Amphenol Cable Glands and Cord Grips

Amphenol Cable Glands and Cord Grips

Amphenol

®

Cable Glands and

Cord Grips

12-055

Amphenol

Table of Contents

Introduction

Amphenol

®

Cable Glands

ATEX Approved Glands Featuring Elastometric Seals

EX-20

EX-25

EE-30

EX-35

EX-40

EX-45

EE-RG

ATEX Approved Glands Featuring Elastometric Seals for Flat Cable

EX-50

EX-55

ATEX Approved Barrier Glands

EX-60

EX-65

EX-70

EX-75 Stopper Box

Industrial Glands

CGA

CGSS

CGDS

CGU

Accessories

AR Adaptors & Reducers

Nylon Adaptors & Reducers

Insulated Adaptors

Mushroom Head Stopping Plugs

Nylon Mushroom Head Stopping Plugs

Type A & Type B Stopping Plugs

Breather Drain

Locknuts, Earth Tags, etc.

Entry Thread Reference Tables

Ingress Protection, Gland Weight Data

Amphenol ® /Pyle ® Cord Grips

Cord Grip Specifications

DB/DBM Group

DBZ Group

DBL/DBZL Group

DBA Group

DBF Group, Flared Nipples

DBZP Series

Grommets

Accessories

Addtional Amphenol ® Industrial Products

Amphenol Sales Offices and Distributors Listing

Page Number

1

2-3

4-5

6-7

8-9

10-11

12-13

14-15

16-17

18-19

20-21

22-23

24-25

26-27

28-29

30-31

32-33

34-35

36-37

For further information on your individual application requirements, contact:

Amphenol Corporation

Amphenol Industrial Operations

40-60 Delaware Avenue

Sidney, New York 13838-1395

Phone: 607-563-5011 Fax: 607-563-5351

View and download or print Amphenol catalogs on-line at: www.amphenol-industrial.com

Amphenol operates quality systems that are certified to ISO 9001:2000 by third party registrars.

For product specific questions regarding RoHS compliance, consult Amphenol Industrial Operations, or call the

RoHS Product Compliance and Technical Support line: 1-866-315-8559

52

53

54

55

56-57

58-59

60-61

62-63

64-65

66-67

68-69

70-71

72-73

74-75

76

38-39

40-41

42-43

44-45

46-47

48-49

50-51

Amphenol Industrial Operations

Amphenol

®

Cable Glands and Cord Grips

Amphenol Industrial offers more choices, more solutions, and more options than any other interconnect manufacturer in the world. In addition to the broadest range of connector solutions in the market, we also offer an extensive line of Explosion Proof and General Duty Cable Glands. We also carry a complete line of liquid tight strainrelief products in our Cord Grip line of performance cable seals. Our combination of Glands and Cord Grips makes

Amphenol Industrial the one stop supplier for all your connector and cable sealing solutions.

Cable Glands

Amphenol Industrial Operations, the worldwide leader of explosion proof and hazardous environment interconnects, introduces our broad range of explosion proof and industrial cable glands. The new

Cable Gland product line is designed toperform in the most demanding environments. Amphenol’s complete line of EX Zone 1 and 2 rated cable glands offers our customers great flexibility. In addition, we have a complete line of general duty industrial application cable glands suitable for armored and unarmored cable.

• SIRA/ATEX certified to Exd/Exe (Class I, Div. I)

• CSA Approved

• IP66/68; Deluge; NEMA rated products

• Temperature Ranges from -40°F to +180°F

• Brass and Stainless Steel available.

Amphenol Cable Glands are RoHS

Compliant.

Cord Grips

Whether you need a straight, 45°, or 90° strain relief,

Amphenol’s family of cord Grips has you covered.

Strong, lightweight aluminum components provide a long lasting, reliable liquid tight solution. Amphenol

Industrial Cord Grips offer a complete line of strain relief options that include gland nuts, mechanical clamps and basketweave cable grips. UL and CSA listed, our Cord Grips have been put to the test for over 40 years.

• Tapered rubber grommets and seal

• Machined Components

• Male and female threads available

• Tapered conduit threads

Amphenol Cord Grips are available with RoHS Compliant options.

Please contact Amphenol Industrial Operations for information.

1

Amphenol Cable Glands and Cord Grips

Amphenol Explosion Proof and Industrial Cable Glands

This section will provide you with information on Amphenol’s complete family of cable glands, and will assist you in determining which of our glands will satisfy your specific need. If you have further questions, please contact our factory or one of the Amphenol Industrial distributors listed in the back of this catalog.

Amphenol Industrial Operations, the recognized leader in explosion proof and hazardous environment interconnects, offers a complete line of Industrial and Explosion Proof Glands. Whether part of an integrated connector solution, or as part of a bulkhead feed through, Amphenol has the solution you are looking for. Our product range includes general duty industrial cable glands meant to seal on unarmored cable, right up to our ATEX approved EX glands capable of protecting the most rugged cable in your zone rated applications.

Our EX Approved Glands also provide a complete zone rated interconnect solution when used in conjunction with our ATEX approved Star-Line EX explosion proof connector series. For additional information on the Star-Line EX product, consult Amphenol catalog 12-054.

Features & Benefits

ATEX and CSA Certified:

Approved to perform in the most hazardous environments.

Variety of Styles:

Cable glands available to accommodate any cable type.

IP Ratings Included:

Watertight seals allow for both indoor and outdoor applications.

Machined Components

made from brass and stainless steel.

Complete Line of Accessories:

Including locknuts, washers, and earth tags.

Entry Thread Flexibility:

Both metric and NPT threads available on most styles.

Applications

• Oil and Gas Exploration Equipment

• Machine and Heavy Electronics

• Pharmaceutical Manufacturing Facilities

• Production Platforms

• Chemical and Paint Manufacturing Facilities

• Robotics and Welding Equipment

• Process Control Equipment

• Motors and Generators

2

Amphenol Cable Glands

Cable Gland Selection Guide

This table is designed to be a quick reference to the cable glands found in this publication.

Gland Type Outer Seal Inner Seal Lead Option Armor Clamp Certification

ATEX/CSA Approved Glands with Elastomeric Seals

EX-20

✓ ✓ ✓ ✓

Exd/Exe

EX-25

EE-30

EX-35

Exd/Exe

(Not CSA)

Exe

(Not CSA)

Exd/Exe

IP Rating

Deluge, IP66, 68

NEMA, 4X

IP66, IP67

IP66

EX-40

EX-45

x2

Exd/Exe

Exd/Exe

EE-RG

✓ ✕ ✕ ✕

Exe

ATEX/CSA Approved Glands with Elastomeric Seals for Flat Cable

EX-50 Flat Cable Flat Cable

Braid Exd/Exe

IP66

IP68

NEMA 4X

IP66

IP68

NEMA 4X

IP66

IP68

NEMA 4X

IP66

IP68

IP66

EX-55 Flat Cable

✕ ✕ ✕

Exd/Exe IP68

Page Number

10

12

14

16

18

20

4

6

8

ATEX Approved Compound Filled Barrier Glands

EX-60

EX-65

EX-70

Compound Compound

Compound

Compound

Exd

Exd

Exd

EX-75

(stopper box)

Compound

Non Hazardous Industrial Glands

CGA

CGSB

CGDS

CGU

Exd

Industrial (BS6121)

www.amphenol-industrial.com

Industrial

Industrial

Industrial

Deluge, IP66, IP68

NEMA, 4X

Deluge, IP66, IP68

NEMA, 4X

Deluge, IP66, IP68

NEMA, 4X

Deluge, IP66, IP68

NEMA, 4X

IP30

IP66

IP67

IP66, IP66

22

24

26

28

30

32

34

36

3

ATEX/CSA Approved Glands with Elastomeric Seals

EX-20 type glands provide a seal on the inner sheath, a seal on the outer sheath, an entry thread seal and a universal armor clamp for armored cable. The armor clamp provides an electrical bond between the cable armor and the gland. EX-20 glands can also be used to terminate unarmored or lead sheathed cables. EX-20 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection; IP66, 68 to 25 meters and is deluge resistant. An integral ‘O’ ring entry thread seal is fitted to metric versions as standard.

EXAMPLE PART NUMBER

EX-20 [W] [X] [Y] [R] [YY] [ZZ]

W

Gland material (B = Brass / S = Stainless Steel)

X -

Seal Material (1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

R

Reduced bore option

YY

Gland size (Cable Range)

ZZ

Entry thread

Sample: EX-20-B-1-0-R-20-M20

A

D

B

DESIGN STANDARD

EN50014:1998, EN50018:2000, EN50019:2000 & EN 50281-1-1:1998

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd IIC/Exe II 4X, Class 1, Zone 1

CERTIFICATE

Sira 05ATEX1120X - Ex Notified Body No. 0518

Pending

GLAND MARKING

CENELEC and ATEX

Example

:

Amphenol 13838 USA EX-20-B-1-0-R-20-M20 XX Sira 05ATEX1120X II 2GD EExdIIC / EExe II (XX = Year Code)

APPLICATION

EExd Equipment

EX-20 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume Which Zone Use Type EX-20 Gland

IIC, IIB, IIA

IIB, IIA

IIB, IIA

N O

YES

YES

Any

Any

2 liters or less

Zone 1 or 2

Zone 2

Zone 1

YES

YES

YES

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

C

INGRESS PROTECTION

IP66 and IP68 @ 25 meters, Enclosure Type 4X

Meets the requirements of DTS01 1991

OPERATING TEMPERATURES

Standard Seals -20°C to +85°C

Extended Seals - 60°C to +180°C (Silicone seals)

MATERIALS

Brass CZ121 (EX-20-B)

316 Stainless Steel (EX-20-S)

Inner and outer sheath material: Standard (EX-20-W-1) Neoprene, black. Option (EX-20-W-3) Silicone, white.

Reduced bore outer sheath seal (R) Silicone, red (EX-20-W-X-Y-R)

Entry thread seal: Nitrile is supplied with neoprene seal version. Silicone is supplied with silicone seal version

4

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread

(BSP Taper, BSP Parallel)

SEALS

Extended operating temperature -60°C to +180°C, halogen free versions:

Brass (EX-20-B-3); 316 Stainless Steel (EX-20-S-3)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless

Nickel (4)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC)

Gland and accessory kits:

K1- includes gland, locknut, earthtag, nylon IP washer and PVC shroud

Gland

Size

Entry Threads Entry

Thread

Length

Max Max

Across Protrusion

Corners Length

Cable Inner

Gland Seal Range

Cable Outer Sheath [D]

Sheath [C] Standard Reduced (R)

Armor

Acceptance

Range

Shroud

Size

Min Max Min Max Min Max

Metric NPT/BSP [B] [A]

63

75s

75

80

80H

85

90

90H

100

16

20s

50s

50

63s

20

25

32

40

M63

M75

M75

M80 x 2

M80 x 2

M85 x 2

M90 x 2

M90 x 2

M100 x 2

M20

M20

M20

M25

M32

M40

M50

M50

M63

25

25

25

19

19

19

25

25

25

16

16

16

16

19

16

16

16

16

N7

N7 or N8

N8

N8 or N9

N8 or N9

N8 or N9

N9 or N10

N9 or N10

N9 or N10

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

28.0

28.0

33.0

41.4

50.6

60.5

71.5

71.5

88.0

78.0

78.0

78.0

90.0

105.0

113.0

125.0

125.0

125.0

3.4

7.2

9.4

13.5

19.5

23

28.1

33.1

39.2

8.4

11.7

14.0

20.0

26.3

32.2

38.2

44.1

50.1

88.0

99.0

99.0

115.2

115.2

115.2

125.7

125.0

131.0

131.0

170.0

170.0

170.0

170.0

46.7

52.1

58.0

62.2

62.2

69.0

74.0

56.0

62.0

68.0

72.0

72.0

78.0

84.0

125.7

125.7

170.0

170.0

74.0

82.0

84.0

90.0

All Dimensions are in millimeters

92.0

92.0

58.4

64.8

71.1

77.0

79.6

79.6

88.0

9.0

11.5

15.5

20.3

26.7

33.0

39.4

45.7

52.1

0.30 - 2.50

0.30 - 2.50

0.30 - 2.50

0.45 - 3.15

0.45 - 3.15

0.45 - 3.15

0.45 - 3.15

0.45 - 3.15

0.45 - 3.15

0.15 - 1.25

0.15 - 1.25

0.15 - 1.25

0.15 - 1.60

0.15 - 2.00

0.20 - 2.00

0.30 - 2.50

0.30 - 2.50

0.30 - 2.50

61.2

68.0

73.4

-

-

85.4

-

-

97.4

10.3

12.5

17.6

23.9

30.5

36.2

42.4

48.5

54.8

53.8

60.2

66.5

-

-

75.0

-

-

87.4

6.7

9.4

12.0

16.8

23.2

28.6

34.8

41.1

47.5

65.8

72.2

78.0

84.0

90.0

90.0

96.0

102.0

102.0

13.5

16.0

21.1

27.4

34.0

40.6

46.7

53.2

59.5

NOTES:

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• Where EX-20 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

• When used to terminate unarmored cable, the gland is suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting.

EL80

EL90

EL90

L104

L104

L104

L114

L114

L114

L24

L24

EL30

EL38

EL46

EL55

EL65

EL65

EL80

5

ATEX/CSA Approved Glands with Elastomeric Seals

EX-25

EX-25 type glands provide a seal on the inner sheath, a seal on the outer sheath and an armor specific clamp for armored cable. The armor clamp provides an electrical bond between the cable armor and the gland. EX-25 type connectors can be used to terminate lead sheath cables. EX-25 type glands maintain Flameproof Exd and

Increased Safety Exe methods of explosion protection and IP66, IP67.

EXAMPLE PART NUMBER

EX-25* [W] [X] [Y] [R] [YY] [ZZ]

*

Armor Types (W = SWA / X = SWB / Z = STA)

W

Gland material (B = Brass / S = Stainless Steel)

X -

Seal Material (1 = Neoprene / 3 = Silicone / 4 = No Seal)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

R

Reduced bore option

YY

Gland size (Cable Range)

ZZ

Entry Thread

Sample: EX-25-W-B-1-0-R-20-M20

DESIGN STANDARD

EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998

A D

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CERTIFICATE

SIRA 05ATEX1122X - Ex Notified Body No. 0518

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-25W-B-1-0-R-20-M20 XX SIRA 05ATEX1122X II 2GD IP67 EExdIIC / EExe II (XX = Year Code)

B

C

APPLICATION

EExd Equipment

EX-25 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume

IIC, IIB, IIA N O Any

IIB, IIA

IIB, IIA

YES

YES

Any

2 litres or less

Which Zone

Zone 1 or 2

Zone 2

Zone 1

Use Type EX-25 Gland

YES

YES

YES

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP66 and IP67

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +180°C

VARIATIONS

Omission of outer seal:

Brass (EX-25*-B-4); 316 Stainless Steel (EX-25-*-S-4)

MATERIALS

Brass CZ121 (EX-25-*-B)

316 Stainless Steel (EX-25-*-S)

6

SEALS

Extended operating temperature -60°C to +180°C, halogen free versions:

Brass (EX-25-B-3); 316 Stainless Steel (EX-25-S-3)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread

(BSP Taper, BSP Parallel)

CLAMPS

SWA steel wire armor (EX-25-W)

SWB woven steel wire armor (EX-25-X)

STA steel tape armor (EX-25-Z)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH)

Gland and accessory kits:

K2 - includes gland, locknut, earthtag, fibre IP washer and PVC shroud

K3 - includes gland, locknut, earthtag, nylon IP washer and PCP shroud

K4 - includes brass gland, brass locknut, brass earthtag, IP washer and zero halogen shroud

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless

Nickel (4)

Gland

Size

Entry Threads Entry Max Max

Thread Across Protrusion

Length Corners

[B] [A]

Length

Cable Inner

Sheath [C]

Min Max

Gland Seal Range

Cable Outer Sheath [D]

Standard Reduced (R)

Min Max Min Max

Armour Acceptance

Range

Shroud

Size

Metric NPT/BSP

W XZ

40

50s

50

63s

63

75s

16

20s

20

25

32

75

80

80H

85

90

90H

100

M40

M50

M50

M63

M63

M75

M20

M20

M20

M25

M32

M75

M80 x 2

M80 x 2

M85 x 2

M90 x 2

M90 x 2

M100 x 2

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

N7

N7 or N8

N8

N8 or N9

N8 or N9

N8 or N9

N9 or N10

N9 or N10

N9 or N10

60.5

71.5

71.5

88.0

88.0

99.0

26.5

26.5

33.0

41.4

50.6

99.0

115.2

115.2

115.2

125.7

125.7

125.7

16

16

16

19

19

19

16

16

16

16

16

25

25

25

19

25

25

25

72.0

73.0

73.0

76.0

76.0

82.0

58.0

58.0

58.0

58.0

65.0

25.0

31.5

36.5

42.5

49.5

54.5

4.0

8.0

6.7

*

13.0

19.0

32.2

38.2

44.1

50.1

56.0

62.0

8.4

11.7

14.0

20.0

26.3

82.0

110.0

110.0

110.0

110.0

110.0

110.0

60.5

62.2

62.2

69.0

74.0

74.0

82.0

68.0

72.0

72.0

78.0

84.0

84.0

90.0

All Dimensions are in Millimeters

71.1

77.0

79.6

79.6

88.0

92.0

92.0

33.0

39.4

45.7

52.1

58.4

64.8

8.4

11.5

15.5

20.3

26.7

40.6

46.7

53.2

59.5

65.8

72.2

13.5

16.0

21.1

27.4

34.0

78.0

84.0

90.0

90.0

66.5

73.4

-

-

75.0

85.4

96.0

102.0

-

-

-

-

102.0

87.4

97.4

4.9

9.4

10.0

12.5

12.0

17.6

16.8

23.9

23.2

30.5

28.6

36.2

34.8

42.4

41.1

48.5

47.5

54.8

53.8

61.2

60.2

68.0

0.90

0.90-1.25

0.90-1.25

1.25-1.60

1.60-2.00

1.60-2.00

2.00-2.50

2.00-2.50

2.50

2.50

2.50

2.50

3.15

3.15

3.15

3.15

3.15

3.15

NOTES:

* EX-25 gland size 20, the silicone inner seal only seals to a minimum of 11.0mm and NOT 6.7mm.

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• "W" refers to the wire diameter in a steel wire armored cable.

• "XZ" refers to the wire diameter in a woven steel wire armored cable or the tape thickness in a steel tape armored cable.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• Where EX-25 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

7

0.15-0.35

0.15-0.35

0.15-0.50

0.15-0.50

0.15-0.55

0.20-0.60

0.20-0.60

0.30-0.80

0.30-0.80

0.30-0.80

0.30-1.00

0.30-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

L55

L65

L65

L80

L80

L90

L24

L24

L30

L38

L46

L90

L104

L104

L104

L114

L114

L114

ATEX/CSA Approved Glands with Elastomeric Seals

EE-30

EE-30 type glands provide a seal on the outer sheath and an armor specific clamp for armored cable. The armor clamp provides an electrical bond between the cable armor and the gland. EE-30 type glands maintain Increased

Safety Exe methods of explosion protection and IP66.

EXAMPLE PART NUMBER

EE-30* [W] [X] [Y] [R] [YY] [ZZ]

*

Armor Type (W = SWA / X = SWB / Z = STA)

W

Gland material (B = Brass / S = Stainless Steel)

X -

Seal Material (1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

R

Reduced bore option

YY

Gland size (Cablle Range)

ZZ

Entry thread

Sample: EE-30W-B-1-0-R-20-M20

DESIGN STANDARD

EN 50014:1998, EN 50019:2000 and EN 50281-1-1:1998

CERTIFICATION

ATEX II 2 GD, E Exe II

A

D

CERTIFICATE

SIRA 05ATEX1122X - Ex Notified Body No. 0518

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EE-30W-B-1-0-R-20-M20 XX SIRA 05ATEX1122X II 2GD IP66 EExe II ( XX = Year Code)

APPLICATION

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

B

INGRESS PROTECTION

IP66

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +180°C

MATERIALS

Brass CZ121 (EE-30*-B)

316 Stainless Steel (EE-30*-S)

SEALS

Extended operating temperature -60°C to +180°C, halogen free versions:

Brass (EE-30*-B-3); 316 Stainless Steel (EE-30*-S-3)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread

(BSP Taper, BSP Parallel)

CLAMPS

SWA steel wire armor (EE-30-W)

SWB woven steel wire armor (EE-30-X)

STA steel tape armor (EE-30-Z)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless

Nickel (4)

C

8

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH)

Gland and accessory kits:

K1 - includes gland, locknut, earthtag, nylon IP washer and PVC shroud

K4 - includes brass gland, brass locknut, brass earthtag, IP washer and zero halogen shroud

Gland

Size

Entry Threads Entry Max Max

Thread Across Protrusion

Length Corners Length

[B] [A]

Cable Inner

Sheath [C]

Min Max

Gland Seal Range

Cable Outer Sheath [D]

Standard Reduced (R)

Min Max Min Max

Armour Acceptance

Range

Shroud

Size

W XZ

Metric NPT/BSP

50

63s

63

75s

75

80

80H

85

90

90H

100

16

20s

20

25

32

40

50s

M50

M63

M63

M75

M75

M80 x 2

M20

M20

M20

M25

M32

M40

M50

M80 x 2

M85 x 2

M90 x 2

M90 x 2

M100 x 2

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

N7

N7 or N8

N8

N8 or N9

N8 or N9

N8 or N9

N9 or N10

N9 or N10

N9 or N10

71.5

88.0

88.0

99.0

99.0

115.2

115.2

115.2

125.7

125.7

125.7

26.5

26.5

33.0

41.4

50.6

60.5

71.5

15

15

15

15

15

20

20

20

20

20

20

10

15

15

10

10

10

10

-

-

-

-

-

-

-

-

-

-

-

-

-

67.0

69.0

69.0

77.0

77.0

104.0

54.0

54.0

54.0

54.0

60.0

67.0

67.0

11.7

11.7

14.0

20.0

26.3

32.2

38.2

44.1

50.1

56.0

62.0

68.0

72.0

9.0

11.5

15.5

20.3

26.7

33.0

39.4

45.7

52.1

58.4

64.8

71.1

77.0

13.5

16.0

21.0

27.4

34.0

40.6

46.7

53.2

59.5

65.8

72.2

78.0

84.0

104.0

104.0

104.0

104.0

-

-

-

72.0

78.0

84.0

84.0

79.6

79.6

88.0

92.0

90.0

90.0

96.0

102.0

-

-

-

75.0

85.4

-

-

104.0

90.0

92.0

All Dimensions are in Millimeters

102.0

87.4

97.4

6.7

9.4

10.3

12.5

12.0

17.6

16.8

23.9

23.2

30.5

28.6

36.2

34.8

42.4

41.1

48.5

47.5

54.8

53.8

61.2

60.2

68.0

66.5

73.4

-

0.90-1.25

0.90-1.25

0.90-1.25

1.25-1.60

1.60-2.00

1.60-2.00

2.00-2.50

2.00-2.50

2.50

2.50

2.50

2.50

3.15

3.15

3.15

3.15

3.15

3.15

NOTES:

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• "W" refers to the wire diameter in a steel wire armored cable.

• "XZ" refers to the wire diameter in a woven steel wire armored cable or the tape thickness in a steel tape armored cable.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• Where EX-30 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

0.15-0.35

0.15-0.35

0.15-0.50

0.15-0.50

0.15-0.55

0.20-0.60

0.20-0.60

0.30-0.80

0.30-0.80

0.30-0.80

0.30-1.00

0.30-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

L65

L80

L80

L90

L90

L104

L104

L104

L114

L114

L114

L24

L24

L30

L38

L46

L55

L65

9

ATEX/CSA Approved Glands with Elastomeric Seals

EX-35

EX-35 type glands provide a single pull resistant seal on the outer sheath of unarmoured cable. EX-35 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to

25 meters. Integral O-Ring entry thread seal, as illustrated, is provided as standard on metric versions.

EXAMPLE PART NUMBER

EX-35 [W] [X] [Y] [YY] [ZZ]

W

Gland material (B = Brass / S = Stainless Steel)

X -

Seal Material (1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY

Gland size (Cable Range)

ZZ

Entry thread

Sample: EX-35-B-1-0-20-M20

DESIGN STANDARD

EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998

CERTIFICATION.

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd IIC/Exe II 4X, Class 1, Zone 1

A D

CERTIFICATE

SIRA 05ATEX1123X - Ex Notified Body No. 0518

Pending

B

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-35-B-1-0-20-M20 XX SIRA 05ATEX1123X II 2GD IP68 EExdIIC / EExe II (XX = Year Code)

APPLICATION

EExd Equipment

EX-35 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-35 Gland

IIC, IIB, IIA N O 2 liters or less Zone 1 or 2 YES

IIB, IIA

IIB, IIA

YES

YES

Any

2 liters or less

Zone 2

Zone 1

YES

YES

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP66 and IP68 @ 25 meters, Enclosure Type 4X

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +180°C

MATERIALS

Brass CZ121 (EX-35-B)

316 Stainless Steel (EX-35-S)

Outer sheath seal material:

Standard (EX-35-W-1) Neoprene, black. Option (EX-35-W-3) Silicone, white.

Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone outer seal version.

10

THREADS

ISO Metric; NPT; NPS; ISO Pipe

Thread (BSP Taper, BSP Parallel)

SEALS

Extended operating temperature -60°C to +180°C, halogen free versions:

Brass (EX-35-B-3); 316 Stainless Steel (EX-35-S-3)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-SPVC); PCP (EX-SPCP); Low Smoke Zero Halogen (EX-LSH)

Gland and accessory kits:

K2 - includes gland, locknut, fiber IP washer and PVC shroud

K3- includes gland, locknut, nylon IP washer and PCP shroud

PLATING

Nickel (1); Tin (2); Zinc (3);

Electroless Nickel (4)

Gland Size Entry Threads Entry Thread

Length

Max Across

Corners

Max

Protrusion

Length

Gland Seal Rance

Cable Outer/Lead Sheath

Shroud Size

[B] [A] Min Max

16

20s

20

25

32

40

50s

50

63s

63

75s

75

80

85

90

100

Metric

M20

M20

M20

M25

M32

M40

M50

M50

M63

M63

M75

M75

M80 x 2

M85 x 2

M90 x 2

M100 x 2

NPT/BSP

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

N7

N7 or N8

N8

N8 or N9

N8 or N9

N9 or N10

N9 or N10

16

19

19

16

16

16

16

16

16

16

28.0

28.0

33.0

41.4

50.6

60.5

71.5

71.5

88.0

88.0

19

19

25

25

99.0

99.0

115.2

115.2

37.0

37.0

50.0

50.0

25

25

125.7

125.7

50.0

50.0

All Dimensions are in Millimeters

33.0

33.0

33.0

33.0

33.0

37.0

37.0

37.0

37.0

37.0

4.0

7.2

9.6

13.5

19.5

23.0

28.2

33.2

39.3

46.7

52.3

58.1

62.3

69.1

74.1

82.1

8.4

11.7

14.0

20.0

26.3

32.2

38.2

44.1

50.1

56.0

62.0

68.0

72.0

78.0

84.0

90.0

NOTES:

• NPT entry thread reference details on page 53.

• Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• Where EX-35 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

L24

L24

L30

L38

L46

L55

L65

L65

L80

L80

L90

L90

L104

L104

L114

L114

11

ATEX/CSA Approved Glands with Elastomeric Seals

EX-40

EX-40 type glands provide two pull resistant seals on the outer sheath of any cable. EX-40 type glands maintain

Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to 25 meters. An integral O-Ring entry thread seal, as illustrated, is provided as standard on metric versions.

EXAMPLE PART NUMBER

EX-40 [W] [X] [Y] [YY] [ZZ]

W

Gland material (B = Brass / S = Stainless Steel)

X -

Seal Material (1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY

Gland size (Cable Range)

ZZ

Entry thread

Sample: EX-40-B-1-0-20-M20

DESIGN STANDARD

EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998

A

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd IIC/Exe II 4X, Class 1, Zone 1

CERTIFICATE

SIRA 05ATEX1123X - Ex Notified Body No. 0518

Pending

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-40-B-1-0-20-M20 XX SIRA 05ATEX1123X II 2GD IP68 EExdIIC / EExe II (XX = Year Code)

B

APPLICATION

EExd Equipment

EX-40 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-40 Gland

IIC, IIB, IIA

IIB, IIA

IIB, IIA

N O

YES

YES

Any

Any

2 litres or less

Zone 1 or 2

Zone 2

Zone 1

YES

YES

YES

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP66 and IP68 @ 25 meters, Enclosure Type 4X

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +180°C

MATERIALS

Brass CZ121 (EX-40-B)

316 Stainless Steel (EX-40-S)

Outer sheath seal material: Standard (EX-40-W-1) Neoprene, black. Option (EX-40-W-3) Silicone, white

Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone outer seal version.

D

12

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread

(BSP Taper, BSP Parallel)

SEALS

Extended operating temperature -60°C to +180°C, halogen free versions:

Brass (EX-40-B-3); 316 Stainless Steel (EX-40-S-3)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless

Nickel (4)

Gland Size Entry Threads Entry Thread

Length

Max Across

Corners

Max

Protrusion

Length

Gland Seal Rance

Cable Outer/Lead Sheath

Shroud Size

[B] [A] Min Max

16

20s

50s

50

63s

20

25

32

40

63

75s

75

80

85

90

100

Metric

M20

M20

M20

M25

M32

M40

M50

M50

M63

M63

M75

M75

M80 x 2

M85 x 2

M90 x 2

M100 x 2

NPT/BSP

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

N7

N7 or N8

N8

N8 or N9

N8 or N9

N9 or N10

N9 or N10

16

16

16

16

19

16

16

16

16

28.0

28.0

29.7

39.6

45.1

55.9

71.5

71.5

88.0

25

25

25

19

19

19

25

88.0

99.0

99.0

115.2

115.2

125.7

125.7

All Dimensions are in Millimeters

74.0

74.0

74.0

100.0

100.0

100.0

100.0

66.0

66.0

66.0

66.0

66.0

74.0

74.0

74.0

74.0

4.0

7.2

9.6

13.5

19.5

23.0

28.2

33.2

39.3

46.7

52.3

58.1

62.3

69.1

74.1

82.1

L24

L24

L27

L36

L41

L51

L65

L65

L80

L80

L90

L90

L104

L104

L114

L114

8.4

11.7

14.0

20.0

26.3

32.2

38.2

44.1

50.1

56.0

62.0

68.0

72.0

78.0

84.0

90.0

NOTES:

• NPT entry thread reference details on page 53.

• Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• Where EX-35 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

.

13

ATEX/CSA Approved Glands with Elastometric Seals

EX-45

EX-45 type glands provide a seal on the outer sheath of unarmoured cable and a conduit connection thread. EX-

40-M type glands provide a male thread for connection and EX-40-F type glands provide a female thread for connection. EX-45 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to 25 metres. An ‘O’ ring IP entry thread seal is fitted as standard.

EXAMPLE PART NUMBER

EX-45 [A] [W] [X] [Y] [YY] [ZZ]

A -

M = Male Connector / F = Female Connector

W

Gland material (B = Brass / S = Stainless Steel)

X -

Seal Material (1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

Z -

Connection Thread

YY

Gland size (Cable Range)

ZZ

Entry thread

Sample: EX-45-F-B-1-0-M20-20-M20

A

A

B

D

DESIGN STANDARD

EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd IIC/Exe II 4X, Class 1, Zone 1

CERTIFICATE

SIRA 05ATEX1123X - Ex Notified Body No. 0518

Pending

B

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-45-F-B-1-0-M20-20-M20 XX SIRA 05ATEX1123X II 2GD IP68 EExdIIC / EExe II (XX = Year Code)

APPLICATION

EExd Equipment

EX-45 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-45 Gland

IIC, IIB, IIA

IIB, IIA

IIB, IIA

N O

YES

YES

Any

Any

2 litres or less

Zone 1 or 2

Zone 2

Zone 1

YES

YES

YES

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

D

INGRESS PROTECTION

IP66 and IP68 @ 25 meters, Enclosure Type 4X

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +180°C

MATERIALS

Brass CZ121 (EX-45-A-B)

316 Stainless Steel (EX-45-A-S)

Outer sheath seal material: Standard (EX-45-A-W-1) Neoprene, black. Option (EX-45-A-W-3) Silicone, white

Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone outer seal version.

14

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread

(BSP Taper, BSP Parallel); PG

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Gland Size Entry Threads

SEALS

Extended operating temperature -60°C to +180°C, halogen free versions:

Brass (EX-45-A-B-3); 316 Stainless Steel

(EX-45-A-S-3)

Entry Thread

Length

[B]

Max Across

Corners

[A]

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless

Nickel (4)

Gland Seal Rance

Cable Outer Sheath [D]

Min Max

Conduit Connector

Metric NPT/BSP NPT ISO

16

20s

20

25

32

40

50s

50

63s

63

75s

75

M20

M20

M20

M25

M32

M40

M50

M50

M63

M63

M75

M75

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6or N7

N7

N7 or N9

N9

16

16

16

16

16

16

16

16

28.0

28.0

33.0

41.4

50.6

60.5

71.5

71.5

4.0

7.2

19

19

19

19

88.0

88.0

99.0

99.0

All Dimensions are in Millimeters

39.3

46.7

52.3

58.1

9.6

13.5

19.5

23.0

28.2

33.2

8.4

11.7

14.0

20.0

26.3

32.2

38.2

44.1

50.1

56.0

62.0

68.0

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6or N7

N7

N7 or N9

N9

NOTES:

• Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• Where EX-35 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

• Other conduit connection threads eg PG, BSP are available upon request.

M20

M20

M20

M25

M32

M40

M50

M50

M63

M63

M75

M75

15

ATEX/CSA Approved Glands with Elastometric Seals

EE-RG

EE-RG type glands provide a seal on the outer sheath of unarmoured cable. EE-RG type glands maintain

Increased Safety Exe method of explosion protection and IP66, IP68.

EXAMPLE PART NUMBER

EE-RG[X]-[ZZ]

X -

Material (1 = Black Polyamide 6 / 2 = Blue Polyamide 6 / 3 =

Grey Polyamide 6)

ZZ -

Entry Thread

EE-RG1-M20

DESIGN STANDARD

EN50014:1997 and EN50019:2000

CERTIFICATION

ATEX II 2 GD, E Exe II

CERTIFICATE

SIRA 00ATEX 1072 - Ex Notified Body No. 0518

GLAND MARKING

Example:

SIRA 00ATEX1072X EB (Cable Range) II2GD EExeII

For industrial versions the hazardous area information is omitted

APPLICATION

Exe Equipment

Gas Group II, Zones 1 and 2

INGRESS PROTECTION

IP66 without a sealing washer

IP68 with a sealing washer

OPERATING TEMPERATURES

Sizes M25 and below: -20°C to +60°C

Sizes above M25: -10°C to +60°C

MATERIALS

Standard (EX-RG1) Black Polyamide 6

Option (EE-RG2) Blue Polyamide 6

Industrial, Non Ex Versions: Grey Polyamide 6 (EE-RG3)

Note: Polyamide 6 is self extinguishing, flame retardant and halogen free

Outer Seath seal material: Santoprene, black

THREADS

ISO Metric

ACCESSORIES

Locknut - Nylon (EX-NLN); Brass (EX-BLN)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

16

Gland Size Entry

Thread

Length

Max

Across

Corners

Gland Seal Range

Cable Outer Sheath

Metric Min

-

M25

M32

M40

-

M16

-

M20

M50

M63

10

11

12

14

9

10

9

9

16

16

28.6

35.2

45.1

57.2

16.5

20.9

24.2

26.4

64.9

71.5

All Dimensions are in Millimeters

10.0

13.0

18.0

24.0

3.5

5.0

6.0

8.0

29.0

36.0

NOTES:

• Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting

• Gland sizes M25 and above shall not be used for applications where there is a "high" risk of mechanical damage

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

Max

15.0

19.0

25.0

32.0

6.0

8.0

10.0

13.5

38.0

44.0

17

ATEX/CSA Approved Glands with Elastometric Seals for Flat Cable

EX-50

EX-50 type glands provide pull resistant seals on the inner and outer sheath and a braid armor clamp. The armor clamp provides an electrical bond between the cable armor and the gland. EX-50 type glands maintain

Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66.

EXAMPLE PART NUMBER

EX-50 [W] [Y] [YY] [ZZ]

W -

Gland Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

Sample: EX-50-B-3-20S-M20

DESIGN STANDARD

EN 50014:1998, EN 50018:2000, EN 50019:2000 and EN 50281-1-1:1998

A

D

B

C

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CERTIFICATE

SIRA 05ATEX1121X - Ex Notified Body No. 0518

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-50-B-3-20S-M20 XX SIRA 05ATEX1121X II 2GD IP66 EExdIIC / EExe II (XX = Year Code)

APPLICATION

EExd Equipment

EX-50 type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-50 Gland

IIC, IIB, IIA

IIB, IIA

IIB, IIA

N O

YES

YES

2 litres or less

Any

2 litres or less

Zone 1 or 2

Zone 2

Zone 1

YES

YES

YES

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP66

OPERATING TEMPERATURES

Standard Seals - 60°C to +180°C

MATERIALS

Brass CZ121 (EX-50-B)

316 Stainless Steel (EX-50-S)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

18

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Gland Entry Threads

Size

Metric

Entry

Thread

Length

[B]

Max Across

Corners

Max

Protrusion

Length

[A] Min

Gland Seal Range

Cable Inner Sheath [C]

Cable Outer Sheath [D]

Width Thickness Width Thickness

Max Min Max Min Max Min Max

Armor

Acceptance

Range

[X]

20s

20R

20

M20

M20

M20

16

16

16

26.5

33.0

33.0

58.0

58.0

6.3

8.1

11.7

13.5

4.0

5.8

58.0

10.3

13.5

5.6

All Dimensions are in Millimeters

7.0

6.2

9.0

7.9

7.5

11.0

11.7

16.1

13.5

4.5

3.0

4.5

7.0

8.3

9.0

0.1-0.3

0.1-0.45

0.1-0.3

NOTES:

• Gland Size does not necessarily equate to the entry thread size.

• "X" refers to the wire diameter in a braided cable.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• Where EX-50 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

19

ATEX/CSA Approved Glands with Elastometric Seals for Flat Cable

EX-55

EX-55 type glands provide a single pull resistant seal on the outer sheath of unarmoured flat cable. EX-55 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP68 to 25 meters.

EXAMPLE PART NUMBER

EX-55 [W] [Y] [YY] [ZZ]

W -

Gland Material(B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

EX-55-B-3-20S-M20

DESIGN STANDARD

EN50014:1998, EN50018:2000, EN50019:2000 and EN50281-1-1:1998

A D

B

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CERTIFICATE

SIRA 05ATEX1121X - Ex Notified Body No. 0518

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-55-B-3-20S-M20 XX SIRA 05ATEX1121X II 2GD IP68 EExdIIC / EExe II (XX = Year Code)

APPLICATION

EExd Equipment

EX-55 type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume

IIC, IIB, IIA N O Any

IIB, IIA

IIB, IIA

YES

YES

Any

2 litres or less

Which Zone

Zone 1 or 2

Zone 2

Zone 1

Use EX-55 Gland

YES

YES

YES

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP68 @ 25 meters

OPERATING TEMPERATURES

Standard Seal - 60°C to +180°C (Silicone seal)

MATERIALS

Brass CZ121 (EX-55-B)

316 Stainless Steel (EX-55-S)

Outer sheath seal material: Silicone, red or white

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

20

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Gland

Size

Entry Threads

Metric

Entry

Thread

Length

[B]

Max

Across

Corners

[A] Min

Width

Gland Seal Range

Cable Outer Sheath [D]

Thickness

Max Min Max

20s

20R

20

M20

M20

M20

16

16

16

26.5

33.0

6.3

8.1

33.0

10.3

All Dimensions are in Millimeters

11.7

13.5

13.5

4.0

5.8

5.6

7.0

6.2

9.0

NOTES:

• Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• Where EX-55 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

21

ATEX / CSA Approved Compound Filled Barrier Glands

EX-60

EX-60 type glands provide a Flameproof EExd compound filled barrier, a seal on the outer sheath, a universal armor clamp for armored, screened or braided cable and an entry thread seal. The armor clamp provides an electrical bond between the cable armor, screen or braid and the gland. EX-60 type glands maintain EExd

Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant.

EXAMPLE PART NUMBER

EX-60 [W] [Y] [R] [YY] [ZZ]

W -

Gland Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

R -

Reduced bore option

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

EX-60-B-1-R-20S-M20

DESIGN STANDARD

EN50014:1998, EN50018:2000, EN50019:2000 and EN50281-1-1:1998

IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)

A

D

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd I & IIC 4X, Class 1, Zone 1

CERTIFICATE

SIRA 05SIRA1124X - Ex Notified Body No. 0518

Pending

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-60-B-1-R-20S-M20 XX SIRA 05ATEX1124X I M2 II 2GD EExd I & IIC IP68 (XX = Year Code)

B

APPLICATION

EExd Equipment

EX-60 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002

Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-60 Gland

I, IIC, IIB, IIA YES Any Zone 1 or 2 YES

Other Equipment

Mining Equipment Group I, M2

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP66 & IP68 @ 100 Meters

Meets the requirements of DTS01 1991

CURING TIME

@ 21°C

Conductor termination can be effected after 1 hour

The equipment can be energised after 4 hours

The compound chamber can be inspected after 4 hours

OPERATING TEMPERATURES

- 60°C to +85°C

C

22

MATERIALS

Brass CZ121 (EX-60-B)

316 Stainless Steel (EX-60-S)

Inner LSOH compound

Standard outer sheath seal is LSOH silicone, white (EX-60-W-Y)

Reduced bore outer sheath seal is LSOH silicone, red (EX-60-W-Y-R)

Entry thread Seal: Red LSOH silicone

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC)

Gland and accessory kits:

K5- includes gland, locknut, earthtag, integral IP “O” ring & PVC shroud

Gland

Size

Entry Threads Entry

Thread

Length

Max Max

Across Protrusion

Corners Length

Cable Inner

Sheath / Cores [C]

GlandSeal Range

Cable Outer Sheath [D]

Standard Reduced (R)

Armor

Acceptance

Range

Shroud

Size

[B] [A] Max Max

No. of Over

Max

Inner

Min Max Min Max

Metric

M63

M63

M75

M75

M80x2

M85x2

M90x2

M100x2

M32

M40

M50

M50

M20

M20

M20

M25

80

85

90

100

63s

63

75s

75

32

40

50s

50

16

20s

20

25

NPT/BSP

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N6

N6

N7

N7

N8

N8

N8 or N9

N8 or N9

N9 or N10

N9 or N10

88.0

88.0

99.0

99.0

115.2

115.2

125.7

125.7

50.6

60.5

71.5

71.5

28.0

28.0

33.0

41.4

25

25

25

25

19

19

19

19

16

16

16

16

16

16

16

16

72.0

72.0

73.0

83.0

103.0

105.0

115.0

115.0

50

80

100

100

14

25

7

8

9.0

10.4

12.5

17.8

23.5

28.8

34.2

39.4

115.0

115.0

122.0

122.0

120

120

140

140

44.8

50.0

55.4

60.8

50.1

56.0

62.0

68.0

162.0

162.0

166.0

166.0

160

180

200

220

64.4

69.8

75.1

80.5

72.0

78.0

84.0

90.0

All Dimensions are in Millimeters

26.3

32.2

38.2

44.1

11.7

11.7

14.0

20.0

52.1

58.4

64.8

71.1

77.0

79.6

88.0

92.0

26.7

33.0

39.4

45.7

9.0

11.5

15.5

20.3

59.5

65.8

72.2

78.0

84.0

90.0

96.0

102.0

34.0

40.6

46.7

53.2

13.5

16.0

21.1

27.4

-

85.4

-

97.4

54.8

61.2

68.0

73.4

30.5

36.2

42.4

48.5

10.3

12.5

17.6

23.9

47.5

53.8

60.2

66.5

-

75.0

-

87.4

23.2

28.6

34.8

41.1

6.7

9.4

12.0

16.8

0.15 - 1.25

0.15 - 1.25

0.15 - 1.25

0.15 - 1.60

0.15 - 2.00

0.20 - 2.00

0.20 - 2.50

0.20 - 2.50

0.30 - 2.50

0.30 - 2.50

0.30 - 2.50

0.30 - 2.50

0.45 - 3.15

0.45 - 3.15

0.45 - 3.15

0.45 - 3.15

NOTES:

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• If EX-60 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

EL80

EL80

EL90

EL90

L104

L104

L114

L114

L24

L24

EL30

EL38

EL46

EL55

EL65

EL65

23

ATEX / CSA Approved Compound Filled Barrier Glands

EX-65

EX-65 type glands provide a Flameproof EExd compound filled barrier and an entry thread seal. EX-65 type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant.

EXAMPLE PART NUMBER

EX-65 [W] [Y] [YY] [ZZ]

W -

Gland Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

EX-65-B-1-20S-M20

A D

DESIGN STANDARD.

EN50014:1998, EN50018:2000, & EN50281-1-1:1998

IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd I & IIC/Exe II 4X, Class 1, Zone 1

CERTIFICATE

SIRA 05ATEX1124X - Ex Notified Body No. 0518

Pending

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-65-B-1-20S-M20 XX SIRA 05ATEX1124X I M2 II 2GD EExd I & IIC IP68 (XX = Year Code)

B

APPLICATION

EExd Equipment

EX-65 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002

Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-65 Gland

I, IIC, IIB, IIA YES Any Zone 1 or 2 YES

Other Equipment

Mining Equipment Group I, M2

Ignitable Dust, Zones 21 and 22

C

INGRESS PROTECTION

IP66 & IP68 @ 100 Meters

Meets the requirements of DTS01 1991

CURING TIME

@ 21°C

Conductor termination can be effected after 1 hour

The equipment can be energised after 4 hours

The compound chamber can be inspected after 4 hours

OPERATING TEMPERATURES

-60°C to +85°C

24

MATERIALS

Brass CZ121 (EX-65-B)

316 Stainless Steel (EX-65-S)

Inner LSOH compound

Entry thread Seal: Red LSOH silicone

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC)

Gland and accessory kits:

K5- includes gland, locknut, earthtag, integral IP “O” ring & PVC shroud

Gland Size Entry Threads Entry Thread

Length

[B]

Max Across

Corners

[A]

Max

Protrusion

Length

Max

No. of

Cores

Gland Seal Range

Cable Sheath / Cores

Max

Over

Cores [C]

Max

Sheath

Diameter [D]

Shroud Size

Metric NPT/BSP

63

75

80

85

90

100

20s

20

25

32

40

50

M63

M75

M80x2

M85x2

M90x2

M100x2

M20

M20

M25

M32

M40

M50

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N6

N7

N8

N8 or N9

N8 or N9

N9 or N10

N9 or N10

19

19

25

25

25

25

16

16

16

16

16

16

28.0

33.0

41.4

50.6

60.5

71.5

42.0

44.0

48.0

53.0

54.0

54.0

88.0

99.0

115.2

115.2

55.0

60.0

80.0

80.0

125.7

125.7

85.0

85.0

All Dimensions are in Millimeters

120

140

160

180

200

220

8

14

25

50

80

100

50.0

60.8

64.4

69.8

75.1

80.5

10.4

12.5

17.8

23.5

28.8

39.4

56.0

68.0

72.0

78.0

84.0

90.0

11.7

14.0

20.0

26.3

32.2

44.1

NOTES:

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• If EX-65 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

L80

L90

L104

L104

L114

L114

L24

L20

L38

L46

L55

L65

25

ATEX / CSA Approved Compound Filled Barrier Glands

EX-70

EX-70 type glands provide a Flameproof EExd compound filled barrier, a secondary weather seal on the outer sheath and an entry thread seal. EX-70 type glands maintain EExd Flameproof method of explosion protection;

IP66, 68 to 100 meters and is deluge resistant.

EXAMPLE PART NUMBER

EX-70 [W] [Y] [YY] [ZZ]

W -

Gland Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

EX-70-B-1-20S-M20

DESIGN STANDARD

EN50014:1998, EN50018:2000, & EN50281-1-1:1998

IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)

A

D

B

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd I & IIC/Exe II 4X, Class 1, Zone 1

CERTIFICATE

SIRA 05ATEX1124X - Ex Notified Body No. 0518

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-70-1-20S-M20 XX SIRA 05ATEX1124X I M2 II 2GD EExd I & IIC IP68

APPLICATION

EExd Equipment

EX-70 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002

Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume

I, IIC, IIB, IIA YES Any

Which Zone

Zone 1 or 2

Use EX-70 Gland

YES

Other Equipment

Mining Equipment Group I, M2

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP66 & IP68 @ 100 Meters

Meets the requirements of DTS01 1991

CURING TIME

@ 21°C

Conductor termination can be effected after 1 hour

The equipment can be energised after 4 hours

The compound chamber can be inspected after 4 hours

OPERATING TEMPERATURES

-60°C to +85°C

C

26

MATERIALS

Brass CZ121 (Ex-70-B)

316 Stainless Steel (EX-70-S)

Inner LSOH compound

Entry thread Seal: Red LSOH silicone

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC)

Gland and accessory kits:

K5- includes gland, locknut, integral IP “O” ring & PVC shroud

Gland Size Entry Threads Entry

Thread

Length

Max

Across

Corners

Max

Protrusion

Length

Gland Seal Range

Cable Inner

Sheath / Cores [C]

Cable Outer

Sheath [D]

Shroud

Size

Metric

M50

M50

M63

M63

M75

M75

M80x2

M20

M20

M20

M25

M32

M40

M85x2

M90x2

M100x2

50s

50

63s

63

75s

75

80

16

20s

20

25

32

40

85

90

100

NPT/BSP

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N6

N6

N7

N7

N8

N8

N8 or N9

N8 or N9

N9 or N10

N9 or N10

[B]

19

19

25

16

16

19

19

25

25

25

16

16

16

16

16

16

[A] Max

No. of

Cores

71.5

71.5

88.0

88.0

99.0

99.0

115.2

28.0

28.0

33.0

41.4

50.6

60.5

73.0

73.0

73.0

74.0

80.0

87.0

87.0

87.0

88.0

88.0

97.0

97.0

123.0

7

8

14

25

50

80

100

100

120

120

140

140

160

115.2

125.7

123.0

123.0

180

200

125.7

123.0

220

All Dimensions are in Millimeters

Max

Over

Cores

34.2

39.4

44.8

50.0

55.4

60.8

64.4

8.4

10.4

12.5

17.8

23.5

28.8

69.8

75.1

80.5

Max

Sheath

Diameter

38.2

44.1

50.1

56.0

62.0

68.0

72.0

8.4

11.7

14.0

20.0

26.3

32.2

78.0

84.0

90.0

Min Max

38.2

44.1

50.1

56.0

62.0

68.0

72.0

8.4

11.7

14.0

20.0

26.3

32.2

78.0

84.0

90.0

28.2

33.1

39.3

46.7

52.3

58.0

61.9

3.4

4.8

9.5

11.7

18.1

22.6

69.1

74.1

81.8

NOTES:

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• If EX-70 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

EL65

EL65

EL80

EL80

EL90

EL90

L104

L24

L24

EL30

EL38

EL46

EL55

L104

L114

L114

27

ATEX / CSA Approved Compound Filled Barrier Glands

EX-75

EX-75 type glands provide a Flameproof EExd compound filled barrier seal on the cables individual conductors within a conduit. It also provides an entry thread seal. EX-75 type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant.

EXAMPLE PART NUMBER

EX-75 [W] [Y] [YY] [ZZ1] [ZZ2]

W -

Gland Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Gland Size (Cable Range)

ZZ1 -

Male Thread

ZZ2 -

Female Entry Thread

EX-75-B-1-20S-M20

DESIGN STANDARD

EN50014:1998, EN50018:2000, & EN50281-1-1:1998

IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)

CERTIFICATION

ATEX II 2 GD, E Exd IIC / E Exe II

CSA Exd I & IIC/Exe II 4X, Class 1, Zone 1

A D

MATING CONDUIT OR

CABLE GLAND

CERTIFICATE

SIRA 03ATEX1479X - Ex Notified Body No. 0518

GLAND MARKING

CENELEC and ATEX

Example:

Amphenol 13838 USA EX-75-B-1-20S-M20 XX SIRA05ATEX1120X I M2 II 2GD EExd I & IIC IP68

B

APPLICATION

EExd Equipment

EX-75 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002

Section 10.4.2

Gas Group Internal Ignition Source Enclosure Volume

I, IIC, IIB, IIA YES Any

Which Zone

Zone 1 or 2

Use EX-75 Gland

YES

Other Equipment

Mining Equipment Group I, M2

Ignitable Dust, Zones 21 and 22

INGRESS PROTECTION

IP66 & IP68 @ 100 Meters

Meets the requirements of DTS01 1991

CURING TIME

@ 21°C

Conductor termination can be effected after 1 hour

The equipment can be energised after 4 hours

The compound chamger can be inspected after 4 hours

OPERATING TEMPERATURES

-60°C to +85°C

C

28

MATERIALS

Brass CZ121 (EX-75-B)

316 Stainless Steel (EX-75-S)

Inner LSOH compound

Entry thread Seal: Red LSOH silicone

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Fitting

Size

Ref

Male Entry Female Entry Entry

Thread

Length

Max

Across

Corners

Max

Protrusion

Length

Sealing Range

Cable Conductors / Cores

20

25

32

40

50

63

75

80

85

90

100

Metric

M20

M25

M32

M40

M50

M63

M75

M80x2

M85x2

M90x2

M100x2

NPT

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N6

N7

N8

N8 or N9

N8 or N9

N9 or N10

N9 or N10

Metric

M20

M25

M32

M40

M50

M63

M75

M80x2

M85x2

M90x2

M100x2

NPT [B] [A]

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N6

N7

16

16

16

16

16

19

33.0

41.4

50.6

60.5

71.5

88.0

N8

N8 or N9

N8 or N9

N9 or N10

19

25

25

25

99.0

115.2

115.2

125.7

78.0

103.0

103.0

104.0

N9 or N10 25 125.7

All Dimensions are in Millimeters

104.0

57.0

63.0

67.0

68.0

68.0

72.0

Max

No. of

Cores

14

25

50

80

100

120

140

160

180

200

220

Max

Over

Cores [C]

12.5

17.8

23.5

28.8

39.4

50.0

60.8

64.4

69.8

75.1

80.5

NOTES:

• NPT thread reference details on page 53.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads.

• If EX-75 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system.

• The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation.

• To maintain ingress protection a thread sealant should be applied to the conduit thread.

• Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full.

Max Cable

Inside Fitting

[D]

14.0

20.0

26.3

32.2

44.1

56.0

68.0

72.0

78.0

84.0

90.0

29

Non-Hazardous Industrial Glands

CGA

CGA type glands provide an integral armor clamp for armored cable. The integral armor clamp provides an electrical bond between the cable armor and the gland. CGA type glands maintain IP30.

EXAMPLE PART NUMBER

CG[X] [W] [Y] [YY] [ZZ]

X -

Clamp Type (See Clamps)

W -

Gland Material ( B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

Sample: CGA-B-3-20S-M20

DESIGN STANDARD

BS 6121:1989

A

D

B

GLAND MARKING

Example:

BS6121 Part 1 CGA-B-3-20S-M20 Amphenol

OPERATING TEMPERATURES

-100°C to +600°C

INGRESS PROTECTION

IP30

MATERIALS

Brass CZ121 (CGA-B)

VARIATIONS

All variants of the CGA type gland feature a separate armor clamping ring to allow for inspection of the clamped armor:

Brass (CGA-B)

THREADS

ISO Metric only

CLAMPS

SWA Clamping using gland body (CGA)

SWA steel wire armor - clamping ring (CGL)

SWB woven steel wire armor or STA steel tape armor - clamping ring (CGZ)

ACCESSORIES

Locknut - Brass (EX-BLN); Steel (EX-MLN)

Earth Tag - Brass (EX-BET)

Shroud - PVC (EX-PVC)

Gland and accessory kits:

K6- includes gland, steel locknut, earthtag and PVC shroud

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless

Nickel (4)

D

30

Gland Entry

Size Threads

Entry

Threads

Length

M<ax

Across

Corners

Max

Protrusion

Length

Cable Inner

Gland Seal Range

Cable Outer

Sheath [C] Sheath [D]

Armor Acceptance

Range

Metric [B] [A] Min Max Min Max W

40

50

63

75

20s

20

25

32

80

85

90

100

M40

M50

M63

M75

M20

M20

M25

M32

M80

M85

M90

M100

15

15

15

15

10

10

10

10

20

20

20

20

60.5

71.5

88.0

99.0

24.2

29.7

45.1

50.6

115.2

115.2

125.7

125.7

30.0

32.0

42.0

50.0

20.0

20.0

22.0

25.0

50.0

50.0

50.0

50.0

-

-

-

-

-

-

-

11.7

14.0

20.0

26.3

32.2

44.1

56.0

68.0

-

-

-

72.0

78.0

84.0

90.0

-

-

-

-

All Dimensions are in Millimeters

-

-

-

-

-

-

-

-

40.6

53.2

65.8

78.0

16.0

21.0

27.4

34.0

84.0

90.0

96.0

102.0

0.90-1.25

0.90-1.25

1.25-1.60

1.60-2.00

1.60-2.00

2.00-2.50

2.50

2.50

3.15

3.15

3.15

3.15

NOTES:

• Gland Size does not necessarily equate to the entry thread size

• "W" refers to the wire diameter in a steel wire armored cable

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

• Shroud sizes above are for CGA type only.

• Full assembly instructions are available upon request, the instructions should be read prior to installation and adhered to in full

XZ

Clamp Ring

Version Only

0.15-0.35

0.15-0.50

0.15-0.50

0.15-0.55

0.20-0.60

0.20-0.60

0.30-0.80

0.30-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

Shroud

Size

L55

L65

L80

L90

S22

S27

S36

S41

S104

S104

S114

S114

31

Non Hazardous Industrial Glands

CGSB and CGSS type glands provide a seal on the outer sheath and an armor specific clamp for armored cable.

The armor clamp provides an electrical bond between the cable armor and the gland; and maintain IP66 rating.

EXAMPLE PART NUMBER

CGSB* [W] [Y] [R] [YY] [ZZ]

* -

Armor Type (W = SWA / X = SWB / Z = STA)

W -

Seal Material (1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

R -

Reduced bore option

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

Sample: CGSB-W-1-3-R-20S-M20

A

D

B

DESIGN STANDARD

BS EN 50262: 1999

GLAND MARKING

Example:

CGSB-W-1-3-R-20S-M20 Amphenol

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +200°C

INGRESS PROTECTION

IP66

MATERIALS

Brass CZ121 (CGSB)

316 Stainless Steel (CGSS)

Outer sheath seal material: Standard Neoprene, black. Option Silicone, white

Reduced bore outer sheath seal (R) Silicone, red

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel);

SEALS

Extended operating temperature -60°C to +200°C, halogen free versions:

Brass (CGSB-*-3); 316 Stainless Steel (CGSS-*-3)

CLAMPS

SWA steel wire armor (CGSB-W)

SWB woven steel wire armor or STA steel tape armor (CGSB-X)

SWA, SWB and STA armor clamps (CGSB-Z)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC); PCP (EX-SPCP); Low Smoke Zero Halogen (EX-LSH)

Gland and accessory kits:

K7- includes gland, locknut, earthtag and PVC shroud

K8 - includes brass gland, brass locknut, brass earthtag and zero halogen shroud

C

32

Gland

Size

Entry Threads Entry Max Max

Thread Across Protrusion

Length Corners

[B] [A]

Length

Cable Inner

Sheath [C]

Min Max

Gland Seal Range

Cable Outer Sheath [D]

Min

Standard

Max

Reduced (R)

Min Max

Armour Acceptance

Range

Shroud

Size

Metric NPT/BSP

50s

50

63s

63

75s

75

16

20s

20

25

32

40

80

80H

85

90

90H

100

M50

M50

M63

M63

M75

M75

M20

M20

M20

M25

M32

M40

M80 x 2

M80 x 2

M85 x 2

M90 x 2

M90 x 2

M100 x 2

71.5

71.5

88.0

88.0

99.0

99.0

26.5

26.5

33.0

41.4

50.6

60.5

115.2

115.2

115.2

125.7

125.7

125.7

15

15

15

15

15

15

10

10

10

10

10

15

20

20

20

20

20

20

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

N7

N7 or N8

N8

N8 or N9

N8 or N9

N8 or N9

N9 or N10

N9 or N10

N9 or N10

-

-

-

-

-

-

-

-

-

-

-

-

67.0

67.0

69.0

69.0

77.0

77.0

54.0

54.0

54.0

54.0

60.0

67.0

11.7

11.7

14.0

20.0

26.3

32.2

38.2

44.1

50.1

56.0

62.0

68.0

104.0

104.0

104.0

104.0

-

-

-

72.0

72.0

78.0

84.0

77.0

79.6

79.6

88.0

84.0

90.0

90.0

96.0

104.0

104.0

-

-

84.0

90.0

92.0

92.0

All Dimensions are in Millimeters

102.0

102.0

39.4

45.7

52.1

58.4

64.8

71.1

9.0

11.5

15.5

20.3

26.7

33.0

46.7

53.2

59.4

65.8

72.2

78.0

13.5

16.0

21.0

27.4

34.0

40.6

6.7

9.4

10.3

W

0.90

12.5

0.90-1.25

12.0

17.6

0.90-1.25

16.8

23.9

1.25-1.60

23.2

30.5

1.60-2.00

28.6

36.2

1.60-2.00

34.8

42.4

2.00-2.50

41.1

48.5

2.00-2.50

47.5

54.8

53.8

61.2

2.50

2.50

60.2

68.0

66.5

73.4

2.50

2.50

-

-

-

-

75.0

85.4

-

-

87.4

97.4

3.15

3.15

3.15

3.15

3.15

3.15

XZ

0.15-0.35

0.15-0.35

0.15-0.50

0.15-0.50

0.15-0.55

0.20-0.60

0.20-0.60

0.30-0.60

0.30-0.80

0.30-0.80

0.30-1.00

0.30-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

NOTES:

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• "W" refers to the wire diameter in a steel wire armored cable.

• "XZ" refers to the wire diameter in a woven steel wire armored cable or the tape thickness in a steel tape armored cable.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• Full assembly instructions are available upon request, the instructions should be read prior to installation and adhered to in full.

L65

L65

L80

L80

L90

L90

L24

L24

L30

L38

L46

L55

L104

L104

L104

L114

L114

L114

33

Non Hazardous Industrial Glands

CDGS type glands provide a seal on the inner sheath, a seal on the outer sheath and an armor specific armor clamp for armored cable. The armor clamp provides an electrical bond between the cable armor and the gland.

CGDS type glands maintain IP66, IP67.

EXAMPLE PART NUMBER

CGDS* [W] [Y] [R] [YY] [ZZ]

* -

Armor Type (W = SWA / X = SWB / Z = STA)

W -

Gland Material (B = Brass / S = Stainless Steel)

X -

Seal Type ( 0 = None / 1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

R -

Reduced bore option

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

Sample: CGDS-W-B-0-3-R-20S-M20-K1

A D

B

C

DESIGN STANDARD

BS EN 50262: 1999

GLAND MARKING

Example:

CDGS-W-B-0-3-R-20S-M20 Amphenol

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +200°C

INGRESS PROTECTION

IP66 and IP67

MATERIALS

Brass CZ121 (CGDS-*-B)

316 Stainless Steel (CGDS-*-S)

Inner and outer sheath seal material: Standard Neoprene, black. Option Silicone, white

Reduced bore outer sheath seal (R) Silicone, red

VARIATIONS

Omission of outer seal:

Brass (CDGS-*-B-0); 316 Stainless Steel (CDGS-*-S-0)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

CLAMPS

SWA steel wire armor (CGDS-W)

SWB woven steel wire armor (CGDS-X)

STA steel tape armor (CGDS-Z)

SEALS

Extended operating temperature -60°C to +200°C, halogen free versions:

Brass (CDGS-*-B-3); 316 Stainless Steel (CDGS-*-S-3)

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

34

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH)

Gland and accessory kits:

K1 - includes gland, locknut, earthtag and PVC shroud

K8 - includes brass gland, brass locknut, brass earthtag and zero halogen shroud

Gland

Size

Entry Threads Entry Max Max

Thread Across Protrusion

Length Corners Length

[B] [A]

Cable Inner

Sheath [C]

Min Max

Gland Seal Range

Cable Outer Sheath [D]

Standard

Min Max

Reduced (R)

Min Max

Armour Acceptance

Range

Shroud

Size

32

40

50s

50

63s

63

75s

16

20s

20

25

75

80

80H

85

90

90H

100

Metric

M32

M40

M50

M50

M63

M63

M75

M20

M20

M20

M25

M75

M80 x 2

M80 x 2

M85 x 2

M90 x 2

M90 x 2

M100 x 2

NPT/BSP

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

N7

N7 or N8

N8

N8 or N9

N8 or N9

N8 or N9

N9 or N10

N9 or N10

N9 or N10

50.6

60.5

71.5

71.5

88.0

88.0

99.0

26.5

26.5

33.0

41.4

99.0

115.2

115.2

115.2

125.7

125.7

125.7

19

19

19

16

16

16

16

16

16

16

16

25

25

25

19

25

25

25

65.0

72.0

73.0

73.0

76.0

76.0

82.0

58.0

58.0

58.0

58.0

19.0

25.0

31.5

36.5

42.5

49.5

54.5

4.0

8.0

6.7

*

13.0

26.3

32.2

38.2

44.1

50.1

56.0

62.0

8.4

11.7

14.0

20.0

82.0

110.0

110.0

110.0

110.0

110.0

110.0

60.5

62.2

62.2

69.0

74.0

74.0

82.0

68.0

72.0

72.0

78.0

84.0

84.0

90.0

All Dimensions are in Millimeters

71.1

77.0

79.6

79.6

88.0

92.0

92.0

26.7

33.0

39.4

45.7

52.1

58.4

64.8

8.4

11.5

15.5

20.3

34.0

40.6

46.7

53.2

59.4

65.8

72.2

13.5

16.0

21.0

27.4

78.0

84.0

90.0

90.0

66.5

73.4

-

-

75.0

85.4

96.0

102.0

-

-

-

-

102.0

87.4

97.4

4.9

9.4

10.0

12.5

12.0

17.6

16.8

23.9

23.2

30.5

28.6

36.2

34.8

42.4

41.1

48.5

47.5

54.8

53.8

61.2

60.2

68.0

W

0.90

0.90-1.25

0.90-1.25

1.25-1.60

2.50

3.15

3.15

3.15

3.15

3.15

3.15

1.60-2.00

1.60-2.00

2.00-2.50

2.00-2.50

2.50

2.50

2.50

XZ

0.15-0.35

0.15-0.35

0.15-0.50

0.15-0.50

0.15-0.55

0.20-0.60

0.20-0.60

0.30-0.80

0.30-0.80

0.30-0.80

0.30-1.00

0.30-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

0.45-1.00

NOTES:

* CGDS gland size 20, the silicone inner seal only seals to a minimum of 11.0mm and NOT 6.7mm.

• NPT entry thread reference on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• "W" refers to the wire diameter in a steel wire armored cable.

• "XZ" refers to the wire diameter in a woven steel wire armored cable or the tape thickness in a steel tape armored cable.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• Full assembly instructions are available upon requests, the instructions should be read prior to installation and adhered to in full.

L46

L55

L65

L65

L80

L80

L90

L24

L24

L30

L38

L90

L104

L104

L104

L114

L114

L114

35

Non Hazardous Industrial Glands

CGU type glands provide a single pull resistant seal on the outer sheath of unarmoured cable. CGU type glands maintain IP66, IP68 to 25 meters.

EXAMPLE PART NUMBER

CGU [W] [Y] [YY] [ZZ]

W -

Gland Material (B = Brass / S = Stainless Steel)

X -

Seal (1 = Neoprene / 3 = Silicone)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Gland Size (Cable Range)

ZZ -

Entry Thread

Sample: CGU-B-1-3-20S-M20

DESIGN STANDARD

BS EN 50262: 1999

GLAND MARKING

Example:

CGU-B-1-3-20S-M20

OPERATING TEMPERATURES

Standard Seals -20°C to +80°C

Silicone Seals - 60°C to +200°C

MATERIALS

Brass CZ121 (CGU-B)

316 Stainless Steel (CGU-S)

Outer sheath seal material:

Standard Neoprene, black. Option Silicone, white

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP

Parallel);

A D

INGRESS PROTECTION

IP66 and IP68 @ 25 metres

B

SEALS

Extended operating temperature -60°C to +200°C, halogen free versions:

Brass (CGU-B-3); 316 Stainless Steel (CGU-B-3);

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

ACCESSORIES

Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN)

Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET)

IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW)

Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW)

Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH)

Gland and accessory kits:

K9 - includes gland, locknut and PVC shroud

36

Gland Size Entry Threads Entry Thread

Length

[B]

Max Across

Corners

[A]

Max

Protrusion

Length

Gland Seal Range

Cable Outer/Lead Sheath

[D[

Min Max

Shroud Size

Metric NPT/BSP

50s

50

63s

63

75s

75

80

85

90

100

16

20s

20

25

32

40

M50

M50

M63

M63

M75

M75

M20

M20

M20

M25

M32

M40

M80 x 2

M85 x 2

M90 x 2

M100 x 2

N1 or N2

N1 or N2

N1 or N2

N2 or N3

N3 or N4

N4 or N5

N5 or N6

N6

N6 or N7

N7

N7 or N8

N8

N8 or N9

N8 or N9

N9 or N10

N9 or N10

16

16

19

19

19

19

16

16

16

16

16

16

28.0

28.0

33.0

41.4

50.6

60.5

71.5

71.5

88.0

88.0

99.0

99.0

25

25

25

25

115.2

115.2

125.7

125.7

All Dimensions are in Millimeters

50.0

50.0

50.0

50.0

33.0

33.0

33.0

33.0

33.0

37.0

37.0

37.0

37.0

37.0

37.0

37.0

28.2

33.2

39.3

46.7

52.3

58.1

62.3

69.1

74.1

82.1

4.0

7.2

9.6

13.5

19.5

23.0

NOTES:

• NPT entry thread reference details on page 53.

• Gland Size does not necessarily equate to the entry thread size.

• Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

• Full assembly instructions are avalable upon request, the instructions should be read prior to installation and adhered to in full.

38.2

44.1

50.1

56.0

62.0

68.0

72.0

78.0

84.0

90.0

8.4

11.7

14.0

20.0

26.3

32.2

L65

L65

L80

L80

L90

L90

L104

L104

L114

L114

L24

L24

L30

L38

L46

L55

37

Accessories: Adaptors and Reducers

EXR Series Dual Certified Adaptors and Reducers provide a method of matching electrical thread forms on Ex equipment while maintaining Flameproof Exd and Increased Safety Exe methods of explosion protection and

IP66, 68 for IEC type applications. Class I, Division 1 and NEMA 4X, 6P for NEC/CEC type applications.

EXAMPLE PART NUMBER

EXR [W] [Y] [ZZ1] [ZZ2] Sample: EXR-B-0-M20-M20

W -

Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

ZZ1 -

Male Thread

ZZ2 -

Female Entry Thread

CERTIFICATION

CENELEC

SIRA 00ATEX 1094 (Metric Female)

SIRA 99ATEX 1115U (Non-Metric Female)

I M2 II 2DG E Ex de IandIIC

CSA / A Ex

Class I, Zone 1, Ex de IandIIC

Class I, Division 1and2 ABCD

Class II EFG, Class III

GOST R-Exde IICU

POCC GB 05.B00482

INGRESS PROTECTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

IMPACT RESISTANCE

20Nm

OPERATING TEMPERATURES

-50°C to +85°C

MATERIALS

Brass CZ121 (EXR-B)

316 Stainless Steel (EXR-S)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel);

SEALS

The standard 'O' Ring material is Nitrile.

Tapered male thread options are not normally supplied c/w ‘O’ ring seal, thread sealant should be used to maintain the desired level of ingress protection

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

38

Metric

M16

M20

M25

M32

M40

M50

M63

M75

M80 x 2.0

M85 x 2.0

M90 x 2.0

M100 x 2.0

Bore

41.0

53.0

64.0

69.0

73.0

78.0

88.0

10.0

14.0

18.0

24.0

32.0

NPT

N5

N6

N7

N8

N9

N10

N1

N2

N3

N4

SIZES AVAILABLE AND DIMENSION REFERENCES

Bore ISO Pipe Bore Et Bore

38.0

49.0

60.0

75.0

88.0

100.0

15.0

1/2" 15.0

3/4" 14.0

19.0

25.0

32.0

3/4"

1"

N4

19.0

25.0

32.0

1"

N4

11/2"

18.0

24.0

32.0

11/2"

2"

N7

3"

31/2"

4"

38.0

49.0

60.0

75.0

88.0

100.0

2"

N7

3"

41.0

53.0

64.0

All Dimensions are in Millimeters

NOTES:

• Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and adhered to in full

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

• For Flameproof Exd applications the female thread into which the adaptor or reducer is to be fitted must comply with clause 5.3 of EN

50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads

• For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full threads must be achieved for tapered threads

• Where EXR adaptors and reducers are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system

• 316 Stainless Steel versions do not feature a marking band. This reduces the overall length of reducers by 5mm, it does not affect the overall length of Adaptor

• Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the entry thread of the enclosure

• Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread

39

Accessories: Nylon Adaptors and Reducers

EXRN

EXRN Series Certified Adaptors and Reducers provide a method of matching electrical threadforms on Ex equipment while maintaining Increased Safety Exe methods of explosion protection and IP66, 68 for IEC type applications.

Adaptors

are used where the thread size of the cable gland or connection device is larger than, or of equivalent size to the entry thread of the enclosure.

Reducers

are used to reduce the entry thread of an enclosure to acept a cable gland or connection device with a smaller thread.

EXAMPLE PART NUMBER

EXRN [ZZ1] [ZZ2]

ZZ1 -

Male Thread

ZZ2 -

Female Entry Thread

Sample: EXRN-M20-M25

CERTIFICATION

CENELEC

SIRA 00ATEX 3091 (Metric Female)

SIRA 99ATEX 3116U (Non-Metric Female)

II 2DG E Ex e II

CSA / A Ex

Class I, Zone 1, Ex e II

Class I, Division 2 ABCD

Class II EFG, Class III

INGRESS PROTECTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

OPERATING TEMPERATURES

-50°C to +85°C

IMPACT RESISTANCE

7Nm

MATERIALS

30% Glass Filled Nylon (EXRN)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

SEALS

The standard 'O' Ring material is Nitrile

40

SIZES AVAILABLE AND DIMENSION REFERENCES

Bore ISO Pipe Bore Metric Bore NPT ET Bore

M16

M20

M25

M32

M40

M50

9.3

11.0

16.0

21.0

31.0

40.0

N1

N2

N3

N4

N5

12.0

I1 12.0

E2 11.0

13.0

18.0

I2

I3

13.0

18.0

E3

E4

16.0

21.0

33.0

I4

38.0

I5

All Dimensions are in Millimeters

33.0

38.0

E5

E6

31.0

40.0

NOTES:

• Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and adhered to in full

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

• Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the entry thread of the enclosure

• Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread

41

Accessories: Insulating Adaptors

EXIA series Insulated Adaptors provide a method of insulating the cable gland or connection device from the equipment into which it has been installed. EXIA series Insulated Adaptors maintain Flameproof Exd method of explosion protection and IP66, 68 for IEC type applications. Class I, Division 1 and NEMA 4X, 6P for NEC/CEC type applications.

EXAMPLE PART NUMBER

EXIA [W] [X] [ZZ1] [ZZ2]

W -

Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc /

4 = Electroless Nickel)

ZZ1 -

Male Thread

ZZ2 -

Female Entry Thread (See NPT reference data on page 53)

Sample:EXIA-B-1-M20-N1

CERTIFICATION

CENELEC

SIRA 00ATEX 1098 (Metric Female)

SIRA 99ATEX 1117U (Non-Metric Female)

II 2DG E Ex d IIC

CSA / A Ex

Class I, Zone 1, Ex d IIC

Class I, Division 2 ABCD

Class II EFG, Class III

GOST R-Exde IICY

POCC GB 05.B00482

APPLICATION

To avoid relying on the contact between cable termination and equipment enclosure for grounding the cable armor, an insulated adaptor can be fitted to both ends of the cable with a grounding device (i.e. earth tag/lug) fitted between the adaptor and the termination. The armor current can then be taken from the grounding device to ground in a controlled, positive manner that can be inspected easily.

Single Point Grounding

- In many application it is sufficient to ground the cable armor at one end. For single point grounding the insulated adaptors would again be used at both ends of the cable but with the earth tag fitted only to the end where grounding is required.

Single Point Grounding can

- reduce the circulating currents that can cause heating of high capacity cables.

- reduce the risk of damage to electronic equipment within the enclosure in the even of a short circuit to ground through the enclosure.

- reduce the problems of electrical noise on the armor affecting the clean earth required for some sensitive instruments.

Electrical properties of insulating material

- Dielectric strength: 90KV/mm

- Volume resistivity: 8.6 x 10x14 O/cm

- Minimum thickness of insulator: 5mm +/- 1mm

- 2KV 'Wet Withstand' Tested

INGRESS PROTECTION

IP54, CSA Enclosure Type (NEMA) 3

IP66 68 can be maintained with the use of either IP washers or a non-hardening thread sealant

OPERATING TEMPERATURES

-50°C to +85°C

42

MATERIALS

Brass CZ121 (EXIA-B)

316 Stainless Steel (EXIA-S)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

IMPACT RESISTANCE

7Nm

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

Metric

M20

M25

M32

M40

M50

M63

M75

M80 x 2.0

M85 x 2.0

M90 x 2.0

Hex A/F

30.5

37.6

47.2

55.9

70.1

80.0

95.3

100.0

106.4

106.4

SIZES AVAILABLE AND DIMENSION REFERENCES

Hex A/C Total Length Male Length

35.5

43.2

54.3

64.1

80.8

92.0

54.0

54.0

54.0

54.0

54.0

54.0

109.5

114.0

114.0

114.0

54.0

63.0

63.0

63.0

All Dimensions are in Millimeters

16.0

16.0

16.0

16.0

16.0

16.0

16.0

20.0

20.0

20.0

Female Depth

17.0

17.0

17.0

17.0

17.0

17.0

17.0

22.0

22.0

22.0

NOTES:

• Full installation instructions are supplied with insulated adaptors, the instructions must be read prior to installation and adhered to in full

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

• For Flameproof Exd applications the female thread into which the adaptor is to be fitted must comply with clause 5.3 of EN

50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads

Bore

13.5

19.0

25.0

30.0

40.5

53.0

65.0

70.0

75.0

80.0

43

Accessories: Stopping Plugs

EXSPH Stopping Plugs

EXSPH Series Dual Certified Metallic Dome Head Stopping Plugs provide a method of filling unused entries in

Ex equipment while maintaining Flameproof Exd and Increased Safety Exe methods of explosion protection and

IP66, 68 for IEC type applications. Class I, Division 1 and NEMA 4X, 6P for NEC/CEC type applications.

EXAMPLE PART NUMBER

EXSPH [W] [Y] [ZZ]

W -

Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

ZZ -

Male Entry Thread

Sample: EXSPH-B-1-M20

CERTIFICATION

CENELEC

SIRA 00ATEX1094 I M2 II 2DG E Ex de IandIIC

CSA / A Ex

Class I, Zone 1, Ex de IandIIC

Class I, Division 1and2 ABCD

Class II EFG, Class III

GOST R-Exde IICY

POCC GB 05.B00482

INGRESS PROTCTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

OPERATING TEMPERATURES

-50°C to +85°C

IMPACT RESISTANCE

20Nm

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

MATERIALS

Brass CZ121 (SPMH-B)

316 Stainless Steel (SPMH-S)

SEALS

The standard 'O' Ring material is Nitrile

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

44

Metric

M16

M20

M25

M32

M40

M50

M63

M75

M80 x 2.0

M85 x 2.0

M90 x 2.0

M100 x 2.0

Dim Ref

D

D

B

B

D

D

B

B

A

B

B

B

SIZES AVAILABLE AND DIMENSION REFERENCES

NPT Dim Ref

N1

N2

N3

N4

N5

N6

N7

N8

N9

N10

ISO Pipe Dim Ref

F

F

E

F

F

E

E

C

E

C P1 C

P2

P3

C

C

P4

P5

C

C

P6

P7

P8 C

C

C

Dimension Reference

Head Diameter

Hex Socket A/F

Total Length

Thread Length

A

8.0

21.5

16.0

DIMENSIONS

C B D

Minimum 6.0mm larger than the major thread diameter

10.0

10.0

10.0

21.5

16.0

24.5

19.0

All Dimensions are in Millimeters

25.5

22.0

E

10.0

29.0

23.5

F

10.0

39.0

33.5

NOTES:

• EXSPH type stopping plugs are designed for use within either clearance holes or parallel threaded entries, for taper threaded entries we would recommend the use of EXSP type stopping plugs on page 48.

• Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in full

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

• For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN 50018:2000

(clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads

• For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full threads must be achieved for tapered threads

• Where metallic stopping plugs are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system

45

Accessories: Stopping Plugs

EXSPHN Series Glass Filled Nylon Dome Head Stopping Plugs provide a method of filling unused entries in increased safety equipment, maintaining Increased Safety Exe methods of explosion protection and IP66, 68 for

IEC type applications.

EXAMPLE PART NUMBER

EXSPHN [ZZ]

ZZ -

Male Thread size

Sample: EXSPHN-M20

CERTIFICATION

CENELEC

SIRA 00ATEX3091 II 2DG E Ex eII

CSA / A Ex

Class I, Zone 1, Ex e II

Class I, Division 2 ABCD

Class II EFG, Class III

INGRESS PROTECTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

OPERATING TEMPERATURES

-50°C to +85°C

MATERIALS

30% Glass Filled Nylon (SPMHN)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP

Parallel); PG

IMPACT RESISTANCE

7Nm

SEALS

The standard 'O' Ring material is Nitrile

46

Metric

M16

M20

M25

M32

M40

M50

M63

M75

Dimension Reference

Head Diameter

Hex Socket A/F

Total Length

Thread Length

SIZES AVAILABLE AND DIMENSION REFERENCES

Dim Ref NPT

C

C

C

C

C

B

C

C

N1

N2

N3

N4

N5

N6

N7

DIMENSIONS

A B

6.0

21.5

16.0

Minimum 6.0mm larger than the major thread diameter

8.0

21.5

16.0

All Dimensions are in Millimeters

Dim Ref

F

F

F

F

G

D

D

C

10.0

21.5

16.0

NOTES:

• EXSPHN type stopping plugs are designed for use within either clearance holes or parallel threaded entries, for taper threaded entries we would recommend the use of EXSP type stopping plugs on page 48.

• Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and adhered to in full.

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch.

47

Accessories: Stopping Plugs

EXSP T ype Stopping Plug

EXSP Series Certified Metallic Stopping Plugs provide a method of filling unused entries in Ex equipment, maintaining Flameproof Exd method of explosion protection and IP54 for IEC type applications. Class I, Division 1 and NEMA 3 for NEC/CEC type applications.

EXSP-A Type - Externally accessible hexagon recess

EXSP-B Type - Internally accessible hexagon recess

EXAMPLE PART NUMBER

EXSP [T] [W] [Y] [ZZ]

T -

Type (A = Type A / B = Type B)

W -

Material (B = Brass / S = Stainless Steel)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

ZZ -

Male Thread Size

Sample: EXSP-A-B-1-M20

CERTIFICATION

CENELEC

SIRA 99ATEX1113 II 2DG E Ex d IIC

CSA / A Ex

Class I, Zone 1, Ex d IIC

Class I, Division 1and2 ABCD

Class II EFG, Class III

INGRESS PROTECTION

IP54, CSA Enclosure Type (NEMA) 3

OPERATING TEMPERATURES

-50°C to +85°C

MATERIALS

Brass CZ121 (EXSP-T-B)

316 Stainless Steel (EXSP-T-S)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

IMPACT RESISTANCE

7Nm

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4)

48

Metric

M16

M20

M25

M32

M40

M50

M63

M75

M80 x 2.0

M85 x 2.0

M90 x 2.0

M100 x 2.0

Dim Ref

A

B

B

B

B

B

B

B

F

F

F

F

SIZES AVAILABLE AND DIMENSION REFERENCES

NPT Dim Ref

N1

N2

N3

N4

N5

N6

N7

N8

N9

N10

ISO Pipe Dim Ref

D

D

F

D

D

C

C

F

F

F

P1

P2

P3

P4

P5

P6

P7

P8

E

E

G

G

G

G

G

G

Dimension Reference

Hex Socket A/F

Length (min)

A

8.0

17.0

DIMENSIONS

C B D

10.0

17.0

10.0

14.0

All Dimensions are in Millimeters

10.0

16.0

E

10.0

18.0

F

10.0

22.0

NOTES:

• Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in full

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

• For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN

50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads

• For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full threads must be achieved for tapered threads

G

10.0

25.0

49

Accessories: Breather Drain

EXBD Series Breather Drain provides a method of effectively draining any moisture within an enclosure whilst allowing the air inside the enclosure to breathe with the surrounding atmosphere. EXBD series breather drains maintain Increased Safety Exe method of explosion protection and IP66 for IEC type applications.

EXAMPLE PART NUMBER

EXBD [W] [Y] [ZZ]

W -

Material (B = Brass / S = Stainless Steel / N = 30% Glass Filled

Nylon)

Y -

Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 =

Electroless Nickel)

YY -

Male Thread

ZZ -

10 or 15

Sample: EXBD-B-0-M20-15

CERTIFICATION

CENELEC

SIRA99ATEX3050U I M2 II 2DG EExe I/II; II 2DG E Exe (Glass Filled

Nylon)

CSA / A Ex

Class I, Zone 1, Exe II; Class I Division 2, Groups ABCD

GOST R-Exde IICY

POCC GB 05.B00482

Internal

Dust Seal

Captive

'O' Ring Seal

Moisture

Moisture Out

Air In

Castellated

Locknut

External

Drainage

APPLICATION

Internal Dust Sea

l provides ingress protection to IP66 and 4x, with the largest possible pore size to aid draining, whilst retaining filtration capabilities that remove debris from the moisture and retains it on the surface where it can easily be removed with compressed air.

Additionally the structural strength and chemical resistance characteristics of the material enable the filter to meet the requirements of hazardous area installations

Castellated Locknut

allows moisture to pass between the locknut and the enclosure, draining via holes in the thread without any build up of moisture in the bottom of the enclosure

Captive 'O' Ring Sea

l is located within a recess on the face of the breather drain again optimising ingress protection, ensuring the 'o'ring is not displaced during installation and helping protect the 'O' ring from the environmental damage

External Drainage

via two ports optimises ingress protection without compromising the draining capabilities

INGRESS PROTECTION

IP66, CSA Enclosure Type 4x, NEMA 4x

IMPACT RESISTANCE

20Nm. (7Nm GF Nylon)

OPERATING TEMPERATURES

-50°C to +85°C

MATERIALS

Brass CZ121 (EXBD-B)

316 Stainless Steel (EXBD-S)

30% Glass Filled Nylon (EXBD-N)

VARIATIONS

Clearance Hole: 10mm length of thread, supplied complete with a castellated locknut and having 2 holes in the thread wall positioned directly opposite each other (EXBD-W-Y-YY-10)

Threaded Entry: 15mm length of thread, either supplied with castellated locknut (EXBD-W-Y-YY-15) or without castellated locknut (EXBD-W-Y-

YY-15NL) and having 3 holes in the thread wall, offset to provide a 9mm range to accommodate differing wall thickness.

50

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread

(BSP Taper, BSP Parallel); PG

SEALS

The standard 'O' Ring material is Nitrile

PLATING

Nickel (1); Tin (2); Zinc (3); Electroless

Nickel (4)

Size

M20 - N1

M25 - N2

Hex A/F

28.6mm

34.9mm

DIMENSIONAL DATA

Thread Length Hex A/C

32.9mm

10 (2 Hole) or 15 (3 Hole)

40.2mm

All Dimensions are in Millimeters

Head Length

15mm

NOTES:

• 30% glass filled nylon variations are only available with 15mm length of thread version and are supplied with or without a brass castellated nut

• Full installation instructions are supplied with the breather drain, the instructions must be read prior to installation and adhered to in full

• Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

• Where metallic breather drains are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system

51

Accessories: General

A full range of accessories including locknuts, earthtags, sealing washers, serrated washers and shrouds for use with all our cable glands

AVAILABILITY

ACCESSORY TYPE GLAND TYPES/SIZE

METRIC NPT

Locknuts

provide a method of securing a threaded entry component into a piece of equipment

Brass (EX-BLN) All M16 to M100 1/2" to 4"

316 Stainless Steel (EX-SLN)

Nylon (EX-NLN)

Steel (EX-MLN)

316 Stainless Steel

Nylon

Industrial

M16 to M100

M20 to M63

M20 to M50

Earth Tags

provide an earth bond connection for an entry component

Brass (EX-BET) All M16 to M100

1/2" to 4"

-

-

1/2" to 4"

THREAD TYPES

BSP

1/2" to 4"

1/2" to 4"

-

-

1/2" to 4"

FRENCH

F48

F48

-

-

F48

IP Sealing Washer

s are fitted between an entry component and the equipment to maintain the IP rating of the equipment

Nylon (EX-NSW)

Red Fibre (EX-SFW)

All

All

M16 to M100

M20 to M75

1/2" to 4"

-

1/2" to 4"

-

Serrated Star Washers

can be used in conjunction with a locknut to provide additional fixing security and improve bonding

316 Stainless Steel (EX-SSW) All M16 to M100 1/2" to 4" 1/2" to 4"

F48

-

F48

Galvanised Steel (EX-GSW) All M20 to M75

Shrouds

can be used to protect the gland from the surrounding environment

PVC (EX-PVC)

PCP (EX-PCP)

LSOH (EX-LSH)

-

16 to 100

16 to 85 Shrouds are not available for all glands, please see specific gland page for exact details

16 to 85

NOTES:

• As standard ISO Metric threads are supplied with a 1.5mm pitch up to and including M75 and a 2.0mm pitch for sizes above M75

52

Thread Types

ISO

METRIC

IEC 60423

1993

NPT

ANSI

B1.20.1

1983

NPS

ANSI

B1.20.1

1983

ISO Pipe

Parallel

ISO R/7;

BS2779

(BSPP, G,

R, PF)

ISO Pipe

Taper to

ISO R/7;

BS21

(BSPT, GK)

Thread Ref

S10

F48

P1

P2

P3

P4

P5

P6

S7

S8

S9

S4

S5

S6

T3

T4

T5

P7

T1

T2

T6

T7

N8

N9

N10

S1

S2

S3

M100

N1

N2

N3

N4

N5

N6

N7

M50

M63

M75

M80

M85

M90

M16

M20

M25

M32

M40

Entry Thread Reference Tables

Size

11/4"

11/2"

2"

21/2"

3"

31/2"

4"

PG48 (FR)

1/2"

3/4"

1”

11/4"

11/2"

2"

21/2"

1/2"

3/4"

1"

11/4"

11/2"

2"

21/2"

100 x 2.0

1/2"

3/4"

1"

11/4"

11/2"

2”

21/2"

3”

31/2"

4"

1/2"

3/4"

1"

16 x 1.5

20 x 1.5

25 x 1.5

32 x 1.5

40 x 1.5

50 x 1.5

63 x 1.5

75 x 1.5

80 x 2.0

85 x 2.0

90 x 2.0

Major Ø

41.61

47.67

59.72

72.16

88.06

100.78

113.43

59.61

20.96

26.44

33.25

41.91

47.80

5961

75.18

20.96

26.44

33.25

41.91

47.80

5961

75.18

99.97

21.22

26.57

33.23

41.99

48.05

60.09

72.70

88.61

101.36

113.97

20.90

26.26

32.84

15.97

19.97

24.97

31.97

39.97

49.97

62.97

74.97

19.97

84.97

89.97

TPI

8.00

11.00

14.0

14.0

11.0

11.0

11.0

11.0

11.50

11.50

11.50

8.00

8.00

8.00

11.0

14.0

14.0

11.0

11.0

11.0

11.0

11.0

8.00

8.00

8.00

14.00

14.00

11.50

12.70

14.00

14.00

11.50

11.50

11.50

11.50

8.00

16.93

16.93

16.93

16.93

16.93

16.93

16.93

16.93

12.70

12.70

12.70

Pitch

3.18

2.31

1.81

1.81

2.31

2.31

2.31

2.31

2.20

2.20

2.20

3.18

3.18

3.18

2.31

1.81

1.81

2.31

2.31

2.31

2.31

2.31

3.18

3.18

3.18

1.81

1.81

2.20

2.00

1.81

1.81

2.20

2.20

2.20

2.20

3.18

1.50

1.50

1.50

2.00

2.00

2.00

1.50

1.50

1.50

1.50

1.50

Thread Length Min Hex A/C

44.0

26.9

19.9

20.1

25.0

25.6

26.0

26.9

25.6

26.0

26.9

39.9

41.5

42.8

39.9

19.9

20.1

25.0

25.6

26.0

26.9

39.9

41.5

42.8

44.0

19.9

20.1

21.5

25.0

19.9

20.1

21.5

25.6

26.0

26.9

39.9

16.0

19.0

19.0

25.0

25.0

25.0

16.0

16.0

16.0

16.0

16.0

125.7

71.5

26.5

33.0

41.4

50.6

60.5

71.5

50.6

60.5

71.5

88.0

99.0

115.2

88.0

26.5

33.0

41.4

50.6

60.5

71.5

88.0

99.0

115.2

125.7

26.5

33.0

41.4

125.7

26.5

33.0

41.4

50.6

60.5

71.5

88.0

26.5

33.0

41.4

50.6

60.4

71.5

88.0

99.0

115.2

115.2

125.7

53

Ingress Protection

It is essential when selecting cable glands and/or accessories to ensure that the products will maintain the IP rating of the equipment and the integrity of the installation.

IP Codes are based on the IEC Standard 529, degrees of protection provided by enclosures.

In most cases Peppers cable glands will maintain Ingress Protection of the equipment into which they are installed to:

IP 66

• Dust Tight. No ingress of dust possible.

• Protected against heavy seas or powerful jets of water

IP67

• Dust Tight. No ingress of dust possible

• Protected against harmful ingress of water when immersed between a depth of 150mm to 1m

IP68

• Dust Tight. No ingress of dust possible.

• Protected against submersion. Suitable for continuous immersion in water at stated depth.

• Depth stated for Amphenol cable glands is 25m

DTS 01 (Deluge)

• This test was originally constructed by shell and Esso in the UK to simulate the routine deluging of electrical equipment on offshore installations.

IP 54- Minimum requirement for Hazardous Location products

• Dust protected. Prevents ingress of dust sufficient to cause harm.

• Protected from splashing water from any direction

As a general guide to selecting the sealing method that is most likely to maintain the required IP rating for different entry types, we recommend:

Clearance Holes

- Integral ‘O’ ring seal or nylon IP washer

Parallel Threaded Entries

- Integral ‘O’ ring seal, IP washer or non-hardening thread sealant

Taper Threaded Entries

- Non-hardening thread sealant

Gland Weight Data

Gland Size Entry

Thread

Cable Gland Type

63s

63

75s

75

80

85

90

100

16

20s

20

25

32

40

50s

50

M63

M63

M75

M75

M80

M85

M90

M100

M20

M20

M20

M25

M32

M40

M50

M50

2345

2005

1980

2200

3970

3300

4314

3537

EX-20

164

160

250

400

750

1095

1415

1295

1410

1140

1745

1375

3255

2655

3559

2795

EX-25

144

130

186

262

420

672

980

758

EE-30

134

124

180

262

402

680

1040

764

EX-35

84

90

94

152

176

332

570

458

EX-40

142

144

158

256

298

556

980

796

EE-RG

6

-

8

16

28

35

-

65

1410

1185

1730

1495

3130

850

684

954

764

1430

1410

1170

1565

1310

2130 -

-

-

74

-

2500

3280

1290

1510

1980

2360 -

4065

5215

3054 1485 2285 -

All weights are approximate and shown in grams

4410

2100

2025

2330

2240

4985

EX-60

165

165

240

400

725

1060

1435

1340

NOTES:

• Weights shown are for Brass versions (except Nylon EE-RG)

• To estimate weights for 316 Stainless Steel versions apply a factor of 0.92

Weights for glands with non-metric entry threads will vary

• Approximate weights for EX-45, EX-50, EX-55 are available on application

Approximate weights for CGDS, CGSS and CGU industrial glands are the same as for EX versions

-

1040

-

1150

2730

2255

2790

2450

EX-65

-

115

170

260

384

585

-

700

54

-

1355

-

1475

3415

2830

3985

3580

EX-75

-

-

215

340

485

730

-

875

1555

1695

1750

1880

3860

3250

3985

3580

EX-70

-

180

260

385

570

885

1035

1160

-

910

-

1070

1770

-

-

-

CGA

-

52

84

140

180

436

-

480

Amphenol

®

/Pyle

®

Industrial Cord Grips

Amphenol

®

/Pyle

®

Industrial Cord Grips make sure your cord or cable stays in and everything else stays out. This product is designed for liquid-tight strain relief of cord, cable, and flexible conduit. Available in straight, 45°, and 90° styles, Amphenol

®

/Pyle

® cord grips are UL listed, and CSA certified.

This section will provide information on a large family of cable pass-thru and strain relief devices for use with industrial connectors by showing complete assemblies as well as component parts. Contact your Amphenol

®

/Pyle

® distributor for assistance.

Features & Benefits

UL Listed and CSA certified.

Used for sealing where moving parts or handling can abuse connections.

Tapered rubber grommet and seat.

Secure cord the entire length of grommet making a liquid-tight seal.

Variety of styles: straight, 45°, 90°, and flexible.

Assures ease of installation and permits custom cable routing

Various strain relief options:

Standard compression nut, mechanical clamp nut or basket weave styles.

Tapered conduit threads.

Provide strong water and oil-tight joint.

Machined components.

Strong, lightweight, and have long service life.

Male and female threads.

Provides versatility in panelboard or threaded hub applications

Applications

FOR POWER CONTROL:

• Switchboards

• Machine Tools

• Heating and Cooling

• Lighting and Ballasts

• Portable Equipment

• Motors and Generators

• Production Machinery

• Processing Equipment

• Robotics and Welding

• Standby Power

• Medical/Dental Equipment

FOR COMMUNICATION:

• Radio and Radar

• Television

• Transformers

• Data Processing

• Instruments

FOR TRANSPORATION

• Shipyards

• Refrigerated Containers

• Railroad and Trucking

Materials and Finishes

Straight Bodies

45° & 90° Bodies

Grommets

Washers

Compression Nuts

Mechanical Nuts

Copper-free aluminum bar stock

Cadmium plated ferrous alloy

Oil-resistant synthetic rubber

Cadmium plated cold rolled steel

Copper-free aluminum bar stock

Cast Aluminum

55

Allowable Ampacities

of Insulated Conductors as taken from 1987 Edition of National Electric Code.

Rated 0-2000 Volts, 60° to 90°

Not More Than Three Conductors in Raceway or Cable or Earth

(Directly Buried), Based on Ambient Temperature of 30°C(86°F)

Size

AWG

MCM

10

8

6

4

18

16

14

12

1

0

3

2

30

40

55

70

. . .

. . .

20

25

85

95

110

125

Temperature Rating of Conductors (Copper)

60°C

(140°F)

75°C

(176°F)

†TW, †UF †FEPW, †RH,

†RHW, †THW,

†THWN,†XHHW,

†USE, †ZW

85°C

(185°F)

V

90°C

(194°F)

TA, TBS, SA,

AVB, SIS, †FEP,

†FEPB, †RHH,

†THHN

†XHHW*

50

65

85

100

. . .

. . .

20

25

35

115

130

150

40

55

70

95

. . .

18

25

30

110

125

145

165

55

75

95

110

14

18

25

30

40

130

150

170

Ampacity Correction Factors

For ambient temperatures other than 30°C, multiply the ampacities shown above by the appropriate factor shown below.

Ambient

Temp. °C (°F)

60°C

(140°F)

75°C

(176°F)

85°C

(185°F)

90°C

(194°F)

31-40 (87-104)

41-45 (105-113)

46-50 (114-122)

51-60 (123-141)

61-70 (142-158)

71-80 (159-176)

.82

.71

.58

. . .

. . .

. . .

.88

.82

.75

.58

.35

. . .

.90

.85

.80

.67

.52

.30

†The overcurrent protection for conductor types marked with an obelisk (†) shall not exceed 15 amperes for 14AWG and 30 amperes for 10 AWG copper.

*For dry locations only. See 75°C column for wet locations

.91

.87

.82

.71

.58

.41

56

Fraction Conversion Table

Fraction

1/64

1/32

3/64

1/16

5/64

3/32

7/64

1/8

9/64

5/32

11/64

3/16

13/64

7/32

15/64

1/4

25/64

13/32

27/64

7/16

29/64

15/32

31/64

1/2

17/64

9/32

19/64

5/16

21/64

11/32

23/64

3/8

0.1406

0.1562

0.1719

0.1875

0.2031

0.2188

0.2344

0.2500

Decimal Mm

0.0156

0.0312

0.0469

0.0625

0.0781

0.0938

0.1094

0.1250

0.379

0.794

1.191

1.588

1.984

2.381

2.778

3.175

3.572

3.969

4.366

4.762

5.159

5.556

5.953

6.350

0.2656

0.2812

0.2969

0.3125

0.3281

0.3438

0.3594

0.3750

0.3906

9.922

0.4062

10.319

0.4219

10.716

0.4375

11.112

0.4531

11.509

0.4688

11.906

0.4844

12.303

0.5000

12.700

6.747

7.144

7.541

7.938

8.334

8.731

9.128

9.525

Fraction

33/64

17/32

35/64

9/16

37.64

19/32

39/64

5/8

41/64

21/32

43/64

11/16

45/64

23/32

47/64

3/4

57/64

29/32

59/64

15/16

61/64

31/32

63/64

1

49/64

26/32

51/64

13/16

53/64

27/32

55/64

7/8

Decimal Mm

0.5156

13.097

0.5312

13.494

0.5469

13.891

0.5625

14.288

0.5781

14.684

0.5938

15.081

0.6094

15.478

0.6250

15.875

0.6406

16.272

0.6562

16.669

0.6719

17.066

0.6875

17.462

0.7031

17.859

0.7188

18.256

0.7344

18.653

.7500

19.050

0.7655

19.447

0.7812

19.844

0.7969

20.241

0.8125

20.638

0.8281

21.034

0.8438

21.431

0.8594

21.828

0.8750

22.225

0.8906

22.622

0.9062

23.019

0.9219

23.416

0.9375

23.812

0.9531

24.209

0.9688

24.606

0.9844

25.003

1.0000

25.400

Amphenol Cord Grips

Cord Grip Specifications

Selected Cord and Cable Diameters

Type of Cord

SJ, SJO

S, SO, ST, STO

W

Bus Drop Cable

1

1/0

2/0

3/0

4/0

250

3

2

6

4

18

16

14

12

10

8

18

16

14

14

12

10

8

AWG

Size of

Conductors

Number of Conductors and

Approximate O.D. in Inches

2

.300

.330

.375

3

.330

.360

.395

4

.360

.390

.420

.385

.400

.530

.600

.400

.425

.560

.635

.430

.480

.605

.665

.640

.690

.745

.820-.930

.885-1.010

.975-1.100

.700-.840

1.080

1.170

1.270

1.440

1.520

1.650

1.770

1.920

2.160

.750-.910

.820-.990

1.170

1.270

1.240

1.340

1.510

1.650

1.750

1.890

2.070

2.390

1.340

1.480

1.680

1.790

1.930

2.070

2.260

.410

.450

.530

.670

NOTE: Dimensions are approximate. When possible consult manufacturer’s data.

Amperages of Electric Motors

20

25

30

40

5

10

15

50

60

75

1

2

3

1/4

1/3

1/2

3/4

Motor

Horse

Power 200 V.

1/20

1/12

1/8

1/6

0.39

0.55

0.74

0.90

1.22

1.52

2.07

2.88

3.68

5.18

6.67

9.66

15.4

22.6

29.7

43.6

57.4

70.9

84.3

111.

137.

163.

201.

13.4

19.6

25.8

38.0

49.9

61.7

73.3

96.4

1.06

1.32

1.80

2.50

3.20

4.50

5.80

8.40

Motor Full Load Current (Amps)

Three Phase Single Phase

230V.

460V 575V.

115V.

230V.

0.34

0.48

0.64

0.78

0.17

0.24

0.32

0.39

0.14

0.19

0.26

0.31

1.30

1.90

2.60

3.24

0.65

0.95

1.30

1.62

0.53

0.66

0.90

1.25

1.60

2.25

2.90

4.20

0.42

0.53

0.72

1.00

1.28

1.80

2.32

3.36

4.40

5.47

7.45

10.1

126

17.2

21.4

29.1

119.

142.

175.

6.68

9.82

12.9

19.0

24.9

30.8

36.7

48.2

59.6

70.8

87.6

5.35

7.86

10.3

15.2

20.0

24.7

29.3

38.5

47.6

56.6

70.0

NOTE: These are approximate currents to be used for selecting cord wire sizes.

42.9

58.4

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

21.4

29.2

36.3

49.4

. . .

. . .

. . .

2.20

2.74

3.73

5.07

6.31

8.59

10.7

14.5

57

DB/DBM GROUP

Strain-relief connectors for flexible cord and cable small straight body, male thread

Aluminum body and compression nut with washer and single hole oil-resistant grommet

UL

®

LISTED

File No. E53509

CERTIFIED

File No. LR-64107

This small body connector is ideal for internal uses, as well as conduit hub and panel-board mounting into threaded bodies or with locknuts. Complete units listed require no other parts excecpt cable. Component parts allow expansion or updating of present equipment.

Suitable for use in hazardous locations per National Electric

Code Class I, Div. 2; Class II, Div. 1

& 2; Class III, Div. 1&2.

Insulated throat option:

Add suffix “T” to all complete assembly part numbers on this page. E.g.: DB-9916T.

1

3

CONDUIT

H U B

SIZE

3

1

/

/

4

/

8

/

2

1”

4

9

11

7

1

1

/

PANEL

HOLE

SIZE

16

/

8

1

3

/

16

/

/

8

8

CORD

DIAMETER

RANGE IN (MM)

.125-.250 (3.17-6.35)

.187-.312 (4.75-7.92)

.250-.375 (6.35-9.52)

.312-.437 (7.92-11.1)

.375-.500 (9.52-12.7)

.437-.562 (11.1-14.3)

.500-.625 (12.7-15.9)

.625-.687 (15.9-17.4)

.687-.750 (17.4-19.1)

*.750-.875 (19.1-22.2)

*.875-1.00 (22.2-25.4)

.375-.437 (9.52-11.1)

.437-.500 (11.1-12.7)

.500-.562 (12.7-14.3)

.562-.625 (14.3-15.9)

.625-.687 (15.9-17.4)

.687-.750 (17.4-19.1)

.687-.812 (17.4-20.6)

.750-.875 (19.1-22.2)

.812-.937 (20.6-23.8)

*.875-1.00 (22.2-25.4)

.125-.187 (3.17-4.75)

.187-.250 (4.75-6.35)

.250-.312 (6.35-7.92)

.125-.187 (3.17-4.75)

.187-.250 (4.75-6.35)

.250-.312 (6.35-7.92)

.312-.375 (7.92-9.52)

.375-.437 (9.52-11.1)

.125-.187 (3.17-4.75)

.187-.250 (4.75-6.35)

.250-.312 (6.35-7.92)

.312-.375 (7.92-9.52)

.375-.437 (9.52-11.1)

.125-.250 (3.17-6.35)

.187-.312 (4.75-7.92)

.250-.375 (6.35-9.52)

.312-.437 (7.92-11.1)

.375-.500 (9-52-12.7)

*.437-.562 (11.1-14.3)

*.500-.625 (12.7-15.9)

*.625-.687 (15.9-17.4)

*.687-.750 (17.4-19.1)

COMPLETE ASSEMBLY PART NUMBERS

WITH WITH WITH

COMPRESSION NUT MECHANICAL NUT WOVEN GRIP

DBM-2204-M

DBM-2205

DBM-2206-M

DBM-2207-M

DBM-2208-M

DBM-2209-M

DBM-2210-M

DBM-2311-M

DB-2312-M

DBM-2514-M

DBM-2516-M

DBM-3307-M

DBM-3308-M

DBM-3309-M

DBM-3310-M

DBM-3311-M

DBM-3312-M

DBM-3513-M

DBM-3514-M

DBM-3515-M

DBM-3516-M

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DBM-1204-M

DBM-1205-M

DBM-1206-M

DBM-1207-M

DBM-1208-M

DBM-1209-M

DBM-1210-M

DBM-1311-M

DBM-1312-M

DB-614

DB-6516

DB-638

DB-6716

DB-612

DB-6919

DB-6

DB-111116

DB-11

DB-2514

DB-2516

DB-33716

DB-3312

DB-33916

DB-3358

DB-331116

DB-33

DB-1413

DB-1478

DB-141516

DB-14

DB-44316

DB-4414

DB-44516

DB-4316

DB-414

DB-4516

DB-438

DB-4

DB-3316

DB-314

DB-3516

DB-338

DB-3

DB-7

DB-9516

DB-8

DB-9716

DB-9

DB-9916

DB-10

DB-91116

DB-934

. . . . .

DBKM-2205

DBKM-2206

DBKM-2207

DBKM-2208

DBKM-2209

DBKM-2210

DBKM-2311

DBKM-2312

DBKM-2514

DBKM-2516

DBKM-3307

DBKM-3308

DBKM-3309

DBKM-3310

DBKM-3311

DBKM-3312

DBKM-3513

DBKM-3514

DBKM-2515

DBKM-3516

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DBKM-1205

DBKM-1206

DBKM-1207

DBKM-1208

DBKM-1209

DBKM-1210

DBKM-1311

DBKM-1312

*Maximum cord size will not pass through body without removing outer jacket.

Other grommets both single and multi-hole are available–see page 70.

See pages 60-61 for dimensional information.

58

FORM BODY

SIZE BORE--IN (MM)

1

DB-4-G

.35 (8.9)

1

1

2

3

2

3

5

3

5

DB-4-A

.44 (11.2)

DB-3-A

.44 ( 11.2

DB-9-A

.64 (16.3

DB-934-A

.62 (15.7)

DB-6-A

.64 (16.3)

DB-11-A

.75 (19.1)

DB-25-M

.81 (20.6)

DB-33-A

.75 (19.1)

DB-14-A

1.03 (26.2)

GROMMET

DB-9-F

DB-9-V

DB-9-E

DB-9-J

DB-9-D

DB-9-V

DB-9-C

DB-11-O

DB-11-C

DB-14-H

DB-14-C

DB-11-E

DB-11-D

DB-11-R

DB-11-K

DB-11-O

DB-11-C

DB-14-K

DB-14-H

DB-14-L

DB-14-C

DB-4-F

DB-4-J

DB-4-D

DB-4-F

DB-4-J

DB-4-D

DB-4-E

DB-4-C

DB-4-F

DB-4-J

DB-4-D

DB-4-E

DB-4-C

DB-9-F

DB-9-V

DB-9-E

DB-9-J

DB-9-D

DB-9-U

DB-9-C

DB-11-O

DB-11-C

PLAIN

WASHER

PX-4-CS

PX-4-CS

PX-4-CS

PX-8-CS

PX-11-CS

PX-8-B

PX-11-CS

PX-14-CS

PX-11-CS

PX-14-CS

COMPONENT PART NUMBERS

COMPRESSION MECHANICAL

NUT NUT

DB-4-B

DB-4-B

DB-4-B

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DB-9-B

DB-11-B

DB-9-B

DB-11-B

DB-14-B

DB-11-B

DB-14-B

PX-10

PX-11

PX-10

PX-11

PX-14

PX-11

PX-14

WOVEN

GRIP

WOVEN GRIP WOVEN GRIP

WASHER NUT

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DBKG-5

DBKG-6

DBKG-8

DBKG-8

DBKG-10

DBKG-10 PX-8-CS

DBKG12 PX-11-CS

DBKG-12 PX-11-CS

DBK-9-B

DBK-11-B

DBK-11-B

. . . . .

. . . . .

DBKG-5

DBKG-6

DBKG-8

DBKG-8

DBKG-10

DBKG-10 PX-8-CS

DBKG-12 PX-11-CS

DBKG-12

DBKG-14

DBKG-16 PX-14-CS

DBK-9-B

DBK-11-B

DBK-14-B

DBKG-8

DBKG-8

DBK-11-W

DBK-11-W

DBKG-10 DBK-11-W

DBKG-10 DBK-11-W

DBKG-12 PX-11-CS

DBKG-12 PX-11-CS

DBKG-14

DBKG-14

DBKG-16 PX-14-CS

DBKG-16 PX-14-CS

DBK-11-B

DBK-14-B

Not required

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

59

DBZM GROUP

Strain relief connectors for flexible cord and cable

Large straight body, male thread

Aluminum body and compression nut with washer and single hole oil-resistant grommet

LISTED

File No. E3509

CERTIFIED

File No. LR-64107

Large body DBZ connectors can be employed in retrofit or new installations. Versatility allows use in panelboards and in threaded hubs. Component parts are available separately.

Suitable for use in hazardous locations per National Electric

Code Class I, Div. 2; Class II, Div. 1

& 2; Class III, Div. 1&2.

CONDUIT

H U B

SIZE

1

1

/

4

” 1

PANEL

HOLE

SIZE

3

/

4

1

2”

2

3”

1

1

/

/

2

2

” 2”

2

3”

3

1

5

/

/

2

8

CORD

DIAMETER

RANGE IN (MM)

.750- .875 (19.1-22.2)

.875-1.000 (22.2-25.4)

1.000-1.125 (25.4-28.6)

1.125-1.250 (28.6-31.8)

*1.250-1.375 (31.8-34.9)

.750- .875 (19.1-22.2)

.875-1.000 (22.2-25.4)

1.000-1.125 (25.4-28.6)

1.125-1.250 (28.6-31.8)

1.250-1.375 (31.8-34.9)

1.375-1.500 (34.9-38.1)

*1.500-1.625 (38.1-41.3)

*1.625-1.750 (41.3-44.5)

*1.750-1.875 (44.5-47.6)

1.250-1.375 (31.8-34.9)

1.375-1.500 (34.9-38.1)

1.500-1.625 (38.1-41.3)

1.625-1.750 (41.3-44.5)

1.750-1.875 (44.5-47.6)

COMPLETE ASSEMBLY PART NUMBERS

WITH WITH WITH

COMPRESSION NUT MECHANICAL NUT WOVEN GRIP

DBZM-4714

DBZM-4716

DBZM-4718

DBZM-4720

DBZM-4722

DBZM-5714

DBZM-5716

DBZM-5718

DBZM-5720

DBZM-5722

DBZM-5824

DBZM-5826

DBZM-5828

DBZM-5830

DBZM-6822

DBZM-6824

DBZM-6826

DBZM-6828

DBZM-6830

DBZM-4714-M

DBZM-4716-M

DBZM-4718-M

DBZM-4720-M

DBZM-4722-M

DBZM-5714-M

DBZM-5716-M

DBZM-5718-M

DBZM-5720-M

DBZM-5722-M

DBZM-5824-M

DBZM-5826-M

DBZM-5828-M

DBZM-5830-M

DBZM-6822-M

DBZM-6824-M

DBZM-6826-M

DBZM-6828-M

DBZM-6830-M

1.875-2.000 (47.6-50.8)

2.000-2.125 (50.8-54.0)

2.125-2.250 (54.0-57.2)

2.250-2.375 (57.2-60.3)

DBZM-7932

DBZM-7934

DBZM-7936

DBZM-7938

DBZM-7932-M

DBZM-7934-M

DBZM-7936-M

DBZM-7938-M

1.875-2.000 (47.6-50.8)

2.000-2.125 (50.8-54.0)

2.125-2.250 (54.0-57.2)

2.250-2.375 (57.2-60.3)

DBZM-8932

DBZM-8934

DBZM-8936

DBZM-8938

DBZM-8932-M

DBZM-8934-M

DBZM-8936-M

DBZM-8938-M

*Maximum cord size will not pass through body without removing outer jacket.

Other grommets both single and multi-hole are available–see page 70.

DBZM-7932-K

DBZM-7934-K

DBZM-7936-K

DBZM-7938-K

DBZM-8932-K

DBZM-8934-K

DBZM-8936-K

DBZM-8938-K

DBZM-4714-K

DBZM-4716-K

DBZM-4718-K

DBZM-4720-K

DBZM-4722-K

DBZM-5714-K

DBZM-5716-K

DBZM-5718-K

DBZM-5720-K

DBZM-5722-K

DBZM-5824-K

DBZM-5826-K

DBZM-5828-K

DBZM-5830-K

DBZM-6822-K

DBZM-6824-K

DBZM-6826-K

DBZM-6824-K

DBZM-6830-K

E

MAX

A

B*

D*

DB/DBM, FORMS 1, 2, 3, 5

C

60

FORM BODY

SIZE BORE–IN (MM)

7-Z DBZ-47-M

1.31 (33.2)

7-Z

8-Z

8-Z

9-Z

9-Z

DBZ-57-M

1.44 (36.6)

DBZ-58-M

1.56 (39.7)

DBZ-68-M

1.94 (49.2)

DBZ-79-M

2.44 (62.0)

DBZ-89-M

2.44 (62.0)

PLAIN

WASHER

DBZ-716-W

DBZ-716-W

DBZ-720-W

DBZ-720-W

DBZ-723-W

DBZ-716-W

DBZ-716-W

DBZ-720-W

DBZ-720-W

DBZ-723-W

DBZ-824-W

DBZ-826-W

DBZ-828-W

DBZ-831-W

DBZ-824-W

DBZ-824-W

DBZ-828-W

DBZ-828-W

DBZ-831-W

DBZ-932-W

DBZ-936-W

DBZ-936-W

DBZ-939-W

DBZ-932-W

DBZ-936-W

DBZ-936-W

DBZ-939-W

GROMMET

DBZ-714

DBZ-716

DBZ-718

DBZ-720

DBZ-722

DBZ-714

DBZ-716

DBZ-718

DBZ-720

DBZ-722

DBZ-824

DBZ-826

DBZ-828

DBZ-830

DBZ-822

DBZ-824

DBZ-826

DBZ-828

DBZ-830

DBZ-932

DBZ-934

DBZ-936

DBZ-938

DBZ-932

DBZ-934

DBZ-936

DBZ-938

COMPONENT PART NUMBERS

COMPRESSION

NUT

MECHANICAL

NUT

DBZ-7-B

DBZ-7-B

DBZ-8-B

DBZ-8-B

DBZ-9-B

DBZ-9-B

DBZ-7-B

DBZ-7-M

DBZ-8-M

DBZ-8-M

DBZ-9-M

DBZ-9-M

WOVEN

GRIP

WOVEN GRIP WOVEN GRIP

WASHER NUT

DBKG-14 LZW-9316-16A

DBKG-16 LZW-9316-16A

DBKG-18 LZW-9316-20A DBZ-7-B

DBKG-20 LZW-9316-20A

DBKG-22

DBKG-14 LZW-9316-16A

DBKG-16 LZW-9316-16A

DBKG-18 LZW-9316-20A DBZ-7-B

DBKG-20 LZW-9316-20A

DBKG-22

DBKG-26

DBKG-26

DBKG-28

DBKG-28

DBZ-8-B

DBKG-22 LZW-9320-22A

DBKG-26

DBKG-26

DBKG-28

DBKG-28

DBKG-34

DBKG-34

DKGZ-38

DBKG-38

DBKG-34

DBKG-34

DBKG-38

DBKG-38

Not required

DBZ-8-B

DBZ-9-B

DBZ-9-B

E Max

DIMENSIONS

A

B *

C

D *

ACROSS

FLATS

E MAX

*With nut snug, grommet not compressed.

FORM SIZE

1 2 3 5 7-Z 8-Z 9-Z

.88

1.13

1.25

1.63

2.23

2.53

3.28

1.53

1.84

2.06

2.69

3.22

3.22

3.91

1.38

2.49

1.66

1.38

2.69

1.66

1.75

3.50

2.069

2.00

4.02

2.78

2.50

4.43

3.46

3.00

4.88

4.10

A

C

D*

B*

DBZ, FORMS 7-Z, 8-Z, 9-Z

61

DBL/DBZL GROUP

Strain-relief connectors for flexible cord and cable

90° elbow body, male thread

Ferrous alloy body, aluminum compression nut with washer and single hole oil-resistant grommet

UL

®

LISTED

File No. E53509

CERTIFIED

File No. LR-64107

These 90° connectors allow the installation of cord and cable even in tight quarters. Rugged ferrous alloy body and aluminum compression nut assure long life in abusive situations.

Suitable for use in hazardous locations per National Electric

Code Class I, Div. 2; Class II, Div. 1

& 2; Class III, Div. 1&2.

CONDUIT

H U B

SIZE

1 /

2

” 7 /

8

PANEL

HOLE

SIZE

Insulated throat option:

Add suffix “T” to complete assembly part numbers for ½”-1” only.

E.g.:DBL-3514-MT.

3

1

1

/

4

” 1

1”

1

2”

1

/

/

4

2

1

1

2”

2

1

3

3

1

/

/

/

/

8

8

4

2

CORD

DIAMETER

RANGE IN (MM)

.125-.250 (3.17-6.35)

.187-.312 (4.75-7.92)

.250-.375 (6.35-9.52)

.312-.437 (7.92-11.1)

.375-.500 (9.52-12.7)

* .437-.562 (11.1-14.3)

* .500-.625 (12.7-15.9)

.312-.375 (7.92-9.52)

.375-.437 (9.52-11.1)

.437-.500 (11.1-12.7)

.500-.562 (12.7-14.3)

.562-.625 (14.3-15.9)

.625-.687 (15.9-17.4)

* .687-.750 (17.4-19.1)

.687-.812 (17.4-20.6)

.750-.875 (19.1-22.2)

.812-.937 (20.6-23.8)

* .875-1.000 (22.2-25.4)

.750-.875 (19.1-22.2)

.875-1.000 (22.2-25.4)

1.000-1.125 (25.4-28.6)

1.125-1.250 (28.6-31.8)

*1.250-1.375 (31.8-34.9)

*1.375-1.500 (34.9-38.1)

*1.500-1.625 (38.1-41.3)

*1.625-1.750 (41.3-44.5)

*1.750-1.875 (44.5-47.6)

*1.375-1.500 (34.9-38.1)

*1.500-1.625 (38.1-14.3)

*1.625-1.875 (44.5-47.6)

*1.750-1.875 (44.5-47.6)

COMPLETE ASSEMBLY PART NUMBERS

WITH WITH WITH

COMPRESSION NUT MECHANICAL NUT WOVEN GRIP

DB-790

DB-9590

DB-890

DB-9790

DB-990

DB-9990

DB-1090

DB-113890

DB-1171690

DB-111290

DB-1191690

DB-115890

DB-11111690

DB-1190

DB-141390

DB-147890

DB-14151690

DB-1490

DBZL-4714

DBZL-4716

DBZL-4718

DBZL-4720

DBZL-4722

DBZL-5824

DBZL-5826

DBZL-5828

DBZL-5830

DBZL-6824

DBZL-6826

DBZL-6828

DBZL-6830

DBL-1204-M

DBL-1205-M

DBL-1206-M

DBL-1207-M

DBL-1208-M

DBL-1209-M

DBL-1210-M

DBL-2306-M

DBL-2307-M

DBL-2308-M

DBL-2309-M

DBL-2310-M

DBL-2311-M

DBL-2312-M

DBL-3513-M

DBL-3514-M

DBL-3515-M

DBL-3516-M

DBZL-4714-M

DBZL-4716-M

DBZL-4718-M

DBZL-4720-M

DBZL-4722-M

DBZL-5824-M

DBZL-5826-M

DBZL-5828-M

DBZL-5830-M

DBZL-6824-M

DBZL-6826-M

DBZL-6828-M

DBZL-6830-M

. . . . .

DBKL-1205

DBKL-1206

DBKL-1207

DBKL-1208

DBKL-1209

DBKL-1210

DBKL-2306

DBKL-2307

DBKL-2308

DBKL-2309

DBKL-2310

DBKL-2311

DBKL-2312

DBKL-3513

DBKL-3514

DBKL-3515

DBKL-3516

DBZL-4714-K

DBZL-4716-K

DBZL-4718-K

DBZL-4720-K

DBZL-4722-K

DBZL-5824-K

DBZL-5826-K

DBZL-5828-K

DBZL-5830-K

DBZL-6824-K

DBZL-6826-K

DBZL-6828-K

DBZL-6830-K

*Maximum cord size will not pass through body without removing outer jacket.

Other grommets both single and multi-hole are available–see page 70.

DBL, FORMS 2, 3, 5 DBLZ, FORMS 7-Z, 8-Z

E†

B†

B†

F

D

C

C

D

A

A

62

FORM BODY

SIZE BORE–IN (MM)

2

3

5

7-Z

8-Z

8-Z

DB-990-A

.56 (14.3)

DB-1190-A

.75 (19.1)

DB-1490-A

1.03 (26.2)

DBZ-47-L

1.25 (31.8)

DBZ-58-L

1.44 (36.6)

DBZ-68-L

1.88 (47.7)

E†

GROMMET

DB-9-F

DB-9-V

DB-9-E

DB-9-J

DB-9-D

DB-9-U

DB-9-C

DB-11-V

DB-11-E

DB-11-D

DB-11-R

DB-11-K

DB-11-O

DB-11-C

DB-14K

DB-14-H

DB-14-L

DB-14-C

DBZ-714

DBZ-716

DBZ-718

DBZ-720

DBZ-722

DBZ-824

DBZ-826

DBZ-828

DBZ-830

DBZ-824

DBZ-826

DBZ-828

DBZ-830

PLAIN

WASHER

PX-8-CS

PX-11-CS

PX-14-CS

DBZ-716-W

DBZ-716-W

DBZ-720-W

DBZ-720-W

DBZ-723-W

DBZ-824-W

DBZ-828-W

DBZ-828-W

DBZ-831-W

DBZ-824-W

DBZ-828-W

DBZ-828-W

DBZ-831-W

F

COMPONENT PART NUMBERS

COMPRESSION

NUT

MECHANICAL

NUT

DB-9-B

DB-11-B

DB-14-B

DBZ-7-B

DBZ-8-B

DBZ-8-B

PX-10

PX-11

PX-14

DBZ-7-M

DBZ-8-M

DBZ-8-M

WOVEN

GRIP

WOVEN GRIP WOVEN GRIP

WASHER NUT

. . . . .

. . . . .

DBKG-5

DBKG-6

DBKG-8

DBKG-8

DBKG-10

DBKG-10 PX-8-CS

DBK-9-B

DBKG-6

DBKG-8

DBK-11-W

DBK-11-W

DBKG-8 DBK-11-W

DBKG-10 DBK-11-W

DBKG-10 DBK-11-W

DBKG-12 PX-11-C

DBKG-12 PX-11-C

DBKG-14

DBKG-14

DBKG-16 PX-14-CS

DBKG-16 PX-14-CS

DBK-11-B

DBK-14-B

DBKG-14 LZW-9316-16A

DBKG-16 LZW-9316-16A

DBKG-18 LZW-9316-20A DBZ-7-B

DBKG-20 LZW-9316-20A

DBKG-22

DBKG-26

DBKG-26

DBKG-28

DBKG-28

DBKG-26

DBKG-26

DBKG-28

DBKG-28

DBZ-8-B

DBZ-8-B

Not required

DIMENSIONS

A

B †

C

D

E †

ACROSS

FLATS

F MAX

2

1.13

1.88

1.44

1.38

2.53

1.66

3

1.25

1.86

1.56

1.38

2.51

1.66

FORM SIZE

5

1.63

2.94

2.00

1.75

3.75

2.06

† With nut snug, grommet not compressed.

7-Z

2.23

3.28

2.38

2.00

4.12

2.78

8-Z

2.53

3.78

2.88

2.50

4.69

3.46

63

DBA GROUP

Strain relief connectors for flexible cord and cable

UL

®

LISTED

File No. E53509

CERTIFIED

File No. LR-64107

45° elbow body, male thread

Ferrous alloy body, aluminum compression nut with washer and single hole oil-resistant grommet

Customize your installation with our 45° DBA connectors.

Like the DBL, the steel body and aluminum compression nut will provide many years of trouble free service.

Insulated throat option:

Add suffix “T” to all complete assembly part numbers on this page.

E.g.:DBKA-3513-T.

A

B†

CONDUIT

H U B

SIZE

PANEL

HOLE

SIZE

1

3

/

/

1”

2

4

C

7

1

1

/

8

1

3

/

/

8

8

CORD

DIAMETER

RANGE IN (MM)

.125-.250 (3.17-6.35)

.187-.312 (4.75-7.92)

.250-.375 (6.35-9.52)

.312-.437 (7.92-11.1)

.375-.500 (9.52-12.7)

* .437-.562 (11.1-14.3)

*.500-.625 (12.7-15.9)

.312-.375 (7.92-9.52)

.375-.437 (9.52-11.1)

.437-.500 (11.1-12.7)

.500-.562 (12.7-14.3)

.562-.625 (14.3-15.9)

.625-.687 (15.9-17.4)

*.687-.750 (17.4-19.1)

.687-.812 (17.4-14.2)

.750-.875 (19.1-22.2)

.812-.937 (14.2-23.8)

*.875-1.000 (22.2-25.4)

COMPLETE ASSEMBLY PART NUMBERS

WITH WITH WITH

COMPRESSION NUT MECHANICAL NUT WOVEN GRIP

DB-745

DB-9545

DB-845

DB-9745

DB-945

DB-9945

DB-1045

DB-113845

DB-1171645

DB-111245

DB-1191645

DB-15845

DB-11111645

DB-1145

DB-141345

DB-147845

DB-14151645

DB-1445

DBA-1204-M

DBA-1205-M

DBA-1206-M

DBA-1207-M

DBA-1208-M

DBA-1209-M

DBA-1210-M

DBA-2306-M

DBA-2307

DBA-2308-M

DBA-2309-M

DBA-2310-M

DBA-2311-M

DBA-2312-M

DBA-3513-M

DBA-3514-M

DBA-3515-M

DBA-3516-M

. . . . .

DBKA-1205

DBKA-1206

DBKA-1207

DBKA-1208

DBKA-1209

DBKA-1210

DBKA-2306

DBKA-2307

DBKA-2308

DBKA-2309

DBKA-2310

DBKA-2311

DBKA-2312

DBKA-3513

DBKA-3514

DBKA-3515

DBKA-3516

*Maximum cord size will not pass through body without removing outer jacket.

Other grommets both single and multi-hole are available–see page 70.

D†

E

C

FORM SIZE

DIMENSIONS 2

A

B †

C

D †

E

ACROSS

FLATS

F

MAX

3 5

1.13 1.25 1.63

1.31 1.56 2.31

1.31 1.38 1.44

1.96 2.21 3.12

1.38 1.38 1.75

1.66 1.66 2.06

With nut snug, grommet not compressed

F

64

FORM BODY

SIZE BORE–IN (MM)

2

3

5

DB-945-A

.56 (14.3)

DB-1145-A

.75 (19.1)

DB-1445-A

1.03 (26.2)

GROMMET

DB-9-F

DB-9-V

DB-9-E

DB-9-J

DB-9-D

DB-9-U

DB-9-C

DB-11-V

DB-11-E

DB-11-D

DB-11-R

DB-11-K

DB-11-O

DB-11-C

DB-14-K

DB-14-H

DB-14-L

DB-14-C

PLAIN

WASHER

PX-8-CS

PX-11-CS

PX-14-CS

COMPONENT PART NUMBERS

COMPRESSION

NUT

MECHANICAL

NUT

DB-9-B

DB-11-B

DB-14-B

PX-10

PX-11

PX-14

WOVEN

GRIP

WOVEN GRIP WOVEN GRIP

WASHER NUT

. . . . .

DBKG-5

DBKG-6

DBKG-8

DBKG-8

DBKG-10

. . . . .

DBKG-10 PX-8-C

DBK-9-B

DBKG-6

DBKG-8

DBK-11-W

DBK-11-W

DBKG-8 DBK-11-W

DBKG-10 DBK-11-W

DBKG-10 DBK-11-W

DBKG-12 PX-11-CS

DBKG-12 PX-11-CS

DBKG-14

DBKG-14

DBKG-16 PX-14-CS

DBKG-16 PX-14-CS

Not required

DBK-11-B

DBK-14-B

65

DBF GROUP

Strain-relief connectors for flexible cord and cable

Straight body, female thread

Aluminum body and compression nut with single hole oil-resistant grommet

UL

®

LISTED

File No. E53509

CERTIFIED

File No. LR-64107

For panelboard and bulkhead installations, as well as for drop cords and cables from overhead power sources. Also for mounting to existing threaded conduit and to conduit nipples.

CONDUIT PANEL

H U B

SIZE

HOLE

SIZE

3

/

8

11

/

16

1

3

/

2

1”

7

/

4

” 1

1

/

8

1

3

/

/

8

8

CORD

DIAMETER

RANGE IN (MM)

.125-.187 (3.17-4.75)

.187-.250 (4.75-6.35)

.250-.312 (6.35-7.92)

.312-.375 (7.92-7.52)

.375-.437 (9.52-11.1)

.125-.187 (3.17-4.75)

.187-.250 (4.75-6.35)

.250-.312 (6.35-7.92)

.312-.375 (7.92-9.52)

.375-.437 (9.52-11.1)

.125-.250 (3.17-6.35)

.187-.312 (4.75-7.92)

.250-.375 (6.35-9.52)

.312-.437 (7.92-11.1)

.375-.500 (9.52-12.7)

.437-.562 (11.1-14.3)

.500-.625 (12.7-15.9)

.125-.250 (3.17-6.35)

.187-.312 (4.75-7.92)

.250-.375 (6.35-9.52)

.312-.437 (7.92-11.1)

.375-.500 (9.52-12.7)

.437-.562 (11.1-14.3)

.500-.625 (12.7-25.4)

.625-.687 (15.9-17.4)

.687-.750 (17.4-19.1)

.687-.812 (17.4-20.6)

.750-.875 (19.1-22.2)

.812-.937 (20.6-23.8)

.875-.937 (22.2-25.4)

A

E

MAX

DBF-614

DBF-6516

DBF-638

DBF-6716

DBF-612

DBF-6916

DBF-6

DBF-111116

DBF-11

DBF-1413

DBF-1478

DBF-141516

DBF-14

COMPLETE ASSEMBLY PART NUMBERS

WITH WITH WITH

COMPRESSION NUT MECHANICAL NUT WOVEN GRIP

DBF--4316

DBF-414

DBF-4516

DBF-438

DBF-4

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DBF-3316

DBF-314

DBF-3516

DBF-338

DBF-3

DBF-7

DBF-9516

DBF-8

DBF-9716

DBF-9

DBF-9916

DBF-10

Use Form 2

DBF-1204-M

DBF-1205-M

DBF-1206-M

DBF-1207-M

DBF-1208-M

DBF-1209-M

DBF-1210-M

Use Form 2

. . . . .

DBKF-1205

DBKF-1206

DBKF-1207

DBKF-1208

DBKF-1209

DBKF-1210

DBF-2204-M

DBF-2205-M

DBF-2206-M

DBF-2207-M

DBF-2208-M

DBF-2209-M

DBF-2210-M

DBF-2311-M

DBF-2312-M

DBF-3513-M

DBF-3514-M

DBF-3515-M

DBF-3516-M

. . . . .

DBKF-2205

DBKF-2206

DBKF-2207

DBKF-2208

DBKF-2209

DBKF-2210

DBKF-2311

DBKF-2312

DBKF-3513

DBKF-3514

DBKF-3515

DBKF-3516

D

FORM SIZE

DIMENSIONS 1 2 3 5

A

B †

C †

D

E

MAX

.88 1.13 1.25 1.63

1.53 1.84 2.05 2.59

– 2.49 2.70 3.40

– 1.38 1.38 1.75

– 1.66 1.66 2.06

†With nut snug, grommet not compressed.

C*

B*

66

FORM

SIZE

BODY

BORE–IN (MM)

1

1

2

2

3

5

DBF-4-A

.440 (11.2)

DBF-3-A

.440 (11.2)

DBF-9-A

.620 (15.7)

DBF-6-A

.620 (15.7)

DBA-11-A

.750 (19.1)

DBF-14-A

1.030 (26.2)

GROMMET

DB-4-F

DB-4-J

DB-4-D

DB-4-E

DB-4-C

DB-4-F

DB-4-J

DB-4-D

DB-4-E

DB-4-C

DB-9-F

DB-9-V

DB-9-E

DB-9-J

DB-9-D

DB-9-V

DB-9-C

DB-9-F

DB-9-V

DB-9-E

DB-9-J

DB-9-D

DB-9-V

DB-9-C

DB-11-O

DB-11-C

DB-14-K

DB-14-H

DB-14-L

DB-14-C

PLAIN

WASHER

PX-4-CS

PX-4-CS

PS-8-CS

PX-8-CS

PX-11-CS

PX-14-CS

COMPONENT PART NUMBERS

COMPRESSION MECHANICAL WOVEN

NUT NUT GRIP

DB-4-B

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DB-4-B

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DB-9-B PX-10

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DBKG-5

DBKG-6

DBKG-8

DBKG-8

DBKG-10

DBKG-10

DB-9-B

DB-11-B

DB-14-B

PX-10

PX-11

PX-14

. . . . .

DBKG-5

DBKG-6

DBKG-8

DBKG-8

DBKG-10

DBKG-10

. . . . .

PX-8-CS

DBKG-12

DBKG-12

PX-11-CS

PX-11-CS

DBKF-14

DBKG-14

DBKG-16

PX-14-CS

DBKFG-16 PX-14-CS

WOVEN GRIP

WASHER

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

PX-8-CS

*FLARED NIPPLE

Used for mounting type DBF connectors on sheet metal boxes and cabinets, and for drop cords/cables from overhead power distribution ducts.

Flared Nipple not included unless specially ordered.

To include flared nipple with assembly change catalog numbers as follows:

• with compression nut, change DBF to DHF

• with mechanical nut, change DBF to DBH

• with weave grip, change DBKF to DBKH

WOVEN GRIP FLARED

NUT NIPPLE*

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DH-38

. . . . .

. . . . .

. . . . .

. . . . .

. . . . .

DH-1

DBK-9-B

. . . . .

DBK-9-B

DBK-11-B

DBK-14-B

DH-1

DH-2

DH-2

DH-3

DIMENSIONS

HUB MAX. PANEL PART

SIZE THICKNESS NO.

3/8”

1/2”

1/8”

3/16”

DH-38

DH-1

A

.86

1.00

B C

.44 .33

.56 .44

D

.12

.12

E

.09

.12

F

.69

.86

3/4”

1”

3/16”

1/4”

DH-2

1.25

.80 .44

.12

.12

1.09

DH-3

1.50 1.00 .56

.19

.16

1.36

E

B

F – Recommended minimum clearance

(Standard knockouts satisfactory).

A

C D

67

DBZP GROUP

Strain-relief panelboard and bulkhead connector

Straight body, male thread

aluminum body and compression nut with washer, gasket, and single hole oil-resistant grommet

These bulkhead mounting cord connectors have an oil-resistant rubber gasket furnished with each body which permits mounting from either the front or the back of panels and bulkheads.

Where 45° angle mounting is required, choose adapters listed on page 72.

As with the other DB Series grips, the DBZP provides effective strain-relief and is liquid-tight through the assembled unit.

Note: See page 72 for information on

Panelboard Adapters & Conduit

Fitting Boxes

CONDUIT

H U B

SIZE

1

1

2

2

3

3

7

3

7

3

/

/

/

/

/

8

8

8

8

8

”*

”*

”*

”*

”*

CORD

DIAMETER

RANGE IN (MM)

.062- .125 (1.57-3.17)

.125- .250 (3.17-6.35)

.250- .375 (6.35-9.52)

.375- .500 (9.52-12.7)

.500- .625 (12.7-15.9)

.625- .750 (15.9-19.1)

.750- .875 (19.1-22.2)

.750- .875 (19.1-22.2)

.875-1.000 (22.2-25.4)

1.000-1.125 (25.4-28.6)

1.125-1.250 (28.6-31.8)

1.250-1.375 (31.8-34.9)

1.250-1.375 (31.8-34.9)

1.375-1.500 (34.9-38.1)

1.500-1.625 (38.1-41.3)

1.625-1.750 (41.3-44.5)

1.750-1.875 (44.5-47.6)

1.750-1.875 (44.5-47.6)

1.875-2.000 (47.6-50.8)

2.000-2.125 (50.8-54.0)

2.125-2.250 (54.0-57.2)

2.250-2.375 (57.2-60.3)

2.250-2.375 (57.2-60.3)

2.375-2.500 (60.3-63.5)

2.500-2.625 (63.5-66.7)

2.625-2.7500 (66.7-69.9)

2.750-2.875 (69.9-73.0)

* Bore hole in panelboard

1/64” larger than

dimension “E” for

back mounting.

D†

A

B

WITH

COMPLETE ASSEMBLY PART NUMBERS

WITH WITH

COMPRESSION NUT

DBZP-502

MECHANICAL NUT WOVEN GRIP

. . . . .

. . . . .

DBZP-504

DBZP-506

DBZP-508

DBZP-510

DBZP-512

DBZP-514

. . . . .

DBZP-506-M

DBZP-508-M

DBZP-510-M

DBZP-512-M

DBZP-514-M

. . . . .

DBZP-506-K

DBZP-508-K

DBZP-510-K

DBZP-512-K

DBZP-514-K

DBZP-714

DBZP-716

DBZP-718

DBZP-720

DBZP-722

DBZP-822

DBZP-824

DBZP-826

DBZP-828

DBZP-830

DBZP-714-M

DBZP-716-M

DBZP-718-M

DBZP-720-M

DBZP-722-M

DBZP-822-M

DBZP-824-M

DBZP-836-M

DBZP-828-M

DBZP-830-M

DBZP-714-K

DBZP-716-K

DBZP-718-K

DBZP-720-K

DBZP-722-K

DBZP-822-K

DBZP-824-K

DBZP-836-K

DBZP-828-K

DBZP-830-K

DBZP-930

DBZP-032

DBZP-934

DBZP-936

DBZP-938

DBZP-1038

DBZP-1040

DBZP-1042

DBZP-1044

DBZP-1046

DBZP-930-M

DBZP-932-M

DBZP-934-M

DBZP-936-M

DBZP-938-M

DBZP-1038-M

DBZP-1040-M

DBZP-1042-M

DBZP-1044-M

DBZP-1046-M

DBZP-930-K

DBZP-932-K

DBZP-934-K

DBZP-936-K

DBZP-938-K

DBZP-1038-K

DBZP-1040-K

DBZP-1042-K

DBZP-1044-K

DBZP-1046-K

E

3/16"

Max. panel thickness for rear mounting

A B

C–Diam.

F

FORM SIZE

A

B

C

E

F

MOUNTING

HOLES

MAX MOUNTING

SCREW SIZE

D

ACROSS

FLATS

5-Z** 7-Z 8-Z 9-Z 10-Z

1

8

/

8

” 2

1

/

8

” 2

5

/

8

” 3

1

/

8

” 3

3

/

4

1 1 /

4

” 1 11 /

16

” 2 3 /

32

” 2 17 /

32

” 3 1 /

32

3 /

16

#8

” 7 /

32

#10

” 9 /

32

” 11 /

32

” 11 /

32

1

/

4

5

/

16

5

/

16

2

15

/

16

” 2

15

/

32

” 2

15

/

32

” 2

15

/

32

” 2

15

/

32

1 3 /

8

” 1 7 /

8

” 2 3 /

8

” 2 7 /

8

” 3 3 /

8

1 21 /

32

” 2 1 /

32

” 2 17 /

32

” 3 1 /

32

” 3 19 /

32

† With nut snug, buit grommet not compressed.

**No adapter avaliable for from size 5-Z

68

FORM BODY

SIZE BORE–IN (MM)

5-Z

7-Z

8-Z

9-Z

10-Z

DBZ-5-P

.937 (23.8)

DBZ-7-P

1.437 (36.5)

DBZ-8-P

1.937 (49.2)

DBZ-9-P

2.437 (61.9)

DBZP-10-P

2.875 (73.0)

GROMMET

DBZ-502

DBZ-504

DBZ-506

DBZ-508

DBZ-510

DBZ-512

DBZ-514

DBZ-714

DBZ-716

DBZ-718

DBZ-720

DBZ-722

DBZ-822

DBZ-824

DBZ-826

DBZ-828

DBZ-830

DBZ-930

DBZ-932

DBZ-934

DBZ-936

DBZ-938

DBZ-1038

DBZ-1040

DBZ-1042

DBZ-1044

DBZ-1046

PLAIN

WASHER

DBZ-504-W

DBZ-504-W

DBZ-508-W

DBZ-508-W

DBZ-512-W

DBZ-512-W

DBZ-515-W

DBZ-716-W

DBZ-716-W

DBZ-720-W

DBZ-720-W

DBZ-723-W

DBZ-824-W

DBZ-824-W

DBZ-828-W

DBZ-828-W

DBZ-831-W

DBZ-932-W

DBZ-932-W

DBZ-936-W

DBZ-936-W

DBZ-939-W

DBZP-1040-W

DBZP-1040-W

DBZP-1044-W

DBZ-1044-W

DBZ-1046-W

COMPONENT PART NUMBERS

COMPRESSION MECHANICAL

NUT NUT

. . . . .

. . . . .

DBZ-5-B

DBZ-7-M

DBZ-8-B

DBZ-9-B

DBZ-10-B

DBZ-5-M

DBZ-7-M

DBZ-8-M

DBZ-9-M

DBZ-10-M

WOVEN

GRIP

. . . . .

. . . . .

DBKG-6

WOVEN GRIP WOVEN GRIP

WASHER

. . . . .

. . . . .

LZW-9312-10A

NUT

. . . . .

. . . . .

DBKG-8

DBKG-10

LZW-9312-10A

LZW-9312-12A

DBKG-12 LZW-9312-12A

DBKG-14-Z

DBZ-5-B

DBKG-14

DBKG-16

DBKG-18

DBKG-20

DBKG-22

DBKG-22

DBKG-26

DBKG-26

DBKG-28

DBKG-28

LZW-9316-16A

LZW-9316-16A

LZW-9316-20A

LZW-9316-20A

LZW-9320-22A

DBZ-7-B

DBZ-8-B

DBKG-28

DBKG-34

DBKG-34

DBKG-38

DBKG-38

LZW-9324-28A

DBKG-38 LZW-9328-38A

DBKG-40-Z

DBKG-46-Z

DBKG-46-Z

DBKG-46-Z

DBZ-9-B

DBZ-10-B

Not required

69

GROMMETS

for DB/DBZ series connectors

UL

®

LISTED

CERTIFIED

Molded oil-resistant synthetic rubber

These tapered grommets fit in the tapered bodies of all appropriate

DB Series metallic connectors.

They provide strain-relief by gripping the cord jacket inside the grommet, and efficiently seal out water and oil from internal connections.

Amphenol ® /Pyle ® rubber grommets are specially compounded and molded to resist age-hardening, adding many more years to the life of installations.

CABLE

RANGE (inches) FORM1 FORM2 FORM 3

BLANK

.062-.125

DB-4-Z

.125-.187

DB-4-F

.125-.250

.187-.250

DB-4-J

.187-.312

DB-9-Z

DB-9-F

DB-9-V

DB-11-Z

DB-11-X

.250-.312

DB-4-D

.250-.375

.312-.375

DB-4-E

.312-.437

.375-.437

DB-4-C

DB-9-E

DB-9-J

DB-11-4

DB-11-E

DB-9-D

.375-.500

.437-.500

.437-.562

.500-.562

.500-.625

.562-.625

.562-.687

.625-.687

.625-.750

.687-.750

DB-9-U

DB-9-C

DB-11-D

DB-11-R

DB-11-K

DB-11-O

DB-11-C

.687-.812

.750-.875

.812-.937

.875-.937

.875-1.000

1.000-1.125

1.125-1.250

1.250-1.375

1.375-1.437

1.375-1.500

1.500-1.625

1.625-1.750

1.750-1.875

1.875-1.937

1.875-2.000

2.000-2.125

2.125-2.250

2.250-2.375

2.375-2.437

2.375-2.500

2.500-2.625

2.625-2.750

2.750-2.875

FORM 5

DB-14-N

DB-14-M

DB-14-E

FORM 5Z

DBZ-502

DBZ-504

DBZ-506

DBZ-508

DBZ-510

FORM 7Z FORM 8Z FORM 9Z

DBZ-706

DBZ-708

DBZ-710 DBZ-810

DB-14-J DBZ-512 DBZ-712 DBZ-812

FORM 10Z

DB-14-K

DB-14-H DBZ-514 DBZ-714 DBZ-814

DB-14-L

DBZ-515

DB-14-C DBZ-716 DBZ-816 DBZ-916

DBZ-718 DBZ-818 DBZ-918

DBZ-720 DBZ-820 DBZ-920

DBZ-722 DBZ-822 DBZ-922

DBZ-723

DBZ-824 DBZ-924

DBZ-826 DBZ-926

DBZ-828 DBZ-928

DBZ-830 DBZ-930

DBZ-831

DBZ-932

DBZ-934

DBZ-936

DBZ-938

DBZ-939 DBZ-1038

DBZ-1040

DBZ-1042

DBZ-1044

DBZ-1046

70

Multi-hole grommets

C

B

A

2

Hole

3

Hole

BODY AND

COMPRESSION

NUT USED

Form 1

Form 2

Form 5

Form 2

Form 3

A

NOMINAL SIZE

PART NO. CORD OR CABLE B C

DB-4-H

DB-9-MA

DB-9-X

DB-9-XA

DB-9-H

DB-9-O

DB-14-D

DB-9-L

DB-11-M

.170

.100

.125

.156

.250

.281

.437

.218

.281

21

/

32

15

/

16

15

/

16

15

/

16

15

/

16

15

/

16

1

9

/

32

1

1

/

32

1

15

/

16

1

/

32

5

/

8

23

/

32

3

/

8

5

/

8

5

/

8

5

/

8

5

/

8

5

/

8

Cord protecting sleeve/grommet

BODY AND

COMPRESSION

NUT USED

Form 2

A

NOMINAL SIZE B

C

OVERALL

PART NO.

CORD OR CABLE O.D.

LENGTH

DBY-9-J

.312 to .437

15

/

16

3

71

ACCESSORIES

Panelboard adapters

Aluminum construction. Accepts DBZP panelboard connectors

FORM

SIZE

PART NUMBER

All adapter covers come complete with screws and clips for mounting the connector, plus bolts, washers, and gasket for attaching cover to panel or conduit fitting box.

7-Z

8-Z

9-Z

10-Z

ZP-C-2516-12

ZP-C-2520-12

ZP-C-2524-12

ZP-C-2528-12

A B C

DIMENSIONS

D E F G

4 3 /

16

” 4 3 /

16

” 3 9 /

16

” 3 9 /

16

” 2 15 /

16

” 1 /

4

-20 x 3 /

4

” 1 11 /

16

4

1

/

2

” 4

1

/

2

” 3

8” 8” 7”

7

/

8

” 3

7”

7

/

8

” 3

39

/

64

1

/

4

-20 x

3

/

4

” 2

3

/

32

3 33 /

64

” 1 /

2

-13 x 3 /

4

” 2 17 /

32

8” 8” 7” 7” 3

5

/

8

1

/

2

-13 x

3

/

4

” 3

1

/

32

A

C

E

F

B D

G

1/16" GASKET

Conduit fitting boxes

Ferrous alloy construction

Conduit fitting box to fit adapters.

Mounting hardware is not included.

Thru-feed styles available upon request.

G

8" H

A

C

F

E

A

C

F

E

B D

H

G

B D

Form sizes 9-Z & 10-Z

CONDUIT

FORM HUB

SIZE SIZE

7-Z

8-Z

9-Z

3 /

4

1”

1

1

/

4

1

1

/

2

1

1

/

4

1

1

/

2

2”

2

1

/

2

3”

PART

NUMBER

P-202760-42

P-202760-43

P-202760-64

P-202760-65

JRZ-610064

JRZ-610065

JRZ-610066

JR-720036-A

JRZ-820036-A

72

6”

8”

A

5 1 /

4

B

5 1 /

4

6”

10

3

/

4

Form sizes 7-Z & 8-Z

DIMENSIONS

C D E F

13 /

16

4 5 /

8

” 4 5 /

8

” 2 3 /

8

” 13 /

16

1”

1”

5

1

/

4

” 5

1

/

4

” 3

3

/

4

” 1

7

/

16

6

3

/

4

” 9

1

/

2

” 3

3

/

4

” 1

7

/

8

4 1 /

2

” 2 1 /

8

G

9 /

32

DIA.

H

3 9 /

16

9

/

32

DIA.

7

/

16

DIA.

3

7

/

8

7”

Cord Grip handles

For use with Star-Line ® and other electrical devices that are tapped for conduit and use flexible cord or cable.

These handles not only fit electrical connectors, but will also work well on heavy duty portable equipment.

Both D and T handles are made of cast aluminum and come complete with a locknut on male thread “A.” Hub “B” accepts type DB cord grips with male thread (not included)

Serves also as a convenient means for hanging your plugs, receptacles or portable equipment.

TYPE PH D-HANDLE

PART

NUMBER

PH-2

PH-3

PH-5

PHA-22

PHA-33

“A” MALE

THREAD

¾”

1”

1½”

¾”

1”

“B”FEMALE

THREAD

¾”

1”

1½”

¾

1”

TYPE PHA T-HANDLE

B

A

A

B

73

Amphenol Industrial Operations

Additional Amphenol

®

/ Pyle

®

Industrial Products

Amphenol is one of the largest manufacturers of interconnect solutions worldwide. Amphenol’s broad offering of products are highly suitable for industrial applications where cable glands and cord grip products are used. Several of the Amphenol Heavy Duyy Connectors are shown here and on the next page.

For more information, please see relevant literature or Amphenol’s Website: www.amphenol-industrial.com

Star-Line

®

Heavy Duty

Connectors

Amphenol/Pyle Star-Line connectors are heavy duty environmental solutions for high amperage and high density control and instrumentation applications. They are designed to perform up to amperages of 1135 amps at 1000/VAC or

VDC rating. Other features include:

• Exceeds MIL-5015 E and R specifications

• UL listed and CSA listed

• Double lead Acme threads provide complete coupling in one turn of the coupling nut and do not clog under adverse weather conditions

• Large wiring space provided in cable housing and conduit fitting bodies.

• Operating temperatures from -67°F to +257°F

• IP67 rated for environmental sealing.

• Hard anodic coating provides dielectric strength with heat and corrosion resistance.

• 5 Shell styles with over 150 insert patterns available.

• Solder, crimp and pressure terminals available. Circuit breaking power and control types.

• Variety of backend accessories including basketweave cable grips, straight or angled adapters and receptacle mounted to junction boxes.

Typical markets include mass transportation, automotive tooling, power generation, and petrochemical. For more information ask for catalog 12-054.

Star-Line EX

®

Connectors for

Harsh/Explosive Environments

Amphenol/Pyle Star-Line EX connectors are a hybrid form of the Star-Line series with higher temperature ranges. This family shares features of the Star-Line with additional features that include:

• Ceneluc Certified for use in Zone 1-IIc locations.

• EX Certified to ATEX certification #03ATEX 1101X

• Can be terminated onto unarmored or armored and sheathed cables built to several popular standards.

• Custom cable assemblies are available

Typical markets include mass transportation, pharmaceutical, manufacturing, power generation, and petrochemical. For more information, ask for catalog 12-054.

74

Amphenol Industrial Operations

Additional Amphenol

®

/ Pyle

®

Industrial Products

Amphenol offers RADSOK ® contact technology for several industrial connectors. The RADSOK contact is designed for high amperage applications.

Star-Line

®

and MIL-5015

Connectors with RADSOK

®

Connectors enhanced with RADSOK high amperage contacts can handle up to 150% higher amperages than connectors with standard contacts. These are called Amphe-

Power™ Connectors and are currently offered in three popular industrial connector families:

• 5015 AC Series

• GT Reverse Bayonet

• Pyle P-Lok Series

Also, the Star-Line Series has inserts available with special

RADSOK contacts, and the Neptune

®

Series is offered exclusively with RADSOK contacts.

The RADSOK patented contact has a hyperbolic, stamped grid configuration within the socket cylinder. As a male pin is inserted, axial members in the female socket deflect, enabling high current flow across the connection with minimal voltage loss.

Typical markets: power generation, petrochemical, and mass transportation. For more information on RADSOK high amperage contacts, ask for Brochure SL-391,

Amphe-Power™ Connectors with RADSOK Technology.

Amphenol Neptune

®

Connectors with RADSOK

®

The Neptune ® Series is a new power connector family featuring the RADSOK contact system. Feature include:

• Machined aluminum components

• IP 68-8 rated through SIRA

• Operating temperature rated to -67°F to +225°F

• Three key design to limit cross mating.

• Anodic hardcoat plating.

• Double lead acme threads for easy coupling.

• Decreased weight and panel layout in comparison to the competition.

• Contacts are nickel silver alloy plated and they are designed for longer life/mating cycles.

The Neptune is offered exclusively with RADSOK contact technology. Currently inserts are available with 30 Amp through 400 Amp/480 volts.

Typical Markets include oil exploration equipment, convention center power distribution, geophysical trucks, portable power distribution equipment, and communication shelters. For more information on the Neptune Series of connectors ask for Product Data Sheet 192.

75

Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Amphenol

:

DB2-020P DBZM-5714-M

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement