Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Panels Selection Guide Company Information Control Systems Overview C-more Micro Panels Part Number Description Price C-more Micro touch screen operator interface, 3.1 inch, STN LCD monochrome, 128 x 64 pixel display, selectable screen colors: red, green, amber, lime, or yellow, LED backlight, 5 user defined function keys, RS-232 (RJ12) port, display supports landscape mode(s), NEMA 4/4X, IP65, indoor use only. EA1-S3ML NonTouch EA1-S3ML-N C-more Micro non-touch operator interface, 3.1 inch, STN LCD monochrome, 128 x 64 pixel display, selectable screen colors: red, green, amber, lime, or yellow, LED backlight, 5 user defined function keys, RS-232 (RJ12) port, display supports landscape mode(s), NEMA 4/4X, IP65, indoor use only. $205.00 CLICK PLC Do-More PLCs Overview Do-More H2 PLC Do-More T1H PLC $161.00 DirectLOGIC PLCs Overview DirectLOGIC DL05/06 C-more Micro touch screen operator interface, 3.1 inch, STN LCD monochrome, 128 x 64 pixel display, selectable screen colors: white, pink1, pink 2, pink3 or red, high-contrast white LED backlight, 5 user defined function keys, RS-232 (RJ12) port, display supports landscape mode(s), NEMA 4/4X, IP65, indoor use only. EA1-S3MLW DirectLOGIC DL105 $205.00 DirectLOGIC DL205 DirectLOGIC DL305 EA1-S3MLW-N EA1-T4CL NonTouch C-more Micro non-touch operator interface, 3.1 inch, STN LCD monochrome, 128 x 64 pixel display, selectable screen colors: white, pink1, pink 2, pink3 or red, high-contrast white LED backlight, 5 user defined function keys, RS-232 (RJ12) port, display supports landscape mode(s), NEMA 4/4X, IP65, indoor use only. C-more Micro touch screen operator interface, 4.1 inch, TFT color LCD, 320 x 240 pixel display, 32K colors, LED backlight, 5 user defined function keys, RS-232 / RS-485 / 422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X, IP65, indoor use only. $161.00 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 $356.00 Universal Field I/O Software EA1-T6CL C-more Micro touch screen operator interface, 5.7 inch, TFT color LCD, 320 x 240 pixel display, 32K colors, LED backlight, 5 user defined function keys, RS-232 / RS-485 / 422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X, IP65, indoor use only. C-More HMI $432.00 C-More Micro HMI ViewMarq Industrial Marquees EA3-T6CL C-more Micro touch screen operator interface, 5.7 inch, TFT color LCD, 320 x 240 pixel display, 32K colors, LED backlight, 5 user defined function keys, RS-232 (RJ12) port, RS-232 / RS-485 / 422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X, IP65, indoor use only. $299.00 Other HMI Communications Appendix Book 1 Terms and Conditions EA3-T8CL C-more Micro touch screen operator interface, 8.4 inch, TFT color LCD, 800 x 600 pixel display, 32K colors, LED backlight, 7 user defined function keys, RS-232 (RJ12) port, RS-232 / RS-485 / 422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X, IP65, indoor use only. $749.00 EA3-T10CL C-more Micro touch screen operator interface, 10.4 inch, TFT color LCD, 800 x 600 pixel display, 32K colors, LED backlight, 7 user defined function keys, RS-232 (RJ12) port, RS-232 / RS-485 / 422 (15-pin D-sub) port, USB B port, display supports landscape/portrait mode(s), NEMA 4/4X, IP65, indoor use only. $899.00 Book 1 (14.2) www.automationdirect.com/C-more-micro C-more Micro Panels eCK-11 Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Panels Selection Guide C-more Micro Panel Accessories Part Number Description Price EA-MG-BZ1 8-button keypad bezel for C-more 3” Micro panels, with four arrow adjust keys, and ESCAPE, MENU, CLEAR and ENTER buttons. Helps to reduce screen wear in heavy-duty applications where operators can use the keypad. Designed for easy drop-in of the Micro panels. $64.00 20-button keypad bezel with numeric keypad for C-more 3” Micro panels, with four arrow adjust keys, and ESCAPE, MENU, CLEAR and ENTER buttons. Helps to reduce screen wear in heavy-duty applications where operators can use the keypad to enter numeric data. Designed for easy drop-in of the Micro panels. $87.00 EA-MG-P1 Optional DC Power Adapter for C-more 3” Micro panels. Required when using third party PLCs, or when using 24VDC power instead of the 5VDC supplied from the RJ12 connector of a Productivity Series, CLICK or Direct LOGIC PLC. $31.50 EA-MG-SP1 Optional Serial Port with DC Power Adapter for C-more 3” Micro panels. Serial port is a D-Sub 15-pin RS-232/RS-422/485 connector. Required when using RS422, RS485 or third party PLCs. $54.00 EA-COMCON-3 DSUB port adapter, 15-pin to 6-terminal RS-422/485, right angle connector, plugs into the 15-pin serial port on rear of touch panel to allow wire terminal connections for an RS-422/485 communication cable. Compatible with C-more EA7 series, EA9-T6CL(-R), and C-more Micro 4 or 6-inch panels. $42.00 EA-COMCON-3A DSUB port adapter, 15-pin to 6-terminal RS-422/485, straight connector, plugs into the 15-pin serial port on rear of touch panel to allow wire terminal connections for an RS-422/485 communication cable. Compatible with C-more EA9 series panels, C-more Micro EA3 series panels and EA1-S3x with EA1-MG-SP1. Not recommended with EA9-T6CL(-R) panels. $19.00 EA-MG6-BZ2 20-button keypad bezel with numeric keypad for EA1-T6CL panels being used in landscape (horizontal) mounted mode, with 2 arrow adjust keys, and ESCAPE, MENU, CLEAR and ENTER buttons. Helps to reduce screen wear in heavy-duty applications where operators can use the keypad to enter numeric data. Designed for easy drop-in of the EA1-T6CL panels. $107.00 EA-MG6-BZ2P 21-button keypad bezel with numeric keypad for EA1-T6CL panels being used in Portrait (vertical) mounted mode, with 2 arrow adjust keys, and ESCAPE, MENU, CLEAR and ENTER buttons. Helps to reduce screen wear in heavy-duty applications where operators can use the keypad to enter numeric data. Designed for easy drop-in of the EA1-T6CL panels. $79.00 EA-MG-COV-CL Optional clear screen overlay used to protect 3” displays from minor scratches and wear. Package contains five (5) clear screen overlays. $35.50 EA-4-COV2 Optional clear screen overlay used to protect 4” displays from minor scratches and wear. Package contains three (3) clear screen overlays. $33.50 EA-6-COV2 Optional clear screen overlay used to protect 6” displays from minor scratches and wear. Package contains three (3) clear screen overlays. $37.00 EA-8-COV2 Optional clear screen overlay used to protect 8” displays from minor scratches and wear. Package contains three (3) clear screen overlays. $40.00 EA-10-COV2 Optional clear screen overlay used to protect 10” displays from minor scratches and wear. Package contains three (3) clear screen overlays. $45.50 EA-MG-BZ2 Book 1 (14.2) eCK-12 C-more Micro Panels 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. C-more 4” Micro Panels Overview Overview C-more 4” Micro panel is a full color, TFT model that offers touch screen capability and customizable graphics! The 4” panel mounts in a standard 1/4 DIN cutout. EA1-T4CL In addition to the simple panel configuration software, a very helpful feature is the built-in project simulator. The project simulator allows you to view your project on the PC screen as it would appear on the panel and to test all your screens before downloading the project to the panel. You can simulate your entire project at any stage of development and even simulate the function keys and keypad bezel. $356.00 NOTE: EA1-T4CL requires Software and Firmware Version 3.00 or later. Available for free download at www.automationdirect.com. Getting started Installing the software and configuring the C-more 4” Micro panel is simple. You will need the following to successfully connect and configure a project for the panel: • C-more 4” Micro panel • C-more Micro Programming Software EA-MGPGMSW (Downloadable version available from the AutomationDirect web site at no charge.) • C-more Micro USB Programming Cable such as USB-CBLAB6, used to connect between a PC and the Micro panel’s built-in programming port. The panel will operate in Low-Power mode when powered by the PC and the screen brightness is diminished. • Power source – An external Class 2, 12-24 VDC power source is required for normal High-Power operation. Recommended power supplies are AutomationDirect part numbers PSC-24-015 or PSC-24-030. • Personal computer – to run the C-more Micro programming software • Communications Cable (serial) – to connect the C-more Micro panel to your PLC or other controller with which the panel will communicate. Drivers for your Controller C-more 4” Micro panels have the following drivers available for connection to Productivity Series, CLICK, DirectLOGIC and many other devices: • AutomationDirect Productivity Series • AutomationDirect Do-more • AutomationDirect CLICK (Modbus) • DirectLOGIC K-sequence, DirectLOGIC DirectNET, DirectLOGIC Modbus (Koyo Addressing) • Modbus RTU • Allen Bradley DF1 Full Duplex, Allen Bradley DF1 Half Duplex, Allen Bradley PLC5 DF1, AB DH485 • Omron Host Link (C200 Adapter, C500) Omron FINS serial (CJ1, CS1) • GE SNPX (90/30, 90/70, Micro 90, VersaMax Micro) • Mitsubishi Melsec FX • Siemens PPI • Entivity Modbus RTU • AutomationDirect GS Drives • AutomationDirect SOLO Temperature Controllers • Mitsubishi Q/QnA Bitmaps Features • 320 X 240 pixel graphical display supports bitmaps • Use bitmap images of pushbuttons, switches, indicators, your company logo • Use provided library of bitmaps • Create your own library of bitmaps Text - 40 lines • 40 lines by 80 characters of static text in Landscape Orientation • 54 lines by 59 characters of static text in Portrait Orientation • Look up text, scroll up to 128 characters • 30 lines by 40 characters of dynamic text, embedded variables, on/off phrases, scroll up to 40 characters • Scroll text object with up to 128 characters Beep • Beep to indicate an alarm • Beep for a special message • Beep to verify when button is pressed Bar graphs • Line, vertical, horizontal, skinny, fat, multiple Data entry • Pop-up numeric key pad on the screen • Increment/decrement a value by touching arrows Recipes Each recipe button transfers up to 99 values from PLC source registers to PLC destination registers and/or from the recipe table to PLC destination registers. 32K Colors The TFT panel has a palette of 32K colors available to make full use of color for objects and bitmaps as well as backgrounds. Up to 999 Screens C-more Micro supports up to 999 screens. Screen quantity is limited by memory usage which is determined by the total bitmaps, objects, etc. that are used. Book 1 (14.2) eCK-36 C-more Micro Panels 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. C-more 4” Micro Panels Overview Company Information Control Systems Overview C-more 4” TFT Micro Panel Part Number Description Price 4-inch C-more Micro Touch Panel with TFT Color LCD, 320 x 240 dot, 32,768 color display with LED backlight. 5 user-defined function keys with LED indicators. Two built-in ports (USB Type-B port and 15-pin D-sub RS-232/422/485 port). Display supports Portrait and Landscape modes. NEMA 4/4X, IP65 (when mounted correctly; for indoor use only). EA1-T4CL CLICK PLC Do-More PLCs Overview $356.00 Do-More H2 PLC Do-More T1H PLC Note: Software and Firmware Version 3.00 or later is required with model EA1-T4CL. Available for free download at www.automationdirect.com. Description Price EA-MG-PGMSW C-more Micro Windows-based programming software for C-more EA1 and EA3 series panels. Package includes software CD. Requires USB port connection from PC to C-more Micro panel. Cables sold separately. Downloadable version available from the Web site at no charge. USB-CBL-AB3 USB-CBL-AB6 USB-CBL-AB10 USB-CBL-AB15 The C-more Micro TFT panel requires a USB A-to-B type cable to connect a personal computer to the panel for programming. (Note: The TFT panel includes a built-in USB to serial converter and the USB driver will appear as a COM port to the PC when properly installed. The USB port supplies 5VDC to the TFT panel so that no external power supply is required for programming.) DirectLOGIC DL205 DirectLOGIC DL305 $25.00 $7.50 $9.50 $18.00 $22.50 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 Universal Field I/O C-more 4” Micro Panel Accessories Part Number DirectLOGIC DL05/06 DirectLOGIC DL105 C-more Micro Programming Software Part Number DirectLOGIC PLCs Overview Description Price Software C-More HMI EA-ADPTR-4 EA-COMCON-3 DSUB PLC serial communications port adapter, 15-pin 90-degree. Compatible with C-more EA7 series, EA9-T6CL(-R) and C-more Micro 4 or 6-inch panels. DSUB port adapter, 15-pin to 6-terminal RS-422/485, right angle connector, plugs into the 15-pin serial port on rear of touch panel to allow wire terminal connections for an RS-422/485 communication cable. Compatible with C-more EA7 series, EA9-T6CL(-R), and C-more Micro 4 or 6-inch panels. $39.00 C-More Micro HMI ViewMarq Industrial Marquees $42.00 Other HMI Communications Appendix Book 1 EA-4-COV2 Optional clear screen overlay used to protect C-more 4” Micro displays from minor scratches and wear. Package contains 3 clear screen overlays. $33.50 For a list of supported protocols and cabling options refer to the C-more Micro Protocols and cabling chart starting on page CK-71. Book 1 (14.2) www.automationdirect.com/C-more-micro C-more Micro Panels eCK-37 Terms and Conditions Prices as of April 15, 2015. Check Web site for most current prices. C-more 4” & 6” Micro PLC Connections Cabling requirements Do-More H2 PLC Expansion Connector R**. 1 2 3 4 5 MODEL:EA1-T4CL USB Type B Programming Port R INPUT:12-24V 0.19-0.38A Class2 Date code:9048 MADE IN CHINA 7M17 IND.CONT.EQ. Signal Pin 1 Frame GND 6 LE 11 TXD+ (422/485) 2 TXD (232C) 7 CTS (232C) 12 TXD– (422/485) 3 RXD (232C) Signal Pin Signal 8 RTS (232C) 13 Term. Resistor 4 Supplies +5VDC 9 RXD+ (422/485) 14 do not use 5 Logic GND 10 RXD– (422/485) 15 do not use RS-232/422/485 PLC 15-pin serial communications Port2 DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL205 EA3-T6CL DirectLOGIC DL305 DirectLOGIC DL405 Expansion Connector RJ12 serial communications Port1 USB Type B Programming Port Productivity Controller Overview Productivity 3000 8 1 15 9 Universal Field I/O PLC 15-pin serial communications Port2 Software Signal Pin Pin Pin Signal Pin Signal 1 Frame GND 6 LE 11 TXD+ (422/485) 2 TXD (232C) 7 CTS (232C) 12 TXD– (422/485) 3 RXD (232C) 8 RTS (232C) 13 Term. Resistor 4 Supplies +5VDC 9 RXD+ (422/485) 14 do not use 5 Logic GND 10 RXD– (422/485) 15 do not use Signal 1 Logic GND 2 not used 3 RXD (232C) 6 5 4 3 2 1 • • • • • • • Pin + - • Do-More T1H PLC EA1-T4CL+094018001 Drivers for your Controller • • CLICK PLC Do-More PLCs Overview The EA1-T4CL and EA1-T6CL can only communicate to a controller through the 15-pin serial Port2. Port 2. EA3-T6CL can communicate to a controller through the 15-pin or the RJ12 serial ports. The USB port is for programming only. AutomationDirect Productivity Series AutomationDirect Do-more AutomationDirect CLICK (Modbus) DirectLOGIC K-sequence, DirectLOGIC DirectNET, DirectLOGIC Modbus (Koyo Addressing) Modbus RTU Allen Bradley DF1 Full Duplex, Allen Bradley DF1 Half Duplex, Allen Bradley PLC5 DF1, AB DH485 Omron Host Link (C200 Adapter, C500) Omron FINS serial (CJ1, CS1) GE SNPX (90/30, 90/70, Micro 90, VersaMax Micro) Mitsubishi Melsec FX Siemens PPI Entivity Modbus RTU AutomationDirect GS Drives AutomationDirect SOLO Temperature Controllers Mitsubishi Q/QnA Control Systems Overview Communication Ports EA1-T4CL The C-more 4” and 6” Micro panels can communicate through the built-in 15-pin serial port (Port2) via RS-232, RS-422 and RS-485 using these cables. • EA-2CBL — connects to CLICK, P3-550, DL05, DL105, DL205, D3-350 and D4-450 phone jack. • EA-2CBL-1 — connects to D2-250, D250-1, D2-260, DL06 VGA connector. • • • • Company Information 4 TXD (232C) 5 Receives 5VDC 6 Logic GND C-More Micro HMI RS-232 RS-232/422/485 C-More HMI ViewMarq Industrial Marquees EA1-T6CL Other HMI Communications C-more Micro Port 1 to CLICK PLC Port 2 Port 2 PLC 15-pin serial communications Port2 Port 1 DV-1000CBL serial cable 8 1 15 9 Pin Signal Pin 1 Frame GND 6 LE 11 TXD+ (422/485) 2 TXD (232C) 7 CTS (232C) 12 TXD– (422/485) 3 RXD (232C) Signal Pin Signal 8 RTS (232C) 13 Term. Resistor 4 Supplies +5VDC 9 RXD+ (422/485) 14 do not use 5 Logic GND 10 RXD– (422/485) 15 do not use RS-232/422/485 Book 1 (14.2) www.automationdirect.com/C-more-micro Appendix Book 1 Terms and Conditions Expansion Connector C-more 6” Micro Panel CLICK PLC USB Type B Programming Port C-more Micro Panels eCK-59 Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Communication Protocols & Cabling Chart Controller Compatibility & Connection Chart PLC Family CLICK CPU all versions Analog CPU’s Productivity Series Do-more Entivity all versions Protocol(s) Supported Port 1 RJ12 - 6 pin Port 2 RJ12 - 6 pin Modbus (CLICK) Port3 Term block 3-pin RS-232 RJ12 - 6 pin RS-485 Port Term block 3-pin all versions RS-232 RJ12 - 6 pin H2-SERIO RS-232 RJ12 - 6 pin H2-SERIO-4 RS-232 RJ12 - 6 pin H2-WinPLC RS-232 RJ12 - 6 pin H2-SERIO RS-232 RJ12 - 6 pin H2-SERIO-4 RS-232 RJ12 - 6 pin all versions Using panel’s RJ12 Port1** Port 1 RJ12 - 6 pin Port 2 RJ12 - 6 pin D0-DCM Port 2 DB15HD (female) Productivity3000 Serial (P3-550) Do-more Serial, K-sequence, Modbus RTU D0-CBL RS-232 N/A D0-CBL RS-232 Productivity3000 Serial (P3-550) Do-more Serial, K-sequence, Modbus RTU all versions Port 2 DB15HD (female) Port 1 RJ12 - 6 pin Do-More T1H PLC * See Note RS-485 DirectLOGIC PLCs Overview EA-2CBL RS-232 * See Note RS-485 EA-2CBL RS-232 D0-CBL RS-232 Entivity Modbus RTU Modbus RTU EA-2CBL RS-232 K-sequence, Direct NET, Modbus RTU D0-CBL RS-232 K-sequence, Direct NET, Modbus RTU EA-2CBL RS-232 EA-2CBL RS-232 D0-CBL RS-232 K-sequence, Direct NET, Modbus RTU D0-CBL + FA-15HD RS-232 K-sequence, Direct NET, Modbus RTU EA-2CBL-1 RS-232 Modbus RTU * See Note RS-485 Modbus only K-sequence, Direct NET, Modbus RTU K-sequence, Direct NET, Modbus RTU D0-CBL + FA-15HD RS-232 K-sequence K-sequence, Direct NET, Modbus RTU D0-CBL + FA-15HD RS-232 D0-CBL RS-232 EA-2CBL-1 RS-232 DirectLOGIC DL105 DirectLOGIC DL205 Productivity Controller Overview Productivity 3000 Universal Field I/O Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 EA-2CBL-1 RS-232 * See Note RS-422 Modbus RTU * See Note RS-485 Modbus only K-sequence EA-2CBL RS-232 **Note: These charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options. PLC Compatibility & Connection Chart continued on next page. Book 1 (14.2) C-more Micro Panels DirectLOGIC DL405 * See Note RS-485 Modbus only * Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user can use to construct their own cables. The manual is available for download at www.automationdirect.com. www.automationdirect.com/C-more-micro DirectLOGIC DL05/06 * See Note RS-422 EA-2CBL RS-232 D0-CBL RS-232 K-sequence, Direct NET, Modbus RTU * See Note RS-422 EA-2CBL RS-232 D0-CBL RS-232 Port 1 RJ12 - 6 pin D0-DCM Do-More H2 PLC EA-2CBL RS-232 Entivity Modbus RTU Modbus RTU Modbus RTU Direct LOGIC DL06 Direct LOGIC DL105 Port 2 DB15HD (female) Modbus (CLICK) Do-More PLCs Overview DirectLOGIC DL305 Port 1 RJ12 - 6 pin all versions D0-CBL RS-232 Using panel’s Port2** DB 15-pin - female Protocol(s) Components & Supported Network Type N/A Port 1 RJ12 - 6 pin Direct LOGIC DL05 Components & Network Type Control Systems Overview CLICK PLC C-more Micro Panel PLC Port & Type Company Information eCK-71 Terms and Conditions Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Communication Protocols & Cabling Chart (cont’d) Controller Compatibility & Connection Chart PLC C-more Micro Panel Family CPU Port & Type D2-230 D2-240 Using panel’s RJ12 port 1** Protocol(s) Supported Components & Network Type Port 1 RJ12 - 6 pin K-sequence D0-CBL RS-232 Port 1 RJ12 - 6 pin K-sequence Port 2 RJ12 - 6 pin K-sequence, Direct NET, D0-CBL RS-232 Port 2 DB15HD (female) K-sequence, Direct NET, Modbus RTU D0-CBL + FA-15HD RS-232 D2-260 Port 2 DB15HD (female) K-sequence K-sequence, Direct NET, K-sequence, Direct NET, Modbus RTU EA-2CBL RS-232 EA-2CBL-1 RS-232 * See Note RS-422 EA-2CBL RS-232 K-sequence, Direct NET, Modbus RTU K-sequence, Direct NET, Modbus RTU EA-2CBL RS-232 EA-2CBL RS-232 D0-CBL RS-232 Port 1 RJ12 - 6 pin Direct LOGIC DL205 K-sequence D0-CBL RS-232 D2-250-1 D2-250-1 Using panel’s Port2** DB 15-pin - female Protocol(s) Components & Supported Network Type D0-CBL + FA-15HD RS-232 EA-2CBL-1 RS-232 * See Note RS-422 Modbus RTU * See Note RS-485 Modbus only EA-4CBL-2 RS-232 D2-DCM Port 1 DB 25 pin (female) K-sequence, Direct NET, Modbus RTU *See Note RS-232 Direct NET WINPLC Port 1 RJ12 - 6 pin Modbus RTU D0-CBL RS-232 Modbus RTU EA-2CBL RS-232 D3-330 or D3-340 D3-232-DCU DB 25 pin (female) Direct NET D0-CBL +FA-CABKIT RS-232 Direct NET EA-4CBL-2 RS-232 Direct NET *See Note RS-422 D3-422-DCU DB 25 pin (female) D3-340 Direct LOGIC DL305 D3-350 D3-DCM D3-350 only N/A Port 1 RJ11 - 4 pin Direct NET Port 2 RJ11 - 4 pin Direct NET, Modbus RTU Port 1 RJ12 - 6 pin K-sequence, Direct NET D0-CBL RS-232 K-sequence, Direct NET Port 2 DB 25 pin (female) K-sequence, Direct NET, Modbus RTU *See Note RS-232 K-sequence, Direct NET, Modbus RTU Port 1 DB 25 pin (female) K-sequence, Direct NET, Modbus RTU *See Note RS-232 Direct NET OP-3CBL-1 RS-232 Direct NET Direct NET, Modbus RTU * See Note RS-422 EA-3CBL RS-232 EA-2CBL RS-232 EA-4CBL-2 RS-232 *See Note RS-422 EA-4CBL-2 RS-232 *See Note RS-422 * Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user can use to construct their own cables. The manual is available for download at www.automationdirect.com. **Note: T hese charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options. PLC Compatibility & Connection Chart continued on next page. Book 1 (14.2) eCK-72 C-more Micro Panels 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Communication Protocols & Cabling Chart (cont’d) Company Information Control Systems Overview CLICK PLC Controller Compatibility & Connection Chart PLC Family Do-More PLCs Overview C-more Micro Panel CPU Port & Type Using panel’s RJ12 port 1** Using panel’s Port2** DB 15-pin - female Protocol(s) Components & Supported Network Type Protocol(s) Supported Components & Network Type Port 0 DB 15 pin (female) K-sequence D0-CBL & FA-CABKIT RS-232 K-sequence Port 1 DB 25 pin (female) K-sequence, Direct NET D0-CBL & FA-CABKIT RS-232 K-sequence, Direct NET EA-4CBL-2 RS-232 *See Note RS-422 K-sequence D0-CBL & FA-CABKIT RS-232 K-sequence EA-4CBL-1 RS-232 D4-430 Port 0 DB 15 pin (female) D4-440 Direct LOGIC DL405 D4-450 EA-4CBL-1 RS-232 Port 1 DB 25 pin (female) K-sequence, Direct NET D0-CBL & FA-CABKIT RS-232 K-sequence, Direct NET EA-4CBL-2 RS-232 *See Note RS-422 Port 0 DB 15 pin (female) K-sequence D0-CBL & FA-CABKIT RS-232 K-sequence EA-4CBL-1 RS-232 K-sequence, Direct NET, Modbus RTU EA-4CBL-2 RS-232 *See Note RS-422 K-sequence, Direct NET, Modbus RTU *See Note RS-422 K-sequence, Direct NET EA-2CBL RS-232 Port 1 DB 25 pin (female) D0-CBL & FA-CABKIT RS-232 K-sequence, Direct NET, Modbus RTU Port 3 DB 25 pin (female) N/A D0-CBL RS-232 Port 2 RJ12 - 6 pin K-sequence, Direct NET D4-DCM Port 1 DB 25 pin (female) K-sequence, Direct NET, Modbus RTU SOLO N/A Data +/terminals N/A SOLO Temperature Controller *See Note RS-485 GS Drives N/A RS-485 Interface N/A GS Drives Serial GS Drives TCP/IP (GS-EDRV) *See Note RS-485 *See Note RS-232 Direct NET EA-4CBL-2 RS-232 *See Note RS-422 * Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user can use to construct their own cables. The manual is available for download at www.automationdirect.com. **Note: These charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options. Do-More T1H PLC DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL205 DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 Universal Field I/O Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions PLC Compatibility & Connection Chart continued on next page. Book 1 (14.2) www.automationdirect.com/C-more-micro Do-More H2 PLC C-more Micro Panels eCK-73 Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Communication Protocols & Cabling Chart (cont’d) Controller Compatibility & Connection Chart PLC C-more Micro Panel Family CPU Allen-Bradley MicroLogix 1000, 1100, 1200, 1400, 1500 Allen-Bradley SLC500 Port & Type Using panel’s RJ12 port 1** Protocol(s) Supported Components & Network Type Using panel’s Port2** DB 15-pin - female Protocol(s) Components & Supported Network Type 8-pin mini-din port DF1 Full Duplex DF1 Half Duplex EA-MLOGIX-CBL RS-232 RJ45 8-pin phone plug DH485/AIC/AIC+ EA-DH485-CBL RS-232 5/03, 5/04, 5/05 9-pin D-sub port DF1 Full Duplex DF1 Half Duplex EA-SLC-232-CBL RS-232 5/01, 5/02, 5/03 RJ45 8-pin phone plug DH485/AIC/AIC+ EA-DH485-CBL RS-232 Allen-Bradley ControlLogix Allen-Bradley CompactLogix Allen-Bradley FlexLogix all 9-pin D-sub port DF1 Full Duplex DF1 Half Duplex EA-SLC-232-CBL RS-232 all 9-pin D-sub port DF1 Full Duplex DF1 Half Duplex EA-SLC-232-CBL RS-232 all 9-pin D-sub port DF1 Full Duplex DF1 Half Duplex EA-SLC-232-CBL RS-232 Allen-Bradley PLC5 25-pin D-sub port DF1 Full Duplex all EA-PLC5--232-CBL RS-232 RJ45 8-pin phone plug DH485/AIC/AIC+ EA-DH485-CBL RS-232 90/30 GE Micro 90, VersaMax Micro Melsec FX Series Mitsubishi Q / QnA C200 (Adapter), C500 Omron Modicon Siemens CJ1, CS1, CQM1, CPM1, CPM2, C200 984 CPU, Quantum 113 CPU, AEG Modicon Micro Series 110 CPU S7-200 CPU EA-90-30-CBL RS-422 15-pin D-sub port RJ45 Port 1 15-pin D-sub port Port 2 25-pin D-sub port 8-pin mini-din port 9-pin D-sub port 6-pin mini-din port SNPX N/A *See Note RS-232 EA-90-30-CBL RS-422 CPU Direct Q / QnA EA-MITSU-CBL RS-422 EA-MITSU-CBL-1 RS-422 *See Note RS-232 *See Note RS-232 25-pin D-sub port Host Link EA-OMRON-CBL RS-232 9-pin D-sub port FINS *See Note RS-232 varies Modbus RTU *See Note RS-232 9-pin D-sub port 0 or 1 PPI *See Note RS-485 * Note: S ee the C-more Micro Hardware User Manual (P/N: EA3-USER-M), Chapter 6: PLC Communications, for wiring diagrams that the user can use to construct their own cables. The manual is available for download at www.automationdirect.com. **Note: T hese charts apply to all current C-more Micro panels except 3” models. The 3” panels include only the RJ12 Port1. Optional accessory for 3” models EA-MG-SP1 provides the DB 15-pin Port2. 3” models may be powered through Port1 when connected to an AutomationDirect PLC which provides 5VDC using a cable such as DV-1000CBL that properly carries the 5VDC. All other panels require an external power supply. Refer to the 3” Communication and Cabling Chart starting on page CK-24 for cabling options. Book 1 (14.2) eCK-74 C-more Micro Panels 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. C-more 8” & 10” Micro Communication Cables and Cable Kits Cable Description Cable Part Number Control Systems Overview CLICK PLC Price Cables used with RJ-12 RS-232 serial Port1 AutomationDirect Productivity Series, Do-more, CLICK, Direct LOGIC PLC RJ-12 port, DL05, DL06, DL105, DL205, D3-350, D4-450 & H2-WinPLC (RS-232C) 3.66m (12ft) cable length Direct LOGIC (VGA Style) 15-pin port, DL06, D2-250 (250-1), D2-260 (RS-232C) Use with D0-CBL cable. Company Information Do-More PLCs Overview D0-CBL D0-CBL Do-More H2 PLC $19.00 FA-15HD Do-More T1H PLC $8.00 Direct LOGIC PLC 15-pin D-sub port, DL405 (RS-232C) Use with D0-CBL cable. FA-CABKIT $40.00 Direct LOGIC PLC RJ-11 port, D3-340 (RS-232C) 2m (6.56 ft) cable length OP-3CBL-1 $6.00 OP-3CBL-1 FA-15HD DirectLOGIC DL05/06 DirectLOGIC DL105 Cables used with 15-pin RS-232/422/485 serial Port2 AutomationDirect Productivity Series, Do-more, CLICK, Direct LOGIC PLC RJ-12 port, DL05, DL06, DL105, DL205, D3-350, D4-450 & H2-WinPLC (RS-232C) 3m (9.8 ft) cable length EA-2CBL Direct LOGIC (VGA Style) 15-pin port, DL06, D2-250 (250-1), D2-260 (RS-232C) 3m (9.8 ft) cable length EA-2CBL-1 $20.00 Direct LOGIC PLC RJ-11 port, D3-340 (RS-232C). 3m (9.8 ft) cable length EA-3CBL $20.00 Direct LOGIC DL405 PLC 15-pin D-sub port, DL405 (RS-232C). 3m (9.8 ft) cable length EA-4CBL-1 $20.00 Direct LOGIC PLC 25-pin D-sub port, DL405, D3-350, DL305 DCU and all DCM’s (RS-232C). 3m (9.8 ft) cable length EA-4CBL-2 $20.00 Allen-Bradley MicroLogix 1000, 1100, 1200, 1400 & 1500 (RS-232C) 3m (9.8 ft) cable length EA-MLOGIX-CBL Allen-Bradley SLC 5-03/04/05, ControlLogix, CompactLogix, FlexLogix DF1 port (RS-232C) 3m (9.8 ft) cable length EA-SLC-232-CBL Allen-Bradley PLC-5 DF1 port (RS-232C) 3m (9.8 ft) cable length EA-PLC5-232-CBL $20.00 Allen-Bradley MicroLogix, SLC-5-01/02/03, PLC5 DH485 port (RS-232C) 3m (9.8 ft) cable length EA-DH485-CBL $20.00 GE 90/30 and 90/70, Micro 90, VersaMax Micro (Port 2) 15-pin D-sub port (RS-422A) 3m (9.8 ft) cable length EA-90-30-CBL $20.00 MITSUBISHI FX Series 25-pin port (RS-422A) 3m (9.8 ft) cable length EA-MITSU-CBL $20.00 DirectLOGIC DL205 FA-CABKIT $20.00 DirectLOGIC DL305 DirectLOGIC DL405 EA-2CBL EA-2CBL-1 Productivity Controller Overview Productivity 3000 Universal Field I/O $30.00 Software $20.00 EA-3CBL EA-4CBL-1 EA-MITSU-CBL-1 $20.00 OMRON Host Link C200 Adapter, C500 (RS-232C) 3m (9.8 ft) cable length EA-OMRON-CBL $20.00 C-More Micro HMI ViewMarq Industrial Marquees Communications EA-MLOGIX-CBL EA-4CBL-2 EA-PLC5-232-CBL EA-MITSU-CBL EA-MITSU-CBL-1 EA-SLC-232-CBL EA-OMRON-CBL Book 1 (14.2) www.automationdirect.com/C-more-micro Appendix Book 1 Terms and Conditions EA3-T8CL and EA3-T10CL cannot be powered by a PLC and cannot communicate with a PLC through the USB Programming Port. EA-90-30-CBL C-More HMI Other HMI MITSUBISHI FX Series 8-pin mini-DIN (RS-422A) 3m (9.8 ft) cable length EA-DH485-CBL DirectLOGIC PLCs Overview C-more Micro Panels eCK-75 Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Programming Software FREE software! C-more Micro Programming Software can be downloaded at no charge or a CD version may be purchased by ordering EA-MG-PGMSW. The software requires a USB port on your PC to connect to the C-more Micro panel. Software Help Files are included in the download. This software programs all the C-more Micro panels (does not program the C-more 6” through 15” touch panels). Note: This software is used to program C-more Micro panels only. Part Numbers: EA1-S3ML, EA1-S3ML-N, EA1-S3MLW, EA1-S3MLW-N, EA1-T4CL, EA1-S6ML, EA1-S6MLW, EA1-T6CL, EA3-T6CL, EA3-T8CL, EA3-T10CL C-more Micro Programming Software is a spin-off of its powerful sibling C-more Touch Panel. It offers very high end features designed to reduce your configuration time. Simply drag and drop the objects from the object list (right side of screen) onto the screen construction area. Then configure your PLC tags and click on the objects you wish to use. Use the built-in simulator to review your work on your PC before ever downloading your project! The time saving benefits of the C-more Micro configuration software could easily pay for the panel. Check out www.CmoreMicro.com to download a free version. Thumbnail project preview pane NOTES: Software and Firmware Version 3.5 or later is required with model EA3-T6CL. Software and Firmware Version 3.5 or later is required with models EA3-T8CL and EA3-T10CL. Software and Firmware Version 3.0 or later is required with model EA1-T4CL. Software and Firmware Version 2.5 or later is required with model EA1-T6CL. Software and Firmware Version 2.0 or later is required with models EA1-S6ML and EA1-S6MLW. Software and Firmware Version 1.5 or later is required with models EA1-S3MLW and EA1-S3MLW-N. Available for free download at www.automationdirect.com. Built-in project simulator • Runs your project on your PC • Test all of your screens before downloading • Time savings pays for the panel Built-in user object/ screen libraries Save time by re-using your objects and screens. custom • Version 2.5 or later - Simulate function keys and keypad bezel. Scrolling object selection window Lets you find the object you want fast. Just drag and drop it on the screen. Helps keep track of multi-screen projects. PC requirements Scrolling help window Following are the minimum system requirements for running C-more Micro Gives you helpful information on each object Programming Software, EA-MG-PGMSW, on a PC: •O perating System - Windows® XP Professional Edition Service Pack 2, Windows® 7 (32 or 64 bit) or Windows 8 (32 or 64 bit) • 150 MB free hard-disk space •C D-ROM or DVD drive for installing software from the CD, or internet access to download free programming software •U SB port to use with the correct Programming Cable Assembly for project transfer from the programming software to the panel Book 1 (14.2) eCK-76 C-more Micro Panels 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Programming Software Company Information C-more Micro Panel Objects Object Graphic Object Graphic Control Systems Overview CLICK PLC Shape objects, just like with drawing tools, allow the user to insert shapes, such as a straight line, circle, or rectangle drawing into a project. When a Shape is inserted into a project, a window opens to allow the user to setup all available parameters for the Line object. Some of the uses for Shape Objects include but are not limited to adding callouts, pointers, or indicators. The Bitmap Button object offers the ability to use a Bitmap graphic to perform the functions of a Button. This allows users to create their own graphics and implement them within the software project. The Bitmap Button object can be used to activate or deactivate components assigned to a Discrete Tag Name. The C-more Micro display only supports two colors, black and white. The Frame object allows the user to insert a Frame to the project that can be used to Frame other objects. Some of the uses for Frame object include but are not limited to graphically separating objects for different operations that may appear on one screen and emphasizing pushbuttons or other objects that may require more attention by the operator. The Static Bitmap offers the ability to display a Bitmap graphic on any screen. The Static Bitmap does not change state. Refer to the Dynamic Bitmap Object if you require the graphic object to change state based on a Tag Value in your PLC. The dialog box for a “Static Bitmap” object allows you to “read from disk” and select a graphic file for import. Graphics must be in one of the following formats: .BMP .WMF .JPG .JPEG Do-More H2 PLC The Pushbutton object is available from the Button Category of the Object List window. The Pushbutton object is an electronic version of a typical Pushbutton normally found on control panels. The Pushbutton object can be used to activate or deactivate components assigned to a Discrete Tag Name. Recipe objects make it easy to make a large number of tag changes with the push of a single button. Create Recipes with up to 99 entries, and multiple sets of values. Then just push a button to load an entire set of values into the group of recipe tags. DirectLOGIC PLCs Overview The Switch object is an electronic version of a typical Switch that normally can be found on control panels. The Switch object can be used to activate or deactivate components assigned to a Discrete Tag Name. The Dynamic Bitmap object offers the ability to make an object using two different Bitmap graphics that will display one graphic when the Tag is On and a different graphic when the Tag is Off. Use your own bitmap designs or use some of the bitmaps provided with the software that are located in the User Graphic Library. The Indicator Button object is available from the Button Category of the Object List window. The Indicator Button object is an electronic version of a typical Indicator Button normally found on control panels. The Indicator Button is a combination of a Pushbutton and an Indicator Light. The Indicator Button can be used to activate or deactivate components assigned to a Discrete Tag Name. The Static Text object is used to display a Frame with a personalized Message. This Frame and Message can be placed on any screen and any location within the screen. The Indicator Light object is an electronic version of a typical Indicator Light normally found on industrial control panels. The Indicator Light can be configured to display the status of the assigned Discrete Tag Name. The Lookup Text object is used to display a Frame with a personalized Message. This Frame and Message can be placed on any screen and any location within the screen. The object is always displayed like a sign but is configured to display only the message prompted by an assigned Tag Name. Messages are retrieved from a Message Database which is configured by the user with text defined by the user. The Lookup Text Object will scroll text up to 128 characters. The Graphic Indicator Light object is a more enhanced version of the “Indicator Light Object” that allows the user to choose more detailed graphics to display the status of a tag. This object is an electronic version of a typical Indicator Light normally found on industrial control panels. The Indicator Light can be configured to display the status of the assigned Discrete Tag Name. The Dynamic Text object is used to display text that is retrieved from data stored in a Tag. The Tag Name is assigned to registers in the PLC that contain set character data. The data can be stored in the PLC in ASCII format and may include information such as machine numbers, locations, part numbers, and such. The Message can be configured to be visible (Trigger) when an associated Tag Name is On or Off. This object can be placed on any screen and any location within the screen. The Dynamic Text Object will scroll text up to 40 characters. The Numeric Display consists of a frame that displays a real-time numeric value according to the value of data received from an assigned Tag Name. The Numeric Display supports numeric Signed Decimal, Unsigned Decimal, BCD, and Floating Point data types with up to 11 digits, including decimal point. User Defined Alpha Numeric Prefix and Suffix values are also supported. The Scroll Text object is available from the Text Category of the Object List window. The Scroll Text object is an electronic version of a marquee. It is similar to the Static Text Object. If the text in the object does not fit in the window, it will scroll from right to left across the window. The Scroll Text object does not require a Tag Name assignment. The Scroll Text Object has a maximum character limit of 128 characters. The Numeric Entry object is used to enter a value from your Panel to a PLC Register. This object, when selected, opens a Numeric Keypad that allows the user to enter a new value that will be written to the assigned Tag Name. The Numeric Entry supports numeric Signed Decimal, Unsigned Decimal, BCD, and Floating Point data types with up to 11 digits, including decimal points. User Defined Alpha Numeric Prefix and Suffix values are also supported. The Text Entry object is used to enter an ASCII string. Two entry options allow use of an on-screen keypad or the hardware function keys to enter characters. The Increment/Decrement Value object is used to add or subtract a value by pressing a button on the Panel. Basically the object uses two Tags, one to read a value from and another to write a modified value to. The Increment/Decrement Value supports numeric Signed Decimal, Unsigned Decimal, BCD, and Floating Point data types with up to 11 digits, including decimal points. The Increment and decrement values are also user selectable. The Screen Change Pushbutton object is available from the Control Category of the Object List window. The Screen Change Pushbutton object is a pushbutton that can be configured to activate another screen in the project. This object may be edited to various colors and sizes. Users can configure the button to activate the Power-Up screen, Forward Screen, Previous Screen, or any one of the project screens. The Real Time Graph object displays the value stored in up to two PLC tags, over a history of up to 24 points each. One point is added at each refresh. The Screen Selector object is available from the Control Category of the Object List window. This object is an enhanced version of the Screen Change pushbutton in that it offers many more features and defaults with data from screens in the project. This helps to save time by not having to create Screen change buttons for each screen. This object may be edited to various colors and sizes. The Line Graph object displays the values of up to 24 PLC address points. Up to two address arrays can be displayed. The line is drawn in its entirety at each refresh. The Adjust Display Contrast object is used to allow the operator to adjust the Panel Display Contrast. The default Display setting often works in most applications, however lighting may vary based on the location of each application. In these cases the operator can use this object to make adjustments. The current display setting value will appear on the top of the button and will change as the arrow keys are pressed. This button can be modified to various sizes. The Analog Meter object is used to display the current value of a Tag Name. The Function object is used to assign the panels function key buttons to a particular action as well as assigning the control of the LED On/Off status. When a button has been assigned as a shift button, the then F1 through F7 will become F8 through F14. The Function Object buttons will activate when the hardware button is pressed or when the object is pressed on the screen. The object size is restricted so that the keys will line up with the hardware function keys on the panel. The Bar Meter object is used to monitor up to two assigned Tag Names continuously. This object has various appearances depending upon the relative value of the tags. The Bar Meter can be used to create digital versions of level, current, and flow meters to name a few samples, or gauges that measure speed and other measurable data. Book 1 (14.2) www.automationdirect.com/C-more-micro C-more Micro Panels eCK-77 Do-More PLCs Overview Do-More T1H PLC DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL205 DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 Universal Field I/O Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions Prices as of April 15, 2015. Check Web site for most current prices. C-more Micro Programming Connections C-more STN Micro Programming Connection Using the C-more Micro Programming Software for project development, STN C-more Micro panels can be connected to a PC (personal USB to RS-232 Programming Cable computer) by using EA-MG-PGM-CBL, the USB-to-RS-232 cable assembly. •C onnect the USB programming cable (included) from a USB port type A on the PC to the USB Assembly type B port on the converter (included). Next connect the serial programming cable from the converter’s RJ12 port to the panel’s RJ12 serial port. The panel receives power from the USB port of the PC that it is connected to through the USB to RS-232 converter assembly. USB Connectivity USB Cable PC to Panel Programming Cable Assembly (Includes serial & USB cables) p/n EA-MG-PGM-CBL Serial Cable USB to RS232 Converter Part No. EA-MG-PGM-CBL C-more 3” Micro-Graphic Panel User PC NOTE: The TFT panels EA1-T4CL, EA1-T6CL, EA3-T6CL, EA3-T8CL and EA3-T10CL do NOT use the EA-MG-PGM-CBL assembly. The TFT panels use a standard USB A-to-B type cable such as USB-CBL-AB6. See below. $43.00 USB to RS-232 Converter Specifications Part Number Hardware EA-MG-PGM-CBL USB Interface USB Specification Rev. 1.1 Connector: USB Type B jack to accept USB Type B cable plug RS-232 (EIA-232-E) Connector: RJ12 phone jack 6p to accept RJ12 cable plug 115.2 kbps Maximum Serial Interface Baud Rate Input Voltage Power Consumption Accessory Cables (included) USB Cable Serial Cable Physical 5 VDC (Supplied thru serial interface cable.) 50 mA (Does not include power to panel and/or bezel.) USB Type A plug to PC on one end, USB Type B plug to converter on other end, 0.30 m [1 foot] length (* Note) RJ12 phone plug connectors on both ends, 2.0 m [6.56 feet] length (* Note) 2.559” (W) x 1.417” (H) x 0.886” (D) [65.0 mm x 36.0 mm x 22.5 mm] 1.06 oz. [30 g] Dimensions Weight Environmental See Micro panel specifications at the beginning of this catalog section. * Note: Maximum cable length for either the USB or serial cable should not exceed 2.0 m [6.56 feet] in length. C-more TFT Micro Programming Connection The C-more TFT Micro panels EA1-T4CL, EA1-T6CL, EA3-T6CL, EA3-T8CL and EA3-T10CL include an integral USB to serial converter. It is programmed via any USB Type A to Type B cable. When properly installed on your PC, the device driver will be assigned a communication port number and appear in Windows Device Manager as a serial com port. USB cable options for programming EA1-T4CL, EA1-T6CL, EA3-T6CL, EA3-T8CL and EA3-T10CL Part Number Description Price USB-CBL-AB3 Standard 3-ft. (0.9 m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.) $7.50 USB-CBL-AB6 Standard 6-ft. (1.8 m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.) $9.50 USB-CBL-AB10 Standard 10-ft (3 meter) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.) $18.00 USB-CBL-AB15 Standard 15-ft. (4.6 m) USB 2.0 cable, A-type connector to B-type connector, used to connect personal computer to any C-more touch panel for setup and programming. (Note: Touch panels require a 24 VDC power source for configuration and operation.) $22.50 Book 1 (14.2) eCK-78 C-more Micro Panels 1-800-633-0405
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement