313AAV/JAV Plus 80x
4--WAY MULTIPOISE
INDUCED--COMBUSTION GAS FURNACE
INPUT CAPACITIES: 45,000 THRU 135,000 Btuh
Product Data
STANDARD FEATURES
S ECM blower motor included
S Noise elimination combustion system
S SmartEvapt can lower the humidity level in the home by
nearly 10%
S Four--position furnace: Upflow, Horizontal Right,
Horizontal Left, Downflow
Thirteen different vent options
S Compact design only 33--1/3 in. (847 mm) tall
S High--Efficiency Media Filtration Cabinet included
S Washable filter included
A08288
THE BRYANT Plus 80x GAS FURNACE
The Plus 80x Deluxe 4--Way Multipoise Gas Furnace offers
outstanding features in an 80% AFUE furnace.
Deluxe features include: an ECM motor which enhances SEER
performance up to 1.5 points*, a third fan relay for discrete
continuous fan speed, the ability to change continuous fan speeds
from the thermostat (Fan on Plust), dehumidify mode, standard
Media Filter Cabinet, fault code storage, and more. The Plus 80x
is very quiet thanks to a new combustion design that eliminates
noise, rather than just muffle or box it in. Applications are easy
with 4--way multipoise design, through--the--furnace downflow
venting, 13 different venting options, and a door designed for easy
service access. An inner blower door is provided for tighter sealing
in sensitive applications. The 313JAV is approved for use in Low
NOx Air Quality Management Districts.
*as compared to the Air Conditioning Heating and Refrigeration
Institute’s standard coil--only ratings when paired with selected
Bryant evaporator coils.
S Microprocessor based “smart” control center
“Fan on Plust “--Continuous Fan speed adjustable from
thermostat
Adjustable heating air temperature rise
Dehumidify mode
LED diagnostics, non--volatile fault code memory, and self--test
feature
On--board fuse for transformer protection
S Patented blocked vent safeguard to ensure proper furnace
venting
S Insulated blower compartment
S HYBRID HEAT® Dual Fuel System compatible
S All models are chimney friendly when used with accessory
vent kit
S Perfect Lightt Igniter
S Residential installations eligible for consumer financing
through the Comfort Credit Program
1
FURNACE COMPONENTS
INDUCER MOTOR
ASSEMBLY
VENT ELBOW
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
PRESSURE
SWITCH
DRAFT
SAFEGUARD
SWITCH
FLAME SENSOR
FLUE
COLLECTOR
BOX
GAS VALVE
GAS MANIFOLD
MANUAL RESET
LIMIT SWITCHES
GAS BURNER
HOT SURFACE
IGNITER
BLOWER DOOR
SAFETY SWITCH
313AAV/JAV
CONTROL
BLOWER AND
MOTOR
CAPACITOR/POWER
CHOKE (WHERE USED)
RATING PLATE
NOT SHOWN
(LOCATED ON
BLOWER DOOR)
A02259
NOTE: The 313AAV/JAV Furnaces are factory shipped for use with natural gas. These furnaces can be field--converted for propane gas
with a factory--authorized and listed accessory conversion kit.
58DLA/DLX
A02169
A02169
HEAT EXCHANGER
A08063
CONTROL BOARD
2
A02170
INDUCER BLOWER
BRYANT ACCESSORIES
A97432
Available in programmable and
non-programmable models,
Bryant thermostats maintain a
constant, comfortable temperature level in the home.
For the ultimate in home comfort,
Bryant’s 2, 4, and 8-zone systems
allow temperature control of individual “zones” of the home. This is
accomplished through a series of
electronic dampers and
remote room sensors. The
4-zone system is shown.
C04009
MECHANICAL
OR ELECTRONIC
AIR CLEANER
Cleans the air of smoke, dirt, and
many pollens commonly found.
Saves decorating and cleaning
expenses by keeping carpets,
furniture, and drapes cleaner.
Electronic air cleaner is shown.
A01484
MODEL HUMCCLFP
HUMIDIFIER
By adding moisture to winter-dry
air, a Bryant humidifier can often
improve comfort and keep
furniture, rugs, and draperies in
better condition. Moisturizing
household air also helps to retain
normal body heat and provides
comfort at lower temperatures.
313AAV/JAV
CONTROLS:
THERMOSTATS
AND ZONING
A08153
ACCESSORIES
ELECTRONIC AIR CLEANER
(EAC)
AIR PURIFIER
MECHANICAL AIR CLEANER
HUMIDIFIER
HEAT RECOVERY
VENTILATOR
ENERGY RECOVERY
VENTILATOR
UV LIGHTS
THERMOSTAT --NON---PROGRAMMABLE
THERMOSTAT --PROGRAMMABLE
ZONING CONTROL
Model EACB
Models GAPAAXBB1625, GAPAAXBB2025
Models EZXCAB, FILCAB
Model HUM
Model HRV
Model ERV
Model UVL
For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover --- T6---NAC, T2---NAC
For use with 1---speed Heat Pump --- deg. F/C, Auto Changeover --- T6---NHP, T2---NHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover --- T6---NRH*
For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and
Humidity Control --- T6---PRH{
For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable --T6---PAC
For use with 1---speed Heat Pump --- deg. F/C, Auto Changeover, 7---Day Programmable --T6---PHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable --T6---PRH*
For use with 1---speed Air Conditioner --- deg. F/C, 5---2 Day Programmable --- T6---PAC
For use with multi---stage applications --- deg. F/C, Auto Changeover, 7---Day Programmable --T2---PHP}
For multi---use / stage configurations --- deg. F/C, Auto Changeover, 7---Day Programmable/
Temperature and Humidity Control ---T6---PRH{
Zone Perfect 3---Zone kit --- ZONEBB3ZAC01, ZONEBB3ZHP01
2---Zone Perfect Plus kit/Temperature and Humidity Control --- ZONEBB2KIT01---B
4---Zone Perfect Plus kit/Temperature and Humidity Control --- ZONEBB4KIT01---B
8---Zone Perfect Plus kit/Temperature and Humidity Control --- ZONEBB8KIT01---B
*Model HP and 2S thermostat must be field converted to air conditioner operation.
{Thermidistatt Control can be configured for multiple use and staging. It must be configured for each specific application.
}Dual Fuel thermostat is used with furnace and heat pump application.
3
BRYANT ACCESSORIES
313AAV/JAV
DESCRIPTION 313AAV/JAV
PART NO.
024045
048070
048090
060110
060135
FILBBCAR0016
X
X
FILBBCAR0020
X
X
Cartridge Media Filter
FILBBCAR0024
X
EXPXXUNV0016
X
X
EXPXXUNV0020
X
X
EZ Flex Media Filter with End Caps
EXPXXUNV0024
X
EXPXXFIL0016
X
X
EXPXXFIL0020
X
X
Replacement EZ Flex Filter Media
EXPXXFIL0024
X
KGAFR0401B14
X
External Bottom Return
KGAFR0501B17
X
KGAFR0601B21
X
X
Filter Rack
KGAFR0701B24
X
External Side Return Filter Rack
KGAFR0801SRE
X
X
X
X
X
KGAWF1301UFR {
S
S
KGAWF1401UFR
S
S
KGAWF1501UFR
S
Unframed Filter 3/4--- in. (19 mm)
KGAWF1306UFR {
X
X
KGAWF1406UFR
X
X
KGAWF1506UFR
X
Flue Extension
KGAFE0112UPH
X
X
X
X
X
Combustible Floor Base
KGASB0201ALL
X
X
X
X
X
Downflow Vent Guard
KGAVG0101DFG
X
X
X
X
X
Vent Extension Kit
KGAVE0101DNH
X
X
X
X
X
Chimney Adapter Kit
KGACA02014FC
X
X
X
X
Chimney Adapter Kit
KGACA02015FC
X
Natural --- to --- Propane Conversion Kit*
KGANP4601ALL
X
X
X
X
X
Propane --- to --- Natural Conversion Kit*
KGAPN3901ALL
X
X
X
X
X
Label Kit
KGALB0101KIT
X
X
X
X
X
Air Leakage Kit (Qty 10)
KGBAC0110DGK
X
X
X
X
X
Air Leakage Kit (Qty 10)
KGBAC0110DGK
X
X
X
X
X
KGAHA0150N42
KGAHA0250N43
(factory supplied)
KGAHA0350N44
KGAHA0450N45
KGAHA0550N46
KGAHA1550N47
Gas Orifice Kit (Qty 50)
See Installation Instructions for model, altitude, and heat value usages.
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55
KGAHA0850P56
KGAHA5750125
KGAHA5750130
*Factory ---authorized and field---installed. Gas conversion kits are CSA (AGA/CGA) recognized.
{Suitable for Side Return Filter Rack (KGAFR0801SRE)
X --- Accessory
S --- Standard
4
PHYSICAL DATA
INPUT BTUH
AFUE%
SHIPPING WEIGHT LB. (KG)
024045
048070
048090
060110
060135
313JAV Upflow; all 313AAV
36,000
53,000
72,000
90,000
107,000
313JAV Downflow/Horizontal
34,000
51,000
69,000
86,000
102,000
313JAV Upflow; all 313AAV
313JAV Downflow/Horizontal
Non--- weatherized ICS
44,000
42,000
80.0
104 (47)
30--- 60
(17--- 33)
0.10
0.50
735
1035
66,000
63,000
80.0
126 (57)
25--- 55
(14--- 31)
0.12
0.50
1230
1460
CERTIFIED TEMP RISE RANGE ˚_F (_C)
CERTIFIED EXT STATIC
PRESSURE (IN. WC)
AIRFLOW CFM
Heating
Cooling
Heating
Cooling
LIMIT CONTROL
HEATING BLOWER CONTROL
BURNERS (Monoport)
GAS CONNECTION SIZE
GAS VALVE(Redundant) Manufacturer
Minimum Inlet Pressure (in. wc)
Maximum Inlet Pressure (in. wc)
IGNITION DEVICE
2
88,000
110,000
84,000
105,000
80.0
80.0
140 (64)
152 (69)
35--- 65
30--- 60
(19--- 36)
(17--- 33)
0.15
0.20
0.50
0.50
1345
1890
1665
2040
SPST
Solid --- State Time Operation
3
4
5
1/2--- in. NPT
White--- Rodgers
4.5 (Natural Gas)
13.6 (Natural Gas)
Hot Surface
132,000
126,000
80.0
163 (74)
40--- 70
(22--- 39)
0.20
0.50
1865
2070
6
*Gas input ratings are certified for elevations to 2000 ft. (610 M)*. In USA, For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305
M) above sea level. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft. (610 --- 1372 M) above sea level. Refer to National Fuel Gas Code
NFPA 54/ANSI Z223.1 ---2006 Table F.1 (d) or furnace Installation Instructions.
{Capacity in accordance with U.S. Government DOE test procedures.
}Airflow shown is for bottom only return ---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each
return ---air supply. An airflow reduction of up to 7 percent may occur when using a Bryant 4 ---5/16 in. (110 mm) high efficiency media filter.
ICS --- Isolated Combustion System
BLOWER PERFORMANCE DATA
UNIT SIZE
DIRECT ---DRIVE MOTOR Hp (ECM --- 5 Speed)
MOTOR FULL LOAD AMPS
RPM (Nominal) --- SPEEDS
BLOWER WHEEL DIAMETER x WIDTHS --- IN (MM)
024045
1/2
6.8
1050--- 5
10 x 6
(254 x 152)
5
048070
3/4
8.4
1050--- 5
11 x 8
(279 x 203)
048090
3/4
8.4
1050--- 5
10X10
(254 x 254)
060110
1
10.9
1050--- 5
11 x 11
(279 x 279)
060135
1
10.9
1050--- 5
11 x 11
(279 x 279)
313AAV/JAV
UNIT SIZE
OUTPUT CAPACITY
BTUH
(Non---weatherized ICS)
313AAV/JAV
SEE NOTES: 1,2,4,7,8,9
UPFLOW
SEE NOTES: 1,2,3,4,7,8,9
UPFLOW
SEE NOTES: 1,2,4,5,7,8,9
DOWNFLOW
A02059
A02061
A02058
SEE NOTES:1,2,3,4,5,7,8,9
DOWNFLOW
SEE NOTES: 1,2,3,4,7,8,9
DOWNFLOW
SEE NOTES: 1,2,4,5,6,7,8,9
DOWNFLOW
A02060
A02063
A02062
Venting Notes
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC),
NFPA54/ANSI Z223.1. In Canada, latest edition of the National Standards of Canada, Natural Gas and Propane Installation Code
(NSCNGPIC), CSA B149.1.
2. Immediately increase to 5--in. (127 mm) vent connector outside furnace casing when 5--in. (127 mm) vent connector required, refer to
Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when
KGAVG0101DFG is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4--in. (102 mm) single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit, KGAVG0101DFG required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and
KGACA02015FC for sizing and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion--resistant sheet metal screws, space approximately 180_ apart.
9. Secure all other single wall vent connector joints with (3) corrosion--resistant screws spaced approximately 120_ apart. Secure Type B
vent connectors per vent connector manufacturer’s recommendations.
6
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
A02068
A02070
313AAV/JAV
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL RIGHT
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL LEFT
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
A02069
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
A02064
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
A02066
7
A02065
A02067
AIR DELIVERY - CFM (WITH FILTER)*
313AAV/JAV
UNIT SIZE
RETURN---AIR
SUPPLY
024045
Bottom or
Side(s)
048070
Bottom or
Side(s)
048090
Bottom or
Side(s)
060110
Bottom or
Side(s)
060135
Bottom or
Side(s)
SPEED
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
0.1
1185
920
735
820
650
1625
1405
1240
1190
1035
1845
1590
1365
1225
1100
2255
1600
1945
1420
1280
2295
1725
1910
1630
1430
0.2
1145
880
685
765
595
1585
1360
1200
1140
985
1800
1545
1320
1160
1030
2205
1525
1890
1340
1205
2240
1660
1865
1575
1355
0.3
1115
835
625
725
535
1535
1320
1155
1095
930
1755
1500
1270
1110
960
2150
1465
1830
1280
1140
2185
1605
1800
1510
1285
EXTERNAL STATIC PRESSURE (in. wc)
0.4
0.5
0.6
0.7
0.8
1075
1035
980
905
820
800
755
720
680
645
585
530
490
435
395
670
630
580
545
490
490
430
390
330
280
1495
1460
1415
1365
1295
1280
1240
1195
1155
1115
1110
1065
1020
975
935
1050
1000
955
915
870
885
835
785
745
695
1710
1665
1595
1500
1400
1455
1410
1365
1315
1270
1215
1170
1125
1070
1025
1060
1010
950
895
830
875
805
730
645
570
2100
2040
1985
1920
1835
1400
1335
1275
1210
1150
1770
1715
1655
1600
1545
1200
1140
1065
1005
925
1055
990
910
840
760
2125
2070
2005
1925
1805
1545
1460
1395
1340
1285
1745
1685
1610
1545
1485
1435
1365
1300
1245
1185
1200
1125
1075
1015
945
0.9
720
605
345
455
235
1220
1070
895
830
650
1275
1180
955
770
505
1735
1080
1480
865
695
1670
1230
1435
1130
855
1
580
540
295
405
--- --1125
1030
850
790
600
1105
1000
900
710
425
1615
1015
1430
790
630
1545
1170
1380
1065
800
*A filter is required for each return ---air inlet. Airflow performance included 3/4 ---in. (19 mm) washable filter media such as contained in factory ---authorized accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. wc available external static pressure.
--- --- Indicates unstable operating conditions.
ELECTRICAL DATA
313AAV/
JAV UNIT
SIZE
024045
048070
048090
060110
060135
VOLTS--HERTZ--PHASE
115--- 60--- 1
115--- 60--- 1
115--- 60--- 1
115--- 60--- 1
115--- 60--- 1
OPERATING VOLTAGE
RANGE*
Maximum
Minimum
127
104
127
104
127
104
127
104
127
104
MAXIMUM
UNIT AMPS
MAXIMUM WIRE
LENGTH FT (M)}
8.1
9.5
10.3
13.1
13.1
34 (10)
29 (9)
27 (8)
34 (10)
34 (10)
MAXIMUM FUSE
OR CKT BKR
AMPS{
15
15
15
20
20
* Permissible limits of the voltage range at which the unit operates satisfactorily.
{ Time ---delay type is recommended.
}Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
8
MINIMUM
WIRE GAGE
14
14
14
12
12
DIMENSIONS
(664mm)
26-1/8"
(FLUE COLLAR)
(733mm)
28-7/8"
(641mm)
25-1/4"
5-15/16"
(135mm)
(22mm)
7/8" DIA
ACCESSORY
22-9/16"
(573mm)
A
JUNCTION BOX
LOCATION
D
F
13/16"
(21mm)
4-13/16"
(122mm)
2-7/16"
(62mm)
1-5/16"
(33mm)
1-1/8"
(29mm)
8-9/16"
(217mm)
1/2" (13 mm) DIA.
THERMOSTAT WIRE ENTRY
AIRFLOW
19"
(483mm)
OUTLET
1/2" DIA. K.O.THERMOSTAT
WIRE ENTRY (13mm)
1-3/4" DIA.RIGHT HAND
GAS ENTRY (44mm)
13/16"
(21mm)
9-5/8"
11/16" 7-3/4"
(17mm) (197mm)(244mm)
11-1/2"
(292mm)
3-15/16" (84mm)
LEFT HAND GAS
ENTRY
33-5/16"
(846mm)
ALTERNAT E
JUNCTION BOX
LOCATIONS (TYP)
24-7/8"
(632mm)
7/8" DIA. K.O. WIRE ENTRY
(22mm)
VENT OUTLET
5 PLACES (TYP)
7/8" (22mm) DIA.
ACCESSORY
7/8" DIA. ACCESSORY
(22mm)
14-7/8"
(378mm)
11/16"
(17mm)
(549mm)
21-5/8"
BOTTOM INLET
1-11/16"
(43mm)
5-1/2"
(140mm)
E
11/16"
(17mm)
3-3/4"
(95mm)
24"
CASING
(610mm)
1-1/2" (38mm)
(560mm)
22-1/16"
SIDE INLET
313AAV/JAV
5-1/2" (140mm)
1-1/4"
(32mm)
1"
(25mm)
A04037
1. Two additional 7/8--in. (22 mm) dia. knockouts are located in the top plate.
2. Minimum return--air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
3. Minimum return--air opening at furnace.
a. For 800 CFM--16--in. (406 mm) round or 14--1/2 x 12--in. (368 x 305 mm) rectangle.
b. For 1200 CFM--20--in. (508 mm) round or 14--1/2 x 19--1/3 in. (368 x 491 mm)rectangle.
c. For 1600 CFM--22--in. (559 mm) round or 14--1/2 x 22--1/16--in. (368 x 560 mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom of single side inlets. The use of both side inlets, a combination of one side and the bottom, or the bottom only
will ensure adequate return air openings for airflow requirements above 1800 CFM.
313AAV/JAV
UNIT SIZE
A
CABINET
WIDTH
IN (MM)
D
SUPPLY WIDTH
IN (MM)
E
BOTTOM
RETURN WIDTH
IN (MM)
F
TOP VENT
OUTLET
IN (MM)
VENT
CONNECTION
SIZE
(see Notes 1 & 2)
MEDIA CABINET
SIZE
IN (MM)
024045
048070
048090
060110
060135
14--- 3/16 (360)
17--- 1/2 (445)
21 (533)
21 (533)
24--- 1/2 (622)
12--- 9/16 (319)
15--- 7/8 (403)
19--- 3/8 (492)
19--- 3/8 (492)
22--- 7/8 (581)
12--- 11/16 (322)
16--- 1/8 (410)
19--- 1/2 (495)
19--- 1/2 (495)
23 (584)
9--- 5/16 (237)
11--- 9/16 (294)
13--- 5/16 (338)
13--- 5/16 (338)
15--- 1/16 (383)
4
4
4
4
4 (Note 1)
16 (406)
16 (406)
20 (508)
20 (508)
24 (610)
1. 135 size furnaces require 5 ---in. (127 mm) vents. Use a 4 ---5 in. (102 ---127 mm) vent adaptor between furnace and vent stack.
2. See installation instructions for complete installation requirements.
9
313AAV/JAV
A08471
ISO 9001:2000
C or p or a
i er
ti
D
SO
M
¨
Before purchasing this appliance, read important
energy cost and efficiency information available
from your retailer.
900
IR
Ca
CERTIFIED
I
TIFIE ®
MEETS DOE RESIDENTIAL CONSERVATION
SERVICES PROGRAM STANDARDS.
SREGISTERED
TER E D F 3
8
I
C
ER
R EG
EFFICIENCY
RATING
CERTIFIED
rr
on
I
DE S GN
1 #A28
REGISTERED QUALITY SYSTEM
25 5/8" (651mm)
5/
8
23 "
(600mm)
24 1/2" (651mm)
With Flanges Bent Out
23 1/8" (587mm)
Opening
3/8
23 "
(600mm)
C Opening
with Flanges Bent In
A
B
Furnace Side
23 3/4"
Centerline Screw Slots
(603mm)
Duct Side
5 3/4"
(146mm)
Media/
Filter Cabinet
A
17"/
B
161/4"/
C
15"/
16"/ (406mm)
(432mm)
(413mm)
20"/ (508mm)
21"/
201/4"/
19"/
(533mm)
(514mm)
(483mm)
25"/
241/4"/
24"/ (610mm)
(635mm)
(616mm)
(381mm)
23"/
(584mm)
A00444
10
TYPICAL WIRING SCHEMATIC
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
NOTE 2
FIVE WIRE
THREE-WIRE
HEATING-ONLY
W
C
R
G
Y
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
DISCONNECT
208/230- OR
460-V
THREE
PHASE
BLOWER DOOR SWITCH
W
BLK
WHT
WHT
GND
115-V FIELDSUPPLIED
DISCONNECT
GND
AUXILIARY
J-BOX
C
O
N
T
R
O
L
R
208/230-V
SINGLE
PHASE
G
COM
GND
NOTE 1
CONDENSING
UNIT
Y/Y2
24-V
TERMINAL
BLOCK
FURNACE
TWO
WIRE
NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation.
2. Some thermostats require a "C" terminal connection as shown.
3. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
A99440
TYPICAL INSTALLATION
CONDENSING
UNIT
HUMIDIFIER
GAS-FIRED
WATER HEATER
ELECTRONIC
AIR CLEANER
AIRFLOW
A08177
11
313AAV/JAV
BLK
GUIDE SPECIFICATIONS
Casing
Casing shall be of .030 in. (.76 mm) thickness minimum,
pre--painted galvanized steel.
Gas Furnace
313AAV/JAV
Inducer Motor
GENERAL
Inducer motor shall be soft mounted to reduce vibration
transmission.
System Description
Draft Safeguard Switch
Furnish a _________________ fixed capacity gas--fired furnace
for use with natural gas or propane (factory authorized conversion
kit required for propane); furnish cold air return plenum; furnish
external medial cabinet for use with accessory media filter or
standard filter.
Draft Safeguard Switch (blocked vent safeguard) shall be factory
installed to reduce the possibility of vent gas infiltration due to a
blocked or restricted vent pipe.
Heat Exchangers
313AAV/JAV
Quality Assurance
Heat exchangers shall be a 4--Pass 20 gage aluminized steel of
fold--and--crimp sectional design when applied operating under
negative pressure.
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be 3rd party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will carry the CSA Blue Star® and Blue Flame® labels.
Unit efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest GAMA Consumer’s Directory of Certified Efficiency
Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Controls
Control shall include a micro--processor based integrated electronic
control board with at least 11 service troubleshooting codes
displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace
within one minute, and a replaceable automotive--type circuit
protection fuse. Multiple operational settings available including,
separate blower speeds for heating, cooling and continuous fan.
Continuous fan speed may be adjusted from the thermostat.
Features will also include temporary reduced airflow in the cooling
mode for improved dehumidification when a Thermidistatt
Control is selected as the thermostat.
Delivery, Storage and Handling
Unit shall be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Operating Characteristics
Heating Capacity shall be ________ Btuh input; ________ Btuh
output capacity.
Fuel Gas Efficiency shall be 80% AFUE.
Air delivery shall be ___________ CFM minimum at 0.50 in. wc
external static pressure.
Dimensions shall be: depth __________ in.; width _________ in;
height_________in. (mm) (casing only). Height shall
be_________in. (mm) with A/C coil and _____________in. (mm)
overall with plenum.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
PRODUCTS
Equipment
Components shall include: slow--opening gas valve to reduce
ignition noise, regulate gas flow, with electric switch gas shut--off;
flame proving sensor, hot surface igniter, pressure switch assembly;
flame rollout switch, blower and inducer assembly, 40va
transformer; low--voltage (heating) (heating/ cooling) thermostat.
Electrical Requirements
Blower Wheel and Blower Motor
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be_________AWG; maximum fuse size
or circuit breaker shall be __________Amps.
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed bearings, of _______hp, and
shall be multiple--speed direct drive. Blower motor shall be soft
mounted to the blower scroll to reduce vibration transmission.
Special Features
Refer to section of the product data sheet identifying accessories
and descriptions for specific features and available enhancements.
Filters
Furnace may have reusable--type filters. Filter shall be _______ in
(x) _______in. (mm).An accessory high efficiency Media Filter is
available as an option. _______________ Media Filter.
8 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 3/09
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.