advertisement
COLONY/COLONY SOFT
Installation
Instructions
Bidet Faucet and Transfer Valve
3475.301
3475.501
with SpeedConnect™ Drain
Congratulations on purchasing your American
Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
SpeedConnect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Certified to comply with ANSI A112.18.1
M 9 6 8 7 9 6 R e v. 1 . 1
*Your new American Standard faucet is designed to work only with the SpeedConnect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Roughing-in Dimensions
TRANSFER VALVE
(FOR FLUSHING
RIM OR SPRAY)
FINISHED
WALL
BIDET OUTLINE
IS SYMBOLIC 7/8 DIA.
Required tools
(C)
8 TO 12
(H)
DIVERTER AND
VACUUM BREAKER
ASSEMBLY
2-1/4
DIA.
Screwdriver
DOUCHE
SPRAY
ADJ. 1-1/4
TO 2-1/4
2-1/8
DIA.
1-3/16 DIA.
1-1/4 MAX.
4-1/4
Phillips Screwdriver
3-7/8
1-3/8
DIA.
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
FINISHED
FLOOR
REAR VIEW WITH
WALL REMOVED
5-1/2
1-1/4 O.D. TAILPIECE
1
BIDET FAUCET INSTALLATION
CAUTION
Place RUBBER RING (10) into ADAPTER (4).
Turn off hot and cold water supplies before beginning.
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above mounting surface top. Fig. A. Thread ADAPTER (4) onto VALVE BODIES (3, 3a) until snug against internal stop. If necessary, adjust LOCKNUT (1).
Tighten LOCKNUTS (1) with WRENCH (5) (supplied) to secure VALVE BODIES (3, 3a).
Remove MOUNTING NUT (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward hole of BIDET.
Replace UPPER GASKET (8) and WASHER (7) . Position the side threaded outlet rearward and secure MOUNTING
NUT (6). Thread ESCUTCHEON (11) onto TRANSFER
VALVE (9) until it seats against the BIDET LEDGE.
Fig. A.
5/16''
MIN.
3, 3a
2 8
SPRAY INSTALLATION
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside of SPRAY BODY FLANGE (2) and secure with NUT (3).
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
7
6
Adjustable Wrench
4
10
4
10
MOUNTING
SURFACE
2
2
1
1
5
4
11
HOT
3
2
PUTTY
3
Plumbers' Putty or
Caulking
Channel Locks
Tubing Cutter
6
7
9
8
COLD
3a
9
1
5
4
BIDET
LEDGE
1
3
POP-UP DRAIN
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B.
Fig. A.
1
3
2
4
REMOVE FLANGE
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain body.
Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
Fig. A.
1
2
4
3
Fig. B.
Fig. B.
DRAIN
BODY
7
5 INSTALL DRAIN FROM
BELOW FIXTURE
From under side of BIDET install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards the rear of the BIDET.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body from above BIDET and tighten
FLANGE (4) firmly.
4
3
DRAIN
OUTLET
1
2
6
TIGHTEN LOCKNUT
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
7
FLANGE GASKET
Check DRAIN FLANGE in BIDET to ensure that WHITE
FOAM GASKET (1) is fully compressed and not visible.
Fig. A.
POP-UP ROD ASSEMBLY
Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2) through rear hole, making sure SEAL WASHER (3) is properly seated. Fig. B.
From below slip slot in MOUNTING NUT (4) over CABLE (5).
Thread NUT (4) onto lift rod guide shank to secure ROD
GUIDE (1) to bidet. Hand tighten only. Fig. B.
Fig. A.
DRAIN
FLANGE
1
WHITE FOAM
GASKET
NOT VISIBLE
2
1
Fig. B.
3
1
5
ILLUSTRATION
SHOWN LESS
VALVES
SLOTTED
MOUNTING
NUT
4
2
M 9 6 8 7 9 6 R e v. 1 . 1
8 ATTACH CABLE
CONNECTOR
POP-UP KNOB (1) must be fully down. Fig. A.
Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY
CONNECTION (2) and hand tighten. Fig. B.
Your new POP-UP DRAIN installation is now complete.
Fig. C.
Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. C.
Fig. A.
DOWN
9
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
INSTALL DIVERTER KNOB
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).
Push on RING (3) and tighten with SCREW (4).
Press on KNOB CAP (5).
Note: Screwdriver gap is for disassembling and should point downwards.
2
Fig. B.
10
TEE AND HOSE CONNECTION
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to bottom of TRANSFER VALVE (3).
Install SEAL (4) into coupling nut of TEE (5) and tighten connection to ADAPTER (2).
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve bodies and securely tighten.
2
WATER SUPPLY CONNECTION
7
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
Connect water supply to VALVE BODIES (7,7a) with
1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE
RISERS (3). Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
1/2" PIPE
THREAD
2
FLEXIBLE
SUPPLIES
Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors, and COUPLING NUTS.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.
HOT
6
1
5
1
1
Fig. C.
3
4
2
6
1-1/4” O.D.
3
1
5
4
2
7a
Front
COUPLING
NUT
3
3/8 O.D.
BULL-NOSE
RISERS
COMPRESSION
NUT
FERRULE
COLD
CONNECT TO
WASTE OUTLET
3/8 COMPRESSION
CONNECTION
M 9 6 8 7 9 6 R e v. 1 . 1
3
11
INSTALL HANDLES (Lever)
Turn HANDLE STEM (1) to "OFF" position.
Place the HANDLE ADAPTER (2) on the HANDLE STEM (1).
Install the ADAPTER SCREW (3) and tighten securely. Position
LEVER HANDLE (4) and place on ADAPTER (2).
Install the HANDLE SCREW (5) and tighten securely with hex wrench supplied.
5
4
3
2
1
12
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Operate both HANDLES (1) to flush water lines thoroughly.
Rotate TRANSFER VALVE (5) from rim wash to spray several times to check operation.
1
INSTALL HANDLES (Acrylic)
Turn HANDLE STEM (1) to "OFF" position.
Place the ACRYLIC HANDLE (2) on the HANDLE STEM (1).
Install the HANDLE SCREW (3) and tighten securely.
Push in INDEX BUTTON (4).
2
4
3
1
3
5
H
1
13
CHECK DRAIN CONNECTIONS
Pull up POP-UP KNOB (3) and fill Bidet with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Bidet. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.
Push POP-UP KNOB (3) down and check all drain connections and "P" trap for leaks. Tighten if necessary.
2
4
2
SPRAY
14
EverClean™ Finish
Care Instructions
American Standard’s EverClean finish will wipe clean with a soft, dry cloth.
A soft cloth with clean water may also be used, if desired.
No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
15 SERVICE
To change direction of handle rotation, proceed as follows:
Turn VALVE to OFF position.
Loosen HANDLE SCREW (1) .
Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER
SCREW (4) and pull off ADAPTER (3).
Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3) catches on the other FLAT on VALVE STEM (5).
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
Tighten HANDLE SCREW (1).
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.
1
2
4
3
5
M 9 6 8 7 9 6 R e v. 1 . 1
4
SpeedConnect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
Fig. A.
Fig. B.
Fig. C.
DOWN
CAM 1
RE-ATTACH
1
CAM CAP
STOPPER
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
Fig. F.
REMOVE
CAM CAP
M 9 6 8 7 9 6 R e v. 1 . 1
5
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.
LOGO
Fig. G.
LOOP TOWARD
REAR OF BIDET
DRAIN
Locked Mode
(Vandal Proof)
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable .
LOGO
Fig. H.
180˚
LOOP TOWARD
FRONT OF BIDET
DRAIN
Unlocked Mode
Fig. J.
INSTALL CAM
CAM
Fig. K.
INSTALL
CAM CAP
M 9 6 8 7 9 6 R e v. 1 . 1
6
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project