TOUCH PANEL RUNTIME ERRORS APPENDIX B In This Appendix... Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B–2 Runtime Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B–3 Appendix B: Touch Panel Runtime Errors 1 B 3 4 5 6 7 8 9 10 11 12 13 14 A B C D Introduction B–2 The C-more touch panels have diagnostics built-in to the operating system that monitor various runtime functions that will display an error message on the panel’s display indicating that a particular error has occurred and what the error represents. The Error Message(s) is displayed in the upper left area of the display screen. The Runtime Errors are also logged into the panel’s Error log under the Information tab in the panel’s System Setup Screens. The Error Log Code, such as RTE-031, is how the error is identified in the error log. See Chapter 5: System Setup Screens for additional details. The tables that follow show the possible Runtime Errors and include the error message, log error code, tag error code value, cause, etc. The user can include in their touch panel project the use of this diagnostic information by using the system tag name SYS ERR ERRORCODE to control displayed screens, operator messages, etc., and also communicate error information to the PLC or controlling device. If a runtime error occurs, the SYS ERR ERRORCODE system tag will contain the numeric value shown under the Tag Code Error Value. For example, if a Low Battery runtime error is indicated, then the screen display will show Low Battery and the SYS ERR ERRORCODE system tag will contain the value 2031. The value of the last runtime error detected will remain in the SYS ERR ERRORCODE. If you have difficulty determining the cause of the error, refer to Chapter 8: Troubleshooting for additional help or contact our technical support group at 770-844-4200 Error Message Low Battery Stride™ Ethernet Switch 10/100 Base-T H0-ECOM/H0-ECOM100 Ethernet Module 1 C-more Touch Panel Ethernet Port (Bottom View) DL06 PLC Ethernet CAT5 Cable - Straight-thru ® EA-USER-M Hardware User Manual, 2nd Ed. Rev. D, 10/09 Appendix B: Touch Panel Runtime Errors Runtime Errors If there is more than one Runtime Error, then the Error Message displayed at the top of the panel’s screen will display for 3 seconds, then be off for 2 seconds. The next Error Message will display for the same time increments, continue through any other active runtime error messages, and then start over. When only one Runtime Error is active, then that message will continuously be displayed until it is no longer active. No. Error Log Code Error Message Located at upper left of screen Error Message Tag Tag Error Code Value System Screen Info > Error Cause Log Error 1 Failed. SYS ERR RTE-001 Log Not enough Memory Space in %Device% ERRORCODE 2001 MM/DD/YY HH/MM/SS Error Code RTE-001 The size of the destination memory is not large enough to store the data. 2 Failed. RTE-002 Log %Device% cannot be found SYS ERR ERRORCODE 2002 MM/DD/YY HH/MM/SS Error Code RTE-002 No device available or the device is defective. 3 Failed. RTE-003 Log Can not write file - %file% SYS ERR ERRORCODE 2003 MM/DD/YY HH/MM/SS Error Code RTE-003 Logging the data has failed due to a problem such as the memory write protect is enabled. 4 RTE-004 Log cache memory is full SYS ERR ERRORCODE 2004 MM/DD/YY HH/MM/SS Error Code RTE-004 The data log buffer in the SRAM memory is full. 1 Failed. SYS ERR RTE-011 Capture Not enough Memory Space in %Device% ERRORCODE 2011 MM/DD/YY HH/MM/SS Error Code RTE-011 The size of the destination memory is not large enough to store the data. 2 Failed. RTE-012 Capture %Device% cannot be found SYS ERR ERRORCODE 2012 MM/DD/YY HH/MM/SS Error Code RTE-012 No device available or the device is defective. 3 Failed. RTE-013 Capture Can not write file - %file% SYS ERR ERRORCODE 2013 MM/DD/YY HH/MM/SS Error Code RTE-013 Logging the data has failed due to a problem such as the memory write protect is enabled. Screen Capture Table continued on next page. ® EA-USER-M Hardware User Manual, 2nd Ed. Rev. D, 10/09 1 B 3 4 5 6 7 8 9 10 11 12 13 14 A B C D B–3 Appendix B: Touch Panel Runtime Errors 1 B 3 4 5 6 7 8 9 10 11 12 13 14 A B C D Runtime Errors (cont’d) Error Log Code No. Error Message Located at upper left of screen Error Message Tag Tag Error Code Value System Screen Info > Error Cause Handshake A communications timeout occurred when either a Recipe or Numeric Entry Object, in which Notification and Handshake signals are used, failed to complete the responses. RTE-021 Handshake Timeout Error SYS ERR ERRORCODE 2021 MM/DD/YY HH/MM/SS Error Code RTE-021 RTE-031 Low Battery SYS ERR ERRORCODE 2031 MM/DD/YY HH/MM/SS Error Code RTE-031 The panel’s backup battery voltage level has fallen below 1.8 VDC and should be replaced. 1 RTE-041 E-mail Connection Error %Address% SYS ERR ERRORCODE 2041 An incorrect SMTP address has been entered into the Touch Panel Network dialog screen. 2 RTE-042 Send E-mail Error %Address% SYS ERR ERRORCODE 2042 MM/DD/YY HH/MM/SS Error Code RTE-041 MM/DD/YY HH/MM/SS Error Code RTE-042 1 Battery 1 e-mail An incorrect email address has been entered into the Address Book. Send FTP 1 Connection Error RTE-051 FTP %Address%&%ID% SYS ERR ERRORCODE 2051 MM/DD/YY HH/MM/SS Error Code RTE-051 2 FTP Error RTE-052 Send %Address%&%ID% SYS ERR ERRORCODE 2052 MM/DD/YY HH/MM/SS Error Code RTE-052 An incorrect FTP Service has been assigned into the Touch Panel Network dialog screen. Permission to write to the FTP folder has not been authorized. The FTP site may require a user ID and password. RTE-081 Sound Failed. Not enough Memory SYS ERR ERRORCODE 2081 MM/DD/YY HH/MM/SS Error Code RTE-081 The sound file failed to play due to insufficient memory. Address Conflict - Corrct IP Address RTE-091 IP and Power Cycle SYS ERR ERRORCODE 2091 MM/DD/YY HH/MM/SS Error Code RTE-091 Conflict of IP Address Sound 1 Confiict 1 B–4 ® EA-USER-M Hardware User Manual, 2nd Ed. Rev. D, 10/09 Appendix B: Touch Panel Runtime Errors Runtime Errors (cont’d) No. Error Log Code Error Error Message Message Located at upper left of screen Tag Tag Error Code Value System Screen Info > Error Cause Multiple Recipe MM/DD/YY HH/MM/SS Error Code RTE-101 MM/DD/YY HH/MM/SS Error Code RTE-102 MM/DD/YY HH/MM/SS Error Code RTE-103 MM/DD/YY HH/MM/SS Error Code RTE-104 MM/DD/YY HH/MM/SS Error Code RTE-105 MM/DD/YY HH/MM/SS Error Code RTE-106 MM/DD/YY HH/MM/SS Error Code RTE-107 MM/DD/YY HH/MM/SS Error Code RTE-108 MM/DD/YY HH/MM/SS Error Code RTE-109 1 RTE-101 Record doesn’t exist SYS ERR ERRORCODE 2101 The recipe file or data doesn’t exist. 2 RTE-102 File cannot open SYS ERR ERRORCODE 2102 3 RTE-103 E-mail Connection Error %Address% SYS ERR ERRORCODE 2103 4 RTE-104 Send E-mail Error %Address% SYS ERR ERRORCODE 2104 5 RTE-105 Recipe - Index (%Row%) error SYS ERR ERRORCODE 2105 6 RTE-106 Not enough buffer memory SYS ERR ERRORCODE 2106 7 RTE-107 File cannot write SYS ERR ERRORCODE 2107 8 RTE-108 Wrong file format SYS ERR ERRORCODE 2108 9 enough Memory Space in RTE-109 Not %Device% SYS ERR ERRORCODE 2109 RTE-121 Action Overflows SYS ERR ERRORCODE 2121 MM/DD/YY HH/MM/SS Error Code RTE-121 The number of actions executed in the event exceeded the maximum number. SYS ERR ERRORCODE 2500 MM/DD/YY HH/MM/SS Error Code RTE-500 Memory in Panel has been Corrupted by Power Loss, etc. The recipe file cannot be opened. Abnormality is found in the numberic character data of the recipe file. Abnormality is found in the Tag data of the recipe file. Recipe was operated by the record number outside the range. Memory allocation error There was an error trying to write the recipe file. The recipe file format is incorrect. Insufficient storage space on media. Action 1 SRAM Error 1 RTE-500 SRAM Check Sum Error ® EA-USER-M Hardware User Manual, 2nd Ed. Rev. D, 10/09 1 B 3 4 5 6 7 8 9 10 11 12 13 14 A B C D B–5
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement