Electrolux AOW101EABU (260573) Service Manual
PDF
Dokument
Reklama
Reklama
Electrolux Air-O-Speed Oven: Parameter List firmware 130 LW 10 1/1 1 GAS Define if the oven is GAS heated (1) or ELECTRIC heated (0) Default Description Masurem ent unit Label Par N° ELT A Range regolaz. Min Max 0 1 0 4 0 0 30 0 0 1 0 0 1 0 1 0 1 0 Type of oven: 0: LW 6 1/1 1: LW 10 1/1 2: LW 20 1/1 3: LW 10 2/1 2 APPM 4: LW 20 2/1 0 1 Languages: 0 = English 1 = Italian 2 = German 3 = French 4 = Spanish 5 = Dutch 6 = Swedish 7 = Danish 8 = Portuguese 9 = Greek 10 = Finnish 11 = Norwegian 12 = Estonian 13 = Lithuanian 14 = Latvian 15 = Polish 16 = Czech 17 = Slovakian 18 = Slovenian 19 = Hungarian 3 LAnG 4 FAHr Temperature unit 0 = Celsius; 1= Fahrenheit Flag to define the time format 5 C12H 0 = 24h; 1 = 12h AM/PM Flag to enable cavity temperature displaying adjustment 6 cort 7 LAMb 0 = Disable; 1 = Enable 0 Nota1 Presence of lambda probe 0 = Not installed; 1 = Installed 1 Type of meat probe 8 6Prb 9 NO N 0 = Singlepoint; 1 = Multipoint 1 0 1 0 1 Power supply type: 0 = with neutral; 1 = without neutral 0 Nota2 Flag to disable the automatic cleaning cycles 10 dCLn 0 = Enable; 1 = Disable 0 0 1 11 ALIE Flag to enable the detergent and rinse aid external tanks level sensors 0 0 1 12 FCLn Mandatory cleaning minutes countdown counter 0 -120 120 13 PAUt Flag to enable automatic program (clean excluded) 1 0 1 0 0 2 1 0 1 min Starting environment after oven switch on 0: MANUAL 1: AUTOMATIC 14 MODO 2: PROGRAM Flag manual humidifier MHUM 0 = Disable; 1 = Enable 16 IrdA 0 = Disable; 1 = Enable 0 0 1 17 PHMN Flag to enable the cavity preheating in manual mode 1 0 1 0 0 1 0 0 1 0 0 1 15 Flag that enables infrared communication Flag to enable Peak Power Management 18 PPM 0 = Not active; 1 = Active Flag to enable the DEMO mode. 19 dEMO 0 = Not active; 1 = active Flag to disable the oven stops when door is open in convection and combi mode 20 dSod 0 = Disable; 1 = Enable Flag to enable starting of cooking closing the door 21 AbSP 0 = Disable; 1 = Enable 0 0 1 22 Hdut Flag to enable heaters duty-cycle 1 0 1 1 0 1 Flag to enable the changing from automatic to manual mode 23 AbAM 0 = Disable; 1 = Enable Flag to disable preheating of boiler of boiler when the oven is in stand-by mode 24 dSPS 0 = Disable; 1 = Enable 25 SPHb Preheating temperature of the boiler 26 Sbc Cooling temperature set for electronic board ventilation 27 HAbP Steam condenser engagement in "hot air" mode (lev. B ovens) and all cycles (lev. A ovens) 28 StbP Steam condenser engagement in "steam/boiler" mode in lev. B ovens 29 thMA Defines the max. temperature limit for the manual injection of water trMA Defines the max. temperature for water injection during cooling phase 31 trMn Defines the min. temperature for water injection during cooling phase 32 tCMS Maximum temperature for no limitation on phase length 33 dutM 34 30 0 0 1 °C 85 0 100 °F 185 32 212 °C 35 0 55 °F 95 32 131 °C 90 50 300 °F 194 122 572 °C 80 50 100 °F 176 122 212 °C 250 0 300 °F 482 32 572 °C 180 0 300 °F 356 32 572 °C 40 0 300 °F 104 32 572 °C 250 0 300 °F 482 32 572 Maximum length of a phase with cavity temperature over tCMS min 20 1 900 HUon ON phase of the humidifier with combi cycle between 50 and 100 °C (122 and 212 °F) s/10 5 0 250 35 tbon Timeout for water level probe alarm (0 = disabled control) s 0 0 2400 36 hbol Boiler hour counter h/4 0 0 9999 37 dbon Delay for boiler drain h/4 1 0 999 °C 50 0 100 38 tcdb Max. water temperature for boiler drain °F 122 32 212 39 dtSb Delay for fast filling during opening of boiler drain valve s 255 0 255 40 SEAL Altitude above sea level m 0 0 4000 Note3 41 OCA1 Offset of first cavity temperature probe 42 SbyP Bypass temperature