Air Monitoring General Purpose (AVT55) • • • • Protected probe tip Rugged ceramic sensor Wide range of measurement applications Fast response time Windowless (AVT65) Model AVT55 • • • Less flow blockage Ideal for measuring in confined spaces Fast response time AVT55 Omnidirectional (AVT75) AVT65 • • AVT75 • Omnidirectional probe tip Accurate at low velocities from 0.05 to 0.5 m/s (10 to 100 ft/min) Ideal for unknown or varying flow direction Applications Air Velocity Transducers Models AVT55, AVT65, and AVT75 The AVT55, AVT65, and AVT75 Air Velocity Transducers are ideal for both temporary and permanent installations for air velocity measurements in research and development labs, manufacturing processes, and other applications. The full–scale range, signal output, and time constant are user selectable and can be easily changed to meet the needs of your application. • • • • • • • • Accurate. Reliable. Every Time. Comfort and draft studies Critical environment installations (e.g., clean rooms and hospitals) Diffuser design analysis Monitoring drying processes Monitoring air flows in tunnels and subways Used as a standard in wind tunnels and calibration facilities Environmental monitoring in greenhouses and IAQ applications General engineering applications Air Monitoring Air Velocity Transducers Models AVT55, AVT65, AVT75 All models contain on-board electronics and calibration curves that provide a linear signal output. This linear signal is sent out as either a current (mA) or a voltage (V) signal, allowing output to a variety of data loggers or data acquisition systems. In addition, the current and voltage output ranges are user-selectable for your convenience. 6.0 cm (2.35 in) Cable 5.0 m (16.4 ft) Specifications 8.0 cm (3.16 in.) Models AVT55, AVT65, AVT75 Accuracy AVT55 AVT65 AVT75 ±2.0% of reading1, ±0.5% of full scale of selected range ±2.0% of reading1, ±0.5% of full scale of selected range ±3.0% of reading2, ±1.0% of full scale of selected range 12.6 cm (4.95 in) AVT65/75 6.4 mm (.25 in.) Field Selectable Range AVT55 and AVT 65 0.125 m/s to 1.0, 1.25, 1.50, 2.0, 2.5, 3.0, 4.0, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0, 25.0, 30.0, 40.0, 50.0 m/s (25 ft/min to 200, 250, 300, 400, 500, 750, 1,000, 1,250, 1,500, 2,000, 2,500, 3,000, 4,000, 5,000, 7,500, 10,000 ft/min) AVT75 0.05 m/s to 0.5, 0.75, 1.0, 1.25, 1.50, 2.0, 2.5 m/s (10 ft/min to 100, 125, 150, 200, 250, 300, 400, 500 ft/min) Repeatability AVT55 and AVT 65 AVT75 <±1.0% of reading3 N/A Response to Flow AVT55 and AVT 65 AVT75 0.2 sec.4 0.2 sec.5 7.5 cm (3 in.), 15.0 cm (6 in.) 22.5 cm (9 in.), 30.0 cm (12 in.) Resistance Signal Time Constant 0.127 to 50.8 m/s (25 to 0.051 to 2.54 m/s (10 to 10,000 fpm), selectable 500 fpm), selectable Accuracy ±(2% of reading at 18 to ±(3% of reading at 20 to 28°C (64.4-82.4°F) + 26°C ( 68.0-82.4°F) +1% 0.5% of full scale of of full scale of selected selected range) range) Response time Input power Voltage mode: less than 1 ohm, 20 mA max source current Current mode: 500 ohms maximum load Field selectable 0–20 mA, 4–20 mA, 0–5V, 0–10V, 20–10V Field selectable 0.05 to 10 seconds 350 m , 11-30 VDC or 18-28 VAC, A maximum Specifications subject to change without notice. Lancaster Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3QP, England E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] Contact your local AIRFLOW Distributor or visit our website www.airflowinstruments.co.uk for more detailed specifications. P/N 2980566 Rev A Copyright © 2007 by TSI Incorporated 5.0 seconds From 18 to 28°C (64.4 to 82.4°F), outside this range and within temperature compensation range add 0.2% per °C (0.4% per °F). From 20 to 26°C (68 to 78.8°F), outside this range and within temperature compensation range add 0.5% per °C (0.9% per °F). Directed sensitivity of the Model AVT75 is a +5%/-20% of reading +0/-0.05 m/s (+0/-10 ft/min) over 270° solid angle regardless of flow direction. 3 Standard deviation based on one minute average from 0.5 to 5.0 m/s (100 to 1000 fpm). 4 For 63% of final value, tested at 7.5 m/s (1500 fpm). 5 For 63% of final value, tested at 2.5 m/s (500 fpm). 6 Input voltage must be maintained within specifications at the transducer. AIRFLOW Instruments, TSI Instruments Ltd. Tel: +44 149 4 459200 Tel: +33 491 95 21 90 Tel: +49 241 523030 0.2 seconds 2 Probe length 7.5 cm, 15 cm, 22.5 cm, or 30 cm (3 in., 6 in., 9 in., 12 in.) UK France Germany AVT75 Range 1 Input Power 11-30 VDC or 18-38 VAC, 350 mA max6 3.4 cm (1.33 in.) 7.5 cm (3 in.), 15.0 cm (6 in.) 22.5 cm (9 in.), 30.0 cm (12 in.) AVT55/AVT65 Resolution (minimum) 0.07% of selected full scale 3.2 cm (1.25 in.) AVT55 6.4 mm (.25 in.) Temperature Range Compensation 0 to 60°C (32 to 140°F) Operating (electronics) 0 to 93°C (32 to 200°F) Operating (sensor) 0 to 93°C (32 to 200°F) Storage 0 to 93°C (32 to 200°F) Output Impedance 4.6 mm (0.180 in.)
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement