Specifications
OPTIONS
LE-200PS
Model
Interface
LE-150PS
Standard: RS-232C /RS-422 /RS-485
Optional: TTL (Model: “OP-5M”)
DSUB 25pin female connector (M2.6)
Measurement Connecter
ASYNC, ASYNC-PPP, Character
SYNC: SYNC/BSC, Bit SYNC: HDLC/SDLC/X.25
ASYNC, ASYNC-PPP
Baud Rate
50bps~1Mbps (arbitrary)
50bps~500Kbps (arbitrary)
SYNC Clock
ST1 *1, ST2 *1, RT(RXC),
AR(clock extracted from the edge of SD/RD)
-
Protocol
ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX
Bit transmission order,Polarity
Order: LSB first/ MSB first (switchable), Polarity: Normal/ Invert (switchable)
Error Check
Parity (ODD, EVEN, MARK, SPACE), Framing, Break, Abort (LE-200PS only), Short frame (LE-200PS only), BCC (LRC,
CRC-6, CRC-12, CRC-16, CRC-ITU-T, FCS-16 (LE-200PS only) ), FCS-32 (LE-200PS only). BCC permeation mode
Memory
PC: Max. 8G byte on the HDD; PC-less: Capacity of the SD card
(specify the file size at 128K / 1M /2M / 4M / 8M byte)
Recording Type
Ring Buffer (continuous) mode, Fixed Buffer (full stop) mode
Mode
Remote mode (with PC); Data Logger mode (without PC)
Measurement start/stop
Control from PC, Start/Stop switch, Auto-Power run, Specify date and time.
Idle Time
OFF (no-record); Resolution: 100ms, 10ms, 1ms; Max. 999. 9s
Time Stamp
OFF (no record); Date time stamp: “Day/Hr/Min”, “Hr/Min/Sec” or “Min/Sec/10ms”
Record signals (RS(RTS), CS(CTS), ER(DTR), DR(DSR), CD(DCD), CI(RI), EXIN) with
transmission/reception data. Waveform display (RS-232C only)
Record only frames of the specified address.
(HDLC/SDLC/X.25 only)
Address Filter
Protocol translation display on PC
Condition
SDLC (modulo8/128),
ITU-T X. 25(modulo8/128), LAPD, PPP
PPP
Communication error, data string up to 8 characters (don’t care and bit mask available), idle time more than
the specified duration, matched timer/counter value, logic status of interface signal line, external signal.
Action
Stop measurement (offset can be set), validate/invalidate trigger condition, control timer/counter, send
specified data string, send external signal, turn on/ off the light of user-defined LED
Retrieval function on PC
Communication error, data string up to 8 characters (don’t care and bit mask available), idle time more
than the specified duration, time stamp (don’t care available), trigger-matched data.
Transmit data registered in 16 data tables (16K byte) with one press of a key.
DTE/DCE mode selectable. Pre-set the timing of line/data. Insert parity error.
Conversion
Convert data into Text or CSV format and save.
LED
4 of two-color LED: Power/ Error, Test/Record, SD/RD, User defined U1/U2
Switch
One: Run / STOP
External Trigger
Input: 1, Output: 2. 2.54mm pin header connector
SD Card
2G byte
2 – 8G byte *2
USB 2.0 Port
Mini-B connector High speed supported
Power *3
USB bus power or external DC(DC8 - 26.4V),
AC adapter: “3A-183WP09" (center +)
Power consumption: Max. 1.2W, 0.1W/DC12V when powering off
Work time during Power failure
1 sec
Ambient Temperature, Humidity
In operation:-10~+55˚C In storage: -20~+60˚C, 5 - 85%RH (No condensation)
Standard
CE(class A), EMC(EN61326-1:2006)
Dimensions, weight
86(W)×130(D)×30(H) mm, approx. 220g
PC environment
OS: Windows® XP/Vista/7 PC: PC/AT compatible
*1: It is available only for measuring RS-232C. *2: 2GB SD card is supported. LINEEYE plans to upgrade it to 8GB SDHC card in the future.
*3: AC adapter is sold separately. In the Remote mode (with PC), it runs by the USB bus power. In the Logger mode (PC-less), you need to
have the optional AC adapter (3A-183WP09) or use the optional Power Plug Cable (SIH-2PG) and external DC power.
*The photo is for illustrative purposes only.
RS-232C / RS-422 / RS-485
3A-183WP09
Communication Protocol Analyzer
Input: AC100∼240V, 50/60Hz
Output: DC9V, 2A
Plug: Center+, Outside diameter:
5.5mm, Inside diameter: 2.1mm
Standard Set
A PC-connectable communication protocol analyzer, which can also be
used as a stand-alone communication data logger that supports SD cards
Power Plug Cable
SIH-2PG
DC Plug (Outside diameter:
5.5mm, Inside diameter:
2.1mm)<–
>Y terminal: 1.8m
Supply external DC power to
the DC jack of the analyzer.
Cable clamp is included.
DSUB 9pin
Monitor Cable
LE-259M1
Branch cable for monitoring
RS-232C over general
DSUB 9pin, such as with the
PC.
Terminal Block Adapter
LE-5TB
An adapter to extract the
RS-422/485 signals on the
DSBU 25pin connector to the
terminal block.
* Sync clock signal
measured by LE-200PS
cannot be captured.
TTL Monitor Probe Pod
OP-5M
A probe pod for monitoring
TTL-Level communication
lines at 2.5V/3.3V/5V,
Multi-Protocol Supported
LE-200PS
* Cannot be used for
simulation function.
Baud Rate: Max. 1Mbps
DIN Rail Mounting
Plate for LE-series.
Async, Sync, BSC,
SDLC, HDLC, X.25, PPP
To mount the LE-150PS /
LE-200PS on the 35mm DIN
rail.
Read the instruction manual provided with the product before use and use the
product as explained in that manual. Using the product in ways not guaranteed in the
manual, connecting it to systems outside of the specified ranges and remodeling can
all cause trouble and damage. LINEEYE CO., LTD. will assume no responsibility
whatsoever for trouble or damage arising because of unauthorized ways of use.
•All brand names and product names mentioned in this catalog are trademarks or registered trademarks of their
respective companies. •Specifications and designs of products listed in this catalog are as of February 2012, and
are subject to change without notice for improvement. •Colors of actual products may differ slightly from that
listed due to printing condition. •This catalog may not be reprinted or duplicated, in part or in whole.
©2012 by LINEEYE CO., LTD.
LINEEYE CO., LTD.
Async Communication Supported
Head Office/Sales Office
Marufuku Bldg, 5F, 39-1 Karahashi Nishihiragaki-cho, Minami-ku, Kyoto, 601-8468
PHONE: 81-75-693-0161 FAX:81-75-693-0163
LE-150PS
URL http://www.lineeye.com
E-mail : info@lineeye.co.jp
Baud Rate: Max. 500Kbps
Async, PPP
* LINEEYE CO., LTD. is a venture company founded by electronic
equipment development members of the former Sekisui Chemical
Co., Ltd. with investment from the Sekisui Venture Fund.
LE-200PS
LE-150PS
LE-DIN13 PC-connectable Protocol Analyzer…x 1
DSUB 25pin monitor cable (LE-25M1)…x 1
Mini USB cable (SI-US218)…x 1
External signal I/O cable (LE-4TG)…x 1
2G byte SD card (SD-2GX)…x 1
PC software CD…x 1
Instruction Manual…x 1
Warranty…x 1
SAFETY
WARNING
2G byte SD card.
*Same as the card packed with
LE-200PS/LE-150PS.
-
Trigger
Simulation
®
SD-2GX
Wide Input AC Adapter
Data Code
Line Status Measurement
2G byte SD Card
QR-00337
ER-00094
L-12202E/LE G
Printed in Japan
RS-232C / RS-422 / RS-485
Communication Protocol Analyzer
Supports RS-232C/RS-422/RS-485 (Standard Feature)
The device comes standard with RS-232C/RS-422/RS-485 interfaces,
which are used widely in medical equipment and electronic products.
With an optional TTL probe pod (OP-5M), it can monitor TTL-level
communication at 2.5V/ 3.3V/ 5V. LE-200PS can measure Sync
communication, which has transmission/ reception clocks.
Compact Size, Simple Operation
A lightweight communication protocol analyzer has a Data Logger function to record
data in the SD card for long hours.
External Signal
Terminal
SD Card
Slot
RUN / STOP
Switch
DC Jack
USB
Connector
Two-color
LED
M3 Screw Holes *1
Measurement Connector
*1: For attaching the optional DIN rail plate. Pitch: 70mm. Depth: 3.5mm (max).
Pin Assignment of Connector (DSUB 25 pin)
Pin
[ Terminal Block Adapter (LE-5TB) ]
Signal
1
FG
2
RS-232C SD
3
RS-232C RD
4
RS-232C RS
5
RS-232C CS
6
RS-232C DR
7
GND *2
8
RS-232C CD
9
+5VDC *1
10
RS-422 RXDB+ *2
11
RS-422 RXDA- *2
12
RS-422 RXCB+ *3
13
RS-422 RXCA- *3
15
RS-232C ST2 *3
17
RS-232C RT *3
PLC
PC
Developing Device
SD
Robot
RD
SD
RD
Baud Rate
[ TTL Monitor Probe Pod (OP-5M) ]
*2
18
RS-422/485 TXDB+/TR+
19
RS-422/485 TXDA-/TR- *2
20
RS-232C ER
22
RS-232C CI
24
RS-232C ST1 *3
*1: A terminal-supplied power from analyzer. ON/OFF
switchable.
*2: LE-5TB is useful for connecting the signals.
*3: LE-200PS only.
*4: Signal pins not defined here are not connected.
Measures at Arbitrary Speed.
Monitor data at any speed by setting the baud rate of any four digits.
The high-precision timer makes it possible to record idle time and time
stamps along with data, and is not related to the performance of the PC.
[ Configuration Setting ]
Remote Mode
Logger Mode
Analysis PC
(PC connected)
Measured data is saved as log files of the specified file size in the HDD of
the PC (Remote mode) or in the SD card of the analyzer (Logger mode).
It automatically records data until reaching the specified number of files,
and then deletes the oldest
[ Record Control Setting ]
file to record the new file. Also,
it can stop measurement on
reaching the specified number
of files. It is useful
for
detecting any hindrance in
the line.
[ Recording Time ]
Two Types of Operations Based on Usage Situation.
This device can be used as a PC-connectable Protocol Analyzer for use in the lab (Remote mode), and also as a PC-less Data Logger for use at
on-site tests to record data for long hours (Logger mode).
Long Hour Recording
Record in the SD card
Capacity: 1.8G byte
9600bps
Approx. 100 Hours
230.4Kbps
Approx. 4 Hours
(e.g. 4M byte×450 files)
*: In the case of full-duplex transmission of 1K byte data at 1ms intervals.
Seamless access to communication log files
Communication log files can be viewed
in detail on a PC. It offers seamless
operation that handles a single
measurement log file even when all
files are read collectively. The
measured data can be converted into
text or CSV format to use in a word
processor and/or spreadsheet software.
[ Text Conversion Setting ]
Easy-to-Operate Simulation Function
It incorporates an easy-to-use simulation function that makes it possible
to transmit preset transmission data (16 types of data), or fixed data such
as FOX messages, at the flip of a key while checking reception data.
(PC less)
[ Example of Simulation ]
It is useful in the situations of:
Connect to PC
via USB
Record in the HDD of PC
[ Data display example ]
*There are space limitations.
*PC usage is not allowed.
*Dusty places (PC cannot be used).
*Need to record data for more than one month.
*Cannot operate the analyzer well
Schedule Measurement by Inner RTC
Real Time Clock (RTC) backed up by
the battery of the analyzer makes it
possible to specify the starting and
ending times of the measurement. After
the measurement, it turns off the power
automatically and saves on power
consumption.
Communication errors can be detected with high reliability.
[ Auto RUN/STOP setting ]
Protects important data from corruption due to power failure
A newly developed instant power failure prevention circuit protects important
communication log files stored in the SD cards, by protecting the SD cards
from being corrupted even if power fails while recording data to the SD card.
Small and robust housing suitable for severe field environments
The palm-sized robust unit can be used between –10 to
+55̊C. It operates not only on USB bus power, but also on
external DC power of 8 to 26.4V. The consumption current
is as low as 100mA at DC12V input. The SD card slot and
the USB connector are equipped with a dust-proof cover
that allows 2-way operation. It can be fixed easily to the
equipment to be examined or built into an inspection line,
since it is compatible with 35mm DIN rails.
[ Onto 35mm DIN Rail ]
[ Data display example (Control line information is displayed.) ]
[ Dust-proof Covers ]
It can judge parity error, framing error, BCC error of various block check
codes, and short SDLC/HDLC frame (LE-200PS only). It can find the
communication sequence in the event of an error, by setting an
application-level error notification character string to the character string
agreement criteria of the triggering function. It can notify an error to
external devices and alert a communication error in the logger mode
(with a panel LED lighting), by specifying an external trigger signal
output and user-defined LED lighting as a triggering action.
[ Trigger Setting ]
[ Simulation Data Tables ]
RS-232C / RS-422 / RS-485
Communication Protocol Analyzer
Supports RS-232C/RS-422/RS-485 (Standard Feature)
The device comes standard with RS-232C/RS-422/RS-485 interfaces,
which are used widely in medical equipment and electronic products.
With an optional TTL probe pod (OP-5M), it can monitor TTL-level
communication at 2.5V/ 3.3V/ 5V. LE-200PS can measure Sync
communication, which has transmission/ reception clocks.
Compact Size, Simple Operation
A lightweight communication protocol analyzer has a Data Logger function to record
data in the SD card for long hours.
External Signal
Terminal
SD Card
Slot
RUN / STOP
Switch
DC Jack
USB
Connector
Two-color
LED
M3 Screw Holes *1
Measurement Connector
*1: For attaching the optional DIN rail plate. Pitch: 70mm. Depth: 3.5mm (max).
Pin Assignment of Connector (DSUB 25 pin)
Pin
[ Terminal Block Adapter (LE-5TB) ]
Signal
1
FG
2
RS-232C SD
3
RS-232C RD
4
RS-232C RS
5
RS-232C CS
6
RS-232C DR
7
GND *2
8
RS-232C CD
9
+5VDC *1
10
RS-422 RXDB+ *2
11
RS-422 RXDA- *2
12
RS-422 RXCB+ *3
13
RS-422 RXCA- *3
15
RS-232C ST2 *3
17
RS-232C RT *3
PLC
PC
Developing Device
SD
Robot
RD
SD
RD
Baud Rate
[ TTL Monitor Probe Pod (OP-5M) ]
*2
18
RS-422/485 TXDB+/TR+
19
RS-422/485 TXDA-/TR- *2
20
RS-232C ER
22
RS-232C CI
24
RS-232C ST1 *3
*1: A terminal-supplied power from analyzer. ON/OFF
switchable.
*2: LE-5TB is useful for connecting the signals.
*3: LE-200PS only.
*4: Signal pins not defined here are not connected.
Measures at Arbitrary Speed.
Monitor data at any speed by setting the baud rate of any four digits.
The high-precision timer makes it possible to record idle time and time
stamps along with data, and is not related to the performance of the PC.
[ Configuration Setting ]
Remote Mode
Logger Mode
Analysis PC
(PC connected)
Measured data is saved as log files of the specified file size in the HDD of
the PC (Remote mode) or in the SD card of the analyzer (Logger mode).
It automatically records data until reaching the specified number of files,
and then deletes the oldest
[ Record Control Setting ]
file to record the new file. Also,
it can stop measurement on
reaching the specified number
of files. It is useful
for
detecting any hindrance in
the line.
[ Recording Time ]
Two Types of Operations Based on Usage Situation.
This device can be used as a PC-connectable Protocol Analyzer for use in the lab (Remote mode), and also as a PC-less Data Logger for use at
on-site tests to record data for long hours (Logger mode).
Long Hour Recording
Record in the SD card
Capacity: 1.8G byte
9600bps
Approx. 100 Hours
230.4Kbps
Approx. 4 Hours
(e.g. 4M byte×450 files)
*: In the case of full-duplex transmission of 1K byte data at 1ms intervals.
Seamless access to communication log files
Communication log files can be viewed
in detail on a PC. It offers seamless
operation that handles a single
measurement log file even when all
files are read collectively. The
measured data can be converted into
text or CSV format to use in a word
processor and/or spreadsheet software.
[ Text Conversion Setting ]
Easy-to-Operate Simulation Function
It incorporates an easy-to-use simulation function that makes it possible
to transmit preset transmission data (16 types of data), or fixed data such
as FOX messages, at the flip of a key while checking reception data.
(PC less)
[ Example of Simulation ]
It is useful in the situations of:
Connect to PC
via USB
Record in the HDD of PC
[ Data display example ]
*There are space limitations.
*PC usage is not allowed.
*Dusty places (PC cannot be used).
*Need to record data for more than one month.
*Cannot operate the analyzer well
Schedule Measurement by Inner RTC
Real Time Clock (RTC) backed up by
the battery of the analyzer makes it
possible to specify the starting and
ending times of the measurement. After
the measurement, it turns off the power
automatically and saves on power
consumption.
Communication errors can be detected with high reliability.
[ Auto RUN/STOP setting ]
Protects important data from corruption due to power failure
A newly developed instant power failure prevention circuit protects important
communication log files stored in the SD cards, by protecting the SD cards
from being corrupted even if power fails while recording data to the SD card.
Small and robust housing suitable for severe field environments
The palm-sized robust unit can be used between –10 to
+55̊C. It operates not only on USB bus power, but also on
external DC power of 8 to 26.4V. The consumption current
is as low as 100mA at DC12V input. The SD card slot and
the USB connector are equipped with a dust-proof cover
that allows 2-way operation. It can be fixed easily to the
equipment to be examined or built into an inspection line,
since it is compatible with 35mm DIN rails.
[ Onto 35mm DIN Rail ]
[ Data display example (Control line information is displayed.) ]
[ Dust-proof Covers ]
It can judge parity error, framing error, BCC error of various block check
codes, and short SDLC/HDLC frame (LE-200PS only). It can find the
communication sequence in the event of an error, by setting an
application-level error notification character string to the character string
agreement criteria of the triggering function. It can notify an error to
external devices and alert a communication error in the logger mode
(with a panel LED lighting), by specifying an external trigger signal
output and user-defined LED lighting as a triggering action.
[ Trigger Setting ]
[ Simulation Data Tables ]
Specifications
OPTIONS
LE-200PS
Model
Interface
LE-150PS
Standard: RS-232C /RS-422 /RS-485
Optional: TTL (Model: “OP-5M”)
DSUB 25pin female connector (M2.6)
Measurement Connecter
ASYNC, ASYNC-PPP, Character
SYNC: SYNC/BSC, Bit SYNC: HDLC/SDLC/X.25
ASYNC, ASYNC-PPP
Baud Rate
50bps~1Mbps (arbitrary)
50bps~500Kbps (arbitrary)
SYNC Clock
ST1 *1, ST2 *1, RT(RXC),
AR(clock extracted from the edge of SD/RD)
-
Protocol
ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX
Bit transmission order,Polarity
Order: LSB first/ MSB first (switchable), Polarity: Normal/ Invert (switchable)
Error Check
Parity (ODD, EVEN, MARK, SPACE), Framing, Break, Abort (LE-200PS only), Short frame (LE-200PS only), BCC (LRC,
CRC-6, CRC-12, CRC-16, CRC-ITU-T, FCS-16 (LE-200PS only) ), FCS-32 (LE-200PS only). BCC permeation mode
Memory
PC: Max. 8G byte on the HDD; PC-less: Capacity of the SD card
(specify the file size at 128K / 1M /2M / 4M / 8M byte)
Recording Type
Ring Buffer (continuous) mode, Fixed Buffer (full stop) mode
Mode
Remote mode (with PC); Data Logger mode (without PC)
Measurement start/stop
Control from PC, Start/Stop switch, Auto-Power run, Specify date and time.
Idle Time
OFF (no-record); Resolution: 100ms, 10ms, 1ms; Max. 999. 9s
Time Stamp
OFF (no record); Date time stamp: “Day/Hr/Min”, “Hr/Min/Sec” or “Min/Sec/10ms”
Record signals (RS(RTS), CS(CTS), ER(DTR), DR(DSR), CD(DCD), CI(RI), EXIN) with
transmission/reception data. Waveform display (RS-232C only)
Record only frames of the specified address.
(HDLC/SDLC/X.25 only)
Address Filter
Protocol translation display on PC
Condition
SDLC (modulo8/128),
ITU-T X. 25(modulo8/128), LAPD, PPP
PPP
Communication error, data string up to 8 characters (don’t care and bit mask available), idle time more than
the specified duration, matched timer/counter value, logic status of interface signal line, external signal.
Action
Stop measurement (offset can be set), validate/invalidate trigger condition, control timer/counter, send
specified data string, send external signal, turn on/ off the light of user-defined LED
Retrieval function on PC
Communication error, data string up to 8 characters (don’t care and bit mask available), idle time more
than the specified duration, time stamp (don’t care available), trigger-matched data.
Transmit data registered in 16 data tables (16K byte) with one press of a key.
DTE/DCE mode selectable. Pre-set the timing of line/data. Insert parity error.
Conversion
Convert data into Text or CSV format and save.
LED
4 of two-color LED: Power/ Error, Test/Record, SD/RD, User defined U1/U2
Switch
One: Run / STOP
External Trigger
Input: 1, Output: 2. 2.54mm pin header connector
SD Card
2G byte
2 – 8G byte *2
USB 2.0 Port
Mini-B connector High speed supported
Power *3
USB bus power or external DC(DC8 - 26.4V),
AC adapter: “3A-183WP09" (center +)
Power consumption: Max. 1.2W, 0.1W/DC12V when powering off
Work time during Power failure
1 sec
Ambient Temperature, Humidity
In operation:-10~+55˚C In storage: -20~+60˚C, 5 - 85%RH (No condensation)
Standard
CE(class A), EMC(EN61326-1:2006)
Dimensions, weight
86(W)×130(D)×30(H) mm, approx. 220g
PC environment
OS: Windows® XP/Vista/7 PC: PC/AT compatible
*1: It is available only for measuring RS-232C. *2: 2GB SD card is supported. LINEEYE plans to upgrade it to 8GB SDHC card in the future.
*3: AC adapter is sold separately. In the Remote mode (with PC), it runs by the USB bus power. In the Logger mode (PC-less), you need to
have the optional AC adapter (3A-183WP09) or use the optional Power Plug Cable (SIH-2PG) and external DC power.
*The photo is for illustrative purposes only.
RS-232C / RS-422 / RS-485
3A-183WP09
Communication Protocol Analyzer
Input: AC100∼240V, 50/60Hz
Output: DC9V, 2A
Plug: Center+, Outside diameter:
5.5mm, Inside diameter: 2.1mm
Standard Set
A PC-connectable communication protocol analyzer, which can also be
used as a stand-alone communication data logger that supports SD cards
Power Plug Cable
SIH-2PG
DC Plug (Outside diameter:
5.5mm, Inside diameter:
2.1mm)<–
>Y terminal: 1.8m
Supply external DC power to
the DC jack of the analyzer.
Cable clamp is included.
DSUB 9pin
Monitor Cable
LE-259M1
Branch cable for monitoring
RS-232C over general
DSUB 9pin, such as with the
PC.
Terminal Block Adapter
LE-5TB
An adapter to extract the
RS-422/485 signals on the
DSBU 25pin connector to the
terminal block.
* Sync clock signal
measured by LE-200PS
cannot be captured.
TTL Monitor Probe Pod
OP-5M
A probe pod for monitoring
TTL-Level communication
lines at 2.5V/3.3V/5V,
Multi-Protocol Supported
LE-200PS
* Cannot be used for
simulation function.
Baud Rate: Max. 1Mbps
DIN Rail Mounting
Plate for LE-series.
Async, Sync, BSC,
SDLC, HDLC, X.25, PPP
To mount the LE-150PS /
LE-200PS on the 35mm DIN
rail.
Read the instruction manual provided with the product before use and use the
product as explained in that manual. Using the product in ways not guaranteed in the
manual, connecting it to systems outside of the specified ranges and remodeling can
all cause trouble and damage. LINEEYE CO., LTD. will assume no responsibility
whatsoever for trouble or damage arising because of unauthorized ways of use.
•All brand names and product names mentioned in this catalog are trademarks or registered trademarks of their
respective companies. •Specifications and designs of products listed in this catalog are as of February 2012, and
are subject to change without notice for improvement. •Colors of actual products may differ slightly from that
listed due to printing condition. •This catalog may not be reprinted or duplicated, in part or in whole.
©2012 by LINEEYE CO., LTD.
LINEEYE CO., LTD.
Async Communication Supported
Head Office/Sales Office
Marufuku Bldg, 5F, 39-1 Karahashi Nishihiragaki-cho, Minami-ku, Kyoto, 601-8468
PHONE: 81-75-693-0161 FAX:81-75-693-0163
LE-150PS
URL http://www.lineeye.com
E-mail : info@lineeye.co.jp
Baud Rate: Max. 500Kbps
Async, PPP
* LINEEYE CO., LTD. is a venture company founded by electronic
equipment development members of the former Sekisui Chemical
Co., Ltd. with investment from the Sekisui Venture Fund.
LE-200PS
LE-150PS
LE-DIN13 PC-connectable Protocol Analyzer…x 1
DSUB 25pin monitor cable (LE-25M1)…x 1
Mini USB cable (SI-US218)…x 1
External signal I/O cable (LE-4TG)…x 1
2G byte SD card (SD-2GX)…x 1
PC software CD…x 1
Instruction Manual…x 1
Warranty…x 1
SAFETY
WARNING
2G byte SD card.
*Same as the card packed with
LE-200PS/LE-150PS.
-
Trigger
Simulation
®
SD-2GX
Wide Input AC Adapter
Data Code
Line Status Measurement
2G byte SD Card
QR-00337
ER-00094
L-12202E/LE G