with max. cooking cavity steam temperature (calibration) 43 HbYP Max. humidity value to stop the boiler 44 OLbd Lambda probe calibration (dry point) only level A. 45 SPHF Boiler temperature set for fermentation cycle Boiler temperature that detects the presence of scale 46 SInC 47 cot Max. cooking chamber overheating (EtuC alarm) 48 bot Max. steam generator overheating (EtuB alarm) °C 0 °F 32 -10 10 14 50 °C °F 100 80 110 212 176 230 % 98 80 100 76,29 V 0 -999 999 °C 97 0 130 °F 97 32 266 °C 115 0 150 °F 239 32 302 °C 320 250 340 °F 608 482 644 °C 125 90 200 °F 257 194 392 0 0 4 0 0 7 Nota4 Activation of cavity motor thermal protection 0 = No alarm; 1 = Upper motor; 2 = Lower motor; 3 = All motor 49 ALFn 4 = Boiler water level probes error !" # $ !" % !" & !"!" 50 almg 51 MWTH 0: no test magnetron A/5 20 0 200 52 MWdu Magnetron test sequence phase duration s/10 100 0 250 53 cu Parameter q of SCELOFF formula (fuzzy logic) -1 -20 20 54 EMME Parameter m of SCELOFF formula (fuzzy logic) 27 0 50 Magnetron current failure threshold 55 PI Parameter p of SCELON formula (fuzzy logic) 0 -40 40 56 I Parameter i of SCELON formula (fuzzy logic) 2 -10 10 dton Max. cooking chamber temperature derivative value to switch on heating elements (fuzzy logic) -1 -20 0 dtoF Max. cooking chamber temperature derivative value to switch off heating elements (fuzzy logic) 2 0 20 0 0 3 57 58 HACCP mode: 0 = None 1 = Basic 2 = Advanced 59 HCCP 3 = Monitor RS485 bit rate 0 = 1200 baud 1 = 2400 baud 2 = 4800 baud 3 = 9600 baud 4 = 19200 baud 5 = 57600 baud 60 bAud 6 = 115200 3 0 6 61 Addr RS485 address 1 1 250 62 tPrn (0 = no print). s 30 0 250 63 hair Hot air hour counter h 0 0 9999 64 hStM Steam hour counter h 0 0 9999 65 hcMb Combi hour counter h 0 0 9999 66 hMW Microwave hour counter h/4 0 0 9999 % 20 0 100 % 50 0 100 Print frequency PWM value at start of cavity burners G20 G25 G30 67 StcA GPL PWM value at half power of cavity burners G20 G25 G30 68 hAcA GPL PWM value at full power of cavity burners G20 G25 G30 69 FucA GPL % 75 0 100 % 20 0 100 % 50 0 100 % 75 0 100 PWM value at start of boiler burners G20 G25 G30 70 Stbo GPL PWM value at half power of boiler burners G20 G25 G30 71 hAbo GPL PWM value at full power of boiler burners G20 G25 G30 72 Fubo GPL 73 CLt1 Length of detergent injection (phases A and B). s/10 30 1 250 74 CLt2 Length of detergent+water injection (phases A and B). s/10 20 1 250 75 CLt3 Length of rinse aid+water injection (phase C). s/10 50 1 250 76 CLt4 Length of water injection C). s/10 10 1 250 77 MANU Flag to enable manual mode 1 0 1 78 AUTO Flag to enable automatic mode 1 0 1 79 PRRD Flag to enable program reading 1 0 1 80 PRWR Flag to enable program writing 1 0 1 (phase Define if the modification of store program is disable 81 nMod 0 = Enable; 1= Disable 0 0 1 82 PFAC Flag to enable factory program (clean excluded) 1 0 1 83 chr1 Password character 1 32 Nota5 0 255 84 chr2 Password character 2 32 Nota5 0 255 85 chr3 Password character 3 32 Nota5 0 255 86 chr4 Password character 4 32 Nota5 0 255 87 chr5 Password character 5 32 Nota5 0 255 88 chr6 Password character 6 32 Nota5 0 255 89 chr7 Password character 7 32 Nota5 0 255 90 chr8 Password character 8 32 Nota5 0 255 91 dbFd Food database index 0 Nota2 0 9 Note 1: set this parameter to 1 after bypass calibration and cavity offset (parameter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
/
Stáhnout
Jen přátelské upozornění. Dokument si můžete prohlédnout přímo zde. Ale co je nejdůležitější, naše AI si ho již přečetla. Dokáže složité věci vysvětlit jednoduchými slovy, zodpovědět vaše otázky v jakémkoli jazyce a pomoci vám rychle se orientovat i v těch nejdelších nebo nejsložitějších dokumentech.
Reklama