
5
Z overloads relays protect the
motor against phase failure or
overload. Their auxiliary contacts
switch the motor contactor off,
and signal the fault. These relays
are suitable for protecting EEx
e-motors according to ATEX 100 a
guideline.
7
The simplicity of it! –
Toolless plug connection!
8
Using the new xStart
motor-starter combinations it is possible to
create the best solutions from standard
products even more
easily and efficiently.
Moeller has optimised the DIL and PKZ
standard products in such a way that,
by using simple toolless plug connectors,
they can be assembled to form reliable
motor-starters. Without the need for
tools! The MSC motor-starter combinations can also be supplied as complete
devices. Costs for fitting and wiring can
be considerably reduced in this way.
Costs for testing are cut and errors are
prevented from the start. Another advantage lies in increased safety during
maintenance work where removal of
the combination plug connector produces a visible isolating gap. This Moeller
technology is available on our direct-online and reversing starters up to 12 A.
Slim solutions: DOL starters from
standard components
The new direct-on-line starters built
from standard components are available
in four slim frame sizes. The contactor
and the protective switch are of the
same compact width dimension. Thus
you lose not a millimetre of control panel
space. The convenient MSC motorstarters using toolless plug connection
technology are available up to 12 A and
require only a top-hat rail for mounting.
The mechanical connector ensures a
secure hold and the electrical connector
provides optimum reliability and safety.
Complete mounting connectors are
offered for DOL and reversing starters
from 17 up to 32 A. This prevents fitting
errors and cuts down on wiring time.
Plug and go: reversing starters from
standard components
The reversing starters offer distinct advantages to the assembler. Instead of
laboriously having to tighten up 23
screws, a small number of components
simply plug together. This of course
speeds up fitting work, and means fewer
errors and a very clearly laid out
switching installation.
Speedier wiring using spring-loaded
terminations
“The toolless plug connection is
very quick to fit – just what I need
to reduce costs.”
Moeller provides proven quality with
tension clamp terminals. Numerous
tests have proved that contactors and
motor-protective circuit-breakers are
just as securely wired in this way as by
screw connection – even in strongly
vibrating machines. But wiring work
using tension clamp terminals is very
much quicker to do. The main current
paths on PKZM 0 and motor contactors
up to 12 A all use spring-loaded terminals. The sundries for termination are
always available for both screw and
tension clamp connection.
9
E-Mail: [email protected]
Internet: www.moeller.net
© 2004 by Moeller GmbH
Subject to change
W1200+2100-7548 GB
Printed in the Federal Republic of Germany (04/04)
Article No.: 284765
Xtra Combinations
Xtra Combinations from Moeller offers a range of
products and services, enabling the best possible
combination options for switching, protection and
control in power distribution and automation.
Using Xtra Combinations enables you to find
more efficient solutions for your tasks while optimising the economic viability of your machines
and systems.
It provides:
■ flexibility and simplicity
■ great system availability
■ the highest level of safety
All the products can be easily combined with one
another mechanically, electrically and digitally,
enabling you to arrive at flexible and stylish solutions tailored to your application – quickly, efficiently and cost-effectively. The products are proven
and of such excellent quality that they ensure a
high level of operational continuity, allowing you
to achieve optimum safety for your personnel,
machinery, installations and buildings.
Thanks to our state-of-the-art logistics operation,
our comprehensive dealer network and our highly
motivated service personnel in 80 countries around
the world, you can count on Moeller and our products every time. Challenge us! We are looking
forward to it!
A
Think future. Switch to green.
PKZ
motor-protective circuit-breaker
1
5
2
6
4
7
3
1.
2.
3.
4.
5.
6.
7.
10
PKZM01 motor-protective circuit-breaker
PKZM0 motor-protective circuit-breaker
PKZM4 motor-protective circuit-breaker
Door coupling rotary handle IP65
Voltage release
Trip-indicating auxiliary contact
Auxiliary contacts
7
PKZM0, PKZM4 motor-protective circuit-breakers
Max. motor rating
Rated uninterrupted
Setting range
Screw terminals
current
Overload releases
Short-circuit release
Type
380 V 400 V 415 V
Iu
Ir
Irm
Article no.
P
A
A
A
–
0.16
0.1 – 0.16
2.2
PKZM0-0,16
072730
0.06
0.25
0.16 – 0.25
3.5
PKZM0-0,25
072731
0.09
0.4
0.25 – 0.4
5.6
PKZM0-0,4
072732
0.12
0.63
0.4 – 0.63
8.8
PKZM0-0,63
072733
0.25
1
0.63 – 1
14
PKZM0-1
072734
0.55
1.6
1 – 1.6
22
PKZM0-1,6
072735
0.75
2.5
1.6 – 2.5
35
PKZM0-2,5
072736
1.5
4
2.5 – 4
56
PKZM0-4
072737
2.2
6.3
4 – 6.3
88
PKZM0-6,3
072738
4
10
6.3 – 10
140
PKZM0-10
072739
5.5
12
9 – 12
168
PKZM0-12
278486
7.5
16
10 – 16
224
PKZM0-16
046938
9
20
16 – 20
280
PKZM0-20
046988
12.5
25
20 – 25
350
PKZM0-25
046989
15
32
25 – 32
448
PKZM0-32
278489
7.5
16
10 – 16
224
PKZM4-16
222350
12.5
25
16 – 25
350
PKZM4-25
222352
15
32
25 – 32
448
PKZM4-32
222353
20
40
32 – 40
560
PKZM4-40
222354
25
50
40 – 50
700
PKZM4-50
222355
30
58
50 – 58
812
PKZM4-58
222394
34
65
55 – 63
882
PKZM4-63
222413
AC-3
kW
Motor-protective circuit-breakers,
classification type “1” and “2”
Motor-protective circuit-breaker,
classification type “1” and “2”
Note
Three-phase motors (approximate values for squirrel-cage rotors)
11
PKZM01 motor-protective circuit-breaker
Max. motor rating
Rated uninterrupted
current
Setting range
Overload releases
Short-circuit releases
380 V 400 V 415 V
Iu
Ir
Irm
P
kW
A
A
A
–
0.16
0.1 – 0.16
2.2
PKZM01-0,16
278475
0.06
0.25
0.16 – 0.25
3.5
PKZM01-0,25
278476
0.09
0.4
0.25 – 0.4
5.6
PKZM01-0,4
278477
0.12
0.63
0.4 – 0.63
8.8
PKZM01-0,63
278478
0.25
1
0.63 – 1
14
PKZM01-1
278479
0.55
1.6
1 – 1.6
22
PKZM01-1,6
278480
0.75
2.5
1.6 – 2.5
35
PKZM01-2,5
278481
1.5
4
2.5 – 4
56
PKZM01-4
278482
2.2
6.3
4 – 6.3
88
PKZM01-6,3
278483
4
10
6.3 – 10
140
PKZM01-10
278484
5.5
12
8 – 12
168
PKZM01-12
278485
7.5
16
10 – 16
224
PKZM01-16
283390
AC-3
Motor-protective circuit-breakers,
classification type “1” and “2”
Note
Screw terminals
Type
Article no.
Three-phase motors (approximate values for squirrel-cage rotors)
Insulated enclosures
Insulated enclosures for
surface mounting
Insulated enclosures for flush mounting
12
Protection
type
For use with
Type
Article no.
–
IP40
PKZM01+NHI-E or VHI-PKZ01+U or A
or NHI+L (2 off)
CI-PKZ01
281403
With actuating diaphragm
IP65
PKZM01+NHI-E or VHI-PKZ01+U or A
or NHI+L (2 off)
CI-PKZ01-G
281404
Lockable in the Off position
IP65
PKZM01+NHI-E+U or A (undervoltage
or shunt release)+L (2 off)
CI-PKZ01-SVB
281405
Lockable in the Off position,
in conjunction with VHI-PKZ01
IP65
PKZM01+NHI-E or VHI-PKZ01+U or A
CI-PKZ01-SVB-V
(undervoltage or shunt release)+L (2 off) 281944
With stay-put Emergency-Stop
mushroom button
IP65
PKZM01+NHI-E or VHI-PKZ01+U or A
CI-PKZ01-PVT
(undervoltage or shunt release)+L (2 off) 281406
With key-release Emergency-Stop
mushroom button
IP65
PKZM01+NHI-E or VHI-PKZ01+U or A
CI-PKZ01-PVS
(undervoltage or shunt release)+L (2 off) 281407
–
Front IP40
PKZM01+NHI-E or VHI-PKZ01+U or A
or NHI+L (2 off)
E-PKZ01
281633
With actuating diaphragm
Front IP55
PKZM01+NHI-E or VHI-PKZ01+U or A
or NHI+L (2 off)
E-PKZ01-G
281634
Lockable in the Off position
Front IP55
PKZM01+NHI-E or VHI-PKZ01+U or A
E-PKZ01-SVB
(undervoltage or shunt release)+L (2 off) 281635
Lockable in the Off position,
in conjunction with VHI-PKZ01
Front IP55
PKZM01+NHI-E or VHI-PKZ01+U or A
E-PKZ01-SVB-V
(undervoltage or shunt release)+L (2 off) 281943
With stay-put Emergency-Stop
mushroom button
Front IP55
PKZM01+NHI-E or VHI-PKZ01+U or A
E-PKZ01-PVT
(undervoltage or shunt release)+L (2 off) 281636
With key-release Emergency-Stop
mushroom button
Front IP55
PKZM01+NHI-E or VHI-PKZ01+U or A
E-PKZ01-PVS
(undervoltage or shunt release)+L (2 off) 281637
Accessories
Contacts
M = Make
Type of current AC/DC
For use with
B = Break
Type
Article no.
when ordered separately
Trip-indicating auxiliary contact 2 x 1 M
–
–
PKZM0
PKZM4
Early-make auxiliary contacts
–
2x1B
–
2M
–
–
AGM2-10-PKZ0
072898
PKZM01
AGM2-01-PKZ0
072899
PKZM0
VHI20-PKZ0
203595
PKZM01
–
2M
–
–
PKZM01
VHI20-PKZ01
278495
Shunt release
–
–
AC operation
PKZM0
A-PKZ0(230V50HZ)
073187
–
–
DC operation
PKZM01
A-PKZ0(24VDC)
073200
–
–
AC operation
PKZM0
U-PKZ0(230V50HZ)
073135
PKZM4
Undervoltage release
PKZM4
PKZM01
Standard auxiliary contact
1M
1B
–
PKZM0
PKZM4
Standard auxiliary contact
NHI11-PKZ0
072896
1M
2B
–
2M
1B
–
NHI21-PKZ0
072894
1M
1B
–
NHI-E-11-PKZ0
082882
1M
–
–
NHI-E-10-PKZ0
082884
PKZM01
NHI12-PKZ0
072895
13
Technical data basic units
PKZM01...
PKZM0-...
PKZM4
°C
–25/55
–25/55
–25/55
Solid
mm2
1 x (1 – 6)
2 x (1 – 6)
1 x (1 – 6)
2 x (1 – 6)
1 x (1 – 50)
2 x (1 – 35)
Flexible with ferrule
mm2
1 x (1 – 6)
2 x (1 – 6)
1 x (1 – 6)
2 x (1 – 6)
1 x (1 – 35)
2 x (1 – 35)
Solid or stranded
AWG
18 – 10
18 – 10
14 – 2
Main contacts
Nm
1.7
1.7
3
Auxiliary contacts
Nm
1
1
1
General
Ambient temperature
open
Terminal capacity
Tightening torque, terminal screws
Main contacts
Rated operational voltage
Ue
V AC
690
690
690
Rated uninterrupted current =
rated operational current
Iu = Ie
A
16 or setting current of
overcurrent release
32 or setting current of
overcurrent release
63 or setting current of
overcurrent release
Lifespan, mechanical
Operations
x 106
0.05
0.05
0.03
Lifespan, electric (AC-3 at 400 V)
Operations
x 106
0.05
0.05
0.03
Ops/h
25
40
40
to IEC/EN 60947, VDE 0660
°C
–5/40
–5/40
–5/40
Operating range
°C
–25/55
–25/55
–25/55
Setting range, overload release
x Iu
0.6 – 1
0.6 – 1
0.6 – 1
Short-circuit release fixed
x Iu
14
14
14
IEC/EN 60947-4-1,
VDE 0660 Part 102
IEC/EN 60947-4-1,
VDE 0660 Part 102
IEC/EN 60947-4-1,
VDE 0660 Part 102
Maximum operating frequency
Releases
Temperature compensation
Phase-failure sensitivity
Technical data auxiliary contacts
NHI...PKZ0
NHI-E-...PKZ0
VHI...PKZ0
AGM
Terminal capacity
14
Solid or flexible with ferrule
mm2
0.75 – 2.5
0.75 – 1.5
0.75 – 1.5
0.75 – 2.5
Solid or stranded
AWG
18 – 14
18 – 16
18 – 16
18 – 14
PKZM, dimensions
Motor-protective circuit-breakers
Motor-protective circuit-breaker with early-make auxiliary contact
PKZM0-…(+NHI-E-..-PKZ0)
PKZM0-…+VHI-…-PKZ0
80
45
55
93
93
45
55
4.5
70
VHI...-PKZ0
NHI-E-..-PKZ0
NHI-E-..-PKZ0
VHI...-PKZ0
50
25
68
76
45
50
45
68
AGM2-…-PKZ0
U/A-PKZ0
9
26
68
90
45
90
45
26
9
18
68
90
NHI…-PKZ0
36
Voltage release
36
Trip-indicating auxiliary contact
36
Standard auxiliary contact
45
86
49
68
Motor-protective circuit-breakers
45
93
PKZM01
45
5.5
44
74
85
Switching capacity with classification type “1” and “2”
PKZM0
PKZM01
Iu
A
400 V
Iq
kA
Icu
kA
Ics
kA
0.16 – 1
1.6
2.5
4
6.3
10
12
16
20
25
32
150
150
150
150
150
150
50
50
50
50
50
150
150
150
150
150
150
50
50
50
50
50
150
150
150
150
150
150
10
10
10
10
10
A1)
400 V
Iq
kA
Icu
kA
Ics
kA
A2)
N
N
N
N
N
N
50
50
50
50
50
50
50
50
50
50
50
50
–
–
–
–
50
50
50
50
50
50
50
–
–
–
–
50
50
50
50
50
50
10
–
–
–
–
50
50
50
50
50
50
50
–
–
–
–
Rated uninterrupted current Iu
Rated conditional short-circuit current Iq IEC/EN 60947-4-1
Rated ultimate short-circuit breaking capacity Icu !
" IEC/EN 60439-2
Rated breaking capacity Ics
#
1)
Required back-up fuse, if the short-circuit current
exceeds the rated conditional short-circuit current of the devices (Icc ⬎ Iq).
2)
Fuse (A gG/gL) to raise the switching capacity of the motor-protective
circuit-breaker to 100 kA
N
Not required
No upstream protective device necessary,
since inherently protected range (100/150 kA)
15
Contactors DILM7 – 65
DILA contactor relays
DILM40 – DILM65
DILM17 – DILM32
DILM7 – DILM12
1
1
1
5
2
2
5
4
3
3
1.
2.
3.
4.
5.
Basic units
Suppressor 1)
Auxiliary contact modules, 2-pole
Auxiliary contact modules, 4-pole
Overload relays
1) For AC operated contactors 50 – 60 Hz;
in DC operated contactors, the suppressor circuit is incorporated.
Note drop-out delay
16
4
DILM basic units
AC-3
AC-3
open
Contacts
380 V 380 V Ith =
400 V 400 V Ie
A
B = Break
M = Make
7
3
20
1M
–
7
3
–
9
4
9
DC actuation
Type
Article no.
24 V 50/60 Hz
Type
Article no.
110 V 50 Hz,
120 V 60 Hz
Type
Article no.
DILM32-XHI..
DILA-XHI(V)..
DILM7-10(...)
276550
DILM7-10(...)
276554
DILM7-10(...)
276547
DILM7-10(24VDC)
276565
1B
DILA-XHI(V)..
DILM7-01(...)
276585
DILM7-01(...)
276589
DILM7-01(...)
276582
DILM7-01(24VDC)
276600
1M
–
DILM32-XHI..
DILA-XHI(V)..
DILM9-10(...)
276690
DILM9-10(...)
276694
DILM9-10(...)
276687
DILM9-10(24VDC)
276705
4
–
1B
DILA-XHI(V)..
DILM9-01(...)
276725
DILM9-01(...)
276729
DILM9-01(...)
276722
DILM9-01(24VDC)
276740
12
5.5
1M
–
DILM32-XHI..
DILA-XHI(V)..
DILM12-10(...)
276830
DILM12-10(...)
276834
DILM12-10(...)
276827
DILM12-10(24VDC)
276845
12
5.5
–
1B
DILA-XHI(V)..
DILM12-01(...)
276865
DILM12-01(...)
276869
DILM12-01(...)
276862
DILM12-01(24VDC)
276880
4-pole
–
–
DILMP20(...)
276970
DILMP20(...)
276974
DILMP20(...)
276967
DILMP20(24VDC)
276985
3-pole
18
7.5
35
1M
–
DILM32-XHI..
DILA-XHI(V)..
DILM17-10(...)
277004
DILM17-10(...)
277008
DILM17-10(...)
277001
DILM17-10(RDC24)
277018
18
7.5
35
–
1B
DILA-XHI(V)..
DILM17-01(...)
277036
DILM17-01(...)
277040
DILM17-01(...)
277033
DILM17-01(RDC24)
277050
25
11
40
1M
–
DILM32-XHI..
DILA-XHI(V)..
DILM25-10(...)
277132
DILM25-10(...)
277136
DILM25-10(...)
277129
DILM25-10(RDC24)
277146
25
11
40
–
1B
DILA-XHI(V)..
DILM25-01(...)
277164
DILM25-01(...)
277168
DILM25-01(...)
277161
DILM25-01(RDC24)
277178
32
15
40
1M
–
DILM32-XHI..
DILA-XHI(V)..
DILM32-10(...)
277260
DILM32-10(...)
277264
DILM32-10(...)
277257
DILM32-10(RDC24)
277274
32
15
40
–
1B
DILA-XHI(V)..
DILM32-01(...)
277292
DILM32-01(...)
277296
DILM32-01(...)
277289
DILM32-01(RDC24)
277306
40
18.5
50
–
–
DILM150-XHI(V)..
DILM1000-XHI(V)..
DILM40(...)
277766
DILM40(...)
277770
DILM40(...)
277763
DILM40(RDC24)
277780
50
22
60
–
–
DILM150-XHI(V)..
DILM1000-XHI(V)..
DILM50(...)
277830
DILM50(...)
277834
DILM50(...)
277827
DILM50(RDC24)
277844
65
30
72
–
–
DILM150-XHI(V)..
DILM1000-XHI(V)..
DILM65(...)
277894
DILM65(...)
277898
DILM65(...)
277891
DILM65(RDC24)
277908
1)
P
kW
AC operation
Type
Article no.
230 V 50Hz
3-pole
Ie
A
Can be combined
with auxiliary
contact
–
–
DILM32-XHI..
DILA-XHI(V)..
The listed auxiliary and main contacts up to 12 A are available with tension clamp
terminations.
The auxiliary contact modules listed for the DILA contactor relay can also be used for the
DILM contactors up to 32 A.
Auxiliary contact members: DILA-XHI to EN 50005, DILM32-XHI to DIN 50012
The 2- and 4-pole DILM32-XHI... auxiliary contact modules can not be combined with
DILM...-01 contactors.
1) Availability
for supply for DILM40 to DILM65 from December 2004.
17
Auxiliary contact modules
Ith = Ie
Contacts
Ie
open
AC–15
A
M = Make
B = Break
MF = Early-make contacts
BS = Late-break contacts
10
1M
1B
3
–
2B
4-pole
2M
2B
2-pole
2M
–
1M
1B
–
2B
1 MF
1 BS
DILA-XHIV11
276423
4M
–
DILA-XHI40
276428
3M
1B
DILA-XHI31
276427
2M
2B
DILA-XHI22
276426
1M
3B
DILA-XHI13
276425
–
4B
DILA-XHI04
276424
1 MF
1 BS
DILA-XHIV22
276429
2
–
1
1
–
2
DILM150-XHI02
277947
4
–
DILM150-XHI40
277948
3
1
DILM150-XHI31
277949
2
2
DILM150-XHI22
277950
1
3
DILM150-XHI13
277951
–
4
DILM150-XHI04
277952
1 M, 1 MF
1 B, 1 BS
DILM150-XHIV22
277953
1
1
2-pole
4-pole
2-pole
10
4-pole
–
2-pole
10
Can be combined
with basic unit
Type
DILM7-10...
DILM9-10...
DILM12-10...
DILM17-10...
DILM25-10...
DILM32-10...
DILM32-XHI11
277376
DILM7...
DILM9...
DILM12...
DILM17...
DILM25...
DILM32...
DILA-XHI20
276422
A
3
3
DILM40...
DILM50...
DILM65...
DILM40...
DILM50...
DILM65...
The listed auxiliary and main contacts up to 12 A are available with tension clamp terminations.
The auxiliary contact modules listed for the DILA contactor relay can also be used for the DILM contactors up to 32 A.
Auxiliary contact members: DILA-XHI to EN 50005, DILM32-XHI to DIN 50012
The 2- and 4-pole DILM32-XHI... auxiliary contact modules can not be combined with DILM...-01 contactors.
1) NEW:
Also available as 4-pole version DILM150-XHIA22 with terminal markings 53/54, 61/62, 71/72 and 83/84
(Article no. 283464) in order to avoid duplication of terminal markings on combinations with auxiliary contact on the side.
18
Article no.
380 V 400 V 415 V
DILM32-XHI02
277375
DILM32-XHI22
277377
DILA-XHI11
276421
DILA-XHI02
276420
DILM150-XHI20
277945
DILM150-XHI11
277946
DILM1000-XHI11-SI
278425
DILM150-XHIA111)
283463
Accessories
Suppressor
Varistor suppressor
Us
V AC
For use with
24 – 48
DILM7 – DILM12
48 – 130
Contact sequence
A1
DILMP20
DILA
A2
240 – 500
DILM17 – DILM32
48 – 130
130 – 240
240 – 500
24 – 48
DILM40 – DILM65
48 – 130
130 – 240
240 – 500
Varistor suppressors with
built-in LED
24 – 48
127 – 240
24 – 48
DILM7 – DILM12
DILMP20
A1
DILA
A2
DILM17 – DILM32
130 – 240
24 – 48
DILM40 – DILM65
130 – 240
RC suppressor
24 – 48
130 – 240
DILM7 – DILM12
A1
DILMP20
DILA
A2
240 – 500
24 – 48
DILM17 – DILM32
110 – 240
240 – 500
24 – 48
DILM40 – DILM65
110 – 240
240 – 500
Connector
–
For the mechanical
connection of contactors to
groups of components
Mechanical interlock
DILM7 – DILM32
–
DILA
DILM40 – DILM65
–
Notes
Article no.
130 – 240
24 – 48
Type
DILM7 – DILM32
DILMP20
DILA
DILM17 – DILM32
DILM40 – DILM65
–
DILM12-XSPV48
281208
DILM12-XSPV130
281209
DILM12-XSPV240
281210
DILM12-XSPV500
281211
DILM32-XSPV48
281212
DILM32-XSPV130
281213
DILM32-XSPV240
281214
DILM32-XSPV500
281215
DILM95-XSPV48
281216
DILM95-XSPV130
281217
DILM95-XSPV240
281218
DILM95-XSPV500
281219
DILM12-XSPVL48
281220
DILM12-XSPVL240
281221
DILM32-XSPVL48
281222
DILM32-XSPVL240
281223
DILM95-XSPVL48
281224
DILM95-XSPVL240
281225
DILM12-XSPR48
281199
DILM12-XSPR240
281200
DILM12-XSPR500
281201
DILM32-XSPR48
281202
DILM32-XSPR240
281203
DILM32-XSPR500
281204
DILM95-XSPR48
281205
DILM95-XSPR240
281206
DILM95-XSPR500
281207
DILM32-XVB
281227
DILM150-XVB
281226
DILM12-XMV
281196
DILM32-XMV
281197
DILM65-XMV
281198
For AC operated contactors, 50-60 Hz
DC operated contactors have an
integrated suppressor
Note drop-out delay
Availability for supply for
DILM95-XSPV48/130/240/500 from
December 2004
For AC operated contactors, 50-60 Hz
DC operated contactors have an
integrated suppressor
Note drop-out delay
Availability for supply for
DILM95-XSPVL48/240
from December 2004
For AC operated contactors, 50-60 Hz
DC operated contactors have an
integrated suppressor
Note drop-out delay
Availability for supply for
DILM95-XSPR48/240/500
from December 2004
0 mm distance between contactors
Availability for supply for
DILM150-XVB from December 2004
For two contactors with AC or DC
operation, distance between
contactors 0 mm, mechanical
lifespan 2.5 X 10 6 switching
operations, additional auxiliary
contact modules can be fitted
Availability for supply for
DILM65-XMV from December 2004
19
Technical data
DILM7
DILM9
DILM12
General
Lifespan, mechanical
AC operated
Operations
x 106
10
10
10
DC operated
Operations
x 106
10
10
10
open
°C
–25/60
–25/60
–25/60
Main contacts
Make contact
g
10
10
10
Auxiliary contacts
Make contact
g
7
7
7
Break
g
5
5
5
AC operated
kg
0.23
0.23
0.23
DC operated
kg
0.28
0.28
0.28
mm2
1 x (0.75 – 4)
1 x (0.75 – 4)
1 x (0.75 – 4)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
1 x (0.75 – 4)
1 x (0.75 – 4)
1 x (0.75 – 4)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
Ambient temperature
Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
contact
Weight
Terminal capacity, main contacts
Solid
mm2
Flexible with ferrule
Stranded
mm2
–
–
–
Solid or stranded
AWG
18 – 14
18 – 14
18 – 14
mm
–
–
–
Solid
mm2
1 x (0.75 – 4)
1 x (0.75 – 4)
1 x (0.75 – 4)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
Flexible with ferrule
mm2
1 x (0.75 – 2.5)
1 x (0.75 – 2.5)
1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
Solid or stranded
AWG
18 – 14
18 – 14
18 – 14
Ui
V AC
690
690
690
Ue
V AC
690
690
690
A
108
108
144
220/230 V
A
70
90
120
380/400 V
A
70
90
120
500 V AC
A
50
70
100
660/690 V
A
40
50
70
1000 V
A
–
–
–
Flat conductor
Number of layers
x width
x thickness
Terminal capacity, auxiliary contacts
Main contacts
Rated insulation voltage
AC
Rated operational voltage
Making capacity (cos v to IEC/EN 60947)
Breaking capacity
Component lifespan
AC-3
AC-4
20
Operations
x 106
1.3
1.3
1.3
Operations
106
0.2
0.2
0.2
x
Technical data
DILM17
DILM25
DILM32
DILM40
DILM50
DILM65
10
10
10
10
10
10
10
10
10
10
10
10
–25/60
–25/60
–25/60
–25/60
–25/60
–25/60
10
10
10
10
10
10
7
7
7
7
7
7
5
5
5
5
5
5
0.4
0.4
0.4
0.9
0.9
0.9
0.4
0.4
0.4
0.9
0.9
0.9
1 x (0.75 – 16)
1 x (0.75 – 16)
1 x (0.75 – 16)
1 x (2.5 – 16)
1 x (2.5 – 16)
1 x (2.5 – 16)
2 x (0.75 – 10)
2 x (0.75 – 10)
2 x (0.75 – 10)
2 x (2.5 – 16)
2 x (2.5 – 16)
2 x (2.5 – 16)
1 x (0.75 – 16)
1 x (0.75 – 16)
1 x (0.75 – 16)
1 x (2.5 – 35)
1 x (2.5 – 35)
1 x (2.5 – 35)
2 x (0.75 – 10)
2 x (0.75 – 10)
2 x (0.75 – 10)
2 x (2.5 – 25)
2 x (2.5 – 25)
2 x (2.5 – 25)
1 x 16
1 x 16
1 x 16
1 x (16 – 50)
1 x (16 – 50)
1 x (16 – 50)
2 x (16 – 35)
2 x (16 – 35)
2 x (16 – 35)
14 – 6
14 – 6
14 – 6
12 – 2
12 – 2
12 – 2
–
–
–
2 x (6 x 9 x 0.8)
2 x (6 x 9 x 0.8)
2 x (6 x 9 x 0.8)
1 x (0.75 – 4)
1 x (0.75 – 4)
1 x (0.75 – 4)
1 x (0.75 – 4)
1 x (0.75 – 4)
1 x (0.75 – 4)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
1 x (0.75 – 2.5)
1 x (0.75 – 2.5)
1 x (0.75 – 2.5)
1 x (0.75 – 2.5)
1 x (0.75 – 2.5)
1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
2 x (0.75 – 2.5)
18 – 14
18 – 14
18 – 14
18 – 14
18 – 14
18 – 14
690
690
690
690
690
690
690
690
690
690
690
690
238
350
448
560
700
910
170
250
320
400
500
650
170
250
320
400
500
650
170
250
320
400
500
650
120
150
180
250
320
370
–
–
–
–
–
–
1.3
1.3
1.3
1.3
1.3
1.3
0.2
0.2
0.2
0.2
0.2
0.2
21
Technical data
DILM7
DILM9
DILM12
AC
AC-1 actuation
Conventional free air
Open
thermal current,
At 40 °C
A
22
22
22
At 60 °C
A
20
20
20
3-pole 50/60 Hz
AC-3 actuation
Rated operational current, AC-3
220/230 V
Ie
A
7
9
12
open, 50/60 Hz, 3-pole
380/400 V
Ie
A
7
9
12
500 V
Ie
A
5
7
10
660/690 V
Ie
A
4
5
7
220/230 V
P
kW
2.2
2.5
3.5
380/400 V
P
kW
3
4
5.5
500 V
P
kW
3.5
4.5
7
660/690 V
P
kW
3.5
4.5
6.5
AC operated
Pick-up
x Uc
0.8 – 1.1
0.8 – 1.1
0.8 – 1.1
DC operated
Pick-up
x Uc
0.8 – 1.1
0.8 – 1.1
0.8 – 1.1
Pick-up
VA
28
26
28
26
28
26
W
22
21
22
21
22
21
VA
4.6
3.9
4.6
3.9
4.6
3.9
W
1.4
1.2
1.4
1.2
1.4
1.2
Pick-up
W
3
3
4.5
Sealing
W
3
3
4.5
Motor rating
Magnet systems
Pick-up and drop-out values
Coil consumption from cold and 1.0 x Uc
AC operated 50/60 Hz
Sealing
DC operated
Dimensions
DILM7 – DILM12, DILA with auxiliary contact module
DILM17 – DILM32 basic unit
8.7 8.7 8.7 8.7
45
(5.1)
4.5
6.5
4.8
17.7
75
125.2
(6.4)
11.6 11.6 10.6
45
22
71
85
38
3.2
60.4
68
45
18
36
Technical data
DILM17
DILM25
DILM32
DILM40
DILM50
DILM65
40
45
45
60
70
85
35
36
36
50
60
72
17
25
32
40
50
65
18
32
25
40
50
65
17
25
32
40
50
65
12
15
18
25
32
37
5
10
7.5
12.5
15.5
20
7.5
15
11
18.5
22
30
12
23
17.5
28
36
47
11
17
14
23
30
35
0.8 – 1.1
0.8 – 1.1
0.8 – 1.1
0.8 – 1.1
0.8 – 1.1
0.8 – 1.1
0.7 – 1.2
0.7 – 1.2
0.7 – 1.2
0.7 – 1.2
0.7 – 1.2
0.7 – 1.2
60
54
60
54
60
54
–
–
–
48
43
48
43
48
43
–
–
–
9.5
7.9
9.5
7.9
9.5
7.9
–
–
–
2.8
2.4
2.8
2.4
2.8
2.4
–
–
–
12 at 24 V
12 at 24 V
12 at 24 V
24 at 24 V
24 at 24 V
24 at 24 V
0.5 at 24 V
0.5 at 24 V
0.5 at 24 V
0.5 at 24 V
0.5 at 24 V
0.5 at 24 V
Dimensions
104
57
86.4
DILM40 – DILM65 basic unit
4.5
6.5
34.4
97.4
147.3
55
4.7
6.9
113.8
132.1
146.75
23
DILA contactor relays
Contacts
AC–15
Can be combined
with auxiliary
contact
380 V
400 V
415 V
M = Make
B = Break
Basic units with
interlocked
opposing contacts
Ie
Ith
A
A
AC operation
DC operation
Type
Type
Type
Type
Article no.
Article no.
Article no.
Article no.
230 V 50 Hz
24 V 50/60 Hz
110 V 50 Hz,
120 V 60 Hz
24 V DC
4M
–
4
10
DILA-XHI(V)...
DILA-40(...)
276329
DILA-40(...)
276333
DILA-40(...)
276326
DILA-40(...)
276344
3M
1B
4
10
DILA-XHI(V)...
DILA-31(...)
276364
DILA-31(...)
276368
DILA-31(...)
276361
DILA-31(...)
276379
2M
2B
4
10
DILA-XHI(V)...
DILA-22(...)
276399
DILA-22(...)
276403
DILA-22(...)
276396
DILA-22(...)
276414
The listed auxiliary and main contacts up to 12 A are available with tension clamp terminations.
The auxiliary contact modules listed for the DILA contactor relay can also be used for the DILM contactors up to 32 A.
Auxiliary contact members: DILA-XHI to EN 50005, DILM32-XHI to DIN 50012
The DILA-22 contactor relay can not be combined with the 4-pole auxiliary contact module.
DILA auxiliary contact modules
2-pole
4-pole
a Dimensions Page 22
24
Contacts
Rated operating
current
M = make contact,
B = break contact
MF = Early-make contacts
BS = Late-break contacts
AC–15
Conventional current,
open at 60 °C
Can be combined
with basic unit
Type
Article no.
DILA...
DILA-XHI02
276420
380 V
400 V
415 V
Ie
Ith
A
A
3
10
–
2B
1M
1B
2M
–
1 MF
1 BS
–
4B
DILA-XHI04
276424
1M
3B
DILA-XHI13
276425
2M
2B
DILA-XHI22
276426
3M
1B
DILA-XHI31
276427
4M
–
DILA-XHI40
276428
1 MF
1 BS
DILA-XHIV22
276429
DILM7...
DILM9...
DILM12...
DILM17...
DILM25...
DILM32...
DILA-XHI11
276421
DILA-XHI20
276422
DILA-XHIV11
276423
Technical data
DILA
DILA-XHI...
General
Lifespan, mechanical
Operations
x 106
20
20
Operations
106
20
20
°C
–25/60
–25/60
AC operated
kg
0.19
DC operated
kg
0.19
Solid
mm2
1 x (0.75 – 4)
Flexible with ferrule
mm2
AC operated
DC operated
x
Ambient temperature
open
Weight
Terminal capacity
Screw terminals
2 x (0.75 – 2.5)
1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
Solid or stranded
AWG
18 – 14
Contacts
Rated insulation voltage
Ui
V AC
690
690
Rated operational voltage
Ue
V AC
690
500
220/240 V
Ie
A
6
6
380/415 V
Ie
A
4
3
500 V
Ie
A
1.5
–
24 V
A
–
–
Fault probability
HF
Rated operational current
AC–15
DC-13 1)
DC-13 L/R F 15 ms
Contacts in series:
1
Control circuit reliability at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA
< 10-8, < 1 failure to 100 mill. switching
operations
Magnet systems
Pick-up and drop-out values
AC operated
50 Hz single-voltage coil and 50/60 Hz dual-voltage coil
Pick-up
x Us
0.8 – 1.1
–
Dual-frequency coil 50/60 Hz
Pick-up
x Us
0.8 – 1.1
–
DC operated 2)
Pick-up voltage
Pick-up
x Us
0.8 – 1.1
–
Without auxiliary contact module (40 °C)
Pick-up
x Uc
0.7 – 1.3
–
Power consumption
50 Hz single-voltage coil and 50/60 Hz dual-voltage coil
Pick-up
VA
24
–
Pick-up
W
19
–
50 Hz single-voltage coil and 50/60 Hz dual-voltage coil
Sealing
VA
4
–
Sealing
W
1.2
–
DC operated
Pick-up = pick-up
W
3
–
Notes
1) Making
and breaking currents to DC-13 time constant as stated
DC or three-phase bridge rectifier
2) Smoothed
25
ZB overload relays
Setting range
Overload
releases
Short-circuit protection
For use with
Ir
A
ZB12 overload relays
Single-phasing sensitivity to
IEC/EN 60947,
VDE 0660 Part 102
Direct fitting
0.1 – 0.16
0.16 – 0.24
0.24 – 0.4
0.4 – 0.6
0.6 – 1
97 95
2
4
6
98 96 A2 14/
22
ZB32 overload relays
Single-phasing sensitivity to
IEC/EN 60947,
VDE 0660 Part 102
Direct fitting
4
6
98 96 14/
22
ZB65 overload relays
Single-phasing sensitivity to
IEC/EN 60947,
VDE 0660 Part 102
Direct fitting
97 95
2
26
4
6
98 96
Classification type
“1”
gG/gL
A
“2”
gG/gL
A
25
0.5
1
DIULM7,
DIULM9,
DIULM12,
2
4
SDAINLM12,
SDAINLM16,
SDAINLM22
4
6
1.6 – 2.4
10
2.4 – 4
16
4–6
20
6 – 10
50
25
9 – 12
50
25
25
0.5
0.1 – 0.16
0.16 – 0.24
0.24 – 0.4
0.6 – 1
2
Article no.
Classification type
1 – 1.6
0.4 – 0.6
97 95
DILM7,
DILM9,
DILM12,
DILM17,
DILM25,
DILM32,
1
DIULM17,
DIULM25,
DIULM32
2
4
SDAINLM30,
SDAINLM45,
SDAINLM55
4
1 – 1.6
6
1.6 – 2.4
10
2.4 – 4
16
4–6
20
6 – 10
50
25
10 – 16
63
35
16 – 24
100
35
24 – 32
125
63
50
25
63
35
63
50
24 – 40
125
63
40 – 57
160
80
50 – 65
160
100
6 – 10
10 – 16
16 – 24
DILM40,
DILM50,
DILM65,
DIULM40,
DIULM50,
DIULM65
Type
ZB12-0.16
278431
ZB12-0.24
278432
ZB12-0.4
278433
ZB12-0.6
278434
ZB12-1.0
278435
ZB12-1.6
278436
ZB12-2.4
278437
ZB12-4
278438
ZB12-6
278439
ZB12-10
278440
ZB12-12
278441
ZB32-0.16
278442
ZB32-0.24
278443
ZB32-0.4
278444
ZB32-0.6
278445
ZB32-1.0
278446
ZB32-1.6
278447
ZB32-2.4
278448
ZB32-4
278449
ZB32-6
278450
ZB32-10
278451
ZB32-16
278452
ZB32-24
278453
ZB32-32
278454
ZB65-10
278455
ZB65-16
278456
ZB65-24
278457
ZB65-40
278458
ZB65-57
278459
ZB65-65
278460
Overload release:
tripping class 10 A
Short-circuit protection:
when fitting directly, note
maximum admissible fuse for the
contactor.
Suitable for the protection of EEx
e-motors. EU prototype test
certificate available on request.
Overload release:
tripping class 10 A
Short-circuit protection:
when fitting directly, note
maximum admissible fuse for the
contactor.
Suitable for the protection of EEx
e-motors. EU prototype test
certificate available on request.
Overload release:
tripping class 10 A
Short-circuit protection:
when fitting directly, note
maximum admissible fuse for the
contactor.
Suitable for the protection of EEx
e-motors. EU prototype test
certificate available on request.
Technical data Overload relays
ZB12, ZB32
ZB65
General
Standards and regulations
IEC/EN 60947, VDE 0660, UL, CSA
Ambient temperature
open1)
°C
–25/50
–25/50
enclosed1)
°C
–25/40
–25/40
V AC
690
690
Main contacts
Rated operational voltage
Ue
Terminal capacity
Solid
mm2
2 x (1 – 6)
2 x (1 – 16)
Flexible without ferrule
mm2
–
–
Flexible with ferrule
mm2
2 x (1 – 4)
1 x 25
2 x (1 – 6)2)
2 x (1 – 10)3)
AWG
14 – 8
14 – 2
Ith
A
6
6
Make contact 240 V
Ie
A
1.5
1.5
415 V
Ie
A
0.5
0.5
500 V
Ie
A
0.5
0.5
240 V
Ie
A
1.5
1.5
415 V
Ie
A
0.9
0.9
500 V
Ie
A
0.8
0.8
24 V
Ie
A
0.9
0.9
60 V
Ie
A
0.75
0.75
110 V
Ie
A
0.4
0.4
220 V
Ie
A
0.2
0.2
Solid or stranded
Auxiliary circuits and control circuits
Conventional free air thermal current
Rated operational current
AC–15
Break
contact
DC-13 L/R F 15
ms4)
1) Ambient
temperature: operating range to IEC/EN 60947, PTB: –5 °C to +50 °C
2) 6 mm2 flexible with ferrule to DIN 46228
3) Terminal capacity of main contacts solid and flexible with ferrule:
when using 2 conductor of equal cross-section
4) Rated operational current: making and breaking currents to DC-13, time constant as stated
Notes
Dimensions
ZB12/ZB32
ZB65
35.5
51.5
79.2
48
29.5
39.5
20.3
45
65
83
60
95.5
102
27
Direct-on-line starter, 400/415 V
Motor starter
Motor data
Actuating voltage
230 V 50 Hz
Actuating voltage
24 V DC
Type
Article no.
Type
Article no.
AC-3
380 V
400 V
415 V
Rated
operational
current
400 V
Rated shortcircuit current
380 – 415 V
Overload
release
Short-circuit
release
P
Ie
Iq
Ir
Irm
kW
A
kA
A
A
Complete units
PKZ and DILM
0.06
0.21
100
0.16 – 0.25
3.5
MSC-D-0.25-M7 (...)
281925
MSC-D-0.25-M7 (...)
283154
Classification type “1”1)
0.09
0.31
100
0.25 – 0.4
5.6
MSC-D-0.4-M7 (...)
281926
MSC-D-0.4-M7 (...)
283155
0.12
0.41
100
0.40 – 0.63
8.82
MSC-D-0.63-M7 (...)
281927
MSC-D-0.63-M7 (...)
283156
0.18
0.6
100
0.40 – 0.63
8.82
MSC-D-0.63-M7 (...)
281927
MSC-D-0.63-M7 (...)
283156
0.25
0.8
100
0.63 – 1
14
MSC-D-1-M7 (...)
281929
MSC-D-1-M7 (...)
283158
0.37
1.1
100
1.00 – 1.6
22.4
MSC-D-1.6-M7 (...)
283140
MSC-D-1.6-M7 (...)
283159
0.55
1.5
100
1.00 – 1.6
22.4
MSC-D-1.6-M7 (...)
283140
MSC-D-1.6-M7 (...)
283159
0.75
1.9
100
1.60 – 2.5
35
MSC-D-2.5-M7 (...)
283142
MSC-D-2.5-M7 (...)
283161
1.1
2.6
100
2.50 – 4
56
MSC-D-4-M7 (...)
283143
MSC-D-4-M7 (...)
283162
1.5
3.6
100
2.50 – 4
56
MSC-D-4-M7 (...)
283143
MSC-D-4-M7 (...)
283162
2.2
5
100
4.00 – 6.3
88.2
MSC-D-6.3-M7 (...)
283145
MSC-D-6.3-M7 (...)
283164
3
6.6
100
6.30 – 10
140
MSC-D-10-M7 (...)
283146
MSC-D-10-M7 (...)
283165
4
8.5
100
6.30 – 10
140
MSC-D-10-M9 (...)
283147
MSC-D-10-M9 (...)
283166
5.5
11.3
100
8 – 12
168
MSC-D-12-M12 (...)
283148
MSC-D-12-M12 (...)
283167
7.5
16
50
10 – 16
224
MSC-D-16-M17 (...)
283150
MSC-D-16-M17 (...)
283168
11
21.7
50
20 – 25
350
MSC-D-25-M25 (...)
283151
MSC-D-25-M25 (...)
283169
15
29.3
50
25 – 32
448
MSC-D-32-M32 (...)
283152
MSC-D-32-M32 (...)
283170
Notes
28
Setting range
1) For
classification type “2”, please inquire.
Direct-on-line starter, 400/415 V
Motor-protective
circuit-breakers
Contactor
Direct-on-line starter set
Mechanical connection module +
electrical contact module
Type
Type
Type
PKZM0-0,25
DILM7-10
PKZM0-XD M12
PKZM0-0,4
DILM7-10
PKZM0-XD M12
PKZM0-0,63
DILM -10
PKZM0-XD M12
PKZM0-0,63
DILM7-10
PKZM0-XD M12
PKZM0-1
DILM7-10
PKZM0-XD M12
PKZM0-1,6
DILM7-10
PKZM0-XD M12
PKZM0-1,6
DILM7-10
PKZM0-XD M12
PKZM0-2,5
DILM7-10
PKZM0-XD M12
PKZM0-4
DILM7-10
PKZM0-XD M12
PKZM0-4
DILM7-10
PKZM0-XD M12
PKZM0-6,3
DILM7-10
PKZM0-XD M12
PKZM0-10
DILM7-10
PKZM0-XD M12
PKZM0-10
DILM9-10
PKZM0-XD M12
PKZM0-12
DILM12-10
PKZM0-XD M12
PKZM0-16
DILM17-10
PKZM0-XD M32
PKZM0-25
DILM25-10
PKZM0-XD M32
PKZM0-32
DILM32-10
PKZM0-XD M32
Notes
The direct-on-line starters (complete units) consist of a PKZM0
motor-protective circuit-breaker and a DILM contactor.
Up to 12 A, starters are mounted without adapter plates, with
only the motor-protective circuit-breaker being secured to the
top-hat rail. The contactors receive their mechanical hold via a
mechanical connection module.
From 16 A, motor-protective circuit-breakers and contactors are
mounted on top-hat-rail adapter plates.
The connection of the main contacts between PKZ and contactor
is effected via an electrical contact module.
29
Reversing starter 400/415 V
Motor starter
Motor data
Complete units
Setting range
Notes
30
Actuating voltage
24 V DC
Type
Article no.
Type
Article no.
Rated shortcircuit current
380 – 415 V
Overload
release
Short-circuit
releases
e
Iq
Ir
Irm
kW
A
kA
A
A
0.06
0.21
100
0.16 – 0.25
3.5
MSC-R-0.25-M7 (...)
283171
MSC-R-0.25-M7 (...)
283190
0.09
0.31
100
0.25 – 0.4
5.6
MSC-R-0.4-M7 (...)
283172
MSC-R-0.4-M7 (...)
283191
0.12
0.41
100
0.40 – 0.63
8.82
MSC-R-0.63-M7 (...)
283173
MSC-R-0.63-M7 (...)
283192
0.18
0.6
100
0.40 – 0.63
8.82
MSC-R-0.63-M7 (...)
283173
MSC-R-0.63-M7 (...)
283192
0.25
0.8
100
0.63 – 1
14
MSC-R-1-M7 (...)
283175
MSC-R-1-M7 (...)
283194
0.37
1.1
100
1.00 – 1.6
22.4
MSC-R-1.6-M7 (...)
283176
MSC-R-1.6-M7 (...)
283195
0.55
1.5
100
1.00 – 1.6
22.4
MSC-R-1.6-M7 (...)
283176
MSC-R-1.6-M7 (...)
283195
0.75
1.9
100
1.60 – 2.5
35
MSC-R-2.5-M7 (...)
283178
MSC-R-2.5-M7 (...)
283197
1.1
2.6
100
2.50 – 4
56
MSC-R-4-M7 (...)
283179
MSC-R-4-M7 (...)
283198
1.5
3.6
100
2.50 – 4
56
MSC-R-4-M7 (...)
283179
MSC-R-4-M7 (...)
283198
2.2
5
100
4.00 – 6.3
88.2
MSC-R-6.3-M7 (...)
283181
MSC-R-6.3-M7 (...)
283200
3
6.6
100
6.30 – 10
140
MSC-R-10-M7 (...)
283182
MSC-R-10-M7 (...)
283201
4
8.5
100
6.30 – 10
140
MSC-R-10-M9 (...)
283183
MSC-R-10-M9 (...)
283202
5.5
11.3
100
8 – 12
168
MSC-R-12-M12 (...)
283184
MSC-R-12-M12 (...)
283203
7.5
16
50
10 – 16
224
MSC-R-16-M17 (...)
283186
MSC-R-16-M17 (...)
283204
11
21.7
50
20 – 25
350
MSC-R-25-M25 (...)
283187
MSC-R-25-M25 (...)
283205
15
29.3
50
25 – 32
448
MSC-R-32-M32 (...)
283188
MSC-R-32-M32 (...)
283206
AC-3
380 V
400 V
415 V
Rated
operational
current
400 V
P
PKZ and DILM
Classification type “1”1)
Actuating voltage
230 V 50 Hz
1) For
classification type “2”, please inquire.
Reversing starter 400/415 V
Motor-protective
circuit-breakers
Contactor
Reversing starter set
Mechanical connection module +
electrical contact module and
reversing link
Type
Type
Type
PKZM0-0,25
DILM7-01
PKZM0-XR M12
PKZM0-0,4
DILM7-01
PKZM0-XR M12
PKZM0-0,63
DILM-01
PKZM0-XR M12
PKZM0-0,63
DILM7-01
PKZM0-XR M12
PKZM0-1
DILM7-01
PKZM0-XR M12
PKZM0-1,6
DILM7-01
PKZM0-XR M12
PKZM0-1,6
DILM7-01
PKZM0-XR M12
PKZM0-2,5
DILM7-01
PKZM0-XR M12
PKZM0-4
DILM7-01
PKZM0-XR M12
PKZM0-4
DILM7-01
PKZM0-XR M12
PKZM0-6,3
DILM7-01
PKZM0-XR M12
PKZM0-10
DILM7-01
PKZM0-XR M12
PKZM0-10
DILM9-01
PKZM0-XR M12
PKZM0-12
DILM12-01
PKZM0-XR M12
PKZM0-16
DILM17-01
PKZM0-XR M32
PKZM0-25
DILM25-01
PKZM0-XR M32
PKZM0-32
DILM32-01
PKZM0-XR M32
Notes
The reversing starters (complete units) consist of a PKZM0
motor-protective circuit-breaker and two DILM contactors. Up to
12 A, starters are mounted without adapter plates, with only the
motor-protective circuit-breaker being secured to the top-hat rail.
The contactors receive their mechanical hold via a mechanical
connection module.
From 16 A, motor-protective circuit-breakers and contactors are
mounted on top-hat-rail adapter plates.
The connection of the main contacts between PKZ and contactor
is effected via an electrical contact module.
Complete units with mechanical interlock, starters up to 12 A also
with electrical interlock.
31