ATTO Technology FC2600 Network Card Installation and Operation Manual

Add to my manuals
17 Pages

advertisement

ATTO Technology FC2600 Network Card Installation and Operation Manual | Manualzz

ATTO Technology, Inc.

Installation and Operation Manual

ATTO ExpressPCI FCSW

64-bit PCI-to-1-Gigabit FC Host Adapter, SW optical SC interface

ATTO ExpressPCI FC 2600

64-bit PCI-to-1-Gigabit FC Host Adapter, HSSDC interface

© 2003 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.

10/2003 Document Control Number: PRMA-0259-000MD

Contents

1 ATTO ExpressPCI provides Fibre Channel solutions 1

Advanced SCSI support

PCI features

Environmental, physical specifications

2 Fibre Channel is a key technology for storage ........ 3

Glossary

3 Hardware installation and initial configuration ........ 5

System requirements

Fibre Channel address

Installation

Cabling

Initial configuration

4 Installing/updating device drivers and firmware ..... 7

Windows 2000/XP driver installation

Windows NT driver installation

Mac OS X driver installation/update

Re-flashing firmware

Linux and Sun Solaris driver installation

5 Troubleshooting ......................................................... 9

General suggestions

Windows 2000/XP

Windows NT

Macintosh

Appendix A Standards and compliances .................... i

Appendix B Fibre Channel accessories ...................... ii

Appendix C SCSI host adapter selection guide .......... iii

Appendix D Contact ATTO Technology, Inc. .............. iv

1 ATTO ExpressPCI provides Fibre Channel solutions

All ATTO ExpressPCI models have been designed to ensure interoperability with Fibre Channel devices and compatibility with a broad range of servers and workstations to meet your needs.

The ATTO ExpressPCI FCSW and ATTO

ExpressPCI 2600 host adapters offer high performance for your applications. Each conforms to a strict interpretation of Fibre

Channel specifications to ensure the adapter will work with a variety of other SAN (Storage Area

Network) components.

The ExpressPCI FCSW is a 64-bit PCI-to-Fibre

Channel host adapter with a fixed short wave optical Fibre Channel interface.

The ExpressPCI 2600 is a 64-bit PCI-to-Fibre

Channel host adapter with a fixed copper HSSDC interface.

Strict adherence to ANSI FC-AL-2, FC-

PLDA, FC-Tape and FC-FLA specifications

1.0625-Gigabit data transfer rates, providing up to 200 MB/sec. throughput in full duplex mode

Support for Class 2 and Class 3 transfers

Point-to-point, arbitrated loop and direct fabric/switch attach topologies support

ASPI and SCSI Manager 4.3 compatible

Multiple initiator support

LEDs for online and fault status

Windows

®

XP/2000/NT; Windows

95/98; Linux, Sun

®

Solaris and

Macintosh® OS, OS X

RAID kits available

SNIA Fibre Channel host adapter API support

Advanced SCSI support

Exclusive Advanced Data Streaming

(ADS

TM

) Technology support

SCSI-FCP over Fibre Channel support

SCSI-3 tagged command queuing

Large command FIFO

Disconnect/reconnect support

Asynchronous I/O support

Bootable from attached disks

Accelerated PCI bus management

PCI 2.2 and PCI 99 compliant

PCI BusMaster rate of 528 MB/sec. in

64-bit/66 MHz PCI slots

66MHz/64-bit PCI compatible.

Backward compatible to 33MHz and 32bit PCI

Environmental and physical specifications

Temperature: 0-50° C

Humidity: 10-90% non-condensing

Short Card Form Factor

Length: 6.521”

Height: 4.2”

MTBF: 150,000 hours

MTTR: <15 minutes

Power Requirements 1 Amp @ 5 Volts

1

ATTO Technology ExpressPCI FC 3321 Installation and Operation Manual

Fibre Channel ports

FC 3342

4

FC 3322

2

2-Gigabit Adapters

FC 3321

2

FC 3300

1

Optical interface SW, LC, SFP SW, LC, SFP SW, LC, SFF Fixed SW LC

Copper interface

400 MB/sec Max. transfer rate 400 MB/sec per channel

Class transfers

Full duplex

66/33 MHz PCI compatible

2, 3

7

66 MHz only

133 MHz PCI-X compatible

7

64-bit only

64- and 32-bit PCI compatible

Windows

®

XP/2000/NT

Windows Server 2003

7

7

Solaris/Linux

400 MB/sec per channel

2, 3

7

7

7

7

7

7

Linux

400 MB/sec per channel

2, 3

7

7

7

7

7

Linux

2, 3

7

7

7

Mac OS X

Mac OS 9

RAID support

Maximum cable length 300m @ 2-Gb

500m @ 1-Gb

300m @ 2-Gb

500m @ 1-Gb

Mac OSX

Mac OSX

300m @ 2-Gb

500m @ 1-Gb

7

7

7

7

7

7

300m @ 2-Gb

500m @ 1-Gb

FC 3305

1

HSSDC

400 MB/sec

2, 3

7

7

7

7

7

7

7

7

7

25 m

(175m with

MIA)

2

2 Fibre Channel is a key technology for storage

Fibre Channel is a serial communications technology designed to transfer large amounts of data among a variety of hardware systems over long distances. It is a key technology for applications that require shared, high bandwidth access to storage.

Fibre Channel provides a logical, point-to-point, serial channel for the transfer of data between a buffer at a source device and a buffer at a destination device. It moves buffer contents from one port to another, without regard to the format or meaning of the data so different upper level protocols are able to run over Fibre Channel hardware.

The Fibre Channel architecture is structured as a hierarchical set of protocol layers. Defined within these layers are rules for signal interfaces, serial encoding and decoding, error control, frame format and communications protocols.

ATTO ExpressPCI Fibre Channel host adapters carry SCSI protocol over Fibre Channel.

Glossary

______________________________________________________________________________________

Some terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology website

(www.attotech.com), the Fibre Channel Industry Association

(www.fibrechannel.com), Cern (www.cern.ch), the Storage Area Networking Industry Association

(www.snia.org), and the Fibre Channel Consortium (www.iol.unh.edu/consortiums, click on FC).

Term

ANSI arbitrate arbitrated loop

Definition

American National Standards Institute process of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop at the same time a loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can communicate at one time; low-cost solution which may or may not use hubs and switches auto negotiation hardware senses and automatically responds depending on configuration

BER Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent bit bus

Smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1 a collection of unbroken signal lines used to transmit information from one part of a computer system to another; taps on the lines connect devices to the bus

Byte channel

CPU

CRC an ordered set of 8 bits a point-to-point link which transports data from one point to another

Central Processing Unit: the portion of the computer that actually performs computations

Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received and transmitted data; if no error has occurred during transmission, the CRC for both received and transmitted data should be the same destination address a value in the frame header of each frame which identifies the port in the node where the frame is being sent a program that allows a microprocessor to direct the operation of a peripheral device device driver

DMA Direct Memory Access: a way to move data from a storage device directly to RAM without using the CPU’s resources

DMA bus master Allows a peripheral to control the flow of data to and from system memory by block as opposed to allowing the processor to control the data by bytes (PIO or programmed I/O)

3 ATTO Technology ExpressPCI FCSW and FC 2600 Installation and Operation Manual

Term

fabric

FC

F_port

FL_port frame frame header full duplex half duplex host initiator device

L_port

LED

Definition

A Fibre Channel switch or two or more Fibre Channel switches interconnected to physically transmit data between any two N_Ports on the switch or switches

Fibre Channel

A port in the Fibre Channel fabric where a N_port may attach

A port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop an indivisible unit for transfer of information in Fibre Channel the first field in the frame containing the address and other control information about the frame a communication protocol which allows transmission in both directions at the same time a communication protocol which allows transmission in both directions, but only one direction at a time a processor, usually a CPU and memory, which communicates with devices over an interface

A component which originates a command a port in an arbitrated loop, either a NL_port or a FL_port

Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs are used as indicator lights on all sorts of electronic devices

LUN Logical Unit Number: an identifier for a logical unit (0-7) multi-mode fiber an optical fiber which can carry several beams of light at once

N_port

NL_ port a port attached to a node used with point to point or fabric configurations a port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration originator an initiating device; a component which originates a command parity checking A method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error message occurs if the sum is not correct

PCI Peripheral Component Interconnect. Allows peripherals to be connected directly to computer memory, bypassing the slower ISA and EISA busses point-to-point port port address a topology where two ports communicate an access point in a device: see N_port, NL_port, etc.

also port number; the address, assigned by the PCI bus, through which commands are sent to a host adapter board port number receiver see port address the ultimate destination of data transmission; a terminal device scatter/gather

SCSI a device driver feature which allows the host adapter to modify a transfer data pointer so that a single host adapter can access many segments of memory, minimizing interrupts and transfer overhead

Small Computer Systems Interface: a processor-independent standard for system-level interface between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers, scanners, etc. single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is nearly equal to the wavelength of the source topology transceiver transfer rate logical layout of the parts of a computer system or network and their interconnections a transmitter/receiver module the rate at which bytes or bits are transferred, as in megabytes or gigabits per second

4

3 Hardware installation and initial configuration

You will need a basic understanding of Fibre Channel before installing the ATTO ExpressPCI host adapter. Please refer to Chapter 2 for a list of Fibre Channel-related web sites.

WARNING Remember to back up your system data before changing or installing hardware.

System requirements

The ATTO Express PCI host adapter package contains the host adapter, the ATTO Express Pro-

Tools CD and a warranty and registration card. If any of these items are missing, contact your authorized ATTO Technology representative.

To install and use the ATTO ExpressPCI Fibre

Channel adapter you will need:

A computer with an available 32- or 64-bit

PCI expansion slot.

The complete ATTO ExpressPCI FC host adapter package.

Fibre Channel address

ATTO ExpressPCI host adapters are configured with a unique address designated by the Institute of Electrical and Electronic Engineers (IEEE).

The WorldWide Port Name (WWN) and Node name are the two components of the address assigned to Fibre Channel products. This address, which is stored in the flash ROM on the ATTO

ExpressPCI host adapter, allows the system to recognize it as a unique part of your configuration. The address is clearly marked on the back of the board for easy identification.

Please keep a reference copy of the number in a safe place or write in the space provided below.

WWN:_______________________

Installation

WARNING ATTO ExpressPCI host adapters contain components that are sensitive to electrostatic discharge

(ESD). ESD can cause damage to the ExpressPCI host adapter. Please follow standard methods to avoid ESD.

1 Power down the computer and unplug the computer from all power sources.

2 Open the case.

3

Ins tall the ATTO ExpressPCI host adapter in any open PCI expansion slot. If you have questions about how to install an expansion card in your system, consult your computer’s documentation.

If you have difficulty seating the ATTO ExpressPCI host adapter in 32-bit PCI bus computers, check to make sure the connector can accommodate 64-bit host adapters.

4 Connect Fibre Channel devices by attaching a Fibre Channel cable to the connector on the ATTO ExpressPCI host adapter. Refer to

Exhibit 3-1 when selecting cables and connectors.

The ATTO ExpressPCI FCSW has an embedded duplex SC optical connector and uses a short wave laser. A multimode cable must be used with short

wave lasers. See Exhibit 3-1 for cable type and

maximum distances.

5 Close the computer case and power it up.

Cabling

Fibre Channel technology offers a variety of cabling options including standard copper, equalized copper, and fiber optic depending on the requirements of your environment. See

Exhibit 3-1 for cable type and maximum

distances.

5 ATTO Technology ExpressPCI FCSW and FC 2600 Installation and Operation Manual

Exhibit 3-1 Required connectors and recommended cables

host adapter cable length cable type

ExpressPCI FCSW up to 500 meters multimode

ExpressPCI FC 2600 < 15 meters

15-25 meters unequalized copper equalized copper

cable size connector

50 micron duplex SC optical

HSSDC

HSSDC

Initial configuration

ATTO ExpressPCI host adapters come preconfigured to operate properly in a variety of common system setups. However, some systems or setups may benefit by tuning the adapter for optimal performance.

ATTO Technology provides a variety of utilities for adapter configuration as described in the

ATTO ExpressPCI Utilities Installation and

Operation Manual.

Windows ATTO ExpressPCI Configuration Tool or

BIOS utilities (CTRL_F at boot)

Mac OS ATTO Express Pro-Tools

Mac OS X ATTO ExpressPCI Configuration Tool

6

4 Installing/updating device drivers and firmware

ExpressPCI FC host adapters require device drivers and firmware for proper operation. Your adapter firmware was properly flashed before shipment, but the firmware may need to be updated as new versions become available, or if the factory-installed version becomes corrupt. Visit the ATTO website, www.attotech.com, to download the latest drivers and firmware.

ATTO recommends using the same device driver and firmware version. To verify the version:

Windows

Use the ATTO ExpressPCI

Configuration Tool for complete information about the driver and firmware version or use a combination of the adapter boot string (firmware version) during system boot and the Device

Manager (driver version)

Mac OS X

Use the ATTO ExpressPCI

Configuration Tool (driver and firmware version available) or Apple System Profiler (driver version only)

Windows 2000/XP driver installation

New installation

1

After initial devices have been loaded, the installer will prompt the user to Specify

Additional Device by using the S option.

2

When prompted for vendor’s disk, insert the

ATTO ExpressPro-Tools CD-ROM, into the drive

and press the ENTER key.

3

Select ExpressPCI FC and then press the ENTER

key.

4

Continue the installation of the operating system. The Windows 2000 installation may request the ExpressPCI driver disk again.

5

Reboot the system.

Pre-existing installation

1

Boot into Windows 2000/XP. The New Hardware

Wizard window will appear.

2

Click Next.

3

Choose the Search for a suitable driver for my

device option.

4

Insert the ATTO ExpressPro-Tools CD.

5

In next window, be sure the CD-ROM is selected as the source for the driver.

6

Once the system finds the driver, click the Next

button.

7

Click Yes when the system prompts to continue

installation.

8

Reboot system.

Updating the Windows 2000 driver

1

Right-click My Computer and select Properties.

2

Select the Hardware tab and select Device

Manager.

3

Right-click the ATTO ExpressPCI adapter

description, located under SCSI and RAID

controllers, and select Properties.

4

Go to the Driver tab and select Update Driver.

5

Select Next.

6

Choose the Search for a suitable driver for my

device option.

7

Choose the appropriate path to the new driver location.

8

Once the system finds the driver, click the Next

button.

9

Click Yes when the system prompts to continue

installation.

10

Reboot system

Windows NT driver installation

New installation

1

Begin the Windows NT installation using the

Windows NT Installation floppy diskettes.

2

During the installation after initial devices have been loaded, the installer will prompt you to

Specify Additional Devices by using the S option.

3

When prompted for vendor’s disk, insert the

ATTO ExpressPro-Tools CD-ROM into the drive

and press the ENTER key.

4

Select ExpressPCI FC and then press the ENTER

key.

5

Continue the installation of the operating system. The Windows NT installation may request the Express FC driver disk again.

Pre-existing installation

1

Enter the Control Panel on the Start Menu under

Settings.

2

Locate and double click on the SCSI Adapter icon

3

Click on the Drivers tab and then the Add button.

4

When the Install Driver screen appears, select

Have Disk.

5

Place the ATTO ExpressPro-Tools CD-ROM into the drive

6

Change the path in the Copy Manufacturers files

from to the appropriate drive.

7

Select ExpressPCI FC and click OK.

8

When the driver is finished loading, reboot the system.

7 ATTO Technology ExpressPCI FCSW and FC 2600 Installation and Operation Manual

Updating the Windows NT driver

1

Click on the Start menu and select Run.

2

Type in RDISK.EXE and press ENTER to create

an emergency repair disk.

3

Double-click My Computer and open the Control

Panel.

4

Double-click the SCSI Adapter icon.

5

Click on the Driver tab and highlight the ATTO

ExpressFC driver.

Mac OS X driver installation/update

New or previous installation

1

Download the appropriate version of the device driver from the ATTO web site at

www.attotech.com.

2

Extract the file to your desktop.

3

Double click the installer icon and follow the on screen prompts

Re-flashing firmware

To re-flash firmware in Windows or Mac OS X using the ATTO ExpressPCI Configuration

Tool:

1

Download the most recent version of the

Configuration Tool from the ATTO web site at

www.attotech.com.

2

Download the proper flash bundle (these are adapter specific) from the ATTO web site

3

Extract these files to your desktop and install the

Configuration Tool on your system.

4

Launch the Configuration Tool.

5

In the Device window, select the adapter that

needs to be updated.

6

In the Flash window, click on the Browse button to

find the flash bundle that you previously downloaded to your desktop.

7

Click Update to update your flash

8

Reboot your system for the firmware changes to take effect

9

Refer to the ExpressPCI Utilities Operation and

Installation Manual for additional information on using the Configuration Tool

6

Click on the Remove button to remove the old

driver.

7

Click on the Add button and select Have Disk.

8

Insert the ATTO ExpressPro-Tools CD-ROM.

9

Enter the appropriate path to the drive

10

If prompted, select a New installation of the

driver. Do not select Current installation.

11

Reboot your system.

4

Reboot your system for the changes to take effect.

5

Current device driver version can be verified using the ATTO ExpressPCI Configuration Tool.

Refer to the ExpressPCI Utilities Operation and

Installation Manual for additional information.

To re-flash firmware on a PC using the BIOS utilities:

1

Obtain the latest firmware from the ATTO web

site www.attotech.com and extract it to a floppy

disk by executing the self-extracting file.

2

Reboot the PC.

3

During the reboot process, an ATTO Technology banner will announce that the host adapter was

detected. Enter Control-F when prompted to

begin the set-up utility. This must be done within a few seconds after the banner appears, or you will not be able to enter the utility. If this happens, simply repeat step 3.

4

In the utility, select the Upgrade Flash ROM option

and insert the disk into the drive slot.

5

Follow the on-screen instructions.

6

Remove the disk and reboot your system for the firmware changes to take effect

Note: Firmware must be loaded from a floppy or from the internal hard drive because the

CD-ROM drivers are not loaded at this point in the system boot process.

Linux and Sun Solaris driver installation

ATTO offers Linux and Sun Solaris drivers which are compatible with ExpressPCI host adapters. A complete download package, including all necessary installation instructions, is available on the ExpressPro-Tools CD-ROM or directly from the ATTO web site. Please refer to these documents for installation instructions.

8

5 Troubleshooting

This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology web site (www.attotech.com) or contact an

ATTO Technology authorized representative.

General suggestions

Check each cable connection on every device. Verify all cables are in proper working condition. Loose or broken cables are often the cause of errors or problems.

Check that your Fibre Channel devices are plugged into an AC outlet and are turned on before you add power to your computer.

If using an MIA, check to see it is operating properly.

Windows 2000/XP

If using an Intel-based PC, Fibre Channel drives should be booted up before the host computer. If the PC is powered up before the drives, the drives may not be visible to

Windows.

If the devices connected to the ATTO

ExpressPCI host adapter are not accessible:

1

Right-click My Computer and select

Properties.

2

Select the Hardware tab and select Device

Manager.

3 If the ATTO ExpressPCI host adapter does not appear under the SCSI and RAID controllers, shut down and make sure the

ATTO ExpressPCI host adapter is properly seated in the PCI slot (remove power from the PC, remove its case, check the PCI slot, replace the case, apply power).

4 Reload the driver.

5 If the adapter has been identified but there is an exclamation point (!) on the listing, right

click on the listing and select Uninstall.

Reboot system and repeat the installation process. If problems persist, contact your authorized ATTO Technology representative.

If the card has been recently re-flashed with new firmware, the new Windows driver must be installed. Follow the procedure in

Chapter 4.

All of the external devices connected to the host adapter should be identified. If they do not appear in the Device Manager, the external devices or connection may not be working properly.

For Intel-based PCs, check the computer

CMOS setup and verify that the PCI slots are configured correctly. Procedures vary greatly: refer to the manual supplied with your system or call the computer supplier for configuration assistance. Windows

2000 is a Plug-n-Play OS: be sure your computer’s BIOS is set accordingly.

If these do not solve the problem, re-flash the host adapter and re-install the Windows

2000 driver.

Windows NT

If using an Intel-based PC, Fibre Channel drives should be booted up before the host computer. If the PC is powered up before the drives, the drives may not be visible to

Windows NT.

If the devices connected to ATTO ExpressPCI host adapter are not accessible:

1

Open the SCSI Adapters utility in the Control

Panel under Settings.

2 Verify the ATTO ExpressPCI host adapter

64-bit PCI Fibre Channel host adapter

appears under the Devices List.

3

If it does not appear in the Device List, verify

that the adapter is seated properly in the PCI slot (remove power from the PC, remove its case, check the PCI slot, replace the case, apply power).

9 ATTO Technology ExpressPCI FCSW and FC 2600 Installation and Operation Manual

4

If it has been identified, click on the Drivers

Tab to see if the ATTO ExpressPCI host

adapter driver has been started. It will say

Started in the right hand column of the

window. If the ATTO ExpressPCI host adapter driver appears but is not started,

check on the device status. In the Control

Panel click on Devices and scroll down to

expresfc. Click Startup button. Startup type

should be Boot. Click on Hardware profiles,

status should be Enabled.

5

If ExpressPCI FC does not appear in the

Device List, try reloading the driver software as described in Chapter 4 of this manual.

6

If it is started, go back to the Devices tab of

the SCSI adapters utility window and double click on the ATTO ExpressPCI host adapter description, and then on the bus it is assigned to. All of the external devices connected in the loop should be identified.

If they do not appear in the Device List, the

external devices or connection are not working properly.

If the card has been recently re-flashed with new firmware, the new NT driver must be installed.

For Intel-based PCs, check the computer

CMOS setup and verify that the PCI slots are configured correctly. Procedures vary greatly: refer to the manual supplied with your system or call the computer supplier for configuration assistance.

If these suggestions do not solve the problem, re-flash the host adapter and reinstall the Windows NT driver.

Macintosh

Power up Fibre Channel drives before booting up your machine. If the Macintosh host is powered up before the drives, the drives may not automatically mount

(depending on when the drives were powered on).

Re-flash the card using the updater program

(See Chapter 4). Select the unconditional flash option when attempting to re-flash the host adapter.

10

Appendix A Standards and compliances

The equipment described in this manual generates and uses radio frequency energy. The Technical

Specification sheet for a particular ATTO ExpressPCI host bus adapter list certifications for that model.

FCC Standards: Radio and Television Interference

______

WARNING This equipment has been tested and found to comply with the limits for a

Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Y

Reorient or relocate the receiving antenna

Y

Increase the separation between the equipment and receiver

Y

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

Y

Consult the dealer or an experienced radio/TV technician for help

Canadian Standards

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numerique to la Classe B est conforme a la norme NMB-003 du Canada.

European Standards

Declaration of Conformity

This following statement applies to the ATTO Express PCI host bus adapter.

This device has been tested in the basic operating configuration and found to be compliant with the following European Union standards:

Application of Council Directive: 89/336/EEC

Standard(s) to which conformity is declared: EN55024:1998

This Declaration will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant.

Usage Restrictions

The use of optical instruments with this product will increase eye hazard.

The multimode transceiver (ATTO Express PCI FCSW only) is a Class 1 laser product complying with

IEC 825-1 and FDA-21 CFR 1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum ratings. The laser is non-OFC compliant as it is a Class 1 device.

The optical ports of the modules must be terminated with an optical connector or with a dust plug.

Failure to adhere to the above restrictions could result in a modification that is considered an act of

“manufacturing” and will require, under law, recertification of the modified product with the U.S. Food and Drug Administration (ref. 21 CFR 1040.10(i)).

i ATTO Technology ExpressPCI FCSW and FC 2600 Installation and Operation Manual

Appendix B Fibre Channel accessories

The following Fibre Channel accessories are available through ATTO Technology and authorized resellers. Contact an ATTO Technology authorized sales representative to order.

Copper Cables

CBL-HSDB-03X

CBL-HSDB-10X

CBL-HSHS-03X

CBL-HSHS-10X

CBL-FCCU-003

CBL-FCCU-010

CBL-FCCE-020

HSSDC to DB9 Copper Fibre Channel Cable – 3m.

HSSDC to DB9 Copper Fibre Channel Cable – 10m.

HSSDC to HSSDC Copper Fibre Channel Cable – 3m.

HSSDC to HSSDC Copper Fibre Channel Cable – 10m.

DB9 Copper Fibre Channel Cable (Unequalized) – 3m.

DB9 Copper Fibre Channel Cable (Unequalized) – 10m.

DB9 Copper Fibre Channel Cable (Equalized) – 20m.

Optical Cables

CBL-FCFI-05x

CBL-LCSC-003

CBL-LCSC-010

5 m. cable– Duplex 50 Micron Multi-mode FC/Optical

3 m. 50/125 optical cable (LC to SC)

10 m. 50/125 optical cable (LC to SC)

MIA

ADAP-MIAS-BLK Media Interface Adapter (MIA) Short Wave

A variety of Fibre Channel and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information.

Fibre Channel solutions

FC Rack System

ATTO FibreBridge

TM

ATTO FibreCenter

TM

Modular Fibre Channel rack

Fibre Channel to SCSI bridge

Fibre Channel Hub

ATTO ExpressPCI FCSW 1-Gigabit Fibre Channel Host Adapter

ATTO ExpressPCI FC 2600 1-Gigabit Fibre Channel Host Adapter

ATTO ExpressPCI FC 3300 2-Gigabit Fibre Channel Host Adapter

ATTO ExpressPCI FC 3305 2-Gigabit Fibre Channel Host Adapter

ATTO ExpressPCI FC 3321 2-Gigabit Fibre Channel Host Adapter, Dual Channel

SCSI solutions

ATTO ExpressPCI Family of SCSI Host Adapters

Software

ATTO AcelWare

ATTO ExpressRAID

SAN (Storage Area Network) volume management

Creates RAID groups across storage in networks

ATTO ExpressPro-Tools Configuration and management software

ATTO ExpressStripe for OSX MacOSX RAID and benchmark software

ii

Appendix C SCSI host adapter selection guide

ATTO Technology offers a number of SCSI and Fibre Channel solutions for storage. The following chart compares the features of ExpressPCI SCSI host adapters.

Supported platforms: Sun Solaris; Linux; NetWare; SCO Unix; Windows 2000, 95/98, NT, and Macintosh

OS and OS X.

Complete RAID packages are also available and include an ExpressPCI SCSI host adapter, ExpressRAID software and appropriate cable(s). Add "-KIT" suffix to host adapter product code (i.e. EPCI-UL3D-KIT)

Specific features

Single Channel

Max. transfer rate

LVD

HVD

64-bit

32-bit

33/66 MHZ

133 MHZ

Bus ID support

Part number

Express PCI Ultra 320

320 MB/sec.

7

7

7

7

7

30

EPCI-UL4S

Express PCI Ultra 3

160 MB/sec.

7

7

7

7

30

EPCI-UL3S

Express PCI Ultra Wide

40 MB/sec.

7

15

EPCI-PSC

Dual Channel--- 2 independent channels

Max. transfer rate

LVD

64-bit

32-bit

33/66 MHZ

133 MHZ

Bus ID support

Part number

ExpressPCI Ultra 320

640 MB/sec

7

7

7

7

7

30

EPCI-UL4D

Express PCI Ultra 3

320 MB/sec.

7

7

7

7

30

EPCI-UL3D

iii

Appendix D Contact ATTO Technology, Inc.

Customer service, sales information and technical support are available by phone Monday through Friday,

Eastern Standard Time 8:00 a.m. to 8:00 p.m., or by e-mail and web site 24-hours a day.

ATTO Technology, Inc.

155 CrossPoint Parkway

Amherst, New York 14068

(716) 691-1999 • voice

(716) 691-9353 • fax http://www.attotech.com

ATTO Technology can also be reached via e-mail at the following addresses:

Sales Support:

Technical Support: [email protected]

[email protected]

iv

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project