Turbo Air TAS-18EHN User manual

Add to my manuals
2 Pages

advertisement

Turbo Air TAS-18EHN User manual | Manualzz

4184 E. Conant St.

Long Beach, CA 90808

Tel. 888-900-1002

Fax. 310-900-1088 www.turboairinc.net

Project :

Model # :

Item # :

Approval :

Qty :

Model : TAS-24EHN - TAS-24EHN/O

208~230V / 60HZ (Evaporator Unit & Condensing Unit) HEAT PUMP

Low Ambient Operation

The unit can set for cooling even when the outdoor temperature drops to 5 degrees F. This is ideal for locations that require cooling even in winter.

Automatic Restart Function after Power Failure

This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.

Quiet Operation

The DC Inverter Air Conditioner uses a twin rotary compressor.

Compared to the conventional single cylinder type, the twin rotary compressor dramatically reduces vibration and noise during operation, thus ensuring quiet operation.

Energy-Saving Operation

The DC Inverter Air Conditioner affords continuous operation, while it adjusts capacity according to the room temperature. The accurate sensing of cooling or heating loads prevents frequent changes in capacity and ensures efficient, economical operation.

R-410A

ODP(Ozone Depletion Potential) = 0 of hfc refrigerant is used.

Anti-Mold Filter

Filter is treated with anti-mold chemicals to prevent mold or bacteria from occurring.

Air Sweep Control (Selected model)

The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.

Hot Start Heating System

Right from the start, air is warm and comfortable. The Hot Start

Heating System prevents any cool blast at the beginning while the heat pump is warming up. (Heat pump unit only)

Rapid Cooling and Heating

Since the DC Inverter Air Conditioner has efficient rapid heating and cooling capacity produced by variable compressor rotation speed, it ensures quicker control of room temperatures than conventional air conditioners.

Electric Refrigerant Control Valve

The circulation volume of the refrigerant is controlled by a pulse type electric control valve.

Louver Control

Louver can be manually set to the desired angle by remote control.

1 YEAR

(U.S.A only)

Ver.201405

DC Inverter Wall Mount Unit

LOCATION: JOB NAME:

PURCHASER:

ENGINEER:

SUBMITTED TO: FOR: REFERENCE APPROVAL

SPECIFICATIONS

SEER

EER

HSPF

Voltage

Breaker Size (A)

RLA Cool/Heat (A)

Operating Ambient Temperature Range for Cooling

Operating Ambient Temperature Range for Heating

Indoor Unit

Airlow Hi/Medium/Low Speed (CFM)

Noise Level Hi Speed (Db)

Width (Inches)

Depth (Inches)

Height (Inches)

Unit Weight (lbs)

Outdoor Unit

Noise Level (dB)

Width (Inches)

Depth (Inches)

Height (Inches)

Unit Weight (lbs)

Line Sets

Refrigerant

Pipe Size

Maximum Length

Maximum Vertical

Factory Charge for (Ft)

Additional Charge (Oz/Ft)

Controls

Control Method

Communication Control Voltage

Certification

Safety

Performance

*All specification subject to change without notice.

TAS-24EHN & TAS-24EHN/O

19

12.5

9

208-230V/60HZ/1PHASE

25

8.4/9.1

5'F - 125'F

5'F - 125'F

1450/1300/1050

50

48.2

16.53

13.38

40.79

60

41.06

15.55

36.02

130.07

R410A

3/8" 5/8"

82

33

ETL

ARI 3081766

CONSTRUCTION

Wired & wireless remote control with temp sensor in indoor unit

208-230V

Toll Free

: 888-900-1002

1 YEAR

(U.S.A only)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement