advertisement
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
FOR SERVICE INFORMATION
U.S. AND CANADA CALL: 1-800-807-9054
24 HOURS/DAY 7 DAYS/WEEK
TABLE OF CONTENTS
UNCRATING AND INSPECTION PAGE 1
ASSEMBLY AND INSTALLATION
POWER SAVER SWITCH
SECURITY FEATURES
CLEANING PROCEDURES
PAGE 1
PAGE 2
PAGE 2A
PAGE
PAGE 4
TROUBLESHOOTING GUIDE
MAINTENANCE PROCEDURES
PAGE 5, 6
PAGE 7, 8, 9
PARTS LIST/EXPLODED VIEW PAGE 10, 11, 12, 13
DRAWINGS
CRUMB TRAY
LOAD AND UNLOAD TRAYS
ADJ. HEAT SHIELD, FRONT VIEW
COMPONENT ARRANGEMENT
HEATER TUBE INSTALLATION
DRIVE SYSTEM
WIRING DIAGRAMS [T710(H,TW)]
PAGE 1
PAGE 1
PAGE 3
PAGE 6
PAGE 7
PAGE 9
PAGE 15, 16
WIRING DIAGRAMS [T714(H,TW)]
WIRING DIAGRAMS [B710(H)]
PAGE 16, 17
PAGE 18
WIRING DIAGRAMS [S710(H), Jamba Juice] PAGE 19
WIRING DIAGRAMS [S714(H)] PAGE 20
REV. 12/6/2005 RMS
HG0102
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
UNCRATING AND INSPECTION
Unpack unit and components from container. Remove all visible packing material, inspect unit for damage. If damage is discovered, file a claim immediately with the carrier that handled the shipment.
ASSEMBLY AND INSTALLATION
A. Attach legs by screwing into weld nuts, as shown below.
Page 1
ADJUSTABLE LEG: SCREWS INTO WELD NUT LOCATED
AT EACH CORNER ON BOTTOM SIDE OF TOASTER
LEVELING OF THE TOASTER CAN BE DONE BY TURNING
THE FOOT SECTION OF THE LEG COUNTER CLOCKWISE
B. Anti Skid pads are available at no charge and may be adhered to the foot section of each leg to prevent sliding. Call 1-800-225-3958 for details.
WARNING: the National Sanitation Foundation does not approve Use of these pads.
C. Place load and unload trays as shown below.
LOAD UP TRAY
CAUTION: DO NOT OPERATE UNIT WITHOUT
CRUMB TRAY PROPERLY POSITIONED
AS THIS WILL CAUSE OVERHEATING IN THE
CONTROL BOX.
HEAT REFLECTOR / CRUMB TRAY
TOAST CHUTE
(REAR DISCHARGE)
TOAST CHUTE
WARNING: MAKE SURE ALL INPUT POWER IS OFF BEFORE INSTALLING/REMOVING
ANY PARTS.
WARNING: BEFORE INSTALLING UNIT(S), CHECK WITH LOCAL POWER COMPANY TO
DETERMINE ACTUAL VOLTAGE AT JOB SITE. NEVER PLUG A 208-VOLT UNIT
INTO 240 VOLTS OR A 240 VOLT UNIT INTO 208 VOLTS.
WARNING: BE ABSOLUTELY SURE THE GROUND CONNECTION FOR THE RECEPTACLE
IS PROPERLY WIRED. NEVER CONNECT UNIT TO POWER WITHOUT
PROPER GROUND CONNECTIONS. IMPROPER GROUND MAY RESULT IN
SEVERE INJURY OR FATALITY.
REVISED 4-15-96 MJC
Page 2
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
OPERATION
Your Holman toaster may be equipped with a Power Saver Switch, details are as follow;
POWER SAVER
SWITCH
FULL
POWER
TOGGLE POWER SAVER
OFF
1/4 POWER
STAND BY
FULL POWER
OFF OFF
1/4 POWER
STAND BY
ROTARY POWER SAVER
Power Saver
Switch Positions
FULL POWER-
OFF-ROTARY:
OFF-TOGGLE:
STANDBY-
When in this position your unit is at Full Power and ready to use.
Adjust the Top and Bottom Variable Heat Controls and Conveyor
Belt Speed Control to your desired settings.
Two off positions are provided so that a single rotation to either direction will result in the unit being turned OFF.
The center position of the toggle switch turns the unit completely
OFF regardless of heat and speed control settings.
The standby position reduces the power to the unit to 1/4, and therefore saves 75% of the energy consumption. In this position your unit will stay warm and reduce the reheat time when switched to Full Power to 20 to 30 seconds.
REV. 1/28/97 MJC
FULL KEY LOCKING COVER
FITS OVER CONTROLS AND
SIDE PANELS TO PREVENT
TAMPERING
Fig. 1
SECURITY TOAST
CHUTE MOUNTING
ROD
S710CHUT.WMF
Fig. 2
COTTER PIN
S710LOK.WMK
HOLMAN
S710LEG.WMF
SECURITY COUNTER MOUNTING
BRACKET ATTACHES TO LEG FOOT
AND IS SECURED TO COUNTER
WITH A SCREW.
COTTER PIN
LEG SCREWS
INTO THE BOTTOM
OF TOASTER
KEY LOCK
Fig. 3
MOUNTING
BRACKET
FOOT SCREWS
INTO BOTTOM
OF LEG
Page 2A
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS S710(H), S714(H)
HOLMAN
SECURITY COVER :
Your Holman models S710 and S714 are quipped with a full front key locking cover (fig.1).
This over fits over the front and sides of the unit.
The security cover must be removed with a key in order to gain access to the controls, side panels, legs and toast chute to be removed.
To remove, unlock the cover using the key. Pull locked side of cover out and away from the unit.
The right side will release at the same time.
To replace the cover, Hook the right side of the cover over the latch on right front of the unit while sliding the left side of the cover over the lock. Secure cover using key.
TOAST CHUTE MOUNTING ROD
SLIDES THOUGH MOUNTING HOLE
IN CHASSIS AND THROUGH LOOP IN
TOP OF TOAST CHUTE
TOAST CHUTE ;
To install the toast chute (fig. 2), Remove the left side panel by removing two screws and pulling the top part of the panel out while lifting up.
Remove the mounting rod by sliding it through chassis.
Next, place the toast chute beneath toaster as shown. Line up the looped end of toast chute with holes in the rear of toaster as shown. Insert mounting rod through the holes in chassis and the toast chute (If legs have not been installed, do so now).
Reinstall side panel and secure with screws.
Toast chute is now ready for use.
LEGS :
To secure the toaster to the counter (fig.3),
Remove both side panels by removing two screws and pulling the top of the panel out while lifting up. Unscrew the foot of each leg and slide counter-mounting brackets onto the legs. Screw the foot back onto each leg and install legs onto the toaster. Place the small cotter pin through the holes in threaded portion of each leg.
Secure the mounting brackets to the counter with a screw or bolt. Reinstall both side panels and secure with screws.
NOTE: Security models are not supplied with a power saver switch.
REV. 1/28/97 MJC
PAGE 3
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
COOKING PROCEDURES
A. BREAD TOASTING
NOTE: Models TX710(H) and TX714(H) have an extended conveyor belt in lue of a load up tray. Place (do not press) the product on the extended conveyor belt for toasting or heating. Follow the instructions listed below for cooking and operation procedures.
1. On models T710H, TX710(H), T714H, TX714(H) and B710H, S710(H),
S714(H) lower the front heat shield all the way down, leave just enough clearance for bread slices to pass under the shield into the cooking cavity (See illustration below).
ADJUSTABLE HEAT SHUTTER
2. Turn top and bottom heat controls to HI; turn conveyor speed control to
50.
3. Allow warm up time of 5 to 10 minutes.
4. Test with a slice of bread. a. If toast is too light, turn conveyor speed control counterclockwise to a
slower b. If toast is too dark, turn conveyor speed control clockwise to a faster
speed.
B. MODELS T710(H), TX710H, T714(H), TX714H, S710(H), S714(H)-BUN TOASTING
1. Buns may be top or bottom toasted. Turn appropriate heat control to HI, set conveyor speed control to 50.
2. On models with high (3") clearance (T710H, TX710H, T714H, TX714H, S710H,
S714H), lower the front heat shield as far as possible, leave just enough clearance for the bun half to pass under and into the cooking cavity.
3. Test with a half of a bun. a. If bun half is too light, turn conveyor speed control counterclockwise
to b. If bun half is too dark, turn conveyor speed control clockwise to a
faster
Cooking procedures continued on page 4
REVISED 7/29/97 MJC
PAGE 4
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
COOKING PROCEDURES CONT.
C.
The model B710(H) has higher wattage tubes on the top than on the bottom, therefore when placing the bun halves on the conveyor you should place them cut side up.
D. DEEP TOASTING OR BAKING (Units with Variable Heat Controls).
Food products that require deep heating without exterior toasting may be heated by reducing the oven temperature (lowering the top and/or bottom heat controls) and cooking at slower speeds. Some foods may require more top heat than bottom heat or vice versa. Every product will require some experimentation to arrive at the correct balance of heat control and conveyor speed settings. Each time a setting is changed allow about 5 minutes for the unit to stabilize.
CLEANING PROCEDURES
1. Turn top and bottom heat controls to the OFF position.
2. For lightly soiled conveyor belts, turn conveyor speed control to fastest setting (100) and wipe with a damp cloth.
3. For heavily soiled conveyors, turn conveyor speed control to fastest setting
(100) and wipe with a light abrasive pad.
4. Turn conveyor speed control off.
5. After the unit cools, remove interior crumb tray (as shown below) and clean.
Slide crumb tray back into position. DO NOT OPERATE UNIT WITHOUT
CRUMB TRAY IN PLACE AS THIS CAUSES OVERHEATING IN THE
CONTROL BOX AND MAY ACTIVATE THE HEAT LIMIT SWITCH.
6. Wipe exterior surface of unit.
LUBRICATION OF DRIVE CHAIN WITH A GRAPHITE BASED LUBRICANT IS REQUIRED AS
PERIODIC MAINTENANCE. CALL HOLMAN FACTORY SERVICE DEPARTMENT FOR
DETAILS.
LOAD UP TRAY
CAUTION: DO NOT OPERATE UN
WITHOUT CRUMB TRAY AS
THIS CAUSES OVERHEATING IN
THE CONTROL BOX.
IDLER SHAFT
DRIVE SHAFT
CONVEYOR LINK, MODEL T710
HEAT REFLECTOR / CRUMB TRAY
TOAST CHUTE
CONVEYOR LINK, MODEL T714
CONVEYOR BELT
(TOP VIEW)
SHOWN WITHOUT TOP COVER
REVISED 12/23/96 MJC
PAGE 5
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
TROUBLESHOOTING GUIDE
A. UNIT WILL NOT HEAT, CONVEYOR WILL NOT TURN.
1. Be sure the main circuit breaker is switched to the ON position.
2. Check to see if the toaster is plugged in and all controls are turned to the
ON
B.
1. Check to see if both top and bottom heat controls have been turned to
HI.
2. Push heat limit switch on front of control box as shown below.
If this reactivates the heater tubes, see HEAT LIMIT SWITCH in
section
C. HEAT LIMIT SWITCH
Your Holman conveyor toaster is equipped with an automatically activated
Heat Limit Switch that interrupts the heater tube connections if the ambient temperature in the control box exceeds 190F (88C). This heat limit switch can be reset manually by pushing the red button on the front of the control box.
HEAT LIMIT SWITCH
CONVEYOR SPEED CONTROL
BOTTOM HEAT CONTROL
TOP HEAT CONTROL
THE HEAT LIMIT SWITCH IS ACTIVATED WHEN THERE IS NOT
SUFFICIENT AIR FLOW GENERATED BY THE COOLING FAN. WHEN
HEAT LIMIT SWITCH HAS BEEN ACTIVATED:
1. DISCONNECT UNIT FROM POWER SOURCE.
2. Check to see if air intake area in the bottom center of the control box cover is free of dust, grease or other obstructions.
Troubleshooting guide continued on page 6
REVISED 1/28/97 MJC
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
TROUBLESHOOTING GUIDE CONT.
PAGE 6
3. Check if crumb tray is in place. NEVER OPERATE UNIT WITHOUT
CRUMB TRAY IN PLACE AS THIS CAUSES OVERHEATING IN THE
CONTROL
4. If no obstructions to the airflow can be found and if the crumb tray is in place, call Holman Factory Service Department at 1-800-225-3958 for
assistance.
1. DISCONNECT UNIT FROM POWER SOURCE.
2. Remove right hand side panel (from operator's position). Loosen screws holding drive motor in place and slide motor toward the rear of unit.
Remove drive chain and manually move conveyor belt to check for mechanical binding. If conveyor moves freely, call Holman Factory
Service control may need replacement.
CONTROL KNOBS
SHAFT BEARINGS
RESET BUTTON
CONVEYOR
SPEED CONTROL
DRIVE SHAFT SPROCKET
DRIVE CHAIN
DRIVE MOTOR ADJUSTMENT SLOTS
HEAT CONTROLS
TERMINAL STRIP
RIGHT SIDE SHOWN WITHOUT SIDE PANEL
DRIVE MOTOR
1. Call Holman Factory Service Department at 1-800-225-3958 as speed control should be replaced.
REVISED 7/29/97 MJC
PAGE 7
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
MAINTENANCE PROCEDURES
A. REPLACING HEATER TUBES (as below)
1. DISCONNECT UNIT FROM POWER SOURCE.
2. Remove right and left side panels.
3. Remove heater tube wire from terminal block connection, keeping top and bottom wires separate.
4. Remove heater tube retainers by removing retaining screws with washer.
Gently, pull defective heater tube out of unit.
Gently, put new heater tube into unit.
7. Replace heater tube retainers, reconnect heater tube wires to terminal block and install side panels.
HEATER TUBE RETAINER
AIR INTAKE
HEATER TUBE TERMINAL BLOCK (4 POS.)
(2 POS. ON OPOSITE SIDE)
SIDE PANEL
HEATER TUBE RETAINER
HEATER TUBE
Maintenance procedures continued on page 8
REVISED 9/14/94 MJC
PAGE 8
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
MAINTENANCE PROCEDURES (CONT.)
B. REPLACING FAN MOTOR
1. DISCONNECT UNIT FROM POWER SOURCE.
2. Remove control box cover with fan motor.
3. Unplug power supply cord from fan motor.
4. Remove(4)screws that hold fan motor and grill to cover.
5. Put replacement motor and grill in place and secure to the control box
cover screws.
6. Reconnect power supply cord to fan motor.
7. Replace control box cover.
CONTROL BOX COVER
AIR INTAKE
FAN MOTOR
SECURED BY 4 SCREWS
AIR INTAKE SCOOP
Maintenance procedures continued on page 9
REVISED 9/14/94 MJC
PAGE 9
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
MAINTENANCE PROCEDURES (CONT.)
C. REPLACING BELT DRIVE MOTOR
1. DISCONNECT UNIT FROM POWER SOURCE.
2. Remove right side panel and control box covers.
3. Remove sprocket from motor shaft.
4. Remove the wire from terminal block connecting the drive motor to internal wiring. On units rated 208 or 240 volts, note which color leads are being used for these connections and which lead is capped with white tape. The new motor should use the same arrangement.
5. Remove screws holding motor in place.
6. Put new motor in place and attach loosely with mounting screws.
7. Replace sprocket on motor shaft.
8. Slide motor until the drive chain has about 1/8" slack when lightly pushed at the center of its top open run.
9. Tighten screws to secure motor.
10. Rewire leads same as removed in step 4.
11. Replace side panel and control box cover.
IF ASSISTANCE IS REQUIRED FOR THIS OR ANY OTHER PROCEDURE IN THIS
MANUAL CALL HOLMAN FACTORY SERVICE DEPARTMENT AT 1-800-225-3958, 24
HOURS/DAY 7 DAYS/WEEK.
DRIVE SPROCKET WITH SET SCREW
SHAFT BEARINGS
RIGHT SIDE SHOWN WITHOUT SIDE PANEL
DRIVE SHAFT SPROCKET
DRIVE CHAIN
DRIVE MOTOR ADJUSTMENT SLOTS
(BOTTOM VIEW)
DRIVE MOTOR
DRIVE MOTOR
MOUNTING SCREW
REVISED 9/19/94 MJC
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
PARTS LIST /EXPLODED VIEW MODEL T710(H), 120, 208, 240 VOLT
28.
3
..
4.
2.
5.
PAGE 10
27.
17.
16.
18.
11.
11.
9.
6.
21.
22.
19.
20.
13.
14.
12.
10.
8.
7.
24.
23.
15.
25.
26.
PART No. QTY
.
1). 400821
2). 197848
2a). 197841
2b). 197844
2c). 197842
3). 400833
4). 160000
5). 400827
5a). 400925
6). 401486
6a). 416789
7). 2P-200662
8). 200643
9). 200645
10). 100900
11). 112261
12). 200519
12a). 200509
13). 200558
DESCRIPTION PART No. QTY. DESCRIPTION
1
4
4
4
4
4
1
1
1
2
2
1
1
1
1
4 Bearings
1
1
Cover, Top
Heater Tube, 120 Volt
Heater Tube, 220 Volt
Retainer, Heater Tube
Conveyor Belt, T710(H)
Back Panel, Low
Back Panel, High
Side Panel, Low
Side Panel, High (H)
Drive Chain T710(H)
Drive Sprocket
Driven Sprocket
Drive Shaft
Drive Motor, 120 Volt
Drive Motor, 208/240 Volt
13a). 200560
14). 100311
1
1
Fan Motor, 208/240 Volt
Control Box Cover
200652 1 Fan
16). 100901 1 Idler Shaft
100541 1 Crumb
18). 200538 2 Infinite Switch, 208/240 Volt
18a). 200539 2 Infinite Switch, 120 Volt
19). 118000 1
19a). 118042
20). 200566
21). 200702
1
1
2
Speed Control, 120 Volt
Speed control, 208/240 Volt
Reset/High Limit
Knob, Infinite Switch
22). 200703
23). 200551
24). 200712
25). 140025
26). 400825
27). 200753
28). 400891
1
1
4
1
Knob, Speed Cont'l/ Power Saver
Power Saver Switch
Leg, 4" Plastic
Power Supply Cord
1 Toast
1
1
Load up Tray
Heat Shutter (H Model Only)
1 Fan Motor, 120 Volt *29). 115603 4 Security Leg , S710(H) (not shown)
Parts continued on page 11
REVISED 12/6/2005 RMS
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
PARTS LIST /EXPLODED VIEW MODEL TX710(H) 120, 208, 240 VOLT
1.
3 ..
28.
4.
2.
5.
PAGE 11
17.
16.
18.
29.
11.
9.
6.
21.
22.
19.
20.
13.
14.
12.
25.
10.
8.
7.
27.
23.
15.
24.
26.
PART No. QTY. DESCRIPTION
1). 400821
2). 197848
2a). 197841
2b). 197844
2c). 197842
3). 400833
4). 160003
5). 400827
5a). 400925
6). 401486
6a). 416789
7). 2P-200662
8). 200643
9). 200645
10). 100900
11). 112261
12). 200519
12a). 200509
13). 200558
1
4
4
4
4
4
1
1
1
2
2
1
1
1
1
2
1
1
1
Cover, Top
Heater Tube, 120 Volt
Heater Tube, 220 Volt
Retainer, Heater Tube
Conveyor Belt, T710(H)
Back Panel, Low
Back Panel, High
Side Panel, Low
Side Panel, High (H)
Drive Chain
Drive Sprocket
Driven Sprocket
Drive Shaft
Bearings, Rear
Drive Motor, 120 Volt
Drive Motor, 208/240 Volt 27). 401131
Fan Motor, 120 Volt
PART No. QTY. DESCRIPTION
13a). 200560
14). 100311
1
1
Fan Motor, 208/240 Volt
Control Box Cover
200652 1 Fan
16). 100901 1 Idler Shaft
100541 1 Crumb
18). 200538 2 Infinite Switch, 208/240 Volt
18a). 200539 2 Infinite Switch, 120 Volt
19). 118000
19a). 118042
20). 200566
21). 200702
22). 200703
1
1
1
2
1
Speed Control, 120 Volt
Speed control, 208/240 Volt
Reset/High Limit
Knob, Infinite Switch
Knob, Speed Cont'l/ Power Saver
23). 200551
24). 200712
25). 140025
25a). 140052
26). 400825
28). 400891
1
4
1
1
1
Power Saver Switch
Leg, 4" Plastic
Power Supply Cord, 208/240 Volt
Power Supply Cord, 120 Volt
Toast Chute
1 Extension
1 Heat Shutter (H Model Only)
Parts continued on page 12
29). 200693
REVISED 12/6/2005 RMS
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
PARTS LIST /EXPLODED VIEW MODEL T714(H)
28.
PAGE 12
3
..
4.
2.
5.
27.
17.
16.
18.
11.
11.
9.
6.
21.
22.
19.
20.
13.
14.
12.
10.
8.
7.
24.
23.
15.
25.
26.
1). 400847
2). 197850
2a). 197846
2b). 197851
3). 400833
4). 160002
5). 400853
5a). 400926
6). 401486
6a). 416789 1
7). 2P-200663 1
8). 200645
9). 200644
1
1
1
1
1
10). 100902
11). 112261
12). 200509
4
4
4
1
1
4
1
1
1
Top Cover 13). 200560
Heater Tube, 240 Volt 14). 100312
Heater Tube, 208 Volt 16). 100903
Retainer, Heater Tube 17). 100542
Conveyor Belt 18). 200538
Back Panel, Low
Back Panel, High
Side Panel, Low
19). 118042
20). 200566
21). 200702
Side Panel, High
Drive Chain
Drive Sprocket
Driven Sprocket
Bearings
Drive Motor
22). 200703
23). 200547
24). 200712
25). 140027
26). 400846
27). 200756
28). 400899
*29). 115603
Parts continued on page 13
2
1
4
4
1
1
1
1
1
1
4
1
1
1
1
1
2
DESCRIPTION
Fan Motor
Control Box Cover
Idler Shaft
Crumb Tray
Infinite Switch
Speed Control
Reset Switch
Knob, Infinite Switch
Knob, Speed control/Power Saver
Power Saver Switch
Leg, 4" Plastic
Cord/Plug Set
Heat Shutter (H model only)
Security Leg, S714(H) (not shown)
REVISED 12/6/2005 RMS
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
PARTS LIST /EXPLODED VIEW MODEL TX714(H)
1.
PAGE 13
3
..
28.
4.
2.
5.
17.
16.
18.
29.
11.
9.
6.
21.
22.
19.
20.
13.
14.
12.
25.
10.
8.
7.
27.
23.
15.
24.
26.
1). 400847
2). 197850
2a). 197846
2b). 197851
3). 400833
4). 160004
5). 400853
5a). 400926
6). 401486
6a). 416789 1
7). 2P-200663 1
8). 200645
9). 200644
1
1
10). 100902
11). 112261
1
1
1
12). 200509
1
1
1
4
4
4
1
1
4
Top Cover 13). 200560
Heater Tube, 240 Volt 14). 100312
Heater Tube, 208 Volt 16). 100905
Retainer, Heater Tube 17). 100508
Conveyor Belt 18). 200538
Back Panel, Low
Back Panel, High
Side Panel, Low
19). 118042
20). 200566
21). 200702
Side Panel, High
Drive Chain
Drive Sprocket
Driven Sprocket
22). 200703
23). 200547
24). 200712
25). 140027
26). 400846
Bearings
Drive Motor 28). 400899
2
1
4
4
1
1
1
1
1
1
1
1
1
2
DESCRIPTION
Fan Motor
Control Box Cover
Idler Shaft
Crumb Tray
Infinite Switch
Speed Control
Reset Switch
Knob, Infinite Switch
Knob, Speed control/Power Saver
Power Saver Switch
Leg, 4" Plastic
Cord/Plug Set
1 Heat Shutter (H model only)
REVISED 12/6/2005 RMS
Parts continued on page 14
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
PARTS LIST /EXPLODED VIEW MODEL TX710(H), 208, 240 VOLT
1.
PAGE 14
3
..
28.
4.
2.
5.
17.
16.
18.
29.
11.
9.
6.
21.
22.
19.
20.
13.
14.
12.
25.
10.
8.
7.
27.
23.
15.
24.
26.
PART No. QTY DESCRIPTION
1).
2).
400821
199105
2a). 199106
2)
2a)
3).
4).
5).
6).
209197
209193
401276
160004
400925
416789
4
4
4
1
1
4
4
1
2
Cover, Top
Heater Tube, 208V TX710
Heater Tube, 240V TX710
Heater Tube, 208V TX710H 20). 115146
Heater Tube, 240V TX710H 21). 200702
Retainer, Heater Tube
Conveyor Belt
22).
24).
200703
200712
Back Panel, High
Side Panel, High (H)
PART No. QTY. DESCRIPTION
17). 100511
18). 200538
19). 118040
1
2
1
Crumb Tray
Infinite Switch, 208/240 Volt
Speed control, 208/240 Volt
25). 140025
26). 400825
1
2
1
4
1
1
Reset/High Limit
Knob, Infinite Switch
Knob, Speed Cont'l/ Pwr Saver
Leg, 4" Plastic
Power Supply Cord, 208/240 V
Toast Chute
27). 401131 1 Extension
8).
9).
200645
200645
1
2
Drive Sprocket
Driven Sprocket
10). 202900 1 Drive
11). 112261 2 Bearings,
12). 200509
13a). 200560
14). 401462
1
1
1
Drive Motor, 208/240 Volt
Fan Motor, 208/240 Volt
Control Box Cover
15). 200562 1 Fan
16). 202904 1 Idler
28). 400891
29). 200693
1
2
Heat Shutter (H Model Only)
Idler Bushing
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
WIRING DIAGRAM FOR MODEL T710(H & TW) 120 VOLT
TX710(H) 120 VOLT
WIRE DIAGRAM
FOR MODEL T710(H), TX710(H) - 120 VOLT
PAGE 15
PLUG CONFIGURATION
NEMA 5-15P
120 VOLT
REV. 9/15/98 MJC
H:\TOASTERS\T710\
120VAC/WIRDIAG\
T710SCM.DS4
REV. 9/18/98 MJC
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
WIRING DIAGRAM FOR MODEL T710(H & TW) 208, 240 VOLT
TX710(H) 208, 240 VOLT
T714(H) 208, 240 VOLT (3.2 KW)
PAGE 16
BLUE
220/240
VAC
WHITE
208 VAC
BLACK
COMMON
PLUG CONFIGURATION
NEMA 6-20P
208/240 VOLT
REV. 9/15/98 MJC
H:\TOASTERS\T710\
208VAC\WIRDIAG\
T710SCM.DS4
REV. 9/18/98 MJC
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
WIRING DIAGRAM FOR MODEL T714(H & TW) TX714, 3.6 kW 208, 240 VOLTS, WIRED
PARELLEL
PLUG CONFIGURATION
NEMA 6-30P
REV. 1/28/97 MJC
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
WIRING DIAGRAM FOR MODEL B710(H), 120 VOLT
Top Heat
PAGE 18
Control
M
Bottom Heat
Top
Heat
H2
L2
H1
L1
H2
L2
H1 Bottom
Heat
L1
1 2
3 4
L1 L2
GROUND
M
Plug Configuration
NEMA 5-20P
120V
REV. 7/31/97 MJC
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
WIRING DIAGRAM FOR MODEL S710(H), 120, 208, 240 VOLT
MODEL TX710 WITH OUT POWER SAVER 120, 208, 240 VOLT
PAGE 19
PLUG CONFIGURATION
NEMA 5-15P NEMA 6-20P
120 VOLT 208/240 VOLT
REV. 1/28/97 MJC
OPERATOR'S MANUAL
HOLMAN CONVEYOR TOASTERS
MODELS T710(H, TW, TX) T714(H, TW, TX) S710(H) S714(H) B710H
WIRING DIAGRAM FOR MODEL S714(H) 208, 240 VOLT
PLUG CONFIGURATION
NEMA 6-30P
REV. 1/28/97 MJC
advertisement