Installing New Pump
13 Adjust Pump Dial to the 2 o’clock position
(2 clicks).
Connector
Screw
16 Replace and screw in the Connector Screw so it is hand-tight (no power tools, please!)
Filter
14 Insert the new Pump into the Pump Tower making sure that: a. The rubber feet of the Pump are facing up.
b. The Pump Connector Wire goes behind
and underneath the Pump.
c. Pump Cover Plate is snapped back onto
top of Pump.
17 Place Pump Filter back into slot.
18 Place Grow Surface upright on towel and gently replace plants back into their original positions on the Grow Surface.
19
Place Grow Surface back into bowl and replace bowl on the Base. Press down firmly on the Grow Surface.
Congratulations...
You have replaced your
AeroGarden Pump!
Wire Slot
Metal
Contact
15 Plug the Pump Connector into the Grow
Surface so that the Metal Contacts face up and out and the Connector Wire is inside the
Wire Slot.
©2006 AeroGrow International, Inc
If you have any questions please feel free to contact Customer Service:
1-800-GROW-NOW (1-800-476-9669) or email: info @ aerogrow.com
300177AA
I N T E R N A T I O N A L , I N C .
TM
Directions for Replacing AeroGarden Pump
Grow Surface Grow Surface
Opening
Upside Down Grow Surface:
Pump Cover Plate
Filter
Pump
Tower
Wire Slot
Tools Needed:
• Flat-head screwdriver
• Phillips-head screwdriver
• Needle-nose pliers
Bowl
Removing Old Pump
1
2
3
Unplug AeroGarden.
Remove the Bowl from the
Base. Do not empty the water.
Remove the Grow Surface from the Bowl and place on a counter covered by a towel (your roots will be dripping with water).
Hint: Lift the View Door and slide one hand into the Bowl to lift.
Don’t worry if you gently tear some roots.
View Door
7
Remove the Pump Connector
Screw in the Pump Connector using a Phillips-head screwdriver.
Pump
Connector
Wire
Pump
Connector
Pump
Connector
Screw
Pump
4
5
6
Gently remove each plant from its Grow Surface
Opening and place the plants upright in the Bowl so that the roots are in the water.
Hint: Note where the plants were positioned on the Grow Surface.
Turn the Grow Surface upside down on the towel, with the back of the Pump
Tower facing you. (see top right photo)
Take out Pump Filter, rinse it (no soap) and set it aside.
8
Pull up on Pump Connector to disconnect it from the bottom of the Grow Surface.
10
Remove the Pump by inserting the flat-head screwdriver into the space under the pump.
Push down on the handle of the screwdriver to lift the Pump out of the Pump Tower.
11
Pull wire out of Wire Slot.
Discard old Pump in trash.
Part A
9
Remove Pump Cover Plate – insert flat-head screwdriver into each of the 3 rectangular slots and turn screwdriver 90 to help pry out the cover plate.
It is okay to use force.
12
Remove part A with needle-nose pliers and discard in trash.
Directions continued on back
Installing New Pump
13 Adjust Pump Dial to the 2 o’clock position
(2 clicks).
Connector
Screw
16 Replace and screw in the Connector Screw so it is hand-tight (no power tools, please!)
Filter
14 Insert the new Pump into the Pump Tower making sure that: a. The rubber feet of the Pump are facing up.
b. The Pump Connector Wire goes behind
and underneath the Pump.
c. Pump Cover Plate is snapped back onto
top of Pump.
17 Place Pump Filter back into slot.
18
Place Grow Surface upright on towel and gently replace plants back into their original positions on the Grow Surface.
19
Place Grow Surface back into bowl and replace bowl on the Base. Press down firmly on the Grow Surface.
Congratulations...
You have replaced your
AeroGarden Pump!
Wire Slot
Metal
Contact
15 Plug the Pump Connector into the Grow
Surface so that the Metal Contacts face up and out and the Connector Wire is inside the
Wire Slot.
©2006 AeroGrow International, Inc
If you have any questions please feel free to contact Customer Service:
1-800-GROW-NOW (1-800-476-9669) or email: info @ aerogrow.com
300177AA
I N T E R N A T I O N A L , I N C .
TM
Directions for Replacing AeroGarden Pump
Grow Surface Grow Surface
Opening
Upside Down Grow Surface:
Pump Cover Plate
Filter
Pump
Tower
Wire Slot
Tools Needed:
• Flat-head screwdriver
• Phillips-head screwdriver
• Needle-nose pliers
Bowl
Removing Old Pump
1
2
3
Unplug AeroGarden.
Remove the Bowl from the
Base. Do not empty the water.
Remove the Grow Surface from the Bowl and place on a counter covered by a towel (your roots will be dripping with water).
Hint: Lift the View Door and slide one hand into the Bowl to lift.
Don’t worry if you gently tear some roots.
View Door
7
Remove the Pump Connector
Screw in the Pump Connector using a Phillips-head screwdriver.
Pump
Connector
Wire
Pump
Connector
Pump
Connector
Screw
Pump
4
5
6
Gently remove each plant from its Grow Surface
Opening and place the plants upright in the Bowl so that the roots are in the water.
Hint: Note where the plants were positioned on the Grow Surface.
Turn the Grow Surface upside down on the towel, with the back of the Pump
Tower facing you. (see top right photo)
Take out Pump Filter, rinse it (no soap) and set it aside.
8
Pull up on Pump Connector to disconnect it from the bottom of the Grow Surface.
10
Remove the Pump by inserting the flat-head screwdriver into the space under the pump.
Push down on the handle of the screwdriver to lift the Pump out of the Pump Tower.
11
Pull wire out of Wire Slot.
Discard old Pump in trash.
Part A
9
Remove Pump Cover Plate – insert flat-head screwdriver into each of the 3 rectangular slots and turn screwdriver 90 to help pry out the cover plate.
It is okay to use force.
12
Remove part A with needle-nose pliers and discard in trash.
Directions continued on back