Cres Cor 130 Operation Manual
Advertisement
Advertisement
Proof/Hot Cabinets
Rev. 3 (6/05)
FL-2309
Page 1 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 130 and 131 “D” Series Hot Cabinets
Model No.
1301836D
131UA11D
131UA9D
1301836D208
131UA11D208
131UA9D208
1301836D240
131UA11D240
131UA9D240
Volts
120
208
240
Watts
1920
2000
2000
All are designed for AC service.
Amps
16.6
9.6
8.6
Hertz
60
60
60
Phase
1
1
1
NEMA
5-20P
6-15P
6-15P
CONTROL PANEL PARTS IDENTIFICATION
1. Power Switch
2. Yellow Light-Power
3. Thermostat
4. Thermometer
HOW TO INSTALL UNIT:
1.
2.
Place cabinet near warm ovens. Do NOT put in drafty areas or near ventilating systems.
Plug cord end into proper wall outlet.
NOTE: No. 8 setting = approx. 175°F (79°C)
No.6 setting = approx. 165°F (74°C)
Proper food holing temperature is 140°F (60°C) or higher. The thermometer shows the temperature inside.
2.
3.
4.
5.
HOW TO START UNIT:
1.
Turn the POWER switch on. The yellow light will turn on.
Turn thermostat to #10.
Preheat cabinet for 30 minutes.
Put food into cabinet.
Turn thermostat to #8 and close door.
1.
2.
3.
TO TURN OFF UNIT:
Turn thermostat off.
Turn the POWER switch off.
The yellow light will go out.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Proof/Hot Cabinets
Rev. 3 (6/05)
FL-2309
Page 2 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 130 and 131 “D” Series Hot Cabinets
MAINTENANCE
HOT UNIT REMOVAL INSTRUCTIONS
:
1.
2.
3.
Unplug power cord from wall outlet.
Remove screw from back of cabinet located just above cord. (For Model 1301836D ONLY).
Pull entire unit out the front of the cabinet.
HOW TO CLEAN THE CABINET:
BEFORE cleaning the cabinet:
1.
2.
3.
Allow cabinet to cool.
Remove Hot unit from cabinet.
Do NOT use abrasives or harsh chemicals.
Cleaning Notes:
1.
Wipe up spills as soon as possible.
2.
Clean cabinet regularly to avoid heavy dirt build-up.
3.
4.
5.
Make a test spot with cleaner.
Follow manufacturer’s directions on cleaner.
Do not mix cleaners.
6.
Avoid drips and splashes.
HOW TO CLEAN THE UNIT:
DOOR and
CABINET
Inside and
Outside
(Aluminum)
SOIL CLEANER
Mild detergent* and hot water, or mild abrasive cleaner.
METHOD
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
DIRT
Steam (no strong alkaline additive)
1. Rinse after steam cleaning.
2. Wipe dry.
FINGERPRINTS,
GREASE OIL
Chemical oven cleaner for aluminum.
Mild abrasive cleaner; oily or waxy cleaner.
Follow oven cleaner manufacturer’s directions.
Apply with soft, clean cloth.
1. Wipe with damp cloth.
WATER SPOTS Mild abrasive cleaner.
2. Rinse and dry.
* Mild detergents include soaps and non-abrasive cleaners
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Proof/Hot Cabinets
Rev. 3 (6/05)
FL-2309
Page 3 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 130 and 131 “D” Series Hot Cabinets
TROUBLE-SHOOTING CHART:
FAILURE
1. Yellow light at switch does NOT light
2. Unit does not heat.
3. Unit gets too hot or won’t shut off.
POSSIBLE CAUSE
1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet.
1c. Switch is “OFF”.
2a. Thermostat set too low or is “OFF”.
2b. Switch is “OFF”.
3a. Defective electrical parts. UNPLUG UNIT
FROM WALL OUTLET.
4a. Defective blower.
4. Blower does not work or make noise.
NOTE: Optional digital thermometer will fl ash if cabinet temperature is below 140°F or above 250°F.
Call the factory if you need different settings.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
REPLACEMENT PARTS:
DESCRIPTION
Hot Unit, Model 131 Series
Hot Unit, Model 1301836D
Blower Kit
Heater Kit
Thermostat Kit
Thermometer Kit (Analog)
Power Cord
Power Switch
Pilot Light
CABINET
Door Latch
Door Hinge
Pan Slides
120 VOLT
HU1254052
HU1254055
0769-005-K
0811-022-K
0848-062-K
5238-030-K
0810-065-1
0808-116
0766-094
1301836D
1136-043-K
0519-105
N/A
208 VOLT
HU1254053
HU1254056
0769-006-K1
0811-185-K
0848-062-K
5238-030-K
0810-039
0808-116
0766-095
240 VOLT
HU1254054
HU1254057
0769-006-K1
0811-023-K
0848-062-K
5238-030-K
0810-039
0808-116
0766-095
131UA SERIES
1006-154-01
0519-104
0621-181
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Proof/Hot Cabinets
Rev. 3 (6/05)
FL-2309
Page 4 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 130 and 131 “D” Series Hot Cabinets
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Public link updated
The public link to your chat has been updated.
Advertisement