Description
The Atlas Sound TSD-SEQ6 Sequencer Controller features 6 outputs that are configurable
individually to be either a 24VDC output or Hard Switch Contact Closure (CC). There are two separate
output sequence time delay trimmers ranging from 1 second to 6 minutes. Activation can be done
via the front panel or remotely via Hard Switch CC, Momentary Switch or DC Voltage. The TSD-SEQ6
also incorporates an Emergency Power Down (EPD) port for local fire codes. You can link two
TSD-SEQ6 units together giving you 12 sequenced outputs.
The TSD-SEQ6 is part of a full line of Atlas Sound Time Saving Devices. These compact
(1.5" x 4" x 2.75") units are designed to solve some of the common audio system problems in the
easiest, most efficient, and cost-effective way. All models are made from high quality components
and include removable individual I/O connectors for quick and precise wiring, separate ground
terminals for all I/Os assuring secured connections, and removable level controls that can be
replaced with tamper-resistant security covers. The TSDs are highly efficient and meet most energy
standards as one 24V DC power supply (available separately) can power multiple Atlas Time Saving
Devices.
Features
Interfaceable Atlas Products
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6 Sequenced Outputs
Assignable 24VDC or Hard Switch
Contact Closure (CC) per Output
Sequence 1 is Adjustable: Delay Time
1 Second to 10 Minutes
Sequences 2 - 6 are Adjustable: Delay Time
1 Second to 1 Minute
Remote Activation via 5-24VDC,
Momentary Contacts, Hard Switch Contacts
Status Indicator for Each Output
Emergency Power Down “EPD” Port
Link Out for Two TSD-SEQ6 Controllers
Voltage Output for Remote
LED Status Display
Separate Wiring Port for Each I/O
Cable Management System
Multiple Mounting Configurations
Removable Phoenix Style I/O Connectors
Meets Most Energy Standards
Compact Chassis Design
•
•
•
•
•
•
ECM-20
ECM-20M
ECM-15SH
ECM-20SH
ECM-30
ECM-2063
Installation
•
•
•
•
•
•
Churches
Restaurants
Sports Bars
Schools
Industrial Facilities
House of Worship
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com
–2–
Specifications are subject to change without notice.
TSD-SEQ6
Sequencer Controller
Owner’s Manual
Front Panel Description
6
6
2
3
6
6
4
5
1
1. System Activation Switch - Press to activate the ON or OFF sequence.
2. System Activation Switch Security Cover - If you do not want to use the Front Panel Activation Switch, place the security cover over the switch and secure using the retainer screw.
3. Power LED - Illuminates Blue when 24VDC power is present.
4. System Status/Ready LED - Flashes Green during a sequence and will illuminate steadily when sequence is complete indicating the system is powered up. When the LED is Off, it indicates the system is in the Off mode.
5. Channel Output LED - Each of the 6 outputs have their own LED which illuminates Red when the specific channel / output is active.
6. Bracket Retainer Points - Each TSD includes two mounting brackets for securing the TSD to a
cabinet or wall. Remove screws and align the bracket with the panel hole before firmly tightening the screws.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
–3–
Specifications are subject to change without notice.
AtlasSound.com
TSD-SEQ6
Sequencer Controller
Owner’s Manual
Rear Panel Description
11
11
2
11
11
1
3
4
5
6
7
8
9
10
TSD Input/Output connections are removable for easy system wiring. The connectors have a 3.5mm
pitch between pins.
1. DC Power Input - Each TSD that requires DC power comes with a 2 position connector for an external 24VDC power supply (sold separately). Because of the TSD’s low power consumption, a
single external power supply may power more than one TSD. Please refer to the specifications on current requirements in milliamps to match with the appropriate power supply. Please observe
the polarity of the wiring to this connector. Note: It is acceptable to exceed the current
requirements of the TSDs but NOT safe to use a power supply that is below the current requirement of the device. Use a power supply with a 500mA capacity (Atlas TSD-PS24V500MA).
2. Channel Output - There are 6 channel output control ports. Each output can be assigned to provide a 24VDC output or a Hard Switch Contact Closure (CC). See the Function Settings for Output
configuration below.
3. Remote Activation Momentary Switch Port - Remote System activation can be done several hundred feet away via a momentary contact closure type switch.
4. Remote Activation Hard Switch Contact Closure (CC) Port - Remote System activation can be done several hundred feet away via a Hard Contact closure type switch.
5. Remote Activation 5 - 24VDC Port - Remote System activation can be done several hundred feet away by applying 5 - 24VDC. Only a few milliamps of current is required.
6. Panel LED Port - This port can be used to power an LED on a remote panel for system status indication. The 24VDC Output will pulsate during a sequence and remain at a steady state when the sequence is completed and all outputs are on.
7. Link Control Port - You can combine two TSD-SEQ6 units together to make a 12 step sequence system. Note: Pay special attention to the Input and Output terminals. Connect the Output from
unit 1 (Master) to the Input of unit 2 (Slave). Connect the Output from unit 2 (Slave) to the Input of unit 1 (Master). Pay close attention to this or the Link Out will not work. See the Function Settings for the Master/Slave configuration below.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com
–4–
Specifications are subject to change without notice.
TSD-SEQ6
Sequencer Controller
Owner’s Manual
8. EPD “Emergency Power Down” Port - When an urgent system shut down is required, short the two pins together and the sequence portion will be bypassed and turn Off all outputs at the same time. This EPD feature is commonly used with fire control systems.
9. Delay Pot for Sequence 1 Output - The time between Sequence 1 Output and Sequence 2 Output can be set by rotating the pot following the indicators on the panel. In X1 mode the delay time adjustment is from 1 second to 60 seconds. In X10 mode the delay time adjustment is from
10 seconds to 600 seconds, or 10 minutes. See the Function Settings below for Sequence 1 Output
X1 or X10 configuration.
10.Delay Pot for Sequences 2-6 - The time between Sequence 2 Output and Sequence 6 Output can be set by rotating the pot following the indicators on the panel. Whatever the time is set to will be the time between Sequenced outputs.
11.Cable Management Retainer Points - Use the rear panel screws for connecting the included cable retainers. Each TSD comes with two cable retainers for simplified cable management.
Dip Switch Function Identification
SWITCH FUNCTIONS
Switch Position
• DIP SW # 1-6 - Channel Output Assignment - Each output can be assigned to deliver a Hard Switch Contact Closure (CC) or +24VDC output when activated by the Sequence for Output Channels 1-6.
• DIP SW # 7 - Link Assignment Configuration - This switch determines if the unit is to be a Master or a Slave unit. The Master unit is always the first in line of the sequence.
• DIP SW # 8 - Sequence Output 1 Time Delay - In the X1 setting the adjustable time delay setting is from 1s to 60s and in the X10 position the time delay setting is from 10s to 600s, or 10 minutes.
Mounting
There are three ways to securely mount this TSD:
1.Velcro™ - Each unit includes industrial-grade Velcro™ with adhesive backing to adhere to any
flat surface.
2. Brackets - Each unit includes two mounting brackets to secure to a cabinet or wall.
3. Rack Mount Panel - The optional TSD-RMK rack mount panel supports up to four TSDs in a
1RU space.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
–5–
Specifications are subject to change without notice.
AtlasSound.com
TSD-SEQ6
Sequencer Controller
Owner’s Manual
Specifications
Description
Sequence Controller
Chassis Color
Chassis Material
Black
Aluminum
Outputs
Type
Connection
Qty 6, Sequenced Channel Output, Selectable 24VDC or CC
Removable 3 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, Link Input/Output
Removable 3 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, Output 24VDC for Remote Panel LED Indicator
Removable 2 Position Captive Screw 3.5mm Spacing
Sequence Activation Controls
Type
Qty 1, Momentary Switch Front Panel
Type
Connection
Qty 1, Momentary Switch Port
Removable 2 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, Hard Switch Contact Closure (CC) Port
Removable 2 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, DC Voltage Port
Removable 2 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, Emergency Power Down (EPD)
Removable 2 Position Captive Screw 3.5mm Spacing
Controls
Dip Switch Function
• Output 1-6, Assign 24VDC or Contact Closure (CC)
• Link Assignment
• Sequence Output 1 Time Setting: X1 or X10
Output 1 Sequence Delay
Trim Pot, 1 sec - 60 sec or 10 sec - 10 min (Selectable)
Output 2 - 6 Sequence Delay
Trim Pot, 1 sec - 60 sec
Indicators
Sequence Status
Output Sequence Status
Power
Green, Qty 1
Red, Qty 6
Blue
Mounting
Velcro™
Brackets
TSD-RMK
Cable Retainer
Industrial-Grade, Included
Qty 2, Included
Optional 1 RU Rack Mount Panel (Supports 4 TSD Units)
Qty 2, Included
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com
–6–
Specifications are subject to change without notice.
TSD-SEQ6
Sequencer Controller
Owner’s Manual
Power Requirements
Voltage
Power Consumption Current Power Consumption VA Watts
24VDC, 500mA
100mA
2.4W
Dimensions
H 1.5" (39mm) x W 4" (101mm) x D 2.75" (70mm)
Weight
6oz, .165kg
Accessories
TSD 24VDC Power Supplies
TSD-RMK 1 RU Rack Panel
Safety and Certifications
External Power Supply
cUL, CE, RoHS, TUV
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
–7–
Specifications are subject to change without notice.
AtlasSound.com
TSD-SEQ6
Sequencer Controller
Owner’s Manual
Limited Warranty
All products manufactured by Atlas Sound are warranted to the original dealer/installer, industrial or
commercial purchaser to be free from defects in material and workmanship and to be in compliance
with our published specifications, if any. This warranty shall extend from the date of purchase for
a period of three years on all Atlas Sound products, including SOUNDOLIER brand, and ATLAS
SOUND brand products except as follows: one year on electronics and control systems; one year on
replacement parts; and one year on Musician Series stands and related accessories. Additionally,
fuses and lamps carry no warranty. Atlas Sound will solely at its discretion, replace at no charge or
repair free of charge defective parts or products when the product has been applied and used in
accordance with our published operation and installation instructions. We will not be responsible
for defects caused by improper storage, misuse (including failure to provide reasonable and
necessary maintenance), accident, abnormal atmospheres, water immersion, lightning discharge,
or malfunctions when products have been modified or operated in excess of rated power, altered,
serviced or installed in other than a workman like manner. The original sales invoice should be
retained as evidence of purchase under the terms of this warranty. All warranty returns must comply
with our returns policy set forth below. When products returned to Atlas Sound do not qualify for
repair or replacement under our warranty, repairs may be performed at prevailing costs for material
and labor unless there is included with the returned product(s) a written request for an estimate
of repair costs before any nonwarranty work is performed. In the event of replacement or upon
completion of repairs, return shipment will be made with the transportation charges collect.
EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL
DAMAGES FOR PERSONAL INJURY, ATLAS SOUND SHALL NOT BE LIABLE IN TORT OR CONTRACT
FOR ANY DIRECT, CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE
INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS. THE ABOVE WARRANTY IS IN LIEU OF
ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
Atlas Sound does not assume, or does it authorize any other person to assume or extend on its
behalf, any other warranty, obligation, or liability. This warranty gives you specific legal rights and
you may have other rights which vary from state to state.
Service
Should your Atlas TSD require service, please contact the Atlas Sound
warranty department at 1-877-689-8055, ext. 1274 to obtain an RA number.
Atlas Sound Tech Support can be reached at 1-800-876-3333.
Visit our website at www.AtlasSound.com to see other Atlas products
©2011 Atlas Sound L.P. All rights reserved. Atlas Sound is a trademark of Atlas Sound L.P. All other trademarks are the property of their respective owners. ATS004115 RevB 1/12
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com
–8–
Specifications are subject to change without notice.
Download PDF

advertising