Pentair IntelliChem Water Chemistry Controller Installation and User’s Guide
Reklama
Reklama
IntelliChem
™
Water Chemistry Controller for Swimming Pools
pH OK 7.46
Mixing 00:07:03
ORP OK 450
Mixing 00:07:54
Menu Select
Alarm
Installation and User’s Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
IntelliChem™ Installation and User’s Guide
Technical Support
Phone: (800) 831-7133 - Fax: (800) 284-4151 visit www.pentairpool.com and www.staritepool.com
:
CONTENTS
IMPORTANT WARNING AND SAFETY INSTRUCTIONS ....................................... i
IntelliChem Overview ............................................................................................... 1
Operator Controls Indicators and Alarm LEDs ......................................................... 2 pH Settings and ORP Settings Buttons .................................................................... 3
Auto Setup ................................................................................................................ 6
IntelliChem Menus ................................................................................................... 9 pH Menu ................................................................................................................... 11
ORP Menu ................................................................................................................ 14
Configuration Menu .................................................................................................. 17
Saturation Index ....................................................................................................... 24
Installation ................................................................................................................ 28
Setting up IntelliTouch Automation Control System ................................................. 43
Setting up EasyTouch Automation Control System ................................................. 45
Setting up SunTouch Automation Control System ................................................... 46
Troubleshooting ........................................................................................................ 46
Maintenance ............................................................................................................. 51
Replaceable Parts List ............................................................................................. 54
© 2011 Pentair Water Pool and Spa, Inc. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
IntelliChem™, IntelliFlo
®
, IntelliTouch
®
, EasyTouch
®
, SunTouch
®
, IntelliChlor
®
MobileTouch
® and Pentair Water Pool and Spa ® are trademarks and/or registered trademarks of Pentair
Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Teflon ® is a registered trademark of E.I. Du Pont De Nemoursand Company
Corporation. Unless noted, names and brands of others that may be used in this document are notused to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair WaterPool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.
P/N 521363 Rev
B - 08/17/11
IntelliChem™ Installation and User’s Guide
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS
PRODUCT IS NOT INSTALLED AND USED CORRECTLY.
INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST
READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE
USING THIS PRODUCT.
Most states and local codes regulate the construction, installation, and operation of public pools and spas, and the construction of residential pools and spas. It is important to comply with these codes, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information.
IMPORTANT NOTICE
- Attention Installer: This Installation and User’s
Guide (“Guide”) contains important information about the installation, operation and safe use of this product. This Guide should be given to the owner and/or operator of this product.
Before installing this product, read and follow all warning notices and instructions in this Guide. Failure to follow warnings and instructions can result in severe injury, death, or property damage.
Call (800) 831-7133 for additional free copies of these instructions. Please refer to www.pentairpool.com for more information related to this products.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION:
BEFORE WORKING ON INTELLICHEM: Always disconnect power to the IntelliChem controller at the circuit breaker before servicing.
Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock.
BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS BEFORE
SERVICING INTELLICHEM. AC Power may be supplied to the relay terminals Ex_Relay1 and Ex_Relay2 from other sources. See page 31 for details.
This product must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the National Electrical Code (NEC), NFPA 70 or the
Canadian Electrical Code (CEC), CSA C22.2. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property.
BEFORE USING YOUR POOL, SPA OR HOT TUB, CHECK THE pH AND SANITIZER LEVELS OF THE WATER.
Do not permit children to operate this equipment.
When mixing acid with water, ALWAYS ADD ACID TO WATER.
NEVER ADD WATER TO ACID.When adding any chemical to the pool/ spa, be sure to follow the manufacturer’s instructions thoroughly.
DO NOT MIX SODIUM HYPOCHLORITE AND MURATIC ACID
Risk of electrical shock. Connect IntelliChem to a ground-fault interrupter-circuit (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI.
IntelliChem™ Installation and User’s Guide i
ii
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling into any pipes. Securely fasten all electrical, water and chemical lines.
Locate chemical feed pumps and chemical storage tanks in a safe and secure area.
Strictly follow the acid manufacturers safety and handling protocols including hand, body and eye protection when transferring or handling acid. Safety precautions should be used when handling Muriatic acid to control pH water levels. Muriatic acid can cause serious body injury and damage pool equipment. Extra care must be taken when installing, maintaining and operating acid pump feed systems. Acid is dangerous to handle and should be properly contained, transported, poured, stored, and dispensed.
• Check the pH and sanitizer levels of the water before use.
• Periodically use an independent pH and Chlorine test kit to verify that pH and chlorine is at a safe level. If the pH and Oxidation Reduction Potential
(ORP) or Flow Cell sensors are broken, depleted or dirty with oils, lotions, or other contaminants, they can report inaccurate results to the system causing incorrect water chemistry, which could harm people or equipment.
• Check the IntelliChem main status display each day to ensure there are no Alarm messages. See “Troubleshooting” on page 46 for more information.
When using IntelliChem with a pool pump timer: The Association of Pool and Spa
Professionals (APSP) recommends that all water in a residential pool pass through the filtration system at least once every 12 hours (referred to as pool water turnover).
However, many factors have an effect on actual pump and filter system run times. Pool size, source of water, direct sun light, indoor/outdoor, screened and unscreened, filtration system, cold or hot weather, swimmer load, rain, organic debris, algae, etc., are all factors which contribute to either more or less pool pump and filter system run times. Because of these differences, it is extremely difficult to set an initial run time (starting point) for the pool pump and chlorinating system. Try initially setting the pool pump timer to 12 hours. It will take a few days to get just the right amount pool pump operating time. When the
Chlorinator is wired with a pool pump timer (see page 6) results will vary greatly from one pool installation to the next, so this should be discussed with either the pool builder or your pool professional.
Using CO2 for pH Control
Plaster pools and pools using salt-chlorine generators typically cause a slow pH rise which must be managed. With IntelliChem, muriatic acid or carbon dioxide (CO2) is dispensed into the filter system’s return water as needed until the Flow Cell pH sensor detects the proper pH level. Using CO2 for pH control eliminates the need to handle and stored acid and can be a safer method. As CO2 gas is injected into the pool water, it dissolves and creates carbonic acid. This weak acid is very efficient at lowering pH with the added benefit of self-limiting if the CO2 is over-fed.
IntelliChem™ Installation and User’s Guide
1
Overview
IntelliChem is a pH and ORP sensing device that dispenses correct amount of chlorine or bromine, muriatic acid or CO2 gas. IntelliChem provides continual analysis of your swimming pool water sanitation and pH levels, providing real-time status information to dispense the proper amount of muriatic acid (pH reducer) and chlorine or bromine for the correct sanitization and pH balance. IntelliChem operates with or without a salt chlorine generator to provide a self-replenishing supply of chlorine generated from salt.
IntelliChem can also connect to carbon dioxide (CO2) liquid gas tanks to lower pH in your swimming pool water. When CO2 dissolves into water it produces weak neutral bicarbonate salts which reduces pH. CO2 is environmentally friendly and produces no secondary pollution into the treated water by salts such as chlorides or sulfates. CO2 does not corrode metal equipment and does not require any special piping. IntelliChem supports Pentair Water Pool and Spa® (“Pentair”), EasyTouch®, IntelliTouch® and
SunTouch® automation control systems for pH and ORP control. IntelliChem also supports IntelliChlor® salt chlorine generator (SCG) to help manage your pool water sanitizer levels.
Operating IntelliChem
Before operating IntelliChem, it’s important to test and adjust your pool water chemistry to the recommended pool industry levels found in this manual (see page 19). If you are using an IntelliChlor salt chlorine generator, adjust the salt levels to the recommended levels in the IntelliChlor Installation and User’s Guide (P/N 520589). During normal
IntelliChem operation, no user input is required, IntelliChem will automatically sense
ORP and pH levels. The current ORP and pH levels are regularly displayed on the control panel LCD display. Use the pH Settings or ORP Settings buttons to view or adjust supply levels. The IntelliChem “Auto Setup” feature provides screen prompts for first-time setup or standard configurations such as setup reminder times, calculating feed times, proportional limits and alarms. For details, see page 6.
First Balance Your Pool Water
IMPORTANT: To help keep your pool water balanced follow these steps:
1.
Use a Test Kit (with fresh testing reagents) to measure the pH, alkalinity,
and calcium hardness of the pool water. For greater accuracy, Pentair recommends the AcuCheck3 Test Kit to measure pH, chlorine ppm, and alkalinity levels (P/N 745000110). “Balanced” water has proper levels of pH, Total Alkalinity and Calcium Hardness. This “balanced” water is neither corrosive or scaling. The pH (0-14) value is the scale of relative acidity or alkalinity. Recommended pH range is from 7.2 to 7.6. The
IntelliChem default pH value is 7.5 (see page 12).
2.
Be sure the pool chlorine level is balanced. Ideal free chlorine level should be between 1.0 - 3.0 parts per million (ppm).
3.
Use the online Langelier Saturation Index (LSI) calculator to diagnose the water balance in your pool or the IntelliChem built-in LSI calculator
(see page 24-27). Refer to: http://www.pentairpool.com/pool-owner/resources/calculators/langelier/
Note: A Saturation Index value of 0 indicates the water is chemically in balance. If the
Index is a minus (-) value, corrosive tendencies are indicated. If the Index is a plus (+)
value, scale-forming tendencies are indicated. A Saturation Index value between +0.3
to -0.3 is considered satisfactory in a swimming pool. See Saturation Index menu on page 24.
IntelliChem™ Installation and User’s Guide
2
Operator Controls, Indictor and Alarm LEDs
CONTROL PANEL DESCRIPTION
1
2
3
4 pH
SETTINGS
ORP
SETTINGS
FLOW pH OK 7.46
Mixing 00:07:03
ORP OK 450
Mixing 00:07:54
MENU Select
ALARM
9
8
5
6
7
Control Buttons and LEDs:
1
2
3
4
5
6
7
8
9
Liquid Crystal Display (LCD) with backlighting: Displays system status information and IntelliChem main menu. Display backlight and menu on and off time (30 seconds to 24 hours) can be set via the “LCD Timeout” menu feature. See
“Configuration” menu page 17).
Display viewing modes: Select between two display modes: Basic: pH and ORP status with alarms messages. Advanced: pH, ORP, status, alarm messages and process timers.
pH Settings button: Access the pH settings (see page 3).
ORP Settings button: Access the Oxidation Reduction Potential (ORP) settings
(see page 3).
Flow LED: Green LED on indicates flow is detected. LED will blink during flow delay.
LED off indicates no flow in the system. If flow is not present, no chemical feeding or
IntelliChem activity is allowed. LED brightness can be adjusted via the Configuration
“Display Mode” menu (see page 17).
Left arrow button: Scroll through sub-menu items or move cursor left when editing a setting.
Menu button: Access the IntelliChem main menu (see page 11). While in menu mode, used to exit a menu level. All items are saved as soon as they are changed.
Right arrow button: When in menu mode, selects menu main and sub-menu item, scroll through sub-menu items or move cursor right when editing a setting.
Alarm LED: LED is on if an alarm condition occurs. Display shows alarm message and status (see page 48). LED brightness can be adjusted via the Configuration
“Display Mode” menu (see page 17).
Up/Down arrow button: When in a menu mode, use
/ to scroll through main menu and sub-menu items, increase, decrease or change a setting or value. Also, used for moving to next sub-menu page 1/2 - 2/2.
IntelliChem™ Installation and User’s Guide
pH Settings and ORP Settings Buttons
pH Dosage (dispense acid)
DO NOT manually feed pH (acid) and ORP sanitizer (chlorine) at the same time without sufficient water flow through the piping system. Combining these two chemicals without sufficient water flow for mixing will result in the formation of hazardous gas. This menu item will be displayed as
Override [Wait] during no-flow and flow-delay time period.
pH
SETTINGS
pH Settings button: Press the pH Settings
button to access the pH dosage settings.
pH Settings
Override [Dose]
Level Gauge: 5
Limit cleared
3
ORP
SETTINGS
ORP Settings button: Press the ORP Settings button to access the Oxidation Reduction Potential (ORP) settings. The ORP is the sanitization quality of the water of a given solution.
ORP Settings
Override [Dose]
Level Gauge: 5
Limit: [Clear ]
Note: To exit pH Settings and ORP Settings, press the MENU button.
Password Protect: The pH Settings and ORP Settings screens are not accessible when the Password Lock is set to “ALL”. Set the Password Lock to “OFF” or “MENU” to access these screens (see page 5).
Override (pH): Press the
/ Right or Left arrow button to toggle between “Dose” or
“Stop”. Select “Dose” to dispense muriatic acid or CO2 and select “Stop” to stop dispensing acid or CO2 (pH Settings LED is on). To exit, press the MENU button or press the
Down button to select the “Level Gauge” feature. The Override feature is not available when CO2 is setup to “Feed to Setpoint.”
Override (ORP): Press the
/ Right or Left arrow button to toggle between “Dose” or “Stop”. Select “Dose” to dispense chlorine (or bromine) and select “Stop” to stop dispensing chlorine (ORP Settings LED is on). To exit, press the MENU button or press the
Down button to select the “Level Gauge” feature. The Override feature is not available when IntelliChlor is setup to “Feed to Setpoint.”
Level Gauge indicator: Press the
/ Up/Down button to select this feature. The level gauge (volume based) and hour glass (time based) icon is a visual representation of the amount of acid (pH Settings) or chlorine (ORP Settings) available in the container. Press
/ six times to fill the gauge (container full). The indicator displays six horizontal bars when full. The level gauge is not available if the doser is unable to determine the pump dispense rate, the supply volume, or if there is no supply “reminder” set up (see page 13-15). The gauge is displayed as an “hour glass” if the supply is based on time rather then volume (see page 6)
Limit [Clear]: Press the
/ to select this feature. Press the / to clear the current dosage limit timer. After pressing the button, “CLEARED” is displayed, indicating that the current dosage limit is cleared.
IntelliChem™ Installation and User’s Guide
4
IntelliChem System Power Up Screens
IntelliChem
v1.010 01/12/11
Pentair Water
Pool and Spa
Power-up Sequence: During power-up IntelliChem displays the initialization screens before the main status screen is displayed. During this initial power up sequence, IntelliChem performs an internal self test and continues with a system calibration. The first screen includes the current software version and date.
AUTO CALIBRATION
AUTO CALIBRATION is displayed each time IntelliChem is powered up.
AUTO CALIBRATION pH 6.35 7.65 OK
ORP 738 398 OK
***PASSED***
IntelliChem Auto
__Setup Wizard__
Press MENU to go
to each new step
In the next auto-calibration sequence the pH and ORP meters are tested with on-board circuitry and calibrated to the built-in reference devices. An out-of-tolerance condition is immediately reported as an error so the user can have the unit serviced.
The very first time IntelliChem is powered up and after a factory reset, the Auto Setup Wizard start screen is displayed.
Otherwise access the wizard from the main menu
(see page 6).
Awaiting
POWER&FLOW DELAY
H:00 M:14 S:18 please wait...
The normal start up screen will simply be this one, awaiting
Power On & Flow Delay. The countdown timer shows the remaining time before the unit starts reading the probes and controlling the doser.
pH OK 7.5
ORP OK 450
Main Status Screen: After IntelliChem has completed the
Flow Delay the main status screen displays the measurements of the connected pH and ORP sensors.
IntelliChem™ Installation and User’s Guide
Set Password Protect
The password protect feature prevents access to certain menus and prohibits all menu changes and manual feeds. For more information, see Set Password on page 18.
To set the password protect:
Set Password
PW [1234]
Lock [Off ]
Locked - Please enter password
> 1234
1.
Press MENU
/ Configuration and
/ Set Password.
2.
Set Password (PW): Press the
/ Up/Down
arrow button to select the first password digit (0-9).
3.
Press the
/ Right/Left arrow button to move the cursor to the next digit.
4.
Press the
/ Up/Down arrow button to select the second password digit. Repeat steps 3 and 4 for the third and fourth password digit.
5.
Press the
Right arrow button to move the cursor to the Lock Menu setting.
6.
Press the
/ Up/Down arrow button to select
OFF: Do not enable control panel button lockout.
ALL: Lockout MENU, pH Settings and ORP Settings buttons). Tank Levels cannot be changed.
MENU: Lockout MENU button (not pH Settings and
ORP Settings buttons). Setpoints or Sat Index values
TA, CYA, CH cannot be changed.
7.
To exit, press the MENU button (press three times to return to the main screen.
Tip: Setting the password 0000 allows you to enter a protected screen by pressing MENU. Also, once the password is entered, access is granted for the duration specified by the Menu timeout setting in the
Configuration/Display Mode menu (see page 17).
5
Password Protect and IntelliTouch, EasyTouch and SunTouch
Automation Control Systems
Note: If the password lock is enabled from IntelliChem it will also be locked out on the IntelliTouch, EasyTouch or SunTouch automation control system.
When IntelliChem is controlled by the IntelliTouch, EasyTouch or SunTouch automation control system, if the password is set and locked on the IntelliChem, it cannot be
changed from the automation control panel. To change a “LOCKED” password from the automation system, enter the password on the IntelliChem, it will remain active for the
Menu Timeout MM:SS period. During that time, the automation system will be able to set the appropriate settings, just as you would from the IntelliChem front panel. Receiving updated settings from automation will continue to extend the Menu Timeout, just as if you're accessing the menu on the IntelliChem itself.
IntelliChem™ Installation and User’s Guide
6
Display Modes
IntelliChem main status screen can be setup to display basic or advanced system information. To setup the Display Mode, see “Configuration” menu on page 17. The
Basic display mode shows the current pH and ORP measurements including a message describing any existing pH (line two) and ORP (line four) alarms. The Advanced display mode shows all the current measurements and alarm messages as well as dose and mix timers showing the progress of those processes.
Basic display mode pH >OK 7.4
-.72 Scaling
ORP OK 730
Monitoring
The Basic mode displays the current pH and ORP measurements (pH in10th and ORP in 5mV) with any alarms and tank levels if enabled.
Note: Alarms are displayed on all Basic and Advanced modes.
>OK or <OK is displayed as soon as the value exceeds alarm trip point. That is replaced with “HIGH/LOW” after the specific alarm delay time period.
Advanced display mode
Displays three different Alarms. The example screen shows:
pH HIGH 7.91
pH Dose Limit
ORP OK 683
Mixing 00:07:54
Dose limit, high reading and chemical tank low alarm. These can co-exist. The advanced mode displays the current pH and
ORP high precision measurements (extra digit. e.g. pH=100th
- ORP=1mV resolution), alarms, tank levels, process messages and timers.
Basic and Advanced Display with Error Messages
NO FLOW DETECTED
Check pump, flow
Cell, filter,
and valves.
If IntelliChem detects the pool water circulation pump is not active, a NO FLOW message is displayed. ORP and pH values are not measured when there is no flow, and therefore not displayed.
Auto Setup
Use the Auto Setup feature for first-time setup or standard configurations. Follow the onscreen prompts and enter information about your system configuration (pH/ORP internal or external pumps, pool size, filter time, chemical container size etc. IntelliChem uses this information to automatically setup reminder times, calculate feed times, proportional limits and alarms. The following describes the Auto Setup screen. Press the MENU
button to access the Auto Setup menu. To change a menu setting or value press the
Press MENU
Previous Values: Use to recalculate new dose times etc., if no custom settings exist. Not recommended for custom settings; use the menu directly to make these changes.
Reset All: Make major configuration changes that may have conflicts with previous settings.
IntelliChem Auto
__Setup Wizard__
Press MENU to go to each new step
To exit
Auto
Setup, press
Dosing will resume when you
_exit this menu_
Press any button
Would you
like to use
previous values?
[Yes | Reset All]
IntelliChem™ Installation and User’s Guide
Auto Setup
(Continued)
What is your
Hardware Setup?
pH ORP
[L_Pump R_pump]
What size is the body of water?
Volume: 10.0K
Units: gal-US
Press the
scroll through the six configurations.
How long does your filter run?
Daily:H:08 M:00
Press the MENU select next screen
What is the pH
Container Size?
1.00 gal-US
Gauge: 6
Enter ORP info on next screen.
What is your
Hardware Setup?
pH ORP
[L_Pump ICHLOR]
What size is the body of water?
Volume: 10.0K
Units: gal-US
How long does your filter run?
Daily: H:24 M:00
What is the pH
Container Size?
1.0 gal-US
Gauge: 6
7
What is your
Hardware Setup?
pH ORP
[RELAY2 ICHLOR]
What is your
Hardware Setup?
pH ORP
[RELAY2 RELAY1]
Enter doser pump rated output for pH: 1 GPD (1-400)
What size is the body of water?
Volume: 10.0K
Units: gal-US
Select Use Time ("0") if the doser pump's
GPD (gallons-perday) feed rate is unknown.
Enter doser pump rated output for pH: 1 GPD (1-400)
ORP: 1 GPD
What size is the body of water?
Volume: 10.0K
Units: gal-US
How long does your filter run?
Daily: H:08 M:00
What is the pH
Container Size?
1.0 gal-US
Gauge: 6
How long does your filter run?
Daily: H:08 M:00
What is the pH
Container Size?
1.0 gal-US
Gauge: 6
Enter ORP info on next screen.
What is your
Hardware Setup?
pH ORP
[CO2/R2 L_PUMP]
How long should
CO2 dose be
H:00 M:05 S:00
What size is the body of water?
Volume: 10.0K
Units: gal-US
How long does your filter run?
Daily: H:08 M:00 pH Chem
Reminder in:
H:00 M:00
Continue on next page
What is the pH
Container Size?
1.0 gal-US
Gauge: 6
IntelliChem™ Installation and User’s Guide
8
Auto Setup
(Continued)
What is your
Hardware Setup?
pH ORP
[CO2/R2 ICHLOR]
How long should each CO2 dose b e ?
H:00 M:05 S:00
What size is the body of water?
Volume: 10.0K
Units: gal-US
How long does your filter run?
Daily: H:08 M:00 pH Chem
Reminder in:
H:00 M:00
Is your pool water balanced?
[No]
YES
Finished Setup.
Verify your new settings in the pH & ORP menus!
NO
Balance water chemistry before beginning automatic control
IntelliChem System Default Values
pH
pH Set Point: pH Alarm High: pH Alarm Low: pH Alarm Delays:
Sensitivity:
ORP
ORP Set Point:
ORP Alarm High:
ORP Alarm Low:
ORP Alarm Delays:
Sensitivity: pH Lockout:
Miscellaneous Default Values
Display Mode:
Control Panel LED Brightness:
Menu Timer:
Menu Backlight Timer:
Power-On Delay:
Flow Switch Delay:
Dose Priority:
Password 1234 - Lock = Off
7.5
7.8
6.8
5 min. for both
Low (Off for CO2)
700
750
650
5 min. for both
Low (Off for IntelliChlor)
7.8
Basic
10%
M:02 S:30
M:00 M:20
14 minutes
1 minute
Simultaneous dosing
IntelliChem™ Installation and User’s Guide
9
MENUS
MAIN SCREEN
PH MENU
(page 11)
pH Dosage (Page 1/2) Dosage (For liquid; Volume/Time):
(For CO2; Time or to set point): Mixing Time: H:24 M:59
pH Dose by Volume (Page 2/2) Dose: [0-9999], Limit: [0-64350],
Units: [oz/ml], Clear [Manual]
pH Dose by Time (Page 2/2) Dose: [00:00:00], Limit: [00:00:00], Clear: [Power-On]
pH Dose to Setpoint (Page 2/2) Limit: [00:00:00], Clear: [24hr Flow]
pH Setpt: 7.5 (use Left/Right button to adjust pH set point)
pH Tweak - reading = 7.xx tweak: 0.0 (+/- 0.3)
pH Supply (Page 1/2) Units: gal-US/gal-UK/Liters/Time, Chemical: [Acid, pH-, Base, pH+] -
Page 2/2 - Capacity: 0.000-200.00 gal-US/galUK/Liters - Gauge: Egg timer or tank gauge -
Page 2/2 Time: Reminder in: H:100 M:00
Sensitivity: - [Low/High/Off] - Full Dose at 0.5pH (Low - Liquid, CO2),
(High 0.2pH from set point).
pH Alarms: Page1/2 High 7.8 - Delay 00:05:00 - Page 2/2 Low: 6.8 Delay 00:05:00
ORP MENU
(page 14)
SAT INDEX
AUTO SETUP
ORP Dosage (Page 1/2) Dosage (For liquid; Volume/Time):
(For SCG; Time or to set point): Mixing Time: H:24 M:59
ORP Dose by Volume (Page 2/2) Dose: [0-9999], Limit: [0-64350], Units: [oz/ml], Clear [Manual]
ORP Dose by Time (Page 2/2) Dose: [00:00:00], Limit: [00:00:00], Clear: [Power-On]
ORP Dose to Setpoint (Page 2/2) Limit: [00:00:00], Clear: [24hr Flow]
ORP Setpt: 700 (use Left/Right button to adjust ORP set point)
ORP Tweak - reading = xxx tweak: 0.0 (+/- 50mV)
ORP Supply (Page 1/2) Units: gal-US/gal-UK/Liters/Time, Chemical: [Chlorine/Bromine] -
Page 2/2 - Capacity: 0.000-200.00 gal-US/galUK/Liters - Gauge: Egg timer or tank gauge -
Gauge: Egg Timer or tank gauge - Page 2/2 Time: Reminder in: H:100 M:00
Sensitivity: - [Low/High/Off] - Full Dose at 50 mV ORP (Low - Liquid),
(High 20 mV from set point, Off (IntelliChlor OFF)
ORP Alarms: Page1/2 High 750 - Delay 01:00:00 - Page 2/2 Low: 650 Delay 02:00:00
See page 24 for details - pH: 7.5 - Temp: 00°F -
- CH: xxx - TDS: xxx - TA:xx = CYA: xx Recalc/Tab:
See page 6 for details
CONFIGURATION
(page 17)
Pool Details:Volume: 0.2K-230K (200-230,000 Liters max) Units:
Gal US (gal-US/gal-UK/Liters), Daily Hrs/Mins
Display Mode: Display Mode: Basic/Advanced, Brightness Front LEDs: (0-100%),
Menu/BkLt Hrs/Mins. (24 hrs -30sec.)
Delays: Power-on: 1-60 mins. (15min default) - FlowSwitch: 1-60 mins. (1 min default) -
Doser/Probe: Seconds 0,15,30,60secs.
Set Password: PW [1234] - Lock [OFF/MENU/ALL]
Preferences: pH Lockout: 7.8, Preferences 2/2: Saturation Index, Alarm: +/- 0.3,
Delay: 00:30:00. Probe Check: [No/Yes]
Dose Priority: [Simultaneous pH Priority]
Diagnostics: Software Rev, Meter Test {Auto Calibration),
Probe Test (Open Probe Test) Timers,
Chlorinator, Status Codes, Factory Reset, Self Test Sequence
Hardware: pH Control: 1/2 Doser Type [Internal Pump, External/Relay,
CO2 Ext/Relay, None] - pH Control 2/2 Flow: xx GPD
See page 22 for details
IntelliChem™ Installation and User’s Guide
10
Navigating IntelliChem Menus
The following examples show how to navigate the main menus and sub-menus. Press the MENU button to access the main menu. Press the
menu item and select items in a sub-menu. Press
page. To change a menu setting or value press the
the MENU button to exit and return to the previous menu items. Note: Settings are automatically save when changed.
Example: To change the pH dosage settings (pH Dosage screens 1/2 and 2/2):
Press MENU
pH Menu
ORP Menu
Saturatn Index
Auto Setup
ORP Menu
Saturatn Index
Auto Setup
Configuration
pH Dosage
pH Setpt: 7.5
pH Tweak
pH Supplies
1.
Press the
/ Up/Down arrow button to scroll through the main menu items. For this example choose pH menu.
2.
Press the
Right arrow button to select the pH menu.
3.
Press
arrow button to select pH Dosage (page 1 of 2). Press
/ to toggle between pH Dosage page 1/2 and page 2/2.
4.
From pH Dosage page 1/2, press the
to select
Dose (feed method). To change the feed method press
/ to change the selection: “by Volume” or
“by Time”.
pH Dosage 1/2
Dose: by Volume
Mixing Time:
H:00 M:59
5.
Press the
to select the next item. The cursor moves down to the “Mixing Time” hours setting
(H:00).
pH Dosage 2/2
Dose Limit Units
3 21 [oz]
Clear [Power-On]
6.
Press the
/ to adjust the Mixing Time hours between feeding acid. Press
to select the minutes. Press
/ to adjust the minutes. After adjustment, the display shows the new setting. Note: Press either
/ button to scroll forward or backwards within this sub-menu.
7.
Select 1/2 page indicator. Press the
/ buttons to select the next pH Dosage screen (2/2).
pH Dosage 1/2
Dose: by Volume
Mixing Time:
H:09 M:59 pH Menu
ORP Menu
Auto Setup
Configuration
8.
Use
/ buttons and / buttons to select and change the “Dose” (amount of liquid dispensed before waiting for a mix time), Limit (amount of liquid dispensed in one day, Units (apply to dose and limit) and clear dose limits setting.
9.
Press the MENU to return to the previous pH
Dosage page 1/2 menu items.
10. Press the MENU again to exit pH Dosage menu.
pH OK 7.46
Mixing 00:07:03
ORP OK 450
Mixing 00:07:54
Note: All settings are immediately save when changed.
IntelliChem™ Installation and User’s Guide
11
Menu Description
pH Menu
pH Menu
ORP Menu
Saturatn Index
Configuration
pH Dosage
pH Setpt: 7.2
pH Tweak
pH Supplies
pH Dosage 1/2
Dose: by Time
Mixing Time:
H:00 M26
by Volume
pH Dosage 2/2
Dose Limit Units
1200 64100 [mL]
Clear [Manual] by Time
pH Dosage 2/2
Dose 00:33:45
Limit 04:14:00
Clear [Power-On] by Setpoint
pH Dosage 2/2
Dose to Setpoint
Limit 00:08:00
Clear [24hr ]
To access the pH Menu:
Press MENU
screen 1/2 displays the current dose method (by Volume, Time or to Setpoint).
pH Dosage (for Internal and External Pumps)
pH Dosage (page 1/2)
Mixing Time: Select the amount of time in hours and minutes that IntelliChem will wait in between pH feeding. It should be set to allow sufficient mixing time for the chemicals to become distributed throughout the pool. The pH Mixing Time is set by Auto Setup.
Dose (by Volume/Time): Choose the feed method: “by Volume” and “by Time” are available choices for liquid dosers, as determined by the hardware setup. If CO2 is selected, then the available choices are “by Time” and “To Setpoint”.
pH Dosage (page 2/2)
Dose (Volume): Displays the current dose size (0-9999) in ounces [oz] or milliliters [ml].
Set the amount of ounces (or milliliters) that IntelliChem will feed pH (acid) each time
IntelliChem calls for pH chemicals. The Dose (Volume) is set by Auto Setup wizard based on pool volume and filter run time.
Dose (Time/Setpoint): Displays the current pH dose (feed) time. Sets the amount of time in hours, minutes and seconds that IntelliChem will feed pH (acid) each time IntelliChem calls for pH chemicals. The pH dose time is set by Auto Setup. The Dose (Time) is set by
Auto Setup wizard based on pool volume and filter run time. Dose (to Setpoint) does not have a dose amount, only a time limit.
Limit (Time/Volume): Displays the current feed limit. Sets the maximum amount of time/volume in hours, minutes and seconds or volumetric units that will be allowed to feed pH chemicals. As a safety feature, the IntelliChem will only allow a certain amount of pH chemicals to feed into the system in a 24 hour period. Set the maximum amount of time in hours (0-24) that will be allowed to feed. IntelliChem tracks each dose time, and adds them together. When the maximum dose time is reached or exceeded, the ORP feed system is prevented from feeding until the next 24 hour period begins, or when the feed timers are cleared manually. The default pH Limit is based on a safe limit of 2 ppm of the size of the pool, up to a 5 oz maximum. The Limit (Time/Volume) is set by Auto Setup wizard based on pool volume and filter run time.
Continue on next page.
IntelliChem™ Installation and User’s Guide
12
pH Menu
(Continued) pH Dosage (page 2/2)
Continue
Clear: Select Power-On to clear the pH dose limit time when IntelliChem is powered on.
Select Manual to manually clear the pH dose limit timers and select 24 Hrs to clear timers automatically each 24 hour period of continuous operation.
To protect the pool water, IntelliChem will automatically shutdown pH and ORP feed control and display an alarm message if IntelliChem (or any other dispensing device) runs non-stop for more than the selected Limit time or volume. This prevents IntelliChem from non-stop feeding pH reducer, because of a sensor error or external problem with the pool. This allows you to evaluate the pool chemistry before continuing with pH feeding.
pH Set Point
Displays the current pH set point value. Adjust the pH set point to meet pool and spa chemistry standards. The adjustable range is from 7.2 to 7.6 in increments of 0.1. The default pH set point value is 7.5.
To adjust the acid feed pH set point: Press MENU pH Menu
Press
Note: When using CO2, parameters are the same as above.
pH Tweak
The exact reading of each individual pH sensor can vary because of water makeup and variances in probe condition age, etc. The pH Tweak menu feature allows you to adjust the pH sensor reading to match the manual reading taken. The adjustable range is +/-
0.3. After adjusting the pH value, the main screen should now display the same value as the manual reading.
To adjust the pH sensor level:
Press MENU
pH Menu
The current value is displayed (reading = x.xx). Press
(+/- 0.3). To remove the tweak, set the level back to 0 (zero).
pH Supplies
pH Supply (page 1/2)
Units: Select gal-US, gal-UK, Liters or Time (hours/minutes)*.
Chemical: Use Acid, (pH -) or Base (pH+).
pH Supply 1/2
Unit: USGal
Chemical:
[Acid, pH-]
pH Supply 2/2
Capacity:
4.00 gal-US
Gauge: 3
pH Supply 2/2
Reminder in:
H:1000 M:00
Gauge: 6
IntelliChem™ Installation and User’s Guide
13
pH Menu
(Continued) pH Supply (page 2/2)
Capacity: Select from 0 to 200 maximum gal-US, gal-UK, or Liters.
*Time (Reminder in: H:xxx M:xx) If the supply Units were set to Time, the Capacity feature becomes a Reminder feature, as in an egg-timer. This can be used to trigger an alarm, based on cumulative feed times as to when to check the CO2 cylinder. Set the reminder time in hours (0-8760) and minutes (00-59) on ORP Supply page 2/2. Note:
Entering the hours and minutes time (H:00 M:00) will display the hour glass icon on the main screen.
Level Gauge (liquid only): Displays level gauge when using liquid chemical doser. Tank icon symbol is used for liquid chemical configurations that include valid supply and doser feed rate information.
pH Sensitivity
IntelliChem can adjust the feed times for pH depending on how close the current reading is to the set point. This helps to prevent overshooting and makes it easier for IntelliChem to reach the exact set point.
Low= (default) Full dose at 0.5 pH above setpoint
High= Full dose at 0.2 pH above setpoint
Off= Full dose at 0.005 pH above setpoint
For example: When set to LOW (full dose at 0.5 above setpoint), if pH setpoint is 7.2 and pH reading is 7.7 or above, a full dose amount is dispensed. As the pH comes closer to setpoint, say 7.45 (0.25 above setpoint - or- half the 0.5 pH value), the dispensed amount will be 1/2 of the specified dosage. And, at 0.05 (1/10th of 0.5 value) above setpoint
(7.25), the dosage will be 10% of that specified in the dosage menu. In that case, if the dosage was specified to be 10 ounces, IntelliChem will dispense only 1 ounce at a time.
This can be confusing to someone who is watching the IntelliChem because it will appear to not be dosing the full amount; therefore, in the Advanced display mode, the process timer will be shown as "%Dosing 0.1 oz", the "%" indicating that the dosage is reduced due to this Sensitivity feature.
To set the pH Sensitivity level: Press MENU - pH Menu
/ pH Sensitivity
pH Alarms
IntelliChem automatically displays a screen message indicating the pH level has reached or exceeded the HIGH (7.8) or LOW (6.8) pH alarm level settings.
IntelliChem will automatically set a high and low alarm for the pH level. The Delay time is the amount of time between the detected alarm condition and when IntelliChem displays the alarm message on the main screen. The Delay setting is adjusted in increments of 15 seconds.
To set the pH alarm “High” level and “Delay” time (page 1/2):
Press MENU pH Menu
(page 1/2 is High Level Alarm, page 2/2 is Low Level Alarm)
Press
To set the pH alarm “Low” level and “Delay” time (page 2/2):
Press MENU
Press
IntelliChem™ Installation and User’s Guide
14
ORP Menu
ORP Dosage (dispense chlorine or bromine)
pH Menu
ORP Menu
Saturatn Index
Configuration
ORP Dosage
ORP Setpt: 700
ORP Tweak
ORP Supply
ORP Dosage 1/2
Dose: by Time
Mixing Time:
H:00 M26
by Volume
ORPDosage 2/2
Dose Limit Units
1200 64100 [mL]
Clear [Manual] by Time
ORPDosage 2/2
Dose 00:33:45
Limit 04:14:00
Clear [Power-On] by Setpoint
ORPDosage 2/2
Dose to Setpoint
Limit 00:08:00
Clear [24hr ]
To access the ORP Menu:
Press MENU
ORP Dosage screen 1/2 displays the current dose method (by Time or to Setpoint).
ORP Dosage (for Internal and External Pumps)
ORP Dosage (page 1/2)
Mixing Time: Select the amount of time in hours and minutes that IntelliChem will wait in between ORP dosing. It should be set to allow sufficient mixing time for the chemicals to become distributed throughout the pool. The ORP Mixing Time is set by Auto Setup.
Dose (by Volume/Time): Choose the feed method: “by Volume” and “by Time” are available choices for liquid dosers, as determined by the hardware setup. If IntelliChlor
(SCG) is selected, then the available choices are “by Time” and “To Setpoint”.
ORP Dosage (page 2/2)
Dose (Volume): Displays the current dose size (0-9999) in ounces [oz] or milliliters [ml].
Set the amount of ounces (or milliliters) that IntelliChem will dose ORP (chlorine/ bromine) each time IntelliChem calls for ORP chemicals. The Dose (Volume) is set by
Auto Setup wizard based on pool volume and filter run time.
Dose (Time/Setpoint): Displays the current ORP dose (feed) time. Sets the amount of time in hours, minutes and seconds that IntelliChem will feed ORP (chlorine/bromine) each time IntelliChem calls for ORP chemicals. The ORP dose time is set by Auto Setup.
The Dose (Time) is set by Auto Setup wizard based on pool volume and filter run time.
Dose (to Setpoint) does not have a dose amount, only a time limit.
Limit (Time/Volume): Displays the current feed limit. Sets the maximum amount of time/volume in hours, minutes and seconds or volumetric units that will be allowed to feed ORP chemicals. As a safety feature, the IntelliChem will only allow a certain amount of ORP chemicals to feed into the system in a 24 hour period. Set the maximum amount of time in hours (0-24) that will be allowed to feed. IntelliChem tracks each dose time, and adds them together. When the maximum dose time is reached or exceeded, the
ORP feed system is prevented from feeding until the next 24 hour period begins, or when the feed timers are cleared manually. The default ORP Limit is based on a safe limit of 2 ppm of the size of the pool, up to a 5 oz maximum. The Limit (Time/Volume) is set by Auto
Setup wizard based on pool volume and filter run time.
Clear: Select Power-On to clear the ORP dose limit time when IntelliChem is powered on. Select Manual to manually clear the ORP dose limit timers and select 24 Hrs to clear timers automatically each 24 hour period of continuous operation.
IntelliChem™ Installation and User’s Guide
15
ORP Menu
(Continued)
ORP Set Point
Displays the current ORP set point value. Adjust the ORP set point to meet pool and spa chemistry standards. The adjustable range is from 650 to 800 in increments of 10. The default ORP set point value is 700.
To adjust the ORP set point: Press MENU ORP Menu
Press
Note: When using IntelliChlor SCG, parameters are the same as above.
ORP Tweak
The exact reading of each individual ORP sensor can vary because of water makeup and variances in probe condition age, etc. The ORP Tweak menu feature allows you to adjust the ORP sensor reading to match the manual reading taken. The adjustable range is +/-50mV. After adjusting the ORP value, the main screen should now display the same value as the manual reading.
To adjust the ORP sensor level:
Press MENU
The current value is displayed (reading = x.xx). Press
level (+/- 50 mV). To remove the tweak, set the level back to 0 (zero).
ORP Supplies
ORP Supply (page 1/2)
Units: Select gal-US, gal-UK, Liters or Time (hours/minutes)*.
Chemical: Use Chlorine or Bromine.
ORP Supply 1/2
Unit: USGal
Chemical:
[Chlorine]
ORP Supply 2/2
Capacity:
4.00 gal-US
Gauge: 3
ORP Supply 2/2
Reminder in:
H:1000 M:00
Gauge: 6
ORP Supply (page 2/2)
Capacity: Select from 0 to 200 maximum gal-US, gal-UK, or Liters.
*Time (Reminder in: H:xxx M:xx) If the supply Units were set to Time, the Capacity feature becomes a Reminder feature, as in an egg-timer. This can be used to trigger an alarm, based on cumulative feed times as to when to clean the SCG plates. Set the reminder time in hours (0-8760) and minutes (00-59) on ORP Supply page 2/2. Note:
Entering the hours and minutes time (H:00 M:00) will display the hour glass icon on the main screen.
Level Gauge (liquid only): Displays level gauge hour when using liquid chemical doser.
Tank icon symbol is used for liquid chemical configurations that include valid supply and doser feed rate information.
IntelliChem™ Installation and User’s Guide
16
ORP Menu
(Continued)
ORP Sensitivity
IntelliChem can adjust the feed times for ORP depending on how close the current reading is to the set point. This helps to prevent overshooting and makes it easier for
IntelliChem to reach the exact set point.
Low= (default) Full dose at 50mV below setpoint
High= Full dose at 20mV below setpoint
Off= Full dose at 1mV below setpoint
For example: When set to LOW (full dose at 50mV below setpoint), if ORP setpoint is 700 and ORP reading is 650 or below, a full dose amount is dispensed. As the ORP comes closer to setpoint, say 675mV (25mV below setpoint - or- half the 50mV value), the dispensed amount will be 1/2 of the specified dosage. And, at 695 (1/10th of 50mV value) below setpoint (700), the dosage will be 10% of that specified in the dosage menu. In that case, if the dosage was specified to be 10 ounces, IntelliChem will dispense only 1 ounce at a time. This can be confusing to someone who is watching the
IntelliChem because it will appear to not be dosing the full amount; therefore, in the
Advanced display mode, the process timer will be shown as "%Dosing 0.1 oz", the "%" indicating that the dosage is reduced due to this Sensitivity feature.
To set the ORP Sensitivity level: Press MENU - ORP Menu
/ ORP Sensitivity
ORP Alarms
IntelliChem automatically displays a screen message indicating the ORP level has reached or exceeded the HIGH (750 mV) or LOW (650 mV) pH alarm level settings.
IntelliChem will automatically set a high and low alarm for the ORP level. The Delay time is the amount of time between the detected alarm condition and when IntelliChem displays the alarm message on the main screen. The Delay setting is adjusted in increments of 15 seconds.
To set the ORP alarm “High” level and “Delay” time (page 1/2):
Press MENU ORP Menu
(page 1/2 is High Level Alarm, page 2/2 is Low Level Alarm)
Press
To set the ORP alarm “Low” level and “Delay” time (page 2/2):
Press MENU
Press
IntelliChem™ Installation and User’s Guide
17
Configuration Menu
Pool Details
From this menu, you can set your pool size, units to display and the daily run time which should match your daily pool pump filtration time.
Volume: Pool volume (size). Select range is 200 - 230,000 gal (gal-US, gal-UK and
Liters).
Units: Select units to display in English (gal-US), (gal-UK) and Metric Liters.
Daily: This daily run time is used for calculating dose and mix times. It is set and used in the Auto Setup script and should be the amount of time the pool pump/filter runs each day.
To access the Pool Details menu:
Press MENU
Display Modes
Mode: Selects which display mode is displayed: Basic or Advanced, Basic mode displays the current pH and ORP levels with any alarms and fuel gauge if enabled.
Advanced mode displays high resolution pH and ORP levels and process messages, timers (see page 6).
LEDs: Adjusts the brightness level (0-100%) of the front panel LEDs.
Menu: Adjusts the amount of time (minutes/seconds) the menu will be on each time the control panel is activated and also the time the entered password is valid.
BkLt: Adjusts the amount of time (hours/minutes) the controller screen backlight will be on each time the control panel is activated.
To access the display mode menu: Press MENU
Press
Delays (minutes)
Power-On: Sets the delay time from power up to the first display screen reading. The adjustable time is from 1 to 60 minutes. The default power on time is 14 minutes
Flow Switch: Sets the delay time from when the Flow Switch is active to the first display screen reading. The adjustable time is from 1 to 60 minutes. The default flow switch delay time is one minute.
Doser/Probe: Sets the delay time from when the Doser turns on to when it takes the next probe measurement. Adjustable time is 0 to 60 seconds. Default is 15 seconds.
Use longer times to prevent interaction of doser from affecting the measurement.
To access the delays menu: Press MENU
Press
IntelliChem™ Installation and User’s Guide
18
Configuration Menu
(Continued)
Set Password
IntelliChem menus, the pH button and ORP button on the control panel can be password protected. Once a password has been set, IntelliChem will not allow access to the menu system and no changes to be made without entering the password. For more information see page 5.
PW: Enter a four digit password [0000]. Each digit can be assigned 0-9.
Lock: Select OFF, MENU (password protect the main menu) or ALL (password protect all control panel buttons. Once the password is entered, access is granted for the duration specified by the Menu timeout setting in the Configuration/Display Mode menu. If the menus are locked, changes via the automation interface will also be locked out.
To access the password menu:
Press MENU
Press
password, first try the default password 1234, then call Customer Support for assistance.
Preferences (1/2)
To access the delays menu: Press MENU
Press
/ to adjust the following settings.
Preferences 1/2 pH Lockout: 7.8
Probe Check: No
pH Lockout: is the pH reading at which IntelliChem will no longer dose sanitizer
(Chlorine/Bromine). Above pH of 7.8 it is generally understood that the ORP reading is suppressed and therefore will not be used to administer additional sanitizer. Just bringing the pH level down will raise the available chlorine and the effective ORP. At this trip point, an alarm message will be shown on the screen and ORP doses will cease.
Range is 7.7 to 8.2, default is 7.8.
Probe Check: Enables the Open Probe Test which can determine if the pH and ORP sensor probes are disconnected or non-functional. Although it will not help determine if probes need cleaning, it will catch many types of conditions including bad wiring, disconnected cable, and open/broken probe sensor. If enabled, this feature tests the probes before starting each dose. This validates that the readings used to determine that the dose is required were accurate. If disabled, the probes should periodically be tested with the Configuration/Diagnostics/Probe Test menu item. Check all connections and replace the probes and cables if necessary.
IntelliChem™ Installation and User’s Guide
19
Configuration Menu
(Continued)
Preferences (2/2
)
Preferences 2/2
Saturation Index
Alarm: +/- 0.3
Delay: 00:30:0
Saturation Index
Alarm: +/- 0.3: If the Saturation Index (SI) level is in the “Corrosive” or “Scaling” range, this feature allows you to enter a Saturation Index (SI) alarm threshold value between +/-
0.1 to +/- 0.9 (+/- 3 default). Select “Disabled” to disable the Alarm feature.
Delay: The Alarm Delay feature sets the delay time before the SI Alarm (see above) message is displayed. Enter the delay time from 00:15:00 to 24:00:00 (30 minutes default). Note: Once the SI has passed the threshold for the delay period, an alarm message is displayed showing the Saturation Index Alarm (along with other pH alarms) that includes the value and description.
pH >OK 7.44
-.72 Corrosive
ORP OK 730
Monitoring pH >OK 7.44
+.32 Scaling
ORP OK 730
Monitoring
These alarm messages are also displayed on the IntelliTouch, EasyTouch and SunTouch control panel.
Dose Priority
To access the delays menu: Press MENU
Press
/ to select option.
Dose Priority: pH Priority or Simultaneous.
Depending on how the IntelliChem chemical dosers are plumbed and how much water is circulating in the system where the chemicals are injected into the water stream, it may be preferred to only feed Chlorine when Acid is not feeding. This would be the pH Priority setting.
" Simultaneous allows both chemicals to feed at the same time - and can be used when both feed systems are not liquid chemicals or the injectors are separated by a safe distance in the water stream. DANGER:
Combining liquid acid and chlorine can result in the formation of hazardous and explosive gas.
" pH Priority will always feed acid first, and only during the acid mix time or general monitoring period will the IntelliChem feed the liquid chlorine sanitizer. If while feeding chlorine, the pH rises above setpoint, the ORP dose will be stopped and allow acid to feed.
IntelliChem™ Installation and User’s Guide
20
Configuration Menu
(Continued)
Diagnostics
Software Rev: Displays the software revision.
Meter Test: Performs an internal self-test of the pH/ORP meter and sensing circuitry.
Ensures both circuits are performing properly First tests the High circuit in the uncalibrated state, waits for a button press, then tests the Low circuit and waits for a button press. Once these two tests complete, it proceeds with the self-calibration. A Pass or Fail message is displayed. If this test fails, disconnect power and check for water or dirt on the circuit board. Use a can of dry compressed air to clean the board if necessary.
If the test continues to fail, contact technical support.
Probe Test: This test takes approximately 30 seconds. Perform this test with the sensor cables and probes installed. Probes must be clean and in water. Possible results are :
Both Probes Good pH: Good ORP:Bad pH: Bad ORP:Good pH: Bad ORP:Bad
Timers: This displays the counters used for tracking the cumulating dose volume and/or time used in determining the Dose Limit. It shows:
"PCs" PH cumulative dose limit timer in Days HH:MM:SS
"Ocs" ORP cumulative dose limit timer in Days HH:MM:SS
"ml" Milliliters of cumulative dose for Ph and Orp (0-9999) stops at 9999 ml
"Run" the RUN TIME in Days, HH:MM:SS since powered up.
If you need to know how much you've dosed during a day, or how long its been running that day, “Timers” will have this information. The cumulative times/ml get reset when you clear the dose limits, The Run Time clears on power-up.
IntelliChem™ Installation and User’s Guide
21
Configuration Menu
(Continued)
Diagnostics
(Continued)
Chlorinator: This screen displays the current IntelliChlor (SCG) status, salt (ppm) levels and error conditions. The hexadecimal status value is decoded and displayed in the brackets on the bottom line; multiple error conditions are shown by sequencing through the messages.
This display can be used to determine if the SCG is connected and responding to the
IntelliChem. If the IntelliChlor is connected, this display may show "Please wait 2-7 minutes for ppm". This indicates the IntelliChlor is responding to initial contact but until water flow and sufficient salt level is reached, the IntelliChlor will not respond with further information like salt ppm and status. Sometimes it is helpful to cycle power on the
IntelliChlor and wait 10 minutes for the green lights before it will respond with ppm and status information; it may not respond if the Salt or Cell lights are flashing red.
If the Configuration / Hardware / ORP Control / Doser Type is set to IntelliChlor, the
IntelliChem will control the IntelliChlor as it would a doser, actively turning it on (100%) for chlorine demand, and off (0%) when the ORP reaches the desired set point.
For the Chlorinator to work when connected to an Automation controller like the
IntelliTouch, EasyTouch, or SunTouch, those units must be configured with the
IntelliChlor enabled. The displays is as follows:
--------------------------------------
Chlorinator Info:
Salt: 4500 ppm
Status Code=00H
[OK-NO ERRORS ] V
--------------------------------------
To get updated ppm, cycle SCG power and wait.
Press any button
--------------------------------------
Possible messages are:
No Flow
Low Salt
Very Low Salt
High Current
Clean Cell
Low Voltage
Cold Water
IntelliChem™ Installation and User’s Guide
22
Configuration Menu
(Continued)
Status Codes: This displays a complex series of values that indicate the real-time status and alarm conditions.
Top line, Codes: HA= is the automation Home Address that IntelliChem has locked onto.
In the upper-right corner,
R0,1,2,4 which represents the UOC comm status.
R0 = standalone (no KA from Automation since power up)
R1 = Found KA packets within 30 seconds of power up
R2 = Found KA packets later, after 30 seconds, so was operating in standalone for a while
R4= Was in Automation mode (sending IntelliChlor commands through IntelliTouch) but has dropped the connection.
The two-digit number (0-99) directly below the R# is the number of seconds it's gone without a valid KA packet. It should generally be 00-04 seconds. More than that means that IntelliChem is missing the automation KA packets.
Note: Status and Alarm hexadecimal displayed codes represent the current IntelliChem status. For further information, contact Technical Support (800) 831-7133.
Factory Reset: Clear all calibrated values and run Auto Setup to initialize IntelliChem.
For Factory Default Settings.
Self Test Sequence: Upon entering a self test sequence, all dosing will pause until the test is completed. Follow the on-screen prompts. “PASSED” indicates the test was successful. See Troubleshooting section for error conditions, on page 46.
Hardware
Most common hardware configurations can be selected by using the Auto Setup Wizard.
This menu allow more complex and custom settings.Use the Hardware menu to configure IntelliChem for the pH and ORP hardware controls and dose being used. Upon entering the hardware setup menu, all dosing will pause until the hardware setup is completed.
After pressing the Hardware button the following message is displayed.
Dosing will resume when you
_exit this menu_
Press any button
To access the hardware menu: Press MENU
pH Control
(page 1/2 - 2/2)
Doser Type 1/2: Select the pH Control Dose Type:
IntelliChem pH feed method being used (INTERNAL PUMP, EXTERNAL
RELAY, CO2 EXT/RELAY (Carbon dioxide tanks), NONE.
Doser Type 2/2:
INTERNAL PUMP: Right, MTR_R, Left, MTR_L
EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2
CO2 EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2
Flow (Rate) 2/2:
INTERNAL PUMP (MTR_R/MTR_L): FLOW: xxx GPD (gallons per day) -
(53, 65, 75).
EXTERNAL RELAY 1 or 2: RATE: xxx GPD (gallons per day). Note: Set to
0 to use time-based feed instead of volumetric (only on the Ext Relays
(not internal motors).
CO2 EXTERNAL RELAY 1 or 2: Use Time (0) or SCFH (1-400).
IntelliChem™ Installation and User’s Guide
Configuration Menu
(Continued)
ORP Control
(page 1/2 - 2/2)
Doser Type 1/2: Select the ORP control hardware:
IntelliChem ORP feed method being used (INTERNAL PUMP, EXTERNAL
RELAY, INTELLICHLOR Salt Chlorine Generator (SCG), NONE.
Doser Type 2/2:
INTERNAL PUMP: Right-Side (MTR_R), Left-Side (MTR_L)
EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2
INTELLICHLOR: All Models (IC20, IC40, IC60)
Flow (Rate) 2/2:
INTERNAL PUMP (MTR_R/MTR_L): FLOW: xxx GPD (gallons per day)
EXTERNAL RELAY 1 or 2: RATE: xxx GPD (gallons per day). Note: Set to
0 to use time-based feed instead of volumetric (only on the Ext Relays
(not internal motors).
Hardware settings must be chosen carefully. If both dosers are assigned to the same internal pump or external relay, the program will display an error message upon exiting the Hardware menu.
23
Alarm Output
Select the following IntelliChem alarm output information:
External alarm output: Ex_Relay1 or Ex_Relay2.
For an external alarm indicator, an unused relay may be selected to turn on when the red Alarm LED on the front panel is turned on.
The alarm relay must be chosen carefully. If Ex_Relay1 or Ex_Relay2 is used for a doser, it must not be used for an alarm output. Upon exiting the
Hardware menu, the program will check to be sure the same relay is not used more than once. If a relay is assigned to more than one function, an error message will be displayed.
error message:
--------------------------
Alarm Relay conflicts with
Ext Doser Relay
Changed to Ex_R1
-------------------------- or
Changed to Ex_R2
or
Changed to N/A
IntelliChem™ Installation and User’s Guide
24
Auto Setup
Auto Setup
See page 6 for details.
Sat Index
Saturation Index
The Saturation Index (SI), also called the Langelier Index, is a chemical equation or formula used to diagnose the water balance in the pool. The Saturation Index formula is SI = pH + TF + CF + AF - 12.1 (or 12.2 for salt pools). To calculate the
Saturation Index, you must first test the pool water for pH, temperature, calcium hardness, and total alkalinity. Refer to a chart for assigned values for your temperature, hardness, and alkalinity readings then add these to your pH value. Subtract
12.1 (or 12.2 for salt pools), which is the constant value assigned to Total Dissolved
Solids and a resultant number will be produced. A result between +/-0.3 indicates balanced water. Test results not within these values require chemical adjustments to achieve balance. This formula is more or less reliable but not guaranteed. In some cases, individual readings for pH, calcium, and Total-Alkalinity might be beyond normal recommendations, however, combined within the formula can produce “balanced water.” The SI is useful to pinpoint potential water balance problems.
To access the Sat Index menu:
Press MENU
/ Saturatn Index
Press
/ and /to adjust the Saturation Index values.
pH Menu
ORP Menu
Saturatn Index
Configuration
pH: 6.0 Temp: 77F
CH: 250 TDS1000
TA: 90 CYA:18
SI = -0.9 CORRSV
Sat Index Menu
Note: The pH, Temp, and TDS are entered automatically as the numbers are available from the measurement and automation system. Each time this display is entered, if available, the current temperature is obtained from the Automation controller
(IntelliTouch, EasyTouch, etc), TDS is obtained from the IntelliChlor SCG. But these values can be changed on this screen for calculation purposes.
pH: Enter the current pH value.
Temperature: Enter the current temperature setting.
CH: Enter the current calcium hardness level.
TDS: Enter the current Total Dissolved Solids level.
TA: Enter the current total alkalinity value.
CYA: Enter the current cyanuric acid value.
SI: Displays the last calculated SI value (Corrosive/Scaling/Ideal).
Note: If there is no flow or Flow Delay is enabled, no SI value displayed.
pH: 6.0 Temp: 77F
CH: 250 TDS1000
TA: 90 CYA:18
SI = N/A No Flow pH: 6.0 Temp: 77F
CH: 250 TDS1000
TA: 90 CYA:18
SI = N/A FlowDelay
IntelliChem™ Installation and User’s Guide
25
Sat Index
(Continued)
Recommended Pool Chemistry pH range:
ORP range:
Alkanlinity:
Calcium Hardness:
Cyanuric Acid/Stablizer:
7.2 to 7.6
650 to 750
80 to 120 ppm
200 - 500 ppm
30-50 ppm
pH: Chlorine produced by the IntelliChlor SCG is close to Neutral pH. However, other factors usually cause the pH of the pool water to rise. Therefore, the pH in a pool chlorinated by IntelliChlor tends to stabilize at approximately 7.8. This is within APSP standards. If the pool pH rises above 7.8, have a pool professional test to see if other factors such as high Calcium Hardness or Total Alkalinity are the cause and then balance accordingly.
Temperature: The pool water temperature can affect the saturation index value.
IntelliChem gets the temperature from the EasyTouch, IntelliTouch and SunTouch automation control system. The automation control system must have the POOL or SPA pump running to report the proper temperature to IntelliChem, otherwise IntelliChem will use its own menu's temperature value. To change the IntelliChem default temperature, select Temp and use the Up/Down arrow to adjust the temperature.
pH Level Test: Test the pH level of your pool water with a reliable test method. If necessary, adjust according to your pool professional’s recommendations. APSP’s recommended ideal range for pH is 7.2 to 7.6. Note: Never use dry acid (sodium bisulfate) to adjust pH in arid geographic areas with excessive evaporation and minimal dilution of pool water with fresh water. A buildup of by-products can damage the
IntelliChlor SCG
Calcium Hardness
Recommended range for calcium hardness is 200-500 ppm. Calcium Hardness levels should be tested weekly. Calcium hardness is the calcium carbonate scale deposited on pool surfaces. The test for Calcium Hardness is a measure of how
“hard” or “soft” the water is testing. “Hard” water can have high levels of calcium and magnesium. If these levels are too high the water becomes saturated and will leave calcium carbonate scale deposits (a “white-ish,” crystallized rough spot) on any surface inside the pool. If the levels are too low, the water becomes “soft” and will corrode surfaces inside the pool. Use TSP or Hydroquest 100 to lower Calcium
Hardness levels that are too high or add water to the pool which has a lower calcium hardness content. Levels which are too low require the addition of calcium chloride.
Total Dissolved Solids (TDS): Adding salt to pool water will raise the TDS level. While this does not adversely affect the pool water chemistry or clarity, the pool water professional testing for TDS must be made aware salt has been added to the IntelliChlor system. The individual performing the TDS test may then subtract the salinity level to arrive at a TDS level that would be compatible to a TDS reading for a non-salt water pool.
Note: If a salt chlorine generator is being used for your pool, the salt level is the TDS level of the pool.
IntelliChem™ Installation and User’s Guide
26
Sat Index
(Continued)
Total Alkalinity
APSP’s recommended ideal range for total alkalinity is 80 to 120 ppm for “gunite” and concrete pools and 125-170 ppm for painted, vinyl, and fiberglass pools. Test levels weekly and adjust according to your pool professional’s recommendations.
Total Alkalinity can be described as a buffer that keeps pH in order. pH depends on the ability of the total alkalinity in the water to withstand the changes in pH. If the total alkalinity is too high, adding acid (similar to pH) lowers the level. Adding a base (e.g sodium bicarbonate) when total alkalinity is low, raises the level. The level of total alkalinity in the water is a measurement of all carbonates, bicarbonates, hydroxides, and other alkaline substances found in the pool water.
Cyanuric Acid: Cyanuric acid is needed in outdoor pools to help to stabilize and maintain proper levels of chlorine. 90% of unstabilized chlorine is destroyed by the UV radiation from the sun. Cyanuric acid stabilizes chlorine in water from UV degradation.
When using the IntelliChlor SCG, the cyanuric acid level should be maintained between
30-50 ppm.
Optimum Pool Water Chemistry Conditions for Salt Water Pools
(using the IntelliChlor SCG)
In accordance with the Association of Pool and Spa Professionals (APSP) standards, it is recommended that the pool water chemistry conditions (see page 21) be maintained on an on going basis to help protect pool users, pool related equipment
and surfaces in and around the pool. These values are important to maintaining the pool equipment in proper operating condition and preventing corrosion, liming or other problems. The IntelliChlor Electronic Chlorine Generator is warranted to operate properly only if these conditions are met. For more information, refer to your local agency having jurisdiction, NSPI (National Spa and Pool Institute), the CDC (Centers for Disease
Control), or the WHO (World Health Organization). Recommended pool water chemistry is given below:
Free Chlorine: 2.0 - 4.0 ppm. Above 4.0 ppm may cause corrosion of metal components
Combined Chlorine (Chloramines): None (super chlorinate to remove all chloramines)
pH: 7.2 - 7.8 (USE MURIATIC ACID to lower pH and Soda Ash to raise pH.)
Cyanuric Acid: 30 - 50 ppm
Total Alkalinity: 80 - 120 ppm
Calcium Hardness: 200 - 400 ppm
TDS (includes salt): 3000 minium to 5700 to 6000 maximum ppm
Salt: 3000 - 4500 ppm (ideal 3400 ppm)
Metals (Copper, Iron, Manganese): None
Nitrates: None - Phosphates: Less than 125 ppb
Using the Langelier Saturation Index (LSI) to Diagnose Water
Balance
Use the Langelier Saturation Index (LSI) calculator to diagnose the water balance in your pool. Water with a LSI of 1.0 is one unit above a balanced condition. Reducing the factors by 1 unit will bring the water into equilibrium. To use the LSI calculator, refer to: http://www.pentairpool.com/pool-owner/resources/calculators/langelier/
IntelliChem™ Installation and User’s Guide
27
Sat Index
(Continued)
Calculating the Saturation Index
The saturation index is a formula that relates pH, calcium and alkalinity in the pool water.
A well balanced pool water will have a formula result range between -0.3 and 0.3
Outside this range, the pool water is out of balance, potentially damaging pool equipment or scaling the salt chlorine generator. The equation to calculate Si is:
SI = pH + CHF + AF + TF - TDSF
Saturation
Index pH as tested
Calcium
Hardness Factor
Alkalinity
Factor
Temperature
Factor
TDS Factor
(21.1 non-salt,
12.2 salt pools)
Cyanuric acid in the form of cyanurate ions contribute to alkalinity. Thus, a correction must be made to total alkalinity. We subtract 1/3 of the cyanuric acid level from the reading obtained in the total alkalinity test.
Total Alkalinity - 1/3 Cyanuric Acid = Corrected Alkalinity
This correction can be considerable in established pools with high cyanuric acid levels; for example, at 240 ppm cyanuric acid, the correction amounts to 80 ppm (240 ÷ 3 = 80).
Saturation Index Tables (as recommended by NSPF)
IntelliChem™ Installation and User’s Guide
28
INSTALLATION
(INTELLICHEM AND FLOW CELL)
Installing the IntelliChem
Before installing the IntelliChem controller, read the following instructions.
1.
IMPORTANT! If the equipment pad is below the water level of the pool, please install a CHECK VALVE after the heater or use a Hartford Loop.
2.
Identify new and existing equipment to be connected.
3.
Decide if the sensors will be in a separate bypass line, or if the Flow cell will be used. Caution: If the Flow Cell is being installed, the input water
maximum pressure is 25 PSI.
4.
Determine the supply voltage, 110 VAC or 220 VAC, and wire the transformer wires as needed (see page 30).
5.
Determine if the control to the equipment uses the same voltage as the supply voltage. All controlled equipment must be compatible.
6.
Determine the water-tap points for the flow cell bypass inlet and outlet.
7.
Install the Flow Cell away from direct sunlight and on a flat vertical surface.
8.
Switch the main house circuit breaker OFF. Connect the supply voltage to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/ power center (see page 40 for IntelliChem AC power wiring diagram).
This ensures that IntelliChem will only dispense chemicals when the filter pump is ON. Note: IntelliChem must be connected to a separate dedicated circuit GFCI.
9.
If using a Flow Cell install the bypass now.
10. Connect the pH and ORP sensors.
11. Test the plumbing for leaks.
12. Switch on the IntelliChem system for the first time as described below.
Risk of Electrical Shock or Electrocution!
IntelliChem must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property.
Always disconnect the power to the IntelliChem enclosure at the circuit breaker before servicing the unit. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
IntelliChem™ Installation and User’s Guide
Mounting IntelliChem Enclosure
Mount the IntelliChem enclosure as follows:
1.
Select a location for mounting the IntelliChem enclosure with the following required recommendations:
2.
Install the IntelliChem enclosure at least 10 feet from the pool or spa wall.
3.
Supply power must be routed to the IntelliChem in accordance with the applicable national and local (NEC) codes (see page i).
4.
The installation surface must be solid and vertical. Do not mount the
IntelliChem enclosure in a horizontal position.
5.
Maintain adequate clearance for opening the enclosure.
6.
The environment should be free of chemical fumes and excessive heat.
The maximum temperature it should not exceed is 110 ºF (50 C).
7.
Mount as far as possible from sources of electrical interference.
8.
Mount the enclosure on a flat surface.
9.
Hold the IntelliChem enclosure against the mounting surface with a closed lid and mark the location of the mounting brackets located on the sides of the enclosure next to the wall. Prepare holes as necessary and secure enclosure using the provided mounting screws.
10. Install a conduit into the controller enclosure.
Locate the chemical feed pumps and the chemical storage tanks in a safe and secure area. Never turn the chemical feed pumps on when both flow cell valves are closed. Increased pressure may cause the feed lines to blow off and spray full strength chemicals on anyone or anything near the equipment. Securely fasten all electrical, water, and chemical lines.
29
MOUNTING
HOLES
Menu Select
Alarm
MOUNTING
HOLES
IntelliChem™ Installation and User’s Guide
30
Wiring the IntelliChem Transformer for 120 VAC or 240 VAC
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect AC power to IntelliChem at the circuit breaker before servicing. Failure to do so could result in death or serious injury to installer, serviceman, pool users, or others due to electrical shock.
High Voltage Wiring
The high voltage wiring compartment is located inside the IntelliChem enclosure. The
IntelliChem system can be connected either to 120 VAC or 240 VAC. The IntelliChem system should be wired to receive power from the filter pump relay. The maximum current rating is 200/100 mA at 120/240 VAC (60 or 50 Hz). Connect the AC power supply voltage to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for IntelliChem AC power wiring diagram). There is no ground/bonding terminal required at this non-metallic enclosure. Follow manufactures instructions when installing and testing of ground fault circuit breakers (GFCB) and interrupters (GFCI).
Connect input AC wires to the IntelliChem transformer wires as follows:
• 120 VAC: Connect one 120 VAC source wire to the Brown/Black wires connected together and one wire to the Blue/White wires connected together.
• 240 VAC: Connect one 240 VAC source wire to White wire and one wire to Brown wire. The Black/Blue wires are connected together.
240 VAC
120 VAC
IntelliChem™ Installation and User’s Guide
EX_RELAY 2
EX_RELAY 1
31
Connecting External Devices to IntelliChem
External Devices such as pumps, CO2 devices and alarms can be connected to either of the dry contact relays (EX_RELAY 1 and EX_RELAY 2). Relay contact ratings:
5 AMPS, 250VAC/30VDC located on the IntelliChem circuit board. See wiring diagram below and “Plumbing Installation” on page 37.
BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS
BEFORE SERVICING INTELLICHEM. AC Power may be supplied to the relay terminals Ex_Relay1 and Ex_Relay2 from other sources.
Wiring external devices must be performed by a licensed certified electrician or a qualified pool professional in accordance with the National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code
(CEC), CSA C22.1. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property.
120 VAC
240 VAC
EXTERNAL DEVICES
Alarms and external pumps option:
1 pump (acid feed)
2 pump
(acid/chlorine feed)
Acid
Pump
Chlorine
Pump
EXTERNAL DEVICE
EX_RELAY 1
EX_RELAY 2
External Devices:
EX_RELAY 1 and
EX_RELAY 2, contact ratings:
5 AMPS,
250 VAC/30 VDC
LINE
NEUTRAL
GROUND
120 VAC
SUPPLY
CO2
Tank
CO2 Kit
P/N714000070
EXTERNAL DEVICE
-
+
VDC
LOW
VOLTAGE
SUPPLY
External Device Wiring Diagram
IntelliChem™ Installation and User’s Guide
32
Installing the Flow Cell and pH/ORP Sensors (Kit Contents)
pH and ORP sensors are shipped with a protective cap covering the electrode tip of the probes to protect the sensing element. DO NOT MIX THESE CAPS - Solutions will destroy the other type of probe. Sensors should be kept in the protective cap until ready for installation, if the sponge in the boot becomes dry, wet it with pool water. Before using the sensor remove the cap.
IntelliChem Kit Contents
4
5
3
2
1
3
2
6
6
3
1
2
1
1
1
4
5
6
7
8
9
10
11
12
13
Item # Qty. Part # Description
1 3
2 3
3 3
1
IntelliChem™ Installation and User’s Guide
9
8
7
6
Mounting the Flow Cell
Remove Flow Cell from shipping carton and select a suitable location for the flow cell within 10 feet of the IntelliChem controller.
Note: The 3/8” flexible tubing that is required to connect the flow cell to the rest of the system is included with IntelliChem kit.
33
Mounting holes
Flow
Switch
Magnet
Flanged end down
Installing the pH and ORP Sensors (Read This First)
Install the pH and ORP sensors as follows: For IntelliChem Plumbing Installation
Diagram, see page 37.
1.
Sensors wires will connect to within 10 feet.
2.
Water leaks will cause damage! Mount where water does not leak and damage other components.
3.
Mount flow cell vertically with provided screws.
4.
Securely fasten all electrical, water and chemical lines.
5.
Locate chemical feed pumps and chemical storage tanks in a safe and secure area.
6.
Maximum operating pressure = 25 psi.
7.
Extreme pressure variances may affect readings and can cause damage to the sensors.
8.
Avoid installing the outlet before the main pump as the vacuum may damage the chemical sensors.
9.
Only inject chemicals on the outlet side of the IntelliChem Flow Cell
10. Do not over tighten fittings on flow cell top.
IntelliChem™ Installation and User’s Guide
34
Installing the pH and ORP Sensors
To install the Flow Cell pH and ORP sensors:
1. Keep pH and ORP sensors wet at all times, install the sensors into the flow cell. Hand-tighten only and save caps for future use (DO NOT MIX
THESE CAPS), fill flow cell with water. The sensors have O-Rings and don’t require Teflon ® tape.
• Do not rub hard on the glass element in the sensor or use sand paper or other polishing material to clean.
• Handle electrode carefully.
• Sensors contain external and internal glass elements.
• Do not drop or otherwise subject the sensor to vibration, physical impact.
To avoid permenant damage of sensors or flow cell, do not use during freezing conditions.
• Leave excess wire outside the controller enclosure. If the cable is longer than needed, it should be coiled neatly and attached under the controller enclosure.
• DO NOT CUT THE SENSOR WIRES. Do not stuff excess wire inside the controller as this may cause excess strain on sensor and relay connections.
pH Sensor
ORP Sensor
IntelliChem™ Installation and User’s Guide
Plumbing the Flow Cell
Be sure to have a licensed plumber perform all plumbing; this is important, as they will be familiar with all of the codes in the local area.
To connect the Flow Cell to the system plumbing: See page 37 for plumbing diagram.
1.
At the equipment pad, switch off the filter pump and release the pressure from the system by opening the valve on top of the filter.
WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling into any pipes. Securely fasten all electrical, water and chemical lines. Locate chemical feed pumps and chemical storage tanks in a safe and secure area.
2.
Close all valves to prevent flooding.
3.
Attach the IN and OUT tubes to the Flow Cell Inlet and Outlet
(see Tubing Installation Diagram shown below).
4.
Run the end of the IN tube to the chosen pressure line. Choose a location that provides enough space to drill and to tighten the clamp
(must be after the filter, but before the heater). Be sure the tube is not pinched or kinked. Mark a spot on the pipe.
5.
Locate where the water will be supplied from and returned for each flow cell. The most common location for the water inlet to the flow cell is
AFTER the main filter and BEFORE the heater. See page 37.
6.
Drill a 3/8” hole for the flexible tubing fitting on the mark and immediately place the fitting into the pipe. Align pipe clamp with the fitting and tighten the pipe clamp.
7.
Run the end of the OUT tube (with the pipe clamp) to the chosen return line. Choose a location that provides enough space to drill and to tighten the clamp (must be after the heater - see page 37). Be sure the tube is not pinched or kinked. Mark a spot on the return line pipe.
8.
Drill a 3/8” hole for the flexible tubing fitting on the mark and immediately place the fitting into the pipe. Align pipe clamp with the fitting and tighten the pipe clamp.
9.
Open any closed system valves. Close the filter valve and turn on the circulation system. Check that the system is working properly.
Tubing
3/8"
Drill
Pipe
Clamp
35
Pipe
IntelliChem Tubing Installation Diagram
IntelliChem™ Installation and User’s Guide
36
Plumbing the Flow Cell
(Continued)
Do not inject acid directly in to the flow cell. Injecting acid in this way will result in incorrect reading which may damage the existing pool equipment.
10. Locate the chemical injection points.
11. Prepare and install the chemical injector fittings.
12. Install the chemical storage containers.
13. Turn ON the main circulation pump.
14. Check for leaks and verify the flow sensor indicates flow.
Flow Cell Inlet and Exit Lines
1.
It is essential that the supply line be at a higher pressure than the discharge line so the water will flow through the cell at a steady rate in the right direction.
2.
Inlet should be installed after filter and before heater.
Note: Plumb the
INLET before the solar valve.
3.
Exit should be installed after heater and as far away from any equipment as possible.
Make sure all pumps are OFF before drilling into pipes.
Never switch ON chemical feed pumps without the pool filter pump also running.
The flow switch is a dry contact only (no current). Use with any other brand of flow switch voids WARRANTY and UL listing.
IntelliChem™ Installation and User’s Guide
IntelliChem Installation Plumbing Diagram
37
IntelliChem™ Installation and User’s Guide
38
Connecting the pH and ORP Sensors Wires to IntelliChem Circuit Board
The Flow Switch is a Dry Contact Only (No Current). This Flow
Switch should only be used with IntelliChem. Use of this Flow
Switch with any other brand of controller will void the warranty and
UL listing.
1.
Route the Flow Cell switch wires into the IntelliChem enclosure through the strain relief and connect the wires to J6 Sensor terminal connector on the IntelliChem circuit board. Connect the BLACK wire to the GND
screw terminal and the RED wire to the FLOW screw terminal.
2.
Route the pH and ORP sensor wires into the IntelliChem enclosure through the strain relief and connect to J6 Sensor terminal connector on the IntelliChem circuit board. The sensor wires are labeled. PLUS AND
MINUS POLARITY MUST BE OBSERVED.
pH sensor wire: Connect the GREEN to the pH - screw terminal and the
CLEAR wire to the pH + screw terminal.
ORP sensor wire: Connect the GREEN to the ORP - screw terminal and the CLEAR wire to the ORP + screw terminal.
J6
SENSORS
J7
COM Port
EX_RELAY 2 EX_RELAY 1
DRY CONTACTS TO EXTERNAL DEVICES
(Connect wires in front - See Manual for details)
pH PROBE
ORP PROBE
FLOW SWITCH
OPEN
+ DATA
- DATA
GND
To Automation or IntelliChlor
Power Center
COM Port
Figure 2: IntelliChem J6/J7 Circuit Board Wiring Connections
3.
Turn the main pump on and open the valves to test for leaks and the free movement of magnet. Magnet must be all the way up in order to close the flow switch. 1/4 GPM will push the magnet all the way up.
Make sure that all pumps are off before drilling into any pipe.
Never turn chemical feed pumps on when either flow cell valve is closed.
IntelliChem™ Installation and User’s Guide
CONNECTING INTELLICHEM TO AN AUTOMATION CONTROL SYSTEM
Wiring IntelliChem AC Power to Filter Pump Relay
IntelliChem AC Power Wiring Instructions:
When using IntelliChem as a stand alone device (with a time clock) or with an IntelliChlor salt chlorine generator, IntelliChem MUST BE CONNECTED TO THE PUMP SIDE OF THE
MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for
IntelliChem AC power wiring diagram). This ensures that IntelliChem will only dispense chemicals when the filter pump is ON.
For IntelliTouch ® , EasyTouch ® or SunTouch ® automation control system using an IntelliFlo ® pump (or 2-speed pump) and an IntelliChlor ® (SCG), the IntelliChlor
AC power center wires must also be connected to the PUMP SIDE OF THE
MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for diagram). This ensures that IntelliChem and IntelliChlor only produce chlorine when the main filter pump is on.
The following wiring diagram (see next page) shows the IntelliChem AC power wiring and COM port connections to the EasyTouch, IntelliTouch and SunTouch automation control system.
39
IntelliChem™ Installation and User’s Guide
40
IntelliChem AC Power and COM port (RS-485) Wiring Diagram
J6
J7
COM Port
EX_RELAY 2 EX_RELAY 1
IntelliChem AC Power
(connects to filter pump relay)
EasyTouch, IntelliTouch
Load/Power Center
Circuit Board
IntellilFlo
Pool Filter Pump
COMMUNICATION CABLE
IntelliChlor Power Center
(wired for 120 or 240 VAC)
EASYTOUCH, INTELLITOUCH, SUNTOUCH
LOAD/POWER CENTER
PUMP FILTER RELAY
TO AUX PLUG (FILTER PUMP)
ON CIRCUIT BOARD
FILTER PUMP RELAY
IN LOAD/POWER
CENTER
LINE SIDE:Source voltage
-120 VAC or 240 VAC to circuit breaker sub-panel
2-SPEED PUMP OPTION
TO AUX SOCKET
(FILTER PUMP)
ON CIRCUIT BOARD
TO AUX SOCKET
ON CIRCUIT BOARD
IntellilChlor
Communication Cable
Note: For more information about operating automation pool controllers, refer to the following manuals:
- IntelliTouch User’s Guide (P/N 521075)
- EasyTouch User’s Guide” (P/N 521044)
- SunTouch User’s Guide” (P/N 520785)
IntelliChem™ Installation and User’s Guide
2-SPD Pump
(wired for 120 or 240 VAC)
CONNECTING INTELLICHEM TO AN AUTOMATION CONTROL SYSTEM
Wiring IntelliChem AC Power to Filter Pump Relay
IntelliChem AC Power Wiring Instructions:
When using IntelliChem as a stand alone device (with a time clock) or with an IntelliChlor salt chlorine generator, IntelliChem MUST BE CONNECTED TO THE PUMP SIDE OF THE
MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for
IntelliChem AC power wiring diagram). This ensures that IntelliChem will only dispense chemicals when the filter pump is ON. Note:
For IntelliTouch®, EasyTouch® or SunTouch® automation control system using an IntelliFlo pump (or 2-speed pump) and an IntelliChlor (SCG), the IntelliChlor
AC power center wires must also be connected to the PUMP SIDE OF THE
MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for diagram). This ensures that IntelliChem and IntelliChlor only produce chlorine when the main filter pump is on.
To connect IntelliChem AC power wires to EasyTouch, IntelliTouch and SunTouch filter pump relay (see diagram on previous page).
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect AC power to EasyTouch, IntelliTouch and SunTouch load/ power center at the circuit breaker before servicing, or removing the HIGH
VOLTAGE FRONT PANEL. Failure to do so could result in death or serious injury to installer, service person, pool users, or others due to electrical shock.
1.
IntelliChem AC power: Run the IntelliChem AC power wires to the
EasyTouch, IntelliTouch or SunTouch enclosure.
2.
EasyTouch/IntelliTouch Load Center: Unlatch the enclosure door spring latch, and open the door.
3.
Discharge Electrostatic energy before removing the cover by first touching the metal part of the enclosure.
4.
Loosen the two (2) retaining screws from the HIGH VOLTAGE FRONT
PANEL. Remove the panel from the enclosure.
5.
Connect the IntelliChem AC power cord wires to the LOAD/PUMP SIDE of the main filter pump relay (see wiring diagram on page 40).
6.
When the connection is completed: EasyTouch/IntelliTouch: Close the control panel and secure it with the two (2) retaining screws. SunTouch:
Close the front control panel and secure with the retaining screw.
7.
Close the load center front door. Fasten the spring latch.
41
IntelliChem™ Installation and User’s Guide
42
CONNECT INTELLICHEM AC POWER
TO FILTER PUMP RELAY
Retaining screws
High Voltage
Front Panel
Route IntelliChem AC power into opening under enclosure
CONNECT INTELLICHEM AC POWER
TO FILTER PUMP RELAY
Load Center (with SCG option)
Power Center
(with SCG option)
IntelliChlor (SCG)
Transformer
IntelliChem™ Installation and User’s Guide
43
Connecting IntelliChem RS-485 Communication Cable to the Automation Control System Circuit Board
To connect IntelliChem COM Port Cable to EasyTouch, IntelliTouch and SunTouch
COM port (see diagram on page 40):
1.
IntelliChem RS-485 cable: Strip back the cable conductors ¼ in. Insert the wires into the connector screw terminals. Make sure to match the color coding of the wires; YELLOW = +DATA, GREEN = -DATA and
BLACK = GND. Secure the wires with the screws.
2.
Run an RS-485 cable from the IntelliChem enclosure to the EasyTouch,
IntelliTouch or SunTouch enclosure.
3.
Unlatch the load center/power center enclosure door spring latch, and open the door.
4.
WARNING! Switch AC power OFF to load/power center before installation (see note on page 41) EasyTouch/IntelliTouch Load
Center: Loosen the two (2) retaining screws from the control panel.
(a) Lower down the control panel on its hinges to access the motherboard located behind the control panel.
(b) Route the IntelliChem RS-485 cable up through the low voltage raceway in the load center to the motherboard.
SunTouch Power Center: Route the conductor cable up through the lower grommet opening into the enclosure.
5.
Strip back the IntelliChem cable conductors ¼ in. Insert the wires into the
COM port connector screw terminals on the circuit board: (EasyTouch
J20, IntelliTouch J7/8, SunTouch J11). Make sure to match the color coding of the wires; YELLOW = +DATA, GREEN = -DATA and BLACK =
GND. Secure the wires with the screws.
6.
When the connection is completed: EasyTouch/IntelliTouch: Close the control panel and secure it with the two (2) retaining screws. SunTouch:
Close the front control panel and secure with the retaining screw.
7.
Close the load center front door. Fasten the spring latch.
Setting Up IntelliChem with IntelliTouch, EasyTouch & SunTouch
IntelliTouch Automation Control System
The following describes how to setup IntelliChem from the IntelliTouch control panel.
From the IntelliTouch control panel you can adjust the pH and ORP set point values, view the IntelliChem status and monitor your pool water condition using the Saturation Index.
To access the IntelliChem screens, from the IntelliTouch Indoor Control Panel or the wireless MobileTouch® control panel:
Getting There
MENU SETUP EQUIPMENT INTELLICHEM
PH/ORP Values: The pH and ORP values are displayed next to the set point settings.
pH Set: Displays the current pH set point value. The adjustable range is from 7.2 to 7.6 in increments of 0.1. The default pH set point value is 7.5. To adjust the pH set point, press the button next to pH Set.
IntelliChem™ Installation and User’s Guide
44
ORP Set: Displays the current ORP set point value. The adjustable range is from 650 to 800 in increments of 10. The default ORP set point value is 700. The ORP set point is the value that
IntelliChem will try to achieve based on the active sanitizer. To adjust the ORP set point, press the button next to ORP Set.
STATUS: Displays the current communication link between IntelliTouch and IntelliChem via the RS-
485 cable. IChem Comm Error: Check the RS-
485 communication cable is connected to the
COM port on the IntelliTouch Personality circuit board.
PH 6.95 PH SET 7.5
ORP 675
USING SCG
ORP SET 700
STATUS: ICHEM COMLINK NORMAL
STAURATION INDEX/MENU +0.5
MENU/SETUP/EQUIPT/INTELLICHEM
BACK
DISABLE
ICHEM EXIT
USING SCG: “USING SCG” displays if the
IntelliChlor salt chlorine generator is enabled. The
SCG is enabled and disabled from the MENU >
SETUP > EQUIPMENT > CHLORINATOR screen.
Note: IntelliChem must also be set up to use the
IntelliChlor SCG either with the AUTO SETUP
Setup Wizard (page 6) or the Configuration/
Hardware/ORP Control/Doser Type (page 23).
SATURATION INDEX:
WATER CONDITION:
TEMPERATURE: 84˚F
0
GOOD
TDS: 80ppm
- CALCIUM HARDNESS 400 ppm +
- CYANURIC ACID 80 ppm +
- TOTAL ALKALINITY 120 ppm +
MENU/SETUP/EQUIPT/ICHEM/SATUR
DISABLE/ENABLE INTELLICHEM: To disable
IntelliChem, press the button under DISABLE
ICHEM. To enable IntelliChem, press the button next to INTELLICHEM. On the next screen press button next to NO and select YES. Press SAVE to save the setting and return to the Equipment screen.
Saturation Index/Menu: To access the
Saturation Index screen, press the button next to
SATURATION INDEX/MENU. The current
Saturation Index value, water condition, water temperature and Total Dissolved Solids (TDS) are displayed. Press the button next the following selections to adjust the levels/values:
Calcium Hardness: Recommended range is
200-400 ppm. Levels should be tested weekly.
Cyanuric Acid: Stabilizes chlorine in water from
BACK
PH 6.95 PH SET 7.5
ORP 675
USING SCG
ORP SET 700
STATUS: ICHEM COMLINK NORMAL
STAURATION INDEX/MENU +0.5
MENU/SETUP/EQUIPT/INTELLICHEM
BACK DOWN UP
UV degradation. When using the IntelliChlor
SCG, cyanuric acid level should be maintained between 30-50 ppm. Total Alkalinity: APSP’s recommended ideal range for is 80 to 120 ppm for “gunite” and concrete pools and 125-170 ppm for painted, vinyl, and fiberglass pools. Test levels weekly and adjust according to your pool professional’s recommendations.
Saturation Index: The saturation Index displays IDEAL (Optimum levels), CORROSIVE or SCALING. The following are recommended pool chemistry Saturation Index levels: pH
range: 7.2 to 7.6 ORP range: 650 to 800. Alkanlinity: 80 to 120 ppm. Calcium
Hardness: 200 - 500 ppm. Cyanuric Acid/Stabilizer: 30-50 ppm.
Note: See page 27 for information the online Langelier Saturation Index (LSI) Calculator to diagnose the water balance in your pool.
IntelliChem™ Installation and User’s Guide
45
Setting Up IntelliChem with EasyTouch Control System
EasyTouch Automation Control System
The following describes how to setup IntelliChem from the EasyTouch control panel.
From the EasyTouch control panel you can adjust the pH and ORP set point values, view the IntelliChem status and monitor your pool water condition using the Saturation Index.
To access the IntelliChem screens, from the EasyTouch Indoor Control Panel or the
EasyTouch wireless control panel: Press MENU > SETTINGS > INTELLICHEM
Clock
IntelliFlo
IntelliChlor
IntelliChem
IntelliChem
PH/ORP Values
Status
Sat Index pH pH
VAL 7.0
SET: 7.5
ORP VAL: 650
ORP SET: 750
IntelliChem
PH/ORP Values
Status
Sat Index pH Lvl:
ORP Lvl: SCG
IntelliChem: ON
ORP Dosage Limit
IntelliChem
PH/ORP Values
Status
Sat Index pH: 7.5 TMP: 91
CH: 250 TDS: 4250
TA: 100 CYA: 30
SI= +0.04 IDEAL
PH/ORP Values: Press the Right button to access the pH and ORP set point values screen. The pH and ORP sensor reading VALues are shown only if adequate flow is sensed by the flow switch and the delay has been satisfied. otherwise displays NA (not available) Use the
Up/Down button to adjust the pH set point value. Press the Right button again to set the ORP set point value.
Press MENU to save and return to the previous screen.
pH Set Point: Displays the current pH set point value.
The adjustable range is from 7.2 to 7.6 in increments of
0.1. The default pH set point value is 7.5.
ORP Set Point: Displays the current ORP set point value.
Use the Up/Down button to adjust the ORP set point value. The adjustable range is from 650 to 800 in increments of 10. The default ORP set point value is 700
The ORP set point is the value that IntelliChem will try to achieve.
STATUS: Displays the current communication link between EasyTouch and IntelliChem via the RS-485 cable. IChem Comm Error: Check the RS-485 communication cable is connected to the COM port on the EasyTouch circuit board. Other alarm messages are shown on page 48
Level Gauge indicator: Press the Up/Down button to
“fill” the gauge icon so that it visually represents the same amount of acid available in the container. Press
Up/Down button six (6) times to fill the gauge (three times to half fill the gauge). Six horizontal bars represent chlorine (or bromine) supply is full. One bar indicates the supply is nearly empty. Press MENU twice to exit and update the values.
Note: IntelliChem must also be set up to use the IntelliChlor SCG either with the AUTO
SETUP Wizard (page 6) or the Configuration/Hardware/ORP Control/Doser Type (page 23).
Sat Index: To access the Sat Index settings, press the Up/Down button then press the
Right button. Use the Up/Down button to adjust the levels/values for: CH (calcium
hardness), TDS (Total Dissolved Solids), TA (total alkalinity), CYA (cyanuric acid) and
TMP (current temperature).
Note: See table below for ideal Saturation Index levels.
SI: The saturation Index is displayed. IDEAL: Optimum levels. CORROSIVE or SCALING:
Press the Menu button twicw to exit and update the values. Return to this menu for updated SI calculations. screen. Note: See page 24 for information the online Langelier
Saturation Index (LSI) Calculator to diagnose the water balance in your pool.
IntelliChem™ Installation and User’s Guide
46
Setting up IntelliChem with SunTouch Control System
SunTouch Automation Control System
The following describes how to view the current IntelliChem pH and ORP levels from the
SunTouch control panel. To access the IntelliChem screens Press MENU >
DIAGNOSTICS > INTELLICHEM
IntelliChem pH: 7.65 ORP:832
Displays the current pH and ORP levels. IntelliChem is connected to the SunTouch control system via the
RS-485 cable. The RS-485 communication cable is connected to the COM port on the SunTouch circuit board.
TROUBLESHOOTING
General Troubleshooting Guide (also see Help Guide on page 47)
1.
Run Meter Self-Test (see Configuration menu)
2.
Run Probe-Open Test (see Configuration menu)
3.
Clear pH and ORP Tweaks (see Configuration menu)
4.
Clean Sensors (see Maintenance section)
5.
Check chemicals and feed system
6.
Take sample of pool water for analysis of CYA, alkalinity, check saturation index, Balance water
7.
Replace Sensors
8.
Repeat above steps
General Guidelines
-
pH or ORP not able to reach setpoint
This may be a common issue that can easily be resolved by increasing the amount of chemical dispensed each day. If the pH Sensitivity is set to "Low" (the default),
IntelliChem will only administer the full dose at 0.5 from setpoint. If it seems to be stuck
0.3 from setpoint, you're only getting 3/5 of the programmed dose. Change the Sensitivity to "High" and you'll get the full dose at 0.2 pH or greater from setpoint. Or, turn pH
Sensitivity OFF - only turn it on if you're overshooting the setpoint.
Increasing the dose would essentially do the same thing. Increase the dosage as well as the dose-limit and reduce the mix time so you still get all 8 doses in the filter run time.
Diagnostics Self Test and Error codes
The overall functionality of the IntelliChem can be verified by running the self test.
Access this feature in the Configuration/Diagnostic menu. The test verify the LCD display, front panel LED indicators, push buttons, flow switch input, doser motors, relays, the RS-485 communication, and the meter.
Warning! This test will turn on the doser, so be sure that the tubing is installed in a safe manner so that the chemicals will be safely contained.
Error Codes
0x01 : LCD
0x02 : Backlight
0x04 : LEDs
0x08 : Buttons
0x10 : Flow Switch
0x20 : Outputs
0x40 : Loopback 485
0x80 : Meter
IntelliChem™ Installation and User’s Guide
Help Guide
S e q u e n c e
M e t e r T e s t
A c c e s s
M e n u / C o n f i g u r a t i o n / D i a g n o s t i c s
R u n M e t e r T e s t
A c t i o n
U t e s e s t t h c i r i s c u t e i t s t
H , t o t h v e r i f y t h a t t h e e n t e s t p H c i r c u i t L .
I t a t n h d e n
O r
R u
P c i r c u
T h e i t r y t e s t a n d f i r s t m e t e r s s h o w s a d i r e a g o p e r a t i n g n o s t i c p u n c a r il o p e r b r a t l y .
e d n s s e n s i n g v a l u e s f o r t h e A u t o
C a il n e il b r a t i o n s h o w s a n d
* * * s h o w
P A S S s
* * t w o
* t h e v a l u e s m e t e r f o r e a n d a c s e h .
n s
I f i n t g h e c i r b o c u t t o m i t r y i s g o o d .
I f t h e t e s t f a li s f a c t o r y t o d e t e r m i n e
, t h e s e w h i c h v a l u e s c a n p a r t o f t h e b e u s e d a t t h e c i r c u i t i s f a u l t y .
P
C
C
C
C
S
B
R r l l a a o e e h h e l t b a a e e a p
I e r n c n n e k m a i
T
T d c e w
P c t a e e r
D l s t e a o b o x s
W k s e s s e a t r s e r
R e p l a c e P r o b e s
M e n u / C o n f i g u r a
R
M u n
M e n e n
M u / e
O t e u / p H
R r
M
P
A t f l o w c e ll
T e e s n t u / t i o n / D i a g n o s t i c s p
M e n u
H
/ O
T w e a k
R P T w e a k
T h i s i s a 3 0 s e c o n d t e s t t h a t e v a l u a t e s t h e i n p u t s t o t h e p H t h e a n d p r o b
O R P e s m a r e e f u t e n r s .
c t i
T o n h e r i n g .
e s
I t u l t s w i ll a r e u s e d a c c u r a t e l t o y d d e t e r m i n e e t e c t i f a i f p r o b e i s d i s c o n n e c t e d o r h a s b r o k e n o r s h o r t e d w i r e s .
I t w i c r a c ll k n o t e d , b e e t c ; a b l e s o i t t o i s a s s e s s n o t n e i f c e t h e s s a r p r o b e s li y a n i n a r e d i c a d i r t y t i o n
, o l d t h a t
, t h e r p r o b e s e p l a c e m a y n o t h a v e t h e p r o b e w i t h o t h e r a n e p w r o b o r l e m s .
k n o
I f p r o b l e m s p e r s i s t , w n g o o d p r o b e .
S t h e e t t w m e a e t k : e r t o s h
0 .
O f t e n o u l d p t r h o e b l e w m a t s e r w i t h a r e t h e r e s u l t o f o f f
“ m s e t i s c a a n d il b r a t h e t e f d i n
” a p l r r o b e e a d s .
i n
T h i s g .
s c r
U n d e r e i e n d e s a l h o c i w s r c u t h e m s t a u s e r ’ s n c e s r e a d c o r r a p o o l e c t l y w i t h o u t a n y t w e a k a d j u s t m e n t .
S e e c l e a n i n g i n s t r u c t i o n s .
S e e p a g e 5 1 a n d 5 2 .
p H S
O R P e t t
S i n g s e t t i n g b s u t b t o n / u t t o
O v e r r i d e n / O v e r r i d e
S e l e c t d o s e r
[ D o s s e l e c e t i
] o t o n t i s u r n s p e o n c i t h e f i e d a i n p t p r h e o p r i a t e d
C o n f i g d o s e r .
u r a t i o n /
T h e
H a r
V e r i d w a r f y t h c o r r e c t l y .
e / e p H C o n t r o l p u m p i s r a o t a n d t i n g
/ O R P p r o p
C o e r l y n t r o a n d l t m e n u s .
u b i n g i s i n s t a ll e d
C h e c k p r o p e r d i r e c t i o n o f f l o w .
P u m p s a r e l a b e l e d w i t a n d f r o n t
O o
U f
T t h a e n
I d n t t u e l r n il C c l h e o c k w m , t h i s e e .
o t
O n e h e r o i s u t l e t t o w a i s r d t o w a r d t h e w a t h ll .
e h I N
V e r i f y p i c k u p t u b e c o n t a i n e r .
O n c e v i e r s a ll i f i e d , t h e w a y l e t t h e t o p u t h m e p s b o t t r u n o m o f o r a f t h e w h li e t o p r i m e t
W A R N h e
I N G t u b i n g
!
U s e u s e x t i n g r e t h e m e
D o s e c a u t i o n
O v e r r w h e n i d e h a f e a t u r e .
n d il n g p o o l c h e m i c a l s .
V e r i f y t h e t u b i n g i s n o t c l o g g e d , k i n k e d o r p u n c t u r e d .
S u p p il e s f o r t h e d o s e r p u m p
S e t h e t l e v e l s i n p H / O R P p H / O R P
S u p p il e s
S e t t i n g s
M e n u .
b u t t o n o r i n
V e r i f y c h e m i c a l s a r e f r e s h a n d o f t h e p r o p e r c o n c e n a m a t t e t r a t r o f i o n .
m o
M u r i a t i c n t h s o r a c i d l e s s a n d C h l o d e p e n d i n g r i n e o n d e g r s u n il a d g e h t s w i t h i n a n d t e m p e r a t u r e .
B e o f s u r e t h e c h e m i c a l .
s u p p l y c o n t a i n e r s c o n t a i n s u f f i c i e n t a m o u n t s
S e t t h e t a n k .
O
S u p p n c e t h il e e s l e v i n d i c e l a t t o c o r r e s p o n d o r g e t s t o t o t h e l e v e l t h e “ 0 ” l e v e l , t h e i n t h e a l a r m w i ll b e s e t
M a i n m e n u , S a t I n d e x T h e L a n g e il e r S a t u r a t i o n I n d e x i s a n i n d i c a t i o n o f t h e o v e r a ll w a t e r t e m p e r a t u r e , c o n d i t i o n p H , s a l t ,
.
I t s c a l c u c a l c i u m l a t i o n h a r d n e i s b a s e d s s , o n a n d t o t a l w a t e r a l k a f a c t o il n r ) .
i t y ( t o
T h e w h i c h r e s u l t s c y a n u r i c o f t h i s c a a l c i d h a s c u l a t i o n a a c r e o n u t r i b u t i n g s e d t o d e t e r m i n e i f t h e w a t e r i s c o r r o s i v e o r s c a il n g .
B a l a n c e d w a t e r a f f e c t s a t ll o h w e s a b t i h e il t y p o o f o t l h c e h e m i c a l s s a n i t i z e r t o t o f u n c t i o n d o i t s j o p b .
r o
I f p e r y o l y u ’ a r e n d h a v i n g p r o b l e m s w i t h m a i n t a i s a n p r o i t i z e f e s s r , i o c h e c k n a ll y a t h n a i s l y o r h z e d .
a v e a n i n g w a t w a t e r e r s a c l a r m p l e i t y o r
B a a n l d a n c e c a r e w a t e r o f t h e i s t h e f li t r r a t i o e s n u l t o f p r o p e r c h e m i c a l t r e a t m e n t
I f t h t h e e p p r o o o l b e s h a v e o p e r a t i n g b e e n p r o p e c l e a n e d r l y .
T r y a a n d n e w a s ll e o t h e r t o f p a r o s p e c b e s .
t s o f
A f t r e p e e r a p e r f o r m i n g t a ll t h e s e a ll t h e s e s t e p s s t e p s i t m a y p r o v e h e l p f u l t o
47
IntelliChem™ Installation and User’s Guide
48
Alarm Messages and Troubleshooting Tips
The IntelliChem is continually monitoring its own condition and that of the water chemistry. The following is a list of alarms and most likely causes. This should give you a good starting place for troubleshooting and resolving the alarm.
Troubleshooting the alarm messages
IntelliChem Message**
SI Scaling / SI Corrosive
EasyTouch/IntelliTouch,
Screen Logic
SI Scaling
SI Corrosive
Troubleshooting Tips
UOC Comm Err
Auto Calibration …Failed
Invalid EE CRC or Rev#
IChlr Com Er pH/ORP Invald Setup pH/ORP Dose Limit pH >7.8 Lockout pH/ORP Check Probe
Comlink Lost
Communication Lost
Auto Cal Failed
Calibration Failed
Memory Error
IChlr Comm Error
IntelliChlor- Communication Error
Invalid Setting
Invalid Hardware Config pH Dosage Limit
ORP Dosage Limit pH Feed at Limit
ORP Feed at Limit
PH Lock Out
Sanitizer Feed Locked
Check Probe(s)
Probe Check Fail
Water conditions indicate water has exceeded the threshold level. Refer to
Langelier Saturation Index water balance information and the user settings in the
Configuration/Preferences 2/2 page
Connection between IntelliChem and the automation controller. Check RS-
485 4-wire connection, terminals, and cables.
Check that the printed circuit board is clean and dry. Dirt, condensation or water leaking into the enclosure will cause faulty readings.
Turn unit off and on again. If problem persists reload firmware or replace circuit board.
The IntelliChlor SCG device may not communicate if the water is too cold, not circulating, salt level is too low. It may also take from 2 to 10 minutes or more to begin communication.
Sometimes this can be solved by cycling power to the IntelliChlor unit and waiting again. Check cable wires and terminals for proper connection.
This indicates incompatible settings in the pH setup. Check that the hardware configuration on pH Control page 1/2 and 2/2 correspond properly. That if you specify an internal pump, you’ve chosen one of the MTR_L/R devices, and if you’ve chosen an External doser, you’ve selected an external relay. Be sure you’re not using the same output device for both pH and
ORP or an alarm output. Check dosage, and supply settings. Check that if you are dosing by volume that you have provided the GPD of the doser.
If you are unable to resolve the problem, re-run the Auto Setup Wizard.
When it prompts to use previous values be sure to choose Reset All.
This alarm will be the normal course of water chemistry control when experiencing a heavier than expected bather load, high temperature, or improperly balanced water. First check the saturation index and balance the water chemistry. Increase the dosage and filter time, increase the daily limit.
During peak loads it may be easiest to administer chemicals by hand. The
Limit can be manually cleared in the pH/ORP Settings menu, accessed by the appropriate button to the left side of the LCD display. It can also be programmed to clear automatically each time the IntelliChem powers on, or at every 24 hours of continuous run time in the pH/ORP Dosage 2/2 menu.
This is a safety feature that prevents over feeding sanitizer if the pH gets too high. As pH increases, the sanitizer becomes less effective. The proper thing to do is first reduce the pH and then see if you really need to add more sanitizer. Often bringing down the pH is sufficient to free more sanitizer which
The Open Probes Test is available in the Configuration/Diagnostics menu.
Refer to trouble shooting guide for more details. The
Configuration/Preferences menu allows you to turn on continuous probe checking. This tests the probes each time before dispensing any chemicals.
This will help ensure that the measurements used to determine the dose were not a result of invalid measurements.
** Displayed in various places on the main screen
IntelliChem™ Installation and User’s Guide
49
Troubleshooting the alarm messages
IntelliChem Message**
SI Scaling / SI Corrosive
UOC Comm Err
Auto Calibration …Failed
Invalid EE CRC or Rev#
IChlr Com Er pH/ORP Invald Setup pH/ORP Dose Limit pH >7.8 Lockout pH/ORP Check Probe
EasyTouch/IntelliTouch,
Screen Logic
SI Scaling
SI Corrosive
Comlink Lost
Communication Lost
Auto Cal Failed
Calibration Failed
Memory Error
IChlr Comm Error
IntelliChlor- Communication Error
Invalid Setting
Invalid Hardware Config pH Dosage Limit
ORP Dosage Limit pH Feed at Limit
ORP Feed at Limit
PH Lock Out
Sanitizer Feed Locked
Check Probe(s)
Probe Check Fail
** Displayed in various places on the main screen
Troubleshooting Tips
Water conditions indicate water has exceeded the threshold level. Refer to
Langelier Saturation Index water balance information and the user settings in the
Configuration/Preferences 2/2 page
Connection between IntelliChem and the automation controller. Check RS-
485 4-wire connection, terminals, and cables.
Check that the printed circuit board is clean and dry. Dirt, condensation or water leaking into the enclosure will cause faulty readings.
Turn unit off and on again. If problem persists reload firmware or replace circuit board.
The IntelliChlor SCG device may not communicate if the water is too cold, not circulating, salt level is too low. It may also take from 2 to 10 minutes or more to begin communication.
Sometimes this can be solved by cycling power to the IntelliChlor unit and waiting again. Check cable wires and terminals for proper connection.
This indicates incompatible settings in the pH setup. Check that the hardware configuration on pH Control page 1/2 and 2/2 correspond properly. That if you specify an internal pump, you’ve chosen one of the MTR_L/R devices, and if you’ve chosen an External doser, you’ve selected an external relay. Be sure you’re not using the same output device for both pH and
ORP or an alarm output. Check dosage, and supply settings. Check that if you are dosing by volume that you have provided the GPD of the doser.
If you are unable to resolve the problem, re-run the Auto Setup Wizard.
When it prompts to use previous values be sure to choose Reset All.
This alarm will be the normal course of water chemistry control when experiencing a heavier than expected bather load, high temperature, or improperly balanced water. First check the saturation index and balance the water chemistry. Increase the dosage and filter time, increase the daily limit.
During peak loads it may be easiest to administer chemicals by hand. The
Limit can be manually cleared in the pH/ORP Settings menu, accessed by the appropriate button to the left side of the LCD display. It can also be programmed to clear automatically each time the IntelliChem powers on, or at every 24 hours of continuous run time in the pH/ORP Dosage 2/2 menu.
This is a safety feature that prevents over feeding sanitizer if the pH gets too high. As pH increases, the sanitizer becomes less effective. The proper thing to do is first reduce the pH and then see if you really need to add more sanitizer. Often bringing down the pH is sufficient to free more sanitizer which
The Open Probes Test is available in the Configuration/Diagnostics menu.
Refer to trouble shooting guide for more details. The
Configuration/Preferences menu allows you to turn on continuous probe checking. This tests the probes each time before dispensing any chemicals.
This will help ensure that the measurements used to determine the dose were not a result of invalid measurements.
IntelliChem™ Installation and User’s Guide
50
Cross Reference
IntelliChem™ Installation and User’s Guide
Tweaking pH
(Calibrating)
Measure the pH using a standard test kit by taking several readings and averaging the results. To Tweak the pH sensor see page 12.
Tweaking ORP
(Calibrating)
51
Always make sure the pH is at the set point before calibrating ORP.
Always control at PPM levels greater than 1.0 PPM when using
ORP sensors.
IMPORTANT: For best results the ORP should be at the ORP set point when calibrating. For best results the PPM should be at the desired level when calibrating
ORP.
To Tweak the ORP sensor see page 15.
IntelliChem Specifications
RATINGS:
Input Voltage:
Relay Rating:
Temperature:
Sensor Range:
120 VAC / 240 VAC 50/60 Hz
200 mA / 100 mA or 0.2 A / 0.1 A
Dry Contact 5 A, 120 VAC / 30 VDC
Min./Max. Operating Temperature 30° - 110° F pH 4.0 - 9.99 - ORP 0 - 999mV
Flow Open or Closed
MAINTENANCE
Winterizing: The Flow Cell sensors must be protected from freezing conditions. If the pool is winterized, plan to remove and store the sensors (as described above) as part of the normal pool winterizing process. The Flow Cell and related plumbing must be drained as well.
Water Chemistry
Always test water chemistry with a quality manual test kit. Therefore, it may be preferable to calibrate pH using commercially available reference solutions. If required, use the
IntelliChem Tweak pH feature to periodically adjust the pH reading (see above and page
12). It's important to note that changes in pH, cyanuric acid concentration, total dissolved solids, and use of additional or alternative sanitizers will all affect the primary sanitizer residual level relative to ORP. Maintain total alkalinity on regular basis to ensure pH stability. To maintain a consistent sanitizer residual in parts per million (ppm), periodically adjust the ORP level.
Sensor Maintenance: The Flow Cell sensors must be clean and free from oil, chemical deposits and contamination to function properly. After saturation in pool or spa water, the sensors may need to be cleaned on a weekly or monthly basis depending on bather load and other pool specific characteristics. Slow response, increased need to calibrate pH, and inconsistent readings are indications that the probes are in need of cleaning.
IntelliChem™ Installation and User’s Guide
52
MAINTENANCE
(Continued)
Cleaning the Flow Cell Sensors: To clean the ORP and pH sensors, turn off the AC source power to IntelliChem at the GFCI switch. Disconnect the probe connectors from the Flow Cell, unscrew the probe and carefully remove them from the Flow Cell. Clean the reference junction (the white ring at the bottom of the probe body) with a soft toothbrush. A household liquid dish washing detergent may also be used to remove any oil. Rinse with fresh water and reinstall probes. If properly cleaned probes continue to provide unstable readings or require excessive calibration, the probes should be replaced. Probe exposed to atmospheric conditions will cause the probe tips to dry out.
Store the sensors with the included plastic sensors storage caps if removed from the
Flow Cell for more than one hour. If the storage caps have been misplaced, store the probes individually in small glass or plastic containers with clean water covering the sensor tips. Store sensors in a location that will not be subjected to freezing temperatures.
Sensor Care
Contamination of the sensing elements often results in slow response and inaccurate readings. Clean the elements by the following procedures:
pH and ORP Sensors
1. Wash electrode tip in a liquid detergent and water. Carefully use a soft bristled toothbrush to wash the electrode tip and white sensing ring.
2.
Rinse after cleaning. To reinstall the flow cell (see page 33). Hand tighten to sensors to secure in place.
3.
Make sure the O-ring is installed on sensor.
4.
If the cable is longer than needed, it should be coiled neatly and attached under the enclosure.
pH Sensors Only
5.
Attempt to clean the sensor with liquid detergent first.
6.
If this is not successful, swirl the tip of the sensor in a 5 parts water and 1 part muriatic acid solution for 10 - 20 seconds.
7.
Rinse again and reinstall.
WARNING Do not rub hard the glass element in the sensor or use sand paper or other polishing material to clean. HANDLE ELECTRODE CAREFULLY Sensors contain external and internal glass elements. Do not drop or otherwise subject the sensor to vibration, physical impact, or freezing conditions. ANY TYPE OF BREAKAGE IS
NOT COVERED UNDER WARRANTY.
pH and ORP Sensors: pH electrodes sense the acidity of the water and work with any acid or base. The blue bands on the cables identify the pH sensors. The red bands on the cables identify ORP sensors. Each sensor is also identified on the sensor body. ORP electrodes are used to monitor the Oxidation Reduction Potential
(ORP is sanitization quality of the water) of a given solution. The sensing element of the ORP electrode is made of a precious metal such as platinum or gold.
Sensors: IntelliChem measures the following sensor measurements with the listed characteristics:
pH Range:
ORP Range:
4.00 to 9.99
0 to 999 mV
Flow Switch: This input measures if a switch is open or closed. Open is no water flow.
A closed switch indicates flow.
IntelliChem™ Installation and User’s Guide
Motor Pump Head Tube Yearly Replacement
For best results, it is recommended to replace the IntelliChem motor(s) pump head tube(s) (P/N 521384Z) once a year.
53
Pump Head Tube(s) Replacement (for single or multiple pumps):
Disconnect AC power to IntelliChem enclosure at the circuit breaker before servicing. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
1.
STOP the main pool filter pump.
2.
First loosen the Jaco fitting on the OUTLET tube. Carefully disconnect the tube. Keep the tube pointed upward to keep the chemical from spilling out the top of the tube.
3.
Connect the tube to the OUTLET of the new pump head Jaco fitting.
Secure the tube.
4.
Repeat Step 1 and 2 for the INLET tube.
5.
Remove the upper and lower screws securing the old pump head and remove the pump head from the motor assembly.
6.
Install the new pump head (with attached tubes) to the motor assembly.
Secure the pump head with the two screws.
Screws
Pump head (P/N 521348Z)
(with tube, Jaco fitting and screws)
Output tube
(Jaco fitting)
Inlet tube
(Jaco fitting)
IntelliChem™ Installation and User’s Guide
54
IntelliChem Replacement Parts List
1.
P/N 521465Z - Top Half (Lid with
overlay and wiring diagram).
2. P/N 521319Z - IntelliChem Circuit
Board.
3. P/N 8520031Z - Circuit Breaker.
4. P/N 521348Z - Pump head with
tube, Jaco fittings and screws.
5. P/N 521466Z - Jaco fitting.
6. P/N 521467Z - Enclosure mounting
brackets.
7. P/N 521338Z - Pump motor.
8. P/N 521468Z - Strain relief kit.
9. P/N 521335Z - Replacement
transformer with mounting plate.
9
4
8
Waranty Information:
The IntelliChem controller has a one year limited warranty. For more information contact Customer
Support (800) 831-7133
IntelliChem™ Installation and User’s Guide
5
7
6
1
3
2
IntelliChem Flow Cell Replacement Parts List
1. P/N 744000260 - Sensor, pH
2. P/N 744000390 - Sensor, ORP
3. P/N 754000310 - Flow Cell with Flow Switch Sensors
6
4. P/N 521342Z - IntelliChem Parts Bag (not shown)
5. P/N 754000440 - Flow Switch Sensor
6. P/N 744000280 - Cable, pH 10 ft
7. P/N 744000350 - Cable, ORP 10 ft
1
23
5
7
2
55
3
Waranty Information:
The IntelliChem pH sensor and ORP sensor, each have a two year limited warranty. For more information contact Customer
Support (800) 831-7133
IntelliChem™ Installation and User’s Guide
56