HRPG-150
150W Single Output with PFC Function
series
■
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
..
SPECIFICATION
MODEL
OUTPUT
HRPG-150-3.3 HRPG-150-5
HRPG-150-7.5 HRPG-150-12 HRPG-150-15 HRPG-150-24 HRPG-150-36 HRPG-150-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
30A
26A
20A
13A
10A
6.5A
4.3A
3.3A
CURRENT RANGE
0 ~ 30A
0 ~ 26A
0 ~ 20A
0 ~ 13A
0 ~ 10A
0 ~ 6.5A
0 ~ 4.3A
0 ~ 3.3A
RATED POWER
99W
130W
150W
156W
150W
156W
154.8W
158.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p
120mVp-p
150mVp-p
150mVp-p
200mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
4.3 ~ 5.8V
±2.5%
6.8 ~ 9V
±2.5%
10.2 ~ 13.8V
±1.5%
13.5 ~ 18V
±1.5%
21.6 ~ 28.8V
±1.5%
28.8 ~ 39.6V
±1.5%
40.8 ~ 55.2V
±1.5%
2.8 ~ 3.8V
VOLTAGE TOLERANCE Note.3 ±2.5%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
3000ms, 50ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
87%
88%
88%
16ms/115VAC at full load
VOLTAGE RANGE
Note.5 85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
PROTECTION
FUNCTION
120 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
78.5%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.7A/115VAC
35A/115VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
OVER VOLTAGE
3000ms, 50ms/115VAC at full load
PF>0.99/115VAC at full load
84%
86%
87%
87%
0.9A/230VAC
70A/230VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
41.4 ~ 48.6V
3.96 ~ 4.62V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
5V STANDBY
Shut down o/p voltage, recovers automatically after temperature goes down
5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
REMOTE CONTROL
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
±0.04%/℃ (0 ~ 50℃)
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
NOTE
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
213.4K hrs min.
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.63Kg; 24pcs/16Kg/0.76CUFT
MIL-HDBK-217F (25℃)
℃







File Name:HRPG-150-SPEC 2014-11-25
HRPG-150
150W Single Output with PFC Function
I I
Mechanical Specification
Case No.901I
series
Unit:mm
3.5
7
152.5
1
3
8.2
5
2-M
6
3L
84.5
4
=4
97
65
9.5
2
7
Pin No.
Assignment
4,5
DC OUTPUT -V
6,7
DC OUTPUT +V
CN100
SVR1
.5
ψ3
4.5
78
24
159
Connector Pin No. Assignment (CN100) :
HRS DF11-6DP-2DSA or equivalent
6.5
150
Terminal
18
6-M3(Both Sides) L=6
22
117
fosc :100KHz(3.3~7.5V)
70KHz(12~48V)
Block Diagram
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
38
18.5
10 max.
HRS DF11-**SC
or equivalent
3.5
ψ
HRS DF11-6DS
or equivalent
9
Mating Housing
9
Pin No. Assignment
1
-S
2
+S
3
AUXG
4
AUX
5
RC6
RC+
3.5
Assignment
AC/L
AC/N
FG
28.5
Pin No.
1
2
3
642
531
Terminal Pin No. Assignment
AUX
POWER
RECTIFIERS
&
FILTER
RECTIFIERS
&
PFC
POWER
SWITCHING
RECTIFIERS
&
FILTER
O.T.P.
O.L.P.
AUX
AUXG
+S
+V
-V
-S
DETECTION
CIRCUIT
O.T.P.
FG
PFC
CONTROL
PWM
CONTROL
Derating Curve
O.V.P.
RC+
REMOTE
CONTROL
RC-
Output Derating VS Input Voltage
100
100
Without Cover
90
80
80
70
With Cover
40
LOAD(%)
LOAD (%)
60
The 5V standby must be connected
with a minimum load of 0.03A.
20
-40
-20
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
70
(HORIZONTAL)
60
50
40
85
100
125
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:HRPG-150-SPEC 2014-11-25
HRPG-150
150W Single Output with PFC Function
series
Function Description of CN100
Pin No. Function Description
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
1
-S
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
2
3
4
5
6
+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
Auxiliary voltage output, 4.75~5.25V, referenced to pin 3(AUXG). The maximum load current is 0.3A. This output is not controlled by the
AUX "remote ON/OFF control".
RCRC+
Remote control ground.
Turns the output on and off by electrical or dry contact between pin 5 (RC-). Short: Power OFF, Open: Power ON.
Function Manual
1.Remote Control
The PSU can be turned ON/OFF by using the "Remote
ON/OFF" function
Between RC-(pin5) and RC+(pin6)
Output Status
SW ON (Short)
OFF
SW OFF (Open)
ON
CN100
6
RC+
AUX
5
RC- AUXG
+S
2
-S
1
+S
2
-S
1
SW
-V
-V +V
+V
CN100
642
531
LOAD
-
+
Fig 1.1
2.Remote Sense
The remote sensing compensates voltage drop on the
load wiring up to 0.5V.
-V
-V +V
+V
CN100
642
531
-S
(Pin1)
LOAD
-
+
+S
(Pin2)
Sense lines should
be twisted in pairs
CN100
6
RC+
5
RC- AUXG
AUX
Fig 2.1
File Name:HRPG-150-SPEC 2014-11-25
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising