OPTOTRONIC FIT Areas of application Product family datasheet

OPTOTRONIC FIT Areas of application Product family datasheet
Product family datasheet
OPTOTRONIC FIT
Linear / Area Constant Current – Non dimmable
Areas of application
Installation in emergency lighting systems according to
IEC 61347-2-3, appendix J
Suitable for installation in emergency lighting systems
according to EN 60598-2-22
Suitable for central battery systems according to EN
50172
Suitable for use in luminaires with flexible current setting
(Tri-Tap)
Suitable for use in emergency lighting systems (DC
capable)
Suitable for indoor SELV equivalent installations
Suitable for luminaires of protection class I
__
Product benefits
Versatile scope of application due to output power range of up to 80 W
Safety requirement due to overload, overtemperature, Hot Plug protection
High efficiency and reliability
Product features
Supply voltage: 220…240 V
Line frequency: 0 Hz, 50 Hz…60 Hz
Line voltage: 198…264 V
Safety according to EN 61347-1, 61347-2-3, 61347-2-13, 62384
Module operation according to EN 60929
RI suppression according to EN 55015:2007+A1:2007/CDN
Line harmonics according to EN 61000-3-2
Immunity according to EN 61547
Lifetime: up to 100,000 h (temperature at T = 65 °C, max. 10 % failure rate)
c
January 16, 2014, 15:23:21
OPTOTRONIC FIT
© 2014, OSRAM GmbH. All rights reserved.
Page 1 of 6
Product family datasheet
Technical data
Electrical data
__
Product description
Output power
Input voltage
DC voltage
Mains frequency
OT FIT 35/220…240/700 CS
L
35 W
198…264 V 1)
176…276 V
50…60 Hz
OT FIT 50/220…240/1A0 CS
L
55 W
198…264 V 1)
176…276 V
50…60 Hz
OT FIT 80/220…240/1A6 CS
L
80 W
198…264 V 1)
176…276 V
50…60 Hz
Product description
Output voltage
Output current
ECG efficiency
Nominal voltage
OT FIT 35/220…240/700 CS
L
27…54 V 2)
700 / 600 / 500 mA 3)
≧83 % 4)
220…240 V
OT FIT 50/220…240/1A0 CS
L
27…54 V 2)
1050 / 925 / 800 mA 3)
≧86 % 4)
220…240 V
OT FIT 80/220…240/1A6 CS
L
27…54 V 2)
1550 / 1400 / 1200 mA 3)
≧86 % 4)
220…240 V
Product description
Nominal current
Device power loss
OT FIT 35/220…240/700 CS
L
0.19 A
5.8 W 5)
OT FIT 50/220…240/1A0 CS
L
0.28 A
8.9 W 5)
OT FIT 80/220…240/1A6 CS
L
0.42 A
13.5 W 5)
Product description
Length
Width
Height
Product weight
OT FIT 35/220…240/700 CS
L
280.0 mm
30.0 mm
21.0 mm
160.00 g
OT FIT 50/220…240/1A0 CS
L
280.0 mm
30.0 mm
21.0 mm
160.00 g
OT FIT 80/220…240/1A6 CS
L
360.0 mm
30.0 mm
21.0 mm
183.00 g
1) Permitted voltage range
2) Maximum 60 V
3) ±10 %
4) At full load and 230 V
5) Maximum
Dimensions & weight
January 16, 2014, 15:23:21
OPTOTRONIC FIT
© 2014, OSRAM GmbH. All rights reserved.
Page 2 of 6
Product family datasheet
Product description
Cable cross-section,
input side
Cable cross-section,
output side
Wire preparation length,
input side
OT FIT 35/220…240/700 CS
L
0.5…1.5 mm² 1)
0.5…1.5 mm² 1)
8.5…9.5 mm
OT FIT 50/220…240/1A0 CS
L
0.5…1.5 mm² 1)
0.5…1.5 mm² 1)
8.5…9.5 mm
OT FIT 80/220…240/1A6 CS
L
0.5…1.5 mm² 1)
0.5…1.5 mm² 1)
8.5…9.5 mm
1) Solid or flexible leads
Produkt Strichzeichnungen (vermasst)
__
Product line drawing
OT FIT 35/220…240/700 CS L
Product line drawing
OT FIT 50/220…240/1A0 CS L
Colors & materials
Product description
Casing material
OT FIT 35/220…240/700 CS
L
Metal
OT FIT 50/220…240/1A0 CS
L
Metal
OT FIT 80/220…240/1A6 CS
L
Metal
January 16, 2014, 15:23:21
OPTOTRONIC FIT
© 2014, OSRAM GmbH. All rights reserved.
Page 3 of 6
Product family datasheet
Temperatures
Product description
Ambient temperature
range
Maximum temperature
at tc test point
Max.housing
temperature in case of
fault
OT FIT 35/220…240/700 CS
L
-25…+50 °C
75 °C
110 °C
OT FIT 50/220…240/1A0 CS
L
-25…+50 °C
75 °C
110 °C
OT FIT 80/220…240/1A6 CS
L
-25…+50 °C
75 °C
110 °C
Lifespan
__
Product description
ECG lifetime
OT FIT 35/220…240/700 CS
L
50000 h 1)
OT FIT 50/220…240/1A0 CS
L
50000 h 1)
OT FIT 80/220…240/1A6 CS
L
50000 h 1)
1) At maximum T / 10 % failure rate
c
Additional product data
Product description
Encapsulated
New article
OT FIT 35/220…240/700 CS
L
No
NEW
OT FIT 50/220…240/1A0 CS
L
No
NEW
OT FIT 80/220…240/1A6 CS
L
No
NEW
Product description
Dimmable
Suitable for fixtures with
prot. class
NTC input
Overheating protection
OT FIT 35/220…240/700 CS
L
No
I
No
Automatic reversible
OT FIT 50/220…240/1A0 CS
L
No
I
No
Automatic reversible
OT FIT 80/220…240/1A6 CS
L
No
I
No
Automatic reversible
Capabilities
January 16, 2014, 15:23:21
OPTOTRONIC FIT
© 2014, OSRAM GmbH. All rights reserved.
Page 4 of 6
Product family datasheet
Product description
Overload protection
Short-circuit protection
No-load proof
Maximum wiring length
ECG/lamp
OT FIT 35/220…240/700 CS
L
Automatic reversible
Automatic reversible
Yes
2.0 m
OT FIT 50/220…240/1A0 CS
L
Automatic reversible
Automatic reversible
Yes
2.0 m
OT FIT 80/220…240/1A6 CS
L
Automatic reversible
Automatic reversible
Yes
2.0 m
Certificates & standards
__
Product description
Type of protection
Standards
Approval marks –
approval
OT FIT 35/220…240/700 CS
L
IP20
acc. to EN 61347-1/acc.
to EN 61347-2-13/acc. to
EN 55015/acc. to EN
61547/acc. to EN 610003-2/acc. to EN 62384
ENEC 10 / VDE / EMC /
EL / CE
OT FIT 50/220…240/1A0 CS
L
IP20
acc. to EN 61347-1/acc.
to EN 61347-2-13/acc. to
EN 55015/acc. to EN
61547/acc. to EN 610003-2/acc. to EN 62384
ENEC 10 / VDE / EMC /
EL / CE
OT FIT 80/220…240/1A6 CS
L
IP20
acc. to EN 61347-1/acc.
to EN 61347-2-13/acc. to
EN 55015/acc. to EN
61547/acc. to EN 610003-2/acc. to EN 62384
ENEC 10 / VDE / EMC /
EL / CE
Application advice
For more detailed application information and graphics please see product datasheet.
Sales and Technical Support
Sales and Technical Support www.osram.com
Logistical Data
Product code
Product
description
Packaging unit
(Pieces/Unit)
Dimensions
(height x width x
length)
4052899032828
OT FIT
35/220…240/700
CS L
Shipping carton
box
20
- x - x -
4052899032804
OT FIT
50/220…240/1A0
Shipping carton
box
- x - x -
January 16, 2014, 15:23:21
OPTOTRONIC FIT
Volume
Gross weight
© 2014, OSRAM GmbH. All rights reserved.
Page 5 of 6
Product family datasheet
4052899032781
CS L
20
OT FIT
80/220…240/1A6
CS L
Shipping carton
box
20
- x - x -
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
January 16, 2014, 15:23:21
OPTOTRONIC FIT
© 2014, OSRAM GmbH. All rights reserved.
Page 6 of 6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement