C-more Part Number Description Price

C-more Part Number Description Price
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Panels Selection Guide
Company
Information
Control Systems
Overview
C-more Micro Panels
Part Number
Description
Price
C-more Micro touch screen operator interface, 3.1 inch, STN LCD monochrome, 128 x 64
pixel display, selectable screen colors: red, green, amber, lime, or yellow, LED backlight, 5 user
defined function keys, RS-232 (RJ12) port, display supports landscape mode(s), NEMA 4/4X,
IP65, indoor use only.
EA1-S3ML
NonTouch
EA1-S3ML-N
C-more Micro non-touch operator interface, 3.1 inch, STN LCD monochrome, 128 x 64 pixel
display, selectable screen colors: red, green, amber, lime, or yellow, LED backlight, 5 user
defined function keys, RS-232 (RJ12) port, display supports landscape mode(s), NEMA 4/4X,
IP65, indoor use only.
$205.00
CLICK PLC
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
$161.00
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
C-more Micro touch screen operator interface, 3.1 inch, STN LCD monochrome, 128 x 64
pixel display, selectable screen colors: white, pink1, pink 2, pink3 or red, high-contrast white
LED backlight, 5 user defined function keys, RS-232 (RJ12) port, display supports landscape
mode(s), NEMA 4/4X, IP65, indoor use only.
EA1-S3MLW
DirectLOGIC
DL105
$205.00
DirectLOGIC
DL205
DirectLOGIC
DL305
EA1-S3MLW-N
EA1-T4CL
NonTouch
C-more Micro non-touch operator interface, 3.1 inch, STN LCD monochrome, 128 x 64
pixel display, selectable screen colors: white, pink1, pink 2, pink3 or red, high-contrast white
LED backlight, 5 user defined function keys, RS-232 (RJ12) port, display supports landscape
mode(s), NEMA 4/4X, IP65, indoor use only.
C-more Micro touch screen operator interface, 4.1 inch, TFT color LCD, 320 x 240 pixel display,
32K colors, LED backlight, 5 user defined function keys, RS-232 / RS-485 / 422 (15-pin D-sub)
port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X, IP65, indoor use
only.
$161.00
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
$356.00
Universal
Field I/O
Software
EA1-T6CL
C-more Micro touch screen operator interface, 5.7 inch, TFT color LCD, 320 x 240 pixel display,
32K colors, LED backlight, 5 user defined function keys, RS-232 / RS-485 / 422 (15-pin D-sub)
port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X, IP65, indoor use
only.
C-More
HMI
$432.00
C-More Micro
HMI
ViewMarq
Industrial
Marquees
EA3-T6CL
C-more Micro touch screen operator interface, 5.7 inch, TFT color LCD, 320 x 240 pixel display,
32K colors, LED backlight, 5 user defined function keys, RS-232 (RJ12) port, RS-232 / RS-485 /
422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X,
IP65, indoor use only.
$299.00
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
EA3-T8CL
C-more Micro touch screen operator interface, 8.4 inch, TFT color LCD, 800 x 600 pixel display,
32K colors, LED backlight, 7 user defined function keys, RS-232 (RJ12) port, RS-232 / RS-485 /
422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X,
IP65, indoor use only.
$749.00
EA3-T10CL
C-more Micro touch screen operator interface, 10.4 inch, TFT color LCD, 800 x 600 pixel
display, 32K colors, LED backlight, 7 user defined function keys, RS-232 (RJ12) port, RS-232
/ RS-485 / 422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s),
NEMA 4/4X, IP65, indoor use only.
$899.00
Book 1 (14.2)
www.automationdirect.com/C-more-micro
C-more Micro Panels
eCK-11
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Panels Selection Guide
C-more Micro Panel Accessories
Part Number
Description
Price
EA-MG-BZ1
8-button keypad bezel for C-more 3” Micro panels, with four arrow adjust keys, and
ESCAPE, MENU, CLEAR and ENTER buttons. Helps to reduce screen wear in heavy-duty
applications where operators can use the keypad. Designed for easy drop-in of the Micro panels.
$64.00
20-button keypad bezel with numeric keypad for C-more 3” Micro panels, with four arrow
adjust keys, and ESCAPE, MENU, CLEAR and ENTER buttons. Helps to reduce screen wear in
heavy-duty applications where operators can use the keypad to enter numeric data. Designed for
easy drop-in of the Micro panels.
$87.00
EA-MG-P1
Optional DC Power Adapter for C-more 3” Micro panels. Required when using third party
PLCs, or when using 24VDC power instead of the 5VDC supplied from the RJ12 connector of a
Productivity Series, CLICK or Direct LOGIC PLC.
$31.50
EA-MG-SP1
Optional Serial Port with DC Power Adapter for C-more 3” Micro panels. Serial port is a D-Sub
15-pin RS-232/RS-422/485 connector. Required when using RS422, RS485 or third party PLCs.
$54.00
EA-COMCON-3
DSUB port adapter, 15-pin to 6-terminal RS-422/485, right angle connector,
plugs into the 15-pin serial port on rear of touch panel to allow wire terminal
connections for an RS-422/485 communication cable. Compatible with C-more
EA7 series, EA9-T6CL(-R), and C-more Micro 4 or 6-inch panels.
$42.00
EA-COMCON-3A
DSUB port adapter, 15-pin to 6-terminal RS-422/485, straight connector, plugs into the
15-pin serial port on rear of touch panel to allow wire terminal connections for an RS-422/485
communication cable. Compatible with C-more EA9 series panels, C-more Micro EA3 series
panels and EA1-S3x with EA1-MG-SP1. Not recommended with EA9-T6CL(-R) panels.
$19.00
EA-MG6-BZ2
20-button keypad bezel with numeric keypad for EA1-T6CL panels being used in landscape (horizontal) mounted mode, with 2 arrow adjust keys, and ESCAPE, MENU, CLEAR
and ENTER buttons. Helps to reduce screen wear in heavy-duty applications where
operators can use the keypad to enter numeric data. Designed for easy drop-in of the EA1-T6CL
panels.
$107.00
EA-MG6-BZ2P
21-button keypad bezel with numeric keypad for EA1-T6CL panels being
used in Portrait (vertical) mounted mode, with 2 arrow adjust keys, and ESCAPE,
MENU, CLEAR and ENTER buttons. Helps to reduce screen wear in heavy-duty
applications where operators can use the keypad to enter numeric data. Designed for easy
drop-in of the EA1-T6CL panels.
$79.00
EA-MG-COV-CL
Optional clear screen overlay used to protect 3” displays from minor scratches and wear.
Package contains five (5) clear screen overlays.
$35.50
EA-4-COV2
Optional clear screen overlay used to protect 4” displays from minor scratches and wear.
Package contains three (3) clear screen overlays.
$33.50
EA-6-COV2
Optional clear screen overlay used to protect 6” displays from minor scratches and wear.
Package contains three (3) clear screen overlays.
$37.00
EA-8-COV2
Optional clear screen overlay used to protect 8” displays from minor scratches and wear.
Package contains three (3) clear screen overlays.
$40.00
EA-10-COV2
Optional clear screen overlay used to protect 10” displays from minor scratches and wear.
Package contains three (3) clear screen overlays.
$45.50
EA-MG-BZ2
Book 1 (14.2)
eCK-12
C-more Micro Panels
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
C-more 4” Micro Panels Overview
Overview
C-more 4” Micro panel is a full color, TFT model
that offers touch screen capability and customizable
graphics! The 4” panel mounts in a standard 1/4 DIN
cutout.
EA1-T4CL
In addition to the simple panel configuration
software, a very helpful feature is the built-in project
simulator. The project simulator allows you to view your
project on the PC screen as it would appear on the
panel and to test all your screens before downloading
the project to the panel. You can simulate your entire
project at any stage of development and even simulate
the function keys and keypad bezel.
$356.00
NOTE: EA1-T4CL requires Software and Firmware Version 3.00 or later.
Available for free download at www.automationdirect.com.
Getting started
Installing the software and configuring the C-more 4”
Micro panel is simple. You will need the following to
successfully connect and configure a project for the
panel:
• C-more 4” Micro panel
• C-more Micro Programming Software EA-MGPGMSW (Downloadable version available from the
AutomationDirect web site at no charge.)
• C-more Micro USB Programming Cable such as USB-CBLAB6, used to connect between a PC and the Micro panel’s
built-in programming port. The panel will operate in
Low-Power mode when powered by the PC and the
screen brightness is diminished.
• Power source – An external Class 2, 12-24 VDC power
source is required for normal High-Power operation.
Recommended power supplies are AutomationDirect
part numbers PSC-24-015 or PSC-24-030.
• Personal computer – to run the C-more Micro programming software
• Communications Cable (serial) – to connect the C-more
Micro panel to your PLC or other controller with which
the panel will communicate.
Drivers for your Controller
C-more 4” Micro panels have the following drivers
available for connection to Productivity Series, CLICK,
DirectLOGIC and many other devices:
• AutomationDirect Productivity Series
• AutomationDirect Do-more
• AutomationDirect CLICK (Modbus)
• DirectLOGIC K-sequence, DirectLOGIC DirectNET,
DirectLOGIC Modbus (Koyo Addressing)
• Modbus RTU
• Allen Bradley DF1 Full Duplex, Allen Bradley DF1 Half
Duplex, Allen Bradley PLC5 DF1, AB DH485
• Omron Host Link (C200 Adapter, C500)
Omron FINS serial (CJ1, CS1)
• GE SNPX (90/30, 90/70, Micro 90, VersaMax Micro)
• Mitsubishi Melsec FX
• Siemens PPI
• Entivity Modbus RTU
• AutomationDirect GS Drives
• AutomationDirect SOLO Temperature Controllers
• Mitsubishi Q/QnA
Bitmaps
Features
• 320 X 240 pixel graphical display supports bitmaps
• Use bitmap images of pushbuttons, switches, indicators, your company logo
• Use provided library of bitmaps
• Create your own library of bitmaps
Text - 40 lines
• 40 lines by 80 characters of static text in Landscape Orientation
• 54 lines by 59 characters of static text in Portrait Orientation
• Look up text, scroll up to 128 characters
• 30 lines by 40 characters of dynamic text, embedded variables, on/off
phrases, scroll up to 40 characters
• Scroll text object with up to 128 characters
Beep
• Beep to indicate an alarm
• Beep for a special message
• Beep to verify when button is pressed
Bar graphs
• Line, vertical, horizontal, skinny, fat, multiple
Data entry
• Pop-up numeric key pad on the screen
• Increment/decrement a value by touching arrows
Recipes
Each recipe button transfers up to 99 values from PLC source registers to PLC
destination registers and/or from the recipe table to PLC destination registers.
32K Colors
The TFT panel has a palette of 32K colors available to make full use of color for
objects and bitmaps as well as backgrounds.
Up to 999 Screens
C-more Micro supports up to 999 screens. Screen
quantity is limited by memory usage which is
determined by the total bitmaps, objects, etc. that
are used.
Book 1 (14.2)
eCK-36
C-more Micro Panels
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
C-more 4” Micro Panels Overview
Company
Information
Control Systems
Overview
C-more 4” TFT Micro Panel
Part Number
Description
Price
4-inch C-more Micro Touch Panel with TFT Color LCD, 320 x 240 dot, 32,768 color display with
LED backlight. 5 user-defined function keys with LED indicators. Two built-in ports (USB Type-B
port and 15-pin D-sub RS-232/422/485 port). Display supports Portrait and Landscape modes.
NEMA 4/4X, IP65 (when mounted correctly; for indoor use only).
EA1-T4CL
CLICK PLC
Do-More
PLCs Overview
$356.00
Do-More H2
PLC
Do-More T1H
PLC
Note: Software and Firmware Version 3.00 or later is required with model EA1-T4CL. Available for free download at
www.automationdirect.com.
Description
Price
EA-MG-PGMSW
C-more Micro Windows-based programming software for C-more EA1 and EA3 series panels.
Package includes software CD. Requires USB port connection from PC to C-more Micro panel.
Cables sold separately. Downloadable version available from the Web site at no charge.
USB-CBL-AB3
USB-CBL-AB6
USB-CBL-AB10
USB-CBL-AB15
The C-more Micro TFT panel requires a USB A-to-B type cable to connect a personal computer to the panel for programming. (Note: The TFT panel includes a built-in USB to serial
converter and the USB driver will appear as a COM port to the PC when properly installed.
The USB port supplies 5VDC to the TFT panel so that no external power supply is required for
programming.)
DirectLOGIC
DL205
DirectLOGIC
DL305
$25.00
$7.50
$9.50
$18.00
$22.50
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
C-more 4” Micro Panel Accessories
Part Number
DirectLOGIC
DL05/06
DirectLOGIC
DL105
C-more Micro Programming Software
Part Number
DirectLOGIC
PLCs Overview
Description
Price
Software
C-More
HMI
EA-ADPTR-4
EA-COMCON-3
DSUB PLC serial communications port adapter, 15-pin 90-degree. Compatible
with C-more EA7 series, EA9-T6CL(-R) and C-more Micro 4 or 6-inch panels.
DSUB port adapter, 15-pin to 6-terminal RS-422/485, right angle connector,
plugs into the 15-pin serial port on rear of touch panel to allow wire terminal
connections for an RS-422/485 communication cable. Compatible with C-more
EA7 series, EA9-T6CL(-R), and C-more Micro 4 or 6-inch panels.
$39.00
C-More Micro
HMI
ViewMarq
Industrial
Marquees
$42.00
Other HMI
Communications
Appendix
Book 1
EA-4-COV2
Optional clear screen overlay used to protect C-more 4” Micro displays from
minor scratches and wear. Package contains 3 clear screen overlays.
$33.50
For a list of supported protocols and cabling options refer
to the C-more Micro Protocols and cabling chart starting on
page CK-71.
Book 1 (14.2)
www.automationdirect.com/C-more-micro
C-more Micro Panels
eCK-37
Terms and
Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
C-more 4” & 6” Micro PLC Connections
Cabling requirements
Do-More H2
PLC
Expansion
Connector
R**. 1 2 3 4 5
MODEL:EA1-T4CL
USB Type B
Programming Port
R
INPUT:12-24V 0.19-0.38A Class2
Date code:9048
MADE IN CHINA
7M17
IND.CONT.EQ.
Signal
Pin
1
Frame GND
6
LE
11 TXD+ (422/485)
2
TXD (232C)
7
CTS (232C)
12 TXD– (422/485)
3
RXD (232C)
Signal
Pin
Signal
8
RTS (232C)
13 Term. Resistor
4
Supplies +5VDC
9
RXD+ (422/485)
14 do not use
5
Logic GND
10 RXD– (422/485)
15 do not use
RS-232/422/485
PLC 15-pin serial
communications Port2
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
EA3-T6CL
DirectLOGIC
DL305
DirectLOGIC
DL405
Expansion
Connector
RJ12 serial
communications Port1
USB Type B
Programming Port
Productivity
Controller
Overview
Productivity
3000
8
1
15
9
Universal
Field I/O
PLC 15-pin serial
communications Port2
Software
Signal
Pin
Pin
Pin
Signal
Pin
Signal
1
Frame GND
6
LE
11 TXD+ (422/485)
2
TXD (232C)
7
CTS (232C)
12 TXD– (422/485)
3
RXD (232C)
8
RTS (232C)
13 Term. Resistor
4
Supplies +5VDC
9
RXD+ (422/485)
14 do not use
5
Logic GND
10 RXD– (422/485)
15 do not use
Signal
1
Logic GND
2
not used
3
RXD (232C)
6 5 4 3 2 1
•
•
•
•
•
•
•
Pin
+ -
•
Do-More T1H
PLC
EA1-T4CL+094018001
Drivers for your Controller
•
•
CLICK PLC
Do-More
PLCs Overview
The EA1-T4CL and EA1-T6CL can only communicate to a
controller through the 15-pin serial Port2. Port 2. EA3-T6CL
can communicate to a controller through the 15-pin or the
RJ12 serial ports. The USB port is for programming only.
AutomationDirect Productivity Series
AutomationDirect Do-more
AutomationDirect CLICK (Modbus)
DirectLOGIC K-sequence, DirectLOGIC DirectNET, DirectLOGIC
Modbus (Koyo Addressing)
Modbus RTU
Allen Bradley DF1 Full Duplex, Allen Bradley DF1 Half Duplex,
Allen Bradley PLC5 DF1, AB DH485
Omron Host Link (C200 Adapter, C500)
Omron FINS serial (CJ1, CS1)
GE SNPX (90/30, 90/70, Micro 90, VersaMax Micro)
Mitsubishi Melsec FX
Siemens PPI
Entivity Modbus RTU
AutomationDirect GS Drives
AutomationDirect SOLO Temperature Controllers
Mitsubishi Q/QnA
Control Systems
Overview
Communication Ports
EA1-T4CL
The C-more 4” and 6” Micro panels can communicate
through the built-in 15-pin serial port (Port2) via RS-232,
RS-422 and RS-485 using these cables.
• EA-2CBL — connects to CLICK, P3-550, DL05, DL105, DL205,
D3-350 and D4-450 phone jack.
• EA-2CBL-1 — connects to D2-250, D250-1, D2-260, DL06 VGA
connector.
•
•
•
•
Company
Information
4
TXD (232C)
5
Receives 5VDC
6
Logic GND
C-More Micro
HMI
RS-232
RS-232/422/485
C-More
HMI
ViewMarq
Industrial
Marquees
EA1-T6CL
Other HMI
Communications
C-more Micro Port 1 to
CLICK PLC Port 2
Port 2
PLC 15-pin serial
communications Port2
Port 1
DV-1000CBL
serial cable
8
1
15
9
Pin
Signal
Pin
1
Frame GND
6
LE
11 TXD+ (422/485)
2
TXD (232C)
7
CTS (232C)
12 TXD– (422/485)
3
RXD (232C)
Signal
Pin
Signal
8
RTS (232C)
13 Term. Resistor
4
Supplies +5VDC
9
RXD+ (422/485)
14 do not use
5
Logic GND
10 RXD– (422/485)
15 do not use
RS-232/422/485
Book 1 (14.2)
www.automationdirect.com/C-more-micro
Appendix
Book 1
Terms and
Conditions
Expansion
Connector
C-more 6”
Micro
Panel
CLICK PLC
USB Type B
Programming Port
C-more Micro Panels
eCK-59
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Communication Protocols &
Cabling Chart
Controller Compatibility & Connection Chart
PLC
Family
CLICK
CPU
all versions
Analog CPU’s
Productivity Series
Do-more
Entivity
all versions
Protocol(s)
Supported
Port 1
RJ12 - 6 pin
Port 2
RJ12 - 6 pin
Modbus (CLICK)
Port3
Term block 3-pin
RS-232
RJ12 - 6 pin
RS-485 Port
Term block 3-pin
all versions
RS-232
RJ12 - 6 pin
H2-SERIO
RS-232
RJ12 - 6 pin
H2-SERIO-4
RS-232
RJ12 - 6 pin
H2-WinPLC
RS-232
RJ12 - 6 pin
H2-SERIO
RS-232
RJ12 - 6 pin
H2-SERIO-4
RS-232
RJ12 - 6 pin
all versions
Using panel’s RJ12 Port1**
Port 1
RJ12 - 6 pin
Port 2
RJ12 - 6 pin
D0-DCM
Port 2
DB15HD
(female)
Productivity3000 Serial
(P3-550)
Do-more Serial,
K-sequence,
Modbus RTU
D0-CBL
RS-232
N/A
D0-CBL
RS-232
Productivity3000 Serial
(P3-550)
Do-more Serial,
K-sequence,
Modbus RTU
all versions
Port 2
DB15HD
(female)
Port 1
RJ12 - 6 pin
Do-More T1H
PLC
* See Note
RS-485
DirectLOGIC
PLCs Overview
EA-2CBL
RS-232
* See Note
RS-485
EA-2CBL
RS-232
D0-CBL
RS-232
Entivity Modbus RTU
Modbus RTU
EA-2CBL
RS-232
K-sequence,
Direct NET,
Modbus RTU
D0-CBL
RS-232
K-sequence,
Direct NET,
Modbus RTU
EA-2CBL
RS-232
EA-2CBL
RS-232
D0-CBL
RS-232
K-sequence,
Direct NET,
Modbus RTU
D0-CBL
+ FA-15HD
RS-232
K-sequence,
Direct NET,
Modbus RTU
EA-2CBL-1
RS-232
Modbus RTU
* See Note
RS-485
Modbus only
K-sequence,
Direct NET,
Modbus RTU
K-sequence,
Direct NET,
Modbus RTU
D0-CBL
+ FA-15HD
RS-232
K-sequence
K-sequence,
Direct NET,
Modbus RTU
D0-CBL
+ FA-15HD
RS-232
D0-CBL
RS-232
EA-2CBL-1
RS-232
DirectLOGIC
DL105
DirectLOGIC
DL205
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
EA-2CBL-1
RS-232
* See Note
RS-422
Modbus RTU
* See Note
RS-485
Modbus only
K-sequence
EA-2CBL
RS-232
**Note: These charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory
for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect
PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power
supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options.
PLC Compatibility & Connection Chart continued on next page.
Book 1 (14.2)
C-more Micro Panels
DirectLOGIC
DL405
* See Note
RS-485
Modbus only
* Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user
can use to construct their own cables. The manual is available for download at www.automationdirect.com.
www.automationdirect.com/C-more-micro
DirectLOGIC
DL05/06
* See Note
RS-422
EA-2CBL
RS-232
D0-CBL
RS-232
K-sequence,
Direct NET,
Modbus RTU
* See Note
RS-422
EA-2CBL
RS-232
D0-CBL
RS-232
Port 1
RJ12 - 6 pin
D0-DCM
Do-More H2
PLC
EA-2CBL
RS-232
Entivity Modbus RTU
Modbus RTU
Modbus RTU
Direct LOGIC
DL06
Direct LOGIC
DL105
Port 2
DB15HD
(female)
Modbus (CLICK)
Do-More
PLCs Overview
DirectLOGIC
DL305
Port 1
RJ12 - 6 pin
all versions
D0-CBL
RS-232
Using panel’s Port2**
DB 15-pin - female
Protocol(s)
Components &
Supported
Network Type
N/A
Port 1
RJ12 - 6 pin
Direct LOGIC
DL05
Components &
Network Type
Control Systems
Overview
CLICK PLC
C-more Micro Panel
PLC Port &
Type
Company
Information
eCK-71
Terms and
Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Communication Protocols &
Cabling Chart (cont’d)
Controller Compatibility & Connection Chart
PLC
C-more Micro Panel
Family
CPU
Port & Type
D2-230
D2-240
Using panel’s RJ12 port 1**
Protocol(s)
Supported
Components &
Network Type
Port 1
RJ12 - 6 pin
K-sequence
D0-CBL
RS-232
Port 1
RJ12 - 6 pin
K-sequence
Port 2
RJ12 - 6 pin
K-sequence,
Direct NET,
D0-CBL
RS-232
Port 2
DB15HD
(female)
K-sequence,
Direct NET,
Modbus RTU
D0-CBL
+ FA-15HD
RS-232
D2-260
Port 2
DB15HD
(female)
K-sequence
K-sequence,
Direct NET,
K-sequence,
Direct NET,
Modbus RTU
EA-2CBL
RS-232
EA-2CBL-1
RS-232
* See Note
RS-422
EA-2CBL
RS-232
K-sequence,
Direct NET,
Modbus RTU
K-sequence,
Direct NET,
Modbus RTU
EA-2CBL
RS-232
EA-2CBL
RS-232
D0-CBL
RS-232
Port 1
RJ12 - 6 pin
Direct LOGIC
DL205
K-sequence
D0-CBL
RS-232
D2-250-1
D2-250-1
Using panel’s Port2**
DB 15-pin - female
Protocol(s)
Components &
Supported
Network Type
D0-CBL
+ FA-15HD
RS-232
EA-2CBL-1
RS-232
* See Note
RS-422
Modbus RTU
* See Note
RS-485
Modbus only
EA-4CBL-2
RS-232
D2-DCM
Port 1
DB 25 pin
(female)
K-sequence,
Direct NET,
Modbus RTU
*See Note
RS-232
Direct NET
WINPLC
Port 1
RJ12 - 6 pin
Modbus RTU
D0-CBL
RS-232
Modbus RTU
EA-2CBL
RS-232
D3-330 or
D3-340
D3-232-DCU
DB 25 pin
(female)
Direct NET
D0-CBL
+FA-CABKIT
RS-232
Direct NET
EA-4CBL-2
RS-232
Direct NET
*See Note
RS-422
D3-422-DCU
DB 25 pin
(female)
D3-340
Direct LOGIC
DL305
D3-350
D3-DCM
D3-350 only
N/A
Port 1
RJ11 - 4 pin
Direct NET
Port 2
RJ11 - 4 pin
Direct NET,
Modbus RTU
Port 1
RJ12 - 6 pin
K-sequence,
Direct NET
D0-CBL
RS-232
K-sequence,
Direct NET
Port 2
DB 25 pin
(female)
K-sequence,
Direct NET,
Modbus RTU
*See Note
RS-232
K-sequence,
Direct NET,
Modbus RTU
Port 1
DB 25 pin
(female)
K-sequence,
Direct NET,
Modbus RTU
*See Note
RS-232
Direct NET
OP-3CBL-1
RS-232
Direct NET
Direct NET,
Modbus RTU
* See Note
RS-422
EA-3CBL
RS-232
EA-2CBL
RS-232
EA-4CBL-2
RS-232
*See Note
RS-422
EA-4CBL-2
RS-232
*See Note
RS-422
* Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user
can use to construct their own cables. The manual is available for download at www.automationdirect.com.
**Note: T hese charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory
for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect
PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power
supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options.
PLC Compatibility & Connection Chart continued on next page.
Book 1 (14.2)
eCK-72
C-more Micro Panels
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Communication
Protocols & Cabling Chart (cont’d)
Company
Information
Control Systems
Overview
CLICK PLC
Controller Compatibility & Connection Chart
PLC
Family
Do-More
PLCs Overview
C-more Micro Panel
CPU
Port & Type
Using panel’s RJ12 port 1**
Using panel’s Port2**
DB 15-pin - female
Protocol(s)
Components &
Supported
Network Type
Protocol(s)
Supported
Components &
Network Type
Port 0
DB 15 pin
(female)
K-sequence
D0-CBL
& FA-CABKIT
RS-232
K-sequence
Port 1
DB 25 pin
(female)
K-sequence,
Direct NET
D0-CBL
& FA-CABKIT
RS-232
K-sequence,
Direct NET
EA-4CBL-2
RS-232
*See Note
RS-422
K-sequence
D0-CBL
& FA-CABKIT
RS-232
K-sequence
EA-4CBL-1
RS-232
D4-430
Port 0
DB 15 pin
(female)
D4-440
Direct LOGIC
DL405
D4-450
EA-4CBL-1
RS-232
Port 1
DB 25 pin
(female)
K-sequence,
Direct NET
D0-CBL
& FA-CABKIT
RS-232
K-sequence,
Direct NET
EA-4CBL-2
RS-232
*See Note
RS-422
Port 0
DB 15 pin
(female)
K-sequence
D0-CBL
& FA-CABKIT
RS-232
K-sequence
EA-4CBL-1
RS-232
K-sequence,
Direct NET,
Modbus RTU
EA-4CBL-2
RS-232
*See Note
RS-422
K-sequence,
Direct NET,
Modbus RTU
*See Note
RS-422
K-sequence,
Direct NET
EA-2CBL
RS-232
Port 1
DB 25 pin
(female)
D0-CBL
& FA-CABKIT
RS-232
K-sequence,
Direct NET,
Modbus RTU
Port 3
DB 25 pin
(female)
N/A
D0-CBL
RS-232
Port 2
RJ12 - 6 pin
K-sequence,
Direct NET
D4-DCM
Port 1
DB 25 pin
(female)
K-sequence,
Direct NET,
Modbus RTU
SOLO
N/A
Data +/terminals
N/A
SOLO Temperature
Controller
*See Note
RS-485
GS Drives
N/A
RS-485 Interface
N/A
GS Drives Serial GS
Drives TCP/IP (GS-EDRV)
*See Note
RS-485
*See Note
RS-232
Direct NET
EA-4CBL-2
RS-232
*See Note
RS-422
* Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user
can use to construct their own cables. The manual is available for download at www.automationdirect.com.
**Note: These charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory
for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect
PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power
supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options.
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
PLC Compatibility & Connection Chart continued on next page.
Book 1 (14.2)
www.automationdirect.com/C-more-micro
Do-More H2
PLC
C-more Micro Panels
eCK-73
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Communication
Protocols & Cabling Chart (cont’d)
Controller Compatibility & Connection Chart
PLC
C-more Micro Panel
Family
CPU
Allen-Bradley
MicroLogix
1000, 1100,
1200, 1400, 1500
Allen-Bradley
SLC500
Port & Type
Using panel’s RJ12 port 1**
Protocol(s)
Supported
Components &
Network Type
Using panel’s Port2**
DB 15-pin - female
Protocol(s)
Components &
Supported
Network Type
8-pin
mini-din port
DF1 Full Duplex
DF1 Half Duplex
EA-MLOGIX-CBL
RS-232
RJ45 8-pin
phone plug
DH485/AIC/AIC+
EA-DH485-CBL
RS-232
5/03, 5/04,
5/05
9-pin
D-sub port
DF1 Full Duplex
DF1 Half Duplex
EA-SLC-232-CBL
RS-232
5/01, 5/02,
5/03
RJ45 8-pin
phone plug
DH485/AIC/AIC+
EA-DH485-CBL
RS-232
Allen-Bradley
ControlLogix
Allen-Bradley
CompactLogix
Allen-Bradley
FlexLogix
all
9-pin
D-sub port
DF1 Full Duplex
DF1 Half Duplex
EA-SLC-232-CBL
RS-232
all
9-pin
D-sub port
DF1 Full Duplex
DF1 Half Duplex
EA-SLC-232-CBL
RS-232
all
9-pin
D-sub port
DF1 Full Duplex
DF1 Half Duplex
EA-SLC-232-CBL
RS-232
Allen-Bradley
PLC5
25-pin
D-sub port
DF1 Full Duplex
all
EA-PLC5--232-CBL
RS-232
RJ45 8-pin
phone plug
DH485/AIC/AIC+
EA-DH485-CBL
RS-232
90/30
GE
Micro 90,
VersaMax
Micro
Melsec
FX Series
Mitsubishi
Q / QnA
C200 (Adapter),
C500
Omron
Modicon
Siemens
CJ1, CS1,
CQM1,
CPM1,
CPM2,
C200
984 CPU,
Quantum
113 CPU,
AEG
Modicon
Micro Series
110 CPU
S7-200
CPU
EA-90-30-CBL
RS-422
15-pin
D-sub port
RJ45
Port 1
15-pin
D-sub port
Port 2
25-pin
D-sub port
8-pin
mini-din port
9-pin
D-sub port
6-pin
mini-din port
SNPX
N/A
*See Note
RS-232
EA-90-30-CBL
RS-422
CPU Direct
Q / QnA
EA-MITSU-CBL
RS-422
EA-MITSU-CBL-1
RS-422
*See Note
RS-232
*See Note
RS-232
25-pin
D-sub port
Host Link
EA-OMRON-CBL
RS-232
9-pin
D-sub port
FINS
*See Note
RS-232
varies
Modbus RTU
*See Note
RS-232
9-pin
D-sub port
0 or 1
PPI
*See Note
RS-485
* Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user
can use to construct their own cables. The manual is available for download at www.automationdirect.com.
**Note: T hese charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory
for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect
PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power
supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options.
Book 1 (14.2)
eCK-74
C-more Micro Panels
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
C-more 8” & 10” Micro Communication
Cables and Cable Kits
Cable
Description
Cable
Part Number
Control Systems
Overview
CLICK PLC
Price
Cables used with RJ-12 RS-232 serial Port1
AutomationDirect Productivity Series, Do-more, CLICK, Direct
LOGIC PLC RJ-12 port, DL05, DL06, DL105, DL205,
D3-350, D4-450 & H2-WinPLC (RS-232C)
3.66m (12ft) cable length
Direct LOGIC (VGA Style) 15-pin port, DL06,
D2-250 (250-1), D2-260 (RS-232C)
Use with D0-CBL cable.
Company
Information
Do-More
PLCs Overview
D0-CBL
D0-CBL
Do-More H2
PLC
$19.00
FA-15HD
Do-More T1H
PLC
$8.00
Direct LOGIC PLC 15-pin D-sub port, DL405 (RS-232C)
Use with D0-CBL cable.
FA-CABKIT
$40.00
Direct LOGIC PLC RJ-11 port, D3-340 (RS-232C)
2m (6.56 ft) cable length
OP-3CBL-1
$6.00
OP-3CBL-1
FA-15HD
DirectLOGIC
DL05/06
DirectLOGIC
DL105
Cables used with 15-pin RS-232/422/485 serial Port2
AutomationDirect Productivity Series, Do-more, CLICK, Direct
LOGIC PLC RJ-12 port, DL05, DL06, DL105, DL205,
D3-350, D4-450 & H2-WinPLC (RS-232C)
3m (9.8 ft) cable length
EA-2CBL
Direct LOGIC (VGA Style) 15-pin port, DL06,
D2-250 (250-1), D2-260 (RS-232C)
3m (9.8 ft) cable length
EA-2CBL-1
$20.00
Direct LOGIC PLC RJ-11 port, D3-340 (RS-232C).
3m (9.8 ft) cable length
EA-3CBL
$20.00
Direct LOGIC DL405 PLC 15-pin D-sub port, DL405
(RS-232C). 3m (9.8 ft) cable length
EA-4CBL-1
$20.00
Direct LOGIC PLC 25-pin D-sub port, DL405,
D3-350, DL305 DCU and all DCM’s (RS-232C).
3m (9.8 ft) cable length
EA-4CBL-2
$20.00
Allen-Bradley MicroLogix 1000, 1100, 1200, 1400 & 1500
(RS-232C) 3m (9.8 ft) cable length
EA-MLOGIX-CBL
Allen-Bradley SLC 5-03/04/05, ControlLogix,
CompactLogix, FlexLogix DF1 port (RS-232C)
3m (9.8 ft) cable length
EA-SLC-232-CBL
Allen-Bradley PLC-5 DF1 port (RS-232C)
3m (9.8 ft) cable length
EA-PLC5-232-CBL
$20.00
Allen-Bradley MicroLogix, SLC-5-01/02/03,
PLC5 DH485 port (RS-232C) 3m (9.8 ft) cable length
EA-DH485-CBL
$20.00
GE 90/30 and 90/70, Micro 90, VersaMax Micro (Port 2)
15-pin D-sub port (RS-422A)
3m (9.8 ft) cable length
EA-90-30-CBL
$20.00
MITSUBISHI FX Series 25-pin port
(RS-422A) 3m (9.8 ft) cable length
EA-MITSU-CBL
$20.00
DirectLOGIC
DL205
FA-CABKIT
$20.00
DirectLOGIC
DL305
DirectLOGIC
DL405
EA-2CBL
EA-2CBL-1
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
$30.00
Software
$20.00
EA-3CBL
EA-4CBL-1
EA-MITSU-CBL-1
$20.00
OMRON Host Link C200 Adapter, C500
(RS-232C) 3m (9.8 ft) cable length
EA-OMRON-CBL
$20.00
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Communications
EA-MLOGIX-CBL
EA-4CBL-2
EA-PLC5-232-CBL
EA-MITSU-CBL
EA-MITSU-CBL-1
EA-SLC-232-CBL
EA-OMRON-CBL
Book 1 (14.2)
www.automationdirect.com/C-more-micro
Appendix
Book 1
Terms and
Conditions
EA3-T8CL and EA3-T10CL cannot be powered by a PLC and
cannot communicate with a PLC through the USB Programming Port.
EA-90-30-CBL
C-More
HMI
Other HMI
MITSUBISHI FX Series 8-pin mini-DIN
(RS-422A) 3m (9.8 ft) cable length
EA-DH485-CBL
DirectLOGIC
PLCs Overview
C-more Micro Panels
eCK-75
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Programming Software
FREE software!
C-more Micro Programming Software can be downloaded at no charge or
a CD version may be purchased by ordering EA-MG-PGMSW. The software
requires a USB port on your PC to connect to the C-more Micro panel.
Software Help Files are included in the download. This software programs all
the C-more Micro panels (does not program the C-more 6” through 15” touch
panels).
Note: This software is used to program C-more
Micro panels only.
Part Numbers: EA1-S3ML, EA1-S3ML-N, EA1-S3MLW,
EA1-S3MLW-N, EA1-T4CL, EA1-S6ML, EA1-S6MLW,
EA1-T6CL, EA3-T6CL, EA3-T8CL, EA3-T10CL
C-more Micro Programming Software is
a spin-off of its powerful sibling C-more
Touch Panel. It offers very high end
features designed to reduce your
configuration time. Simply drag and
drop the objects from the object list
(right side of screen) onto the screen
construction area. Then configure your
PLC tags and click on the objects you
wish to use. Use the built-in simulator
to review your work on your PC before
ever downloading your project! The
time saving benefits of the C-more
Micro configuration software could
easily pay for the panel. Check out
www.CmoreMicro.com to download a
free version.
Thumbnail
project
preview
pane
NOTES: Software and Firmware Version 3.5 or later is required
with model EA3-T6CL.
Software and Firmware Version 3.5 or later is required with
models EA3-T8CL and EA3-T10CL.
Software and Firmware Version 3.0 or later is required with
model EA1-T4CL.
Software and Firmware Version 2.5 or later is required with
model EA1-T6CL.
Software and Firmware Version 2.0 or later is required with
models EA1-S6ML and EA1-S6MLW.
Software and Firmware Version 1.5 or later is required with
models EA1-S3MLW and EA1-S3MLW-N.
Available for free download at www.automationdirect.com.
Built-in project simulator
• Runs your project on your PC
• Test all of your screens before downloading
• Time savings pays for the panel
Built-in user object/
screen libraries
Save time by re-using your
objects and screens.
custom
• Version 2.5 or later - Simulate function keys
and keypad bezel.
Scrolling
object
selection
window
Lets you find the
object you want
fast. Just drag
and drop it on
the screen.
Helps keep track of
multi-screen projects.
PC requirements
Scrolling help window
Following are the minimum system requirements for running C-more Micro Gives you helpful information on each object
Programming Software, EA-MG-PGMSW, on a PC:
•O
perating System - Windows® XP Professional Edition Service Pack 2, Windows® 7 (32 or 64
bit) or Windows 8 (32 or 64 bit)
• 150 MB free hard-disk space
•C
D-ROM or DVD drive for installing software from the CD, or internet access to download free
programming software
•U
SB port to use with the correct Programming Cable Assembly for project transfer from the
programming software to the panel
Book 1 (14.2)
eCK-76
C-more Micro Panels
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Programming Software
Company
Information
C-more Micro Panel Objects
Object
Graphic
Object
Graphic
Control Systems
Overview
CLICK PLC
Shape objects, just like with drawing tools, allow the user to insert shapes, such
as a straight line, circle, or rectangle drawing into a project. When a Shape is
inserted into a project, a window opens to allow the user to setup all available
parameters for the Line object. Some of the uses for Shape Objects include but
are not limited to adding callouts, pointers, or indicators.
The Bitmap Button object offers the ability to use a Bitmap graphic to perform the
functions of a Button. This allows users to create their own graphics and implement them within the software project. The Bitmap Button object can be used
to activate or deactivate components assigned to a Discrete Tag Name. The
C-more Micro display only supports two colors, black and white.
The Frame object allows the user to insert a Frame to the project that can be used
to Frame other objects. Some of the uses for Frame object include but are not
limited to graphically separating objects for different operations that may appear
on one screen and emphasizing pushbuttons or other objects that may require
more attention by the operator.
The Static Bitmap offers the ability to display a Bitmap graphic on any screen. The
Static Bitmap does not change state. Refer to the Dynamic Bitmap Object if you
require the graphic object to change state based on a Tag Value in your PLC.
The dialog box for a “Static Bitmap” object allows you to “read from disk” and
select a graphic file for import. Graphics must be in one of the following formats:
.BMP .WMF .JPG .JPEG
Do-More H2
PLC
The Pushbutton object is available from the Button Category of the Object List
window. The Pushbutton object is an electronic version of a typical Pushbutton
normally found on control panels. The Pushbutton object can be used to activate
or deactivate components assigned to a Discrete Tag Name.
Recipe objects make it easy to make a large number of tag changes with the
push of a single button. Create Recipes with up to 99 entries, and multiple sets
of values. Then just push a button to load an entire set of values into the group
of recipe tags.
DirectLOGIC
PLCs Overview
The Switch object is an electronic version of a typical Switch that normally can be
found on control panels. The Switch object can be used to activate or deactivate
components assigned to a Discrete Tag Name.
The Dynamic Bitmap object offers the ability to make an object using two different
Bitmap graphics that will display one graphic when the Tag is On and a different
graphic when the Tag is Off. Use your own bitmap designs or use some of the
bitmaps provided with the software that are located in the User Graphic Library.
The Indicator Button object is available from the Button Category of the Object List
window. The Indicator Button object is an electronic version of a typical Indicator
Button normally found on control panels. The Indicator Button is a combination of
a Pushbutton and an Indicator Light. The Indicator Button can be used to activate or
deactivate components assigned to a Discrete Tag Name.
The Static Text object is used to display a Frame with a personalized Message.
This Frame and Message can be placed on any screen and any location within
the screen.
The Indicator Light object is an electronic version of a typical Indicator Light
normally found on industrial control panels. The Indicator Light can be configured to display the status of the assigned Discrete Tag Name.
The Lookup Text object is used to display a Frame with a personalized Message.
This Frame and Message can be placed on any screen and any location within
the screen. The object is always displayed like a sign but is configured to display
only the message prompted by an assigned Tag Name. Messages are retrieved
from a Message Database which is configured by the user with text defined by the
user. The Lookup Text Object will scroll text up to 128 characters.
The Graphic Indicator Light object is a more enhanced version of the “Indicator
Light Object” that allows the user to choose more detailed graphics to display
the status of a tag. This object is an electronic version of a typical Indicator Light
normally found on industrial control panels. The Indicator Light can be configured to display the status of the assigned Discrete Tag Name.
The Dynamic Text object is used to display text that is retrieved from data stored
in a Tag. The Tag Name is assigned to registers in the PLC that contain set character data. The data can be stored in the PLC in ASCII format and may include
information such as machine numbers, locations, part numbers, and such. The
Message can be configured to be visible (Trigger) when an associated Tag Name
is On or Off. This object can be placed on any screen and any location within the
screen. The Dynamic Text Object will scroll text up to 40 characters.
The Numeric Display consists of a frame that displays a real-time numeric value
according to the value of data received from an assigned Tag Name. The
Numeric Display supports numeric Signed Decimal, Unsigned Decimal, BCD,
and Floating Point data types with up to 11 digits, including decimal point. User
Defined Alpha Numeric Prefix and Suffix values are also supported.
The Scroll Text object is available from the Text Category of the Object List
window. The Scroll Text object is an electronic version of a marquee. It is similar
to the Static Text Object. If the text in the object does not fit in the window, it will
scroll from right to left across the window. The Scroll Text object does not require
a Tag Name assignment. The Scroll Text Object has a maximum character limit
of 128 characters.
The Numeric Entry object is used to enter a value from your Panel to a PLC
Register. This object, when selected, opens a Numeric Keypad that allows the
user to enter a new value that will be written to the assigned Tag Name. The
Numeric Entry supports numeric Signed Decimal, Unsigned Decimal, BCD, and
Floating Point data types with up to 11 digits, including decimal points. User
Defined Alpha Numeric Prefix and Suffix values are also supported.
The Text Entry object is used to enter an ASCII string. Two entry options allow
use of an on-screen keypad or the hardware function keys to enter characters.
The Increment/Decrement Value object is used to add or subtract a value by
pressing a button on the Panel. Basically the object uses two Tags, one to read a
value from and another to write a modified value to. The Increment/Decrement
Value supports numeric Signed Decimal, Unsigned Decimal, BCD, and Floating
Point data types with up to 11 digits, including decimal points. The Increment and
decrement values are also user selectable.
The Screen Change Pushbutton object is available from the Control Category of
the Object List window. The Screen Change Pushbutton object is a pushbutton
that can be configured to activate another screen in the project. This object
may be edited to various colors and sizes. Users can configure the button to
activate the Power-Up screen, Forward Screen, Previous Screen, or any one of
the project screens.
The Real Time Graph object displays the value stored in up to two PLC tags, over a
history of up to 24 points each. One point is added at each refresh.
The Screen Selector object is available from the Control Category of the Object
List window. This object is an enhanced version of the Screen Change pushbutton
in that it offers many more features and defaults with data from screens in the
project. This helps to save time by not having to create Screen change buttons for
each screen. This object may be edited to various colors and sizes.
The Line Graph object displays the values of up to 24 PLC address points. Up
to two address arrays can be displayed. The line is drawn in its entirety at each
refresh.
The Adjust Display Contrast object is used to allow the operator to adjust the Panel
Display Contrast. The default Display setting often works in most applications,
however lighting may vary based on the location of each application. In these
cases the operator can use this object to make adjustments. The current display
setting value will appear on the top of the button and will change as the arrow
keys are pressed. This button can be modified to various sizes.
The Analog Meter object is used to display the current value of a Tag Name.
The Function object is used to assign the panels function key buttons to a particular action as well as assigning the control of the LED On/Off status. When a
button has been assigned as a shift button, the then F1 through F7 will become
F8 through F14. The Function Object buttons will activate when the hardware
button is pressed or when the object is pressed on the screen. The object size
is restricted so that the keys will line up with the hardware function keys on the
panel.
The Bar Meter object is used to monitor up to two assigned Tag Names continuously. This object has various appearances depending upon the relative value of
the tags. The Bar Meter can be used to create digital versions of level, current,
and flow meters to name a few samples, or gauges that measure speed and
other measurable data.
Book 1 (14.2)
www.automationdirect.com/C-more-micro
C-more Micro Panels
eCK-77
Do-More
PLCs Overview
Do-More T1H
PLC
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
C-more Micro Programming Connections
C-more STN Micro Programming Connection
Using
the
C-more
Micro
Programming
Software
for
project
development, STN C-more Micro panels can be connected to a PC (personal
USB to RS-232 Programming Cable
computer) by using EA-MG-PGM-CBL, the USB-to-RS-232 cable assembly.
•C
onnect the USB programming cable (included) from a USB port type A on the PC to the USB
Assembly
type B port on the converter (included). Next connect the serial programming cable from the
converter’s RJ12 port to the panel’s RJ12 serial port. The panel receives power from the USB
port of the PC that it is connected to through the USB to RS-232 converter assembly.
USB Connectivity
USB
Cable
PC to Panel Programming
Cable Assembly
(Includes serial & USB cables)
p/n EA-MG-PGM-CBL
Serial
Cable
USB to RS232
Converter
Part No. EA-MG-PGM-CBL
C-more 3”
Micro-Graphic
Panel
User PC
NOTE: The TFT panels EA1-T4CL, EA1-T6CL, EA3-T6CL, EA3-T8CL and EA3-T10CL do
NOT use the EA-MG-PGM-CBL assembly. The TFT panels use a standard USB A-to-B
type cable such as USB-CBL-AB6. See below.
$43.00
USB to RS-232 Converter Specifications
Part Number
Hardware
EA-MG-PGM-CBL
USB Interface
USB Specification Rev. 1.1
Connector: USB Type B jack to accept USB Type B cable plug
RS-232 (EIA-232-E)
Connector: RJ12 phone jack 6p to accept RJ12 cable plug
115.2 kbps Maximum
Serial Interface
Baud Rate
Input Voltage
Power Consumption
Accessory Cables (included)
USB Cable
Serial Cable
Physical
5 VDC (Supplied thru serial interface cable.)
50 mA (Does not include power to panel and/or bezel.)
USB Type A plug to PC on one end, USB Type B plug to converter on other end, 0.30 m [1 foot] length (* Note)
RJ12 phone plug connectors on both ends, 2.0 m [6.56 feet] length (* Note)
2.559” (W) x 1.417” (H) x 0.886” (D)
[65.0 mm x 36.0 mm x 22.5 mm]
1.06 oz. [30 g]
Dimensions
Weight
Environmental
See Micro panel specifications at the beginning of this catalog section.
* Note: Maximum cable length for either the USB or serial cable should not exceed 2.0 m [6.56 feet] in length.
C-more TFT Micro Programming Connection
The C-more TFT Micro panels EA1-T4CL, EA1-T6CL, EA3-T6CL, EA3-T8CL and EA3-T10CL include an integral USB to serial
converter. It is programmed via any USB Type A to Type B cable.
When properly installed on your PC, the device driver will be assigned a communication port number and appear in Windows Device
Manager as a serial com port.
USB cable options for programming EA1-T4CL, EA1-T6CL, EA3-T6CL, EA3-T8CL and EA3-T10CL
Part Number
Description
Price
USB-CBL-AB3
Standard 3-ft. (0.9 m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch
panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.)
$7.50
USB-CBL-AB6
Standard 6-ft. (1.8 m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch
panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.)
$9.50
USB-CBL-AB10
Standard 10-ft (3 meter) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch
panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.)
$18.00
USB-CBL-AB15
Standard 15-ft. (4.6 m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch
panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.)
$22.50
Book 1 (14.2)
eCK-78
C-more Micro Panels
1-800-633-0405
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF