N8000 Series Drop-In Installation and Operation Manual
Important Warning And Safety Information
WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing
Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage,
Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The
Vicinity Of This Or Any Other Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do
Not Operate This Equipment.
WARNING Do Not Clean With Water Jet.
CAUTION Observe the following:
• Minimum clearances must be maintained from all walls and combustible
materials.
• Keep the equipment area free and clear of combustible material.
• Adequate clearance for air openings.
• Operate equipment only on the type of electricity indicated on the
specification plate.
• Retain this manual for future reference.
Delfield
™
2
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Contents
Serial Number Location
Receiving And Inspecting Unit..................................................... 3
The serial number on self-contained refrigerated units is on the electrical
specifications tag located near the condensing unit.
Specifications.......................................................................... 4-7
Installation
Curved Drop-In Cutout Details................................................... 8
N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200,
N8200G, 8100-FA, 8100-EF Series............................................. 9
N8600 Series. . .......................................................................... 9
N8700-D, N8700N, N8700-R & N8800 Series . . .......................... 10
Operation
N8100B, N8100NB, N8100-BR................................................. 11
N8100-FA............................................................................... 11
8100-EF................................................................................. 12
N8200 & N8200G. . .................................................................. 12
N8600.................................................................................... 13
The serial number on remote refrigerated units is on the outside bottom
of the food well.
On hot food pans and hot/cold combination pans, the serial number tag
is located on the back of the control raceway or remote panel.
The serial number tag also lists the refrigerant used and the amount
of charge.
Always have the serial number of your unit available when calling for
parts or service.
This manual covers only standard 8000 series units. If you have a
custom designed unit, you should contact our parts/service department
at (800) 733-8829 for questions.
N8700-D, N8700N, N8700-R & N8800 Series . . .......................... 14
Maintenance............................................................................. 15
Unit Assembly N8100-FA........................................................... 16
Wiring Diagram
©2012 The Delfield Company. All rights reserved. Reproduction without written
permission is prohibited. “Delfield” is a registered trademark of The Delfield
Company.
N8100-FA............................................................................... 16
N8100B, N8100NB & N8100-BR. . ............................................. 17
8100-EF & 8100-EFN. . ............................................................. 17
N8200 & N8200G. . .................................................................. 17
N8600............................................................................... 18-19
N8800.................................................................................... 19
N8700-D, N8700N & N8700-R................................................. 20
Louver Diagram........................................................................ 21
Miscellaneous Replacement Parts.............................................. 21
N8100-FA Replacement Parts List.............................................. 22
Condensing Unit Assembly Parts List.................................... 23-26
Food Well Assembly Parts List. . ............................................ 27-28
Standard Labor Guidelines.. ....................................................... 29
Standard Warranties............................................................ 30-31
Receiving And Inspecting The Equipment
Even though most equipment is shipped crated, care should
be taken during unloading so the equipment is not damaged
while being moved into the building.
1. Visually inspect the exterior of the package and skid or
container. Any damage should be noted and reported to
the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon
opening, there is concealed damage to the equipment
notify the carrier. Notification should be made verbally as
well as in written form.
4. Request an inspection by the shipping company of the
damaged equipment. This should be done within 10 days
from receipt of the equipment.
Delfield
™
5. Also open the compressor compartment housing and
visually inspect the refrigeration package. Be sure lines
are secure and base is still intact.
6. Freight carriers can supply the necessary damage forms
upon request.
7. Retain all crating material until an inspection has been
made or waived.
Uncrating The Equipment
First cut and remove the banding from around the crate.
Remove the front of the crate material, use of some tools will
be required.
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
3
N8000 Series Drop-In Installation and Operation Manual
Specifications
N8100B Series Self-Contained Mechanically Cooled Pans - R134A
Model
L
D
H
Counter Cutout
Dimensions
V/Hz/Ph
Amps
H.P.
BTU
Evap BTU/
TD/TEMP
Sys
Cap
Ship
Weight
Refrig.
Charge
NEMA
Plug
12”x20”
Pans
N8118B
18”
(45.7cm)
26”
(66cm)
21.87”
(55.5cm)
17” X 25”
(43.2cm x 63.5cm)
115/60/1
4.0
1/5
204
19/38º/-3º
708
100lbs
(45kg)
8.0oz
5-15P
1
N8130B
30.75”
(78.1cm)
26”
(66cm)
21.87”
(55.5cm)
29.75” x 25”
(75.6cm x 63.5cm)
115/60/1
4.0
1/5
379
26/31º/4°
812
140lbs
(64kg)
8.0oz
5-15P
2
N8143B
43.5”
(110.5cm)
26”
(66cm)
21.87”
(55.5cm)
42.50” X 25”
(108.6cm x 63.5cm)
115/60/1
4.0
1/5
569
35/26º/9º
889
173lbs
(78kg)
8.0oz
5-15P
3
N8156B
56.25”
(142.9cm)
26”
(66cm)
21.87”
(55.5cm)
55.25” x 25”
(140.3cm x 63.5cm)
115/60/1
7.0
1/4
758
43/32º/3º
1373
205lbs
(93kg)
16.0oz
5-15P
4
N8169B
69”
(175.3cm)
26”
(66cm)
21.87”
(55.5cm)
68” X 25”
(172.7cm x 63.5cm)
115/60/1
7.0
1/4
948
51/29º/6º
1469
225lbs
(102kg)
16.0oz
5-15P
5
N8181B
81.75”
(208cm)
26”
(66cm)
21.87”
(55.5cm)
80.75” x 25”
(205.1cm x 63.5cm)
115/60/1
8.0
1/3
1138
59/32º/3º
1921
258lbs
(117kg)
11.5oz
5-15P
6
N8100NB Series Self-Contained Mechanically Cooled Pans Narrow Style - R134A
N8146NB
46.75”
(118.7cm)
18”
(45.7cm)
21.81”
(55.4cm)
45.75” x 17”
(113.7cm x 43.2cm)
115/60/1
4.0
1/5
454
17/40º/-5º
680
175lbs
(80kg)
8.0oz
5-15P
2
N8168NB
67.5”
(171.5cm)
18”
(45.7cm)
21.81”
(55.4cm)
66.5” x 17”
(168.9cm x 43.2cm)
115/60/1
4.0
1/5
676
26/31º/4º
804
240lbs
(109kg)
8.0oz
5-15P
3
N8100BR Series Curved Self-Contained Mechanically Cooled Pans - R134A
L
40.43”
(103cm)
D
H
Counter Cutout
Dimensions
26.05”
(66cm)
21.81”
(55cm)
N8159-BR
57.22”
(145cm)
26.05”
(66cm)
N8176-BR
73.68”
(187cm)
N8194-BR
89.86”
(228cm)
Model
N8144-BR
V/Hz/Ph
Amps
H.P.
BTU
Evap BTU/
TD/TEMP
Sys
Cap
Ship
Weight
Refrig.
Charge
NEMA
Plug
12”x20”
Pans
see drawing on
page 8
115/60/1
4.0
1/5
379
26/31º/4°
812
161lbs
(72kg)
8.0oz
5-15P
2
21.81”
(55cm)
see drawing on
page 8
115/60/1
4.0
1/5
569
35/26º/9º
889
184lbs
(83kg)
8.0oz
5-15P
3
26.05”
(66cm)
21.81”
(55cm)
see drawing on
page 8
115/60/1
7.0
1/4
758
43/32º/3º
1373
233lbs
(105kg)
16.0oz
5-15P
4
26.05”
(66cm)
21.81”
(55cm)
see drawing on
page 8
115/60/1
7.0
1/4
948
51/29º/6º
1469
243lbs
(109kg)
16.0oz
5-15P
5
N8100-FA Series Forced Air Drop-In Mechanically Cooled Cold Pans - R404A
Model
L
D
H
Counter Cutout
Dimensions
N8131-FA
31.25”
(79.4cm)
26.67”
(67.7cm)
26.62”
(68cm)
N8144-FA
44”
(111.8cm)
26.67”
(67.7cm)
N8157-FA
56.75”
(144.1cm)
N8169-FA
N8182-FA
V/Hz/Ph
Amps
H.P.
BTU
Evap BTU/
TD/TEMP
Sys
Cap
Ship
Weight
Refrig.
Charge
NEMA
Plug
12”x20”
Pans
30.25” x 25.5”
(76.8cm x 64.8cm)
115/60/1
7.8
1/4
1339
140/15º/20º
2154
168lbs
(76kg)
16.0oz
5-15P
2
26.62”
(68cm)
43” x 25.5”
109.2cm x 64.8cm)
115/60/1
9.2
1/2
2035
140/22º/13º
3142
175lbs
(79kg)
32.0oz
5-15P
3
26.67”
(67.7cm)
26.62”
(68cm)
55.75” x 25.5”
(141.6cm x 64.8cm)
115/60/1
9.2
1/2
2731
280/14º/21°
3806
225lbs
(102kg)
32.0oz
5-15P
4
69.5”
(176.5cm)
26.67”
(67.7cm)
28.62”
(72.7cm)
68.5” x 25.5”
174.0cm x 64.8cm)
115/60/1
14.8
3/4
3374
280/20º/15°
5545
235lbs
(107kg)
48.0oz
5-20P
5
82.25”
(208.9cm)
26.67”
(67.7cm)
28.62”
(72.7cm)
81.25” x 25.5”
206.4cm x 64.8cm)
115/60/1
14.8
3/4
4070
280/20º/15°
5545
406lbs
(184kg)
48.0oz
5-20P
6
Delfield
™
4
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Specifications
8100-EF Series LiquiTec® Eutetic Fluid Refrigerated Cold Pans - R404A
Model
L
D
H
Counter Cutout
Dimensions
V/Hz/Ph
Amps
H.P.
BTU
Load
Evap BTU/
TD/TEMP
Sys
Cap
Ship
Weight
Refrig.
Charge
NEMA
Plug
12x20
Pans
8118-EF
18.20”
(46.2cm)
26”
(66cm)
23.25”
(59.1cm)
17” x 25”
(43.2cm x 63.5cm)
115/60/1
7.5
1/4
204
19/50º/-15°
928
169lbs
(77kg)
24.0oz
5-15P
1
8132-EF
31.76”
(80.7cm)
26”
(66cm)
23.25”
(59.1cm)
30.75” x 25”
(78.1cm x 63.5cm)
115/60/1
7.5
1/4
379
26/42º/-7°
1112
215lbs
(98kg)
24.0oz
5-15P
2
8145-EF
45.32”
(115.1cm)
26”
(66cm)
23.25”
(59.1cm)
44.25” x 25”
(112.4cm x 63.5cm)
115/60/1
7.5
1/4
569
35/36º/-1°
1259
265lbs
(120kg)
24.0oz
5-15P
3
8159-EF
58.88”
(149.6cm)
26”
(66cm)
23.25”
(59.1cm)
57.87” x 25”
(147cm x 63.5cm)
115/60/1
7.5
1/4
758
43/32º/3°
1373
285lbs
(130kg)
24.0oz
5-15P
4
8172-EF
72.44”
(184cm)
26”
(66cm)
23.25”
(59.1cm)
71.5” x 25”
(181.6cm x 63.5cm)
115/60/1
7.5
1/4
948
51/29º/6°
1469
295lbs
(134kg)
24.0oz
5-15P
5
8186-EF
86”
(218.4cm)
26”
(66cm)
23.25”
(59.1cm)
85” x 25”
(215.9cm x 63.5cm)
115/60/1
7.5
1/4
1138
59/26º/9°
1529
394lbs
(179kg)
24.0oz
5-15P
6
8100-EFN Series LiquiTec® Slim Line Eutetic Fluid Refrigerated Cold Pans - R404A
Model
L
D
H
Counter Cutout
Dimensions
V/Hz/Ph
Amps
H.P.
BTU
Load
Evap BTU/
TD/TEMP
Sys
Cap
Ship
Weight
Refrig.
Charge
NEMA
Plug
12x20
Pans
8148-EFN
47.66”
(121.1cm)
18”
(45.7cm)
23.25”
(59.1cm)
46.88” x 17.25”
(119.1cm x 43.8cm)
115/60/1
7.5
1/4
379
26/42º/-7°
1112
235lbs
(107kg)
24.0oz
5-15P
2
8169-EFN
69.22”
(175.8cm)
18”
(45.7cm)
23.25”
(59.1cm)
68.5” x 17.25”
(174cm x 43.8cm)
115/60/1
7.5
1/4
569
35/36º/-1°
1259
285lbs
(130kg)
24.0oz
5-15P
3
8191-EFN
90.78”
(230.6cm)
18”
(45.7cm)
23.25”
(59.1cm)
90” x 17.25”
(228.6cm x 43.8cm)
115/60/1
7.5
1/4
758
43/32º/13°
1373
295lbs
(134kg)
24.0oz
5-15P
4
N8000 Series Ice Cooled Cold Pans
Counter Cutout
Dimensions
Ship
Weight
12”x20”
Pans Held
17” x 25”
(43.2cm x 63.5cm)
38lbs
(17kg)
1
10.75”
(27.3cm)
29.75” x 25”
(75.6cm x 63.5cm)
84lbs
(38kg)
2
26”
(66cm)
10.75”
(27.3cm)
42.5” x 25”
(107.9cm x 63.5cm)
110lbs
(50kg)
3
56.25”
(142.9cm)
26”
(66cm)
10.75”
(27.3cm)
55.25” x 25”
(140.3cm x 63.5cm)
139lbs
(63kg)
4
N8069
69”
(175.3cm)
26”
(66cm)
10.75”
(27.3cm)
68” x 25”
(172.7cm x 63.5cm)
160lbs
(73kg)
5
N8081
81.75”
(208cm)
26”
(66cm)
10.75”
(27.3cm)
80.75” x 25”
(205.1cm x 63.5cm)
197lbs
(89kg)
6
100lbs
(45kg)
120lbs
(55kg)
2
Model
L
18”
(45.7cm)
D
26”
(66cm)
H
10.75”
(27.3cm)
N8030
30.75”
(78.1cm)
26”
(66cm)
N8043
43.5”
(110.5cm)
N8056
N8018
N8000N Series Narrow Ice Cooled Cold Pans
46.75”
(118.8cm)
67.5”
(171.5cm)
N8046N
N8068N
18”
(45.7cm)
10.75”
(27.3cm)
18”
(45.7cm)
10.75”
(27.3cm)
Delfield
™
45.75” x 17”
(116.2cm x 43.2cm)
66.50” x 17”
(168.9cm x 43.2cm)
3
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
5
N8000 Series Drop-In Installation and Operation Manual
Specifications
N8000-R Series Curved Ice Cooled Cold Pans
Model
Counter Cutout
Dimensions
Ship
Weight
12”x20”
Pans Held
see drawing on page 8
100lbs
(45kg)
2
10.77”
(27cm)
see drawing on page 8
118lbs
(53kg)
3
26.05”
(66cm)
10.77”
(27cm)
see drawing on page 8
145lbs
(65kg)
4
26.05”
(66cm)
10.77”
(27cm)
see drawing on page 8
164lbs
(74kg)
5
L
40.48”
(103cm)
D
26.05”
(66cm)
H
10.77”
(27cm)
N8059-R
57.22”
(145cm)
26.05”
(66cm)
N8076-R
73.68”
(187cm)
N8094-R
89.89”
(228cm)
N8044-R
N8200 Series Self-Contained Frost Tops - R404A
Model
L
D
H
Counter Cutout
Dimensions
V/Hz/Ph
Amps
H.P.
BTU
Evap BTU/
TD/TEMP
Sys
Cap
N8231
31.75"
(80.6cm)
26”
(66cm)
15.75”
(40cm)
N8245
45.63”
(115.9cm)
26”
(66cm)
N8259
59.5”
(151.1cm)
N8273
N8287
Refrig.
Charge
NEMA
Plug
30.75” x 25"
(78.1cm x 63.5cm)
115/60/1
7.5
1/4
379
26/42º/-7°
1112
142lbs
(64kg)
24.0oz
5-15P
15.75”
(40cm)
44.63” x 25”
(113.3cm x 63.5cm)
115/60/1
7.5
1/4
569
35/36º/-1°
1259
168lbs
(76kg)
24.0oz
5-15P
26”
(66cm)
15.75”
(40cm)
58.50” x 25”
(148.6cm x 63.5cm)
115/60/1
7.5
1/4
758
43/32º/3°
1373
193lbs
(88kg)
24.0oz
5-15P
73.38"
(186.4cm)
26”
(66cm)
15.75”
(40cm)
72.38” x 25”
(183.8cm x 63.5cm)
115/60/1
8.0
1/4
948
51/29º/6°
1469
209lbs
(95kg)
24.0oz
5-15P
87.25"
(221.6cm)
26”
(66cm)
15.75”
(40cm)
86.25" x 25"
(219.1cm x 63.5cm)
115/60/1
8.0
1/3
1138
59/30º/5°
1787
239lbs
(108kg)
24.0oz
5-15P
Refrig.
Charge
NEMA
Plug
Ship Weight
N8200G Series Self-Contained Granite Cold Slabs
Model
L
D
H
Counter Cutout
Dimensions
V/Hz/Ph
Amps
H.P.
BTU
Evap BTU/
TD/TEMP
Sys
Cap
N8231G
31.75”
(80.6cm)
25.87”
(65.7cm)
19”
(48.3cm)
30.75” X 25”
(78.1cm x 63.5cm)
115/60/1
7.5
1/4
379
26/42º/-7°
1112
219lbs
(99kg)
24.0oz
5-15P
N8245G
45.63”
(115.9cm)
25.87”
(65.7cm)
19”
(48.3cm)
44.63” x 25”
(113.4cm x 63.5cm)
115/60/1
7.5
1/4
569
35/36º/-1°
1259
284lbs
(129kg)
24.0oz
5-15P
N8259G
59.5”
(151.1cm)
25.87”
(65.7cm)
19”
(48.3cm)
58.5” x 25”
(148.6cm x 63.5cm)
115/60/1
8.0
1/3
758
43/37º/-2°
1572
338lbs
(153kg)
24.0oz
5-15P
N8273G
73.38”
(186.4cm)
25.87”
(65.7cm)
19”
(48.3cm)
72.38” x 25”
(183.8cm x 63.5cm)
115/60/1
9.0
1/2
948
51/43º/-8°
2183
425lbs
(193kg)
32.0oz
5-15P
Ship Weight
N8600 Series Self Contained Combination Hot/Cold Food Wells - R404A
Model
L
D
H
Counter Cutout
Dimensions
Control Panel Cutout
Dimensions
V/Hz/Ph
Amps
H.P.
BTU
Evap BTU/
TD
Sys
Cap
Ship
Weight
Refrig.
Charge
N8630
30.75”
(78.1cm)
26”
(66cm)
23.75”
(60.3cm)
29.75” X 25”
(75.5cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
120/60/1
24.0
1/4
379
26/42º/-7°
1112
164lbs
(74kg)
16.0oz
2
N8643
43.5”
(110.5cm)
26”
(66cm)
23.75”
(60.3cm)
42.50” x 25”
(107.9cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
120/240
/60/1
21.0
1/4
569
35/36º/-1°
1259
198lbs
(90kg)
16.0oz
3
N8656
56.25”
(142.9cm)
26”
(66cm)
23.75”
(60.3cm)
55.25” x 25”
(140.3cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
120/240
/60/1
21.0
1/4
758
43/32º/3°
1373
233lbs
(106kg)
16.0oz
4
N8669
69”
(175.3cm)
26”
(66cm)
23.75”
(60.3cm)
68” x 25”
(172.7cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
120/240
/60/1
42.0
1/4
948
51/29º/6°
1469
266lbs
(121kg)
16.0oz
5
N8681
81.75”
(207.6cm)
26”
(66cm)
23.75”
(60.3cm)
80.75” x 25”
(205.1cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
120/240
/60/1
42.0
1/3
1138
59/30º/5°
1787
301lbs
(137kg)
24.0oz
6
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
Pans
Delfield
™
6
12”x20”
®
N8000 Series Drop-In Installation and Operation Manual
Specifications
N8700D Series Individually Controlled Heated Food Wells
Ship
Weight
12”x20”
Pans
8.3
41lbs
(19kg)
1
120/60/1
16.6
99lbs
(45kg)
2
14.5” x 4.62” x 7.00”
(36.8cm x 11.7cm x 17.8cm)
208-230
/60/1
15.0/16.0
134lbs
(61kg)
3
58.5” x 25”
(148.6cm x 63.5cm)
18.69” x 4.62” x 7.00”
(47.5cm x 11.7cm x 17.8cm)
208-230
/60/1
20.0/22.0
166lbs
(75kg)
4
9.5”
(24cm)*
72.37” x 25”
(183.8cm x 63.5cm)
22.88” x 4.62” x 7.00”
(58.1cm x 11.7cm x 17.8cm)
208-230
/60/1
24.0/27.0
186lbs
(84kg)
5
9.5”
(24cm)*
86.25” x 25”
(219.1cm x 63.5cm)
27” x 4.62” x 7.00”
(68.6cm x 11.7cm x 17.8cm)
208-230
/60/1
29.0/32.0
236lbs
(107kg)
6
Ship
Weight
12”x20”
Pans
Counter Cutout
Dimensions
L
17.88”
(45.4cm)
D
26”
(66cm)
H
9.5”
(24cm)*
16.88” X 25”
(42.8cm x 63.5cm)
Control Panel Cutout
Dimensions
7.00” x 4.62” x 7.00”
(17.8cm x 11.7cm x 17.8cm)
N8731-D
31.75”
(80.6cm)
26”
(66cm)
9.5”
(24cm)*
30.75” x 25”
(78.1cm x 63.5cm)
N8745-D
45.63”
(115.9cm)
26”
(66cm)
9.5”
(24cm)*
N8759-D
59.5”
(151.1cm)
26”
(66cm)
N8773-D
73.38”
(186.4cm)
N8787-D
87.25”
(221.4cm)
Model
N8717-D
V/Hz/Ph
Amps
120/60/1
10.31” x 4.62” x 7.00”
(26.2cm x 11.7cm x 17.8cm)
44.62” x 25”
(113.3cm x 63.5cm)
9.5”
(24cm)*
26”
(66cm)
26”
(66cm)
*14” Overall height including drain connection
N8700-R Series Curved Individually Controlled Heated Food Wells
Model
Counter Cutout
Dimensions
Amps
120/60/1
16.6
99lbs
(45kg)
2
14.5” x 4.62” x 7.00”
(37cm x 12cm x 18cm)
208-230
/60/1
15.0/16.0
134lbs
(61kg)
3
see drawing on page 8
18.69” x 4.62” x 7.00”
(47cm x 12cm x 18cm)
208-230
/60/1
20.0/22.0
166lbs
(75kg)
4
see drawing on page 8
22.88” x 4.62” x 7.00”
(58cm x 12cm x 18cm)
208-230
/60/1
24.0/27.0
186lbs
(84kg)
5
D
26.05”
(66cm)
H
9.5”
(24cm)*
N8759-R
57.22”
(145cm)
26.05”
(66cm)
9.5”
(24cm)*
see drawing on page 8
N8776-R
73.68”
(187cm)
26.00”
(66cm)
9.5”
(24cm)*
N8794-R
89.80”
(228cm)
25.91”
(66cm)
9.5”
(24cm)*
N8744-R
Control Panel Cutout
Dimensions
10.31” x 4.62” x 7.00”
(26cm x 12cm x 18cm)
V/Hz/Ph
L
40.48”
(103cm)
see drawing on page 8
*14” Overall height including drain connection
N8700N Series Individually Controlled Heated Narrow Food Wells
Model
L
D
H
N8746N
N8746ND
45.61”
(116cm)
67.48”
(172cm)
15.87”
(40cm)
9.5”
(24cm)
15.87”
(40cm)
9.5”
(24cm)
N8768N
N8768ND
Counter Cutout
Dimensions
Control Panel Cutout Dimensions
44.62” x 15.0”
(113.3cm x 38.1cm)
66.50” x 15.0”
(168.9cm x 38.1cm)
10.31” x 4.62” x 7.00”
(26.2cm x 11.7cm x 17.8cm)
14.50” x 4.62” x 7.00”
(36.8cm x 11.7cm x 17.8cm)
V/Hz/Ph
Amps
120/60/1
17.0
208-230
/60/1
15.0/16.0
Ship
Weight
12”x20”
Pans
100lbs
(45kg)
130lbs
(59kg)
2
Ship
Weight
12”x20”
Pans
3
*ND Models are standard with drains
N8800 Series Single Tank Electric Hot Food Wells
Model
L
D
H
Counter Cutout
Dimensions
Control Panel Cutout Dimensions
N8831
31.75”
(80.6cm)
26”
(66cm)
11”
(27.9cm)
30.75” X 25”
(78.1cm x 63.5cm)
N8845
45.63”
(115.9cm)
26”
(66cm)
11”
(27.9cm)
N8859
59.5”
(151.1cm)
26”
(66cm)
N8873
73.38”
(186.4cm)
N8887
87.25”
(221.6cm)
V/Hz/Ph
Amps
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
120/60/1
17.0
100lbs
(45kg)
2
44.63” x 25”
(113.4cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
208-230
/60/1
15.0/16.0
136lbs
(62kg)
3
11”
(27.9cm)
58.5” x 25”
(148.6cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
208-230
/60/1
20.0/22.0
158lbs
(72kg)
4
26”
(66cm)
11”
(27.9cm)
72.38” x 25”
(183.8cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
208-230
/60/1
24.0/27.0
195lbs
(88kg)
5
26”
(66cm)
11”
(27.9cm)
86.25” x 25”
(219.1cm x 63.5cm)
12.25” x 4.25” x 7.00”
(31.1cm x 10.8cm x 17.8cm)
208-230
/60/1
29.0/32.0
224lbs
(102kg)
6
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
7
N8000 Series Drop-In Installation and Operation Manual
Curved Drop-In Cutout Details
2 pan standard curved drop-in cutout detail
Models:
19.75”
• N8044-R
50cm
• N8144-BR
• N8744-R
19.75”
50cm
172.50˚
85˚
2-PAN STD.
RADIAL DROP-IN
CUTOUT DETAIL
25.00”
64cm
25.00”
64cm
25.10”
64cm
85˚
25.10”
64cm
95˚
95˚
172.50˚
15.92”
40cm
15.92”
40cm
3 pan standard curved drop-in cutout detail
Models:
19.56”
• N8059-R
50cm
• N8159-BR
• N8759-R
17.06”
43cm
3-PAN STD.
RADIAL DROP-IN
CUTOUT DETAIL
25.00”
64cm
25.00”
64cm
25.10”
64cm
172.50˚
172.50˚
85˚
19.56”
50cm
85˚
25.00”
64cm
95˚
25.10”
64cm
95˚
13.78”
35cm
15.73”
40cm
4 pan standard curved drop-in cutout detail
Models:
• N8076-R
19.56”
50cm
• N8176-BR
• N8776-R
15.73”
40cm
17.06”
43cm
17.06”
43cm
172.50˚
172.50˚
19.56”
50cm
172.50˚
85˚
85˚
4-PAN STD.
RADIAL DROP-IN
CUTOUT DETAIL
25.00”
64cm
25.00”
64cm
25.00”
64cm
25.00”
64cm
25.10”
64cm
25.10”
64cm
95˚
95˚
15.73”
40cm
5 pan standard curved drop-in cutout detail
Models:
• N8094-R
19.50”
• N8194-BR
50cm
• N8794-R
13.78”
35cm
13.78”
35cm
15.73”
40cm
17.06”
43cm
17.06”
43cm
17.06”
43cm
19.50”
50cm
172.50˚
172.50˚
172.50˚
172.50˚
85˚
85˚
25.00”
64cm
5-PAN STD.
RADIAL DROP-IN
CUTOUT DETAIL
25.00”
64cm
25.00”
64cm
25.00”
64cm
25.00”
64cm
25.10”
64cm
25.10”
64cm
95˚
95˚
15.67”
40cm
13.78”
35cm
13.78”
35cm
13.78”
35cm
15.67”
40cm
Delfield
™
8
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Installation N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200, N8200G, N8100-FA & 8100-EF
These units are intended for indoor use only. A room
temperature of no more than 86°F (30°C) is recommended.
Be sure the location chosen has a counter strong enough to
support the total weight of the unit and contents. A fully loaded
model may weigh as much as 600 pounds! Reinforce the
counter as necessary to provide maximum loading.
DANGER
CAUTION
Some N8000, N8000N, N8000-R, N8100B,
N8100NB
and
N8100-BR
may
have
polyethylene insulation in the drain hole.
This can easily be cut out without any contact
or damage to the units interior insulation or
refrigeration lines.
Unit requires that the sides and bottom are not
any closer than 3” (7.6cm) to any combustible
material.
The counter cut-out sizes and power requirements are shown
on the specification pages. A gasket is installed in the flange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
Louvers
Self-contained refrigerated units (N8100, N8100NB, N8100-BR,
N8200 and N8200G Series) require airflow to the compressor.
A 13” x 25” (33 cm x 63.5 cm) louver is provided by Delfield and
must be installed in the counter in front of the condenser. The
louver cutout dimension is 11” x 22” (27.9 cm x 55.9 cm). The
rear must have an opening to permit removal of heated air. The
opening must be at least 8” x 11”, a total of 88 square inches
(20.3 cm x 27.9 cm, a total of 566 square centimeters).
Plumbing
The units drain must have an outlet to an appropriate drainage
area or container. A drain trap must be installed. N8200 series
have 1/2” drain and N8200G series have 3/4” drain located on
end/center. The 1” diameter drain on N8000, N8000-R, N8100,
N8100NB, N8100-BR, N8100-FA and 8100-EF Series units
is shipped loose and must be connected during installation.
N8157-FA, N8169-FA, and N8182-FA have two drains.
Moisture collecting from improper drainage
can create a slippery surface on the floor
and a hazard to employees. It is the owner’s
responsibility to provide a container or outlet
for drainage.
Electrical connection
Refer to the amperage data on the specification pages, the
serial tag or your local code to be sure the unit is connected
to the proper power source. A protected circuit of the correct
voltage and amperage must be run for con­nec­tion of the line
cord.
Some units have an ON/OFF switch located behind the
louvered panel in the machine compartment. Simply turn the
switch to ON to begin operation.
Some units have an OFF position on the thermostat dial which is
located behind the louvered panel in the machine compartment.
Simply turn the dial to begin operation.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
Never operate the unit without the louvered
panel in place!
Installation N8600
These units are intended for indoor use only. A room temperature
of no more than 86°F (30°C) is recommended. Be sure the
location chosen has a counter strong enough to support the
total weight of the unit and contents. A fully loaded model
may weigh as much as 600 pounds! Reinforce the counter as
necessary to provide for maximum loading.
DANGER
Unit requires that the sides and bottom are not
any closer than 3” (7.6cm) to any combustible
material.
The counter cut-out sizes and power requirements are shown
on the specification pages. A gasket is installed in the flange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
The cut-out dimensions for the control box on N8600 Series
units is 4.25” x 12.25” (10.8 cm x 31.1 cm).
Louvers
For proper refrigerated operation, N8600 Series units require
airflow to the compressor. A 13” x 25” louver is (33.0 cm x 63.5
cm) is provided by Delfield and must be installed in the counter
in front of the condenser. The louver cutout dimension is 11”
Delfield
™
®
x 22” (27.9 cm x 55.9 cm). The rear must have an opening to
permit removal of heated air. The opening must be at least 8” x
11”, a total of 88 square inches (20.3 cm x 27.9 cm, a total of 566
square centimeters).
Plumbing
The units 1” (2.54cm) drain must have an outlet to an appropriate
drainage area or container.
CAUTION
Moisture collecting from improper drainage
can create a slippery surface on the floor
and a hazard to employees. It is the owner’s
responsibility to provide a container or outlet
for drainage.
Electrical connection
Refer to the amperage data on the specification pages, the
serial tag or your local code to be sure the unit is connected to
the proper power source.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
Never operate the unit without the louvered
panel in place!
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
9
N8000 Series Drop-In Installation and Operation Manual
Installation N8700-D, N8700N, N8700-R & N8800 Series
These units are intended for indoor use only. Be sure the
location chosen has a counter strong enough to support the
total weight of the unit and contents. A fully loaded model
may weigh as much as 600 pounds! Reinforce the counter as
necessary to provide maximum loading.
DANGER
Unit requires that the sides and bottom are not
any closer than 3” (7.6cm) to any combustible
material.
The counter cut-out sizes and power requirements are shown
on the specification pages. A gasket is installed in the flange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
N8700 Series pans should be installed with the
drains at the back, away from the operator’s
sides.
Plumbing
N8700-D, N8700N-D and N8700-R Plumbing: Unit is equipped
with 1/2” (1.3cm) drains, (one per well located in right rear corner
1/2” (1.3cm) female N.P.T.) manifold and 1/2” (1.3cm) gate valve.
N8800 Plumbing: Well is sloped to a 1.00” (2.5cm) male N.P.T.
stainless steel drain.
CAUTION
Moisture collecting from improper drainage
can create a slippery surface on the floor
and a hazard to employees. It is the owner’s
responsibility to provide a container or outlet
for drainage.
Electrical connection
Refer to the amperage data on the specification pages, the
serial tag or your local code to be sure the unit is connected to
the proper power source.
The controls on N8700-D, N8700-R and N8800 series units
are mounted in a control panel, designed to be installed at a
“remote” location. The control panel should be installed so that
the indicator light for each control is to the right of the control.
N8700, N8700N and N8700-R series units have 48” (121.9cm)
of conduit and N8800 Series units have 24” (61.0cm) of conduit
between the pans and the remote control panel to facilitate this
installation.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
Control Panel Installation, N8700-D, N8700N & N8700-R Series
The control panel is designed to be installed on the side
opposite the drains.
If you choose to install the control panel on the same side as the
drains the control panel will either be upside down or the knobs
will control the opposite wells.
Control panel
installed
opposite drains
Drains
Delfield
™
10
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Operation N8100B, N8100NB & N8100-BR
N8100 Series mechanically cooled cold pans are adjusted
at the factory to provide proper operation without any further
adjustments. However, if it is necessary to adjust the
temperature, the control is located in the machine compartment.
Turn the knob clockwise as indicated on the control. Settings
are from 1 thru 7 (7 being the coldest). Adjustments should
be made gradually. Several small adjustments will be more
effective than one large adjustment. It may take an hour or
longer to realize the temperature change depending on the
application and location of the unit.
These units are not designed to cool warm food products. Items
should be placed in the unit pre-cooled at least to the desired
holding temperature, if not slightly colder. In some applications,
a gradual warming of product may occur, particularly at the
exposed top of the product. Stirring or rotation of the product
may be necessary to maintain overall temperature.
Warming of food product can occur very quickly outside of the
unit. When loading or rotating product, avoid leaving food items
in a non-refrigerated location for any length of time to prevent
warming or spoilage.
The temperature control is used to turn the unit on and off as
well as control the temperature of the cold pan. The settings
range from 1 through 7 (7 being the coldest). To turn the cold
pan off, turn the knob to the off position.
If the cold pan is to be used with ice, it is recommended that
the optional perforated bottoms be used. These will allow ice
to melt properly.
The unit must be turned off when not in use or overnight for
defrosting and cleaning.
18000 and CTP-NB Series Service and Installation Manual
REFRIGERANT CHARGES AND PRESSURE CONTROL SETTINGS
Refrigerant Charges For 18000 Series Units:
18648-PTB . . . . . . . . . . . . . . . . . . . . . . .16 oz.
18660-PTB . . . . . . . . . . . . . . . . . . . . . . .24 oz.
18672-PTB . . . . . . . . . . . . . . . . . . . . . . .32 oz.
18691-PTB . . . . . . . . . . . . . . . . . . . . . . .32 oz.
N8100-FA Series forced air mechanically
cooled cold pans come
18699-PTB . . . . . . . . . . . . . . . . . . . . . . .48 oz.
186114-PTB
. . . . . . . . .refrigeration
. . . . . . . . . . . . .48 oz.
equipped with 115-volt, 60 Hertz, single
phase
Operation N8100-FA
18648-BUC . . . . . . . . . . . . . . . . . . . . . . .16 oz.
18660-BUC . . . . . . . . . . . . . . . . . . . . . . .16 oz.
Ruby 18672-BUC
Tuesday Salad
. . Bar
. . . Service
. . . . . .and
. . .Installation
. . . . . . . . Manual
.16 oz.
18691-BUC
. . . . . . . . . . . . . . . . . . . . . . .16 oz.
DEFROST
TIMER
Defrost
Timer
18699-BUC . . . . . . . . . . . . . . . . . . . . . . .24 oz.
186114-BUC
. . . . . for
. . . . .15
. . . .minutes.
. . . . . . . .24 oz.
Every
2 hours
units. The refrigeration valves are open and ready to operate
Series Units:
as soon as the power supply cord isRefrigerant
pluggedCharges
into For
theCTP-NB
standard
115-volt, grounded electrical outlet. CTP8146-NB . . . . . . . . . . . . . . . . . . . . . . .8 oz.
CTP8160-NB . . . . . . . . . . . . . . . . . . . . . . .8 oz.
CTP8175-NB . . . . . . . . . . . . . . . . . . . . . . .8 oz.
Pressure Control
The temperature is controlled by an adjustable pressure control
PRESSUREand
CONTROL
SETTINGS
located in the machine compartment
adjustable
control has
the word COLDER near the
knob,
withSettings
an arrow to indicate the
Pressure
Control
adjustment direction. ThisThecontrol
is field adjustable and does
factory recommended low-pressure control settings for 18000-PTB’s are: 55# cut-in and 30# cut-out to maintain
not require a service agent.
If temperature
you have
any questions,
feeltemperature
free is controlled by the thermostat mounted on the
proper
for product
in the rail. The interior
evaporator coil housing.
to contact the Delfield Service
Department
at
(800)
733-8829.
The factory recommended low-pressure control settings for 18000-BUC’s are: 82# cut-in and 57# cut-out to maintain
proper temperature.
In attempting to adjust the pressure control,
All Delfield refrigerated
models
comeby
equipped
with
you can do damage
to the
unit
accidentally
115-volt, 60 cycle, single phase refrigeration units. The
adjusting the
differential.
Delfield
refrigeration
valves are open and ready
to operate asis
soon not
as the
power supply incurred
cord is plugged while
into the standard
115responsible for
charges
adjusting
volt, grounded electrical outlet.
the pressure control.
Pressure Control
The temperature is controlled by an adjustable pressure
control located in
the machine
compartment.
Food in the N8100-FA
pans
should
not An
beadjustable
loaded
has the word COLDER near the knob, with an arrow
in such a waycontrol
as
to
interfere
with
the
air
curtain
to indicate the adjustment direction. These controls are
field adjustable
and do not require a service agent. If you
flowing over the
cold pans.
30 psi (207 kPa) differential
80 psi (552 kPa) cut-in
50 psi (345 kPa) cut-out
have any questions, feel free to contact the Delfield Service
Department.
In attempting to adjust the pressure control,
you can do damage to your unit by accidentally
adjusting the differential. Please make small
incremental adjustments if a temperature
adjustment is necessary, please contact the
service department at Delfield (800) 733-8821
or your local service agent. Delfield is not
responsible for charges incurred while having
the pressure control adjusted.
8
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Delfield
™
5
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
11
N8000 Series Drop-In Installation and Operation Manual
Operation 8100-EF Series
There is a switch on the compressor housing front to turn the
8100-EF units on and off. 8100-EF Series LiquiTec® Eutetic
fluid cold pans are adjusted at the factory to provide proper
operation without any further adjustments. However, if it is
necessary to adjust the temperature, the control is located in the
machine compartment. Turn the knob clockwise as indicated
on the control to adjust it colder. Adjustments should be made
gradually. Several small adjustments will be more effective than
one large adjustment. It may take an hour or longer to realize
the temperature change depending on the application and
location of the unit.
The unit must be turned off when not in use or overnight for
defrosting and cleaning.
Temperature Control Settings:
17°F (8ºC) differential
25°F (-4ºC) cut-in
8°F (-13ºC)cut-out
These units are not designed to cool warm food products. Items
should be placed in the unit pre-cooled at least to the desired
holding temperature, if not slightly colder. In some applications,
a gradual warming of product may occur, particularly at the
exposed top of the product. Stirring or rotation of the product
may be necessary to maintain overall temperature. Warming
of food product can occur very quickly outside of the unit.
When loading or rotating the product, avoid leaving food items
in a non-refrigerated location for any length of time to prevent
warming or spoilage.
The cold pan is not intended to be used with
ice.
Operation N8200
N8200 Series frost tops are designed to maintain an even layer
of frost to pleasantly display product. Once turned on, the
compressor will run continuously. The unit should be turned off
overnight or when not in use. There is no temperature control
on the N8200 series. The ON/OFF switch is the only means
available to cycle the unit.
Since it takes time for the frost to accumulate initially, the unit
should be turned on approximately one hour before it is actually
required. Product should not be placed on the frost top prior to
turning the unit on, because it may freeze to the surface of the
unit.
The unit must be turned off when not in use or overnight for
defrosting and cleaning.
Operation N8200G
N8200G Series granite cold slabs are designed to maintain a
low temperature surface for quick turn products such as ice
cream. Frost patterns will vary depending on room conditions
such as temperature, humidity and airflow. The “work zone”
of the granite surface is considered to be inside a 2” (5.1cm)
perimeter. Temperatures in the perimeter zone may be higher
and again the frost patterns in this area will vary based on room
conditions.
Unit is controlled by an on/off switch. Once turned on, the unit
will run continuously. There is no temperature control in this
unit. Turn the unit on approximately two hours prior to use to
allow for ample cool down time. The unit must be turned off
when not in use or overnight for defrosting and cleaning.
Delfield
™
12
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Operation N8600 Hot/Cold Series
Hot Operation
N8600 Series hot and cold combination pans must be operated
with water in the well for proper hot operation. Fill well with a
minimum of 4” (10.2cm) of water. Place function switch in HOT
position to begin heating. Turn thermostat dial to the desired
temperature.
Never use anything other than plain water
in the wells or tank. Failure to observe this
warning may result in personal injury or
damage to the unit.
DA NG ER
When operated at the highest temperature
setting, the top of the unit will become very
hot. Staff and customers using the equipment
should be informed about this.
To turn unit off, simply move the function switch to OFF position.
Drain water and allow unit to cool before cleaning or switching
to cold operation.
Cold Operation
Simply place the function switch to the COLD position. The
compressor controller has been factory set and no temperature
adjustment should be necessary. If the cold pan is to be used
with ice, it is recommended that the optional perforated bottoms
be used. These will allow ice to melt properly.
Switching from hot to cold operation
Follow this procedure:
1. Place the function switch in the OFF position
and drain out hot water.
2. Allow the unit to cool until it can be safely
cleaned.
STEP S
3. When clean up procedures are complete, unit
will be ready for cold operation. This takes
about one hour.
To assure maximum compressor life, do not
switch from “hot” to “cold” operation without
allowing a cool down period. Never switch from
hot to cold operation while hot water remains in
the pans. Failure to observe this warning will
greatly reduce compressor life and eventually
cause premature compressor failure.
Switching from cold to hot operation
No special procedure is required to switch from the cold to hot
operation. Be certain to fill will with a minimum of 4” of water.
The unit is designed so that the compressor
and the heating elements cannot operate at
the same time. Continued operation of the
compressor in the “hot position” should not
be considered normal. Call for service if this
happens.
The unit must be turned off when not in use or overnight for
defrosting and cleaning.
N8600 Immersion Heater Reset Switch
As a safety feature the N8600 food well immersion heater has a
reset switch. If the heater gets too hot, it will turn off. Low or no
water can be the cause.
The unit must be turned off when you push
the manual reset switch.
Access Hole for N8600 Immersion
Heater Reset Switch
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
13
N8000 Series Drop-In Installation and Operation Manual
Operation N8700-D, N8700N, N8700-R & N8800 Series
These units are designed to hold warm food product between
140F to 160F (60C to 71C).
N8700-D, N8700N and N8700-R series individually heated
hot food units may be operated “wet” (with water in the wells)
or “dry”. However, “wet” operation is recommended for better
performance.
Wet Operation
Fill the food well with a minimum of 2” (5.1cm) of water and
cover with lid or empty pan. To preheat water, set temperature
control at “HI”. With pans in place, wells will boil water. Food
temperature will vary depending on type and amount of product.
To minimize steam and water usage, set control at lowest
setting that will maintain proper food temperature. To reduce
preheating time, use hot water to fill the well.
N8800 Series single tank hot food units are designed to be
operated “wet” (with water in the tank) only.
When operating these units “wet,” never use
anything other than plain water in the wells or
tank. Failure to observe this warning may result
in personal injury or damage to the unit.
Proper water level (approximately 2” [5.1cm])
must be maintained to prevent damage to the
tank on the N8800 Series units.
After the unit is hard wired to the electrical system, select
desired temperature by rotating temperature control. A knob
and indicator light are provided for each individual heated food
well.
First Time Use
Before the unit is used the first time for serving, turn the
temperature knob to “HI” and heat the well for 20 to 30 minutes.
Any residue or dust that adhered to the heater element(s) will
be burned off during this initial preheat period.
When serving thick sauces always use the hot food well in
“wet” operation. This provides more uniform temperature for
the sauce.
Never place food directly in well. Always use
pans.
DA NG ER
DA NG ER
When operated at the highest temperature
setting, the top of the unit will become very
hot. Staff and customers using the equipment
should be informed about this.
Steam can cause serious burns. Always use
some type of protective covering on your hands
and arms when removing lids from the unit. Lift
the lid in a way that will direct escaping steam
away from your face and body.
Dry Operation N8700 Series only
Wet operation is usually much more efficient and is preferred.
However, these units may be operated without water with no
damage to the unit.
When operated dry, the bottom of the well will discolor. To clean,
use a stainless steel cleaner or mild abrasive.
The dry well should never be preheated longer
than 15 minutes.
For most efficient operation, keep covered inserts in each well
during preheating or when empty.
Always place covers on pans when not serving to prevent food
from drying out.
DA NG ER
When operated dry, the well bottoms become
very hot. Do not allow unprotected skin to
contact any well surface.
Delfield
™
14
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Maintenance
Drain Maintenance - N8100-FA Series
Each unit has a drain located inside the unit that removes
the condensation from the evaporator coil and routes it to an
external condensate evaporator pan. Each drain can become
loose or disconnected during normal use. If you notice water
accumulation on the inside of the unit be sure the drain tube
is connected to the evaporator drain pan. If water is collecting
underneath the unit make sure the end of the drain tube is in
the condensate evaporator in the machine compartment. The
leveling of the unit is important as the units are designed to
drain properly when level. Be sure all drain lines are free of
obstructions.
The power switch must be turned to OFF and
the unit disconnected from the power source
whenever performing service, maintenance
functions or cleaning the refrigerated area.
Stainless Steel Care and Cleaning
To prevent discoloration or rust on stainless steel several
important steps need to be taken. First, we need to understand
the properties of stainless steel. Stainless steel contains 70- 80%
iron, which will rust. It also contains 12-30% chromium, which
forms an invisible passive film over the steel’s surface, which
acts as a shield against corrosion. As long as the protective
layer is intact, the metal is still stainless. If the film is broken or
contaminated, outside elements can begin to breakdown the
steel and begin to form discoloration or rust. Proper cleaning
of stainless steel requires soft cloths or plastic scouring pads.
Cleaning the Condenser Coil
In order to maintain proper refrigeration performance, the
condenser fins must be cleaned of dust, dirt and grease
regularly. It is recommended that this be done at least every
three months. If conditions are such that the condenser is totally
blocked in three months, the frequency of cleaning should be
increased. Clean the condenser with a vacuum cleaner or stiff
brush. If extremely dirty, a commercially available condenser
cleaner may be required.
Failure to maintain a clean condenser coil can initially cause high
temperatures and excessive run times. Continuous operation
with a dirty or clogged condenser coil can result in compressor
failure. Neglecting the condenser coil cleaning procedures will
void any warranties associated with the compressor and cost to
replace the compressor.
CAUTION
Never use a high-pressure water wash for this
cleaning procedure as water can damage the
electrical components located near or at the
condenser coil.
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
Cleaning solutions need to be alkaline based or non-chloride
cleaners. Any cleaner containing chlorides will damage
the protective film of the stainless steel. Chlorides are also
commonly found in hard water, salts, and household and
industrial cleaners. If cleaners containing chlorides are used be
sure to rinse repeatedly and dry thoroughly. Routine cleaning
of stainless steel can be done with soap and water. Extreme
stains or grease should be cleaned with a non-abrasive cleaner
and plastic scrub pad. Always rub with the grain of the steel.
There are stainless steel cleaners available which can restore
and preserve the finish of the steels protective layer. Early signs
of stainless steel breakdown are small pits and cracks. If this
has begun, clean thoroughly and start to apply stainless steel
cleaners in attempt to restore the passivity of the steel.
Never use an acid based cleaning solution!
Many food products have an acidic content,
which can deteriorate the finish. Be sure to clean
the stainless steel surfaces of ALL food
products. Common items include, tomatoes,
peppers and other vegetables.
CAUTION
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
15
N8000 Series Drop-In Installation and Operation Manual
Unit Assembly N8100-FA
UPRIGHT AIR DIFFUSER
WITH AIR DEFLECTOR
BLACK AIRFLOW EXTRUSIONS
PERFORATED PAN CLIP
ADAPTER BARS
COIL ASSY COVER
PLEXIGLAS END CAPS
Wiring Diagram N8100-FA
MODELS - NORDIC BREEZE
L1
N
1
2
5
G
3
PRESSURE
CONTROL
CONDENSING UNIT
DEFROST TIMER
COOLING FANS
M:\RFBACKUP\DRAWINGS\NORDICWD.DWG
Delfield
™
16
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Wiring Diagram N8100B, N8100NB & N8100-BR
CONDENSER FAN
S
C
L1
COOLING T'STAT
R
COMPRESSOR
115V
N
G
Wiring Diagram 8100-EF, 8100-EFN
CONDENSER FAN
S
C
ON/OFF SWITCH
L1
COOLING T'STAT
R
COMPRESSOR
120V
N
G
Wiring Diagram N8200 & N8200G
ON/OFF SWITCH
L1
CONDENSER FAN
S
C
R
COMPRESSOR
115V
N
G
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
17
N8000 Series Drop-In Installation and Operation Manual
Wiring Diagram N8630
CONDENSING UNIT
COOLING
THERMOSTAT
M
120V-1PH-3KW HEATER
3-WAY
SWITCH
HEATER #1
CONTACTOR
L1
HEATER #1
THERMOSTAT
HEATER #1
LIMIT SWITCH
N
Wiring Diagram N8643 & N8656
CONDENSING UNIT
COOLING
THERMOSTAT
M
3-WAY
SWITCH
HEATER #1
CONTACTOR
L1
L2
HEATER #1
THERMOSTAT
HEATER #1
LIMIT SWITCH
N
240V-1PH-5KW HEATER
Delfield
™
18
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Wiring Diagram N8669 & N8681
L1
L2
N
(2) 240V-1PH-5KW HEATERS
3-WAY
SWITCH
CONDENSING UNIT
COOLING
THERMOSTAT
M
HEATER #1
HEATER #1
CONTACTOR
HEATER #2
HEATER #2
CONTACTOR
THERMOSTAT
HEATER #1
LIMIT SWITCH
HEATER #2
LIMIT SWITCH
Wiring Diagram N8800 208/230V
LI
THERMOSTAT
Delfield
™
G
L2
DOUBLE POLE
THERMOSTAT ON
MODELS N8873 &
N8887 ONLY
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
19
N8000 Series Drop-In Installation and Operation Manual
Wiring Diagram N8700-D, N8700N & N8700-R
PILOT LIGHT
(FURNISHED)
H1
1000 W - 120V
OR 1000/1222 W 208-230 V
HEATING ELEMENT
P
L1
L2
H2
LINE
WIRES
TO ADDITIONAL
FOOD WARMERS
INFINITE CONTROL
WITH “OFF”
POSITION
AMPERES IN LINE WIRES
# OF
WARMERS
1
120V,
1 PHASE
8.3
2
3
4
208V,
1 PHASE
4.8
230V,
1 PHASE
5.3
16.7
9.6
10.6
25
33.3
14.4
19.2
15.9
21.3
14.4/15.9
14.4/15.9
14.4/15.9
19.2/21.3
19.2/21.3
14.4/15.9
5
24
26.6
19.2/21.3
19.2/21.3
6
28.8
31.3
24/26.1
28.8/31.3
28.8/31.3
28.8/31.3
L1
G
L1
208-230V, 3 PHASE
L2
L3
L2
30A SWITCH
(OPTIONAL)
L1
L2
G
L3
20A, 3–POLE SWITCH
(OPTIONAL)
HA–1
HA–1
HA–2
HA–2
ALL WIRING
MINIMUM 14 AWG
250C
HA–3
HA–3
HA–4
HA–4
HA–5
HA–5
HA–6
HA–6
HA = HEATER ASSEMBLY
Standard Single Phase
HA = HEATER ASSEMBLY
Optional Three Phase
Delfield
™
20
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Drop In Louver Panel
25”
13”
Louver part #359-411-0003
Cutout dimension is 11” x 22” (27.9 cm x 55.9 cm).
Miscellaneous Parts 8000 SERIES
Delfield Part #
265-AXE-0000 243-ALS-0032 243-AB0-0001 3234242 1701273 Description
Divider bar, 2.00” x 20.93”
Divider bar, 13.00” x .90”
Divider bar, 21.00” x .90”
Plastic drain
Trim gasket (sold by foot)
Delfield
™
Cap Tube Chart - R134A Refrigerant
Model Number
N8118B
N8130B
N8143B
N8144-BR
N8146NB
N8156B
N8159-BR
N8168NB
N8169B
N8176-BR
N8181B
N8194-BR
Cap Tube Size/Length
.036ID x 72”
.036ID x 72”
.036ID x 72”
.036ID x 72”
.042ID x 120”
.042ID x 120”
.036ID x 72”
.042ID x 120”
.042ID x 120”
.042ID x 120”
.054ID x 110”
.042ID x 120”
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
21
N8000 Series Drop-In Installation and Operation Manual
Replacement Parts N8100-FA
8
7
9
6
1
2
5
3
10
4
11
12
13
14
15
16
17
Key
Description
1
Upright diffuser
2
Air deflector
3
Coil
4
Expansion valve
5
Coil assembly cover
6
Fan assembly cover
7
Adapter bar
8
Perforated pan clip
9
Black airflow extrusion
10 Cover support bracket
11
Fan guard
12
Fan blade
13
Fan motor
14
Fan bracket
15 Plexiglas end cap
16 S/S thumb screw
17
Cond. Unit
—
Timer
—
Pressure Control
—
Rocker switch
N8131-FA
N8144-FA
N8157-FA
N8169-FA
N8182-FA
2-PAN3-PAN4-PAN5-PAN6-PAN
226-0V3-0030226-0V3-0031226-0V3-0032226-0V3-0033226-0V3-0034
226-A9L-0030226-A9L-0031226-A9L-0032226-A9L-0033226-A9L-0034
35100863510086351008635100863510086
35162733516273351627335162733516273
019-0V0-0030
019-0V0-0038
019-0V0-0032
019-0V0-0033
019-0V0-0034
226-0V1-0030
226-0V1-0031
226-0V1-0032
226-0V1-0033
226-0V1-0034
243-AB0-0001243-AB0-0001243-AB0-0001243-AB0-0001243-AB0-0001
270-0V5-0030
270-0V5-0031
270-0V5-0032
270-0V5-0033
270-0V5-0034
316-991-0030
316-991-0031
316-991-0032
316-991-0033
316-991-0034
226-0V2-0030
226-0V2-0030
226-0V2-0030
226-0V2-0030
226-0V2-0030
35161733516173351617335161733516173
35161723516172351617235161723516172
21626912162691216269121626912162691
031-264-0000031-264-0000031-264-0000031-264-0000031-264-0000
091-0XL-0030
091-0XL-0030
091-0XL-0030
091-0XL-0030
091-0XL-0030
9321541
9321541
9321541
9321541
9321541
000-BN5-0030000-BN5-0035000-BN5-0035000-BN5-0036000-BN5-0036
21943452194345219434521943452194345
21939272193927219392721939272193927
21901542190154219015421901542190154
Delfield
™
22
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Condensing Unit 1/4 H.P. R404a Low
8100-EF Series, 8100-EFN Series, N8131-FA, N8231, N8231G, N8245, N8245G, N8259, N8273, N8630, N8643, N8656, N8669
Key
-
-
1
2
3
3
4
5
5
6
7
8
9
10
Delfield Part #
000-BN5-0030 000-BN5-003J
026-C58-0030
3516457
2162717
2162720
2160020
3526999
3527013
2194787
3516444
3516322
075-231-0030
3516454
Description
Condensing Unit Assembly, 115V
Condensing Unit Assembly, 220V/50Hz
Shroud, Condenser Coil
Blade, Fan, 7.25”
Motor, fan, 9W, 115V
Motor, fan, 9W, 230V
Guard, Fan, 7.25”
Compressor, NF5.5CLX, 115V/60Hz, Danfoss
Compressor 220/50Hz, Danfoss
Capacitor, Start 280MFD
Compressor relay and overload, NF5.5CLX
Filter-dryer, (2) inlet .25”
4
Pan, condensate
2
3
Condenser Coil
5
1
Miscellaneous Parts Not Included in Condensing Unit
-
2194099
15 Amp switch, 120V
-
2194400
15 Amp switch, 220V
-
2183348
Cord/plug assembly
-
3516225
Expansion valve
6
7
8
9
10
Condensing Unit Assembly 1/3 H.P. R404a, Low, N8259G, N8287, N8681
Key
-
-
1
2
3
3
4
5
5
6
7
8
9
10
11
12
Delfield Part #
Description
000-BN5-003G Condensing Unit Assembly, 115V
000-BN5-003M
Condensing Unit Assembly, 220V/50Hz
026-C58-0030
Shroud, Condenser Coil
3516457
Blade, Fan, 7.25”
2162717
Motor, fan, 9W, 115V
2162720
Motor, fan, 9W, 230V
2160020
Guard, Fan, 7.25”
3527000
Compressor, NF7.0. 115V/60Hz, Danfoss
3527012
Compressor, 220V/50Hz Danfoss
3516324
High pressure switch
2194788
Capacitor, Start 320MFD
3516438
Compressor relay and overload, NF7CLX
3516322
Filter-dryer, (2) inlet .25”
1
3516458
Receiver tank
075-231-0030
Pan, condensate
3516454Condenser Coil
5
4
2
3
6
7
Miscellaneous Parts Not Included in Condensing Unit
-
3516225
Expansion valve
-
2194099
15 Amp switch, 120V
-
2194400
15 Amp switch, 220V
-
2183348
Cord/plug assembly
8
9
10
11
12
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
23
N8000 Series Drop-In Installation and Operation Manual
Condensing Unit Assembly 1/2 H.P. R404a, Low, N8273G
Key
-
-
1
2
3
4
4
5
6
6
7
8
9
10
11
Delfield Part #
000-BN5-0033
000-BN5-003N
026-C58-0031
3516554
2160019
2162716
2162721
3516324
3527001
3527011
3516322
2194789
3516441
3516459
3516455
Description
Condensing Unit Assembly, 115V
Condensing Unit Assembly, 220V/50Hz
Shroud, 1/2 HP Condenser Coil
Blade, Fan, 9.00”, 5-pedal
Guard, Fan, Condenser, Upright
Motor, Fan, 16W, 115V
Motor, Fan 16W, 230V
High Pressure Switch
Compressor, SC12CLX.2,115V/60Hz, Danfoss
Compressor, 220V/50Hz, Danfoss
Filter-dryer, (2) inlet .25”
Capacitor, Start 240MFD
Compressor relay, SC12CLX.2
Receiver
Condenser Coil
6
7
5
4
3
2
1
8
9
Miscellaneous Parts Not Included in Condensing Unit
-
3516225
Expansion valve
-
2194099
15 Amp switch, 120V
-
2194400
15 Amp switch, 220V
-
2183348
Cord/plug assembly
10
11
Delfield
™
24
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Narrow Base Condensing Unit Assembly 1/5 H.P. R134A, Low
N8118B, N8130B, N8143B, N8144-BR, N8146NB, N8159-BR, N8168NB
Key
1
2
2
3
4
5
6
7
7
8
9
-
-
Delfield Part #
2183300
3526694
3526718
3516047
024-ADB-0040
031-264-0000
3516172
2162691
2162692
026-ANM-0030
3516067
3516191
2194400
Description
Harness, wire, power cord, 8100
Compressor, 1/5 h.p.,115v/60hz
Compressor, 1/5 h.p., 220v/50hz
Cold Control
Compressor stand
Bracket, fan motor, blower coil
Blade, fan, 5.56, CCW, Lexan, clear
Motor, fan, 115v, 50/60, UPPCO/bay
Motor, fan, 230V, 50/60, UPPCO/bay
Fan baffle
Coil, condenser, 9 x 10, R-134a, 8100
Filter dryer
15 Amp switch, 220V
1
2
3
4
8
5
7 6
9
Narrow Base Condensing Unit Assembly N8156B, N8169B, N8176-BR, N8181B, N8194-BR
Key
Delfield Part #
Description
1
2183300
Harness, wire, power cord
2
3526703
Compressor, 1/3HP, 115/60, R134A, N8181B
2
3526695
Compressor, 1/4 h.p.,115v/60hz, N8156B,
N8169B, N8176-BR, N8194-BR
2
3526719
Compressor, 1/4 h.p., 220v/50hz
3
3516047
Cold control
4
024-ADB-0041
Stand, compressor
5
2194013
Fan assembly, condenser, 8” blade, 115V
5
2162689
Fan assembly, condenser, 8” blade, 220V
6
026-ANM-0033
Baffle, fan
7
3516067
Coil, condenser, 9x10, R134A
-
3516191
Filter dryer
-
2194400
15 Amp switch, 220V
1
2
3
4
5
6
7
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
25
N8000 Series Drop-In Installation and Operation Manual
Condensing Unit Assembly 1/2 H.P. N8144-FA, N8157-FA
Key Delfield Part #
-
000-BN5-0035 1
026-C58-0031
2
3516554
3
2160019
4
2162716
5
3516462
6
3527026
7
3516331
8
3516322
93516459
10
075-231-0031
11
3516455
Description
Condensing Unit Assembly
Shroud, 1/2 HP condenser coil
Blade, fan 9.00”, 5 pedal
Guard, fan, condenser, upright
Motor, fan, 16W, 115V
Capacitor, start, assembly
Compressor, SC12MLX, 115V/60Hz, Danfoss
High pressure switch
Filter dryer, (2) inlet, .25”
Receiver
Pan, condensate
Coil, 1/2 HP condensing
7
6
5
4
3
2
1
8
8
10
11
Condensing Unit Assembly 3/4 H.P. N8169-FA, N8182-FA
Key
-
1
2
3
4
5
6
7
-
-
-
Delfield Part #
000-BN5-0036
026-C58-0032
2160019
3516442
3527021
3516322
3516360
3516456
075-231-0031
3516433
2162716
Description
Condensing Unit Assembly
Shroud, 3/4 HP condenser coil
Guard, fan, condenser, upright
Capacitor, start, run, assembly
Compressor, SC18MLX, 115V/60Hz, Danfoss
Filter dryer, (2) inlet, .25”
Tank, receiver
Coil, condenser, 3/4 HP
Pan, condensate
Blade, fan 25º, 10”, CW, upright
Motor, fan, 16W, 115V
4
3
1
2
5
6
7
Delfield
™
26
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Food Well Assembly With Thermostat control N8600
2
1
10
9
8
7
6
5
4
3
For models N8600
Key
1
1
2
3
4
5
6
7
8
9
10
Delfield Part #
2194940
2194942
026-AO6-0041
372-ANQ-003D
2193979
372-ANS-0001
2194190
2194202
3234556
2194185
3516047
Delfield
™
Description
Immersion heater 120V, 1Ph 3KW
Immersion heater 240V 1Ph 5KW
Box, control, galv, 8600 series
Front, collar, mounting, 8600
Switch, 3 position, 30Amp
Cover, control box, 8700 series
Light, pilot, 125V, red
Thermostat, electric (heated)
Knob, thermostat control (heated)
Contactor, relay 30 Amp 120V
Temperature control (cold)
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
27
N8000 Series Drop-In Installation and Operation Manual
Food Well Assembly With Infinite Control N8700
For models N8700D, N8700N, N8700ND, N8700R
Key
1
2
3
4
5
6
6
7
7
-
-
-
Delfield Part #
3434703
2194335
026-103-0002
3434663
026-061-0001
2194007
2194006
000-BQ9-Z0000
000-BQ9-Z0001
3234557
2194110
2194107
Description
Insulation, fiberglass, 9” x 48”
Thermostat, non-adjustable, 480˚F
Bottom cover
Insulation, blanket, 24” wide
Plate, deflector, DFW, with or without drain
Element, heating, 208/230v, 1000/1222w
Element, heating, 120v
Well, hot food, with drain
Well, hot food, without drain
Knob, infinite control
Control, infinite, 240v, 14a
Control, infinite, 120v
4
3
5
1
2
1
6
7
Food Well Assembly With Thermostat Control N8800
For models N8831, N8859, N8873, N8887
Key
1
2
2
3
3
4
-
-
Delfield Part #
3234556
2193984
2194012
2194007
2194006
026-061-0001
3434704
3434664
Description
Knob, thermostat control
Thermostat 30A, N8873. N8887
Thermostat, 25A, N8831, N8845, N8859
Element, heating, 208/230v, 1000/1222w
Element, heating, 120v, 1000w
Plate, deflector, DFW, with drain
Insulation, fiberglass, 1” thick
Insulation, fiberfrax, 1” thick
4
1
2
3
Delfield
™
28
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special
coverage.
•A maximum of 1-hour is allowed to diagnose a defective component.
•A maximum of 1-hour is allowed for retrieval of parts not in stock.
•A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
•Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight
damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless preapproved with a Service Work Authorization from Delfield. You must submit the number with the service claim.
Labor Of 1-Hour Is Allowed To Replace:
•Compressor Start Components and Overload Protector
•Condenser Fan Motor and Blade
•Hi-limit/Thermal Protector Switch
•Solenoid Coil
• Condensate Element
• Contactor/Relay
• Infinite Switch
• Thermostat
Labor Of 2 Hours To Replace:
•Heating Element
•Solenoid Valve
• Locate/Repair Leak
Labor Of 3 Hours To Replace:
•Capillary Tubing
•Expansion Valve
• Condenser
Labor Of 4 Hours To Replace:
•Compressor
This includes recovery of refrigerant and leak check.
$55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor
fittings, solder, brazing rod, nitrogen, or similar fees.)
Refrigerants:
•R134A A maximum of $5.00/lb. or 31/oz. will be reimbursed.
•R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed.
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
29
N8000 Series Drop-In Installation and Operation Manual
Standard One Year Limited Warranty (One year parts, 90 days labor)
The Delfield Company (“Delfield”) warrants to the Original
Purchaser of the Delfield product (herein called the “Unit”) that
such Unit, and all parts thereof, will be free from defects in
material and workmanship under normal use and service for a
period of one (1) year from the date of shipment of the Unit to
the Original Purchaser or, if the Original Purchaser returns
the warranty card completely filled out including the date of
installation within thirty (30) days of receipt of the Unit, one
(1) year from the date of installation. During this one year
warranty period, Delfield will repair or replace any defective part
or portion there of returned to Delfield by the Original Purchaser
which Delfield determines was defective due to faulty material
or workmanship. The Original purchaser will pay all labor,
crating, freight and related costs incurred in the removal of the
Unit of defective component and shipment to Delfield, except
that during a period of either ninety (90) days from the date of
shipment of the Unit to the Original Purchaser or, if the Original
Purchaser returns the warranty card completely filled out
including the date of installation within thirty (30) days of receipt
of the Unit, ninety (90) days from the date of installation Delfield
will pay all related labor costs. Delfield will pay the return costs
if the Unit or part thereof was defective.
The term “Original Purchaser” as used herein means that
person, firm, association, or corporation for whom the Unit was
originally installed.
This warranty does not apply to any Unit or part thereof that has
been subjected to misuse, neglect, alteration, or accident, such
as accidental damage to the exterior finish, operated contrary
to the recommendations specified by Delfield; or repaired or
altered by anyone other than Delfield in any way so as to, in
Delfield’s sole judgement, affect its quality or efficiency. This
warranty does not apply to any Unit that has been moved from
the location where it was originally installed. This warranty
also does not cover the refrigerator drier or the light bulbs
used in the Unit. The warranty is subject to the user’s
normal maintenance and care responsibility as set forth
in the Service and Installation Manual, such as cleaning
the condenser coil, and is in lieu of all other obligations
of Delfield. Delfield neither assumes, nor authorizes any
other person to assume for Delfield, any other liability in
connection with Delfield’s products.
Removal or defacement of the original Serial Number or Model
Number from any Unit shall be deemed to release Delfield from
all obligations hereunder or any other obligations, express or
implied.
Parts furnished by suppliers to Delfield are guaranteed by
Delfield only to the extent of the original manufacturer’s express
warranty to Delfield. Failure of the Original Purchaser to
receive such manufacturers warranty shall in no way create
any warranty, expressed or implied, or any other obligation or
liability on Delfield’s part in respect thereof.
If shipment of a replacement part is requested prior to the
arrival in the Delfield factory of the part claimed to be defective,
the Original Purchaser must accept delivery of the replacement
part on a C.O.D. basis, with credit being issued after the part has
been received and inspected at Delfield’s plant and determined
by Delfield to be within this warranty.
Under no condition does this warranty give the Original
Purchaser the right to replace the defective Unit with a complete
Unit of the same manufacturer or of another make. Unless
authorized by Delfield in writing, this warranty does not permit
the replacement of any part, including the motor-compressor, to
be made with the part of another make or manufacturer.
No claims can be made under this warranty for spoilage of any
products for any reason, including system failure.
The installation contractor shall be responsible for building
access, entrance and field conditions to insure sufficient
clearance to allow any hood(s), vent(s), or Unit(s) if necessary,
to be brought into the building. Delfield will not be responsible
for structural changes or damages incurred during installation
of the Unit or any exhaust system.
Delfield shall not be liable in any manner for any default or delay
in performance hereunder caused by or resulting from any
contingency beyond Delfield’s control, including, but not limited
to, war, governmental restrictions or restraints, strike, lockouts,
injunctions, fire, flood, acts of nature, short or reduced supply
of raw materials, or discontinuance of the parts by the original
part manufacturer.
Except as provided in any Additional Four Year Protection
Plan, if applicable, and the Service Labor Contract, if
applicable, the foregoing is exclusive and in lieu of all other
warranties, whether written or oral, express or implied. This
warranty supersedes and excludes any prior oral or written
representations or warranties. Delfield expressly disclaims
any implied warranties of merchantability, fitness for a
particular purpose or compliance with any law, treaty, rule
or regulation relating to the discharge of substances into
the environment. The sole and exclusive remedies of any
person relating to the Unit, and the full liability of Delfield
for any breach of this warranty, will be as provided in this
warranty.
Other than this Delfield Standard One Year Limited Warranty,
any applicable Delfield Additional Four Year Protection Plan
or applicable Delfield Service Labor Contract, the Original
Purchaser agrees and acknowledges that no other warranties
are offered or provided in connection with or for the Unit or any
other part thereof.
In no event will Delfield be liable for special, incidental or
consequential damages, or for damages in the nature of
penalties.
Delfield
™
30
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
®
N8000 Series Drop-In Installation and Operation Manual
Additional Four Year Protection Plan
Delfield Model# Serial #
(for Motor-Compressor only)
Installation
Date
In addition to the Standard One Year Warranty on the MotorCompressor contained in the above listed Delfield product
(the “Unit”), The Delfield Company (“Delfield”) also agrees to
repair, or exchange with similar or interchangeable parts in
design and capacity at Delfield’s option, the defective MotorCompressor contained in the Unit (the “Motor-Compressor),
or any part thereof, for the Original Purchaser only, at any
time during the four (4) years following the initial one (1) year
period commencing on the date of installation for the Original
Purchaser. Failure of the Original Purchaser to register
the registration card containing the Original Purchasers
name, address, date of installation, model number and
serial number of the Unit containing the Motor-Compressor
within 30 days from the date of installation shall void this
warranty. This additional warranty is only available if the MotorCompressor is inoperative due to defects in material or factory
workmanship, as determined by Delfield in its sole judgement
and discretion. The Original Purchaser shall be responsible for
returning the defective Motor-Compressor to Delfield prepaid,
F.O.B. at the address shown on the back cover of this manual.
The term “Original Purchaser” as used herein means that
person, firm, association, or corporation for whom the Unit was
originally installed.
The term “Motor-Compressor” as used herein does not include
unit base, air or water cooled condenser, receiver, electrical
accessories such as relay, capacitors, refrigerant controls, or
condenser fan/motor assembly. This warranty does not cover
labor charges incidental to the replacement of parts. This
warranty further does not include any equipment to which said
condensing unit is connected, such as cooling coils, temperature
controls or refrigerant metering devices. This warranty shall
be void if the Motor-Compressor, in Delfield’s sole judgement,
has been subjected to misuse, neglect, alteration or accident,
operated contrary to the recommendations specified by the Unit
manufacturer, repaired or altered by anyone other than Delfield
in any way so as, in Delfield’s sole judgment, to affect its quality
or efficiency or if the serial number has been altered, defaced or
removed. This Warranty does not apply to a Motor-Compressor
in any Unit that has been moved from the location where it
was originally installed. The addition of methyl chloride to the
condensing unit or refrigeration system shall void this warranty.
Delfield
™
General Conditions
Delfield shall not be liable in any manner for any default or delay
in performance hereunder caused by or resulting from any
contingency beyond Delfield’s control, including, but not limited
to, war, governmental restrictions or restraints, strike, lockouts,
injunctions, fire, flood, acts of nature, short or reduced supply
of raw materials, or discontinuance of any part or the MotorCompressor by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one
(1) Motor-Compressor by us during the four (4) year period.
Delfield shall replace the Motor-Compressor at no charge.
This warranty does not give the Original Purchaser of the MotorCompressor the right to purchase a complete replacement
Motor-Compressor of the same make or of another make. It
further does not permit the replacement to be made with
a Motor-Compressor of another kind unless authorized by
Delfield. In the event Delfield authorizes the Original Purchaser
to purchase a replacement Motor-Compressor locally, only the
wholesale cost of the Motor-Compressor is refundable.
Expressly excluded from this warranty are damages resulting
from spoilage of goods.
Except as provided in any applicable Standard One Year
Limited Warranty or applicable Service Labor Contract, the
foregoing is exclusive and in lieu of all other warranties,
whether written or oral, express or implied. This Warranty
supersedes and excludes any prior oral or written
representations or warranties. Delfield expressly disclaims
any implied warranties of merchantability, fitness for a
particular purpose or compliance with any law, treaty, rule
or regulation relating to the Motor-Compressor, and the full
liability of Delfield for any breach of this warranty, will be as
provided in this warranty.
Other than any applicable Delfield Standard One year Limited
Warranty, this Delfield Additional Four Year Protection Plan and
any applicable Delfield Service Labor Contract, the Original
Purchaser agrees and acknowledges that no other warranties
are offered or provided in connection with or for the MotorCompressor or any part thereof.
In no event will Delfield be liable for special, incidental or
consequential damages, or for damages in the nature of
penalties.
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
31
Delfield
™
®
Covington, TN
Mt. Pleasant, MI
Thank you for choosing Delfield!
Help is a phone call away. Help our team of professional, courteous
customer service reps by having your model number and serial number
available at the time of your call (800) 733-8829.
Model:_____________________ S/N: ____________________
Installation Date:_____________
For a list of Delfield’s authorized parts depots,
visit our website at www.delfield.com.
Delfield
™
®
980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (989) 773-7981 or (800) 733-8829 • Fax (989) 773-3210 • www.delfield.com
Delfield reserves the right to make changes in design or specifications without prior notice. ©2012 The Delfield Company. All rights reserved. Printed in the U.S.A.
DM8000 01/12
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement