Bryant P474-0401RF Coffeemaker User Manual

PROGRAMMING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
41170.0000B 05/12 ©2010 Bunn-O-Matic Corporation
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers
and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor.
2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below:
a) Electronic circuit and/or control boards - parts and labor for 3 years.
b) Compressors on refrigeration equipment - 5 years parts and 1 year labor.
c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts
and labor for 4 years or 40,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be
commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the
applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured
by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation,
improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality,
damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but
not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN
prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office
Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an
authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under
warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make
modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such
individuals, whether oral or written, do not constitute warranties and should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the
applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair
is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for
the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS
EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION
AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of
use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities
or services, or any other special, incidental or consequential damages.
392, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN
Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic,
Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design,
Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with
the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel,
Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh,
Titan, trifecta, Velocity Brew, A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profit
Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brewer
Control, Nothing Brews Like a BUNN, Pouring Profits, Signature Series, Tea At Its Best, The Horizontal Red Line, Ultra are
either trademarks or registered trademarks of Bunn-O-Matic Corporation.
Page 2
41170 030912
CONTENTS
LOCKOUT SWITCH .............................................................................................4
PROGRAMMING SWITCHES...............................................................................5
PROGRAMMING .................................................................................................6
Page 3
411701 061308
ADJUSTMENTS & PROGRAMMING
PROGRAMMING THE BREWER
The programming of the brewer is divided into two levels. Brewing adjustments are in Level 1. Service functions are accessed in Level 2.
The following function screens are in order of appearance. Each screen will have instructions on how to
access, and the procedures to program the various functions of the brewer.
IMPORTANT PROGRAMMING NOTES
- READ CAREFULLY To exit the programming mode at any time, press and hold "Hidden" switch located on the front panel. The
display will return to the MAIN SCREEN.
If none of the programming switches are pressed within one minute during programming, the display will
return to the MAIN SCREEN.
Always remember to place an empty cup under the sprayhead when operating the brewer during the set-up
of PULSE BREW, CALIBRATE FLOW and testing the brew valve in SERVICE TOOLS/TEST OUTPUTS.
PROGRAMMING LOCKOUT SWITCH
(Mounted on main control board)
This switch can be set to prevent access to
the programming settings of the brewer.
Once all the correct brew settings are programmed, the operator can set the switch
to the "ON" position to prohibit anyone from
changing the settings. With the switch in the
"ON" position, the programming menus can
still be accessed to view the current settings.
However, no changes will be saved.
Disconnect brewer from power source
before removing any panel!
Page 4
411701 061308
PROGRAM FUNCTIONS
MAIN SCREEN
R
WE
RE
B
OD
toP
Au
HIDDEN SWITCH
Press until display reads
"BREW LOCKOUT"
Press/hold to exit program
LL BR
BRE
E
SMALL
BREW
Step backwards through screens
BREW LOCKOUT:
NEXT
BREW LOCKOUT ?
NO
DONE
YES
Prevents brewing if the water temperature is less than
the "SET READY" temperature. To access this function
screen press and hold the hidden switch. Release when
the display reads: "BREW LOCKOUT".
The YES or NO should be flashing. Select YES to prevent
brewing if the water temperature is below the set READY
temperature. Select NO to permit brewing at any water
temperature.
When finished, press and release DONE. This will step to
the next function screen. To return to the MAIN SCREEN
at any time, press and hold the hidden switch.
Press here
for NO
B
Press here
for YES
A
Press here
for DONE
Page 5
411701 061308
PROGRAM FUNCTIONS
BREW TYPE A
TEA
DONE COFFEE
BREW OZ A:
(-)
BREW OZ. (A/B) (1-16)
Adjust brew volume.
8.0
DONE
(+)
BREW METER A: 2
-
+
ENTER SERVICE #?
NO
YES
ENTER PASSWORD
0
0
0
SET PASSWORD
0
0
0
SET LANGUAGE ?
NO
YES
UNITS
METRIC DONE ENG
SET TEMP:
(-)
200°
DONE
(+)
SET READY:
195°
(-)
DONE
DONE
DONE
ENTER PASSWORD
User must enter a 3 digit number to access remainder of adjustments. If no
number has been pre-programmed (0 0 0), then access is allowed.
SET PASSWORD (001-999)
Program any three digit number as a password.
SET LANGUAGE
Choose between English or Spanish.
UNITS
Choose between English (Oz, F°) or metric (Ml, C°)
SET TEMP
Adjust tank temperature 185 to 205° F (85 to 96° C)
YES
ENTER ASSET #
This function allows the you to enter in an optional 4 digit number. This can be
useful for tracking the usage of an individual machine within a group.
YES
AIR TIME A/B: 15.0
(-)
ENTER SERVICE #
Program service phone number to be displayed anytime there is a fault message.
(+)
SetPulseBrew A/B ?
NO
BREW METER (A/B) (1-5)
Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.
SET READY
Sets the minimum temperature allowable to start a brew cycle, if "BrewLockout"
is enabled. Range: (2° to 20° F) or (2° to 10° C) below the set temperature.
ENTER ASSET # ?
NO
BREW TYPE (A/B) (Tea/Coffee)
Tea setting provides half the "purge" pressure as coffee at the end of brew
cycle.
(+)
SET PULSE BREW (A/B)
Individually adjust on/off times. 1st on time: OFF-.5-24.0; OFF time: OFF-.5-24.0;
Last on time: Preinfusion-.5-24.0 This will overwrite "BREW METER"
AIR TIME (A/B) (1-25 seconds)
Time the brew tank is purged at the end of each brew cycle.
CONTINUED
Page 6
411701 061308
PROGRAM FUNCTIONS
DRIP T I M E A/B: 15
(-)
DONE
(+)
BREWS TO EMPTY
(-)
25
(+)
Enabl EnergySavr
NO
DONE
YES
AIR PUMP POWER 4
(-)
DONE
(+)
BREW COUNT ##
NO
YES
BREW COUNT ##
RESET
NO
YES
PRESS
BREW TO START
ENTER OZ
DONE
10.0
(+)
SERVICE TOOLS ?
NO
YES
TEST OUTPUTS ?
NO
YES
INDEX
B
DUMP
NEXT
TOR
MOTOR
LOAD
AL R
EXTERNAL
RELAY
ON
BREWS TO EMPTY (OFF/15-25)
Set number of used pods in bin to turn on "EMPTY BIN" message.
ENABLE ENERGY SAVER
Choose to have the tank heaters turn off, or reduce the tank temp to (140° F)
or (60° C) once the "SET IDLE TIME" has expired. .5-50.0 hrs.
AIR PUMP POWER (1 Weakest - 4 Strongest )
Adjust air pressure for end of brew cycle purge. Due to pod variations, reduce
as needed if splattering occurs.
BREW COUNTS
Retains the total number of brew cycles completed, not reset-able.
BREW COUNTS
Retains the total number of brew cycles completed, reset-able.
NEXT
CALIBRATE FLOW ?
(-)
DRIP TIME (A/B) (OFF/1-50 seconds)
Time between brew cycle and pod ejection.
NEXT
OFF
CALIBRATE FLOW
This function allows you to enter the actual flow rate of the sprayhead by dispensing for one minute. The volume is then entered in ounces per minute. (Oz/M)
Place a 10 ounce or larger measuring cup under sprayhead and press one of
the brew switches.
After dispense finishes, read number of ounces and enter that amount into brewer
using the +/- switches, then press "DONE" to set the volume into memory.
SERVICE TOOLS allows testing of load components and switches.
It should only be used by trained technicians.
TEST OUTPUTS allows testing of load components by manually turning them
ON/OFF.
---PLACE A 10 OUNCE CUP UNDER DISPENSE AREA--WARNING: HOT WATER WILL DISPENSE DURING SOME TEST MODES!
INDEX MOTOR DUMP runs the pod holder back to the pod ejection position.
LOAD moves it out to the door open position. "B " indicates the assembly is
in home postion.
EXTERNAL RELAY Main control board outputs 12vdc to activate external relay.
The N.O. contact then closes to provide line voltage to the heater in HOT WATER
TANK.
CONTINUED
Page 7
411701 061308
WaterInIet
ON
#
NEXT
OFF
AIR PUMP
ON
NEXT
OFF
HOT WATER
ON
NEXT
OFF
VENT VALVE
ON
NEXT
OFF
WATER PUMP
ON
NEXT
OFF
HotWaterAir PUMP
ON
NEXT
OFF
TANK HEATER
ON
NEXT
OFF
TEST SWITCHES
?
WITC
NO
WATER INLET
Activates the water inlet valve for the brew tank, and flow meter count.
AIR PUMP
Activates the air pump motor for the brew tank.
HOT WATER
Activates the water inlet solenoid for the hot water tank.
VENT VALVE
Activates the vent solenoid for the hot water tank.
WATER PUMP
N/A
HOT WATER AIR PUMP
Activates the air pump motor for the hot water tank.
TANK HEATER
Activates the triac/relay on the main control board for the brew tank heater.
TEST SWITCHES allows testing of the membrane switches.
YES
PROGRAM
M SW
SWITCH
CH
TO EXIT
FACTORY BLOWOUT
FACT
NO
YES
AutoPOD
BREWER
Auto
VERSION
FACTORY BLOWOUT
Used for tank draining.
YES
FACTORY DEFAULTS
FACT
NO
Press the hidden program switch to go back to previous screen. Pressing any
other membrane switch will give corresponding readout for that switch.
xx.xx
FACTORY DEFAULTS
Reset all brew settings, calibrations back to factory presets.
Requires following "INITIAL SETUP" procedure.
EXIT PROGRAM MODE TO MAIN SCREEN