Installation guide | Cisco Systems 3620 Network Router User Manual

C H A P T E R
4
Installation on Cisco 3660 Routers
This chapter describes how to install a NEBS Level 3/ETSI kit on your Cisco 3660 router and contains
the following sections:
Note
•
Attaching the 23-Inch Rack-Mounting Brackets, page 4-1
•
Installing the Ground Lug, page 4-4
•
Making Network Connections, page 4-6
•
Installing the Alarm Terminal Block, page 4-7
If you have yet to install your Cisco 3600 series router, see the publication Cisco 3600 Series
Hardware Installation Guide.
You can access this document online and on the documentation CD-ROM that you received with
your router at: Cisco Product Documentation > Access Servers and Access Routers > Modular
Access Routers > Cisco 3600 Series Routers > Hardware installation documents for Cisco 3600
series
Attaching the 23-Inch Rack-Mounting Brackets
The NEBS kit for Cisco 3660 routers comes with rack-mount brackets for installing the Cisco 3600
series routers in 23-inch or 24-inch racks.
Attach the mounting brackets to the chassis as shown in Figure 4-1, Figure 4-2, or Figure 4-3, using the
screws provided. Attach the second bracket to the opposite side of the chassis.
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
78-5450-06 B0
4-1
Chapter 4
Installation on Cisco 3660 Routers
Attaching the 23-Inch Rack-Mounting Brackets
23-Inch Bracket Attachment to Cisco 3660 Chassis—Front Panel Forward
Note: The second bracket attaches to the other side of the chassis.
23-Inch Bracket Attachment to Cisco 3660 Chassis—Rear Panel Forward
17330
Figure 4-2
26322
Figure 4-1
Note: The second bracket attaches to the other side of the chassis.
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
4-2
78-5450-06 B0
Chapter 4
Installation on Cisco 3660 Routers
Installing the Cable Management Bracket
23-Inch Bracket Attachment to Cisco 3660 Chassis—Center-Mount, Rear Panel Forward
Note: The second bracket attaches to the other side of the chassis.
The brackets can also be installed with the front panel forward.
22657
Figure 4-3
Installing the Cable Management Bracket
The NEBS kit for Cisco 3660 routers comes with a cable management bracket for managing cables for
the Cisco 3600 series router. (See Figure 4-4.)
Figure 4-4
Cable Management Bracket to Cisco 3660 Chassis
Attach the cable management bracket to the chassis as shown in Figure 4-5, using the screws provided.
Wrap cables to the management bracket as shown in Figure 4-6.
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
78-5450-06 B0
4-3
Chapter 4
Installation on Cisco 3660 Routers
Installing the Ground Lug
Cable Management Bracket on the Cisco 3660 Chassis
TD
V1
TC
V0
RD
HSSI 0
0
SEE MANUAL BEFORE INSTALLATION
RC
1
HIGH SPEED SERIAL
1HSSI
IN USE
VIC
FXS
IN USE
VOICE
2V
1
0
FDX
LINK
100Mbps
FDX
LINK
100Mbps
VCC OK
SYSTEM
LB/CN
Figure 4-5
EN
EN
ETHERNET
4E
SERIAL
4T
ETH 3
SERIAL 0
SERIAL 1
SERIAL 2
SERIAL 3
ETH 2
ETH 1
ETH 0
0
3 2 1
LINK
EN
CN/LP RXC
Figure 4-6
RXD
TXC
TXD
CN/LP RXC
RXD
TXC
TXD
CN/LP RXC
RXD
TXC
TXD
CN/LP RXC
RXD
TXC
TXD
72339
ACT
EN
Wrapping Cables to the Management Bracket on the Cisco 3660 Chassis
Installing the Ground Lug
Follow this procedure to attach the ground lug to your router chassis:
Step 1
Turn OFF power to the router. However, to channel ESD voltages to ground, do not unplug the power
cable. Remove all network interface cables, including telephone cables, from the rear panel.
The following warning applies to routers that use a DC power supply:
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
4-4
78-5450-06 B0
Chapter 4
Installation on Cisco 3660 Routers
Installing the Ground Lug
Warning
Before performing any of the following procedures, ensure that power is removed from the DC
circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services
the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the
circuit breaker in the OFF position. To see translations of the warnings that appear in this
publication, refer to the Regulatory Compliance and Safety Information document that
accompanied this device.
Step 2
Strip one end of the 6-AWG wire to expose approximately 0.75 in. (20 mm).
Step 3
Crimp the ground lug around the wire. (See Figure 4-7.)
Crimping the Lug Around the Wire
10360
Figure 4-7
Step 4
Use the number 2 Phillips screwdriver to fasten the ground lug to the Cisco 3660 router chassis. (See
Figure 4-8.)
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
78-5450-06 B0
4-5
Chapter 4
Installation on Cisco 3660 Routers
Making Network Connections
Figure 4-8
Ground Lug Fastened to Cisco 3660 Chassis
VCC OK
SYSTEM
FDX
LINK
100Mbps
FDX
LINK
100Mbps
1
0
22659
SEE MANUAL BEFORE INSTALLATION 0
TC
H
TD
EN
RC
LB/CN
V0
RD
V1
1
HIGH SPEED SERIAL
1HSSI
IN USE
VIC
FXS
IN USE
VOICE
2V
SERIAL
4T
ETHERNET
4E
SERIAL 3
SERIAL 2
SERIAL 1
SERIAL 0
ETH 3
ETH 2
ETH 1
3 2 1
CN/LP RXC
0
ETH 0
LINK
RXD
TXC
TXD
CN/LP RXC
RXD
TXC
TXD
CN/LP RXC
EN
RXD
TXC
TXD
CN/LP RXC
RXD
TXC
ACT
TXD
Ground lug
Step 5
Connect the other end of the ground lug wire to a grounding point at your site.
Making Network Connections
Note
If you still need to install network modules or WAN interface cards, you can do so now. For
instructions, see these publications: Cisco 3600 Series Hardware Installation Guide, Cisco Network
Modules Hardware Installation Guide, Cisco WAN Interface Cards Hardware Installation Guide.
You can access these documents online and on the documentation CD-ROM that you received with
your router at: Cisco Product Documentation > Access Servers and Access Routers > Modular
Access Routers > Cisco 3600 Series Routers > Hardware installation documents for Cisco 3600
series
Reinstall network cables and turn ON power to the router.
Note
Caution
The shielded cables in your NEBS/ETSI kit replace the cables originally shipped with your router.
NEBS/ETSI Intrabuilding Lightning Requirement
This equipment is suitable for connection to intrabuilding or nonexposed wiring or cabling only. This
cabling must be shielded.
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
4-6
78-5450-06 B0
Chapter 4
Installation on Cisco 3660 Routers
Installing the Alarm Terminal Block
The following warning applies to routers that use a DC power supply:
Warning
After wiring the DC power supply, remove the tape from the circuit breaker switch handle and
reinstate power by moving the handle of the circuit breaker to the ON position. To see translations
of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety
Information document that accompanied this device.
Installing the Alarm Terminal Block
The alarm port on the Cisco 3660 rear panel (see Figure 4-9) provides relay outputs to connect the router
to a remote alarm.
Figure 4-9
Alarm Port on the Cisco 3660 Router
VCC OK
SYSTEM
FDX
LINK
100Mbps
NO P NC
FDX
LINK
100Mbps
1
0
22660
SEE MANUAL BEFORE INSTALLATION 0
TC
H
TD
EN
RC
LB/CN
V0
RD
V1
1
HIGH SPEED SERIAL
1HSSI
IN USE
VIC
FXS
IN USE
VOICE
2V
SERIAL
4T
ETHERNET
4E
SERIAL 3
SERIAL 2
SERIAL 1
SERIAL 0
ETH 3
ETH 2
ETH 1
3 2 1
CN/LP RXC
Alarm port
0
ETH 0
LINK
RXD
TXC
TXD
CN/LP RXC
RXD
TXC
TXD
CN/LP RXC
Slot 6
Slot 4
Slot 2
EN
RXD
TXC
TXD
CN/LP RXC
RXD
TXC
ACT
TXD
Slot 0
Slot 5
Slot 3
Slot 1
The terminals are described in Table 4-1. In order to operate the alarm port, wire the P terminal and one
of the other terminals (NO and NC).
Table 4-1
Alarm Terminal Block Connections
Terminal
Meaning
P
Primary—This pin is connected to the common contact of the alarm relay.
NO
Normally open—This pin is connected to the “normally open” contact of the alarm
relay, and is disconnected from the primary pin during normal system operation.
During an alarm condition it is connected to the primary pin by the alarm relay.
NC
Normally closed—This pin is connected to the “normally closed” contact of the
alarm relay, and is connected to the primary pin during normal system operation.
During an alarm condition it is disconnected from the primary pin by the alarm relay.
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
78-5450-06 B0
4-7
Chapter 4
Installation on Cisco 3660 Routers
Installing the Alarm Terminal Block
Follow this procedure to install the alarm terminal block (see Figure 4-10) in the Cisco 3660 router alarm
port:
Step 1
Turn OFF power to the router. However, to channel ESD voltages to ground, do not unplug the power
cable.
Step 2
Use 12- or 14-AWG copper wires to connect DC-input power to the terminal blocks.
Step 3
Strip the wire shielding so that approximately 0.38 in. (9.7 mm) of each wire is exposed.
22661
Figure 4-10 Alarm Terminal Block
NO P NC
Step 4
Step 5
Press the orange-colored release and insert a wire into a receptacle of the alarm terminal block. Two of
the three receptacles must have wires installed (see Table 4-1). The spring-loaded connector retains the
wires.
Note
Always wire the P terminal and one of the other (NO and NC) terminals.
Note
To remove wires, press the orange-colored release next to each receptacle.
Plug the alarm terminal block into the alarm port on the Cisco 3660 chassis. (See Figure 4-11.)
Note
Connect the alarm terminal block to either an AC power source rated maximum 25 VAC and
5A current rating, or a DC power source rated maximum 30V and 5A current rating.
VCC OK
SYSTEM
Step 6
FDX
LINK
100Mbps
FDX
LINK
100Mbps
1
0
22861
Figure 4-11 Connecting the Alarm Terminal Block to the Alarm Port
Reinstall network cables, and turn ON power to the router.
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
4-8
78-5450-06 B0
Download PDF

advertising